UL Listings
C-AJ-1291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
C-AJ-1346 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
C-AJ-2109 (US Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
F-A-2075 (US Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
F-A-2093 (US Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
W-L-1410 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
W-L-2128 (US Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
W-L-3065 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
W-L-5028 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
W-L-5029 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
CP 606 Firestop acrylic sealant
Product Data Sheet for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
UL Certificate of Compliance for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Safety Data Sheet (SDS) for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
LEED Information for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
CP 643 N firestop collars
Product Data Sheet for CP 643N Firestop Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
UL Certificate of Compliance for CP 643N Firestop Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Safety Data Sheet (SDS) for CP 643N, CP 644 Firestop Collar and CP 648-S, CP 648-E
Firestop Wrap Strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
LEED Information for CP 643N and CP 644 Firestop Collars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
CP 644 Firestop collars US
Product Data Sheet for CP 644 Firestop Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
UL Certificate of Compliance for CP 644 Firestop Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Safety Data Sheet (SDS) for CP 643N, CP 644 Firestop Collar and CP 648-S, CP 648-E
Firestop Wrap Strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
LEED Information for CP 643N and CP 644 Firestop Collars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
FS-ONE MAX Firestop intumescent sealant
Product Data Sheet for FS-ONE MAX Intumescent Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . 41
UL Certificate of Compliance for FS-ONE MAX Intumescent Firestop Sealant . . . . . . . . . . . . . . . . . . 42
Safety Data Sheet (SDS) for FS-ONE MAX Intumescent Firestop Sealant . . . . . . . . . . . . . . . . . . . . 43
LEED Information for FS-ONE MAX Intumescent Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Mineral wool
Product Data Sheet for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
UL Certificate of Compliance for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
LEED Information for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
05/21/2019
05/21/2019
System No. C-AJ-1346
SECTION A-A
CA
J
1
3
4
6
)ORRURU:DOO$VVHPEO\²0LQLQPPWKLFNUHLQIRUFHGOLJKWZHLJKWRUQRUPDOZHLJKWSFIRUNJPFRQFUHWH:DOO
may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 3 in. (76 mm).
See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers.
7KURXJK3HQHWUDQW²0D[RQHIOH[LEOHPHWDOSLSHRUFRQGXLWLQVWDOOHGFRQFHQWULFDOO\RUHFFHQWULFDOO\ZLWKLQRSHQLQJ7KHDQQXODUVSDFHEHWZHHQ
penetrant and periphery of opening shall be min of 1/2 in. (13 mm) to max 1-1/4 in. (32 mm). Penetrant to be rigidly supported on both sides of
floor or wall assembly. The following types and sizes of penetrants may be used:
$)OH[LEOH6WHHO&RQGXLW²1RPLQPPGLDPRUVPDOOHUIOH[LEOHVWHHOFRQGXLW
See Flexible Metal Conduit (DXUZ) category in the Electrical Construction Material Directory for names of manufacturers.
%7KURXJK3HQHWUDWLQJ3URGXFW
²)OH[LEOH0HWDO3LSLQJ²7KHIROORZLQJW\SHVRIVWHHOIOH[LEOHPHWDOJDVSLSLQJPD\EHXVHG
1. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides
of floor or wall assembly.
OMEGA FLEX INC
2. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides
of floor or wall assembly.
GASTITE, DIV OF TITEFLEX
3. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides
of floor or wall assembly.
WARD MFG L L C
)LUHVWRS6\VWHP²7KHILUHVWRSV\VWHPVKDOOFRQVLVWRIWKHIROORZLQJ
$3DFNLQJ0DWHULDO²0LQLQPPWKLFNQHVVRIPLQSFINJPPLQHUDOZRROEDWWLQVXODWLRQILUPO\SDFNHGLQWRWKHRSHQLQJDVD
permanent form. Packing material to be recessed from top surface of floor or both surfaces of wall to accommodate the required thickness of
fill material.
%)LOO9RLGRU&DYLW\0DWHULDOV
²6HDODQW²0LQLQPPWKLFNQHVVRIVHDODQWDSSOLHGZLWKLQDQQXODUVSDFHIOXVKZLWKWRSVXUIDFHRI
floor or both surfaces of wall.
+,/7,&216758&7,21&+(0,&$/6',92)+,/7,,1&²)621(6HDODQWRU)621(0$;,QWXPHVFHQW6HDODQW
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada),
respectively.
+Bearing the UL Listing Mark
A
Reproduced by HILTI, Inc. Courtesy of
Underwriters Laboratories, Inc.
January 08, 2015
A
1A
1B
3B
3A2
3B
2
C
CL A S S IFI
E
D
Classified by
Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115
US ANSI/ UL1479 (ASTM E814)CAN/ULC S115
F Rating - 2 Hr F Rating - 2 Hr
T Rating - 0 Hr FT Rating - 0 Hr
FH Rating - 2 Hr
FTH Rating - 0 Hr
05/21/2019
Hilti Firestop Systems
System No. C-AJ-2109
SECTION A-A
CA
J
2
1
0
9
Page: 1 of 2
1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall
may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 12 in. (305 mm).
See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufactures.
2. Steel Sleeve — (Optional) — Nom 12 in. (305 mm) diam (or smaller) Schedule 40 (or heavier) steel pipe cast or grouted into floor or wall
assembly, flush with floor or wall surfaces a max of 3 in. (76 mm) above the floor. If the steel sleeve extends above the floor, the T Rating of the
firestop system is 0 Hr and a min 1/2 in. (13 mm) annular space is required between the through penetrant (Item 3) and the periphery of the
opening. The W Rating does not apply when the steel sleeve is used.
3. Through Penetrants — One nonmetallic pipe to be installed either concentrically or eccentrically within the firestop system. For max 6 in. (152
mm) diam pipes, the annular space between the pipe and the periphery of opening shall be min 0 in. (0 mm, point contact) to max 1/2 in. (13 mm).
For nom 8 in. (203 mm) and 10 in. (254 mm) diam pipes, the annular space between the pipe and the periphery of opening shall be min 0 in. (0
mm, point contact) to max 1-1/4 in. (32 mm). If the steel sleeve extends above the floor (Item 2), a min 1/2 in. (13 mm) annular space is required
between the through penetrant (Item 3) and the periphery of the opening. Pipe to be rigidly supported on both sides of floor or wall assembly. For
systems with a W Rating, the max annular space is 1/2 in. (13 mm). The T Ratings are dependent on the size and/or type of pipe as shown in the
table below. The following types and sizes of nonmetallic pipes may be used:
A. Polyvinyl Chloride (PVC) Pipe — Nom 10 in. (254 mm) diam (or smaller) Schedule 40 solid core or cellular core PVC pipe for use in closed
(process or supply ) or vented (drain, waste or vent) piping systems. For systems with a W Rating, the nom diam of pipe shall not exceed 6 in.
(152 mm).
B. Chlorinated Polyvinyl Chloride (CPVC) Pipe — Nom 10 in. (254 mm) diam (or smaller) SDR13.5 CPVC pipe for use in closed (process or
supply) piping systems. For systems with a W Rating, the nom diam of pipe shall not exceed 6 in. (152 mm).
C. Acrylonitrile Butadiene Styrene (ABS) Pipe — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 solid-core or cellular core ABS pipe for use
in closed (process or supply) or vented (drain, waste or vent) piping system.
D. Flame Retardant Polypropylene (FRPP) Pipe — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 FRPP pipe for use in closed (process or
supply) or vented (drain, waste or vent) piping systems.
Reproduced by HILTI, Inc. Courtesy of
Underwriters Laboratories, Inc.
July 31, 2018
)5DWLQJV³DQG+U6HH,WHP
75DWLQJV³DQG+U6HH,WHPVDQG
W Rating - Class 1 (See Items 2, 3 and 4)
/5DWLQJDW$PELHQW³/HVV7KDQ&)0VTIW6HH,WHP
/5DWLQJDW)³/HVV7KDQ&)0VTIW6HH,WHP
A A
3 2
5 4 5 4
2 1
3
CL A S S IFI
E
D
Classified by
Underwriters Laboratories, Inc.
to UL 1479
05/21/2019
Page: 2 of 2
+ Indicates solid core ABS only.
++ Indicates cellular core ABS only.
4. Fill, Void or Cavity Material* — Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with top or bottom surface
of floor or both surfaces of wall. Sealant is optional for pipes having a max diam of 6 in. (152 mm) in unsleeved openings. For systems with W
Rating and/or L Rating, min 1/2 in. (13 mm) thickness of CP 601S, CFS-S SIL GG, CFS-S SIL SL (floors only) Sealant shall be applied within the
annulus, flush with top or bottom surface of floor.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE MAX Intumescent Sealant, CP 601S Sealant, CFS-S SIL GG, CFS-S SIL
SL (floors only) Sealant
4A. Packing Material — (Not Shown) — Min 1/2 in. (13 mm) thickness of 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into annular
space and recessed from the top surface of floor to accommodate the required thickness of fill material. Required only when CP 604 Sealant is
used.
5. Firestop Device* — Firestop Collar — Firestop collar shall be installed in accordance with the accompanying installation instructions. Collar to be
installed and latched around the pipe and secured to underside of floor or both sides of wall using the anchor hooks provided with the collar.
Minimum two anchor hooks for nom 1-1/2 and 2 in. (38 and 51 mm) diam pipes. Minimum three anchor hooks required for nom 3 and 4 in. (76 and
102 mm) diam pipes. Minimum four anchor hooks required for nom 6 in. (152 mm) diam pipes. Minimum ten anchor hooks required for nom 8 in
(203 mm) diam pipes. Minimum twelve anchor hooks required for nom 10 in. (254 mm) diam pipes. The anchor hooks are to be secured with min
1/4 in. (6 mm) diam by min 1-1/4 in. (32 mm) long steel expansion bolts or min 0.145 in. (3.7 mm) diam by 1-1/4 in. (32 mm) long powder actuated
fasteners utilizing a 1-7/16 in. (37 mm) diam by 1/16 in. (1.6 mm) thick steel washer. As alternates to the anchors specified above, Hilti 1/4 in. (6
mm) diam by 1-1/4 in. (32 mm) long KWIK-CON II+ concrete screw anchor, Hilti 1/4 in. (6 mm) diam by 1-3/4 in. (45 mm) long KWIK-BOLT 3 steel
expansion anchor or Hilti X-DNI 27 P8 S15 powder actuated floor pin with integral nom 9/16 in. (15 mm) diam washer may be used.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 643N 50/1.5", CP 643N 63/2", CP 643N 90/3", CP 643N 110/4", CP 643 160/6",
CP 644-200/8" US or CP 644-250/10" US Firestop Collar
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada),
respectively.
Hilti Firestop Systems
CA
J
2
1
0
9
Pipe
Type
Nom Pipe
Diam, In. (mm)
F Rating
Hr
PVC, CPVC Greater than 6 (152)2
PVC, CPVC, ABS, FRPP 6 (152) or smaller 3
Pipe
Type
Nom Pipe
Diam, In. (mm)
T Rating
Hr
PVC, CPVC, ABS, FRPP 1-1/2, 2, 3 (38, 51, 76)2
PVC, CPVC, ABS, FRPP 4 (102)3
PVC, CPVC, ABS+, FRPP 6 (152)3
PVC, CPVC Greater than 6 (152)0
ABS++6 (152)0
Reproduced by HILTI, Inc. Courtesy of
Underwriters Laboratories, Inc.
July 31, 2018
System No. C-AJ-2109
05/21/2019
05/21/2019
05/21/2019
05/21/2019
05/21/2019
System No. W-L-3065
SECTION A-A
WL
3
0
6
5
Page: 1 of 2
1. Wall Assembly — The 1 or 2 fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in
the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following
construction features:
A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm)
lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC.
B. Gypsum Board* — Nom 5/8 in. (16 mm) thick gypsum board, with square or tapered edges. The gypsum board type, thickness, number of
layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design in the UL Fire Resistance Directory.
Max diam of opening is 5-1/2 in. (138 mm) when sleeve (Item 2) is employed. Max diam of opening is 4 in. (102 mm) when sleeve (Item 2) is
not employed.
The F, FH Ratings of the firestop system are equal to the fire rating of the wall assembly.
2. Metallic Sleeve — (Optional) - Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT) or Schedule 5 (or heavier) steel pipe or
min 0.016 in. thick (0.41 mm, No. 28 ga) galv steel sleeve installed flush with wall surfaces. The annular space between steel sleeve and
periphery of opening shall be min 0 in. (0 mm, point contact) to max 1 in. (25mm). When Schedule 5 steel pipe or EMT is used, sleeve may extend
up to 18 in. (457 mm) beyond the wall surfaces. As an option when Schedule 5 steel pipe or EMT is used, sleeve may extend continuously beyond
one wall surface. When cable bundle penetrates wall assembly at an angle of 45 degrees, no metallic sleeve is used.
Reproduced by HILTI, Inc. Courtesy of
Underwriters Laboratories, Inc.
