Loading...
HomeMy WebLinkAboutFile Documents.210 S West End St.0111.2019 (37).ARBKRefrigerator UP C C B B A A 4 4 3 3 2 1 1 5 5 6 6 D D E DISTANCE FROM PROPERTY LINE TO NEW WALL GARAGE 5'-4" EAST HYMAN AVENUE CONCRETE WALK BACK OF CURB WEST END STREET BACK OF CURB C O N C R ETE W ALK STONE WALK DISTANCE FROM PROPERTY LINE TO EXISTING WALL PR OPE RTY LINE PR OPE RTY LINE PROPERTY LINE PROPERTY LINE CENTERLINE OF ALLEY NEW ADDITION DISTANCE FROM PROPERTY LINE TO NEW WALL (V.I.F.) 6'-5 1/16" DISTANCE FROM PROPERTY LINE TO NEW STONE VENEER PARKING EXIST RETAINING WALL TO REMAIN 4 NEW STEPS TO REPLACE 3 EXIST STEPS AND PLANTER EXIST STEPS EXIST PLANTER NEW STEEL COLUMNS - SET ON EXIST FOUNDATION RECONFIGURE EXISTING TERRACE EXISTING WATERFEATURE EXISTING SITE WALL SLOPE 1-HR WALL (LESS THAN 30' FROM PROPERTY LINE) 1-HR WALL (LESS THAN 30' FROM PROPERTY LINE) 11'-0 5/8" 16'-0 11/16" REVEGETATION TO MATCH EXISTING (SOD WHERE SOD WAS REMOVED, PERENIALS WHERE REMOVED) TYPICAL. TREE PROTECTION PER COA. SEE NOTES. NOTE THAT TREE PROTECTION IS REQUIRED WHEREVER ACTIVITY OCCURS EQ INSTALL NEW WATERLINE BETWEEN (2) LARGE COTTONWOODS 19'-0" REMOVE EXIST MECHANICAL UNITS TREE PROTECTION PER COA. SEE NOTES. EXIST STEPS TO REMAIN. RAISE STOOP AND TOP STEPS TO MEET CODE 5'-2 1/2" 5'-8 1/2"(SURVEYED) (SURVEYED) 5'-8 3/8" V.I.F. 5'-0" ISSUE FOR TH I S D R A W I N G I S T H E P R O P E R T Y O F G A L A M B O S A R C H I T E C T S I N C . A L L W R I T T E N A N D D R A W N I N F O R M A T I O N A P P E A R I N G H E R E I N S H A L L N O T B E D U P L I C A T E D , D I S C L O S E D O R O T H E R W I S E U S E D W I T H O U T T H E W R I T T E N C O N C E N T O F G A L A M B O S A R C H I T E C T S I N C C C O P Y R I G H T 2 0 1 9 G A L A M B O S ARCHITECTS, INC. 314 D AABC ASPEN, CO 81611 (970) 429-1286 DATE DRAWING DATE PROJECT 3/ 1 / 2 0 2 0 1 : 4 6 : 0 6 P M SA C K R E N O V A T I O N 21 0 S W E S T E N D S T R E E T A-001 PROPOSED SITE PLAN 03/01/2020 SACK RENOVATION NORTH SCALE 1" = 10'-0"1 PROPOSED SITE PLAN ARCHITECTURAL FLOOR ELEVATION 100'-0" = SITE ELEVATION 7940.3' Schematic Design 10.23.2018 RDS Approval 04.17.2019 Permit 05.09.2019 100% CDs 11.22.2019 Change Order 1 02.28.20 Area of limited mechanical and electrical work outside of building. Access is via alley and not through interior of structure. Access to mechanical room and crawl space is via direct exterior doors and not through any interior portions of areas