Loading...
HomeMy WebLinkAboutFile Documents.63 Smuggler Grove Rd.0086.2019 (15).ARBKThe City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK S K PEIGHTAL ENGINEERS Ltd STRUCTURAL CONSULTANTS 17055 2019.04.16 Letter PO Box 410 • Basalt, CO • 81621 • 970.927.9510 • skpe.structural@gmail.com MEMORANDUM To: Aspen Building Department c/o Poss Architecture + Planning Tony Major 605 East Main Street Aspen, Colorado 81611 From: Adrienne Prosser, PE Date: 16 April 2019 Re: Remodel 63 Smuggler Grove Aspen, Colorado 81611 My office has been working closely with Poss Architecture + Planning to provide professional engineering services for the above referenced project. It is understood that a skylight has been added to the architectural design. This glazing element will be located directly above the new elevator shaft. The skylight will sit above the primary roof structure; therefore, the existing, curved steel beams will not require modification to accommodate this new roof penetration. The secondary, ladder framed rafters can be removed with minimal impact to the roof structure, which will be reviewed, and structural clarification provided as required. Throughout the remodel process, including the installation of the skylight, SK Peightal Engineers is in agreement to provide the following services: 1. Observation of existing structure during demolition phase. 2. Follow-up with Field Reports to help define critical elements if applicable. 3. Design and Construction Documents for any additional structural work. 4. Observations during new structural construction with Field Reports. Please feel to contact my office directly with any additional questions or concerns regarding this project. 16 April '19 04/18/2019 63 Smuggler Grove Aspen, Aspen CO Permit Number: 0049.2018.ARBK Change Order Description: Landscape: Move entry walk west 12”; no change to pervious/impervious areas. Architectural: 1. Upper level deck: Reductions in deck areas have been made to retain a portion of the upper level deck including removal of the master bedroom deck and reductions in the overall floor area as described below. a. Floor areas and calculations have been revised as shown on revised sheet G-102. b. Revisions to the upper level stair and landing result in reduced floor area as shown on sheet A-102 and A-103. c. Interior remodel and Fire areas have been revised per sheets G-103 and G-104. 2. Upper level Stair: The upper level stair has been revised to a spiral stair in lieu of the scissor stair previously shown. The existing spiral stair is to be augmented and re-used. The upper level floor is to be removed and replaced as shown on sheets AD-103, A-103, A-107, A-302 and new spiral stair details sheet A-401. 3. Added dormer: The added dormer and related demolition has been omitted. a. The existing roof will remain as shown on sheets AD-202, A-201 - A-203, A-301 - A-303. b. Add sheet A-304 c. Omit dormer details; sheet A-401 d. Roof and wall area calculations have been revised as shown on sheets G-105 and G-106. 