October 14, 2015
A
A
2
3
4
1B
Hilti Firestop Systems
2 1A
C
CL A S S IFI
E
D
Classified by
Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115
US
ANSI/UL1479 (ASTM E814)CAN/ULC S115
F Rating — 1 and 2 Hr (See Item 1)F Rating — 1 and 2 Hr (See Item 1)
T Rating — 0 and 3/4 Hr (See item 3)FT Rating — 0 and 3/4 Hr (See item 3)
L Rating At Ambient — 15 CFM/sq ft FH Rating — 1 and 2 Hr (See Item 1)
L Rating At 400 F — 8 CFM/sq ft FTH Rating — 0 and 3/4 Hr (See item 3)
L Rating At Ambient — 15 CFM/sq ft
L Rating At 400 F — 8 CFM/sq ft
05/21/2019
Page: 2 of 2
3. Cables — Aggregate cross-sectional area of cable in opening to be max 45 percent of the cross-sectional area of the opening. The annular
space between the cable bundle and the periphery of the opening to be min 0 in. (point contact) to max 1 in. (25 mm). When sleeve is
continuous on one side of wall (see Item 2), the cable fill may be 0 to 45% and the max annular space is not limited. Cables to be rigidly
supported on both sides of the wall assembly. Any combination of the following types and sizes of copper conductor cables may be used:
A. Max 7/C No. 12 AWG with polyvinyl chloride (PVC) insulation and jacket.
B. Max 25 pair No. 24 AWG telephone cable with PVC insulation and jacket.
B1. Max 4 pr No. 22 AWG Cat 5 or Cat 6 computer cables.
C. Type RG/U coaxial cable with polyethylene (PE) insulation and PVC jacket having a max outside diameter of ½ in. (13 mm).
C1. Max RG 6/U coaxial cable with fluorinated ethylene insulation and jacketing.
D. Multiple fiber optical communication cable jacketed with PVC and having a max OD of 5/8 in. (16 mm).
E. Through Penetrating Products*— Max three copper conductor No. 8 AWG .Metal-Clad Cable+.
AFC CABLE SYSTEMS INC
F. Max 3/C (with ground)(or smaller) No. 8 AWG copper conductor cable with PVC insulation and jacketing.
G. Max 3/4 in. (19 mm) diam copper ground cable with or without a PVC jacket.
H. Fire Resistive Cables* - Max 1-1/4 in. (32 mm) diam single conductor or multi conductor Type MI cable. A min 1/8 in. (3 mm) separation
shall be maintained between MI cables and any other types of cable.
I. Max 4/C with ground 300 kcmil (or smaller) aluminum SER cable with PVC insulation and jacket.
J. Through Penetrating Product* - Any cables, Metal-Clad Cable+ or Armored Cable+ currently Classified under the Through Penetrating
Products category.
K. Maximum 3/C No. 8 AWG metal-clad cable.
L. Maximum 5/8 diam fiber-optic cable with PVC jacket.
For cable bundle penetrating the wall assembly at an angle of 45 degrees, the T, FT, FTH Ratings are 0 hr and 3/4 hr for 1 and 2 hr wall
assemblies, respectively.
See Through Penetrating Product (XHLY) category in the Fire Resistance Directory for names of manufacturers.
4. Fill, Void or Cavity Material*— Sealant or Putty — Fill material applied within the annulus, flush with each end of the steel sleeve or wall
surface. Fill material installed symmetrically on both sides of the wall. A min 5/8 in. (16 mm) thickness of sealant is required for the 1 or 2 hr F
Rating . An additional 1/2 in. (13 mm) diam bead of fill material shall be applied at the interface of sleeve with gypsum board.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP601S, CP606, FS-One Sealants or FS-ONE MAX Intumescent Sealantor or
CP618 Putty
5. Packing Material — (Optional, Not Shown) — Mineral wool forming material may be used as a backer for the fill material (Item 4). When used,
it shall be firmly packed into annular space within the sleeve as a permanent form and recessed from end of sleeve to accommodate the
required thickness of fill material.
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada),
respectively.
WL
3
0
6
5
Hilti Firestop Systems
System No. W-L-3065
Reproduced by HILTI, Inc. Courtesy of
Underwriters Laboratories, Inc.
October 14, 2015 05/21/2019
05/21/2019
05/21/2019
System No. W-L-5029
SECTION A-A
WL
5
0
2
9
Page: 1 of 2
A
Reproduced by HILTI, Inc. Courtesy of
Underwriters Laboratories, Inc.
July 17, 2015
A
2
4 3
2
3
4
Hilti Firestop Systems
1
C
CL A S S IFI
E
D
Classified by
Underwriters Laboratories, Inc.
to UL 1479 and CAN/ULC-S115
US
ANSI/UL1479 (ASTM E814)CAN/ULC S115
F Ratings — 1, 2 and 3 Hr (See Items 1, 3 and 4)F Ratings — 1, 2 and 3 Hr (See Items 1, 3 and 4)
T Ratings — 0, 1/2, 1 and 1-1/4 Hr (See Item 3)FT Ratings — 0, 1/2, 1 and 1-1/4 Hr (See Item 3)
L Rating At Ambient — 4 CFM/Sq Ft FH Ratings — 1, 2 and 3 Hr (See Items 1, 2 and 4)
L Rating At 400 F — Less Than 1 CFM/Sq Ft FTH Ratings — 0, 1/2, 1 and 1-1/4 Hr (See Item 3)
L Rating At Ambient — 4 CFM/Sq Ft
L Rating At 400 F — Less Than 1 CFM/Sq Ft
1. Wall Assembly — The 1, 2 or 3 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in
the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following
construction features:
A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm)
lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide for 1 and 2 hr F and FH rating and 3-1/2 in. (89 mm) wide for
3 hr F and FH rating and spaced max 24 in. (610 mm) OC.
B. Gypsum Board* — Min 5/8 in. (16 mm) thick with square or tapered edges. The gypsum board type, thickness, number of layers, fastener
type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam of opening is 18-5/8 in. (473 mm).
The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed.
2. Through Penetrants — One metallic pipe or tubing to be installed within the firestop system. Pipe or tubing to be rigidly supported on both sides
of wall assembly. The following types and sizes of metallic pipes or tubing may be used:
A. Steel Pipe — Nom 12 in. (305 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe.
B. Iron Pipe — Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe.
C. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. When the hourly F or FH Rating of the firestop
system is 3 hr, the nom diam of copper tube shall not exceed 4 in. (102 mm).
D. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. When the hourly F or FH Rating of the firestop
system is 3 hr, the nom diam of copper pipe shall not exceed 4 in. (102 mm).
05/21/2019
Page: 2 of 2
WL
5
0
2
9
Reproduced by HILTI, Inc. Courtesy of
Underwriters Laboratories, Inc.
July 17, 2015Hilti Firestop Systems
3. Pipe Covering* — Nom 1, 1-1/2 or 2 in. (25, 38 or 51 mm) thick hollow cylindrical heavy density (min 3.5 pcf or 56 kg/m3) glass fiber units
jacketed on the outside with an all service jacket. Longitudinal joints sealed with metal fasteners or factory-applied self-sealing lap tape.
Transverse joints secured with metal fasteners or with butt tape supplied with the product. For 1 and 2 hr F and FH Ratings, the annular space
between insulated penetrant and periphery of opening shall be min 0 in. (point contact) to max 1-7/8 in. (48 mm). For 3 hr F and FH Ratings, the
annular space shall be min 0 in. (point contact) to max 1-1/4 in. (32 mm).
See Pipe and Equipment Covering — Materials (BRGU) category in the Building Material Directory for the names of manufacturers. Any pipe
covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a
Smoke Developed Index of 50 or less may be used.
The hourly T, FT, FTH Ratings of the firestop system are 1/2 hr for 1 hr rated walls and 1 hr for 2 hr rated walls. For 3 hr rated walls, the hourly T,
FT and FTH Ratings when steel and iron pipes are used are 1 hr. For 3 hr rated walls, the hourly T, FT and FTH Ratings when copper penetrants
are used are 1-1/4 hr for 2 in. (51 mm) thick pipe covering and 0 hr for pipe covering thickness less than 2 in. (51 mm).
3A. Pipe Covering* — (Not Shown) — As an alternate to Item 3, max 2 in. (51 mm) thick cylindrical calcium silicate (min 14 pcf) units sized to the
outside diam of the pipe or tube may be used. Pipe insulation secured with stainless steel bands or min 18 AWG stainless steel wire spaced max
12 in. (305 mm) OC. When the alternate pipe covering is used, the T and FT Rating shall be as specified in item 3 above.
See Pipe and Equipment Covering — Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe
covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a
Smoke Developed Index of 50 or less may be used.
4. Fill, Void or Cavity Material* — Sealant — For 1 and 2 hr F and FH Rating, min 5/8 in. (16 mm) thickness of fill material applied within the
annulus, flush with both surfaces of wall. For 3 hr F and FH Rating, min 1 in. (25 mm) thickness of fill material applied within the annulus, flush
with both surfaces of wall. At the point contact location between pipe covering and gypsum board, a min 1/2 in. (13 mm) diam bead of fill material
shall be applied at the pipe covering/gypsum board interface on both surfaces of wall.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant
* Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada),
respectively.
System No. W-L-5029
05/21/2019
Product Information
Hilti. Outperform. Outlast.
Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide
In
t
r
o
d
u
c
t
i
o
n
Ap
p
l
i
c
a
t
i
o
n
s
a
n
d
P
r
o
d
u
c
t
s
Se
l
e
c
t
o
r
G
u
i
d
e
Th
r
o
u
g
h
-
P
e
n
e
t
r
a
t
i
o
n
Jo
i
n
t
Re
f
e
r
e
n
c
e
D
a
t
a
Flexible Firestop Sealant (CP 606)
Product description
■An acrylic based firestop sealant that provides movement
capability in fire rated joints and seals through-penetrations
applications
Product features
■Silicone free
■Halogen, asbestos and solvent free
■Paintable
■Tested up to 33% movement with 500 cycles in accordance to UL
2079 and ASTM 1966
■Smoke and fume resistant
■Easy clean up with water
■Single component systems available
■Meets LEED™ requirements for indoor environmental quality credit
4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints
and Coatings
Areas of application
■Sealing construction/expansion joints
■Top-of-wall joints
■Metal pipes
■Cable bundles
■HVAC penetrations
For use with
■Various base materials such as masonry, concrete, gypsum, etc.
■Wall and floor assemblies rated up to 3 hours
Examples
■Where a gypsum wall assembly meets the underside of a metal or
concrete deck
■Sealing expansion joints to impede the passage of fire, smoke and
toxic fumes
■Sealing around HVAC penetrations through fire-rated assemblies FM
$33529('
)RU3HQHWUDWLRQ)LUH6WRSV
&RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH
R
FILL, VOID OR CAVITY MATERIALS
CLASSIFIED BY
UNDERWRITERS LABORATORIES, INC.
FOR USE IN TROUGH-PENETRATION
FIRESTOP SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
66Y7
Notice
• Before handling, read Material Safety Data Sheet and
product label for safe usage and health information.
• Instructions below are general guidelines — always
refer to the applicable drawing in the UL Fire
Resistance Directory or Hilti Firestop Systems Guide
for complete installation information
• The use of backing material is recommended to
control the sealant depth and help ensure assembly
seal is complete
Opening
1. Clean the opening. Surfaces to which CP 606 will
be applied should be cleaned of loose debris, dirt,
oil, wax and grease. The surface should be moisture
and frost free.
Application of firestop
2. Insert fill of mineral wool or backer (as required).
3. Apply firestop over backer.
4. Smooth firestop sealant with a trowel before the skin
forms. Once cured, CP 606 can only be removed
mechanically.
5. For maintenance reasons, a penetration seal can be
permanently marked with an identification plate and
fastened in a visible position next to the seal.
Not for use
• On areas immersed in water
Storage
• Store only in the original packaging in a location
protected from moisture at a temperature of 40°F to
77°F (5°C to 25°C)
• Observe expiration date on package
Installation instructions for CP 606
1. Clean opening 2. Insert backing
material compressed
per UL System
3. Apply CP 606 4. Smooth CP 606 5. Fasten identification
plate (if required)
1. Clean opening 2. Insert backing
material
3. Apply CP 606 4. Smooth CP 606 5. Fasten identification
plate (if required)
FirestopSystem
FirestopSystemFirestopSystem
JO
I
N
T
DU
C
T
FILL, VOID OR CAVITY MATERIAL
FOR USE IN THROUGH-PENETRATION
FIRESTOP SYSTEMS AND
JOINT SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
66Y7
Technical Data* CP 606
Chemical basis Acrylic based firestop sealant
Color Available in red, white and gray
Application temperature 40°F to 104°F (5°C to 40°C)
Skin-forming time Approx. 15 min
Curing time Approx. 3 mm / 3 days
Average volume shrinkage
(ASTM C1241)
22.2%
Movement capability Approx. 10%
Temperature resistance –22°F to 176°F (–30°C to 80°C)
Surface burning characteristics
(ASTM E 84-96)
Flame Spread: 10
Smoke Development: 0
Sound transmission classification
(ASTM E 90-99)
56
(Relates to specific construction)
Tested in accordance with
• UL 2079 • ASTM E 814 • ASTM E 1966
• ASTM E 84 • UL 1479 • ASTM G21
*At 73°F (23°C) and 50% relative humidity
05/21/2019
CERTIFICATE OF COMPLIANCE
Certificate Number 20160930-R13240
Report Reference R13240
Issue Date 2016-September-30
Bruce Mahrenholz, Director North American Certification Program
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 1
Issued to: Hilti Construction Chemicals, Div of Hilti Inc.
