HomeMy WebLinkAboutFile Documents.219 E Durant Ave.0094.2018 (27).ACBK09/15/2018
2500
78
Kitchen Storage, employee lockers
Commercial kitchen, dinning room and bar with 1 accessible unisex restroom and 1 standard unisex restroom
JH 5/2/19
The City of Aspen
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
0094.2018.ACBK
South Point Condo Assc
219 E Durant C5
2735 1310 6005
03/27/2019
NO EXTERIOR LIGHTING
IN SCOPE OF WORK. NO
CHANGES TO ROOF IN
SCOPE OF WORK,
INCLUDING ANY MEP
WORK.
09/15/2018
READ THIS OR FAIL YOUR INSPECTION!
Furred & Dropped Ceilings, Soffits, and Walls
20015 IBC 803.13
This applies to the attachment of finishes or furring to any
assemblies that are required to be either fire-rated or
non-combustible and is separate from the fire-rated
assembly requirement.
Walls, Ceilings & Soffits: If furred 1 ¾ inches or
less, do one of the following:
4.Fill spaces with Class A material.
5.Fill spaces with inorganic or non-combustible material.
6.Fire block 8 feet in all directions.
Walls: If set out (furred) greater than 1 ¾ inches,
do one of the following:
4.Use a Class A finish material (such as drywall).
5.Use non-combustible framing.
6.Protect both sides with fire sprinklers.
Ceilings & Soffits: If dropped (furred) greater
than 1 ¾ inches:
Framing members, hangers, and other assembly
members must be non-combustible. You may not
use wood.
In Type III and V construction only, you may use fire
retardant treated wood or non-combustible framing.
05/02/2019
justinh
COMcheck Software Version 4.1.1.0
Interior Lighting Compliance Certificate
Project Title:
2015 IECC
Project Type:Alteration
Construction Site:
219 East Durant Avenue
Unite C-5
Aspen, CO 81611
Owner/Agent:
Franz Thoma
Almresi Aspen
333 Bridge St.
Vail, CO 81657
f.thoma@thoma-essenerleben.de
Designer/Contractor:
IMEG Corporation
7600 East Orchard Road
Suite 250-S
Greenwood Village, CO 80111
Project Information
Energy Code:
Almresi - Aspen
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
(B X C)
1-Kitchen (Common Space Types:Food Preparation)250 1.21 302
2-Dining (Common Space Types:Dining Area - Bar Lounge/Leisure)1393 1.07 1491
1.00 39 (b)Allowance: Decorative Appearance / Fix. ID: K 90 (a)
3-Basement (Common Space Types:Storage >=50 - <=1000 sq.ft.)848 0.63 534
2366Total Allowed Watts =
(a)Area claimed must not exceed the illuminated area permitted for this allowance type.
(b)Allowance is (B x C) or the actual wattage of the fixtures given in Proposed Power section, whichever is less.
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
Kitchen ( Common Space Types:Food Preparation 250 sq.ft.)
LED 2: B: 2'X2': Other:1 6 36 216
LED 3: C: DOWN: Other:1 3 15 45
Dining ( Common Space Types:Dining Area - Bar Lounge/Leisure 1393 sq.ft.)
LED 3: C/D: DOWN/WW: Other:1 25 15 375
LED 5: F: LED PANELS: Other:1 3 20 60
LED 6: G: COVE: Other:1 59 3 189
LED 7: H: Other:1 20 3 60
LED 8: K: Other:1 3 13 39
Track lighting 1: J4/J8: TRACK: Wattage based on circuit breaker capacity (7 amps x 120
volts)
0 0 840 840
Track lighting 2: J12: TRACK: Wattage based on circuit breaker capacity (3 amps x 120 volts)0 0 360 360
Basement ( Common Space Types:Storage >=50 - <=1000 sq.ft. 848 sq.ft.)
