HomeMy WebLinkAboutFile Documents.232 E Main St.0078-2020-BCHO (96)The City of Aspen
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
CORE AND SHELL PERMIT.
TENANT FINISHES ON
SEPARATE PERMITS
FIRE
SPRINKLERS
REQUIRED
COMcheck Software Version 4.1.5.1
Envelope Compliance Certificate
Project Title:
2015 IECC
Project Type:New Construction
Permit Date:1/2018
Vertical Glazing / Wall Area:29%
Location:Aspen, Colorado
Climate Zone:7
Construction Site:
232 E. MAIN ST.
Aspen, CO 81611
Owner/Agent:
232 East Main Street LLC
2001 N. Halsted St. Suite 304
Chicago, IL 60614
312-850-1680
Designer/Contractor:
Steve Coughlin
modif. architecture
1229 N North Branch St. Suite 206
Chicago, IL 60642
708-261-2611
steve.coughlin@modifarchitecture.c
om
Project Information
Energy Code:
232 MAIN ST.
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations.
Additional Efficiency Package(s)
Building Area Floor Area
1-Ground Floor (Retail) : Nonresidential 4445
2-Second Floor (Office) : Nonresidential 1600
Envelope Assemblies
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Roof 1 wood shingle roof (type 1): Other Insulation Above Deck, [Bldg.
Use 2 - Second Floor] (b)
1492 ------0.038 0.028
Roof 2 gable roof (type 2): Other Insulation Above Deck, [Bldg. Use 1 -
Ground Floor] (b)
1347 ------0.058 0.028
Roof 3 second level plaza deck floor (type 3): Other Insulation Above
Deck, [Bldg. Use 1 - Ground Floor] (b)
1200 ------0.061 0.028
Floor (type 2A): Slab-On-Grade:Unheated, [Bldg. Use 1 - Ground
Floor] (d)
275 ------0.730 0.520
NORTH
Exterior North Wall (type D): Other Exterior Wall, Heat capacity 1.0,
[Bldg. Use 1 - Ground Floor] (b)
603 ------0.049 0.051
Door (type U): Other Door, Swinging, [Bldg. Use 1 - Ground Floor]21 ------0.660 0.370
Door (type T): Insulated Metal, Swinging, [Bldg. Use 1 - Ground Floor]21 ------0.660 0.370
Exterior North Wall (type D): Other Exterior Wall, Heat capacity 1.0,
[Bldg. Use 2 - Second Floor] (b)
167 ------0.049 0.051
Exterior North Wall (type D): Other Exterior Wall, Heat capacity 1.0,
[Bldg. Use 1 - Ground Floor] (b)
35 ------0.049 0.051
Exterior North Wall (type D2): Other Exterior Wall, Heat capacity 1.0,
[Bldg. Use 1 - Ground Floor] (b)
477 ------0.069 0.051
Door (type R): Insulated Metal, Non-Swinging, [Bldg. Use 1 - Ground 90 ------0.140 0.179
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 03-11-21_4.1.5.1.cck
03/18/21Report date:
101 ofPage
03/18/2021
03/18/2021
nickt
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Floor]
Exterior North Wall (type A5): Other Steel Framed Wall, [Bldg. Use 1 -
Ground Floor] (b)
26 ------0.078 0.064
EAST
Exterior East Wall (type C6 + G2): Other Steel Framed Wall, [Bldg. Use
1 - Ground Floor] (b)
334 ------0.038 0.064
Window 5: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 - Ground
Floor] (c)
102 ------0.350 0.290
Window 6: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 - Ground
Floor] (c)
102 ------0.350 0.290
Window 11: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID KAWNEER, SHGC 0.22, [Bldg. Use 1 - Ground Floor] (c)
14 ------0.480 0.290
Exterior East Wall (type C6): Other Exterior Wall, Heat capacity 1.0,
[Bldg. Use 1 - Ground Floor] (b)
363 ------0.038 0.051
Window 4 around door C-1: Metal Frame with Thermal Break:Fixed,
Perf. Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1
- Ground Floor] (c)
51 ------0.350 0.290
Window 7: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 - Ground
Floor] (c)
113 ------0.350 0.290
Door 4 (type C-1): Glass (> 50% glazing):Metal Frame, Entrance Door,
Perf. Specs.: Product ID KAWNEER, SHGC 0.22, PF 0.14, [Bldg. Use 1
- Ground Floor] (c)
61 ------0.290 0.770
Exterior East Wall (type B-1): Other Steel Framed Wall, [Bldg. Use 1 -
Ground Floor] (b)
476 ------0.032 0.064
Window 10: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 - Ground
Floor] (c)
37 ------0.350 0.290
Window 9 around door C: Metal Frame with Thermal Break:Fixed, Perf.
Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 -
Ground Floor] (c)
37 ------0.350 0.290
Door (type C): Glass (> 50% glazing):Metal Frame, Entrance Door,
Perf. Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1
- Ground Floor] (c)
63 ------0.350 0.770
Exterior East Exposed Foundation: Solid Concrete:12" Thickness,
Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor]
39 0.0 0.0 0.346 0.071
SOUTH
Exterior South Wall (Curtain Wall): Steel-Framed, 16" o.c., [Bldg. Use 1
- Ground Floor]
1224 19.0 0.0 0.109 0.064
Window 1: Other Window:Fixed, Perf. Specs.: Product ID KAWNEER,
SHGC 0.27, PF 0.33, [Bldg. Use 1 - Ground Floor] (c)
492 ------0.420 0.290
Window around door type L: Metal Frame with Thermal Break:Fixed,
Perf. Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.33, [Bldg. Use 1
- Ground Floor] (c)
34 ------0.350 0.290
Door (type L): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf.
Specs.: Product ID KAWNEER, SHGC 0.24, PF 0.33, [Bldg. Use 1 -
Ground Floor] (c)
56 ------0.290 0.770
Door (type N): Glass (> 50% glazing):Metal Frame, Non-Entrance Door,
Perf. Specs.: Product ID SOLAR INNOVATIONS, SHGC 0.19, PF 0.33,
[Bldg. Use 1 - Ground Floor] (c)
92 ------0.280 0.370
Door (type J): Glass (> 50% glazing):Metal Frame, Non-Entrance Door,
Perf. Specs.: Product ID SOLAR INNOVATIONS, SHGC 0.19, PF 0.66,
[Bldg. Use 1 - Ground Floor] (c)
81 ------0.280 0.370
Door (type O): Glass (> 50% glazing):Metal Frame, Entrance Door,
Perf. Specs.: Product ID SOLAR INNOVATIONS, SHGC 0.19, PF 0.33,
[Bldg. Use 1 - Ground Floor] (c)
88 ------0.280 0.770
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 03-11-21_4.1.5.1.cck
03/18/21Report date:
102 ofPage
03/18/2021
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Door (type E): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf.
Specs.: Product ID SOLAR INNOVATIONS, SHGC 0.19, PF 0.64,
[Bldg. Use 1 - Ground Floor] (c)
85 ------0.280 0.770
WEST
Exterior West Wall (type A4): Other Steel Framed Wall, [Bldg. Use 1 -
Ground Floor] (b)
1224 ------0.018 0.064
Exterior West Wall (type C7 + C4): Other Steel Framed Wall, [Bldg. Use
1 - Ground Floor] (b)
476 ------0.030 0.064
Window 12 around door D: Metal Frame with Thermal Break:Fixed,
Perf. Specs.: Product ID KAWNEER, SHGC 0.25, [Bldg. Use 1 -
Ground Floor] (c)
58 ------0.350 0.290
Door (type D): Glass (> 50% glazing):Metal Frame, Entrance Door,
Perf. Specs.: Product ID KAWNEER, SHGC 0.22, [Bldg. Use 1 -
Ground Floor] (c)
42 ------0.290 0.770
Exterior West Wall (type D3): Other Exterior Wall, Heat capacity 1.0,
[Bldg. Use 1 - Ground Floor] (b)
74 ------0.038 0.051
(a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b)'Other' components require supporting documentation for proposed U-factors.
(c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(d)Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Name - Title Signature Date
Envelope PASSES: Design 0.1% better than code
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 03-11-21_4.1.5.1.cck
03/18/21Report date:
103 ofPage
STEVE COUGHLIN - PRINCIPAL 03/18/2021
03/18/2021
03/18/2021
03/18/2021
nickt
SEE NOTES #1 PLANS
05/12/2021
nickt
MANDATORY TESTING
REQUIRED
This construction project is required to
comply with the 2015 International
Energy Conservation Code.
