HomeMy WebLinkAboutFile Documents.120 S Spring St.0326.2017 (18).ARBKThe City of Aspen
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
03/09/2018
justinh
01/29/2018
2
x
2 Bedrooms, 2 3/4 baths, garage, mechanical, laundry
2 bedrooms, 1 full bath, 1 3/4 bath, 1 1/2 bath
kitchen, living room, 1/2 bath
JH 3/9/18
4 1
3 2
0326.2017.ARBK
03/09/2018
03/09/2018
justinh
01/29/2018
COMMERCIAL REFERENCES FROM 2015 IBC
EU = enclosed usable space under stairs shall be 1-hr construction or stair
enclosure rating. No access from stair enclosure.1011.7.3
SG = safety glazing required sec 2406
V = ventilation required, including from bathrooms. sec 1203.1, IMC 402 & 403
GR = guards, 42” min ht, 4” max opening sec 1015
HR = handrails 34”-38” ht sec 1014
AS = risers shall be solid in accessible egress stairs sec 1011.5.5.3
DS = Draft stopping / fire blocking 718
RD = Roof drainage 1503.4
STC = Sound transmission class not less than 50 at dwelling separations, sec
1207
PD = protect against decay, sec 2304.12
REFERENCES FROM 2015 IMC
AS = access and service space for maintenance req’d, sec 306
MA = kitchen hood make up air required, sec 508
ET = exhausts terminate 3’ from prop line and openings, 10’ from intakes,
501.3.1
IT= intake openings 10’ from lot line & contaminant sources (vents, streets),
401.4
D = fasten and seal all ductwork per 603.9
REFERENCES FROM 2015 IFGC
CA = combustion air not taken from bathrooms or storage, sec 303.3
REFERENCES FROM 2015 IECC
F = new or replacement glazing U factors may not exceed:
Fixed fenestration: U 0.29
Operable fenestration: U 0.37
Entrance doors: U 0.77
-Must have NFRC label or ASHRAE calcs, sec C402.4
REFERENCES FROM 2014 NEC
EP = electric panel ‘happy space’ 30”x36”x78”, not in storage, sec 110.26
SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
01/29/2018
0326.2017.ARBK 1/29/18
x
x
x
x
x
x
7003.75
325
325
321
321
1616.25
3150
10775
100
434
jb 1/29
JH 3/9/18
JH 3/9/18
tk 1/31
sw 4/6
pm 3/12
3/12 dr
DAM 4/16/18