LED 1: A: 1'X4': Other:1 9 19 171
2354Total Proposed Watts =
Project Title:
Data filename:
Almresi - Aspen
W:\01-Denver\2018.01.0077 Almresi Aspen\DWGS\Linked AutoCAD\ComCheck\IECC_Aspen.cck
02/25/19Report date:
61 ofPage03/17/2019
05/02/2019
justinh
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any
applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Interior Lighting PASSES
Project Title:
Data filename:
Almresi - Aspen
W:\01-Denver\2018.01.0077 Almresi Aspen\DWGS\Linked AutoCAD\ComCheck\IECC_Aspen.cck
02/25/19Report date:
62 ofPage
Ashlee Downham 02-26-2019
03/17/2019
05/02/2019
justinh
COMcheck Software Version 4.1.1.0
Mechanical Compliance Certificate
Project Title:
2015 IECC
Project Type:Alteration
Location:Aspen, Colorado
Climate Zone:7
Construction Site:
219 East Durant Avenue
Unite C-5
Aspen, CO 81611
Owner/Agent:
Franz Thoma
Almresi Aspen
333 Bridge St.
Vail, CO 81657
f.thoma@thoma-essenerleben.de
Designer/Contractor:
IMEG Corporation
7600 East Orchard Road
Suite 250-S
Greenwood Village, CO 80111
Project Information
Energy Code:
Almresi - Aspen
Mechanical Systems List
Quantity System Type & Description
Gas Storage Water Heater, Capacity: 400 gallons, Input Rating: 75 kBtu/h w/ Circulation Pump
No minimum efficiency requirement applies
1 ST-1:
Mechanical Compliance Statement
Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building
plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Name - Title Signature Date
Project Title:
Data filename:
Almresi - Aspen
C:\Temp Server\AA\IECC_Aspen.cck
02/21/19Report date:
61 ofPage
Mike J. Kissane - Senior Mechanical Designer 2-26-2019
03/17/2019
05/02/2019
justinh
FIRE
SPRINKLERS
REQUIRED
09/15/2018
9/14/18 0094.2018.ACBK
325
325
869.38
869.38
20289.61 31214.81
16232.86
4114.97
x jb 9/15
x
x
x
x
x
x
x
L/PD
SV 6/26/19
sw 4/30
JH 5/2/19
JH 5/2/19
PM 10/12/18
PH 6/20/19
NAT 5/14/19
DAM 7/1/19
The City of Aspen
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
Page 1 of 1
KL&A, Inc.
421 East 4th Street
Loveland, Colorado 80537
Telephone: (970) 667-2426
August 24, 2018
Tom Frye
Resort Design Architects
P.O. Box 1632
Lafayette, CA 94549
Re: Charthouse Lodge New Mechanical Units
Dear Mr. Frye,
The purpose of this letter is to state that we have reviewed the existing roof structure of the
building located at 219 East Durant Avenue in Aspen, CO for support of a make-up air unit. Our
review consisted of the following: review of the proposed mechanical equipment provided by
MKK Consulting Engineers, Inc., review of the existing structural drawings, and structural
calculations.
The existing roof structure is metal roof deck over steel framing supported on steel columns.
Existing roof members in the area of interest were W12x14 and W14x22 beams and W12X14 and
W16X26 girders. Existing beams were spanning 23’-6” and spaced at 6’-0” OC. Existing girders
spanned 18’-0”. The existing framing was checked for a roof dead load of 15psf, snow load of
75psf, and the additional mechanical loads. Based on our calculations and experience, the
existing roof structure is adequate to support the mechanical equipment provided it is located as
indicated by MKK.
This review was prepared in accordance with the standard of care for engineering practice. No
warranties are provided, either express or denied.
If you have any questions, please feel free to call.
Sincerely,
Prepared by: Sarah Early Reviewed by: Chris Kendall, PE
Design Engineer Principal
08/24/2018
09/15/2018
05/02/2019
justinh