5400 S 122nd East Ave
Tulsa, OK 74146
This is to certify that
representative samples of
Fill, Void or Cavity Materials
Fill, Void or Cavity Materials Certified for Canada
CP 606 Sealant for use in Through-Penetration Firestop,
Joint in wall and partition Systems as currently decribed in
the UL Fire Resistance Directory and in the Products
Certified for Canada Directory.
Have been investigated by UL in accordance with the
Standard(s) indicated on this Certificate.
Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Through-Penetration
Firestops,"
ANSI/UL 2079, "Tests for Fire Resistance of Building Joint
Systems,"
CAN/ULC-S115, "Standard Method of Fire Tests of Firestop
Systems."
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information
Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.
Look for the UL Certification Mark on the product.
05/21/2019
Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
Date of issue: 01/07/2016 Revision date: 01/07/2016 Supersedes: 01/07/2016 Version: 4.2
07/01/2016 EN (English) 1/7
SECTION 1: Identification
1.1. Identification
Product form Mixture
Name Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
Product code BU Chemicals
Chemical structure
1.2. Relevant identified uses of the substance or mixture and uses advised against
No additional information available
1.3. Details of the supplier of the safety data sheet
Hilti, Inc.
Legacy Tower, Suite 1000
75024 Plano - USA
T +1 9724035800
1-800-879-8000 toll free - F +1 918 254 0522
Supplier
Hilti, Inc.
Legacy Tower, Suite 1000
75024 Plano - USA
T +1 9724035800
1-800-879-8000 toll free - F +1 918 254 0522
Department issuing data specification sheet
Hilti AG
Feldkircherstraße 100
9494 Schaan - Liechtenstein
T +423 234 2111
chemicals.hse@hilti.com
1.4. Emergency telephone number
Emergency number Chem-Trec
Tel.: 1 800 424 9300 (USA, PR, Virgin Islands, Canada)
Tel.: 703 527 3887 (Other countries)
+1 918 8723000
1-800-879-8000 toll free
SECTION 2: Hazards identification
2.1. Classification of the substance or mixture
GHS-US classification
Not classified
2.2. Label elements
GHS-US labelling
No labelling applicable
2.3. Other hazards
No additional information available
2.4. Unknown acute toxicity (GHS US)
Not applicable
05/21/2019
Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
07/01/2016 EN (English) 2/7
SECTION 3: Composition/information on ingredients
3.1. Substance
Not applicable
3.2. Mixture
Full text of H-statements: see section 16
SECTION 4: First aid measures
4.1. Description of first aid measures
First-aid measures after inhalation Get medical advice/attention if you feel unwell.
First-aid measures after skin contact Wash skin with plenty of water. If skin irritation occurs: Get medical advice/attention.
First-aid measures after eye contact Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to
do. Continue rinsing. If eye irritation persists: Get medical advice/attention.
First-aid measures after ingestion Get medical advice/attention if you feel unwell.
4.2. Most important symptoms and effects, both acute and delayed
No additional information available
4.3. Indication of any immediate medical attention and special treatment needed
No additional information available
SECTION 5: Firefighting measures
5.1. Extinguishing media
Suitable extinguishing media Water spray. Dry powder. Foam. Carbon dioxide.
5.2. Special hazards arising from the substance or mixture
Reactivity The product is non-reactive under normal conditions of use, storage and transport.
5.3. Advice for firefighters
Protection during firefighting Self-contained breathing apparatus. Complete protective clothing.
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
6.1.1. For non-emergency personnel
No additional information available
6.1.2. For emergency responders
Protective equipment For further information refer to section 8: "Exposure controls/personal protection".
6.2. Environmental precautions
No additional information available
6.3. Methods and material for containment and cleaning up
Methods for cleaning up Recover mechanically the product.
6.4. Reference to other sections
For further information refer to section 13.
05/21/2019
Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
07/01/2016 EN (English) 3/7
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Precautions for safe handl ing Wear personal protective equipment.
Hygiene measures Wash contaminated clothing before reuse. Do not eat, drink or smoke when using this product.
Always wash hands after handling the product.
7.2. Conditions for safe storage, including any incompatibilities
Storage conditions Keep cool. Store in a dry place.
Storage temperature 41 - 77 °F
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
No additional information available
8.2. Exposure controls
Personal protective equipment Protective clothing. Safety glasses. Gloves.
Hand protection Protective gloves. EN 374.
Eye protection Safety glasses. EN 166. EN 170.
Skin and body protection Wear suitable protective clothing.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
Physical state Liquid
Appearance Pasty.
Colour red white Grey
Odour characteristic
Odour threshold Not determined
pH ≈ 9 Not applicable
Melting point Not applicable
Freezing point No data available
Boiling point No data available
Flash point Not applicable
Relative evaporation rate (butylacetate=1) No data available
Flammability (solid, gas) No data available
Explosive limits No data available
Explosive properties No data available
Oxidising properties No data available
Vapour pressure No data available
Relative density No data available
Relative vapour density at 20 °C No data available
Density 1.6 g/cm³
Molecular mass Not determined
Solubility No data available
05/21/2019
Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
07/01/2016 EN (English) 4/7
Log Pow No data available
Auto-ignition temperature No data available
Decomposition temperature No data available
Viscosity No data available
Viscosity, kinematic No data available
Viscosity, dynamic No data available
9.2. Other information
No additional information available
SECTION 10: Stability and reactivity
10.1. Reactivity
The product is non-reactive under normal conditions of use, storage and transport.
10.2. Chemical stability
Stable under normal conditions.
10.3. Possibility of hazardous reactions
No dangerous reactions known under normal conditions of use.
10.4. Conditions to avoid
None under recommended storage and handling conditions (see section 7).
10.5. Incompatible materials
No additional information available
10.6. Hazardous decomposition products
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
SECTION 11: Toxicological information
11.1. Information on toxicological effects
Acute toxicity Not classified
Skin corrosion/irritation Not classified
pH: ≈ 9 Not applicable
Serious eye damage/irritation Not classified
pH: ≈ 9 Not applicable
Respiratory or skin sensitisation Not classified
Germ cell mutagenicity Not classified
Carcinogenicity Not classified
Reproductive toxicity Not classified
Specific target organ toxicity (single exposure) Not classified
Specific target organ toxicity (repeated
exposure)
Not classified
Aspiration hazard Not classified
05/21/2019
Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
07/01/2016 EN (English) 5/7
SECTION 12: Ecological information
12.1. Toxicity
Ecology - general The product is not considered harmful to aquatic organisms or to cause long-term adverse
effects in the environment.
12.2. Persistence and degradability
No additional information available
12.3. Bioaccumulative potential
No additional information available
12.4. Mobility in soil
No additional information available
12.5. Other adverse effects
Effect on the global warming No known ecological damage caused by this product.
SECTION 13: Disposal considerations
13.1. Waste treatment methods
Waste treatment methods Dispose of contents/container in accordance with licensed collector’s sorting instructions.
Waste disposal recommendations Dispose in a safe manner in accordance with local/national regulations.
SECTION 14: Transport information
In accordance with ADR / RID / IMDG / IATA / ADN
14.1. UN number
Not regulated for transport
14.2. UN proper shipping name
Proper Shipping Name (ADR) Not applicable
Proper Shipping Name (IMDG) Not applicable
Proper Shipping Name (IATA) Not applicable
Proper Shipping Name (ADN) Not applicable
Proper Shipping Name (RID) Not applicable
14.3. Transport hazard class(es)
ADR
Transport hazard class(es) (ADR) Not applicable
IMDG
Transport hazard class(es) (IMDG) Not applicable
IATA
Transport hazard class(es) (IATA) Not applicable
ADN
Transport hazard class(es) (ADN) Not applicable
RID
05/21/2019
Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
07/01/2016 EN (English) 6/7
Transport hazard class(es) (RID) Not applicable
14.4. Packing group
Packing group (ADR) Not applicable
Packing group (IMDG) Not applicable
Packing group (IATA) Not applicable
Packing group (ADN) Not applicable
Packing group (RID) Not applicable
14.5. Environmental hazards
Dangerous for the environment No
Marine pollutant No
Other information No supplementary information available
14.6. Special precautions for user
- Overland transport
- Transport by sea
No data available
- Air transport
No data available
- Inland waterway transport
Carriage prohibited (ADN) No
Not subject to ADN No
- Rail transport
Carriage prohibited (RID) No
14.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
SECTION 15: Regulatory information
15.1. US Federal regulations
This product or mixture does not contain a toxic chemical or chemicals in excess of the applicable de minimis concentration as specified in 40 CFR
§372.38(a) subject to the reporting requirements of section 313 of Title III of the Superfund Am endments and Reauthorization Act of 1986 and 40
CFR Part 372.
15.2. International regulations
CANADA
Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606
WHMIS Classification Uncontrolled product according to WHMIS classification criteria
EU-Regulations
No additional information available
Classification according to Regulation (EC) No. 1272/2008 [CLP]
Not classified
National regulations
No additional information available
05/21/2019
Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
07/01/2016 EN (English) 7/7
15.3. US State regulations
California Proposition 65 - This product does not contain any substances known to the state of California to cause
cancer, developmental and/or reproductive harm
SECTION 16: Other information
Revision date 01/07/2016
HMIS III Rating
Health 0 Minimal Hazard - No significant risk to health
Flammability 0 Minimal Hazard - Materials that will not burn
Physical 0 Minimal Hazard - Materials that are normally stable, even under fire conditions, and will NOT
react with water, polymerize, decompose, condense, or self -react. Non-Explosives.
Personal Protection B
B - Safety glasses, Gloves
SDS_US_Hilti
This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and
environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product
05/21/2019
Hilti, Inc.
5400 South 122nd East Avenue
Tulsa, OK 74146
1-800-879-8000
www.hilti.com
February 26, 2010
To Whom It May Concern:
Re: Hilti CP 606 Flexible Firestop – LEEDs Info.
The Hilti CP 606 Flexible Firestop Sealant is manufactured in Germany.
The CP 606 pail is made of polyethylene and can be completely recycled. There is no post-
consumer or post-industrial content in CP 606 and it cannot be recycled. The CP 606 does not
contain any Rapidly Renewable Materials. The VOC content for CP 606 is 71.0 grams/liter.
CP 606 is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for
the disposal of non-regulated industrial waste can vary from state to state and even city to city.
For this reason, you should consult your local and state regulatory agencies for direction on
disposal.
Please feel free to contact me at (918) 872-3704 if you have questions.
Sincerely,
Jerry Metcalf MPH, CHMM
Safety/Environmental Manager
Hilti Inc.
918 872 3704
jerry.metcalf@hilti.com
Rev. Date: 2/26/10
05/21/2019
Hilti Firestop
Saving lives
through innovation
and education
Product Information
Hilti. Outperform. Outlast.
Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide
In
t
r
o
d
u
c
t
i
o
n
Ap
p
l
i
c
a
t
i
o
n
s
a
n
d
P
r
o
d
u
c
t
s
Se
l
e
c
t
o
r
G
u
i
d
e
Th
r
o
u
g
h
-
P
e
n
e
t
r
a
t
i
o
n
Jo
i
n
t
Re
f
e
r
e
n
c
e
D
a
t
a
Firestop Collar (CP 643N)
Product description
■A ready-to-use firestop collar, made of a galvanized steel housing
and intumescent inserts for firestopping combustible pipes
Product features
■Ready-to-use collar
■No construction required
■Fast installation time
■Adjustable mounting tabs
■Low profile for tight installations
Areas of application
■Firestopping combustible pipes up to 6" diameter in penetrations
through fire walls and floors
■Suitable for the following pipe materials:
■ PVC, CPVC, ABS, PVDF, PP and FRPP
For use with
■Concrete, masonry, wood floor and gypsum wall assemblies
■Wall and floor assemblies rated up to 4 hours
Types of installation
■Wall: two collars, one on each side
■Floor: one collar on underside (bottom)
Example
■Waste water pipes
■Fresh water pipes
Installation instructions for CP 643N
VRGIPHYL
-
G
M
I
L
Z
K
U
L
X
K
1|R:(
==DZ|
S
L
H
X X
]
H
LNLUGZLOR
L
M
W
I
|
[
Y
E
Y
E
Y
K
LUHLY
XRHR
R
&3%UD
Q
G
V
F
K
X
W
]
P
D
Q
V
F
K
Notice
• Before handling, read Material Safety Data Sheet and
product label for safe usage and health information.
• Instructions below are general guidelines — always
refer to the applicable drawing in the UL Fire
Resistance Directory or Hilti Firestop Systems Guide
for complete installation information
Opening
1. Clean the plastic pipes. Expansion of the
intumescent material during a fire acts to close the
plastic pipe. Very dirty pipes (ie: with remains of
mortar) may lead to a delay in this closing action.
Soiled plastic pipes should, therefore, be cleaned in
the area where the CP 643N Firestop Collar is to be
installed.
Application of firestop system
2. Seal the opening if required. Gaps may be closed
with FS-ONE. The approved methods vary and are
given in the specific UL system.
