Loading...
HomeMy WebLinkAboutFile Documents.600 E Main St.0036.2019 (10).ACBKThe City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK 04/23/2019 0036.2019.ACBK CONCEPT 600 CONDO ASSOCIATION 600 E MAIN ST 273707325800 05/09/2019 Page 10 of 27 -Table 3- Wind Resistance and Fire Classification- EverGuard® TPO and EverGuard Extreme® TPO Mechanically Secured to Insulated Combustible Roof Decks SYSTEM NO DECK FIRE BARRIER1 INSULATION1 COVER BOARD1 ROOF COVER FIRE RATING UL 790 / E108 ALLOWABLE WIND UPLIFT Membrane Fasteners and Plates Min. Lap Width Min. Weld Width Max. Lap Spacing Max. Fastener Spacing C-1 Min. 15/32 in. Plywood or 1 in. Wood Plank VersaShield® Solo™ Fire Resistant Slip Sheet -OR- Min. ¼” thick Dens Deck®, SECUROCK® Gypsum-Fiber Roof Board or SECUROCK® Glass- Mat Roof Board -OR- TOPCOAT® FireOut™ Fire Barrier Coating applied at 1 gal/sq (One or more of the following) Min. 0.5 in. thick EnergyGuard™, EnergyGuard™ RA, EnergyGuard™ RN or EnergyGuard™ Ultra Polyiso Insulation (Optional) Min. 0.25 in. thick Dens Deck®, SECUROCK® Gypsum-Fiber Roof Board, SECUROCK® Glass-Mat Roof Board, min. 0.5 in. thick EnergyGuard™ HD Polyiso Insulation, EnergyGuard™ HD Plus Polyiso Insulation, Structodek® High Density Fiberboard Roof Insulation, EnergyGuard™ Perlite Recover Board or min. 0.75 in. thick EnergyGuard™ Perlite Roof Insulation EverGuard® TPO -OR- EverGuard Extreme® TPO Drill-Tec™ 2 in. Double Barbed XHD, 2-3/8 in. Barbed XHD or Eyehook AccuSeam Plates and Drill-Tec™ #14 Fasteners 6 in. 1.5 in. 54 in. 9 in. Class A; 0.5:12 -30.0 psf C-2 Min. 19/32 in. Plywood or 1 in. Wood Plank 6 in. 1.5 in. 54 in. 8 in. -45.0 psf C-3 Min. 15/32 in. Plywood or 1 in. Wood Plank Min. ¼” thick Dens Deck®, SECUROCK® Gypsum-Fiber Roof Board or SECUROCK® Glass- Mat Roof Board None None 6 in. 1.5 in. 54 in. 9 in. Class A; 2.5:12 -30.0 psf C-4 Min. 19/32 in. Plywood or 1 in. Wood Plank None None 6 in. 1.5 in. 54 in. 8 in. -45.0 psf C-5 Min. 19/32 in. Plywood or 1 in. Wood Plank None (Optional, one or more of the following) Min. 0.5 in. thick EnergyGuard™, EnergyGuard™ RA, EnergyGuard™ RN or EnergyGuard™ Ultra Polyiso Insulation Min. 0.25 in. thick Dens Deck®, SECUROCK® Gypsum-Fiber Roof Board, SECUROCK® Glass-Mat Roof Board 6 in. 1.75 in. 54 in. 6 in. -52.5 psf 1) The fire barrier (when present), insulation and cover board (when present) shall be preliminarily secured per manufacturer’s installation instructions. 04/10/201905/21/2019 justinh 04/10/201905/21/2019 justinh 04/10/201905/21/2019 justinh 04/10/2019 0036.2019.ACBK X X XX X X X PL 5.7.2019 535.00 535.00 2,500.00 25.00 265.00 63.00 JRB 5/9/19 0 0 0 0 0 C-1 JH 5/21/19 JH 5/21/19 04/10/2019 05/21/2019 justinh PleaseprovideSpecsTPO 04/18/2019DAM 6/5/19 PH 5/22/19