Loading...
HomeMy WebLinkAboutFile Documents.747 S Galena St.0122.2019 (17).ARBKTable Of Contents UL Listings C-AJ-1291 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 C-AJ-1346 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 C-AJ-2109 (US Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 F-A-2075 (US Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 F-A-2093 (US Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 W-L-1410 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 W-L-2128 (US Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 W-L-3065 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 W-L-5028 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 W-L-5029 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 CP 606 Firestop acrylic sealant Product Data Sheet for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 UL Certificate of Compliance for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Safety Data Sheet (SDS) for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 LEED Information for CP 606 Flexible Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 CP 643 N firestop collars Product Data Sheet for CP 643N Firestop Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 UL Certificate of Compliance for CP 643N Firestop Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Safety Data Sheet (SDS) for CP 643N, CP 644 Firestop Collar and CP 648-S, CP 648-E Firestop Wrap Strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 LEED Information for CP 643N and CP 644 Firestop Collars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 CP 644 Firestop collars US Product Data Sheet for CP 644 Firestop Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 UL Certificate of Compliance for CP 644 Firestop Collar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Safety Data Sheet (SDS) for CP 643N, CP 644 Firestop Collar and CP 648-S, CP 648-E Firestop Wrap Strip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 LEED Information for CP 643N and CP 644 Firestop Collars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 FS-ONE MAX Firestop intumescent sealant Product Data Sheet for FS-ONE MAX Intumescent Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . 41 UL Certificate of Compliance for FS-ONE MAX Intumescent Firestop Sealant . . . . . . . . . . . . . . . . . . 42 Safety Data Sheet (SDS) for FS-ONE MAX Intumescent Firestop Sealant . . . . . . . . . . . . . . . . . . . . 43 LEED Information for FS-ONE MAX Intumescent Firestop Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Mineral wool Product Data Sheet for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 UL Certificate of Compliance for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 LEED Information for Mineral Wool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 05/21/2019 05/21/2019 System No. C-AJ-1346 SECTION A-A CA J 1 3 4 6 )ORRURU:DOO$VVHPEO\²0LQLQ PP WKLFNUHLQIRUFHGOLJKWZHLJKWRUQRUPDOZHLJKW SFIRUNJP FRQFUHWH:DOO may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 3 in. (76 mm). See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 7KURXJK3HQHWUDQW²0D[RQHIOH[LEOHPHWDOSLSHRUFRQGXLWLQVWDOOHGFRQFHQWULFDOO\RUHFFHQWULFDOO\ZLWKLQRSHQLQJ7KHDQQXODUVSDFHEHWZHHQ penetrant and periphery of opening shall be min of 1/2 in. (13 mm) to max 1-1/4 in. (32 mm). Penetrant to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of penetrants may be used: $)OH[LEOH6WHHO&RQGXLW²1RPLQ PP GLDP RUVPDOOHU IOH[LEOHVWHHOFRQGXLW See Flexible Metal Conduit (DXUZ) category in the Electrical Construction Material Directory for names of manufacturers. %7KURXJK3HQHWUDWLQJ3URGXFW ²)OH[LEOH0HWDO3LSLQJ²7KHIROORZLQJW\SHVRIVWHHOIOH[LEOHPHWDOJDVSLSLQJPD\EHXVHG 1. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. OMEGA FLEX INC 2. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. GASTITE, DIV OF TITEFLEX 3. Nom 1 in. (25 mm) diam (or smaller) steel flexible metal gas piping. Plastic covering on piping may or may not be removed on both sides of floor or wall assembly. WARD MFG L L C )LUHVWRS6\VWHP²7KHILUHVWRSV\VWHPVKDOOFRQVLVWRIWKHIROORZLQJ $3DFNLQJ0DWHULDO²0LQLQ PP WKLFNQHVVRIPLQSFI NJP PLQHUDOZRROEDWWLQVXODWLRQILUPO\SDFNHGLQWRWKHRSHQLQJDVD permanent form. Packing material to be recessed from top surface of floor or both surfaces of wall to accommodate the required thickness of fill material. %)LOO9RLGRU&DYLW\0DWHULDOV ²6HDODQW²0LQLQ PP WKLFNQHVVRIVHDODQWDSSOLHGZLWKLQDQQXODUVSDFHIOXVKZLWKWRSVXUIDFHRI floor or both surfaces of wall. +,/7,&216758&7,21&+(0,&$/6',92)+,/7,,1&²)621(6HDODQWRU)621(0$;,QWXPHVFHQW6HDODQW * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. +Bearing the UL Listing Mark A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 08, 2015 A 1A 1B 3B 3A2 3B 2 C CL A S S IFI E D Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US ANSI/ UL1479 (ASTM E814)CAN/ULC S115 F Rating - 2 Hr F Rating - 2 Hr T Rating - 0 Hr FT Rating - 0 Hr FH Rating - 2 Hr FTH Rating - 0 Hr 05/21/2019 Hilti Firestop Systems System No. C-AJ-2109 SECTION A-A CA J 2 1 0 9 Page: 1 of 2 1. Floor or Wall Assembly — Min 4-1/2 in. (114 mm) thick reinforced lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 12 in. (305 mm). See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufactures. 2. Steel Sleeve — (Optional) — Nom 12 in. (305 mm) diam (or smaller) Schedule 40 (or heavier) steel pipe cast or grouted into floor or wall assembly, flush with floor or wall surfaces a max of 3 in. (76 mm) above the floor. If the steel sleeve extends above the floor, the T Rating of the firestop system is 0 Hr and a min 1/2 in. (13 mm) annular space is required between the through penetrant (Item 3) and the periphery of the opening. The W Rating does not apply when the steel sleeve is used. 3. Through Penetrants — One nonmetallic pipe to be installed either concentrically or eccentrically within the firestop system. For max 6 in. (152 mm) diam pipes, the annular space between the pipe and the periphery of opening shall be min 0 in. (0 mm, point contact) to max 1/2 in. (13 mm). For nom 8 in. (203 mm) and 10 in. (254 mm) diam pipes, the annular space between the pipe and the periphery of opening shall be min 0 in. (0 mm, point contact) to max 1-1/4 in. (32 mm). If the steel sleeve extends above the floor (Item 2), a min 1/2 in. (13 mm) annular space is required between the through penetrant (Item 3) and the periphery of the opening. Pipe to be rigidly supported on both sides of floor or wall assembly. For systems with a W Rating, the max annular space is 1/2 in. (13 mm). The T Ratings are dependent on the size and/or type of pipe as shown in the table below. The following types and sizes of nonmetallic pipes may be used: A. Polyvinyl Chloride (PVC) Pipe — Nom 10 in. (254 mm) diam (or smaller) Schedule 40 solid core or cellular core PVC pipe for use in closed (process or supply ) or vented (drain, waste or vent) piping systems. For systems with a W Rating, the nom diam of pipe shall not exceed 6 in. (152 mm). B. Chlorinated Polyvinyl Chloride (CPVC) Pipe — Nom 10 in. (254 mm) diam (or smaller) SDR13.5 CPVC pipe for use in closed (process or supply) piping systems. For systems with a W Rating, the nom diam of pipe shall not exceed 6 in. (152 mm). C. Acrylonitrile Butadiene Styrene (ABS) Pipe — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 solid-core or cellular core ABS pipe for use in closed (process or supply) or vented (drain, waste or vent) piping system. D. Flame Retardant Polypropylene (FRPP) Pipe — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 FRPP pipe for use in closed (process or supply) or vented (drain, waste or vent) piping systems. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. July 31, 2018 )5DWLQJV³DQG+U 6HH,WHP 75DWLQJV³DQG+U 6HH,WHPVDQG W Rating - Class 1 (See Items 2, 3 and 4) /5DWLQJDW$PELHQW³/HVV7KDQ&)0VTIW 6HH,WHP /5DWLQJDW)³/HVV7KDQ&)0VTIW 6HH,WHP A A 3 2 5 4 5 4 2 1 3 CL A S S IFI E D Classified by Underwriters Laboratories, Inc. to UL 1479 05/21/2019 Page: 2 of 2 + Indicates solid core ABS only. ++ Indicates cellular core ABS only. 4. Fill, Void or Cavity Material* — Sealant — Min 1/2 in. (13 mm) thickness of fill material applied within the annulus, flush with top or bottom surface of floor or both surfaces of wall. Sealant is optional for pipes having a max diam of 6 in. (152 mm) in unsleeved openings. For systems with W Rating and/or L Rating, min 1/2 in. (13 mm) thickness of CP 601S, CFS-S SIL GG, CFS-S SIL SL (floors only) Sealant shall be applied within the annulus, flush with top or bottom surface of floor. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-ONE MAX Intumescent Sealant, CP 601S Sealant, CFS-S SIL GG, CFS-S SIL SL (floors only) Sealant 4A. Packing Material — (Not Shown) — Min 1/2 in. (13 mm) thickness of 4 pcf (64 kg/m3) mineral wool batt insulation firmly packed into annular space and recessed from the top surface of floor to accommodate the required thickness of fill material. Required only when CP 604 Sealant is used. 5. Firestop Device* — Firestop Collar — Firestop collar shall be installed in accordance with the accompanying installation instructions. Collar to be installed and latched around the pipe and secured to underside of floor or both sides of wall using the anchor hooks provided with the collar. Minimum two anchor hooks for nom 1-1/2 and 2 in. (38 and 51 mm) diam pipes. Minimum three anchor hooks required for nom 3 and 4 in. (76 and 102 mm) diam pipes. Minimum four anchor hooks required for nom 6 in. (152 mm) diam pipes. Minimum ten anchor hooks required for nom 8 in (203 mm) diam pipes. Minimum twelve anchor hooks required for nom 10 in. (254 mm) diam pipes. The anchor hooks are to be secured with min 1/4 in. (6 mm) diam by min 1-1/4 in. (32 mm) long steel expansion bolts or min 0.145 in. (3.7 mm) diam by 1-1/4 in. (32 mm) long powder actuated fasteners utilizing a 1-7/16 in. (37 mm) diam by 1/16 in. (1.6 mm) thick steel washer. As alternates to the anchors specified above, Hilti 1/4 in. (6 mm) diam by 1-1/4 in. (32 mm) long KWIK-CON II+ concrete screw anchor, Hilti 1/4 in. (6 mm) diam by 1-3/4 in. (45 mm) long KWIK-BOLT 3 steel expansion anchor or Hilti X-DNI 27 P8 S15 powder actuated floor pin with integral nom 9/16 in. (15 mm) diam washer may be used. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP 643N 50/1.5", CP 643N 63/2", CP 643N 90/3", CP 643N 110/4", CP 643 160/6", CP 644-200/8" US or CP 644-250/10" US Firestop Collar * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. Hilti Firestop Systems CA J 2 1 0 9 Pipe Type Nom Pipe Diam, In. (mm) F Rating Hr PVC, CPVC Greater than 6 (152)2 PVC, CPVC, ABS, FRPP 6 (152) or smaller 3 Pipe Type Nom Pipe Diam, In. (mm) T Rating Hr PVC, CPVC, ABS, FRPP 1-1/2, 2, 3 (38, 51, 76)2 PVC, CPVC, ABS, FRPP 4 (102)3 PVC, CPVC, ABS+, FRPP 6 (152)3 PVC, CPVC Greater than 6 (152)0 ABS++6 (152)0 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. July 31, 2018 System No. C-AJ-2109 05/21/2019 05/21/2019 05/21/2019 05/21/2019 05/21/2019 System No. W-L-3065 SECTION A-A WL 3 0 6 5 Page: 1 of 2 1. Wall Assembly — The 1 or 2 fire-rated gypsum wallboard/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC. B. Gypsum Board* — Nom 5/8 in. (16 mm) thick gypsum board, with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design in the UL Fire Resistance Directory. Max diam of opening is 5-1/2 in. (138 mm) when sleeve (Item 2) is employed. Max diam of opening is 4 in. (102 mm) when sleeve (Item 2) is not employed. The F, FH Ratings of the firestop system are equal to the fire rating of the wall assembly. 2. Metallic Sleeve — (Optional) - Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT) or Schedule 5 (or heavier) steel pipe or min 0.016 in. thick (0.41 mm, No. 28 ga) galv steel sleeve installed flush with wall surfaces. The annular space between steel sleeve and periphery of opening shall be min 0 in. (0 mm, point contact) to max 1 in. (25mm). When Schedule 5 steel pipe or EMT is used, sleeve may extend up to 18 in. (457 mm) beyond the wall surfaces. As an option when Schedule 5 steel pipe or EMT is used, sleeve may extend continuously beyond one wall surface. When cable bundle penetrates wall assembly at an angle of 45 degrees, no metallic sleeve is used. Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. October 14, 2015 A A 2 3 4 1B Hilti Firestop Systems 2 1A C CL A S S IFI E D Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US ANSI/UL1479 (ASTM E814)CAN/ULC S115 F Rating — 1 and 2 Hr (See Item 1)F Rating — 1 and 2 Hr (See Item 1) T Rating — 0 and 3/4 Hr (See item 3)FT Rating — 0 and 3/4 Hr (See item 3) L Rating At Ambient — 15 CFM/sq ft FH Rating — 1 and 2 Hr (See Item 1) L Rating At 400 F — 8 CFM/sq ft FTH Rating — 0 and 3/4 Hr (See item 3) L Rating At Ambient — 15 CFM/sq ft L Rating At 400 F — 8 CFM/sq ft 05/21/2019 Page: 2 of 2 3. Cables — Aggregate cross-sectional area of cable in opening to be max 45 percent of the cross-sectional area of the opening. The annular space between the cable bundle and the periphery of the opening to be min 0 in. (point contact) to max 1 in. (25 mm). When sleeve is continuous on one side of wall (see Item 2), the cable fill may be 0 to 45% and the max annular space is not limited. Cables to be rigidly supported on both sides of the wall assembly. Any combination of the following types and sizes of copper conductor cables may be used: A. Max 7/C No. 12 