3. Close the CP 643N Firestop Collar. Place the
CP 643N Firestop Collar around the plastic pipe
and lock the closure by applying firm pressure until
it latches.
4. Attach fastening hooks. The fastening hooks can
be attached to various points on the metal hous ing.
This allows the fastening points to be made to suit
the space available in each case. The hooks must
be positioned as symmetrically as possible. The
required number of fastening hooks is indicated on
the packaging.
5. Fastening the CP 643N Firestop Collar. Only when
fastened properly can CP 643N offer protection
against fire.
a. Mark the fastening points.
b. Drill holes with a Hilti rotary hammer drill (i.e.
TE 4-A18) or, depending on base material, fasten
using Hilti powder-actuated tool.
c. To secure the CP 643N Firestop Collar, use Hilti
anchors/fasteners.
d. For maintenance reasons, a penetration can be
permanently marked with an identification plate and
fastened in a visible position next to the seal.
Not for use
• With metal pipes
• In highly corrosive surroundings
• With unapproved anchors/fasteners
Storage
• Store only in the original packaging in a location
protected from moisture
1. Clean plastic pipe.2. Close remaining gap to
provide smoke and gas
resistant seal.
3. Close collar.4. Attach fastening hooks.5. Fasten collar and
identification plate
(if required).
)LUHVWRS6\VWHP
FM
$33529('
)RU3HQHWUDWLRQ)LUH6WRSV
&RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH
R
FILL, VOID OR CAVITY MATERIALS
CLASSIFIED BY
UNDERWRITERS LABORATORIES, INC.
FOR USE IN TROUGH-PENETRATION
FIRESTOP SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
66Y7
FIRESTOP DEVICE
FOR USE IN THROUGH-PENETRATION
FIRESTOP SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
5N76
Technical Data CP 643N
Pipe
outside
Description dia (in.)
Collar Collar No. of
outside Height hooks and
dia. (in.) (in.) fasteners
CP 643-50/1.5"N 1.4–2.0 2.8 0.9 2
CP 643-63/2"N 2.0–2.5 3.4 1.3 2
CP 643-90/3"N 2.6–3.6 4.9 1.7 3
CP 643-110/4"N 3.6–4.5 6.0 1.9 3
CP 643-160/6"N 6.6 9.8 1.9 4
Temperature resistance -40°F to 140°F (–40°C to 60°C)
Intumescent activation Approx. 392°F (200°C)
Expansion ratio (unrestricted)Up to 1:10
Tested in accordance with
• UL 1479 • ASTM E 814 • ASTM G21
Visit fbcsystemcompatible.com.
FBC™ is a trademark of
the Lubrizol Corporation.
05/21/2019
CERTIFICATE OF COMPLIANCE
Certificate Number 20160125-R15431
Report Reference R15431-19980323
Issue Date 2016-JANUARY-25
Bruce Mahrenholz, Director North American Certification Program
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 1
Issued to: HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC
5400 S 122ND EAST AVE
TULSA OK 74146
This is to certify that
representative samples of
FIRESTOP DEVICES
Firestop devices designated CP 643 50/1.5” N, CP 643
63/2” N, CP 643 75/2.5” N, CP 643 90/3” N, CP 643 110/4”
N, CP 643 125/5” N, CP 643 160/6” N, CP 644 200/8” and
CP 644 250/10” for use in specific through-penetration
firestop systems. The various suffixes for the designations
of the firestop devices indicates the nominal outside
diameter of the pipe (mm/in.) on which the device is
intended to be installed.
Have been investigated by UL in accordance with the
Standard(s) indicated on this Certificate.
Standard(s) for Safety: UL 1479 STANDARD FOR FIRE TESTS OF
PENETRATION FIRESTOPS.
CAN/ULC S115 STANDARD METHOD OF FIRE TESTS
OF FIRESTOP SYSTEMS
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information
Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.
Look for the UL Certification Mark on the product.
05/21/2019
Page 1/5
Safety Data Sheet
acc. to ISO 11014
Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3
40.2.7
* 1 Identification
· Product identifier
· Trade name:
Hilti Firestop Collar CFS-C
Hilti Firestop Collar Plus CFS-C P
Hilti Firestop Bandage CFS-B
Hilti Firestop Wrap Strip Endless CFS-W EL
Hilti Firestop Wrap Strip Single CFS-W SG
Hilti Firestop Collar Endless CFS-C EL
Hilti Firestop Back Pan Strip CFS-BPS
CP 643
CP 644
CP 646
CP 648
· Relevant identified uses of the substance or mixture and uses advised against No further relevant information available.
· Application of the substance / the mixture Construction chemicals
· Details of the supplier of the safety data sheet
· Manufacturer/Supplier:
Hilti, Inc.
5400 South 122nd East Ave.
US-Tulsa, OK 74146
Phone: (800) 879-8000
Fax: (800) 879-7000
Español: (800) 879-5000
· Information department:
see section 16
chemicals.hse@hilti.com
· Emergency telephone number:
Tox Info Suisse - 24 h Service
Tel.: 0041 / 44 251 51 51 (international)
.
Chem-Trec
Tel.: 1 800 424 9300
2 Hazard(s) identification
· Classification of the substance or mixture The product is not classified according to the Globally Harmonized System (GHS).
· Classification according to Directive 67/548/EEC or Directive 1999/45/EC not applicable
· Information concerning particular hazards for human and environment:
The product does not have to be labelled due to the calculation procedure of the "General Classification guideline for preparations of the EU" in
the latest valid version.
· Classification system:
The classification was made according to the latest editions of the EU-lists, and expanded upon from company and literature data.
· Label elements
· GHS label elements Void
· Hazard pictograms Void
· Signal word Void
· Hazard statements Void
· Other hazards
· Results of PBT and vPvB assessment
· PBT:Not applicable.
· vPvB:Not applicable.
* 3 Composition/information on ingredients
· Chemical characterization: Mixtures
· Description:Polymer-bonded intumescent material (in the metal or plastic housing)
· Dangerous components:Void
4 First-aid measures
· Description of first aid measures
· General information No special measures required.
· After inhalation Not applicable
· After skin contact Not applicable
· After eye contact Not applicable
· After swallowing Not applicable
· Information for doctor
· Most important symptoms and effects, both acute and delayed No further relevant information available.
· Indication of any immediate medical attention and special treatment needed No further relevant information available.
US
(Contd. on page 2)
05/21/2019
Page 2/5
Safety Data Sheet
acc. to ISO 11014
Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3
(Contd. of page 1)
40.2.7
5 Fire-fighting measures
· Extinguishing media
· Suitable extinguishing agents CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
· Special hazards arising from the substance or mixture No further relevant information available.
· Advice for firefighters
· Protective equipment:No special measures required.
6 Accidental release measures
· Personal precautions, protective equipment and emergency procedures Not required.
· Environmental precautions:No special measures required.
· Methods and material for containment and cleaning up:Pick up mechanically.
· Reference to other sections
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
7 Handling and storage
· Handling
· Precautions for safe handling No special measures required.
· Information about protection against explosions and fires:No special measures required.
· Conditions for safe storage, including any incompatibilities
· Storage
· Requirements to be met by storerooms and receptacles:No special requirements.
· Information about storage in one common storage facility:Not required.
· Further information about storage conditions:None.
· Storage class 13
· Specific end use(s)No further relevant information available.
8 Exposure controls/personal protection
· Control parameters
· Components with limit values that require monitoring at the workplace:
The product does not contain any relevant quantities of materials with critical values that have to be monitored at the workplace.
· Additional information:The lists that were valid during the creation were used as basis.
· Exposure controls
· Personal protective equipment
· Breathing equipment:Not required.
· Protection of hands:
Protective gloves.
To avoid skin problems reduce the wearing of gloves to the required minimum.
· Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to
manufacturer.
· Penetration time of glove material Not required.
· Body protection:
Protective work clothing.
9 Physical and chemical properties
· Information on basic physical and chemical properties
· General Information
· Appearance:
Form:Solid.
Color:Various colors
· Odor:Odorless
· pH-value:Not determined.
· Change in condition
Melting point/Melting range:Not determined.
(Contd. on page 3)
US
05/21/2019
Page 3/5
Safety Data Sheet
acc. to ISO 11014
Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3
(Contd. of page 2)
40.2.7
Boiling point/Boiling range:undetermined
· Flash point:Not applicable
· Flammability (solid, gaseous)Product is not flammable.
· Ignition temperature:
Decomposition temperature:Not determined.
· Danger of explosion:Product does not present an explosion hazard.
· Vapor pressure:Not applicable.
· Density at 20 °C (68 °F):1.3-1.4 g/cm³ (10.849-11.68 lbs/gal)
· Evaporation rate Not applicable.
· Solubility in / Miscibility with
Water:Insoluble
· Partition coefficient (n-octanol/water):Not determined.
· Viscosity:
dynamic:Not applicable.
kinematic:Not applicable.
· Solvent content:
Solids content:100 %
· Other information CP 643, CP 644 - VOC Content: 7.6 g/l (EPA Method 24)
CP 648, CFS-BPS - VOC Content: 3.1 g/l (EPA Method 24)
10Stability and reactivity
· Reactivity
· Chemical stability
· Thermal decomposition / conditions to be avoided:No decomposition if used according to specifications.
· Possibility of hazardous reactions No dangerous reactions known
· Conditions to avoid No further relevant information available.
· Incompatible materials:No further relevant information available.
· Hazardous decomposition products:No dangerous decomposition products known
11Toxicological information
· Information on toxicological effects
· Acute toxicity:
· Primary irritant effect:
· on the skin:No irritant effect.
· on the eye:No irritating effect.
· Sensitization:No sensitizing effects known.
· Additional toxicological information:
When used and handled according to specifications, the product does not have any harmful effects according to our experience and the
information provided to us.
· IARC (International Agency for Research on Cancer)
None of the ingredients is listed.
· NTP (National Toxicology Program)
None of the ingredients is listed
· OSHA-Ca (Occupational Safety & Health Administration)
None of the ingredients is listed.
12Ecological information
· Toxicity
· Aquatic toxicity:No further relevant information available.
· Persistence and degradability No further relevant information available.
· Behavior in environmental systems:
· Bioaccumulative potential No further relevant information available.
· Mobility in soil No further relevant information available.
· Ecotoxical effects:Not determined
· Results of PBT and vPvB assessment
· PBT:Not applicable.
· vPvB:Not applicable.
· Other adverse effects No further relevant information available.
US
(Contd. on page 4)
05/21/2019
Page 4/5
Safety Data Sheet
acc. to ISO 11014
Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3
(Contd. of page 3)
40.2.7
13Disposal considerations
· Waste treatment methods
· Recommendation Smaller quantities can be disposed of with household waste.
· European waste catalogue:
17 02 03 plastic
17 04 05 iron and steel
· Uncleaned packagings:
· Recommendation:
Disposal must be made according to official regulations.
Dispose of packaging according to regulations on the disposal of packagings.
Empty packs: May be disposed via the local Green Dot collecting system or EAK waste material code 150102 (plastic packaging materials)
14Transport information
· UN-Number
· DOT, ADR, ADN, IMDG, IATA Void
· UN proper shipping name
· DOT, ADR, ADN, IMDG, IATA Void
· Transport hazard class(es)
· DOT, ADR, ADN, IMDG, IATA
· Class Void
· Packing group
· DOT, ADR, IMDG, IATA Void
· Environmental hazards:
· Marine pollutant:No
· Special precautions for user Not applicable
· Transport in bulk according to Annex II of MARPOL73/78 and
the IBC Code Not applicable.
· Transport/Additional information:Not dangerous according to the above specifications.
· UN "Model Regulation":-
15Regulatory information
· Safety, health and environmental regulations/legislation specific for the substance or mixture
· Sara
· Section 355 (Extremely hazardous substances):
None of the ingredients is listed.
· Section 313 (Specific toxic chemical listings):
None of the ingredients are listed.
· TSCA (Toxic Substances Control Act):
All ingredients are listed.
· Proposition 65:
· Chemicals known to cause cancer:
None of the ingredients are listed.
· Cancerogenity categories
· EPA (Environmental Protection Agency)
None of the ingredients is listed.
· TLV (Threshold Limit Value established by ACGIH)
None of the ingredients is listed.
· MAK (German Maximum Workplace Concentration)
None of the ingredients is listed.
· NIOSH-Ca (National Institute for Occupational Safety and Health)
None of the ingredients is listed.
· Chemical safety assessment:not required.
16Other information
This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall
not establish a legally valid contractual relationship.
· Department issuing SDS:
Hilti Corporation
Business Unit Chemicals
Quality/Safety/Environment
(Contd. on page 5)
US
05/21/2019
Page 5/5
Safety Data Sheet
acc. to ISO 11014
Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3
(Contd. of page 4)
40.2.7
FL-9494 Schaan / Liechtenstein
chemicals.hse@hilti.com
Tel.: +423 234 3004
FAX.: +423 234 3462
· Date of preparation / last revision 05/18/2015 / 2
· Abbreviations and acronyms:
ADR: Accord européen sur le transport des marchandises dangereuses par Route (European Agreement concerning the International Carriage of Dangerous Goods by Road)
IMDG: International Maritime Code for Dangerous Goods
DOT: US Department of Transportation
IATA: International Air Transport Association
ACGIH: American Conference of Governmental Industrial Hygienists
EINECS: European Inventory of Existing Commercial Chemical Substances
ELINCS: European List of Notified Chemical Substances
CAS: Chemical Abstracts Service (division of the American Chemical Society)
· * Data compared to the previous version altered.