4. Revised lower level stair: The lower level stair detailing has been revised and simplified as shown on sheet A-402. 5. Elevator and hoistway: a. The elevator hoistway enclosure has been reduced in size as shown on sheets A-100 – A- 102. The overall opening in the floor has not changed. b. A skylight has been added to the existing roof above the elevator as shown on sheets A- 103, A-104, A107, AD-202, A-202, A-203 and A-302. c. Roof demolition calculations have been revised as shown on sheet G-105. 6. Plan revisions: a. Lower Level: i. Bedroom #5 (001): Entrance alcove has been removed ii. Bath #5 (002): Redesigned iii. Bar area (003): Revised layout iv. Storage (105): Added stack washer/dryer b. Ground Level: i. Entry (100): revised entrance doors. ii. Bath #2 (104): revised closet & shower enclosure. iii. Remove & replace existing glass block windows w. new to match existing 04/18/2019 iv. Bedroom #4 (109): Replaced existing window c. Main Level: i. Living Room (201): Remove and replace fireplace stone veneer ii. Hall (203): Revise and reuse existing spiral stair to crow’s nest iii. Kitchen (209): Replace several cabinets & countertop iv. Powder Room (208): Redesigned v. Master Bedroom (204): Covert deck into canopy, provide barrier at doors vi. Master Bath (205): Replace door, added new shower controls d. Upper Level: i. Replaced upper floor and revised stair as described above ii. Reduced size of exterior deck to comply with floor area requirements as described above e. Roof: i. Reduced size of exterior deck to comply with floor area requirements as described above ii. Added skylight above elevator as described above Structural: 1. Revise framing and support for revised stair as described above 2. Revise elevator hoistway as described above 3. Revise decks as described above Mechanical: 1. Add new air conditioning system End of Description 04/18/2019 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT APPLICATION CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 PROPERTY INFORMATION ___________________________________ _________ ___________________________ ______________ ______________ ________________________________________ _________________________ _______________ __________________________________ ________________________ _______________ __________________________________ CommericalDƵůƟͲ&ĂŵŝůLJ^ŝŶŐůĞ&ĂŵŝůLJ Use of Building Class of Work NewĚĚŝƟŽŶůƚĞƌĂƟŽŶRepair ________ YesNo Will there be ĂŶLJƌŽŽĨͬǁĂůůƉĞŶĞƚƌĂƟŽŶƐ͍ NOTICE: This permit becomes null and void if work ŽƌĐŽŶƐƚƌƵĐƟŽŶĂƵƚŚŽƌŝnjĞĚŝƐŶŽƚĐŽŵŵĞŶĐĞĚǁŝƚŚŝŶϭϴϬĚĂLJƐ͕ŽƌŝĨĐŽŶƐƚƌƵĐƟŽŶŽƌǁŽƌŬŝƐƐƵƐƉĞŶĚĞĚŽƌĂďĂŶĚŽŶĞĚĨŽƌĂƉĞƌŝŽĚŽĨϭϴϬĚĂLJƐĂƚĂŶLJƟŵĞĂŌĞƌ work is commenced. _______________ _______________ _______________ _______________ _______________ _______________ _______________ _______________ _______________ PROJECTVALUATION SQ FT OF BUILDING WORK AREA UNIT SQ FT SQ FT OF SOILDISTURBANCE BUILDING FOOTPRINT LOT SIZE(SQ FT) PROJECT DETAILS (READ DEFINITIONS BELOW) DŝdžĞĚͲhƐĞ IFFR Tenant