Loading...
HomeMy WebLinkAboutFile Documents.1039 E Cooper Ave.0049-2020-BCHO (16)The City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK READ THIS OR FAIL YOUR INSPECTION! Furred & Dropped Ceilings, Soffits, and Walls 20015 IBC 803.13 This applies to the attachment of finishes or furring to any assemblies that are required to be either fire-rated or non-combustible and is separate from the fire-rated assembly requirement. Walls, Ceilings & Soffits: If furred 1 ¾ inches or less, do one of the following: 4.Fill spaces with Class A material. 5.Fill spaces with inorganic or non-combustible material. 6.Fire block 8 feet in all directions. Walls: If set out (furred) greater than 1 ¾ inches, do one of the following: 4.Use a Class A finish material (such as drywall). 5.Use non-combustible framing. 6.Protect both sides with fire sprinklers. Ceilings & Soffits: If dropped (furred) greater than 1 ¾ inches: Framing members, hangers, and other assembly members must be non-combustible. You may not use wood. In Type III and V construction only, you may use fire retardant treated wood or non-combustible framing. 2015 IBC 601 Fire Resistive Requirements for Type of Construction: ____ Primary Structural Frame: ____hr (columns, beams, girders, etc) Exterior Bearing Walls: ____hr Interior Bearing Walls: ____hr Floors/Ceilings: ____hr Roof : ____hr Unless noted otherwise for occupancy separation or fire separation distance. VA 1 1 1 1 1 0049-2020-BCHO SHAPIRO GANT LLC 1039 E COOPER #20A 273707342040 09/04/2020 justinh RESIDENTIAL REFERENCES FROM 2015 IBC CV/CS = crawl space ventilation sec. 1203.4. 18” x 24” access required 1209.1 EE = emergency escape required sec 1030 EU = enclosed usable space under stairs shall be 1-hr construction or stair enclosure rating. No access from stair enclosure. ½” gypsum permitted for stairs inside a single dwelling unit. 1011.7.3. RV = roof and rafter ventilation required 1203.2 A = Attic Access 20” x 30” 1209.2 SA = smoke alarm (NFPA 72) required sec 907.2.11 CO = carbon monoxide detector req. per Aspen Municipal Code 8.15 SG = safety glazing required sec 2406 V = mechanical ventilation required sec 1203.1 & IMC 403 (bath fans and whole house ventilation) GR = guards, 42” min ht, 4” max opening. Guards within dwelling unit 36” min ht sec 1015 HR = handrails 34”-38” ht sec 1014 DS = Draft stopping / fire blocking 718 RD = Roof drainage 1503.4 STC = Sound transmission class not less than 50 at dwelling separations, sec 1207 SI = Stairway Illumination 1205.4 PD = protect against decay, sec 2304.12 REFERENCES FROM 2015 IMC DE = clothes dryer exhaust, sec 504. Makeup air req’d if over 200 CFM AS = access and service space for maintenance req’d, sec 306 MA = make up air required if hood exhausts greater than 400 CFM, sec 505.2 ET = exhausts terminate 3’ from prop line and openings, 10’ from intakes, 501.3.1 IT= intake openings 10’ from lot line & contaminant sources (vents, streets), 401.4 D = fasten and seal all ductwork per 603.9 REFERENCES FROM 2015 IFGC DV = direct vent req’d, sec 303.3 CA = combustion air not taken from bedrooms, bathrooms or storage sec 303.3 OD = outdoor appliances must be listed for outdoor use, sec 303.6 REFERENCES FROM 2015 IECC F = new or replacement fenestration shall not exceed 0.28 U-factor, NFRC label required, Ordinance 40, 2016 L = 75% of lamps in permanently installed lights must be high efficacy, sec R404.1 SE = Continuous air barrier required; all exterior joints, cracks, and holes to be caulked, gasketed, sealed, table R402.4.1.1 REFERENCES FROM 2014 NEC EP = electric panel 'happy space' 30"x36"x78", not in storage, sec 110.26 EXEMPTION FROM STREAM MARGIN REVIEW FOR 1039 E. Cooper Ave. Unit 20- Chateau Roaring Fork Address: 1039 E. Cooper Ave. Unit 20, Aspen, CO 81611- Chateau Roaring Fork Parcel ID: 2737-073-42-040 Zone District: Residential Multi-Family (R/MF) Unit 20 of the Chateau Roaring Fork is located in the Stream Margin Review Area as established in Section 26.435.040, Stream Margin Review, of the Aspen Land Use Code. Joel Shapiro, represented by Storm Designs, LTD, has submitted a land use application requesting to install an air-conditioning unit on the roof the building in which the unit is located. The project may qualify for an exemption if the following review criteria can be met: a)Does not add more than 10% of the existing floor area, or more than 25% of areas exempt from floor area; b)does not require the removal of any tree; c)no portion of the project will be any closer to high water line than existing development d)does not fall outside of an existing building envelope; and, e)will cause no increase to the amount of ground coverage within the 100-year flood plain. Staff has reviewed the scope of work and has determined that it will have no impact on the Stream Margin. There is no ground/site work proposed as part of project. No impacts to trees, vegetation, stormwater run-off, or water quality will occur. Lastly, the height of the A/C unit will be below 6-ft. as measured from the point of attachment. The scope of work identified above approved, subject to the following conditions: •If the scope of work is amended, a Stream Margin Review may be required. •This approval does not constitute a site-specific development plan and will not be issued a development order. The approval does not convey a vested right and the approved project is subject to any changes to the Land Use Code prior to building permit submittal. Approved: _________________________________ _______________ Kevin Rayes Date Planner, Community Development 9-8-2020 10/09/2020 sophiev