US
05/21/2019
Hilti, Inc.
5400 South 122nd East Avenue
Tulsa, OK 74146
1 -800-879-8000
www.hilti.com
August 26, 2015
To Whom It May Concern:
Re: CP 643N/644 Firestop Collars – LEED Information
Item Numbers:
304325
304326
304328
304329
304331
304341
304344
The Hilti CP 643N/644 Firestop Collars are manufactured in Germany.
The Hilti CP 643N/644 Firestop Collars have a VOC content of 7.6 grams/liter.
The amount of post-consumer or post-industrial content in CP 643N/644 Firestop Collars is not known. The metal portions of the
collars are recyclable. The CP 643N/644 Firestop Collars do not contain any Rapidly Renewable Materials.
The CP 643N/644 Firestop Collars are not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the
disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult
your local and state regulatory agencies for direction on disposal.
Please feel free to contact me at (918) 872-3704 if you have questions.
Sincerely,
Jerry Metcalf MPH, CHMM
Sr. Manager, Safety/Environmental
Hilti Inc.
(918) 872 3704
jerry.metcalf@hilti.com
Rev. Date: 8/14/15
The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.
The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.
Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.
05/21/2019
Hilti Firestop
Saving lives
through innovation
and education
Product Information
Hilti. Outperform. Outlast.
Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide
Firestop Collar (CP 644)
Product description
■A ready-to-use firestop collar, made of galvanized steel housing
and intumescent inserts for firestopping large combustible pipes
Product features
■Ready-to-use collar
■No construction required
■Fast installation time
■Adjustable/moveable fastening tabs
Areas of application
■Sealing of penetrations for combustible pipes from 8" to 10" in
diameter
■Vented or closed pipe
■PVC or CPVC pipe
For use with
■Concrete, masonry, and gypsum walls
■Wall and floor assemblies rated up to 2 hours
Types of installation
■Wall: two collars, one on each side
■Floor: one collar on underside (bottom)
Examples
■Waste water pipes
■Fresh water pipes
Installation instructions for CP 644
VRGIPHY
L
-
G
M
I
L
Z
K
U
L
XK1|R:
(
==DZ|
S
LH
X
X
]
H
LNLUGZLOR
L
M
W
I
|
[YEYEYK
L
U
H
L
Y
XRH
R
R
&3%UD
Q
G
V
F
KXW]PDQVF
K
Notice
• Before handling, read Material Safety Data Sheet and
product label for safe usage and health information.
• Instructions below are general guidelines — always
refer to the applicable drawing in the UL Fire
Resistance Directory or Hilti Firestop Systems Guide
for complete installation information
Opening
1. Clean the plastic pipes. Expansion of the
intumescent material during a fire acts to close the
plastic pipe. Very dirty pipes, (ie: with remains of
mortar) may lead to a delay in this closing action.
Soiled plastic pipes should, therefore, be cleaned in
the area where the CP 644 Firestop Collar is to be
installed.
Application of firestop system
2. Seal the opening. Gaps must be closed with FS-
ONE. The approved methods vary and are given in
the specific UL system.
3. Close the CP 644 Firestop Collar. Place the CP 644
Firestop Collar around the plastic pipe and lock the
closure by applying firm pressure until it latches.
4. Attach fastening hooks. The fastening hooks can
be attached to various points on the metal hous ing.
This allows the fastening points to be made to suit
the space available in each case.
The hooks must be positioned as symmetrically as
possible. The required number of fastening hooks is
indicated on the packaging.
5. Fastening the CP 644 Firestop Collar. Only when
fastened properly can CP 644 offer protection
against fire passing through.
a. Mark the fastening points.
b. Drill holes with a Hilti rotary hammer drill
(i.e. TE 4-A18) or, depending on base material,
fasten using Hilti powder-actuated tool.
c. To secure the CP 644 Firestop Collar, use Hilti
anchors/fasteners.
d. For maintenance reasons, a penetration can be
permanently marked with an identification plate
and fastened in a visible position next to the seal.
Not for use
• With metal pipes
• In highly corrosive surroundings
• With unapproved anchors/fasteners
Storage
• Store only in the original packaging in a location
protected from moisture
FIRESTOP DEVICE
FOR USE IN THROUGH-PENETRATION
FIRESTOP SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
5N76
)LUHVWRS6\VWHP
Technical Data CP 644
Pipe
outside
Description dia (in.)
Collar Collar No. of
outside Height hooks and
dia. (in.) (in.) fasteners
CP 644-200/8" 8.8 10.0 6.9 10
CP 644-250/10" 10.8 12.4 9.1 12
Temperature resistance -40°F to 140°F (–40°C to 60°C)
Intumescent Activation Approx. 392°F (200°C)
Expansion ratio (unrestricted)Up to 1:10
Tested in accordance with
• UL 1479 • ASTM E 814 • ASTM G21
1. Clean plastic pipe 2. Close remaining gap to
provide smoke and gas
resistant seal
3. Close collar 4. Attach fastening hooks 5. Fasten collar and
identification plate. (If
required)
05/21/2019
CERTIFICATE OF COMPLIANCE
Certificate Number 20160125-R15431
Report Reference R15431-19980323
Issue Date 2016-JANUARY-25
Bruce Mahrenholz, Director North American Certification Program
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 1
Issued to: HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC
5400 S 122ND EAST AVE
TULSA OK 74146
This is to certify that
representative samples of
FIRESTOP DEVICES
Firestop devices designated CP 643 50/1.5” N, CP 643
63/2” N, CP 643 75/2.5” N, CP 643 90/3” N, CP 643 110/4”
N, CP 643 125/5” N, CP 643 160/6” N, CP 644 200/8” and
CP 644 250/10” for use in specific through-penetration
firestop systems. The various suffixes for the designations
of the firestop devices indicates the nominal outside
diameter of the pipe (mm/in.) on which the device is
intended to be installed.
Have been investigated by UL in accordance with the
Standard(s) indicated on this Certificate.
Standard(s) for Safety: UL 1479 STANDARD FOR FIRE TESTS OF
PENETRATION FIRESTOPS.
CAN/ULC S115 STANDARD METHOD OF FIRE TESTS
OF FIRESTOP SYSTEMS
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information
Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.
Look for the UL Certification Mark on the product.
05/21/2019
Page 1/5
Safety Data Sheet
acc. to ISO 11014
Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3
40.2.7
* 1 Identification
· Product identifier
· Trade name:
Hilti Firestop Collar CFS-C
Hilti Firestop Collar Plus CFS-C P
Hilti Firestop Bandage CFS-B
Hilti Firestop Wrap Strip Endless CFS-W EL
Hilti Firestop Wrap Strip Single CFS-W SG
Hilti Firestop Collar Endless CFS-C EL
Hilti Firestop Back Pan Strip CFS-BPS
CP 643
CP 644
CP 646
CP 648
· Relevant identified uses of the substance or mixture and uses advised against No further relevant information available.
· Application of the substance / the mixture Construction chemicals
· Details of the supplier of the safety data sheet
· Manufacturer/Supplier:
Hilti, Inc.
5400 South 122nd East Ave.
US-Tulsa, OK 74146
Phone: (800) 879-8000
Fax: (800) 879-7000
Español: (800) 879-5000
· Information department:
see section 16
chemicals.hse@hilti.com
· Emergency telephone number:
Tox Info Suisse - 24 h Service
Tel.: 0041 / 44 251 51 51 (international)
.
Chem-Trec
Tel.: 1 800 424 9300
2 Hazard(s) identification
· Classification of the substance or mixture The product is not classified according to the Globally Harmonized System (GHS).
· Classification according to Directive 67/548/EEC or Directive 1999/45/EC not applicable
· Information concerning particular hazards for human and environment:
The product does not have to be labelled due to the calculation procedure of the "General Classification guideline for preparations of the EU" in
the latest valid version.
· Classification system:
The classification was made according to the latest editions of the EU-lists, and expanded upon from company and literature data.
· Label elements
· GHS label elements Void
· Hazard pictograms Void
· Signal word Void
· Hazard statements Void
· Other hazards
· Results of PBT and vPvB assessment
· PBT:Not applicable.
· vPvB:Not applicable.
* 3 Composition/information on ingredients
· Chemical characterization: Mixtures
· Description:Polymer-bonded intumescent material (in the metal or plastic housing)
· Dangerous components:Void
4 First-aid measures
· Description of first aid measures
· General information No special measures required.
· After inhalation Not applicable
· After skin contact Not applicable
· After eye contact Not applicable
· After swallowing Not applicable
· Information for doctor
· Most important symptoms and effects, both acute and delayed No further relevant information available.
· Indication of any immediate medical attention and special treatment needed No further relevant information available.
US
(Contd. on page 2)
05/21/2019
Page 2/5
Safety Data Sheet
acc. to ISO 11014
Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3
(Contd. of page 1)
40.2.7
5 Fire-fighting measures
· Extinguishing media
· Suitable extinguishing agents CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
· Special hazards arising from the substance or mixture No further relevant information available.
· Advice for firefighters
· Protective equipment:No special measures required.
6 Accidental release measures
· Personal precautions, protective equipment and emergency procedures Not required.
· Environmental precautions:No special measures required.
· Methods and material for containment and cleaning up:Pick up mechanically.
· Reference to other sections
See Section 8 for information on personal protection equipment.
See Section 13 for disposal information.
7 Handling and storage
· Handling
· Precautions for safe handling No special measures required.
· Information about protection against explosions and fires:No special measures required.
· Conditions for safe storage, including any incompatibilities
· Storage
· Requirements to be met by storerooms and receptacles:No special requirements.
· Information about storage in one common storage facility:Not required.
· Further information about storage conditions:None.
· Storage class 13
· Specific end use(s)No further relevant information available.
8 Exposure controls/personal protection
· Control parameters
· Components with limit values that require monitoring at the workplace:
The product does not contain any relevant quantities of materials with critical values that have to be monitored at the workplace.
· Additional information:The lists that were valid during the creation were used as basis.
· Exposure controls
· Personal protective equipment
· Breathing equipment:Not required.
· Protection of hands:
Protective gloves.
To avoid skin problems reduce the wearing of gloves to the required minimum.
· Material of gloves
The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to
manufacturer.
· Penetration time of glove material Not required.
· Body protection:
Protective work clothing.
9 Physical and chemical properties
· Information on basic physical and chemical properties
· General Information
· Appearance:
Form:Solid.
Color:Various colors
· Odor:Odorless
· pH-value:Not determined.
· Change in condition
Melting point/Melting range:Not determined.
(Contd. on page 3)
US
05/21/2019
Page 3/5
Safety Data Sheet
acc. to ISO 11014
Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3
(Contd. of page 2)
40.2.7
Boiling point/Boiling range:undetermined
· Flash point:Not applicable
· Flammability (solid, gaseous)Product is not flammable.
· Ignition temperature:
Decomposition temperature:Not determined.
· Danger of explosion:Product does not present an explosion hazard.
· Vapor pressure:Not applicable.
· Density at 20 °C (68 °F):1.3-1.4 g/cm³ (10.849-11.68 lbs/gal)
· Evaporation rate Not applicable.
· Solubility in / Miscibility with
Water:Insoluble
· Partition coefficient (n-octanol/water):Not determined.
· Viscosity:
dynamic:Not applicable.
kinematic:Not applicable.
· Solvent content:
Solids content:100 %
· Other information CP 643, CP 644 - VOC Content: 7.6 g/l (EPA Method 24)
CP 648, CFS-BPS - VOC Content: 3.1 g/l (EPA Method 24)
10Stability and reactivity
· Reactivity
· Chemical stability
· Thermal decomposition / conditions to be avoided:No decomposition if used according to specifications.
· Possibility of hazardous reactions No dangerous reactions known
· Conditions to avoid No further relevant information available.
· Incompatible materials:No further relevant information available.
· Hazardous decomposition products:No dangerous decomposition products known
11Toxicological information
· Information on toxicological effects
· Acute toxicity:
· Primary irritant effect:
· on the skin:No irritant effect.
· on the eye:No irritating effect.
· Sensitization:No sensitizing effects known.
· Additional toxicological information:
When used and handled according to specifications, the product does not have any harmful effects according to our experience and the
information provided to us.
· IARC (International Agency for Research on Cancer)
None of the ingredients is listed.
· NTP (National Toxicology Program)
None of the ingredients is listed
· OSHA-Ca (Occupational Safety & Health Administration)
None of the ingredients is listed.
12Ecological information
· Toxicity
· Aquatic toxicity:No further relevant information available.
· Persistence and degradability No further relevant information available.
· Behavior in environmental systems:
· Bioaccumulative potential No further relevant information available.
· Mobility in soil No further relevant information available.
· Ecotoxical effects:Not determined
· Results of PBT and vPvB assessment
· PBT:Not applicable.
· vPvB:Not applicable.