being remodeled. Dumpster is outside of building, all trash disposal happens outside of the work areas. APPROVED CITY OF ASPEN ENGINEERING Refrigerator C C B B A A 4 4 3 3 2 2 1 1 A-201 A-2022 A-202 1 A-201 2 1 5 5 6 6 D D E E EXIST CRAWLSPACE R.O. BDRM 010 R.O. CLO 009 R.O. BATH 011 R.O. KITCHEN 012 R.O. LIVING 013 1 A-301 A2 A3 A4 013A 010A 011A 003A 013B 1 A-302 2 A-301 PROVIDE HOOKUPS FOR NEW W/D AND VENT WITH NEW 26 GA RIGID DUCT, CAULK ANNULAR SPACE, UTILIZE EXISTING DUCT ROUTE. RENOVATE EXISTING RESIDENT OCCUPIED UNIT: 1. INSTALL NEW FIRE SPRINKLER SYSTEM (THROUGHOUT LOWER LEVEL) 2. REPLACE ALL RECESSED LIGHTS WITH NEW LEDS. 3. REPLACE EXISTING HOT WATER BASEBOARD WITH ELECTRIC FLOOR HEAT THROUGHOUT UNIT. 4. PROVIDE NEW KITCHEN APPLIANCES AND CABINETS. 5. PROVIDE NEW BATH FIXTURES AND CABINETS. 6. INSTALL NEW DOORS AND HARDWARE. 7. INSTALL NEW PORCELAIN TILE FLOOR FINISH. 8. LEVEL 4 TEXTURE AND PAINT ON WALLS. 3'-9" 3 1/2" NEW ELEV 100 R.O. UNIT 4 UNIT 3 - LOWER GARAGE EXPANSION RENOVATE EXIST GARAGE/MECH/STORAGE: 1. INSTALL NEW FIRE SPRINKLER SYSTEM 2. REPLACE ALL LIGHTS WITH NEW LEDS. 3. INSTALL NEW DOORS AND HARDWARE. UP 4'-3 1/2"3 1/2" NEW STEEL COLUMNS 100A LOWER MUDRM 002 EXPANDED GARAGE 003 8 1 / 2 " 3' - 6 1 / 2 " 2 A-302 EXISTING RETAINING WALL R.O. STOR 008 008A 5'-0"3 1/2" UNIT 2 STOR 007 RECONFIGURED BACK STAIR 001 EXIST MECH 005 19 ' - 1 1 " EXIST STORAGE 004 3' - 8 " 3 1 / 2 " 4' - 1 0 1 / 2 " 2'-4 3/4" PROPERTY LINE SETBACK FROM PROPERTY LINEMORNINGSTAR MARKOVATOR HYDRAULIC ELEVATOR W/36X48 CAB. GC TO OBTAIN ELEVATOR PERMIT FROM NWCCOG 1-HR SEPARATION BETWEEN GARAGE AND RESIDENCE (CEILING AND WALLS) 6' - 0 " 3 1 / 2 " EXIST HOSE BIBREPLACE MECH NEW ELECT CT CABT, METER AND DIST PANEL T.O.F.F. EL. 91'-2" T.O.SLAB A-501 5 NEW 1-HR WALL/STC 52 A-501 8 A-402 1 NEW ELEVATOR EQUIPMENT - LOCATE IN CRAWLSPACE OR STORAGE ROOM PER CODE AND AS ACCEPTABLE TO MANUFACTURER EMERGENCY ESCAPE WDW SILL @ 41" AFF (VIF) 007A NEW ELECT PANEL 30" W X 36" DEEP CLEARSPACE 003C 5'-2 1/2" V.I.F. NEW ELECT PANEL (UNITS 1 & 2) 30" W X 36" DEEP CLEARSPACE EL. 91'-7" VERIFY FOUNDATION WALL/CRAWLSPACE UNDER APARTMENT ENTRY ABOVE AND/OR INSTALL NEW 1-HOUR DEMISING WALL 011B 004A 005A NEW 1-HR WALL A-501 4 NEW METAL PLANTER 6' - 5 1 / 2 " NEW CLOSET EXISTING FOUNDATION WALL 5' - 1 0 1 / 2 " 10 ' - 7 " 5' - 1 0 1 / 2 " EXIST F.D. A-800 1MECH UNIT 003B EL. 91'-2 1/2"002AT.O.F.F. 2" 5'-5 7/8" 5'-8 1/2" 14'-4 1/2" (SURVEYED) 8' - 1 0 " NEW FOUNDATION WALL V.I.F. (SURVEYED) TAO GRAY STONE FLOORING A1 NEW HOT AND COLD HOSE BIB 3' - 4 " 2' - 8 " 2' - 6 " 4" NEW PEGS/HOOKS AT BACK WALL PER OWNER SEE A-807 2'-6" 2'-6" ALIGN WALL W/WALL ABOVE 3'-2" V.I.F. 1.ALL NEW EXTERIOR WALLS TO BE 2x6 WOOD STUDS, TYPICAL U.N.O. INSULATE AS SHOWN ON DETAILS. 