AWG with polyvinyl chloride (PVC) insulation and jacket. B. Max 25 pair No. 24 AWG telephone cable with PVC insulation and jacket. B1. Max 4 pr No. 22 AWG Cat 5 or Cat 6 computer cables. C. Type RG/U coaxial cable with polyethylene (PE) insulation and PVC jacket having a max outside diameter of ½ in. (13 mm). C1. Max RG 6/U coaxial cable with fluorinated ethylene insulation and jacketing. D. Multiple fiber optical communication cable jacketed with PVC and having a max OD of 5/8 in. (16 mm). E. Through Penetrating Products*— Max three copper conductor No. 8 AWG .Metal-Clad Cable+. AFC CABLE SYSTEMS INC F. Max 3/C (with ground)(or smaller) No. 8 AWG copper conductor cable with PVC insulation and jacketing. G. Max 3/4 in. (19 mm) diam copper ground cable with or without a PVC jacket. H. Fire Resistive Cables* - Max 1-1/4 in. (32 mm) diam single conductor or multi conductor Type MI cable. A min 1/8 in. (3 mm) separation shall be maintained between MI cables and any other types of cable. I. Max 4/C with ground 300 kcmil (or smaller) aluminum SER cable with PVC insulation and jacket. J. Through Penetrating Product* - Any cables, Metal-Clad Cable+ or Armored Cable+ currently Classified under the Through Penetrating Products category. K. Maximum 3/C No. 8 AWG metal-clad cable. L. Maximum 5/8 diam fiber-optic cable with PVC jacket. For cable bundle penetrating the wall assembly at an angle of 45 degrees, the T, FT, FTH Ratings are 0 hr and 3/4 hr for 1 and 2 hr wall assemblies, respectively. See Through Penetrating Product (XHLY) category in the Fire Resistance Directory for names of manufacturers. 4. Fill, Void or Cavity Material*— Sealant or Putty — Fill material applied within the annulus, flush with each end of the steel sleeve or wall surface. Fill material installed symmetrically on both sides of the wall. A min 5/8 in. (16 mm) thickness of sealant is required for the 1 or 2 hr F Rating . An additional 1/2 in. (13 mm) diam bead of fill material shall be applied at the interface of sleeve with gypsum board. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — CP601S, CP606, FS-One Sealants or FS-ONE MAX Intumescent Sealantor or CP618 Putty 5. Packing Material — (Optional, Not Shown) — Mineral wool forming material may be used as a backer for the fill material (Item 4). When used, it shall be firmly packed into annular space within the sleeve as a permanent form and recessed from end of sleeve to accommodate the required thickness of fill material. * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. WL 3 0 6 5 Hilti Firestop Systems System No. W-L-3065 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. October 14, 2015 05/21/2019 05/21/2019 05/21/2019 System No. W-L-5029 SECTION A-A WL 5 0 2 9 Page: 1 of 2 A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. July 17, 2015 A 2 4 3 2 3 4 Hilti Firestop Systems 1 C CL A S S IFI E D Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US ANSI/UL1479 (ASTM E814)CAN/ULC S115 F Ratings — 1, 2 and 3 Hr (See Items 1, 3 and 4)F Ratings — 1, 2 and 3 Hr (See Items 1, 3 and 4) T Ratings — 0, 1/2, 1 and 1-1/4 Hr (See Item 3)FT Ratings — 0, 1/2, 1 and 1-1/4 Hr (See Item 3) L Rating At Ambient — 4 CFM/Sq Ft FH Ratings — 1, 2 and 3 Hr (See Items 1, 2 and 4) L Rating At 400 F — Less Than 1 CFM/Sq Ft FTH Ratings — 0, 1/2, 1 and 1-1/4 Hr (See Item 3) L Rating At Ambient — 4 CFM/Sq Ft L Rating At 400 F — Less Than 1 CFM/Sq Ft 1. Wall Assembly — The 1, 2 or 3 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide for 1 and 2 hr F and FH rating and 3-1/2 in. (89 mm) wide for 3 hr F and FH rating and spaced max 24 in. (610 mm) OC. B. Gypsum Board* — Min 5/8 in. (16 mm) thick with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max diam of opening is 18-5/8 in. (473 mm). The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrants — One metallic pipe or tubing to be installed within the firestop system. Pipe or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes or tubing may be used: A. Steel Pipe — Nom 12 in. (305 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe — Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe. C. Copper Tubing — Nom 6 in. (152 mm) diam (or smaller) Type L (or heavier) copper tubing. When the hourly F or FH Rating of the firestop system is 3 hr, the nom diam of copper tube shall not exceed 4 in. (102 mm). D. Copper Pipe — Nom 6 in. (152 mm) diam (or smaller) Regular (or heavier) copper pipe. When the hourly F or FH Rating of the firestop system is 3 hr, the nom diam of copper pipe shall not exceed 4 in. (102 mm). 05/21/2019 Page: 2 of 2 WL 5 0 2 9 Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. July 17, 2015Hilti Firestop Systems 3. Pipe Covering* — Nom 1, 1-1/2 or 2 in. (25, 38 or 51 mm) thick hollow cylindrical heavy density (min 3.5 pcf or 56 kg/m3) glass fiber units jacketed on the outside with an all service jacket. Longitudinal joints sealed with metal fasteners or factory-applied self-sealing lap tape. Transverse joints secured with metal fasteners or with butt tape supplied with the product. For 1 and 2 hr F and FH Ratings, the annular space between insulated penetrant and periphery of opening shall be min 0 in. (point contact) to max 1-7/8 in. (48 mm). For 3 hr F and FH Ratings, the annular space shall be min 0 in. (point contact) to max 1-1/4 in. (32 mm). See Pipe and Equipment Covering — Materials (BRGU) category in the Building Material Directory for the names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used. The hourly T, FT, FTH Ratings of the firestop system are 1/2 hr for 1 hr rated walls and 1 hr for 2 hr rated walls. For 3 hr rated walls, the hourly T, FT and FTH Ratings when steel and iron pipes are used are 1 hr. For 3 hr rated walls, the hourly T, FT and FTH Ratings when copper penetrants are used are 1-1/4 hr for 2 in. (51 mm) thick pipe covering and 0 hr for pipe covering thickness less than 2 in. (51 mm). 