These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
0068.2019.ARBK
William J Parker Estate
610 S West End Unit F304
273718267076
Dwelling Separation Required - 2015 IBC
-708 Fire Partitions, 711 Horizontal Assemblies:
Walls and floor/ceilings separating dwelling units shall have a fire-resistance
rating of at least 1 hour. Walls shall extend from the top of the floor assembly
below to the underside of the floor or roof slab or deck above or to the
fire-resistance-rated floor/ceiling assembly above.
-714: Penetrations must be protected by a through-penetration firestop
system. Recessed fixtures shall not reduce the required fire resistance by use
of a listed fixture, a listed firehood, or a drywall assembly meeting the required
fire resistance. Exhaust fans require ceiling radiation damper.
-1207 Sound Transmission: Separating walls and floor/ceilings shall have an
STC rating of at least 50. Floor/ceilings shall have an IIC rating of at least 50.
2015 IBC 601 Fire Resistive Requirements for
Type of Construction: ____
Primary Structural Frame: ____hr
(columns, beams, girders, etc)
Exterior Bearing Walls: ____hr
Interior Bearing Walls: ____hr
Floors/Ceilings: ____hr
Roof : ____hr
Unless noted otherwise for occupancy separation or fire
separation distance.
VA
1
1
1
1
1
SMOKE ALARMS AND
CARBON MONOXIDE
DETECTORS REQUIRED
THROUGHOUT DWELLING
UNIT PER CITY OF ASPEN
MUNICIPAL CODE 8.15
03/29/2019
Per this project’s asbestos inspection report, your project
does not require a State asbestos abatement permit.
However, the following OSHA regulation must be
strictly adhered to: Standard Title 29, Part 1910.134,
1910.1001, and 1926.1101 of the Code of Federal
Regulations. It is recommended that you familiarize
yourself with these regulations and have a certified
General Abatement Contractor (GAC) conduct the removal
of the Asbestos Containing Material (ACM) under
engineering controls and that once the removal process is
completed, a visual inspection and clearance air
monitoring be conducted by an independent, certified Air
Monitoring Specialist. Furthermore, identified ACM may
be in areas which were either not covered in the scope of
the asbestos inspection or were inaccessible or hidden
due to their application during the construction process
and their subsequent enclosure or covering with building
and finish materials. These areas should be inspected
when renovation or demolition activities are scheduled
which may disturb the materials within, or beneath these
barriers.
READ THIS OR FAIL YOUR INSPECTION!
Furred & Dropped Ceilings, Soffits, and Walls
20015 IBC 803.13
This applies to the attachment of finishes or furring to any
assemblies that are required to be either fire-rated or
non-combustible and is separate from the fire-rated
assembly requirement.
Walls, Ceilings & Soffits: If furred 1 ¾ inches or
less, do one of the following:
4.Fill spaces with Class A material.
5.Fill spaces with inorganic or non-combustible material.
6.Fire block 8 feet in all directions.
Walls: If set out (furred) greater than 1 ¾ inches,
do one of the following:
4.Use a Class A finish material (such as drywall).
5.Use non-combustible framing.
6.Protect both sides with fire sprinklers.
Ceilings & Soffits: If dropped (furred) greater
than 1 ¾ inches:
Framing members, hangers, and other assembly
members must be non-combustible. You may not
use wood.
In Type III and V construction only, you may use fire
retardant treated wood or non-combustible framing.
05/
1
7
/
2
0
1
9
nic
k
t
Code Editions
Fire Sprinkler System
Type Of Construction Fire Alarms Installed
Required Special Inspections
Energy Code Compliance
Exterior Energy Use Total Approved On-Site Snowmelt________ Spa_______ Pool _________
Building Type/Occupancy Group
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING DESCRIPTION FORM - IRC & IBC
CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611
BUILDING CODE INFORMATION
2015 IRC
Existing?NFPA 13 NFPA 13 R
High-Strength Bolting Epoxy Anchors Structual Steel Welding
Permanent Micropiles Other _____________
Prescriptive Table
UNIT DESCRIPTION AS PROPOSED
# Stories Above Grade ______ # Stories Below Grade _______
Parking Spaces ______ Parking Spaces ______ Parking Spaces ______
# Bedrooms ______ # Full Baths ______ Deck Area ______
# 3/4 Baths ______ # 1/2 Baths ______
# Kitchens ______ # Wood Fireplaces ______
# Gas Appliances ______ # Gas Logs______
NFPA 13 D
RESCheck UA Alternative
Yes No
One Family Two Family
Townhouse
Reviewed By: _____________________Date:__________
BUILDING ROOMS AND USES BY LEVEL AS PROPOSED (Include Mechanical & Storage)
Basement ___________________________________________________________________________________
___________________________________________________________________________________________
Main Level __________________________________________________________________________________
____________________________________________________________________________________________
2nd Floor ___________________________________________________________________________________
__________________________________________________________________________________________
3rd Floor ___________________________________________________________________________________
___________________________________________________________________________________________
Additional ___________________________________________________________________________________
___________________________________________________________________________________________
Attached Garage Detached Garage Carport
Is there an ADU? # Living Rooms_____# Kitchens _____# Full Baths _____# 3/4 Baths _____# 1/2 Baths _____# Bedrooms _____