2.ALL INTERIOR WALLS TO BE 2x4 OR 2X6 WOOD STUDS, PLUMBING WALLS TO BE 2X6 TYPICAL U.N.O. INSULATE ALL INTERIOR WALLS WITH 3 1/2" SOUND BATT. SEE DETAILS FOR FIRE SEPARATION. 3.INSULATE ALL FLOORS ABOVE LIVING SPACE WITH 3 1/2" SOUND BATT. SEE DETAILS FOR FIRE SEPARATION. 4.DIMENSIONS ARE TO FACE OF CONCRETE FOUNDATION, FACE OF STUD WALL, AND CENTERLINE OR FACE OF COLUMN U.N.O. 5. DIMENSIONS ARE TO CENTERLINE OF DOOR OR WINDOW U.N.O. IF NO DIMENSION IS GIVEN, CENTER DOOR OR WINDOW IN WALL. PLAN NOTES WALLS - EXISTING WALLS - TO BE REMOVED WALLS - NEW CONSTRUCTION WALL LEGEND NORTH ISSUE FOR TH I S D R A W I N G I S T H E P R O P E R T Y O F G A L A M B O S A R C H I T E C T S I N C . A L L W R I T T E N A N D D R A W N I N F O R M A T I O N A P P E A R I N G H E R E I N S H A L L N O T B E D U P L I C A T E D , D I S C L O S E D O R O T H E R W I S E U S E D W I T H O U T T H E W R I T T E N C O N C E N T O F G A L A M B O S A R C H I T E C T S I N C C C O P Y R I G H T 2 0 1 9 G A L A M B O S ARCHITECTS, INC. 314 D AABC ASPEN, CO 81611 (970) 429-1286 DATE DRAWING DATE PROJECT 3/ 1 / 2 0 2 0 1 : 4 6 : 2 3 P M SA C K R E N O V A T I O N 21 0 S W E S T E N D S T R E E T A-101 PROPOSED LOWER LEVEL 03/01/2020 SACK RENOVATION SCALE 1/4" = 1'-0"1 PROPOSED LOWER LVL PLAN Schematic Design 10.23.2018 RDS Approval 04.17.2019 Permit 05.09.2019 Wdw Package 10.08.2019 100% CDs 11.22.2019 Change Order 1 02.28.20 Direct access to RO unit 4 via existing exterior door. All work on this area to be via this entrance. Continued slab demo and plumbing rough- in work to continue in this area with crews staggered. Existing exterior doors allow direct access to common mechanical and existing storage areas. MEP rough-in work to continue in these areas with all access to be via exterior doors. Unit 3 garage, lower level mud room, elevator and back stair have exterior access separate from other RO unit and mechanical/ storage areas noted to the left. Direct access will minimize unnecessary foot traffic between these areas. APPROVED CITY OF ASPEN ENGINEERING C C B B A A 4 4 3 3 2 2 1 1 A-201 A-2022 A-202 1 A-201 2 1 5 5 6 6 D