FinishĞŵŽůŝƟŽŶ Change Order ________ ADDRESS UNIT #PARCEL ID # BLOCK TRACT OR SUBDIVISIONLOT DESCRIPTION OF WORK IN DETAIL Building Review Building Permit Fee Parks Impact Engineering Review Zoning Review (50%) School Lands ĞĚŝĐĂƟŽŶ Zoning Review (50%) CMP (50%)TDM Impact ŶĞƌŐLJŽĚĞ Review REMP WĂLJŵĞŶƚ Pedestrian ŵĞŶŝƚLJ CMP (50%) GIS Housing Cash in Lieu Parks Review ŝƚLJhƐĞ Tax Water Tap hƟůŝƚLJZĞǀŝĞǁ ŽƵŶƚLJhƐĞ Tax ^ĂŶŝƚĂƟŽŶ SUBMITTAL FEES ISSUANCE FEES APPROVALS ISSUANCE FEES BEST CONTACTNAME CELL EMAIL OWNER NAME CELL EMAIL ____Toilets, Bidets ____Bathtubͺͺͺͺ>ĂǀĂƚŽƌLJ;tĂƐŚĂƐŝŶͿ ____Shower ____Kitchen Sink (+Disposal) ____Dishwasherͺͺͺͺ>ĂƵŶĚƌLJĂƌ͕hƟůŝƚLJ^ŝŶŬ ____Clothes Washer ____Floor Sink ____Floor Drain ____Water Heater (Pan Req) ____# Gas Outlets ____Water Treatment ____Other_________ Fixture Counts Important Review Triggers PC Zoning HPC Building Fire Engineering CMP Water Stormwater ^ĂŶŝƚĂƟŽŶ Env. Health Parks Landscape ĸĐŝĞŶĐLJ Approved To Issue Issuance Date ApprovedReviewingDepartment Reviewer^ŝŐŶͲKī NEW SQ FT WƌŽũĞĐƚsĂůƵĂƟŽŶ͗ŽƐƚŽĨƉƌŽũĞĐƚĂƐĚĞĮŶĞĚŝŶsĂůƵĂƟŽŶīĂĚĂǀŝƚ͘^Ƌ&ƚŽĨƵŝůĚŝŶŐtŽƌŬƌĞĂ͗dŽƚĂůƐƋƵĂƌĞĨŽŽƚĂŐĞŽĨŝŶƚĞƌŝŽƌĂƌĞĂƵŶĚĞƌŐŽŝŶŐĐŚĂŶŐĞŽƌƌĞĐŽŶĮŐƵƌĂƟŽŶ͘hŶŝƚ^Ƌ&ƚ͗'ƌŽƐƐƐƋƵĂƌĞĨŽŽƚĂŐĞ͕ŶŽƚ&Z͕ŽĨƉĞƌŵŝƩĞĚƵŶŝƚ͘>Žƚ^ŝnjĞ͗dŽƚĂůƐƵƌǀĞLJĞĚƐƋƵĂƌĞĨŽŽƚĂŐĞŽĨƉƌŽƉĞƌƚLJ͘^Ƌ&ƚŽĨ^ŽŝůŝƐƚƵƌďĂŶĐĞ͗ Exterior area of the lot where the ground is disturbedEĞǁ^Ƌ&ƚ͗dŽƚĂůĂĚĚĞĚƐƋƵĂƌĞĨŽŽƚĂŐĞĨŽƌĂĚĚŝƟŽŶƐƚŽŶĞƚůŝǀĂďůĞŽƌŶĞƚůĞĂƐĂďůĞƐƉĂĐĞ͘ƵŝůĚŝŶŐ&ŽŽƚƉƌŝŶƚ͗'ƌĂĚĞŇŽŽƌƐƋƵĂƌĞĨŽŽƚĂŐĞŽĨƚŚĞƉĞƌŵŝƩĞĚƐƚƌƵĐƚƵƌĞ͘,ĂƌĚƐĐĂƉĞƌĞĂ͗Square footage of impervious lot surface.ŽŶĞŝƐƚƌŝĐƚ͗hŶĚĞƌůLJŝŶŐnjŽŶĞĚŝƐƚƌŝĐƚŽĨƉĞƌŵŝƩĞĚƉĂƌĐĞů͘ January 2019 DATE:___________ MASTER PERMIT:______________________ PERMIT NUMBER:__________________________ __________________________________________________________________________________ __________________________________________________________________________________ HARDSCAPEAREA NeedsReview DE F I N I T I O N S ZONEDISTRICT Major Engineering Review • Projects involving less than 50% ŚĂƌĚƐĐĂƉĞĂƌĞĂĂŶĚǁŽƌŬĂīĞĐƟŶŐϳϱйŽƌŐƌĞĂƚĞƌŽĨƵŶŝƚƐƋŌ • Projects involving greater than 50% hardscape area and work ĂīĞĐƟŶŐϱϬйŽƌŐƌĞĂƚĞƌŽĨƵŶŝƚƐƋŌ • WƌŽũĞĐƚƐŝŶǀŽůǀŝŶŐϭ͕ϬϬϬнƐƋŌŽĨ soil disturbance area tĂƚĞƌĸĐŝĞŶƚ>ĂŶĚƐĐĂƉŝŶŐ • Projects that trigger a major engineering review • Projects involving interior ĂůƚĞƌĂƟŽŶƐĂīĞĐƟŶŐϱϬйŽƌŵŽƌĞŽĨĞdžŝƐŝƟŶŐŐƌŽƐƐƐƋƵĂƌĞĨŽŽƚĂŐĞ THIS SECTION MUST BE COMPLETED IN ITS ENTIRETY 04.17.2019 0049.2018.ARBK 63 Smuggler Grove, Aspen, CO 273718106004 4 East Meadow Subdivision DP Aspen LLC 516 624-1919 DBlumenfeld@BDG.net Kim Weil 970 925-4755 kweil@billposs.com change walls, delete dormer, add skylight, revise stair $2,100,000.00 8 5 11 3 1 1 2 2057.07 sf 6,107.60 sf gross 7,668 sf 2 800 sf 0 2021.81 sf 4 1 1 280 sf R-15A 04/18/2019 0086.2019.ARBK x jb 4/18/19 x x x x 25 BN 4/30/19 0 0 0 0 0 JF 5/1/19 TF 5/10/19 0086.2019.ARBK DP ASPEN LLC 63 SMUGGLER GROVE 273718106004 1 FIRE SPRINKLERS REQUIRED SMOKE ALARMS AND CARBON MONOXIDE DETECTORS REQUIRED THROUGHOUT DWELLING UNIT PER CITY OF ASPEN MUNICIPAL CODE 8.15