· Other adverse effects No further relevant information available.
US
(Contd. on page 4)
05/21/2019
Page 4/5
Safety Data Sheet
acc. to ISO 11014
Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3
(Contd. of page 3)
40.2.7
13Disposal considerations
· Waste treatment methods
· Recommendation Smaller quantities can be disposed of with household waste.
· European waste catalogue:
17 02 03 plastic
17 04 05 iron and steel
· Uncleaned packagings:
· Recommendation:
Disposal must be made according to official regulations.
Dispose of packaging according to regulations on the disposal of packagings.
Empty packs: May be disposed via the local Green Dot collecting system or EAK waste material code 150102 (plastic packaging materials)
14Transport information
· UN-Number
· DOT, ADR, ADN, IMDG, IATA Void
· UN proper shipping name
· DOT, ADR, ADN, IMDG, IATA Void
· Transport hazard class(es)
· DOT, ADR, ADN, IMDG, IATA
· Class Void
· Packing group
· DOT, ADR, IMDG, IATA Void
· Environmental hazards:
· Marine pollutant:No
· Special precautions for user Not applicable
· Transport in bulk according to Annex II of MARPOL73/78 and
the IBC Code Not applicable.
· Transport/Additional information:Not dangerous according to the above specifications.
· UN "Model Regulation":-
15Regulatory information
· Safety, health and environmental regulations/legislation specific for the substance or mixture
· Sara
· Section 355 (Extremely hazardous substances):
None of the ingredients is listed.
· Section 313 (Specific toxic chemical listings):
None of the ingredients are listed.
· TSCA (Toxic Substances Control Act):
All ingredients are listed.
· Proposition 65:
· Chemicals known to cause cancer:
None of the ingredients are listed.
· Cancerogenity categories
· EPA (Environmental Protection Agency)
None of the ingredients is listed.
· TLV (Threshold Limit Value established by ACGIH)
None of the ingredients is listed.
· MAK (German Maximum Workplace Concentration)
None of the ingredients is listed.
· NIOSH-Ca (National Institute for Occupational Safety and Health)
None of the ingredients is listed.
· Chemical safety assessment:not required.
16Other information
This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall
not establish a legally valid contractual relationship.
· Department issuing SDS:
Hilti Corporation
Business Unit Chemicals
Quality/Safety/Environment
(Contd. on page 5)
US
05/21/2019
Page 5/5
Safety Data Sheet
acc. to ISO 11014
Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3
(Contd. of page 4)
40.2.7
FL-9494 Schaan / Liechtenstein
chemicals.hse@hilti.com
Tel.: +423 234 3004
FAX.: +423 234 3462
· Date of preparation / last revision 05/18/2015 / 2
· Abbreviations and acronyms:
ADR: Accord européen sur le transport des marchandises dangereuses par Route (European Agreement concerning the International Carriage of Dangerous Goods by Road)
IMDG: International Maritime Code for Dangerous Goods
DOT: US Department of Transportation
IATA: International Air Transport Association
ACGIH: American Conference of Governmental Industrial Hygienists
EINECS: European Inventory of Existing Commercial Chemical Substances
ELINCS: European List of Notified Chemical Substances
CAS: Chemical Abstracts Service (division of the American Chemical Society)
· * Data compared to the previous version altered.
US
05/21/2019
Hilti, Inc.
5400 South 122nd East Avenue
Tulsa, OK 74146
1 -800-879-8000
www.hilti.com
August 26, 2015
To Whom It May Concern:
Re: CP 643N/644 Firestop Collars – LEED Information
Item Numbers:
304325
304326
304328
304329
304331
304341
304344
The Hilti CP 643N/644 Firestop Collars are manufactured in Germany.
The Hilti CP 643N/644 Firestop Collars have a VOC content of 7.6 grams/liter.
The amount of post-consumer or post-industrial content in CP 643N/644 Firestop Collars is not known. The metal portions of the
collars are recyclable. The CP 643N/644 Firestop Collars do not contain any Rapidly Renewable Materials.
The CP 643N/644 Firestop Collars are not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the
disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult
your local and state regulatory agencies for direction on disposal.
Please feel free to contact me at (918) 872-3704 if you have questions.
Sincerely,
Jerry Metcalf MPH, CHMM
Sr. Manager, Safety/Environmental
Hilti Inc.
(918) 872 3704
jerry.metcalf@hilti.com
Rev. Date: 8/14/15
The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.
The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.
Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.
05/21/2019
Product information
Hilti, Inc. (USA) 1-800-879-8000 I www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca
Hilti. Outperform. Outlast.
High-performance intumescent firestop sealant FS-ONE MAX
Applications
■For effectively sealing most common through penetrations in a variety
of base materials
■For use on concrete, masonry and drywall
■Mixed and multiple penetrations
■Metal pipe penetrations: copper, steel and EMT
■Insulated metal pipe penetrations: steel and copper
■Plastic pipe penetrations: closed or vented
Advantages
■US-produced: “Buy American” compliant
■One product for a variety of common through penetrations
■Cost-effective, easy-to-use solution
■Water-based and paintable
■Industry-leading VOC results
■Ethylene glycol-free
12
/
1
6
D
B
S
Order Designation Package Content Item number
FS-ONE MAX 20oz foil (3 case + disp)1x Foil pack dispenser manual CS 270-P1, 75x Firestop sealant FS-ONE MAX 20 oz foil 3530252
FS-ONE MAX 10oz tube (1 case)12x Firestop sealant FS-ONE MAX 10 oz cartridge 3530249
FS-ONE MAX 5 gallon (18 pails)18x Firestop sealant FS-ONE MAX 5 gallon pail 3530263
FS-ONE MAX 20oz foil (1 case)25x Firestop sealant FS-ONE MAX 20 oz foil 3530250
FS-ONE MAX 20oz foil (3 cases)75x Firestop sealant FS-ONE MAX 20 oz foil 3530251
FS-ONE MAX 20oz Foil-Pallet 600x FSONE-MAX 20 oz foil, 290x Bulk Shipping Condition 3534713
FS-ONE MAX 10 oz cartridge 2101531
FS-ONE MAX 5 gallon pail 2101533
Technical data
Chemical basis Water-based acrylic dispersion
Approx. Density 84.3 lb/ft³
Color Red
Application temperature range 41 - 104 °F
Approx. cure time1)4 mm/3 days
Temperature resistance range -4 to 212 °F
Mold and mildew performance Class 0 (ASTM G21-96)
Mold and mildew resistance Yes
Surface burning characteristics
UL 723 (ASTM E84)
Flame spread: 0
Smoke development: 10
Tested in accordance with UL 1479, ASTM E814, ASTM E84,
CAN/ ULC-S115, ASTM G21, ASTM E90
California State fire marshal approval CSFM Listing 4485-1200:0108 for
FS-ONE MAX Intumescent Firestop
Sealant
Expansion ratio (unrestricted, up to)1:5
1) at 75°F/24°C, 50% relative humidity
Mold and mildew
resistant
Chemical
resistant
FILL, VOID OR CAVITY MATERIAL
FOR USE IN THROUGH-PENETRATION
FIRESTOP SYSTEMS
SEE UL FIRE RESISTANCE DIRECTORY
66Y7
05/21/2019
CERTIFICATE OF COMPLIANCE
Certificate Number 20150108-R13240
Report Reference R13240
Issue Date 2015-January-08
William R. Carney, Director, North American Certification Programs
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at www.ul.com/contactus
Page 1 of 1
Issued to: Hilti Construction Chemicals, Div of Hilti Inc.
5400 S 122nd East Ave
Tulsa, OK 74146
This is to certify that
representative samples of
Fill, Void or Cavity Materials
Fill, Void or Cavity Materials Certified for Canada
FS-ONE MAX Intumescent Sealant for use in Through-
Penetration Firestop and Joint Systems in the UL Fire
Resistance Directory and in the Products Certified for
Canada Directory.
Have been investigated by UL in accordance with the
Standard(s) indicated on this Certificate.
Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Through-Penetration
Firestops," – Edition 4
ANSI/UL 2079, "Tests for Fire Resistance of Building Joint
Systems," – Edition 4 – Revision Date 2014/12/17
CAN/ULC-S115, "Standard Method of Fire Tests of Firestop
Systems." – Edition 4 – Issue Date 2011/06/01
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information
Only those products bearing the UL Classification Mark should be considered as being covered by
UL’s Classification and Follow-Up Service.
The UL Classification Mark includes: UL in a circle: with the word “CLASSIFIED” (as shown); a control
number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL’s evaluation of
the product; and the product category name (product identity) as indicated in the appropriate UL
Directory.
Look for the UL Classification Mark on the product.
05/21/2019
FS-ONE MAX; CFS-FIL
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
Date of issue: 07/04/2017 Revision date: 07/04/2017 Supersedes: 12/17/2015 Version: 1.3
05/07/2017 US-OSHA - en 1/7
SECTION 1: Identification
1.1. Identification
Product form Mixture
Name FS-ONE MAX; CFS-FIL
Product code BU Fire Protection
Chemical structure
1.2. Relevant identified uses of the substance or mixture and uses advised against
No additional information available
1.3. Details of the supplier of the safety data sheet
Hilti, Inc.
Legacy Tower, Suite 1000
75024 Plano - USA
T +1 9724035800
1-800-879-8000 toll free - F +1 918 254 0522
Supplier
Hilti, Inc.
Legacy Tower, Suite 1000
75024 Plano - USA
T +1 9724035800
1-800-879-8000 toll free - F +1 918 254 0522
Department issuing data specification sheet
Hilti AG
Feldkircherstraße 100
9494 Schaan - Liechtenstein
T +423 234 2111
chemicals.hse@hilti.com
1.4. Emergency telephone number
Emergency number Chem-Trec
Tel.: 1 800 424 9300 (USA, PR, Virgin Islands, Canada)
Tel.: 703 527 3887 (Other countries)
+1 918 8723000
1-800-879-8000 toll free
SECTION 2: Hazards identification
2.1. Classification of the substance or mixture
GHS-US classification
Not classified
2.2. Label elements
GHS-US labelling
No labelling applicable
2.3. Other hazards
No additional information available
2.4. Unknown acute toxicity (GHS US)
Not applicable
05/21/2019
FS-ONE MAX; CFS-FIL
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
05/07/2017 US-OSHA - en 2/7
SECTION 3: Composition/information on ingredients
3.1. Substance
Not applicable
3.2. Mixture
Name Product identifier % GHS-US classification
Quartz (CAS No) 14808-60-7 2.5 - 5 Carc. 1A, H350
Full text of H-statements: see section 16
SECTION 4: First aid measures
4.1. Description of first aid measures
First-aid measures after inhalation Get medical advice/attention if you feel unwell.
First-aid measures after skin contact Wash skin with plenty of water. If skin irritation occurs: Get medical advice/attention.
First-aid measures after eye contact Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to
do. Continue rinsing. If eye irritation persists: Get medical advice/attention.
First-aid measures after ingestion Get medical advice/attention if you feel unwell.
4.2. Most important symptoms and effects, both acute and delayed
No additional information available
4.3. Indication of any immediate medical attention and special treatment needed
No additional information available
SECTION 5: Firefighting measures
5.1. Extinguishing media
Suitable extinguishing media Water spray. Dry powder. Foam. Carbon dioxide.
5.2. Special hazards arising from the substance or mixture
Reactivity The product is non-reactive under normal conditions of use, storage and transport.
5.3. Advice for firefighters
Protection during firefighting Self-contained breathing apparatus. Complete protective clothing.
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
6.1.1. For non-emergency personnel
No additional information available
6.1.2. For emergency responders
Protective equipment For further information refer to section 8: "Exposure controls/personal protection".
6.2. Environmental precautions
No additional information available
6.3. Methods and material for containment and cleaning up
Methods for cleaning up Mechanically recover the product.
6.4. Reference to other sections
For further information refer to section 13.
05/21/2019
FS-ONE MAX; CFS-FIL
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
05/07/2017 US-OSHA - en 3/7
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Precautions for safe handling Wear personal protective equipment.
Hygiene measures Wash contaminated clothing before reuse. Do not eat, drink or smoke when using this product.
Always wash hands after handling the product.
7.2. Conditions for safe storage, including any incompatibilities
Storage conditions Keep cool. Store in a dry place.
Storage temperature 41 - 77 °F
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
Quartz (14808-60-7)
OSHA Remark (OSHA) (3) See Table Z-3.
Additional information The product has a pasty consistency. Exposure limit values for respirable dusts are not relevant
for this product
8.2. Exposure controls
Personal protective equipment Protective clothing. Safety glasses. Gloves.
Hand protection Protective gloves. EN 374.
Eye protection Chemical goggles or safety glasses.
Skin and body protection Wear suitable protective clothing.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
Physical state Liquid
Appearance Pasty.