3A. Pipe Covering* — (Not Shown) — As an alternate to Item 3, max 2 in. (51 mm) thick cylindrical calcium silicate (min 14 pcf) units sized to the outside diam of the pipe or tube may be used. Pipe insulation secured with stainless steel bands or min 18 AWG stainless steel wire spaced max 12 in. (305 mm) OC. When the alternate pipe covering is used, the T and FT Rating shall be as specified in item 3 above. See Pipe and Equipment Covering — Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 or less may be used. 4. Fill, Void or Cavity Material* — Sealant — For 1 and 2 hr F and FH Rating, min 5/8 in. (16 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. For 3 hr F and FH Rating, min 1 in. (25 mm) thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point contact location between pipe covering and gypsum board, a min 1/2 in. (13 mm) diam bead of fill material shall be applied at the pipe covering/gypsum board interface on both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC — FS-One Sealant or FS-ONE MAX Intumescent Sealant * Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada), respectively. System No. W-L-5029 05/21/2019 Product Information Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide In t r o d u c t i o n Ap p l i c a t i o n s a n d P r o d u c t s Se l e c t o r G u i d e Th r o u g h - P e n e t r a t i o n Jo i n t Re f e r e n c e D a t a Flexible Firestop Sealant (CP 606) Product description ■An acrylic based firestop sealant that provides movement capability in fire rated joints and seals through-penetrations applications Product features ■Silicone free ■Halogen, asbestos and solvent free ■Paintable ■Tested up to 33% movement with 500 cycles in accordance to UL 2079 and ASTM 1966 ■Smoke and fume resistant ■Easy clean up with water ■Single component systems available ■Meets LEED™ requirements for indoor environmental quality credit 4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints and Coatings Areas of application ■Sealing construction/expansion joints ■Top-of-wall joints ■Metal pipes ■Cable bundles ■HVAC penetrations For use with ■Various base materials such as masonry, concrete, gypsum, etc. ■Wall and floor assemblies rated up to 3 hours Examples ■Where a gypsum wall assembly meets the underside of a metal or concrete deck ■Sealing expansion joints to impede the passage of fire, smoke and toxic fumes ■Sealing around HVAC penetrations through fire-rated assemblies FM $33529(' )RU3HQHWUDWLRQ)LUH6WRSV &RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH R FILL, VOID OR CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. FOR USE IN TROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 Notice • Before handling, read Material Safety Data Sheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information • The use of backing material is recommended to control the sealant depth and help ensure assembly seal is complete Opening 1. Clean the opening. Surfaces to which CP 606 will be applied should be cleaned of loose debris, dirt, oil, wax and grease. The surface should be moisture and frost free. Application of firestop 2. Insert fill of mineral wool or backer (as required). 3. Apply firestop over backer. 4. Smooth firestop sealant with a trowel before the skin forms. Once cured, CP 606 can only be removed mechanically. 5. For maintenance reasons, a penetration seal can be permanently marked with an identification plate and fastened in a visible position next to the seal. Not for use • On areas immersed in water Storage • Store only in the original packaging in a location protected from moisture at a temperature of 40°F to 77°F (5°C to 25°C) • Observe expiration date on package Installation instructions for CP 606 1. Clean opening 2. Insert backing material compressed per UL System 3. Apply CP 606 4. Smooth CP 606 5. Fasten identification plate (if required) 1. Clean opening 2. Insert backing material 3. Apply CP 606 4. Smooth CP 606 5. Fasten identification plate (if required) FirestopSystem FirestopSystemFirestopSystem JO I N T DU C T FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS AND JOINT SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 Technical Data* CP 606 Chemical basis Acrylic based firestop sealant Color Available in red, white and gray Application temperature 40°F to 104°F (5°C to 40°C) Skin-forming time Approx. 15 min Curing time Approx. 3 mm / 3 days Average volume shrinkage (ASTM C1241) 22.2% Movement capability Approx. 10% Temperature resistance –22°F to 176°F (–30°C to 80°C) Surface burning characteristics (ASTM E 84-96) Flame Spread: 10 Smoke Development: 0 Sound transmission classification (ASTM E 90-99) 56 (Relates to specific construction) Tested in accordance with • UL 2079 • ASTM E 814 • ASTM E 1966 • ASTM E 84 • UL 1479 • ASTM G21 *At 73°F (23°C) and 50% relative humidity 05/21/2019 CERTIFICATE OF COMPLIANCE Certificate Number 20160930-R13240 Report Reference R13240 Issue Date 2016-September-30 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 1 of 1 Issued to: Hilti Construction Chemicals, Div of Hilti Inc. 5400 S 122nd East Ave Tulsa, OK 74146 This is to certify that representative samples of Fill, Void or Cavity Materials Fill, Void or Cavity Materials Certified for Canada CP 606 Sealant for use in Through-Penetration Firestop, Joint in wall and partition Systems as currently decribed in the UL Fire Resistance Directory and in the Products Certified for Canada Directory. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Through-Penetration Firestops," ANSI/UL 2079, "Tests for Fire Resistance of Building Joint Systems," CAN/ULC-S115, "Standard Method of Fire Tests of Firestop Systems." Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. 05/21/2019 Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations Date of issue: 01/07/2016 Revision date: 01/07/2016 Supersedes: 01/07/2016 Version: 4.2 07/01/2016 EN (English) 1/7 SECTION 1: Identification 1.1. Identification Product form Mixture Name Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606 Product code BU Chemicals Chemical structure 1.2. Relevant identified uses of the substance or mixture and uses advised against No additional information available 1.3. Details of the supplier of the safety data sheet Hilti, Inc. Legacy Tower, Suite 1000 75024 Plano - USA T +1 9724035800 1-800-879-8000 toll free - F +1 918 254 0522 Supplier Hilti, Inc. Legacy Tower, Suite 1000 75024 Plano - USA T +1 9724035800 1-800-879-8000 toll free - F +1 918 254 0522 Department issuing data specification sheet Hilti AG Feldkircherstraße 100 9494 Schaan - Liechtenstein T +423 234 2111 chemicals.hse@hilti.com 1.4. Emergency telephone number Emergency number Chem-Trec Tel.: 1 800 424 9300 (USA, PR, Virgin Islands, Canada) Tel.: 703 527 3887 (Other countries) +1 918 8723000 1-800-879-8000 toll free SECTION 2: Hazards identification 2.1. Classification of the substance or mixture GHS-US classification Not classified 2.2. Label elements GHS-US labelling No labelling applicable 2.3. Other hazards No additional information available 2.4. Unknown acute toxicity (GHS US) Not applicable 05/21/2019 Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 07/01/2016 EN (English) 2/7 SECTION 3: Composition/information on ingredients 3.1. Substance Not applicable 3.2. Mixture Full text of H-statements: see section 16 SECTION 4: First aid measures 4.1. Description of first aid measures First-aid measures after inhalation Get medical advice/attention if you feel unwell. First-aid measures after skin contact Wash skin with plenty of water. If skin irritation occurs: Get medical advice/attention. First-aid measures after eye contact Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention. First-aid measures after ingestion Get medical advice/attention if you feel unwell. 