# Other Rooms (List)____________
ADU BUILDING DESCRIPTION
YesNo
PERMIT NUMBER: _______________________________
(As Adopted and Amended)
Other (Please Explain)
_________________
_________________
VA VB IV IIIA IIIB IIA IIB IA IB
Sprayed Fire-Resistants
COMCheck UA Alternative
(Existing + New)
A__B
B (A <50)F__H__I __
E R__S__
UM IRC
IBC
2015 IBC
(As Adopted and Amended)
YesNo Required?YesNo Type
January 2018
2015 IEBC
(As Adopted and Amended)
Other _____________
Gross Area of Building: __________ Gross Area of Unit: __________
Occupant Load: ___________
0068.2019.ARBK
n n
1227
3
3 3 3
0 0
1 1
0 0
letter of completion
NT 5/17/19
03/29/2019
2
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT CONTACT SHEET
CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611
___________________________________ _____________________ _____________________
________________________________________ __________________ _________ ____________
_______________________________________________________________________________________
Name Phone Cell Phone
CityMailing Address
E-mailAddress
State ZIP
OWNER
___________________________________ _____________________ ________________________Name Phone E-mail
FOR PLAN REVIEW QUESTIONS
___________________________________ _____________________ ________________________Name Phone E-mail
FOR INSPECTION QUESTIONS
___________________________________ _____________________ _____________________
________________________________________ __________________ _________ ____________
_______________________________________________________________________________________
Name Phone Cell Phone
CityMailing Address
E-mailAddress
State ZIP
OWNER’S AUTHORIZED AGENT
___________________________________ _____________________ _____________________
________________________________________ __________________ _________ ____________
_______________________________________________________________________________________
Name Phone Cell Phone
CityMailing Address
E-mailAddress
State ZIP
APPLICATION BEST CONTACT
___________________________________ _____________________ _____________________
________________________________________ __________________ _________ ____________
_______________________________________________________________________________________
Name Phone Cell Phone
CityMailing Address
E-mailAddress
State ZIP
ARCHITECT OR DESIGNER OF RECORD
___________________________________ _____________________ _____________________
________________________________________ __________________ _________ ____________
_______________________________________________________________________________________
Name Phone Cell Phone
CityMailing Address
E-mailAddress
State ZIP
CIVIL ENGINEER OF RECORD
___________________________________ _____________________ _____________________
________________________________________ __________________ _________ ____________
_______________________________________________________________________________________
Name Phone Cell Phone
CityMailing Address
E-mailAddress
State ZIP
STRUCTUAL ENGINEER OF RECORD
I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and
ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not
presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance
of construction. It is my responsibility to review the approved plans and any comments that are contained thereon and see that the
structure and/or project is built in compliance with all applicable codes.
________________________________________________________ _____________________ContractorSignature Date
INSPECTIONS: The General Contractor must schedule inspections online. Please visit www.aspenpitkin.com/Departments/Community-Development-Forms/ to do so.
___________________________________ _____________________ _____________________
________________________________________ __________________ _________ ____________
_______________________________________________________________________________________
Name Phone Cell Phone
CityMailing Address
E-mailAddress
State ZIP
GENERAL CONTRACTOR
Check if you are a tested owner builder (single-family homes only). You must take a test and complete the owner/building affidavit.
(CITY USE ONLY) Owner builder approved by:________________________Date:______________________ Affidavit on file
ADDRESS: ____________________________PERMIT NUMBER: _______________________________
August 2017
610 WEST END ST.
ANNE GRICE ANNE@ANNEGRICE.COM
WILLIAM A. PARKER JR. ESTATE
STEVE CARROLL
4401 NORTHSIDE PARKWAY SUITE 120 ATLANTA GA 30327
Steve.Carroll@genspring.com
ISOBEL PARKER MILLS
1790 GARRAUX PL. NW ATLANTA GA 30327
IBBYMILLS@GMAIL.COM
970-429-4148ANNE GRICE
408 ABC SUITE 201 ASPEN CO 81611
ANNE@ANNEGRICE.COM
970-925-8969ANDREW L. CALVETTI, P.E.
914 E. WATERS AVE. #18 ASPEN CO 81611
ALCEENGRG@AOL.COM
7/2/19
07/03/2019
Pete Waaraniemi (Janckila Const)
07/16/2019
NO EXTERIOR LIGHTING IN SCOPE OF
PERMIT. EXTERIOR SCOPE LIMITED
TO CHANGES IN FENESTRATION.
COMMUNITY DEVELOPMENT DEPARTMENT
BUILDING PERMIT APPLICATION
CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611
PROPERTY INFORMATION
___________________________________ _________ ___________________________
______________ ______________ ________________________________________
_________________________ _______________ __________________________________
________________________ _______________ __________________________________
CommericalMulti-FamilySingle Family
Use of Building Class of WorkNewAdditionAlterationRepair
________
YesNo
Will there be any roof/wall penetrations?
NOTICE: This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended or abandoned for a period of 180 days at any time after work is commenced.