Colour red
Odour characteristic
Odour threshold Not determined
pH ≈ 7.85
Melting point Not applicable
Freezing point No data available
Boiling point No data available
Flash point Not applicable
Relative evaporation rate (butylacetate=1) No data available
Flammability (solid, gas) No data available
Explosive limits No data available
Explosive properties No data available
Oxidising properties No data available
Vapour pressure No data available
Relative density No data available
Relative vapour density at 20 °C No data available
05/21/2019
FS-ONE MAX; CFS-FIL
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
05/07/2017 US-OSHA - en 4/7
Density ≈ 1.35 g/cm³
Molecular mass Not determined
Solubility No data available
Log Pow No data available
Auto-ignition temperature No data available
Decomposition temperature No data available
Viscosity No data available
Viscosity, kinematic No data available
Viscosity, dynamic No data available
9.2. Other information
VOC content 9 g/l
SECTION 10: Stability and reactivity
10.1. Reactivity
The product is non-reactive under normal conditions of use, storage and transport.
10.2. Chemical stability
Stable under normal conditions.
10.3. Possibility of hazardous reactions
No dangerous reactions known under normal conditions of use.
10.4. Conditions to avoid
None under recommended storage and handling conditions (see section 7).
10.5. Incompatible materials
No additional information available
10.6. Hazardous decomposition products
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
SECTION 11: Toxicological information
11.1. Information on toxicological effects
Acute toxicity Not classified
Skin corrosion/irritation Not classified
pH: ≈ 7.85
Serious eye damage/irritation Not classified
pH: ≈ 7.85
Respiratory or skin sensitisation Not classified
Germ cell mutagenicity Not classified
Carcinogenicity Not classified
Quartz (14808-60-7)
IARC group 1 - Carcinogenic to humans
Reproductive toxicity Not classified
Specific target organ toxicity (single exposure) Not classified
Specific target organ toxicity (repeated
exposure)
Not classified
05/21/2019
FS-ONE MAX; CFS-FIL
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
05/07/2017 US-OSHA - en 5/7
Aspiration hazard Not classified
SECTION 12: Ecological information
12.1. Toxicity
Ecology - general The product is not considered harmful to aquatic organisms nor to cause long-term adverse
effects in the environment.
12.2. Persistence and degradability
No additional information available
12.3. Bioaccumulative potential
No additional information available
12.4. Mobility in soil
No additional information available
12.5. Other adverse effects
Effect on the global warming No known effects from this product.
SECTION 13: Disposal considerations
13.1. Waste treatment methods
Waste treatment methods Dispose of contents/container in accordance with licensed collector’s sorting instructions.
Waste disposal recommendations Dispose in a safe manner in accordance with local/national regulations.
SECTION 14: Transport information
In accordance with ADR / RID / IMDG / IATA / ADN
ADR IMDG IATA RID
14.1. UN number
Not regulated for transport
14.2. UN proper shipping name
Not applicable Not applicable Not applicable Not applicable
14.3. Transport hazard class(es)
Not applicable Not applicable Not applicable Not applicable
Not applicable Not applicable Not applicable Not applicable
14.4. Packing group
Not applicable Not applicable
Not applicable Not applicable
14.5. Environmental hazards
Dangerous for the environment :
No Dangerous for the environment :
No
Marine pollutant : No
Dangerous for the environment :
No Dangerous for the environment :
No
No supplementary information available
05/21/2019
FS-ONE MAX; CFS-FIL
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
05/07/2017 US-OSHA - en 6/7
14.6. Special precautions for user
- Overland transport
- Transport by sea
No data available
- Air transport
No data available
- Rail transport
Carriage prohibited (RID) No
14.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
SECTION 15: Regulatory information
15.1. US Federal regulations
All components of this product are listed, or excluded from listing, on the United States Environmental Protection Agency Toxic Substances
Control Act (TSCA) inventory
15.2. International regulations
CANADA
FS-ONE MAX; CFS-FIL
WHMIS Classification Uncontrolled product according to WHMIS classification criteria
EU-Regulations
No additional information available
Classification according to Regulation (EC) No. 1272/2008 [CLP]
Not classified
National regulations
Quartz (14808-60-7)
Listed on IARC (International Agency for Research on Cancer)
15.3. US State regulations
California Proposition 65 - This product does not contain any substances known to the state of California to cause
cancer, developmental and/or reproductive harm
SECTION 16: Other information
Revision date 07/04/2017
Full text of H-statements:
------ H350 May cause cancer
05/21/2019
FS-ONE MAX; CFS-FIL
Safety Data Sheet
according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations
05/07/2017 US-OSHA - en 7/7
NFPA health hazard 0 - Materials that, under emergency conditions, would offer
no hazard beyond that of ordinary combustible materials.
NFPA fire hazard 0 - Materials that will not burn under typical dire conditions,
including intrinsically noncombustible materials such as
concrete, stone, and sand.
NFPA reactivity 0 - Material that in themselves are normally stable, even
under fire conditions.
Hazard Rating
Health 0 Minimal Hazard - No significant risk to health
Flammability 0 Minimal Hazard - Materials that will not burn
Physical 0 Minimal Hazard - Materials that are normally stable, even under fire conditions, and will NOT
react with water, polymerize, decompose, condense, or self-react. Non-Explosives.
Personal protection B
B - Safety glasses, Gloves
SDS_US_Hilti
This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and
environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product
05/21/2019
Hilti, Inc.
5400 South 122nd East Avenue
Tulsa, OK 74146
1 -800-879-8000
www.hilti.com
August 26, 2015
To Whom It May Concern:
Re: Hilti FS-ONE Max Firestop – LEED Info.
Item Numbers:
2101531
2101532
2101533
The Hilti FS-ONE MAX Firestop is manufactured in the United States
There is no post-consumer or post-industrial content in FS-ONE MAX and it cannot be recycled. The VOC content for FS-ONE
MAX is 9 grams/liter.
FS-ONE MAX is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-
regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and
state regulatory agencies for direction on disposal.
Please feel free to contact me at (918) 872-3704 if you have questions.
Sincerely,
Jerry Metcalf MPH, CHMM
Sr. Manager, Safety/Environmental
Hilti Inc
(918) 872 3704
jerry.metcalf@hilti.com
Rev. Date: 7/31/15
The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.
The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.
Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.
05/21/2019
Thermafiber® Safing™Fire Containment Insulation
Exceptional performance in Perimeter
Fire Containment Systems
Provides life saving fire protection in
rated assemblies
Fire resistant to temperatures above
2,000°F (1,093°C)
Easy to fabricate for through
penetrations and firestopping
Conserves energy, reduces
greenhouse gas emissions
Resists moisture
Controls noise and sound
+
+
+
+
+
+
+
Thermafiber Safing and FireSpan® insulation provide the critical components of
the perimeter fire containment system in the 111 South Wacker Building in Chicago,
IL. Thermafiber insulation also contributed to the building’s LEED® Gold Rating.
Thermafiber® SafingTM is compression fitted between FireSpan® insulation and
the concrete slab edge to create a perimeter fire containment system.
LEED® v2009 Green Building Credits
Energy &
Atmosphere
Materials
& Resources
Indoor
Environmental
Quality
Innovation in
Design
1 2.1, 2.2 9 1
4.1, 4.2
5.1, 5.2
Minimum70%
Recycled
Content1
05/21/2019
Thermafiber® SafingTM Insulation
Description:
Thermafiber® Insolutions®:
For Further Information:
Notice:
Submittal Approvals:
THERMAFIBER SafingTM products are designed to provide life saving fire protection in perimeter fire containment
systems, floor and wall penetrations, construction joints, and other firestopping applications. These products are
noncombustible, moisture-resistant, noncorrosive, nondeteriorating, mildew-proof and vermin-proof. Thermafiber Safing
provides thermal insulation, fire protection, and acoustical control in many different UL and Intertek (formerly OPL) listed
fire containment assemblies of 1, 2, and 3-hr ratings.
Thermafiber offers industry leading technical and engineering assistance to architects, specifiers, and contractors.
These services include CAD drawings, engineering judgments, LEED® Credit Information, product recommendations,
and customized products. Contact our technical services department at
1-888-834-2371, or email technicalservice@owenscorning.com
For additional information about these or other Thermafiber products contact us at 1-888-834-2371 or visit our
website www.thermafiber.com.
THERMAFIBER, Inc. shall not be liable for incidental and consequential damages, directly or indirectly sustained, nor for any loss caused by application of
these goods not in accordance with current printed instructions or for other than the intended use. THERMAFIBER liability is expressly limited to replacement of
defective goods. Any claim shall be deemed waived unless made in writing within thirty (30) days from date it was or reasonably should have been discovered.
Job Name
Contractor Date
3711 Mill Street | Wabash, IN 46992 | 888-TFIBER1 [834-2371] | [260] 563-2111 | www.thermafiber.com
Standard Sizes:
Standards Compliance:SafingTM Insulation meets the following:
ASTM C 665 Non-corrosive, Type I, III
ASTM C 612 Type IA, IB, II
ASTM E 136 Rated Non-combustible per NFPA Standard 220
CAN/ULC S114 Complies
ASTM E 96 Unfaced, 50 Perms as tested
ASTM E 96 Foil Faced, 0.02 Perms as tested
ASTM C 1104 Absorbs less than 1% by volume
CAN/ULC S102 Flame Spread 0, Smoke Developed 0
ASTM E 814 or UL 1479 Safing Insulation used in conjunction with an approved fill, void, or cavity material
sealant or other approved material in through – penetration firestop systems - Complies
UL 2079 Safing Insulation used in conjunction with an approved fill, void or cavity material
in construction joint systems - Complies
CAN/ULC S115 Complies
Safing products are approved by: New York City Board of Standards & Appeals – (under BSA 39-74-SM & accepted by
MEA-209-82-M, Vol. 4).
Thickness* Widths** Lengths**
Safing 4.0 pcf 1”- 7” 16”, 24”, 36” 48”, 60”
Safing 6.0 pcf 1”- 7” 16”, 24”, 36” 48”, 60”
Tolerances +1/4” - 1/8” ±1/8” ±1/2”
*Thicknesses are available in ½” increments. **Custom sizes are available upon request.
Product Options:• Safing 4.0 pcf, 2” or greater thickness, is available with or without a vapor retarding foil facing.
• Safing 6.0 pcf, 1.5” or greater thickness, is available with or without a vapor retarding foil facing.
• Recycled Content Options1:
EPA Choice Fiber (US Government Buildings) ........Minimum 75%
Standard Fiber ....................................................................70% 1Recycled content options other than Standard must be specified at time of order.
Installation:All firestopping insulation should be installed per the architectural specification or system specific test description. All
compressed Safing insulation should be installed per the listed assembly.
• Perimeter Installation: SafingTM insulation should be compression fitted between the slab edge and the FireSpan
curtain wall insulation, leaving no voids.
• Penetration Application: Safing insulation should be cut slightly larger than the opening and compression fitted into the
opening, leaving no voids.
• Construction Joint Application: Safing insulation should be compression fitted into the joint opening, leaving no voids.
Technical Data:
TF
6
1
2
/
R
e
v
0
3
-
1
5
C
o
p
y
r
i
g
h
t
2
0
1
5
,
T
h
e
r
m
a
f
i
b
e
r
,
I
n
c
.
Al
l
R
i
g
h
t
s
R
e
s
e
r
v
e
d
.
L
E
E
D
®
is
a
r
e
g
i
s
t
e
r
e
d
t
r
a
d
e
m
a
r
k
o
f
U
.
S
.
G
r
e
e
n
B
u
i
l
d
i
n
g
C
o
u
n
c
i
l
.
SafingTM insulation is a critical component of any perimeter fire containment system. Thermafiber® has performed decades
of testing in all of the containment systems listed below. For more complete test information, see SA707, THERMAFIBER
Life-Safety Fire Containment Systems technical catalog or UL® and Intertek® (formerly OPL) Directories. For a full listing of
containment systems visit www.thermafiber.com and click on Fire Rated Assemblies. UL Reference = TYPE SAF
• Aluminum Spandrel Curtain Wall Fire Containment
• Steel Stud-Framed/Gypsum Sheathing Curtain Wall Fire Containment
• Glass Spandrel Curtain Wall Fire Containment
• Granite Spandrel Curtain Wall Fire Containment
• Precast Concrete Spandrel
Fire-Containment Tests
Per ASTM E 2307
Product Actual “k” @ 75° [24°C] “R” value per
Designation Density inch of thickness***
Safing 4.0 pcf 0.24 ‘R’= 4.2 0 0 25 0
Safing 6.0 pcf 0.24 ‘R’= 4.2 0 0 25 0
BTU.in/hr.sq. ft. °F
Tested to ASTM C 518
Tested to ASTM E 84
Unfaced Foil Faced
Flame
Spread
Flame
Spread
Smoke
Developed
Smoke
Developed
***R = thickness divided by ‘k’
05/21/2019
CERTIFICATE OF COMPLIANCE
Certificate Number 20151218-R10905
Report Reference R10905
Issue Date 2015-December-18
Bruce Mahrenholz, Director North American Certification Program
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 3
Issued to: Thermafiber Inc.
3711 Mill St
Wabash, IN 46992 USA
This is to certify that
representative samples of
Forming Materials
Forming Materials Certified for Canada
Have been investigated by UL in accordance with the
Standard(s) indicated on this Certificate.
Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Through-Penetration Firestops,"
ANSI/UL 2079, "Tests for Fire Resistance of Building Joint
Systems," and ANSI/ASTM E2307 (2010), "Standard Test
Method for Determining Fire Resistance of Perimeter Fire
Barriers Using Intermediate-Scale, Multi-story Test Apparatus."
