HomeMy WebLinkAboutFile Documents.600 E Main St.0036.2019 (10).ACBKThe City of Aspen
These plans must be kept at the
building site or inspection
delays may occur. Construction
shall conform to these plans. All
changes shall be approved by
the building official.
Field Plan Set Must Be Printed In Color
SEPARATE PERMITS ARE
REQUIRED FOR ELECTRICAL,
PLUMBING, MECHANICAL, OR
FIRE SPRINKLER WORK
04/23/2019
0036.2019.ACBK
CONCEPT 600 CONDO ASSOCIATION
600 E MAIN ST
273707325800
05/09/2019
Page 10 of 27
-Table 3- Wind Resistance and Fire Classification-
EverGuard® TPO and EverGuard Extreme® TPO Mechanically Secured to Insulated Combustible Roof Decks
SYSTEM
NO DECK FIRE BARRIER1 INSULATION1 COVER BOARD1
ROOF COVER FIRE
RATING
UL 790 /
E108
ALLOWABLE
WIND UPLIFT
Membrane Fasteners and
Plates
Min.
Lap
Width
Min.
Weld
Width
Max.
Lap
Spacing
Max.
Fastener
Spacing
C-1
Min. 15/32 in.
Plywood
or 1 in. Wood
Plank
VersaShield® Solo™
Fire Resistant Slip
Sheet
-OR-
Min. ¼” thick Dens
Deck®, SECUROCK®
Gypsum-Fiber Roof
Board or
SECUROCK® Glass-
Mat Roof Board
-OR-
TOPCOAT® FireOut™
Fire Barrier Coating
applied at 1 gal/sq
(One or more of the
following)
Min. 0.5 in. thick
EnergyGuard™,
EnergyGuard™ RA,
EnergyGuard™ RN or
EnergyGuard™ Ultra
Polyiso Insulation
(Optional)
Min. 0.25 in. thick Dens Deck®,
SECUROCK® Gypsum-Fiber Roof
Board, SECUROCK® Glass-Mat
Roof Board, min. 0.5 in. thick
EnergyGuard™ HD Polyiso
Insulation, EnergyGuard™ HD
Plus Polyiso Insulation,
Structodek® High Density
Fiberboard Roof Insulation,
EnergyGuard™ Perlite Recover
Board or min. 0.75 in. thick
EnergyGuard™ Perlite Roof
Insulation EverGuard®
TPO
-OR-
EverGuard
Extreme®
TPO
Drill-Tec™ 2 in.
Double Barbed XHD,
2-3/8 in. Barbed XHD
or Eyehook
AccuSeam Plates and
Drill-Tec™ #14
Fasteners
6 in. 1.5 in. 54 in. 9 in.
Class A;
0.5:12
-30.0 psf
C-2
Min. 19/32 in.
Plywood
or 1 in. Wood
Plank
6 in. 1.5 in. 54 in. 8 in. -45.0 psf
C-3
Min. 15/32 in.
Plywood
or 1 in. Wood
Plank
Min. ¼” thick Dens
Deck®, SECUROCK®
Gypsum-Fiber Roof
Board or
SECUROCK® Glass-
Mat Roof Board
None None 6 in. 1.5 in. 54 in. 9 in.
Class A;
2.5:12
-30.0 psf
C-4
Min. 19/32 in.
Plywood
or 1 in. Wood
Plank
None None 6 in. 1.5 in. 54 in. 8 in. -45.0 psf
C-5
Min. 19/32 in.
Plywood
or 1 in. Wood
Plank
None
(Optional, one or
more of the following)
Min. 0.5 in. thick
EnergyGuard™,
EnergyGuard™ RA,
EnergyGuard™ RN or
EnergyGuard™ Ultra
Polyiso Insulation
Min. 0.25 in. thick Dens Deck®,
SECUROCK® Gypsum-Fiber Roof
Board, SECUROCK® Glass-Mat
Roof Board
6 in. 1.75 in. 54 in. 6 in. -52.5 psf
1) The fire barrier (when present), insulation and cover board (when present) shall be preliminarily secured per manufacturer’s installation instructions.
04/10/201905/21/2019
justinh
04/10/201905/21/2019
justinh
04/10/201905/21/2019
justinh
04/10/2019
0036.2019.ACBK
X
X
XX
X
X
X
PL 5.7.2019
535.00
535.00
2,500.00 25.00
265.00
63.00
JRB 5/9/19
0
0
0
0
0
C-1
JH 5/21/19
JH 5/21/19
04/10/2019
05/21/2019
justinh
PleaseprovideSpecsTPO
04/18/2019DAM 6/5/19
PH 5/22/19