D E E BATH 2 120 CLO 2 122 RECONFIGURED BDRM 2 118 BDRM 3 110 BATH 3 111 CLO 3 114 NEW MUDRM 103 RECONFIGURED LAUNDRY 108 RECONFIGURED M BATH 105M BDRM 104 NEW HALL 117 M TOILET 106 M SHWR 107 HALL 116 1 A-301 110B 111A 110A 118A 120A122A B3 DN G2 1 A-302 2 A-301 SHWR 2 121 TOILET 3 112 EXISTING UNIT 1 (MIN WORK) DN UP EXISTING ENTRY PORCH EXISTING WALK EXISTING EAST TERRACE EXISTING MASTER TERRACE ATTACH LOUVERS TO OPERABLE WINDOW TO ACT AS A SHUTTER. M CLO 109B G1 A-804 6 UNIT 2 LIVING UNIT 2 KITCHEN UNIT 2 BDRM APT ENTRY 130 NEW ELEV 100 EXISTING UNIT 2 (MIN WORK) UNIT 3 NEW STEEL BEAM TO ALLOW CLEARSPAN AT ENTRY RELOCATE EXIST ELECTRICAL PANEL 30" W X 36" DEEP CLEARSPACE 102A C1 UP D2 D3 D4 D5 D6 100B 6' - 1 0 " 5 1 / 2 " 12 ' - 5 " 3 1 / 2 " 5' - 6 " 2 A-302 RECONFIGURED BACK STAIR 101 D1 130A 131A DN EXISTING SITE STEPS TO REMAIN EXISTING SITE STEPS TO REMAIN UNIT 2 BATH 136A UNIT 2 DECK 133 REFINISH DECK NEW 42" HT RAILING ON EXISTING DECK NEW STEEL COLUMNS D8 D11 D12 B1 104B 133A 3' - 8 " N T S 3 1 / 2 " 136B UNIT 1- NEW DECK 140 A-401 1 RECONFIGURE TERRACE USING EXISTING PAVERS NEW STEPS - EXTEND OVER EXIST PLANTER NEW APARTMENT ENTRY DOOR TO REPLACE EXISTING INTERIOR DOOR RESTORE OPENING NEW APARTMENT ENTRY DOOR NEW ENTRY DOOR REMOVE DOOR AND INFILL WITH 1-HR WALL/STC 52 114A NEW STONE TILE OVER EXISTING ENTRY PORCH EL. 100'-0" T.O.F.F. EL. 100'-0" T.O.F.F. A-403 4 5'-3" M DRESSING 109A EQ EQ ALIGN NEW WALL WITH EXIST WALL EXIST HOSE BIB EXIST CRAWLSPACE ACCESS (18" X 24") NEW CRAWLSPACE ACCESS (18" X 24") EXISTING SEPARATION WALL EXISTING SEPARATION WALL TO BE BROUGHT UP TO CODE. SEE DETAIL 9/A-501 D13 108A 105D 120B F1 E1 A-201 3 GG2 EXISTING PLANTER HEATED TOWEL BAR 137A UNIT 1 BDRM RESTORE BDRM WALL AND DOOR EMERGENCY EGRESS WDW SILL @ 42" AFF (VIF) EMERGENCY EGRESS WDW SILL @ 42" AFF (VIF) DECK ABOVE DECK ABOVE FLOOR ABOVE NEW ROOF ABOVE NEW ROOF ABOVE A-402 2 NEW 42" HT RAILING ON NEW DECK FUTURE ELECT PANEL 30" W X 36" DEEP CLEARSPACE FUTURE ELECT PANEL 30" W X 36" DEEP CLEARSPACE A-501 8 REMOVE DOOR AND INFILL WITH 1-HR WALL/STC 52 A-501 8 A-501 8 INFILL WITH 1-HR WALL/STC 52 (SURVEYED) G3 CHASE, RE: MECH EXISTING TERRACE TO REMAIN REUSE EXISTING STONE PAVERS FLUSH WOOD THRESHOLD FLUSH WOOD THRESHOLD FLUSH WOOD THRESHOLD FLUSH STONE THRESHOLD FLUSH WOOD THRESHOLD NEW STEEL COLUMNS FLUSH STONE THRESHOLD FLUSH STONE THRESHOLD STD EQ EQ ABOVE EQ EQ 118B B4 B2 3 1 / 2 " 4' - 0 " 9" 5' - 9 1 / 2 " 