CAN/ULC-S115 (2005), "Standard Method of Fire Tests of
Firestop Systems."
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information
Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.
Look for the UL Certification Mark on the product.
05/21/2019
CERTIFICATE OF COMPLIANCE
Certificate Number 20151218-R10905
Report Reference R10905
Issue Date 2015-December-18
Bruce Mahrenholz, Director North American Certification Program
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 2 of 3
This is to certify that representative samples of the product as specified on this certificate were tested according to the
current UL requirements.
Type SAF mineral wool batts for use in Joint System Nos. BW-S-0029, FF-D-0002, FF-D-0011, FF-D-0013,
FF-D-0014, FF-D-0015, FF-D-0016, FF-D-0017, FF-D-0019, FF-D-0022, FF-D-0023, FF-D-0025, FF-D-0026,
FF-D-0028, FF-D-0073, FF-D-0074, FF-D-0096, FF-D-0097, FF-D-0109, FF-D-1001, FF-D-1002, FF-D-1003,
FF-D-1004, FF-D-1006, FF-D-1007, FF-D-1008, FF-D-1010, FF-D-1015, FF-D-1016, FF-D-1020, FF-D-1021,
FF-D-1024, FF-D-1025, FF-D-1027, FF-D-1036, FF-D-1039, FF-D-1040, FF-D-1041, FF-D-1042, FF-D-1045,
FF-D-1047, FF-D-1098, FF-D-1125, FF-D-1158, FF-D-3003, FF-D-3004, FF-S-1031, FF-S-1033, FW-D-0001,
FW-D-0004, FW-D-0007, FW-D-0009, FW-D-0010, FW-D-0011, FW-D-0012, FW-D-0014, FW-D-0017, FW-D-0018,
FW-D-0020, FW-D-0021, FW-D-0023, FW-D-0024, FW-D-0027, FW-D-0050, FW-D-0051, FW-D-0067, FW-D-0068,
FW-D-1001, FW-D-1002, FW-D-1003, FW-D-1005, FW-D-1006, FW-D-1007, FW-D-1009, FW-D-1010, FW-D-1016,
FW-D-1017, FW-D-1020, FW-D-1024, FW-D-1033, FW-D-1035, FW-D-1037, FW-D-1038, FW-D-1039, FW-D-1040,
FW-D-1044, FW-D-1047, FW-D-1055, FW-D-1070, FW-D-1089, FW-D-1092, FW-D-1093, FW-D-1102, FW-D-1103
FW-S-1016, FW-S-1019, HW-D-0001, HW-D-0002, HW-D-0006, HW-D-0009, HW-D-0013, HW-D-0016, HW-D-0017,
HW-D-0020, HW-D-0021, HW-D-0022, HW-D-0023, HW-D-0025, HW-D-0026, HW-D-0027, HW-D-0028, HW-D-0029,
HW-D-0030, HW-D-0031, HW-D-0034, HW-D-0038, HW-D-0039, HW-D-0040, HW-D-0042, HW-D-0043, HW-D-0044,
HW-D-0045, HW-D-0046, HW-D-0047, HW-D-0049, HW-D-0050, HW-D-0051, HW-D-0052, HW-D-0054,
HW-D-0055, HW-D-0058, HW-D-0059, HW-D-0062, HW-D-0064, HW-D-0067, HW-D-0069, HW-D-0072,
HW-D-0073, HW-D-0075, HW-D-0079, HW-D-0086, HW-D-0087, HW-D-0088, HW-D-0089, HW-D-0091,
HW-D-0092, HW-D-0099, HW-D-0100, HW-D-0101, HW-D-0102, HW-D-0103, HW-D-0104, HW-D-0105,
HW-D-0106, HW-D-0107, HW-D-0108, HW-D-0118, HW-D-0122, HW-D-0123, HW-D-0127, HW-D-0128,
HW-D-0131, HW-D-0136, HW-D-0137, HW-D-0139, HW-D-0140, HW-D-0143, HW-D-0146, HW-D-0149,
HW-D-0152, HW-D-0153, HW-D-0154, HW-D-0156, HW-D-0157, HW-D-0160, HW-D-0166, HW-D-0168,
HW-D-0170, HW-D-0171, HW-D-0172, HW-D-0173, HW-D-0174, HW-D-0177, HW-D-0178, HW-D-0185,
HW-D-0186, HW-D-0187, HW-D-0188, HW-D-0190, HW-D-0192, HW-D-0199, HW-D-0200, HW-D-0201,
HW-D-0204, HW-D-0205, HW-D-0206, HW-D-0208, HW-D-0211, HW-D-0218, HW-D-0220, HW-D-0221,
HW-D-0222, HW-D-0246, HW-D-0248, HW-D-0252, HW-D-0253, HW-D-0258, HW-D-0259, HW-D-0263,
HW-D-0265, HW-D-0278, HW-D-0279, HW-D-0297, HW-D-0298, HW-D-0299, HW-D-0335, HW-D-0336,
HW-D-0337, HW-D-0338, HW-D-0354, HW-D-0357, HW-D-0358, HW-D-0359, HW-D-0363, HW-D-0365,
HW-D-0366, HW-D-0367, HW-D-0377, HW-D-0378, HW-D-0380, HW-D-0381, HW-D-0384, HW-D-0385,
HW-D-0388, HW-D-0389, HW-D-0391, HW-D-0395, HW-D-0396, HW-D-0404, HW-D-0405, HW-D-0406,
HW-D-0407, HW-D-0408, HW-D-0409, HW-D-0410, HW-D-0411, HW-D-0412, HW-D-0413, HW-D-0414,
HW-D-0415, HW-D-0416, HW-D-0417, HW-D-0441, HW-D-0442, HW-D-0447, HW-D-0456, HW-D-0457,
HW-D-0460, HW-D-0465, HW-D-0467, HW-D-0468, HW-D-0478, HW-D-0479, HW-D-0524, HW-D-0531,
HW-D-0536, HW-D-0538, HW-D-0539, HW-D-0540, HW-D-0542, HW-D-0546, HW-D-0547, HW-D-0548,
HW-D-0549, HW-D-0553, HW-D-0560, HW-D-0561, HW-D-0562, HW-D-0564, HW-D-0566, HW-D-0567,
HW-D-0568, HW-D-0569, HW-D-0570, HW-D-0571, HW-D-0572, HW-D-0577, HW-D-0578, HW-D-0580,
05/21/2019
CERTIFICATE OF COMPLIANCE
Certificate Number 20151218-R10905
Report Reference R10905
Issue Date 2015-December-18
Bruce Mahrenholz, Director North American Certification Program
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 3 of 3
Type SAF mineral wool batts for use in Joint System Nos. HW-D-0582, HW-D-0583, HW-D-0584, HW-D-0590,
HW-D-0591, HW-D-0597, HW-D-0612, HW-D-0614, HW-D-0617, HW-D-0619, HW-D-0631, HW-D-0633,
HW-D-0634, HW-D-0635, HW-D-0636, HW-D-0639, HW-D-0640, HW-D-0642, HW-D-0643, HW-D-0644,
HW-D-0645, HW-D-0649, HW-D-0650, HW-D-0661, HW-D-0662, HW-D-0687, HW-D-0697, HW-D-0698,
HW-D-0702, HW-D-0703, HW-D-0704, HW-D-0725, HW-D-0726, HW-D-0735, HW-D-0740, HW-D-0741,
HW-D-0742, HW-D-0743, HW-D-0747, HW-D-0748, HW-D-0750, HW-D-1001, HW-D-1002, HW-D-1003,
HW-D-1004, HW-D-1005, HW-D-1006, HW-D-1007, HW-D-1010, HW-D-1013, HW-D-1014, HW-D-1015,
HW-D-1016, HW-D-1020, HW-D-1021, HW-D-1022, HW-D-1023, HW-D-1024, HW-D-1028, HW-D-1032,
HW-D-1033, HW-D-1034, HW-D-1037, HW-D-1040, HW-D-1042, HW-D-1044, HW-D-1045, HW-D-1050,
HW-D-1060, HW-D-1066, HW-D-1067, HW-D-1068, HW-D-1069, HW-D-1070, HW-D-1073, HW-D-1074,
HW-D-1075, HW-D-1076, HW-D-1077, HW-D-1079, HW-D-1080, HW-D-1089, HW-D-1094, HW-D-1097,
HW-D-1102, HW-D-1103, HW-D-1104, HW-D-1110, HW-S-0001, HW-S-0009, HW-S-0010, HW-S-0053,
HW-S-0054, HW-S-0080, HW-S-0083, HW-S-1015, WW-D-0013, WW-D-0018, WW-D-0019, WW-D-0020,
WW-D-0063, WW-D-1001, WW-D-1002, WW-D-0022, WW-D-0089, WW-D-0090, WW-D-0103, WW-D-0171,
WW-D-0140, WW-D-0141, WW-D-1003, WW-D-1004, WW-D-1005, WW-D-1006, WW-D-1007, WW-D-1010,
WW-D-1015, WW-D-1016, WW-D-1023, WW-D-1027, WW-D-1036, WW-D-1037, WW-D-1042, WW-D-1047,
WW-D-1089, WW-D-1090, WW-D-1091, WW-D-1128, WW-D-1129, WW-S-0064, WW-S-1035.
TYPE SAF MINERAL WOOL BATTS FOR USE IN PERIMETER FIRE CONTAINMENT SYSTEM NOS. CW-D-1001, CW-D-1002,
CW-D-1003, CW-D-1004, CW-D-1005, CW-D-1006, CW-D-1007, CW-D-1008, CW-D-1009, CW-D-1010,
CW-D-1011, CW-D-1012, CW-D-1013, CW-D-1014, CW-D-1015, CW-D-1016, CW-D-1017, CW-D-1018,
CW-D-1019, CW-D-1020, CW-D-1021, CW-D-1022, CW-D-1023, CW-D-1028, CW-D-1029, CW-D-1030,
CW-D-2001, CW-D-2002, CW-D-2003, CW-D-2005, CW-D-2006, CW-D-2008, CW-D-2009, CW-D-2010,
CW-D-2011, CW-D-2012, CW-D-2013, CW-D-2036, CW-D-2037, CW-D-2038, CW-D-2039, CW-D-2040,
CW-D-2041, CW-D-2042, CW-D-2046, CW-D-2047, CW-D-2048, CW-D-2049, CW-D-2050, CW-D-2051,
CW-D-2052, CW-D-2055, CW-D-2056, CW-D-2057, CW-D-2058, CW-D-2059, CW-D-2063, CW-D-2064,
CW-D-2065, CW-D-2066, CW-S-0001, CW-S-0002, CW-S-0003, CW-S-0004, CW-S-1001, CW-S-1002,
CW-S-1003, CW-S-1007, CW-S-1010, CW-S-1016, CW-S-1017, CW-S-1020, CW-S-1022, CW-S-1023,
CW-S-1024, CW-S-1025, CW-S-1026, CW-S-2001, CW-S-2002, CW-S-2003, CW-S-2006, CW-S-2008,
CW-S-2014, CW-S-2021, CW-S-2022, CW-S-2023, CW-S-2025, CW-S-2029, CW-S-2034, CW-S-2035,
CW-S-2036, CW-S-2058, CW-S-2059, CW-S-2060, CW-S-2061, CW-S-2062, CW-S-2064, CW-S-2065,
CW-S-2066.
TYPE SAF MINERAL WOOL BATTS FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEM NOS. C-AJ-1020, C-AJ-1081,
C-AJ-3045, W-L-1027, W-L-1039, W-L-1064, W-L-1065, W-L-2023, W-L-2036, W-L-3023, W-L-3034, W-L-7001,
W-L-7002.
TOPSTOP MINERAL WOOL DECK PLUGS TYPE SAF BATTS FOR USE IN JOINT SYSTEM NOS. HW-D-0001, HW-D-0002,
HW-D-0020, HW-D-0022, HW-D-0034, HW-D-0039, HW-D-0043, HW-D-0086, HW-D-0088, HW-D-0160,
HW-D-0161, HW-D-0456, HW-D-0612, HW-D-0644.
05/21/2019
Hilti, Inc.
5400 South 122nd East Avenue
Tulsa, OK 74146
1-800-879-8000
www.hilti.com
September 24, 2015
To Whom It May Concern:
Re: Hilti Mineral Wool-LEED Information
Item Number:
236993
The Hilti Mineral Wool is manufactured in Wabash, Indiana.
The post-consumer recycled content in the Hilti Mineral Wool is 0%. The pre-consumer recycled content in the Hilti Mineral Wool
is 90%. There is no detectable VOC content in this product.
Hilti Mineral Wool is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-
regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and
state regulatory agencies for direction on disposal.
Please feel free to contact me at (918) 872-3704 if you have questions.
Sincerely,
Jerry Metcalf MPH, CHMM
Sr. Manager, Safety/Environmental
Hilti Inc.
918 872 3704
jerry.metcalf@hilti.com
Rev. Date: 9/24/15
The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used
for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America
requirements, as those requirements differ.
The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced
non-catalog Hilti products may have differing manufacturing plant locations.
Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates.
05/21/2019