Loading...
HomeMy WebLinkAboutFile Documents.232 E Main St.0078-2020-BCHO (96)The City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK CORE AND SHELL PERMIT. TENANT FINISHES ON SEPARATE PERMITS FIRE SPRINKLERS REQUIRED COMcheck Software Version 4.1.5.1 Envelope Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit Date:1/2018 Vertical Glazing / Wall Area:29% Location:Aspen, Colorado Climate Zone:7 Construction Site: 232 E. MAIN ST. Aspen, CO 81611 Owner/Agent: 232 East Main Street LLC 2001 N. Halsted St. Suite 304 Chicago, IL 60614 312-850-1680 Designer/Contractor: Steve Coughlin modif. architecture 1229 N North Branch St. Suite 206 Chicago, IL 60642 708-261-2611 steve.coughlin@modifarchitecture.c om Project Information Energy Code: 232 MAIN ST. Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Building Area Floor Area 1-Ground Floor (Retail) : Nonresidential 4445 2-Second Floor (Office) : Nonresidential 1600 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof 1 wood shingle roof (type 1): Other Insulation Above Deck, [Bldg. Use 2 - Second Floor] (b) 1492 ------0.038 0.028 Roof 2 gable roof (type 2): Other Insulation Above Deck, [Bldg. Use 1 - Ground Floor] (b) 1347 ------0.058 0.028 Roof 3 second level plaza deck floor (type 3): Other Insulation Above Deck, [Bldg. Use 1 - Ground Floor] (b) 1200 ------0.061 0.028 Floor (type 2A): Slab-On-Grade:Unheated, [Bldg. Use 1 - Ground Floor] (d) 275 ------0.730 0.520 NORTH Exterior North Wall (type D): Other Exterior Wall, Heat capacity 1.0, [Bldg. Use 1 - Ground Floor] (b) 603 ------0.049 0.051 Door (type U): Other Door, Swinging, [Bldg. Use 1 - Ground Floor]21 ------0.660 0.370 Door (type T): Insulated Metal, Swinging, [Bldg. Use 1 - Ground Floor]21 ------0.660 0.370 Exterior North Wall (type D): Other Exterior Wall, Heat capacity 1.0, [Bldg. Use 2 - Second Floor] (b) 167 ------0.049 0.051 Exterior North Wall (type D): Other Exterior Wall, Heat capacity 1.0, [Bldg. Use 1 - Ground Floor] (b) 35 ------0.049 0.051 Exterior North Wall (type D2): Other Exterior Wall, Heat capacity 1.0, [Bldg. Use 1 - Ground Floor] (b) 477 ------0.069 0.051 Door (type R): Insulated Metal, Non-Swinging, [Bldg. Use 1 - Ground 90 ------0.140 0.179 Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 03-11-21_4.1.5.1.cck 03/18/21Report date: 101 ofPage 03/18/2021 03/18/2021 nickt Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Floor] Exterior North Wall (type A5): Other Steel Framed Wall, [Bldg. Use 1 - Ground Floor] (b) 26 ------0.078 0.064 EAST Exterior East Wall (type C6 + G2): Other Steel Framed Wall, [Bldg. Use 1 - Ground Floor] (b) 334 ------0.038 0.064 Window 5: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 - Ground Floor] (c) 102 ------0.350 0.290 Window 6: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 - Ground Floor] (c) 102 ------0.350 0.290 Window 11: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.22, [Bldg. Use 1 - Ground Floor] (c) 14 ------0.480 0.290 Exterior East Wall (type C6): Other Exterior Wall, Heat capacity 1.0, [Bldg. Use 1 - Ground Floor] (b) 363 ------0.038 0.051 Window 4 around door C-1: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 - Ground Floor] (c) 51 ------0.350 0.290 Window 7: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 - Ground Floor] (c) 113 ------0.350 0.290 Door 4 (type C-1): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID KAWNEER, SHGC 0.22, PF 0.14, [Bldg. Use 1 - Ground Floor] (c) 61 ------0.290 0.770 Exterior East Wall (type B-1): Other Steel Framed Wall, [Bldg. Use 1 - Ground Floor] (b) 476 ------0.032 0.064 Window 10: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 - Ground Floor] (c) 37 ------0.350 0.290 Window 9 around door C: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 - Ground Floor] (c) 37 ------0.350 0.290 Door (type C): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.14, [Bldg. Use 1 - Ground Floor] (c) 63 ------0.350 0.770 Exterior East Exposed Foundation: Solid Concrete:12" Thickness, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] 39 0.0 0.0 0.346 0.071 SOUTH Exterior South Wall (Curtain Wall): Steel-Framed, 16" o.c., [Bldg. Use 1 - Ground Floor] 1224 19.0 0.0 0.109 