Loading...
HomeMy WebLinkAboutFile Documents.210 S West End St.0011-2021-BCHO (21)The City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK 06/01/2021 Holesaw size (R) (diameter): 0 inches On Center Spacing (T): 0 inches % Open (30% minimum req'd): #DIV/0! Minimum required thickness of EPS/XPS insulation to get overall R-10:#DIV/0! inches Holesaw size (R) (diameter): 2.5 inches Vertical On Center Spacing (U1): 4 inches Horizontal On Center Spacing (U2): 4 inches % Open (30% minimum req'd): 30.7% Minimum required thickness of EPS/XPS insulation to get overall R-10: 2.61 inches City of Aspen V1 modified 1/25/2017 Pervious Snowmelt Insulation Perforation Calculator The City of Aspen has created and provided this software solely as a reference. Users should obtain assistance from a qualified professional to verify accuracy and applicability before proceeding. The City of Aspen makes no express or implied warranty with respect to this software or any information contained herein. To the full extent permissible by law, the City of Aspen disclaims all responsibility for any damages or losses (including, without limitation, structural damage, building defects, financial loss, damages for loss in business projects, loss of profits or other consequential losses) arising in contract, tort or otherwise from the use of or inability to use this software, or from any action or decision taken as a result of using this software. Sand with snowmelt tubing Pervious pavers 3" of insulation (R-15) with holes sized and spaced as calculated Screened rock below filter fabric example section detail Compacted road base 08/10/2021 SEE CIVIL SHEET C7 FOR CORRESPONDING DETAILING 08/31/2021 justinh External Energy Use Approved RREMP CREMP PERMIT #:_______________DATE:________ SNOWMELT:_____________________________ POOL: _____________________________ SPA: _____________________________ OFFSET:________________________________ REMP SHEET: __________________________ REVIEWED BY: _________________________ SNOWMELT SYSTEM AND EQUIPMENT MANDATORY REQ’S. All snowmelt systems shall meet the following: -Any portions in the Right of Way must be on a separate zone. A ROW permit and Permanent Encroachment License are required. -R10 insulation shall be installed under the area to be snow melted or R5 insulation shall be installed under and at the slab edges. (Ordinance 11 Series 2011) -Automatic controls installed for system shut off when pavement temperature is above 50°F and no precipitation is falling. (2009 IECC Sec. 403.8 & 503.2.4.5) -Automatic or manual controls installed for system shut off when outdoor temperature is above 40°F. (2009 IECC Sec. 403.8 & 503.2.4.5) -Inspection by testing hydrostatically at 1½ times max system design pressure, but not less than 100psi, for 15minutes. (2009 IMC Sec. 1208.1) MINIMUM BOILER AFUE: _________________ X 0011-2021-BCHO 8/31/21 761 SQ.FT. TOTAL (726 EXISTING, 35 NEW) A-002 94.4% NONE JH 08/31/2021 justinh SEE NOTES #1 PLANS