Loading...
HomeMy WebLinkAboutFile Documents.204 S Galena St.0053.2019 (5).ACBKThe City of Aspen These plans must be kept at the building site or inspection delays may occur. Construction shall conform to these plans. All changes shall be approved by the building official. Field Plan Set Must Be Printed In Color SEPARATE PERMITS ARE REQUIRED FOR ELECTRICAL, PLUMBING, MECHANICAL, OR FIRE SPRINKLER WORK 0053.2019.ACBK M DEVELOPMENT 204 S GALENA UNIT C 273707340001 07/01/2019 COMcheck Software Version 4.1.1.0 Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:Alteration Construction Site: 204 South Galena Street Aspen, CO 81611 Owner/Agent:Designer/Contractor: Randall A. Nelson, P.E. Acertus Consulting Group 14817 W. 95th St. Lenexa, KS 66215 Project Information Energy Code: Lululemon Athletica Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Sales Floor (New) (Retail:Sales Area)351 1.59 558 1.40 491 (b)Allowance: Furniture, clothing, cosmetics highlighting / Fix. ID: T1-R/TL1 (New)351 (a) 2-Fit Rooms (Retail:Dressing/Fitting Room)362 0.71 257 3-Office (Common Space Types:Office - Enclosed): Exempt 4-Restroom/Mop (Common Space Types:Restrooms): Exempt 5-Break Room (Common Space Types:Lounge/Breakroom): Exempt 6-Storage Area (Common Space Types:Storage): Exempt 7-Sales Floor (Existing) (Retail:Sales Area): Exempt 1415Total Allowed Watts = 109Supplemental Allowed Watts (null) = (a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s) are specified. (b)Allowance is (B x C) or the actual wattage of the fixtures given in Proposed Power section, whichever is less. (c)Supplemental watts must be associated with retail merchandise highlighting fixtures. Area Category Exemption Qualifications Activity Area # Fixtures Repl./AddedPre-Alt.null Total # Watts Pre-Alt.Post-Alt. Office ( Common Space Types:Office - Enclosed 54 sq.ft.) Exemption: Replacement of bulbs and ballasts only. 24.000 24.000 Restroom/Mop ( Common Space Types:Restrooms 57 sq.ft.) Exemption: Replacement of bulbs and ballasts only. 59.000 59.000 Break Room ( Common Space Types:Lounge/Breakroom 157 sq.ft.) Exemption: Replacement of bulbs and ballasts only. 72.000 72.000 Storage Area ( Common Space Types:Storage 297 sq.ft.) Exemption: Replacement of bulbs and ballasts only. 448.000 448.000 Sales Floor (Existing) ( Retail:Sales Area 847 sq.ft.) Exemption: Replacement of bulbs and ballasts only. 84.000 82.000 Proposed Interior Lighting Power Project Title: Data filename: Lululemon Athletica G:\Lululemon\1920142 Lululemon - Aspen, CO (South Galena)\Energy\Lululemon - Aspen, CO 2015 IECC.cck 07/16/19Report date: 61 ofPage07/19/2019 Owner/Agent:M Development2001 N. Halsted St. #304Chicago, IL 60614Contact: Jeff RichmanOwner's Agent: Vanessa GarciaMenemsha Solutions 07/29/2019 justinh E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Sales Floor (New) ( Retail:Sales Area 351 sq.ft.) Track lighting 5: T1-R/TL1 (New): Curcuit L-11,b: Wattage based on current limiting device capacity 0 0 600 600 LED 13: RF3-S: LED Recessed Downlight: Other:1 7 20 140 Fit Rooms ( Retail:Dressing/Fitting Room 362 sq.ft.) LED 9: D5: Fit Room Mirror 100W Driver: Other:1 5 100 Exempt Exemption:Lighting Integral to Equipment LED 10: LS1: Fit Room LED Tape 100W Driver: Other:1 1 100 100 LED 11: LS1: Fit Room LED Tape 300W Driver: Other:1 1 300 300 LED 12: RF3-S: LED Recessed Downlight: Other:1 6 20 120 LED 1: D1: LED Pendant: Other:1 1 18 18 LED 2: D2: LED Pendant: Other:1 1 6 6 Office ( Common Space Types:Office - Enclosed 54 sq.ft.): Exempt Restroom/Mop ( Common Space Types:Restrooms 57 sq.ft.): Exempt Break Room ( Common Space Types:Lounge/Breakroom 157 sq.ft.): Exempt Storage Area ( Common Space Types:Storage 297 sq.ft.): Exempt Sales Floor (Existing) ( Retail:Sales Area 847 sq.ft.): Exempt 1284Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: Lululemon Athletica G:\Lululemon\1920142 Lululemon - Aspen, CO (South Galena)\Energy\Lululemon - Aspen, CO 2015 IECC.cck 07/16/19Report date: 62 ofPage Matt Nelson - Electrical Designer 07/16/19 