Commercial projects will require a
blower door test performed in the
manner complying with section C402.5
of the 2015 IECC.
Maximum 0.40 cfm/sqft at 75 Pa.
SPECIAL INSPECTION REQUIRED:
-Structural steel welding: Field & Shop
-High strength bolting
-Intumescent paint
Special inspection is required per 2015 IBC
section 1704. Inspector to verify that copy of
agreement for inspection program to be on
the job site prior to performing any
inspections. A copy of all Special Inspector
field reports to be on the job site for
inspectors' review if requested. Failure to
comply may result in denial of inspection.
External Energy Use Approved
RREMP CREMP
PERMIT #:_______________DATE:________
SNOWMELT:_____________________________
POOL: _____________________________
SPA: _____________________________
OFFSET:________________________________
REMP SHEET: __________________________
REVIEWED BY: _________________________
SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S.
All snowmelt systems shall meet the following:
-Any portions in the Right of Way must be on a separate zone. A ROW
permit and Permanent Encroachment License are required.
-R10 insulation shall be installed under the area to be snow melted or R5
insulation shall be installed under and at the slab edges. (Ordinance 11
Series 2011)
-Automatic controls installed for system shut off when pavement
temperature is above 50°F and no precipitation is falling. (2009 IECC
Sec. 403.8 & 503.2.4.5)
-Automatic or manual controls installed for system shut off when outdoor
temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5)
-Inspection by testing hydrostatically at 1½ times max system design
pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec.
1208.1)
MINIMUM BOILER AFUE: _________________
0
COMcheck Software Version 4.1.5.1
Mechanical Compliance Certificate
Project Title:
2015 IECC
Project Type:New Construction
Permit No..0132.2018.ACBK
Permit Date:2018
Location:Aspen, Colorado
Climate Zone:7
Construction Site:
232 E Main St
Aspen, CO 81611
Owner/Agent:
Brad Hribar
Centaur Construction
1200 W Lake St Suite 200
Chicago, IL 60607
3127148519
bhribar@centaurco.com
Designer/Contractor:
Bryan Urban
AEC
40801 US Hwy 6
Ste 214
Avon, CO 81620
970-748-8520
burban@aec-vail.com
Project Information
Energy Code:
232 E Main Core and Shell
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations.
Additional Efficiency Package(s)
Mechanical Systems List
Quantity System Type & Description
Heating: 1 each - Central Furnace, Gas, Capacity = 150 kBtu/h
Proposed Efficiency = 80.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE
Cooling: 1 each - Single Package DX Unit, Capacity = 73 kBtu/h, Evaporatively Cooled Condenser, Air Economizer
Proposed Efficiency = 12.80 EER, Required Efficiency: 11.90 EER + 12.1 IEER
Fan System: RTU-1 FAN -- Compliance (Brake HP method) : Passes
Fans:
RTU 1 FAN Supply, Multi-Zone VAV, 3000 CFM, 5.0 motor nameplate hp, 2.4 design brake hp (2.4 max. BHP), 80.0 fan efficiency
grade
1 RTU-1 (Multiple-Zone):
Heating: 1 each - Central Furnace, Gas, Capacity = 150 kBtu/h
Proposed Efficiency = 80.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE
Cooling: 1 each - Single Package DX Unit, Capacity = 87 kBtu/h, Air-Cooled Condenser, Air Economizer
Proposed Efficiency = 13.50 EER, Required Efficiency: 11.00 EER + 12.6 IEER
Fan System: RTU-1 FAN -- Compliance (Brake HP method) : Passes
Fans:
RTU 1 FAN Supply, Multi-Zone VAV, 3000 CFM, 5.0 motor nameplate hp, 2.4 design brake hp (2.4 max. BHP), 80.0 fan efficiency
grade
1 RTU-2 (Multiple-Zone):
Heating: 1 each - Central Furnace, Gas, Capacity = 72 kBtu/h
Proposed Efficiency = 82.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE
Cooling: 1 each - Single Package DX Unit, Capacity = 30 kBtu/h, Air-Cooled Condenser, Air Economizer
Proposed Efficiency = 15.50 SEER, Required Efficiency: 14.00 SEER
Fan System: RTU-3 FAN -- Compliance (Brake HP method) : Passes
Fans:
RTU 3 FAN Supply, Multi-Zone VAV, 1380 CFM, 1.5 motor nameplate hp, 0.9 design brake hp (0.9 max. BHP), 80.0 fan efficiency
grade
1 RTU-3 (Multiple-Zone):
Project Title:
Data filename:
232 E Main Core and Shell
P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Mechanical
COMcheck 01-20-2021.cck
03/08/21Report date:
151 ofPage
4/14/2021
Quantity System Type & Description
Heating: 1 each - Central Furnace, Gas, Capacity = 72 kBtu/h
Proposed Efficiency = 82.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE
Cooling: 1 each - Single Package DX Unit, Capacity = 41 kBtu/h, Air-Cooled Condenser, Air Economizer
Proposed Efficiency = 16.40 SEER, Required Efficiency: 14.00 SEER
Fan System: RTU-4 FAN -- Compliance (Brake HP method) : Passes
Fans:
RTU 4 FAN Supply, Multi-Zone VAV, 2000 CFM, 3.0 motor nameplate hp, 1.8 design brake hp (1.8 max. BHP), 80.0 fan efficiency
grade
1 RTU-4 (Multiple-Zone):
Heating: 1 each - Unit Heater (UH-1), Electric, Capacity = 3 kBtu/h
No minimum efficiency requirement applies
Fan System: None
5 UH-1 (Single Zone):
Heating: 1 each - Unit Heater (UH-2), Electric, Capacity = 5 kBtu/h
No minimum efficiency requirement applies
Fan System: None
4 UH-2 (Single Zone):
Electric Storage Water Heater, Capacity: 7 gallons
Proposed Efficiency: 2.00 SL, %/h (if > 12 kW), Required Efficiency: 4.16 SL, %/h (if > 12 kW)
1 WH-1:
Mechanical Compliance Statement
Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Name - Title Signature Date
Project Title:
Data filename:
232 E Main Core and Shell
P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Mechanical
COMcheck 01-20-2021.cck
03/08/21Report date:
152 ofPage
Bryan Urban 03-08-2021
4/14/2021
COMcheck Software Version 4.1.1.0
Exterior Lighting Compliance Certificate
Project Title:
2015 IECC
Project Type:New Construction
Permit No.0132.2018.ACBK
Permit Date:2019
Construction Site:
232 East Main Street
Aspen, CO 81611
Owner/Agent:
Brad Hribar
Centaur Construction
1200 W Lake St Ste 200
Chicago, IL 60607
3127148519
bhribar@centaurco.com
Designer/Contractor:
Zachary Gains
AEC
9707488520
zach@aec-vail.com
Project Information
Energy Code:
232 East Main Street
4 (High activity metropolitan commercial district)Exterior Lighting Zone
Allowed Exterior Lighting Power
A
Area/Surface Category
B
Quantity
C
Allowed
Watts / Unit
D
Tradable
Wattage
E
Allowed Watts
(B X C)
Main entry 90 ft of door 30 Yes 2700
Total Tradable Watts (a) =
Total Allowed Watts =
Total Allowed Supplemental Watts (b) =
2700
2700
1300
(a)Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b)A supplemental allowance equal to 1300 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
Main entry (90 ft of door width): Tradable Wattage
LED 1: FIXTURE A: Other:1 11 17 187
LED 2: FIXTURE B: Other:1 4 10 42
LED 3: FIXTURE H: Other:1 1 25 25
254Total Tradable Proposed Watts =
Exterior Lighting Compliance Statement
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Name - Title Signature Date
Exterior Lighting PASSES: Design 94% better than code
Project Title:
Data filename:
232 East Main Street
P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Electrical
COMcheck.cck
03/08/21Report date:
51 ofPage
Zachary Gains 03/08/2021
4/14/2021
04/23/2021
nickt
See master permit for interior lighting
comcheck
05/12/2021
nickt
4/14/2021
04/23/2021
nickt
4/14/2021 4/14/2021
04/23/2021
nickt
4/14/2021
4/14/2021
05/12/2021
nickt