Loading...
HomeMy WebLinkAboutFile Documents.232 E Main St.0132.2018 (101).ACBKThe City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK 12/05/2019 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 External Energy Use Approved RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:________________________________ REMP SHEET: __________________________ REVIEWED BY: _________________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: _________________ X 0132.2018.ACBK 11/26/19 0 0 0 N/A NT MANDATORY TESTING REQUIRED This construction project is required to comply with the 2015 International Energy Conservation Code. Commercial projects will require a blower door test performed in the manner complying with section C402.5 of the 2015 IECC. Maximum 0.40 cfm/sqft at 75 Pa. CORE AND SHELL PERMIT. TENANT FINISHES ON SEPARATE PERMITS Air Pollution Control Division – Indoor Environment Program – Asbestos/IAQ Air Unit 4300 Cherry Creek Drive South, APCD-IE-B1 Denver, Colorado 80246-1530 Phone: 303-692-3100 – Fax: 303-782-0278 E-mail: asbestos@state.co.us Colorado Department of Public Health and Environment Approval issued on: 10/3/2018 Record number: 142138 $60.00 Check number: 050508Notice Number: 18PI6713D For the location specified below: Conoco Gas Station 232 E. Main St. Aspen Pitkin County This notice has been issued to: Stutsman - Gerbaz Earthmoving Issued by: TS Asbestos Building Inspector: Inspection Date:06/06/2017 Fee Paid: 30376 Hwy 82 Snowmass, CO 81654 DEMOLITION APPROVAL NOTICE This approval notice is granted subject to Colorado Air Quality Control Commission Regulation No. 8, Part B, adopted December 21, 2007, and effective January 30, 2008 and the Colorado Air Pollution Prevention and Control Act C.R.S. (25-7-101 and 25-7-501 et seq). This notice signifies that the structure was inspected for asbestos, luminous exit signs (containing radioactive material), and Ozone-Depleting Refrigerants and the demolition contractor has properly notified the Colorado Department of Public Health and Environment pursuant to Regulation No. 8, Part B. THE ORIGINAL APPROVAL NOTICE MUST BE POSTED ON SITE AT ALL TIMES. Immediately notify the Asbestos/IAQ Unit of project modifications by fax (number above) or e-mail (address above) and the appropriate county health department by fax. Project modifications include changes in the scope of work or the scheduled work dates, etc. This demolition approval notice is valid beginning 3/1/2019. The actual scheduled work dates are from 3/1/2019 through 4/1/2019. Please note that certain asbestos-containing materials (ACM) may remain in the structure during demolition. Therefore, any demolition debris left behind after the completion of post- demolition site cleanup may constitute a "reason to know of asbestos-contaminated soil" at the site, subject to the requirements of Section 5.5 of the Solid Waste Regulations (6 CCR 1007-2, Part 1). As a contractor, you may be subject to other demolition licenses and permits, depending on the requirements of the county and municipality in which the work is being performed. The Colorado Department of Public Health and Environment, Air Pollution Control Division, strongly suggests that you check with county and municipal authorities in order to determine any other local building/permitting requirements that must be met. Brian Guzman 21876Cerification No.: 09/06/2019 SPECIAL INSPECTION REQUIRED: -Structural steel welding: Field & Shop -High strength bolting Special inspection is required per 2015 IBC section 1704. Inspector to verify that copy of agreement for inspection program to be on the job site prior to performing any inspections. A copy of all Special Inspector field reports to be on the job site for inspectors' review if requested. Failure to comply may result in denial of inspection. Code Editions Fire Sprinkler System Type Of Construction Fire Alarms Installed Required Special Inspections Energy Code Compliance Exterior Energy Use Total Approved On-Site Snowmelt________ Spa_______ Pool _________ Building Type/Occupancy Group COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DESCRIPTION FORM - IRC & IBC CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 BUILDING CODE INFORMATION 2015 IRC Existing?NFPA 13 NFPA 13 R High-Strength Bolting Epoxy Anchors Structual Steel Welding Permanent Micropiles Other _____________ Prescriptive Table UNIT DESCRIPTION AS PROPOSED # Stories Above Grade ______ # Stories Below Grade _______ Parking Spaces ______ Parking Spaces ______ Parking Spaces ______ # Bedrooms ______ # Full Baths ______ Deck Area ______ # 3/4 Baths ______ # 1/2 Baths ______ # Kitchens ______ # Wood Fireplaces ______ # Gas