0.064 Window 1: Other Window:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.27, PF 0.33, [Bldg. Use 1 - Ground Floor] (c) 492 ------0.420 0.290 Window around door type L: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.25, PF 0.33, [Bldg. Use 1 - Ground Floor] (c) 34 ------0.350 0.290 Door (type L): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID KAWNEER, SHGC 0.24, PF 0.33, [Bldg. Use 1 - Ground Floor] (c) 56 ------0.290 0.770 Door (type N): Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID SOLAR INNOVATIONS, SHGC 0.19, PF 0.33, [Bldg. Use 1 - Ground Floor] (c) 92 ------0.280 0.370 Door (type J): Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID SOLAR INNOVATIONS, SHGC 0.19, PF 0.66, [Bldg. Use 1 - Ground Floor] (c) 81 ------0.280 0.370 Door (type O): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID SOLAR INNOVATIONS, SHGC 0.19, PF 0.33, [Bldg. Use 1 - Ground Floor] (c) 88 ------0.280 0.770 Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 03-11-21_4.1.5.1.cck 03/18/21Report date: 102 ofPage 03/18/2021 Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Door (type E): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID SOLAR INNOVATIONS, SHGC 0.19, PF 0.64, [Bldg. Use 1 - Ground Floor] (c) 85 ------0.280 0.770 WEST Exterior West Wall (type A4): Other Steel Framed Wall, [Bldg. Use 1 - Ground Floor] (b) 1224 ------0.018 0.064 Exterior West Wall (type C7 + C4): Other Steel Framed Wall, [Bldg. Use 1 - Ground Floor] (b) 476 ------0.030 0.064 Window 12 around door D: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.25, [Bldg. Use 1 - Ground Floor] (c) 58 ------0.350 0.290 Door (type D): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID KAWNEER, SHGC 0.22, [Bldg. Use 1 - Ground Floor] (c) 42 ------0.290 0.770 Exterior West Wall (type D3): Other Exterior Wall, Heat capacity 1.0, [Bldg. Use 1 - Ground Floor] (b) 74 ------0.038 0.051 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)'Other' components require supporting documentation for proposed U-factors. (c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (d)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 0.1% better than code Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 03-11-21_4.1.5.1.cck 03/18/21Report date: 103 ofPage STEVE COUGHLIN - PRINCIPAL 03/18/2021 03/18/2021 03/18/2021 03/18/2021 nickt SEE NOTES #1 PLANS 05/12/2021 nickt MANDATORY TESTING REQUIRED This construction project is required to comply with the 2015 International Energy Conservation Code. Commercial projects will require a blower door test performed in the manner complying with section C402.5 of the 2015 IECC. Maximum 0.40 cfm/sqft at 75 Pa. SPECIAL INSPECTION REQUIRED: -Structural steel welding: Field & Shop -High strength bolting -Intumescent paint Special inspection is required per 2015 IBC section 1704. Inspector to verify that copy of agreement for inspection program to be on the job site prior to performing any inspections. A copy of all Special Inspector field reports to be on the job site for inspectors' review if requested. Failure to comply may result in denial of inspection. External Energy Use Approved RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:________________________________ REMP SHEET: __________________________ REVIEWED BY: _________________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: _________________ 0 COMcheck Software Version 4.1.5.1 Mechanical Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit No..0132.2018.ACBK Permit Date:2018 Location:Aspen, Colorado Climate Zone:7 Construction Site: 232 E Main St Aspen, CO 81611 Owner/Agent: Brad Hribar Centaur Construction 1200 W Lake St Suite 200 Chicago, IL 60607 3127148519 bhribar@centaurco.com Designer/Contractor: Bryan Urban AEC 40801 US Hwy 6 Ste 214 Avon, CO 81620 970-748-8520 burban@aec-vail.com Project Information Energy Code: 232 E Main Core and Shell Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Mechanical Systems List Quantity System Type & Description Heating: 1 each - Central Furnace, Gas, Capacity = 150 kBtu/h Proposed Efficiency = 80.