4.2. Most important symptoms and effects, both acute and delayed No additional information available 4.3. Indication of any immediate medical attention and special treatment needed No additional information available SECTION 5: Firefighting measures 5.1. Extinguishing media Suitable extinguishing media Water spray. Dry powder. Foam. Carbon dioxide. 5.2. Special hazards arising from the substance or mixture Reactivity The product is non-reactive under normal conditions of use, storage and transport. 5.3. Advice for firefighters Protection during firefighting Self-contained breathing apparatus. Complete protective clothing. SECTION 6: Accidental release measures 6.1. Personal precautions, protective equipment and emergency procedures 6.1.1. For non-emergency personnel No additional information available 6.1.2. For emergency responders Protective equipment For further information refer to section 8: "Exposure controls/personal protection". 6.2. Environmental precautions No additional information available 6.3. Methods and material for containment and cleaning up Methods for cleaning up Recover mechanically the product. 6.4. Reference to other sections For further information refer to section 13. 05/21/2019 Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 07/01/2016 EN (English) 3/7 SECTION 7: Handling and storage 7.1. Precautions for safe handling Precautions for safe handl ing Wear personal protective equipment. Hygiene measures Wash contaminated clothing before reuse. Do not eat, drink or smoke when using this product. Always wash hands after handling the product. 7.2. Conditions for safe storage, including any incompatibilities Storage conditions Keep cool. Store in a dry place. Storage temperature 41 - 77 °F SECTION 8: Exposure controls/personal protection 8.1. Control parameters No additional information available 8.2. Exposure controls Personal protective equipment Protective clothing. Safety glasses. Gloves. Hand protection Protective gloves. EN 374. Eye protection Safety glasses. EN 166. EN 170. Skin and body protection Wear suitable protective clothing. SECTION 9: Physical and chemical properties 9.1. Information on basic physical and chemical properties Physical state Liquid Appearance Pasty. Colour red white Grey Odour characteristic Odour threshold Not determined pH ≈ 9 Not applicable Melting point Not applicable Freezing point No data available Boiling point No data available Flash point Not applicable Relative evaporation rate (butylacetate=1) No data available Flammability (solid, gas) No data available Explosive limits No data available Explosive properties No data available Oxidising properties No data available Vapour pressure No data available Relative density No data available Relative vapour density at 20 °C No data available Density 1.6 g/cm³ Molecular mass Not determined Solubility No data available 05/21/2019 Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 07/01/2016 EN (English) 4/7 Log Pow No data available Auto-ignition temperature No data available Decomposition temperature No data available Viscosity No data available Viscosity, kinematic No data available Viscosity, dynamic No data available 9.2. Other information No additional information available SECTION 10: Stability and reactivity 10.1. Reactivity The product is non-reactive under normal conditions of use, storage and transport. 10.2. Chemical stability Stable under normal conditions. 10.3. Possibility of hazardous reactions No dangerous reactions known under normal conditions of use. 10.4. Conditions to avoid None under recommended storage and handling conditions (see section 7). 10.5. Incompatible materials No additional information available 10.6. Hazardous decomposition products Under normal conditions of storage and use, hazardous decomposition products should not be produced. SECTION 11: Toxicological information 11.1. Information on toxicological effects Acute toxicity Not classified Skin corrosion/irritation Not classified pH: ≈ 9 Not applicable Serious eye damage/irritation Not classified pH: ≈ 9 Not applicable Respiratory or skin sensitisation Not classified Germ cell mutagenicity Not classified Carcinogenicity Not classified Reproductive toxicity Not classified Specific target organ toxicity (single exposure) Not classified Specific target organ toxicity (repeated exposure) Not classified Aspiration hazard Not classified 05/21/2019 Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 07/01/2016 EN (English) 5/7 SECTION 12: Ecological information 12.1. Toxicity Ecology - general The product is not considered harmful to aquatic organisms or to cause long-term adverse effects in the environment. 12.2. Persistence and degradability No additional information available 12.3. Bioaccumulative potential No additional information available 12.4. Mobility in soil No additional information available 12.5. Other adverse effects Effect on the global warming No known ecological damage caused by this product. SECTION 13: Disposal considerations 13.1. Waste treatment methods Waste treatment methods Dispose of contents/container in accordance with licensed collector’s sorting instructions. Waste disposal recommendations Dispose in a safe manner in accordance with local/national regulations. SECTION 14: Transport information In accordance with ADR / RID / IMDG / IATA / ADN 14.1. UN number Not regulated for transport 14.2. UN proper shipping name Proper Shipping Name (ADR) Not applicable Proper Shipping Name (IMDG) Not applicable Proper Shipping Name (IATA) Not applicable Proper Shipping Name (ADN) Not applicable Proper Shipping Name (RID) Not applicable 14.3. Transport hazard class(es) ADR Transport hazard class(es) (ADR) Not applicable IMDG Transport hazard class(es) (IMDG) Not applicable IATA Transport hazard class(es) (IATA) Not applicable ADN Transport hazard class(es) (ADN) Not applicable RID 05/21/2019 Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 07/01/2016 EN (English) 6/7 Transport hazard class(es) (RID) Not applicable 14.4. Packing group Packing group (ADR) Not applicable Packing group (IMDG) Not applicable Packing group (IATA) Not applicable Packing group (ADN) Not applicable Packing group (RID) Not applicable 14.5. Environmental hazards Dangerous for the environment No Marine pollutant No Other information No supplementary information available 14.6. Special precautions for user - Overland transport - Transport by sea No data available - Air transport No data available - Inland waterway transport Carriage prohibited (ADN) No Not subject to ADN No - Rail transport Carriage prohibited (RID) No 14.