3' - 0 " 3' - 1 0 " D7 D9 EQ EQ FLUSH STONE THRESHOLD AT NEW OPENING 2'-5" 9'-10" 2'-0" 2X6 FURRING REPLACE EXISTING HYDRONIC BASEBOARD WITH RADIANT FLOOR (TYP) RE: MECH 1' - 6 1 / 2 " 2'-1" 105B 105A 103A 3'-10 1/2" NEW ONE-HR WALL 1" 1' - 2 " 3" W/D W/D (VERIFY) A-501 4 105C V.I.F. NEW COFFEE BAR EL. 99'-10" A-804 1 A-803 1 A-802 1 A-801 1 104A 8' - 8 " 7'-5" 3' - 1 " FUR WALL FOR RETRACTABLE SCREEN 4 1/2" 5'-8 1/2" 5'-5 1/2" 5'-8 3/8" (SURVEYED) (SURVEYED) ALIGN WALLS COORDINATE INSET RUG W/OWNER 5'-4 1/2" RETRACTABLE SCREEN 5'-2 1/2" 1' - 6 " 1'-0" NEW STOOP MATCH F.F. F.F. MATCH UNIT FLOOR NEW STONE TILE AT STOOP AND 4 TOP STEPS EQ EQ 7'-1 1/2" 2' - 6 5 / 8 " 10'-0"6" 3'-7 1/2"3'-6" 3' - 0 " 4' - 1 " 4'-5"3'-0" 1' - 1 0 " 112A SHWR 3 113 S.T.D. 111B 117ALINEN 5'-6" 1'-6" 5'-3 1/2"3 1/2"3'-0" 2'-10"2'-10" ENTRY 102 TV CABINET RECONFIGURED UNIT 2 BATH GAS APPLIANCE 105E 1' - 9 1 / 2 " 3' - 3 " 1.ALL NEW EXTERIOR WALLS TO BE 2x6 WOOD STUDS, TYPICAL U.N.O. INSULATE AS SHOWN ON DETAILS. 2.ALL INTERIOR WALLS TO BE 2x4 OR 2X6 WOOD STUDS, PLUMBING WALLS TO BE 2X6 TYPICAL U.N.O. INSULATE ALL INTERIOR WALLS WITH 3 1/2" SOUND BATT. SEE DETAILS FOR FIRE SEPARATION. 3.INSULATE ALL FLOORS ABOVE LIVING SPACE WITH 3 1/2" SOUND BATT. SEE DETAILS FOR FIRE SEPARATION. 4.DIMENSIONS ARE TO FACE OF CONCRETE FOUNDATION, FACE OF STUD WALL, AND CENTERLINE OR FACE OF COLUMN U.N.O. 5. DIMENSIONS ARE TO CENTERLINE OF DOOR OR WINDOW U.N.O. IF NO DIMENSION IS GIVEN, CENTER DOOR OR WINDOW IN WALL. PLAN NOTES WALLS - EXISTING WALLS - TO BE REMOVED WALLS - NEW CONSTRUCTION WALL LEGEND NORTH ISSUE FOR TH I S D R A W I N G I S T H E P R O P E R T Y O F G A L A M B O S A R C H I T E C T S I N C . A L L W R I T T E N A N D D R A W N I N F O R M A T I O N A P P E A R I N G H E R E I N S H A L L N O T B E D U P L I C A T E D , D I S C L O S E D O R O T H E R W I S E U S E D W I T H O U T T H E W R I T T E N C O N C E N T O F G A L A M B O S A R C H I T E C T S I N C C C O P Y R I G H T 2 0 1 9 G A L A M B O S ARCHITECTS, INC. 314 D AABC ASPEN, CO 81611 (970) 429-1286 DATE DRAWING DATE PROJECT 3/ 1 / 2 0 2 0 1 : 4 6 : 3 2 P M SA C K R E N O V A T I O N 21 0 S W E S T E N D S T R E E T A-102 PROPOSED MAIN LEVEL 03/01/2020 SACK RENOVATION SCALE 1/4" = 1'-0"1 PROPOSED MAIN LVL PLAN SCOPE OF WORK AT MAIN HOUSE (MAIN LEVEL): 1. INSTALL NEW FIRE SPRINKLER SYSTEM THROUGHOUT BUILDING PER FIRE MARSHALL. 2.NEW MUDROOM OFF EXISTING ENTRY. 