RE: 834 E Durant Residence Remodel – Aspen, Colorado
Dear Beth,
We understand the proposed remodel is an interior remodel to an existing residence. Once demolition can
begin, the interior wall and ceiling finishes shall be at least partially removed to allow observation of the existing
structural system. We shall be contacted to perform a site observation of the exposed structure to determine
the structural implications of the proposed remodel and any necessary structural revisions. This shall be done
prior to proceeding with the removal or modification of any framing members.
Thank you for engaging our firm for your project. Should you have any further questions regarding this matter,
please feel free to contact our office. We look forward to assisting you in completing your project.
Sincerely,
Evolve Structural Design LLC
Steven R. Edmiston, P.E., S.E.
Senior Engineer
11/06/2018
0189.2018.ARBK
7419.75
325
325
1284
1284
3486
1080
11415
x jb 7/13
x
x
x
x
x
434
07/13/2018
PM 07/18
BN 10/11/18
RMF
0
0
0
0
Existing ADU to be
extinguished with .38 FTE
affordable housingcertificate, Category 2
Existing ADU to be
extinguished with .38 FTEaffordable housing
certificate, Category 2
BM 11/13/18
BM 11/13/18
SW 11/2/18/PH 7/31/18`
07/13/2018
07/13/2018
X
Dwelling Separation Required - 2015 IBC
-708 Fire Partitions, 711 Horizontal Assemblies:
Walls and floor/ceilings separating dwelling units shall have a fire-resistance
rating of at least 1 hour. Walls shall extend from the top of the floor assembly
below to the underside of the floor or roof slab or deck above or to the
fire-resistance-rated floor/ceiling assembly above.
-714: Penetrations must be protected by a through-penetration firestop
system. Recessed fixtures shall not reduce the required fire resistance by use
of a listed fixture, a listed firehood, or a drywall assembly meeting the required
fire resistance. Exhaust fans require ceiling radiation damper.
-1207 Sound Transmission: Separating walls and floor/ceilings shall have an
STC rating of at least 50. Floor/ceilings shall have an IIC rating of at least 50.
2015 IBC 601 Fire Resistive Requirements for
Type of Construction: ____
Primary Structural Frame: ____hr
(columns, beams, girders, etc)
Exterior Bearing Walls: ____hr
Interior Bearing Walls: ____hr
Floors/Ceilings: ____hr
Roof : ____hr