07/19/2019 07/29/2019 justinh Code Editions Fire Sprinkler System Type Of Construction Fire Alarms Installed Required Special Inspections Energy Code Compliance Exterior Energy Use Total Approved On-Site Snowmelt________ Spa_______ Pool _________ Building Type/Occupancy Group COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DESCRIPTION FORM - IRC & IBC CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 BUILDING CODE INFORMATION 2015 IRC Existing?NFPA 13 NFPA 13 R High-Strength Bolting Epoxy Anchors Structual Steel Welding Permanent Micropiles Other _____________ Prescriptive Table UNIT DESCRIPTION AS PROPOSED # Stories Above Grade ______ # Stories Below Grade _______ Parking Spaces ______ Parking Spaces ______ Parking Spaces ______ # Bedrooms ______ # Full Baths ______ Deck Area ______ # 3/4 Baths ______ # 1/2 Baths ______ # Kitchens ______ # Wood Fireplaces ______ # Gas Appliances ______ # Gas Logs______ NFPA 13 D RESCheck UA Alternative Yes No One Family Two Family Townhouse Reviewed By: _____________________Date:__________ BUILDING ROOMS AND USES BY LEVEL AS PROPOSED (Include Mechanical & Storage) Basement ___________________________________________________________________________________ ___________________________________________________________________________________________ Main Level __________________________________________________________________________________ ____________________________________________________________________________________________ 2nd Floor ___________________________________________________________________________________ __________________________________________________________________________________________ 3rd Floor ___________________________________________________________________________________ ___________________________________________________________________________________________ Additional ___________________________________________________________________________________ ___________________________________________________________________________________________ Attached Garage Detached Garage Carport Is there an ADU? # Living Rooms_____# Kitchens _____# Full Baths _____# 3/4 Baths _____# 1/2 Baths _____# Bedrooms _____ # Other Rooms (List)____________ ADU BUILDING DESCRIPTION YesNo PERMIT NUMBER: _______________________________ (As Adopted and Amended) Other (Please Explain) _________________ _________________ VA VB IV IIIA IIIB IIA IIB IA IB Sprayed Fire-Resistants COMCheck UA Alternative (Existing + New) A__B B (A <50) F__H__I __ E R__S__ UM IRC IBC 2015 IBC (As Adopted and Amended) YesNo Required?YesNo Type January 2018 2015 IEBC (As Adopted and Amended) Other _____________ Gross Area of Building: __________ Gross Area of Unit: __________ Occupant Load: ___________ 0053.2019.ACBK 2,222 SF8,229 SF 31 OCCUPANTS n 2 1 STORAGE MERCANTILE (RETAIL) JH 6/12/19 06/18/2019 FIRE SPRINKLERS REQUIRED 07/29/2019 justinh COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT APPLICATION CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 PROPERTY INFORMATION ___________________________________ _________ ___________________________ ______________ ______________ ________________________________________ _________________________ _______________ __________________________________ ________________________ _______________ __________________________________ CommericalMulti-FamilySingle Family Use of Building Class of WorkNewAdditionAlterationRepair ________YesNo Will there be any roof/wall penetrations? NOTICE: This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended or abandoned for a period of 180 days at any time after work is commenced. _______________ _______________ _______________ _______________ _______________ _______________ _______________ _______________ _______________ PROJECTVALUATION SQ FT OF BUILDING WORK AREA UNIT SQ FT SQ FT OF SOILDISTURBANCE BUILDING FOOTPRINT LOT SIZE(SQ FT) PROJECT DETAILS (READ DEFINITIONS BELOW) Mixed-Use IFFRTenant FinishDemolitionChange Order ________ ADDRESS UNIT #PARCEL