3.RECONFIGURE EXISTING BATHROOMS INCLUDING NEW PLUMBING FIXTURES AND FITTINGS, CABINETS, COUNTERTOP AND TILE/SLAB. 4.RECONFIGURE BEDROOM 2 TO CREATE NEW HALL. 5.NEW FLOORING INCLUDING WOOD AND STONE/TILE. 6.NEW 8' TALL INTERIOR DOORS AND HARDWARE. 7. NEW LIGHTING THROUGHOUT, SEE LIGHTING PLAN. 8.NEW HEATING AND COOLING, RE: MECH. 9.SKIM COAT EXIST WALLS (FLAT TEXTURE) AND RE-PAINT ENTIRE LEVEL. 10.NEW WINDOWS AND EXTERIOR DOORS (TYP MAIN LEVEL). ARCHITECTURAL FLOOR ELEVATION 100'-0" = SITE ELEVATION 7940.3' Schematic Design 10.23.2018 RDS Approval 04.17.2019 Permit 05.09.2019 Wdw Package 10.08.2019 100% CDs 11.22.2019 Change Order 1 02.28.20 Some extension of fire suppression piping will occur in this area. Only (1) trade will be permitted in this area at a time, and a maximum of (2) workers in this area will be enforced. Some extension of fire suppression piping will occur in this area. Only (1) trade will be permitted in this area at a time, and a maximum of (2) workers in this area will be enforced. Primary work area for the next 4-6 weeks (interior and limited adjacent exterior areas). Crews and subcontractors will be staggered to practice social distancing and all workers within this area will enter and exit via the most direct path (either the main entry way or exterior doors in bedrooms where possible. APPROVED CITY OF ASPEN ENGINEERING C C B B A A 4 4 3 3 2 1 1 A-201 A-2022 A-202 1 A-201 2 1 5 5 6 6 D D E E DN OPEN TO ENTRY BELOW DN 1 A-301 1 A-302 2 A-301 NEW STEEL COLUMN, RE: STRUCTURAL WRAP WITH STEEL TO CREATE CRISP EDGES OR USE SQUARE CORNERED COLUMN. PAINTED FINISH TO MATCH WINDOWS EXIST ROOF BELOW UNIT 3 - UPPER CC1 NEW ELEV 100 2 A-302 100C 212A 211A NEW PWD 211 RECONFIGURED BACK STAIR 201 BB3 BB11 HH1 HH2 203A 205A DW TRASH FREEZ 203B BREAKFAST 209 EXISTING LIVING 202 EXISTING SITTING 204 EXISTING DINING 205 EXISTING FAMILY 207 EXISTING OFFICE 212 EXISTING NORTH DECK 210 RECONFIGURED SOUTH DECK 203 NEW ROOF - 1 HOUR CONSTRUCTION 23'-0" 8' - 0 " RECONFIGURED EAST DECK 206 208A PROVIDE NEW APPLIANCES, PLUMBING, CABINETS AND COUTERTOPS NEW ROOF BELOW NEW GAS FIREPLACE AND SURROUND TO REPLACE EXISTING 6' - 0 " 5'-0 1/2" 19 ' - 8 " 1' - 7 3 / 4 " EQ 6'-7"EQ EXIST HOSE BIB DD4 EE1 EE3 GG1 A-201 3 BB9 EL. 110'-1" T.O.F.F. (VERIFY) EXISTING ROOF OVERHANG - UPGRADE TO 1-HOUR CONSTRUCTION NEW ROOF OVERHANG 1-HR CONSTRUCTION NEW 42" HT GUARDRAIL (TYP AT DECKS) NEW 42" HT GUARDRAIL (TYP AT DECKS) DW WDW ABOVE DD1 DD5 NEW