_______________
_______________
_______________ _______________ _______________
_______________
_______________ _______________
_______________
PROJECTVALUATION
SQ FT OF BUILDING WORK AREA
UNIT SQ FT
SQ FT OF SOILDISTURBANCE
BUILDING FOOTPRINT
LOT SIZE(SQ FT)
PROJECT DETAILS (READ DEFINITIONS BELOW)
Mixed-Use IFFRTenant FinishDemolitionChange Order
________
ADDRESS UNIT #PARCEL ID #
BLOCK TRACT OR SUBDIVISIONLOT
DESCRIPTION OF WORK IN DETAIL
Building
Review
Building
Permit Fee Parks Impact
Engineering
Review
Zoning
Review (50%)
School Lands
Dedication
Zoning Review (50%)CMP (50%)TDM Impact
Energy Code
Review
REMP
Payment
Pedestrian
Amenity
CMP (50%)GIS Housing Cash in Lieu
Parks Review City Use
Tax Water Tap
Utility Review County UseTax Sanitation
SUBMITTAL FEES ISSUANCE FEES
APPROVALS
ISSUANCE FEES
BEST CONTACTNAME CELL EMAIL
OWNER NAME CELL EMAIL
____Toilets, Bidets ____Bathtub____Lavatory (Wash Basin)____Shower____Kitchen Sink (+Disposal)____Dishwasher____Laundry Bar, Utility Sink____Clothes Washer ____Floor Sink____Floor Drain____Water Heater (Pan Req)____# Gas Outlets____Water Treatment____Other_________
Fixture Counts Important Review Triggers
PC
Zoning
HPC
Building
Fire
Engineering
CMP
Water
Stormwater
Sanitation
Env. Health
Parks
Landscape
Efficiency
Approved
To Issue
Issuance
Date ApprovedReviewingDepartmentReviewerSign-Off
NEW SQ FT
Project Valuation: Cost of project as defined in Valuation Affadavit.Sq Ft of Building Work Area: Total square footage of interior area undergoing change or reconfiguration.Unit Sq Ft: Gross square footage, not FAR, of permitted unit.Lot Size: Total surveyed square footage of property.Sq Ft of Soil Disturbance: Exterior area of the lot where the ground is disturbedNew Sq Ft: Total added square footage for additions to net livable or net leasable space.Building Footprint: Grade floor square footage of the permitted structure.Hardscape Area: Square footage of impervious lot surface.Zone District: Underlying zone district of permitted parcel.
January 2019
DATE:___________ MASTER PERMIT:______________________ PERMIT NUMBER:__________________________
__________________________________________________________________________________
__________________________________________________________________________________
HARDSCAPEAREA
NeedsReview
DE
F
I
N
I
T
I
O
N
S
ZONEDISTRICT
Major Engineering Review• Projects involving less than 50% hardscape area and work affecting 75% or greater of unit sq ft• Projects involving greater than 50% hardscape area and work affecting 50% or greater of unit sq ft• Projects involving 1,000+ sq ft of soil disturbance area
Water Efficient Landscaping• Projects that trigger a major engineering review • Projects involving interior alterations affecting 50% or more of exisiting gross square footage
THIS SECTION MUST BE COMPLETED IN ITS ENTIRETY
0068.2019.ARBK
610 WEST END ST.F-304 273718267076
WILLIAM A. PARKER JR. ESTATE
ISOBEL PARKER MILLS 770-366-7442 ibbymills@gmail.com
INTERIOR REMODEL, REPLACING EXISTING WINDOWS & SLIDER DOORS
550,000
3
1n
4
n
n
3
1
1
0
1,383
1,383
N/A 1
0
N/A
1,383
N/A
0
0
N/A
R-15/L/PD
X LL 4/2/2019
X SV 07/16/19
X NT 5/17/19
X NT 5/17/19
8872.50 13650.00 X CK 7/3/19
325.00 X sw 4/4/2019
325.00 739.91 X pm 4/5/19
2047.50
739.91
4725.00
328.65 1375.00
03/29/2019
DAAM 7/16/19
5/10/2019 U340 - BXUV.U340 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U340 1/11
FIRE-RESISTANCE DESIGN
Assembly Usage Disclaimer
BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States
BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States Design Criteria and Allowable Variances
See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada Design Criteria and Allowable Variances
Design No. U340
April 15, 2019
Bearing Wall Rating — 1 Hr.
Finish Rating — See Item 2
This design was evaluated using a load design method other than the Limit States Design
Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States
Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or
BXUV7
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions
employing the UL or cUL Certification (such as Canada), respectively.
5/10/2019 U340 - BXUV.U340 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U340 2/11
HORIZONTAL SECTION
1. Wood Studs — Nom 2 by 4 in. alternating on opposite sides of nom 2 by 6 in.
wood plates. Spaced 24 in. OC max on each side of wood plates, staggered 12 in.
OC (or staggered equally if less than 24 in. OC) on opposite side.
2. Gypsum Board* — 5/8 in. thick gypsum board, paper or vinyl faced with beveled,
square, tapered or rounded edges. Gypsum board nailed to each stud 7 in. OC with
6d cement coated nails, 1-7/8 in. long, 0.0915 in. shank diam and 1/4 in. diam head.
As an alternate, No. 6 bugle head drywall screws, 1-7/8 in. long, may be substituted
for the 6d cement coated nails. When used in widths other than 48 in., gypsum
board to be installed horizontally.
When Steel Framing Members* (Item 5-5D) are used, gypsum board attached to
furring channels with 1 in. long Type S bugle-head steel screws spaced 12 in. OC.
AMERICAN GYPSUM CO — Types AG-C.
CERTAINTEED GYPSUM INC — Type FRPC (Finish rating 20 min), Type C.
CGC INC — Types C, IP-X2 (Finish rating 26 min).
CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C — Type LGFC-
C/A.
GEORGIA-PACIFIC GYPSUM L L C — Types 5 (Finish rating 26 min), DAPC, TG-
C.
NATIONAL GYPSUM CO — Types FSK-C, FSW-C, FSW-G.
5/10/2019 U340 - BXUV.U340 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U340 3/11
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type C or PG-C.
THAI GYPSUM PRODUCTS PCL — Type C.