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code SECTION 15: Regulatory information 15.1. US Federal regulations This product or mixture does not contain a toxic chemical or chemicals in excess of the applicable de minimis concentration as specified in 40 CFR §372.38(a) subject to the reporting requirements of section 313 of Title III of the Superfund Am endments and Reauthorization Act of 1986 and 40 CFR Part 372. 15.2. International regulations CANADA Hilti Firestop Acrylic Sealant CFS-S ACR; CP 606 WHMIS Classification Uncontrolled product according to WHMIS classification criteria EU-Regulations No additional information available Classification according to Regulation (EC) No. 1272/2008 [CLP] Not classified National regulations No additional information available 05/21/2019 Hilti Firestop Acrylic Sealant CFS -S ACR; CP 606 Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 07/01/2016 EN (English) 7/7 15.3. US State regulations California Proposition 65 - This product does not contain any substances known to the state of California to cause cancer, developmental and/or reproductive harm SECTION 16: Other information Revision date 01/07/2016 HMIS III Rating Health 0 Minimal Hazard - No significant risk to health Flammability 0 Minimal Hazard - Materials that will not burn Physical 0 Minimal Hazard - Materials that are normally stable, even under fire conditions, and will NOT react with water, polymerize, decompose, condense, or self -react. Non-Explosives. Personal Protection B B - Safety glasses, Gloves SDS_US_Hilti This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product 05/21/2019 Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com February 26, 2010 To Whom It May Concern: Re: Hilti CP 606 Flexible Firestop – LEEDs Info. The Hilti CP 606 Flexible Firestop Sealant is manufactured in Germany. The CP 606 pail is made of polyethylene and can be completely recycled. There is no post- consumer or post-industrial content in CP 606 and it cannot be recycled. The CP 606 does not contain any Rapidly Renewable Materials. The VOC content for CP 606 is 71.0 grams/liter. CP 606 is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Safety/Environmental Manager Hilti Inc. 918 872 3704 jerry.metcalf@hilti.com Rev. Date: 2/26/10 05/21/2019 Hilti Firestop Saving lives through innovation and education Product Information Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide In t r o d u c t i o n Ap p l i c a t i o n s a n d P r o d u c t s Se l e c t o r G u i d e Th r o u g h - P e n e t r a t i o n Jo i n t Re f e r e n c e D a t a Firestop Collar (CP 643N) Product description ■A ready-to-use firestop collar, made of a galvanized steel housing and intumescent inserts for firestopping combustible pipes Product features ■Ready-to-use collar ■No construction required ■Fast installation time ■Adjustable mounting tabs ■Low profile for tight installations Areas of application ■Firestopping combustible pipes up to 6" diameter in penetrations through fire walls and floors ■Suitable for the following pipe materials: ■ PVC, CPVC, ABS, PVDF, PP and FRPP For use with ■Concrete, masonry, wood floor and gypsum wall assemblies ■Wall and floor assemblies rated up to 4 hours Types of installation ■Wall: two collars, one on each side ■Floor: one collar on underside (bottom) Example ■Waste water pipes ■Fresh water pipes Installation instructions for CP 643N VRGIPHYL - G M I L Z K U L X K 1|R:( ==DZ| S  L  H ‰ XX ] H LNLUGZLOR L  M W I  | [   Y E Y E Y K LUHLY X‰RHR R &3%UD Q G V F K X W ] P D Q V F K  Notice • Before handling, read Material Safety Data Sheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Opening 1. Clean the plastic pipes. Expansion of the intumescent material during a fire acts to close the plastic pipe. Very dirty pipes (ie: with remains of mortar) may lead to a delay in this closing action. Soiled plastic pipes should, therefore, be cleaned in the area where the CP 643N Firestop Collar is to be installed. Application of firestop system 2. Seal the opening if required. Gaps may be closed with FS-ONE. The approved methods vary and are given in the specific UL system. 3. Close the CP 643N Firestop Collar. Place the CP 643N Firestop Collar around the plastic pipe and lock the closure by applying firm pressure until it latches. 4. Attach fastening hooks. The fastening hooks can be attached to various points on the metal hous ing. This allows the fastening points to be made to suit the space available in each case. The hooks must be positioned as symmetrically as possible. The required number of fastening hooks is indicated on the packaging. 5. Fastening the CP 643N Firestop Collar. Only when fastened properly can CP 643N offer protection against fire. a. Mark the fastening points. b. Drill holes with a Hilti rotary hammer drill (i.e. TE 4-A18) or, depending on base material, fasten using Hilti powder-actuated tool. c. To secure the CP 643N Firestop Collar, use Hilti anchors/fasteners. d. For maintenance reasons, a penetration can be permanently marked with an identification plate and fastened in a visible position next to the seal. Not for use • With metal pipes • In highly corrosive surroundings • With unapproved anchors/fasteners Storage • Store only in the original packaging in a location protected from moisture 1. Clean plastic pipe.2. Close remaining gap to provide smoke and gas resistant seal. 3. Close collar.4. Attach fastening hooks.5. Fasten collar and identification plate (if required). )LUHVWRS6\VWHP FM $33529(' )RU3HQHWUDWLRQ)LUH6WRSV &RQVXOWWKH)DFWRU\0XWXDO5HVHDUFK&RUSRUDWLRQ$SSURYDO*XLGH R FILL, VOID OR CAVITY MATERIALS CLASSIFIED BY UNDERWRITERS LABORATORIES, INC. FOR USE IN TROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 FIRESTOP DEVICE FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 5N76 Technical Data CP 643N Pipe outside Description dia (in.) Collar Collar No. of outside Height hooks and dia. (in.) (in.) fasteners CP 643-50/1.5"N 1.4–2.0 2.8 0.9 2 CP 643-63/2"N 2.0–2.5 3.4 1.3 2 CP 643-90/3"N 2.6–3.6 4.9 1.7 3 CP 643-110/4"N 3.6–4.5 6.0 1.9 3 CP 643-160/6"N 6.6 9.8 1.9 4 Temperature resistance -40°F to 140°F (–40°C to 60°C) Intumescent activation Approx. 392°F (200°C) Expansion ratio (unrestricted)Up to 1:10 Tested in accordance with • UL 1479 • ASTM E 814 • ASTM G21 Visit fbcsystemcompatible.com. FBC™ is a trademark of the Lubrizol Corporation. 