FINISHES ON EXIST FIREPLACE 3' - 0 " O. H . NEW ROOF EQ EQ DD3 NEW ROOF DD2 EE5 BB12 BB10 BB4 BB2 OVENS FLUSH WOOD THRESHOLD EQ EQ EQ EQ JJ4 A-403 11 REPLACE EXISTING WOOD DECKING WITH NEW TILE SNOWMELTED DECKING NEW 1-HR WALL RENOVATED KITCHEN 208 A-401 1 NEW FLOOR GRILLE RE: MECH EXISTING ACCESS TO ATTIC NEW ACCESS TO ATTIC REFR NEW WOOD FLOOR FLUSH WOOD THRESHOLD RE: A-805 & Arclinea drawings RE: A-806 A-803 12 8' - 8 " EQ EQ WINE FF4 FF7 FF5FF3 9" A-601 10 9" FF6FF2 FF1 3'-3"3'-1 1/2"3'-3" 3' - 3 " EE2 EE4 EE6 BB1 EQ EQ GG3 EQ EQ EQ EQ 11'-10 1/4" PROVIDE GAS TO BBQ - VERIFY LOCATION 1.ALL NEW EXTERIOR WALLS TO BE 2x6 WOOD STUDS, TYPICAL U.N.O. INSULATE AS SHOWN ON DETAILS. 2.ALL INTERIOR WALLS TO BE 2x4 OR 2X6 WOOD STUDS, PLUMBING WALLS TO BE 2X6 TYPICAL U.N.O. INSULATE ALL INTERIOR WALLS WITH 3 1/2" SOUND BATT. SEE DETAILS FOR FIRE SEPARATION. 3.INSULATE ALL FLOORS ABOVE LIVING SPACE WITH 3 1/2" SOUND BATT. SEE DETAILS FOR FIRE SEPARATION. 4.DIMENSIONS ARE TO FACE OF CONCRETE FOUNDATION, FACE OF STUD WALL, AND CENTERLINE OR FACE OF COLUMN U.N.O. 5. DIMENSIONS ARE TO CENTERLINE OF DOOR OR WINDOW U.N.O. IF NO DIMENSION IS GIVEN, CENTER DOOR OR WINDOW IN WALL. PLAN NOTES WALLS - EXISTING WALLS - TO BE REMOVED WALLS - NEW CONSTRUCTION WALL LEGEND NORTH ISSUE FOR TH I S D R A W I N G I S T H E P R O P E R T Y O F G A L A M B O S A R C H I T E C T S I N C . A L L W R I T T E N A N D D R A W N I N F O R M A T I O N A P P E A R I N G H E R E I N S H A L L N O T B E D U P L I C A T E D , D I S C L O S E D O R O T H E R W I S E U S E D W I T H O U T T H E W R I T T E N C O N C E N T O F G A L A M B O S A R C H I T E C T S I N C C C O P Y R I G H T 2 0 1 9 G A L A M B O S ARCHITECTS, INC. 314 D AABC ASPEN, CO 81611 (970) 429-1286 DATE DRAWING DATE PROJECT 3/ 1 / 2 0 2 0 1 : 4 6 : 4 0 P M SA C K R E N O V A T I O N 21 0 S W E S T E N D S T R E E T A-103 PROPOSED UPPER LEVEL 03/01/2020 SACK RENOVATION SCALE 1/4" = 1'-0"1 PROPOSED UPPER LVL PLAN Schematic Design 10.23.2018 RDS Approval 04.17.2019 Permit 05.09.2019 Wdw Package 10.08.2019 100% CDs 11.22.2019 Change Order 1 02.28.20 Primary work area for the next 4-6 weeks (interior and limited adjacent exterior areas). Crews and subcontractors will be staggered to practice social distancing and all workers within this area will enter and exit via the most direct path (either the main entry way or exterior doors in bedrooms where possible. APPROVED CITY OF ASPEN ENGINEERING