UNITED STATES GYPSUM CO — Types C, IP-X2 (Finish rating 26 min).
2A. Gypsum Board* — (As an alternate to Item 2) — Nominal 5/8 in. thick, 4 ft.
wide panels, applied vertically to studs and bearing plates on one side of the
assembly with 1-5/8 in. long Type S screws spaced 12 in. OC at perimeter of panels
and 8 in. OC in the field. Horizontal joints of vertically applied panels need not be
backed by studs. Panel joints covered with paper tape and two layers of joint
compound. Screwheads covered with two layers of joint compound. Batts and
Blankets placed in stud cavity as described in Item 4B. Not evaluated for use with
Steel Framing Members, Furring Channels or Fiber, Sprayed.
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type QuietRock
530 (finish rating 23 min).
2B. Gypsum Board* — (As an alternate to Item 2) — 5/8 in. thick gypsum panels,
with beveled, square, or tapered edges, applied either horizontally or vertically.
Gypsum panels fastened to framing with 1-1/4 in. long Type W coarse thread
gypsum panel steel screws spaced a max 8 in. OC, with last screw 1 in. from edge
of board. When used in widths of other than 48 in., gypsum boards are to be
installed horizontally.
AMERICAN GYPSUM CO — Types AGX-1, M-Glass or AG-C, LightRoc
NATIONAL GYPSUM CO — Type FSK, Type FSK-G, Type FSW, Type FSW-3, Type
FSW-5, Type FSW-G, Type FSK-C, Type FSW-C, Type FSMR-C, Type FSW-6, Type
FSL
2C. Gypsum Board* — (As an alternate to Item 2) — Nominal 5/8 in. thick, 4 ft.
wide panels, applied vertically. Panels nailed 7 in. OC with 6d cement coated nails 1-
7/8 in. long, 0.0915 in. shank diam and 15/64 in. diam heads. Horizontal joints of
vertically applied panels to be backed by studs.
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type QuietRock
ES.
2D. Wall and Partition Facings and Accessories* — (As an alternate to Item 2) —
Nominal 5/8 in. thick, 4 ft. wide panels, applied vertically. Panels nailed 7 in. OC with
6d cement coated nails 1-7/8 in. long, 0.0915 in. shank diam and 15/64 in. diam
heads. Horizontal joints of vertically applied panels to be backed by studs.
5/10/2019 U340 - BXUV.U340 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U340 4/11
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type QuietRock
527.
2E. Gypsum Board* — (As an alternate to Item 2) — Any 5/8 in. thick UL
Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or
U305 — Nom. 5/8 in. thick gypsum board, paper or vinyl faced with beveled, square,
tapered or rounded edges. Gypsum board nailed to each stud 7 in. OC with 6d
cement coated nails, 1-7/8 in. long, 0.0915 in. shank diam and 1/4 in. diam head. As
an alternate, No. 6 bugle head drywall screws, 1-7/8 in. long, may be substituted for
the 6d cement coated nails. When used in widths other than 48 in., gypsum board to
be installed horizontally. Batts and Blankets placed in stud cavity as described in
Item 4B.
When Steel Framing Members* (Item 5) are used, gypsum board attached to
furring channels with 1 in. long Type S bugle-head steel screws spaced 12 in. OC.
ACADIA DRYWALL SUPPLIES LTD (View Classification) — CKNX.R25370
AMERICAN GYPSUM CO (View Classification) — CKNX.R14196
BEIJING NEW BUILDING MATERIALS PUBLIC LTD CO (View Classification) —
CKNX.R19374
CERTAINTEED GYPSUM INC (View Classification) — CKNX.R3660
CGC INC (View Classification) — CKNX.R19751
CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C (View
Classification) — CKNX.R18482
GEORGIA-PACIFIC GYPSUM L L C (View Classification) — CKNX.R2717
LOADMASTER SYSTEMS INC (View Classification) — CKNX.R11809
NATIONAL GYPSUM CO (View Classification) — CKNX.R3501
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM (View
Classification) — CKNX.R7094
PANEL REY S A (View Classification) — CKNX.R21796
5/10/2019 U340 - BXUV.U340 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U340 5/11
SIAM GYPSUM INDUSTRY (SARABURI) CO LTD (View Classification) —
CKNX.R19262
THAI GYPSUM PRODUCTS PCL (View Classification) — CKNX.R27517
UNITED STATES GYPSUM CO (View Classification) — CKNX.R1319
USG MEXICO S A DE C V (View Classification) — CKNX.R16089
2F. Gypsum Board* — (As an alternate to Item 2) — 5/8 in. thick gypsum panels,
with beveled, square, or tapered edges, applied either horizontally or vertically.
Gypsum panels fastened to framing with 1-1/4 in. long Type W coarse thread
gypsum panel steel screws spaced a maximum 10 in. OC with the last two screws 4
and 1 in. from the edges of the board. When used in widths other than 48 in.,
gypsum panels are to be installed horizontally.
CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C — Type LGFC6A
(finish rating 21 min), Type LGFC2A, Type LGFC-C/A, Type LGFC-WD, Type LGLLX
3. Joints and Nailheads — Gypsum board joints covered with tape and joint
compound. Nail heads covered with joint compound. As an alternate, nom 3/32 in.
thick gypsum veneer plaster may be applied to entire surface of Classified veneer
baseboard. Joints reinforced.
4. Batts and Blankets* — (Optional) — Any thickness glass or mineral fiber batt
insulation friction-fit into stud cavities.
See Batts and Blankets (BZJZ) category for list of Classified
companies.