Appliances ______ # Gas Logs______ NFPA 13 D RESCheck UA Alternative Yes No One Family Two Family Townhouse Reviewed By: _____________________Date:__________ BUILDING ROOMS AND USES BY LEVEL AS PROPOSED (Include Mechanical & Storage) Basement ___________________________________________________________________________________ ___________________________________________________________________________________________ Main Level ________________________________________________________________ ____________________________________________________________________________________________ 2nd Floor ___________________________________________________________________________________ __________________________________________________________________________________________ 3rd Floor ___________________________________________________________________________________ ___________________________________________________________________________________________ Additional ___________________________________________________________________________________ ___________________________________________________________________________________________ Attached Garage Detached Garage Carport Is there an ADU? # Living Rooms_____# Kitchens _____# Full Baths _____# 3/4 Baths _____# 1/2 Baths _____# Bedrooms _____ # Other Rooms (List)____________ ADU BUILDING DESCRIPTION YesNo PERMIT NUMBER: _______________________________ (As Adopted and Amended) Other (Please Explain) _________________ _________________ VA VB IV IIIA IIIB IIA IIB IA IB Sprayed Fire-Resistants COMCheck UA Alternative (Existing + New) A__BB (A <50)F__H__I __ E R__S__ UM IRC IBC 2015 IBC (As Adopted and Amended) YesNo Required?YesNo Type January 2018 2015 IEBC (As Adopted and Amended) Other _____________ Gross Area of Building: __________ Gross Area of Unit: __________ Occupant Load: ___________ X X X X X X X X X X 828 SF X 5,709 SF N/A 57 TOTAL 2 0 0 0 0 0 0 0 0 0 0 00 575 SF N/A SPACE 'A' - FUTURE BUSINESS USE, SPACE 'B' - FUTURE BUSINESS USE, AND MECH. ROOM. SPACE 'B' - FUTURE BUSINESS USE N/A N/A 9-4-18 X 1 _____ 2 BRANCH BANK TENANT SPACE 12/26/2018 0132.2018.ACBK 3346sqft + 907sqft roof & gutter deicing 5353 54, subject to TI NT 1/13/20 01/ 1 3 / 2 0 2 0 nic k t FIRE SPRINKLERS REQUIRED 0 0 0 The State of Colorado has specific requirements that must be met during the removal and abandonment of Fuel Storage Tanks. All criterion must be met during tank removal including soil testing, observation, and disposal. 0132.2018.ACBK 232 EAST MAIN STREET LLC 232 EAST MAIN STREET 273707320008 These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK 03/06/2020 03/06/2020 03/06/2020 09/06/2019 0132.2018.ACBK 09/06/2019 Myers & Company Dennis Clemons 08/20/2019 09/06/2019 NICK THOMPSON 1/13/20 0132.2018.ACBK 01/ 1 3 / 2 0 2 0 nic k t COMcheck Software Version 4.1.1.0 Envelope Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit Date:1/2018 Vertical Glazing / Wall Area:29% Location:Aspen, Colorado Climate Zone:7 Construction Site: 232 E. MAIN ST. Aspen, CO 81611 Owner/Agent: Brad Hribar Centaur Construction 1200 W Lake St Suite 200 Chicago, IL 60607 312-714-8519 bhribar@centaurco.com Designer/Contractor: Steve Coughlin modif. architecture 1229 N. North Branch Street Suite 206 Chicago, IL 60642 708-261-2611 steve.coughlin@modifarchitecture.c om Project Information Energy Code: 232 MAIN ST. 1%Skylight / Roof Area Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Building Area Floor Area 1-Ground Floor (Retail) : Nonresidential 4445 2-Second Floor (Office) : Nonresidential 1600 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof 1 wood shigle roof (type 1): Attic Roof with Wood Joists, [Bldg. Use 2 - Second Floor] 2393 19.0 23.6 0.023 0.021 Roof 2 gable roof (type 2): Insulation Entirely Above Deck, [Bldg. Use 1 - Ground Floor] 2142 ---23.6 0.041 0.028 Skylight 1: Metal Frame with Thermal Break:Glass, No Curb, Perf. Type: Energy code default, Double Pane, Clear , SHGC 0.70, VT 0.60, [Bldg. Use 1 - Ground Floor] 62 ------1.100 0.500 Roof 2 second level plaza deck floor (type 3): Insulation Entirely Above Deck, [Bldg. Use 1 - Ground Floor] 1200 ---8.6 0.107 0.028 Floor 1 (type 2A): Slab-On-Grade:Unheated, [Bldg. Use 1 - Ground Floor] (d) 275 ------0.730 0.520 NORTH Exterior North Wall (type D): Concrete Block:8", Partially Grouted, Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] 603 0.0 15.0 0.055 0.071 Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - Ground Floor]21 ------0.660 0.370 Exterior NorthWall (type C6): Steel-Framed, 16" o.c., [Bldg. Use 2 - Second Floor] 167 19.0 15.0 0.041 0.064 Exterior North Wall (type D2): Concrete Block:8", Partially Grouted,477 