ID # BLOCK TRACT OR SUBDIVISIONLOT DESCRIPTION OF WORK IN DETAIL Building Review Building Permit Fee Parks Impact EngineeringReview Zoning Review (50%)School Lands Dedication Zoning Review (50%) CMP (50%)TDM Impact Energy CodeReview REMPPayment Pedestrian Amenity CMP (50%)GIS Housing Cash in Lieu Parks Review City UseTax Water Tap Utility Review County Use Tax Sanitation SUBMITTAL FEES ISSUANCE FEES APPROVALS ISSUANCE FEES BEST CONTACTNAME CELL EMAIL OWNER NAME CELL EMAIL ____Toilets, Bidets ____Bathtub____Lavatory (Wash Basin)____Shower____Kitchen Sink (+Disposal)____Dishwasher____Laundry Bar, Utility Sink____Clothes Washer ____Floor Sink____Floor Drain____Water Heater (Pan Req)____# Gas Outlets____Water Treatment____Other_________ Fixture Counts Important Review Triggers PC Zoning HPC Building Fire Engineering CMP Water Stormwater Sanitation Env. Health Parks LandscapeEfficiencyApproved To Issue Issuance Date ApprovedReviewingDepartmentReviewerSign-Off NEW SQ FT Project Valuation: Cost of project as defined in Valuation Affadavit.Sq Ft of Building Work Area: Total square footage of interior area undergoing change or reconfiguration.Unit Sq Ft: Gross square footage, not FAR, of permitted unit.Lot Size: Total surveyed square footage of property.Sq Ft of Soil Disturbance: Exterior area of the lot where the ground is disturbedNew Sq Ft: Total added square footage for additions to net livable or net leasable space.Building Footprint: Grade floor square footage of the permitted structure.Hardscape Area: Square footage of impervious lot surface.Zone District: Underlying zone district of permitted parcel. January 2019 DATE:___________ MASTER PERMIT:______________________ PERMIT NUMBER:__________________________ __________________________________________________________________________________ __________________________________________________________________________________ HARDSCAPEAREA NeedsReview DE F I N I T I O N S ZONEDISTRICT Major Engineering Review• Projects involving less than 50% hardscape area and work affecting 75% or greater of unit sq ft• Projects involving greater than 50% hardscape area and work affecting 50% or greater of unit sq ft• Projects involving 1,000+ sq ft of soil disturbance area Water Efficient Landscaping• Projects that trigger a major engineering review • Projects involving interior alterations affecting 50% or more of exisiting gross square footage THIS SECTION MUST BE COMPLETED IN ITS ENTIRETY 0053.2019.ACBK 204 South Galena Street C 273707340001 B 94 CITY AND TOWNSITE OF ASPEN M DEVELOPMENT / JEFF RICHMAN 312-404-2321 jrichman@mdevco.com VANESSA GARCIA 310-263-3585 vgarcia@menemshasolutions.com Retail interior tenant improvement to include electrical, mechanical and plumbing. $135,000 0 0 0 n 0 0 0 0 2,222 SF 2,222 SF 9,000 SF 0 0 0 SF 0 SF 8,229 SF 0 0 0 0 1 771 SF ASPEN COMMERCIAL Bottle Filler X LL 6/18/2019 X JRB 7/1/19 X X JH 7/29/19 X JH 7/29/19 3185.00 4900.00 0 X ck 10/2/19 325.00 0 X sw 7/29/19 325.00 1188.77 0 X CS 6/25/19 735.00 0 1188.77 0 367.50 55.00 337.50 06/18/2019 SY 07/01/19 COMMUNITY DEVELOPMENT DEPARTMENT BUILDING PERMIT CONTACT SHEET CITY OF ASPEN 130 S. GALENA ST | ASPEN, CO 81611 ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP OWNER ___________________________________ _____________________ ________________________Name Phone E-mail FOR PLAN REVIEW QUESTIONS ___________________________________ _____________________ ________________________Name Phone E-mail FOR INSPECTION QUESTIONS ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP OWNER’S AUTHORIZED AGENT ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP APPLICATION BEST CONTACT ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP ARCHITECT OR DESIGNER OF RECORD ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP CIVIL ENGINEER OF RECORD ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP STRUCTUAL ENGINEER OF RECORD I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction. It is my responsibility to review the approved plans and any comments