4A. Fiber, Sprayed* — As an alternate to Batts and Blankets (Item 4) — Spray
applied cellulose material. The fiber is applied with water to completely fill the
enclosed cavity in accordance with the application instructions supplied with the
product with a nominal dry density of 2.7 lb/ft3. Alternate Application Method: The
fiber is applied without water or adhesive at a nominal dry density of 3.5 lb/ft3, in
accordance with the application instructions supplied with the product. When Item 5,
5A, 5B, 5C or 5D is used, Fiber, Sprayed shall be INS735, INS745, INS765LD or
INS770LD.
U S GREENFIBER L L C — INS735 & INS745 for use with wet or dry application.
INS510LD, INS515LD, INS541LD, INS735, INS745, INS765LD, and INS770LD are
to be used for dry application only.
5/10/2019 U340 - BXUV.U340 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U340 6/11
4B. Batts and Blankets* — (Required for use with Wall and Partition Facings and
Accessories, Item 2A and Gypsum Board Item 2E) — Glass fiber insulation, nom 3-
1/2 in. thick, min. density of 0.80 pcf, with a flame spread of 25 or less and a smoke
developed of 50 or less, friction-fitted to completely fill the stud cavities. See Batts
and Blankets Category (BKNV) for names of manufacturers.
4C. Fiber, Sprayed* — As an alternate to Batts and Blankets (Item 4) — Spray
applied cellulose fiber. The fiber is applied with water to completely fill the enclosed
cavity in accordance with the application instructions supplied with the product. The
minimum dry density shall be 4.30 lbs./ft3.
INTERNATIONAL CELLULOSE CORP — Celbar-RL
4D. Fiber, Sprayed* — As an alternate to Batts and Blankets (Item 4) — Spray-
applied cellulose material. The fiber is applied with water to completely fill the
enclosed cavity in accordance with the application instructions supplied with the
product. To facilitate the installation of the material, any thin, woven or non-woven
netting may be attached by any means possible to the outer face the studs. The
material shall reach equilibrium moisture content before the installation of materials
on either face of the studs. The minimum dry density shall be 5.79 lbs/ft3.
APPLEGATE HOLDINGS L L C — Type 1 SAFE Applegate Fired Rated Material
5. Steel Framing Members* — (Optional, Not Shown) — Furring channels and
Steel Framing Members as described below:
A. Furring Channels — Formed of No. 25 MSG galv steel. 2-9/16
in. or 2-23/32 in. wide by 7/8 in. deep, spaced 24 in. OC
perpendicular to studs. Channels secured to studs as described in
Item B. Ends of adjoining channels are overlapped 6 in. and tied
together with double strand of No. 18 SWG galv steel wire near
each end of overlap. As an alternate, ends of adjoining channels
may be overlapped 6 in. and secured together with two self-tapping
#6 framing screws, min. 7/16 in. long at the midpoint of the overlap,
with one screw on each flange of the channel. Gypsum board
attached to furring channels as described in Item 2.
B. Steel Framing Members* — Used to attach furring channels
(Item A) to studs (Item 1) . Clips spaced 48 in. OC., and secured to
studs with No. 8 x 2-1/2 in. coarse drywall screw through the center
grommet. Furring channels are friction fitted into clips. RSIC-1 clip
for use with 2-9/16 in. wide furring channels. RSIC-1 (2.75) clip for
use with 2-23/32 in. wide furring channels.
PAC INTERNATIONAL L L C — Types RSIC-1, RSIC-1 (2.75).
5A. Steel Framing Members* — (Optional, Not Shown) — Furring channels and
Steel Framing Members as described below:
5/10/2019 U340 - BXUV.U340 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U340 9/11
9. Mineral and Fiber Board* — (Optional, Not Shown) — For use with Items 9A-9D
— For optional use as an additional layer on one side of wall. Nom 1/2 in. thick, 4 ft.
wide with long dimension parallel and centered over studs. Attached to studs and
top and bottom bearing plates with minimum 1-3/8 in. long ring shanked nails or 1-
1/4 in. long Type W steel screws, spaced 12 in. OC and 24 in. OC along all
intermediate framing. The required UL Classified gypsum board layer (Item 9D) is to
be installed over the Mineral and Fiber Boards. Glass Fiber Insulation, Item 9A, or
Batts and Blankets, Item 9B, and Adhesive, Item 9C, are required.
HOMASOTE CO — Homasote Type 440-32
9A. Glass Fiber Insulation* — (For use with Item 9) 5-1/2 in. thick glass fiber batts
bearing the UL Classification Marking as to Surface Burning and/or Fire Resistance,
placed to completely fill the interior of the wall. See Batts and Blankets (BKNV or
BZJZ) categories for names of Classified companies.
9B. Batts and Blankets* — (As an alternate to Item 9A, For use with Item 9), 5-1/2
in. thick mineral wool batts, placed to completely fill interior of wall.
THERMAFIBER INC — Type SAFB, SAFB FF
9C. Adhesive — (For use with Item 9) — Construction grade adhesive applied in
vertical, serpentine, nominal 3/8 in. wide beads down the length of both vertical
edges of Mineral and Fiber Board (Item 9).
9D. Gypsum Board* — (For use with Item 9) — 5/8 in. thick, 4 ft. wide, applied
vertically over Mineral and Fiber Board (Item 9) with vertical joints located anywhere
over stud cavities. Secured to mineral and fiber boards with 1-1/2 in. Type G Screws
spaced 8 in. OC along edges of each vertical joint and 12 in. OC in intermediate field
of the Mineral and Fiber Board (Item 9). Secured to outermost studs and bearing
plates with 2 in. long Type S screws spaced 8 in. OC. Gypsum Board joints covered
with paper tape and joint compound. Screw heads covered with joint compound.