05/21/2019 CERTIFICATE OF COMPLIANCE Certificate Number 20160125-R15431 Report Reference R15431-19980323 Issue Date 2016-JANUARY-25 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 1 of 1 Issued to: HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC 5400 S 122ND EAST AVE TULSA OK 74146 This is to certify that representative samples of FIRESTOP DEVICES Firestop devices designated CP 643 50/1.5” N, CP 643 63/2” N, CP 643 75/2.5” N, CP 643 90/3” N, CP 643 110/4” N, CP 643 125/5” N, CP 643 160/6” N, CP 644 200/8” and CP 644 250/10” for use in specific through-penetration firestop systems. The various suffixes for the designations of the firestop devices indicates the nominal outside diameter of the pipe (mm/in.) on which the device is intended to be installed. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 1479 STANDARD FOR FIRE TESTS OF PENETRATION FIRESTOPS. CAN/ULC S115 STANDARD METHOD OF FIRE TESTS OF FIRESTOP SYSTEMS Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. 05/21/2019 Page 1/5 Safety Data Sheet acc. to ISO 11014 Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3 40.2.7 * 1 Identification · Product identifier · Trade name: Hilti Firestop Collar CFS-C Hilti Firestop Collar Plus CFS-C P Hilti Firestop Bandage CFS-B Hilti Firestop Wrap Strip Endless CFS-W EL Hilti Firestop Wrap Strip Single CFS-W SG Hilti Firestop Collar Endless CFS-C EL Hilti Firestop Back Pan Strip CFS-BPS CP 643 CP 644 CP 646 CP 648 · Relevant identified uses of the substance or mixture and uses advised against No further relevant information available. · Application of the substance / the mixture Construction chemicals · Details of the supplier of the safety data sheet · Manufacturer/Supplier: Hilti, Inc. 5400 South 122nd East Ave. US-Tulsa, OK 74146 Phone: (800) 879-8000 Fax: (800) 879-7000 Español: (800) 879-5000 · Information department: see section 16 chemicals.hse@hilti.com · Emergency telephone number: Tox Info Suisse - 24 h Service Tel.: 0041 / 44 251 51 51 (international) . Chem-Trec Tel.: 1 800 424 9300 2 Hazard(s) identification · Classification of the substance or mixture The product is not classified according to the Globally Harmonized System (GHS). · Classification according to Directive 67/548/EEC or Directive 1999/45/EC not applicable · Information concerning particular hazards for human and environment: The product does not have to be labelled due to the calculation procedure of the "General Classification guideline for preparations of the EU" in the latest valid version. · Classification system: The classification was made according to the latest editions of the EU-lists, and expanded upon from company and literature data. · Label elements · GHS label elements Void · Hazard pictograms Void · Signal word Void · Hazard statements Void · Other hazards · Results of PBT and vPvB assessment · PBT:Not applicable. · vPvB:Not applicable. * 3 Composition/information on ingredients · Chemical characterization: Mixtures · Description:Polymer-bonded intumescent material (in the metal or plastic housing) · Dangerous components:Void 4 First-aid measures · Description of first aid measures · General information No special measures required. · After inhalation Not applicable · After skin contact Not applicable · After eye contact Not applicable · After swallowing Not applicable · Information for doctor · Most important symptoms and effects, both acute and delayed No further relevant information available. · Indication of any immediate medical attention and special treatment needed No further relevant information available. US (Contd. on page 2) 05/21/2019 Page 2/5 Safety Data Sheet acc. to ISO 11014 Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3 (Contd. of page 1) 40.2.7 5 Fire-fighting measures · Extinguishing media · Suitable extinguishing agents CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam. · Special hazards arising from the substance or mixture No further relevant information available. · Advice for firefighters · Protective equipment:No special measures required. 6 Accidental release measures · Personal precautions, protective equipment and emergency procedures Not required. · Environmental precautions:No special measures required. · Methods and material for containment and cleaning up:Pick up mechanically. · Reference to other sections See Section 8 for information on personal protection equipment. See Section 13 for disposal information. 7 Handling and storage · Handling · Precautions for safe handling No special measures required. · Information about protection against explosions and fires:No special measures required. · Conditions for safe storage, including any incompatibilities · Storage · Requirements to be met by storerooms and receptacles:No special requirements. · Information about storage in one common storage facility:Not required. · Further information about storage conditions:None. · Storage class 13 · Specific end use(s)No further relevant information available. 8 Exposure controls/personal protection · Control parameters · Components with limit values that require monitoring at the workplace: The product does not contain any relevant quantities of materials with critical values that have to be monitored at the workplace. · Additional information:The lists that were valid during the creation were used as basis. · Exposure controls · Personal protective equipment · Breathing equipment:Not required. · Protection of hands: Protective gloves. To avoid skin problems reduce the wearing of gloves to the required minimum. · Material of gloves The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. · Penetration time of glove material Not required. · Body protection: Protective work clothing. 9 Physical and chemical properties · Information on basic physical and chemical properties · General Information · Appearance: Form:Solid. Color:Various colors · Odor:Odorless · pH-value:Not determined. · Change in condition Melting point/Melting range:Not determined. (Contd. on page 3) US 05/21/2019 Page 3/5 Safety Data Sheet acc. to ISO 11014 Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3 (Contd. of page 2) 40.2.7 Boiling point/Boiling range:undetermined · Flash point:Not applicable · Flammability (solid, gaseous)Product is not flammable. · Ignition temperature: Decomposition temperature:Not determined. · Danger of explosion:Product does not present an explosion hazard. · Vapor pressure:Not applicable. · Density at 20 °C (68 °F):1.3-1.4 g/cm³ (10.849-11.68 lbs/gal) · Evaporation rate Not applicable. · Solubility in / Miscibility with Water:Insoluble · Partition coefficient (n-octanol/water):Not determined. · Viscosity: dynamic:Not applicable. kinematic:Not applicable. · Solvent content: Solids content:100 % · Other information CP 643, CP 644 - VOC Content: 7.6 g/l (EPA