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 73 kBtu/h, Evaporatively Cooled Condenser, Air Economizer Proposed Efficiency = 12.80 EER, Required Efficiency: 11.90 EER + 12.1 IEER Fan System: RTU-1 FAN -- Compliance (Brake HP method) : Passes Fans: RTU 1 FAN Supply, Multi-Zone VAV, 3000 CFM, 5.0 motor nameplate hp, 2.4 design brake hp (2.4 max. BHP), 80.0 fan efficiency grade 1 RTU-1 (Multiple-Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 150 kBtu/h Proposed Efficiency = 80.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 87 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 13.50 EER, Required Efficiency: 11.00 EER + 12.6 IEER Fan System: RTU-1 FAN -- Compliance (Brake HP method) : Passes Fans: RTU 1 FAN Supply, Multi-Zone VAV, 3000 CFM, 5.0 motor nameplate hp, 2.4 design brake hp (2.4 max. BHP), 80.0 fan efficiency grade 1 RTU-2 (Multiple-Zone): Heating: 1 each - Central Furnace, Gas, Capacity = 72 kBtu/h Proposed Efficiency = 82.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 30 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 15.50 SEER, Required Efficiency: 14.00 SEER Fan System: RTU-3 FAN -- Compliance (Brake HP method) : Passes Fans: RTU 3 FAN Supply, Multi-Zone VAV, 1380 CFM, 1.5 motor nameplate hp, 0.9 design brake hp (0.9 max. BHP), 80.0 fan efficiency grade 1 RTU-3 (Multiple-Zone): Project Title: Data filename: 232 E Main Core and Shell P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Mechanical COMcheck 01-20-2021.cck 03/08/21Report date: 151 ofPage 4/14/2021 Quantity System Type & Description Heating: 1 each - Central Furnace, Gas, Capacity = 72 kBtu/h Proposed Efficiency = 82.00% Et, Required Efficiency: 80.00 % Et or 78% AFUE Cooling: 1 each - Single Package DX Unit, Capacity = 41 kBtu/h, Air-Cooled Condenser, Air Economizer Proposed Efficiency = 16.40 SEER, Required Efficiency: 14.00 SEER Fan System: RTU-4 FAN -- Compliance (Brake HP method) : Passes Fans: RTU 4 FAN Supply, Multi-Zone VAV, 2000 CFM, 3.0 motor nameplate hp, 1.8 design brake hp (1.8 max. BHP), 80.0 fan efficiency grade 1 RTU-4 (Multiple-Zone): Heating: 1 each - Unit Heater (UH-1), Electric, Capacity = 3 kBtu/h No minimum efficiency requirement applies Fan System: None 5 UH-1 (Single Zone): Heating: 1 each - Unit Heater (UH-2), Electric, Capacity = 5 kBtu/h No minimum efficiency requirement applies Fan System: None 4 UH-2 (Single Zone): Electric Storage Water Heater, Capacity: 7 gallons Proposed Efficiency: 2.00 SL, %/h (if > 12 kW), Required Efficiency: 4.16 SL, %/h (if > 12 kW) 1 WH-1: Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Data filename: 232 E Main Core and Shell P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Mechanical COMcheck 01-20-2021.cck 03/08/21Report date: 152 ofPage Bryan Urban 03-08-2021 4/14/2021 COMcheck Software Version 4.1.1.0 Exterior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit No.0132.2018.ACBK Permit Date:2019 Construction Site: 232 East Main Street Aspen, CO 81611 Owner/Agent: Brad Hribar Centaur Construction 1200 W Lake St Ste 200 Chicago, IL 60607 3127148519 bhribar@centaurco.com Designer/Contractor: Zachary Gains AEC 9707488520 zach@aec-vail.com Project Information Energy Code: 232 East Main Street 4 (High activity metropolitan commercial district)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Main entry 90 ft of door 30 Yes 2700 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 2700 2700 1300 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 1300 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Main entry (90 ft of door width): Tradable Wattage LED 1: FIXTURE A: Other:1 11 17 187 LED 2: FIXTURE B: Other:1 4 10 42 LED 3: FIXTURE H: Other:1 1 25 25 254Total Tradable Proposed Watts = Exterior Lighting Compliance Statement Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Exterior Lighting PASSES: Design 94% better than code Project Title: Data filename: 232 East Main Street P:\Current Projects\18029.00 - 232 East Main Street\Calculations\COMcheck\Electrical COMcheck.cck 03/08/21Report date: 51 ofPage Zachary Gains 03/08/2021 4/14/2021 04/23/2021 nickt See master permit for interior lighting comcheck 05/12/2021 nickt 4/14/2021 04/23/2021 nickt 4/14/2021 4/14/2021 04/23/2021 nickt 4/14/2021 4/14/2021 05/12/2021 nickt