Finish Rating 30 Min.
AMERICAN GYPSUM CO — Type AG-C
CERTAINTEED GYPSUM INC — FRPC, Type C
CGC INC — Types C, IP-X2, IPC-AR
CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C — Type LGFC-
C/A
GEORGIA-PACIFIC GYPSUM L L C — Types 5, DAPC, TG-C
05/
1
7
/
2
0
1
9
nic
k
t
5/10/2019 U309 - BXUV.U309 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U309 1/13
FIRE-RESISTANCE DESIGN
Assembly Usage Disclaimer
BXUV - Fire Resistance Ratings - ANSI/UL 263 Certified for United States
BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada
See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United States Design Criteria and Allowable Variances
See General Information for Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada Design Criteria and Allowable Variances
Design No. U309
April 15, 2019
Bearing Wall Rating — 1 Hr.
Finish Rating — See Items 2, 2A and 2B
This design was evaluated using a load design method other than the Limit States Design
Method (e.g., Working Stress Design Method). For jurisdictions employing the Limit States
Design Method, such as Canada, a load restriction factor shall be used — See Guide BXUV or
BXUV7
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions
employing the UL or cUL Certification (such as Canada), respectively.
5/10/2019 U309 - BXUV.U309 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U309 2/13
1. Wood Studs — Nom 2 by 4 in., spaced 24 in. OC effectively firestopped.
2. Gypsum Board* — 5/8 in. thick, 4 ft wide, applied either horizontally or vertically,
nailed to studs and bearing plates with 6d cement coated nails min. 1-7/8 in. long,
0.0915 in. shank diam and 1/4 in. diam heads spaced 7 in. OC. Finish Rating 27
Min. When used in widths other than 48 in., gypsum board to be installed
horizontally.
When Steel Framing Members* (Items 5, 5A, 5B, 5C, or 5D) are
used, wallboard attached to furring channels with 1 in. long Type S
bugle-head steel screws spaced 12 in. OC.
When Item 6, resilient channels are used, 5/8 in. thick, 4 ft wide
applied vertically. Screw attached furring channels with 1 in. long,
self-drilling, self-tapping Type S or S-12 steel screws spaced 8 in.
OC, vertical joints located midway between studs.
ACADIA DRYWALL SUPPLIES LTD — Type X, 5/8 Type X, Type
Blueglass Exterior Sheathing
AMERICAN GYPSUM CO — Types AGX-1, M-Glass, AG-C,
LightRoc
BEIJING NEW BUILDING MATERIALS PUBLIC LTD CO — Type
DBX-1
CERTAINTEED GYPSUM INC — Type X, Type X-1, Types EGRG,
GlasRoc, GlasRoc-2, Type C
CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C
— Types LGFC6A, LGFC2A, LGFC-C/A, LGCF-WD, LGLLX, CLLX
5/10/2019 U309 - BXUV.U309 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U309 3/13
GEORGIA-PACIFIC GYPSUM L L C — Types 5, 6, 9, C, DAP, DD,
DA, DAPC, DGG, DS, GPFS6, LS (finish rating 23 min), Type X,
Veneer Plaster Base - Type X, Water Rated - Type X, Sheathing -
Type X, Soffit - Type X, TG-C, Type LWX, Veneer Plaster Base-
Type LWX, Water Rated-Type LWX, Sheathing Type-LWX, Soffit-
Type LWX, Type DGLW, Water Rated-Type DGLW, Sheathing
Type- DGLW, Soffit-Type DGLW, Type LW2X, Veneer Plaster Base
- Type LW2X, Water Rated - Type LW2X, Sheathing - Type LW2X,
Soffit - Type LW2X, Type DGL2W, Water Rated - Type DGL2W,
Sheathing - Type DGL2W
NATIONAL GYPSUM CO — Types -eXP-C, FSK, FSK-C, FSW,
FSW-3, FSW-5, FSW-C, FSW-G, FSMR-C, FSW-6 (finish rating 20
min), FSL, FSW-8
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM —
Type C, PG-9, PG-11, PG-C, PGS-WRS
PANEL REY S A — Types GREX, PRC, PRC2, PRX, RHX, MDX,
ETX
SIAM GYPSUM INDUSTRY (SARABURI) CO LTD — Type EX-1
THAI GYPSUM PRODUCTS PCL — Type X, Type C
2A. Gypsum Board* — (As an alternate to Item 2, Not Shown) — Nominal 5/8 in.
thick, 4 ft wide panels, applied vertically to studs and bearing plates on one side of
the assembly with 1-5/8 in. long Type S screws spaced 12 in. OC at perimeter of
panels and 8 in. OC in the field. Horizontal joints of vertically applied panels need
not be backed by studs. Panel joints covered with paper tape and two layers of joint
compound. Screwheads covered with two layers of joint compound. Batts and
Blankets placed in stud cavity as described in Item 4E. Not evaluated for use with
Steel Framing Members, Furring Channels or Fiber, Sprayed.
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type QuietRock
530 (finish rating 23 min)
2B. Gypsum Board* — (As an alternate to Item 2) — 5/8 in. thick gypsum panels,
with square edges, applied either horizontally or vertically. Gypsum panels fastened
to framing with 1-1/4 in. long Type W coarse thread gypsum panel steel screws
spaced a max 8 in. OC, with last two screws 1 and 4 in. from edge of board or nailed
to studs and bearing plates with 6d cement coated nails 1-7/8 in. long, 0.0915 in.
