Loading...
HomeMy WebLinkAboutFile Documents.506 E Main St.0054.2019 (29).ACBK ELEMENT ENVIRONMENTAL | Courthouse 051519 North & West Hall 189 County Road 135 Glenwood Springs, CO 81601 (970) 274-3139 Final Clearance Letter For Pitkin County Courthouse Main Level Hall on North Wing and West Wing 506 E. Main St. Aspen, CO 81611 May 15th, 2019 Prepared for Pitkin County Courthouse 506 E. Main St. Aspen, CO 81611 Element Environmental Project Number Courthouse 051519 North & West Hall Prepared By: Joshua Johnson CDPHE Air Monitoring Specialist #18401 CDPHE Asbestos Consulting Firm #21640 09/03/2019 ELEMENT ENVIRONMENTAL | Courthouse 051519 North & West Hall Element Environmental Date: 05/15/2019 189 County Rd. 135 Glenwood Springs, CO 81601 (970) 274-3139 josh@elementconsults.com Client: Pitkin County Courthouse Dear Ms. Jodi Smith, I am pleased to offer you this report for work performed at the reference site. On May 15th, 2019 Mr. Joshua Johnson with Element Environmental performed final clearances of at 506 E. Main St., Aspen, CO of the Main Level Hallway in the North Wing and West Wing. The final clearances consist of a visual inspection for dust and debris and ambient air sampling. The clearance consisted of 1 containment. This was an abatement to remove ACM 9 x 9 tiles. Any material that is remaining must be assumed to be ACM material until it is tested. Mr. Joshua Johnson CDPHE AMS #18401 performed a visual inspection. After the visual inspection was complete, air samples were taken of each of the work areas. Five samples were taken from the work area. The air samples were analyzed by PCM (Phase Contrast Microscopy) per the NIOSH 7400 method. All samples must below 0.01 f/cc in order to pass the air clearance. All samples were below the limit amount. Per Colorado Reg 8 Part B guidelines. The work area is now clear for occupancy or normal work to resume. Any suspect asbestos containing materials (ACM) remaining should be assumed to contain asbestos unless they are properly tested and analyzed by a CDPHE accredited inspector. All work performed MUST follow appropriate EPA, CDPHE, OSHA, and local government guidelines to protect the employees, occupants, and the environment. _______________________________________________ Joshua Johnson Air Monitoring Specialist# 18401 09/03/2019 ELEMENT ENVIRONMENTAL | Courthouse 051519 North & West Hall 09/03/2019 ELEMENT ENVIRONMENTAL | Courthouse 051519 North & West Hall 09/03/2019 ELEMENT ENVIRONMENTAL | Courthouse 051519 North & West Hall 09/03/2019