that are contained thereon and see that the structure and/or project is built in compliance with all applicable codes. ________________________________________________________ _____________________ContractorSignature Date INSPECTIONS: The General Contractor must schedule inspections online. Please visit www.aspenpitkin.com/Departments/Community-Development-Forms/ to do so. ___________________________________ _____________________ _____________________ ________________________________________ __________________ _________ ____________ _______________________________________________________________________________________ Name Phone Cell Phone CityMailing Address E-mailAddress State ZIP GENERAL CONTRACTOR Check if you are a tested owner builder (single-family homes only). You must take a test and complete the owner/building affidavit. (CITY USE ONLY) Owner builder approved by:________________________Date:______________________ Affidavit on file ADDRESS: ____________________________PERMIT NUMBER: _______________________________ August 2017 204 South Galena Street 0053.2019.ACBK 310-263-3585VANESSA GARCIA vgarcia@menemshasolutions.com 604-790-7227 ext. 54JORDAN SAUER jordan@vansnellenberg.com 312-850-1680M DEVELOPMENT 312-404-2321 2001 N. HALSTED STREET #304 CHICAGO IL 60614 jrichman@mdevco.com 310-263-3585VANESSA GARCIA 20521 EARL STREET TORRANCE CA 90503 vgarcia@menemshasolutions.com 310-263-3585VANESSA GARCIA 20521 EARL STREET TORRANCE CA 90503 vgarcia@menemshasolutions.com 310-263-3532REZA A. HADAEGH 310-469-1075 20521 EARL STREET TORRANCE CA 90503 rhadaegh@menemshasolutions.com N/A N/A Lennen Commercial Builders, Inc. 6/12/19 6/12/19 06/18/2019 BM 10/4/19 READ THIS OR FAIL YOUR INSPECTION! Furred & Dropped Ceilings, Soffits, and Walls 20015 IBC 803.13 This applies to the attachment of finishes or furring to any assemblies that are required to be either fire-rated or non-combustible and is separate from the fire-rated assembly requirement. Walls, Ceilings & Soffits: If furred 1 ¾ inches or less, do one of the following: 4.Fill spaces with Class A material. 5.Fill spaces with inorganic or non-combustible material. 6.Fire block 8 feet in all directions. Walls: If set out (furred) greater than 1 ¾ inches, do one of the following: 4.Use a Class A finish material (such as drywall). 5.Use non-combustible framing. 6.Protect both sides with fire sprinklers. Ceilings & Soffits: If dropped (furred) greater than 1 ¾ inches: Framing members, hangers, and other assembly members must be non-combustible. You may not use wood. In Type III and V construction only, you may use fire retardant treated wood or non-combustible framing. COMMERCIAL REFERENCES FROM 2015 IBC EU = enclosed usable space under stairs shall be 1-hr construction or stair enclosure rating. No access from stair enclosure.1011.7.3 SG = safety glazing required sec 2406 V = ventilation required, including from bathrooms. sec 1203.1, IMC 402 & 403 GR = guards, 42” min ht, 4” max opening sec 1015 HR = handrails 34”-38” ht sec 1014 AS = risers shall be solid in accessible egress stairs sec 1011.5.5.3 DS = Draft stopping / fire blocking 718 RD = Roof drainage 1503.4 STC = Sound transmission class not less than 50 at dwelling separations, sec 1207 PD = protect against decay, sec 2304.12 REFERENCES FROM 2015 IMC AS = access and service space for maintenance req’d, sec 306 MA = kitchen hood make up air required, sec 508 ET = exhausts terminate 3’ from prop line and openings, 10’ from intakes, 501.3.1 IT= intake openings 10’ from lot line & contaminant sources (vents, streets), 401.4 D = fasten and seal all ductwork per 603.9 REFERENCES FROM 2015 IFGC CA = combustion air not taken from bathrooms or storage, sec 303.3 REFERENCES FROM 2015 IECC F = new or replacement glazing U factors may not exceed: Fixed fenestration: U 0.29 Operable fenestration: U 0.37 Entrance doors: U 0.77 -Must have NFRC label or ASHRAE calcs, sec C402.4 REFERENCES FROM 2014 NEC EP = electric panel ‘happy space’ 30”x36”x78”, not in storage, sec 110.26 10/04/2019