5/10/2019 U309 - BXUV.U309 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U309 4/13
shank diam and 1/4 in. diam heads spaced 7 in. OC. When used in widths of other
than 48 in., gypsum boards are to be installed horizontally.
GEORGIA-PACIFIC GYPSUM L L C — Type DGG, GreenGlass Type X (finish
rating 23 min).
2C. Gypsum Board* — (As an alternate to Item 2) — 5/8 in. thick, 4 ft. wide, paper
surfaced applied vertically only and secured as described in Item 2.
GEORGIA-PACIFIC GYPSUM L L C — Type X ComfortGuard Sound Deadening
Gypsum Board (finish rating 27 min)
NATIONAL GYPSUM CO — SoundBreak XP Type X Gypsum Board
2D. Gypsum Board* — (As an alternate to Items 2 through 2C) — Nominal 5/8 in.
thick, 4 ft wide panels, applied vertically and secured as described in Item 2.
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type QuietRock
ES
2E. Gypsum Board* — (As an alternate to Item 2) — 5/8 in. thick, 4 ft. wide, paper
surfaced applied vertically or horizontally and secured as described in Item 2 or 2K.
CERTAINTEED GYPSUM INC — Type SilentFX
2F. Gypsum Board* — (As an alternate to 5/8 in. Type FSW in Item 2) — 2 layers
nom. 5/16 in. thick gypsum panels applied vertically or horizontally. Horizontal joints
on the same side need not be staggered. Inner layer attached with fasteners, as
described in item 2, spaced 24 in. OC. Outer layer attached per Item 2.
NATIONAL GYPSUM CO — Type FSW
2G. Gypsum Board* — (As an alternate to Item 2) — 5/8 in. thick, 4 ft. wide,
applied vertically or horizontally with vertical joints centered over studs and
staggered one stud cavity on opposite sides of studs. Secured as described in Item
2 or 2K.
CERTAINTEED GYPSUM INC — 5/8" Easi-Lite Type X
THAI GYPSUM PRODUCTS PCL — 5/8" Easi-Lite Type X
2H. Wall and Partition Facings and Accessories* — (As an alternate to Item 2) —
Nominal 5/8 in. thick, 4 ft wide panels, applied vertically and secured as described in
Item 2.
5/10/2019 U309 - BXUV.U309 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U309 5/13
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type QuietRock
527.
2I. Gypsum Board* — (As an alternate to Item 2) — 5/8 in. thick gypsum panels,
with beveled, square, or tapered edges, applied either horizontally or vertically.
Gypsum panels fastened to framing with 1-1/4 in. long Type W coarse thread
gypsum panel steel screws spaced a maximum 10 in. OC with the last two screws 4
and 1 in. from the edges of the board. When used in widths other than 48 in.,
gypsum panels are to be installed horizontally.
CONTINENTAL BUILDING PRODUCTS OPERATING CO, L L C — Type LGFC6A
(finish rating 21 min), Type LGFC2A, Type LGFC-C/A, Type LGFC-WD, Type LGLLX
2J. Gypsum Board* — (As an alternate to Item 2) — 5/8 in. thick gypsum panels,
with beveled, square, or tapered edges, applied either horizontally or vertically.
Gypsum panels fastened to framing as described in Item 2 or with 1-1/4 in. long
Type W coarse thread gypsum panel steel screws spaced a max 8 in. OC, with last
screw 1 in. from edge of board. When used in widths of other than 48 in., gypsum
boards are to be installed horizontally. When square edge boards are used joint
treatment, Item 3, may be omitted.
AMERICAN GYPSUM CO — Types AGX-1, M-Glass, AG-C
NATIONAL GYPSUM CO — Type FSK, Type FSK-G, Type FSW, Type FSW-3, Type
FSW-5, Type FSW-G, Type FSK-C, Type FSW-C, Type FSMR-C, Type FSW-6, Type
FSL
2K. Gypsum Board* — (As an alternate to Item 2) — 5/8 in. thick gypsum panels,
with beveled, square, or tapered edges, applied either horizontally or vertically.
Gypsum panels fastened to framing with 1-1/4 in. long Type W coarse thread
gypsum panel steel screws spaced a max 8 in. OC, with last screw 1/2 in. from edge
of board. When used in widths of other than 48 in., gypsum boards are to be
installed horizontally.
CERTAINTEED GYPSUM INC — Type X, Type X-1, Types EGRG, GlasRoc,
GlasRoc-2, Type C
3. Joints and Fastener Heads — Wallboard joints covered with paper tape and joint
compound. Fastener heads covered with joint compound. Gypsum plaster not more
than 1/8 in. thick may be applied over the wallboard in addition to the specified joint
treatment.
4. Batts and Blankets* — (Not Shown) — Optional glass fiber insulation.
CERTAINTEED CORP
JOHNS MANVILLE
5/10/2019 U309 - BXUV.U309 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U309 9/13
Philips Modified Truss screws spaced 2-1/2 in. from the center of
the overlap. Gypsum board attached to resilient channels as
described in Item 3.
b. Steel Framing Members* — Used to attach resilient channels
(Item 5Da) to studs. Clips spaced 48 in. OC., and secured to studs
with No. 8 x 2-1/2 in. coarse drywall screw through the center hole.