0.0 15.0 0.055 0.071 Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 131 ofPage 01/13/2020 Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] Door 9: Insulated Metal, Non-Swinging, [Bldg. Use 1 - Ground Floor]90 ------0.140 0.179 EAST Exterior East Wall (type C8): Steel-Framed, 16" o.c., [Bldg. Use 1 - Ground Floor] 807 25.0 20.0 0.032 0.064 Window 4 around door C-1: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 41 ------0.290 0.290 Window 5: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 97 ------0.290 0.290 Window 6: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 97 ------0.290 0.290 Window 7: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 108 ------0.290 0.290 Window 10: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.27, PF 0.33, VT 0.56, [Bldg. Use 1 - Ground Floor] (c) 22 ------0.340 0.290 Door 4 (type C-1): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID PORTELLA, SHGC 0.22, PF 0.14, VT 0.45, [Bldg. Use 1 - Ground Floor] (c) 66 ------0.350 0.770 Exterior East Wall (type B1): Steel-Framed, 16" o.c., [Bldg. Use 1 - Ground Floor] 476 0.0 15.0 0.056 0.064 Window 10: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 54 ------0.290 0.290 Window 9 around door: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 45 ------0.290 0.290 Door 3 (type C): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID PORTELLA, SHGC 0.22, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 63 ------0.350 0.770 Exterior East Wall (type D): Concrete Block:8", Partially Grouted, Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] 35 0.0 15.0 0.055 0.071 SOUTH Exterior South Wall (Curtain Wall): Steel-Framed, 16" o.c., [Bldg. Use 1 - Ground Floor] 1224 19.0 0.0 0.109 0.064 Window 1: Other Window:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.27, PF 0.33, VT 0.56, [Bldg. Use 1 - Ground Floor] (c) 506 ------0.340 0.290 Door 2: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID PORTELLA, SHGC 0.22, PF 0.33, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 60 ------0.350 0.770 Door 2 -1: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID Nanawall HSW60, SHGC 0.27, PF 0.33, VT 0.33, [Bldg. Use 1 - Ground Floor] (c) 84 ------0.340 0.770 Door 2 -2: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID Nanawall HSW60, SHGC 0.27, PF 0.33, VT 0.33, [Bldg. Use 1 - Ground Floor] (c) 290 ------0.340 0.770 WEST Exterior West Wall (type A4): Concrete Block:8", Partially Grouted, Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] 1225 0.0 15.0 0.055 0.071 Exterior West Wall (type C6): Steel-Framed, 16" o.c., [Bldg. Use 2 - Second Floor] 476 19.0 15.0 0.041 0.064 Window 13: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEEER, SHGC 0.27, VT 0.56, [Bldg. Use 2 - Second 6 ------0.340 0.290 Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 132 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Floor] (c) Window 12 around door D: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, VT 0.34, [Bldg. Use 2 - Second Floor] (c) 48 ------0.290 0.290 Door 5 (type D): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID PORTELLA, SHGC 0.22, VT 0.45, [Bldg. Use 2 - Second Floor] (c) 42 ------0.350 0.770 Exterior West Wall (type D): Concrete Block:8", Partially Grouted, Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] 74 0.0 15.0 0.055 0.071 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)'Other' components require supporting documentation for proposed U-factors. (c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (d)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 4% better than code Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 133 ofPage STEVE COUGHLIN - PRINCIPAL 1-13-2020 COMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit No.0132.2018.ACBK Permit Date:2019 Construction Site: 232 East Main Street Aspen, CO 81611 Owner/Agent: Brad Hribar Centaur Construction 1200 W Lake St Ste 200 Chicago, IL 60607 3127148519 bhribar@centaurco.com Designer/Contractor: Zachary Gains AEC 9707488520 zach@aec-vail.com Project Information Energy Code: 232 East Main Street Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Retail:Sales Area 4302 1.43 6152 6152Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures 1-Retail:Sales Area LED 1: Fixture Type F: Other:1 20 42 840 840Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES: Design 86% better than code Project Title: Data filename: 232 East Main Street P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Electrical COMcheck.cck 12/18/19Report date: 71 ofPage Zachary Gains 12/18/19 12/20/2019 COMcheck Software Version 4.1.1.0 Exterior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit No.0132.2018.ACBK Permit Date:2019 Construction Site: 232 East Main Street Aspen, CO 81611 Owner/Agent: Brad Hribar Centaur Construction 1200 W Lake St Ste 200 Chicago, IL 60607 3127148519 bhribar@centaurco.com Designer/Contractor: Zachary Gains AEC 9707488520 zach@aec-vail.com Project Information Energy Code: 232 East Main Street 4 (High activity metropolitan commercial district)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Main entry 90 ft of door 30 Yes 2700 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 2700 2700 1300 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 1300 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Main entry (90 ft of door width): Tradable Wattage LED 1: FIXTURE A: Other:1 11 17 187 LED 2: FIXTURE B: Other:1 2 10 21 LED 3: FIXTURE H: Other:1 1 25 25 233Total Tradable Proposed Watts = Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES: Design 94% better than code Project Title: Data filename: 232 East Main Street P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Electrical COMcheck.cck 12/18/19Report date: 72 ofPage Zachary Gains 12/18/19 12/20/2019 COMcheck Software Version 4.1.1.0 Mechanical Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit No..0132.2018.ACBK Permit Date:2018 Location:Aspen, Colorado Climate Zone:7 Construction Site: 232 E Main St Aspen, CO 81611 Owner/Agent: Brad Hribar Centaur Construction 1200 W Lake St Suite 200 Chicago, IL 60607 3127148519 bhribar@centaurco.com Designer/Contractor: Bryan Urban AEC 40801 US Hwy 6 Ste 214 Avon, CO 81620 970-748-8520 burban@aec-vail.com Project Information Energy Code: 232 E Main Core and Shell Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Mechanical Systems List Quantity System Type & Description Heating: 1 each - Central Furnace, Gas, Capacity = 150 kBtu/h Proposed Efficiency = 80.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 73 kBtu/h, Evaporatively Cooled Condenser, Air Economizer Proposed Efficiency = 12.80 EER, Required Efficiency: 11.90 EER + 12.1 IEER Fan System: RTU-1 FAN -- Compliance (Brake HP method) : Passes Fans: RTU 1 FAN Supply, Multi-Zone VAV, 3000 CFM, 5.0 motor nameplate hp, 2.4 design brake hp (2.4 max. BHP), 80.0 fan efficiency grade 1 RTU-1 (Multiple-Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 150 kBtu/h Proposed Efficiency = 80.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 87 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 13.50 EER, Required Efficiency: 11.00 EER + 12.6 IEER Fan System: RTU-1 FAN -- Compliance (Brake HP method) : Passes Fans: RTU 1 FAN Supply, Multi-Zone VAV, 3000 CFM, 5.0 motor nameplate hp, 2.4 design brake hp (2.4 max. BHP), 80.0 fan efficiency grade 1 RTU-2 (Multiple-Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 72 kBtu/h Proposed Efficiency = 82.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 30 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 15.50 SEER, Required Efficiency: 14.00 SEER Fan System: RTU-3 FAN -- Compliance (Brake HP method) : Passes Fans: RTU 3 FAN Supply, Multi-Zone VAV, 1380 CFM, 1.5 motor nameplate hp, 0.9 design brake hp (0.9 max. BHP), 80.0 fan efficiency grade 1 RTU-3 (Multiple-Zone): Project Title: Data filename: 232 E Main Core and Shell P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Mechanical COMcheck.cck 12/18/19Report date: 171 ofPage12/20/2019 Quantity System Type & Description Heating: 1 each - Central Furnace, Gas, Capacity = 72 kBtu/h Proposed Efficiency = 82.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 41 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 16.40 SEER, Required Efficiency: 14.00 SEER Fan System: RTU-4 FAN -- Compliance (Brake HP method) : Passes Fans: RTU 4 FAN Supply, Multi-Zone VAV, 2000 CFM, 3.0 motor nameplate hp, 1.8 design brake hp (1.8 max. BHP), 80.0 fan efficiency grade 1 RTU-4 (Multiple-Zone): Heating: 1 each - Unit Heater (UH-1), Electric, Capacity = 3 kBtu/h No minimum efficiency requirement applies Fan System: None 3 UH-1 (Single Zone): Heating: 1 each - Unit Heater (UH-2), Electric, Capacity = 5 kBtu/h No minimum efficiency requirement applies Fan System: None 1 UH-2 (Single Zone): Heating: Hot Water Boiler, Capacity 1250 kBtu/h, Gas Proposed Efficiency: 95.00 % Et, Required Efficiency: 80.00 % Et 1 Boiler-1: Electric Storage Water Heater, Capacity: 7 gallons Proposed Efficiency: 2.00 SL, %/h (if > 12 kW), Required Efficiency: 4.16 SL, %/h (if > 12 kW) 1 WH-1: Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Data filename: 232 E Main Core and Shell P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Mechanical COMcheck.cck 12/18/19Report date: 172 ofPage Bryan Urban 12/18/19 12/20/2019 01/ 1 3 / 2 0 2 0 nic k t