Resilient channels are secured to clips with one No. 10 x 1/2 in.
pan-head self-drilling screw.
KEENE BUILDING PRODUCTS CO INC — Type RC+ Assurance
Clip
6. Furring Channel — Optional — Not Shown — For use on one side of the wall -
Resilient channels, 25 MSG galv steel, spaced vertically 24 in. OC, flange portion
screw attached to one side of studs with 1-1/4 in. long diamond shaped point, double
lead Phillips head steel screws. When resilient channels are used, insulation, Items
4C or 4D is required.
7. Wall and Partition Facings and Accessories* — (Optional, Not Shown) —
Nominal 1/2 in. thick, 4 ft wide panels, for optional use as an additional layer on one
or both sides of the assembly. Panels attached in accordance with manufacturer's
recommendations. When the QR-500 or QR-510 panel is installed between the
wood framing and the UL Classified gypsum board, the required UL Classified
gypsum board layer(s) is/are to be installed as indicated as to fastener type and
spacing, except that the required fastener length shall be increased by a minimum of
1/2 in. Not evaluated or intended as a substitute for the required layer(s) of UL
Classified Gypsum Board.
PABCO BUILDING PRODUCTS L L C, DBA PABCO GYPSUM — Type QuietRock
QR-500 and QR-510
8. Cementitious Backer Units* — (Optional Item Not Shown — For Use On Face
Of 1 Hr With All Standard Items Required) — 7/16 in., 1/2 in., 5/8 in., 3/4 in. or 1 in.
thick, min. 32 in. wide.- Applied vertically or horizontally with vertical joints centered
over studs. Fastened to studs and runners with cement board screws of adequate
length to penetrate stud by a minimum of 3/8 in. for steel framing members, and a
minimum of 3/4 in. for wood framing members spaced a max of 8 in. OC. When 4 ft.
wide boards are used, horizontal joints need not be backed by framing.
NATIONAL GYPSUM CO — Type DuraBacker, PermaBase, DuraBacker Plus, or
PermaBase Plus
9. Non-Bearing Wall Partition Intersection — (Optional) — Two nominal 2 by 4 in.
stud or nominal 2 by 6 in. stud nailed together with two 3in. long 10d nails spaced a
max. 16 in. OC. vertically and fastened to one side of the minimum 2 by 4 in. stud
with 3 in. long 10d nails spaced a max 16 in. OC. vertically. Intersection between
partition wood studs to be flush with the 2 by 4 in. studs. The wall partition wood
studs are to be framed by with a second 2 by 4 in. wood stud fastened with 3 in. long
5/10/2019 U309 - BXUV.U309 - UL Product Spec
productspec.ul.com/document.php?id=BXUV.U309 10/13
10d nails spaced a max. 16 in. OC. vertically. Maximum one non-bearing wall
partition intersection per stud cavity. Non-bearing wall partition stud depth shall be at
a minimum equal to the depth of the bearing wall.
10. Mineral and Fiber Board* — (Optional, Not Shown) — For optional use as an
additional layer on one side of wall. Nom 1/2 in. thick, 4 ft wide with long dimension
parallel and centered over studs. Attached to framing with 2 in. long Type W steel
screws, spaced 12 in. OC. The required UL Classified gypsum board layer(s) is/are
to be installed as indicated as to fastener type and spacing, except that the required
fastener length shall be increased by a minimum of 1/2 in. Not evaluated or intended
as a substitute for the required layer(s) of UL Classified Gypsum Board.
HOMASOTE CO — Homasote Type 440-32
10A. Mineral and Fiber Board* — (Optional, Not Shown) — For use with Items
10B-10E) — For optional use as an additional layer on one side of wall. Nom 1/2 in.
thick, 4 ft wide with long dimension parallel and centered over studs. Attached to
framing with minimum 1-3/8 in. long ring shanked nails or 1-1/4 in. long Type W steel
screws, spaced 12 in. OC along board edges and 24 in. OC in field of board along
intermediate framing. Not evaluated or intended as a substitute for the required
layer(s) of UL Classified Gypsum Board.
HOMASOTE CO — Homasote Type 440-32
10B. Glass Fiber Insulation — (For use with Item 10A) — 3-1/2 in. thick glass fiber
batts bearing the UL Classification Marking as to Surface Burning and/or Fire
Resistance, placed to fill the interior of the wall. See Batts and Blankets (BKNV or
BZJZ) categories for names of Classified companies.
10C. Batts and Blankets* — (As an alternate to Item 10B, For use with Item 10A),
3 in. thick mineral wool batts, placed to fill interior of wall, attached to the 3-1/2 in.
face of the studs with staples placed 24 in. OC.
ROCKWOOL — Type SAFEnSOUND
THERMAFIBER INC — Type SAFB, SAFB FF
10D. Adhesive — (For use with Item 10A) — Construction grade adhesive applied
in vertical, serpentine, nominal 3/8 in. wide beads down the length of both vertical
edges of Mineral and Fiber Board (Item 10A).
10E. Gypsum Board* — (For use with Item 10A) — 5/8 in. thick, 4 ft wide, applied
vertically over Mineral and Fiber Board (Item 10A) with vertical joints located
anywhere over stud cavities. Secured to mineral and fiber boards with 1-1/2 in. Type
G Screws spaced 8 in. OC along edges of each vertical joint and 12 in. OC in
intermediate field of the Mineral and Fiber Board (Item 10A). Secured to outermost
studs and bearing plates with 2 in. long Type S screws spaced 8 in. OC. Gypsum05/