Method 24) CP 648, CFS-BPS - VOC Content: 3.1 g/l (EPA Method 24) 10Stability and reactivity · Reactivity · Chemical stability · Thermal decomposition / conditions to be avoided:No decomposition if used according to specifications. · Possibility of hazardous reactions No dangerous reactions known · Conditions to avoid No further relevant information available. · Incompatible materials:No further relevant information available. · Hazardous decomposition products:No dangerous decomposition products known 11Toxicological information · Information on toxicological effects · Acute toxicity: · Primary irritant effect: · on the skin:No irritant effect. · on the eye:No irritating effect. · Sensitization:No sensitizing effects known. · Additional toxicological information: When used and handled according to specifications, the product does not have any harmful effects according to our experience and the information provided to us. · IARC (International Agency for Research on Cancer) None of the ingredients is listed. · NTP (National Toxicology Program) None of the ingredients is listed · OSHA-Ca (Occupational Safety & Health Administration) None of the ingredients is listed. 12Ecological information · Toxicity · Aquatic toxicity:No further relevant information available. · Persistence and degradability No further relevant information available. · Behavior in environmental systems: · Bioaccumulative potential No further relevant information available. · Mobility in soil No further relevant information available. · Ecotoxical effects:Not determined · Results of PBT and vPvB assessment · PBT:Not applicable. · vPvB:Not applicable. · Other adverse effects No further relevant information available. US (Contd. on page 4) 05/21/2019 Page 4/5 Safety Data Sheet acc. to ISO 11014 Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3 (Contd. of page 3) 40.2.7 13Disposal considerations · Waste treatment methods · Recommendation Smaller quantities can be disposed of with household waste. · European waste catalogue: 17 02 03 plastic 17 04 05 iron and steel · Uncleaned packagings: · Recommendation: Disposal must be made according to official regulations. Dispose of packaging according to regulations on the disposal of packagings. Empty packs: May be disposed via the local Green Dot collecting system or EAK waste material code 150102 (plastic packaging materials) 14Transport information · UN-Number · DOT, ADR, ADN, IMDG, IATA Void · UN proper shipping name · DOT, ADR, ADN, IMDG, IATA Void · Transport hazard class(es) · DOT, ADR, ADN, IMDG, IATA · Class Void · Packing group · DOT, ADR, IMDG, IATA Void · Environmental hazards: · Marine pollutant:No · Special precautions for user Not applicable · Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code Not applicable. · Transport/Additional information:Not dangerous according to the above specifications. · UN "Model Regulation":- 15Regulatory information · Safety, health and environmental regulations/legislation specific for the substance or mixture · Sara · Section 355 (Extremely hazardous substances): None of the ingredients is listed. · Section 313 (Specific toxic chemical listings): None of the ingredients are listed. · TSCA (Toxic Substances Control Act): All ingredients are listed. · Proposition 65: · Chemicals known to cause cancer: None of the ingredients are listed. · Cancerogenity categories · EPA (Environmental Protection Agency) None of the ingredients is listed. · TLV (Threshold Limit Value established by ACGIH) None of the ingredients is listed. · MAK (German Maximum Workplace Concentration) None of the ingredients is listed. · NIOSH-Ca (National Institute for Occupational Safety and Health) None of the ingredients is listed. · Chemical safety assessment:not required. 16Other information This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship. · Department issuing SDS: Hilti Corporation Business Unit Chemicals Quality/Safety/Environment (Contd. on page 5) US 05/21/2019 Page 5/5 Safety Data Sheet acc. to ISO 11014 Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3 (Contd. of page 4) 40.2.7 FL-9494 Schaan / Liechtenstein chemicals.hse@hilti.com Tel.: +423 234 3004 FAX.: +423 234 3462 · Date of preparation / last revision 05/18/2015 / 2 · Abbreviations and acronyms: ADR: Accord européen sur le transport des marchandises dangereuses par Route (European Agreement concerning the International Carriage of Dangerous Goods by Road) IMDG: International Maritime Code for Dangerous Goods DOT: US Department of Transportation IATA: International Air Transport Association ACGIH: American Conference of Governmental Industrial Hygienists EINECS: European Inventory of Existing Commercial Chemical Substances ELINCS: European List of Notified Chemical Substances CAS: Chemical Abstracts Service (division of the American Chemical Society) · * Data compared to the previous version altered. US 05/21/2019 Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1 -800-879-8000 www.hilti.com August 26, 2015 To Whom It May Concern: Re: CP 643N/644 Firestop Collars – LEED Information Item Numbers: 304325 304326 304328 304329 304331 304341 304344 The Hilti CP 643N/644 Firestop Collars are manufactured in Germany. The Hilti CP 643N/644 Firestop Collars have a VOC content of 7.6 grams/liter. The amount of post-consumer or post-industrial content in CP 643N/644 Firestop Collars is not known. The metal portions of the collars are recyclable. The CP 643N/644 Firestop Collars do not contain any Rapidly Renewable Materials. The CP 643N/644 Firestop Collars are not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Sr. Manager, Safety/Environmental Hilti Inc. (918) 872 3704 jerry.metcalf@hilti.com Rev. Date: 8/14/15 The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America requirements, as those requirements differ. The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced non-catalog Hilti products may have differing manufacturing plant locations. Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates. 05/21/2019 Hilti Firestop Saving lives through innovation and education Product Information Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide Firestop Collar (CP 644) Product description ■A ready-to-use firestop collar, made of galvanized steel housing and intumescent inserts for firestopping large combustible pipes Product features ■Ready-to-use collar ■No construction required ■Fast installation time ■Adjustable/moveable fastening tabs Areas of application ■Sealing of penetrations for combustible pipes from 8" to 10" in diameter ■Vented or closed pipe ■PVC or CPVC pipe For use with ■Concrete, masonry, and gypsum walls ■Wall and floor assemblies rated up to 2 hours Types of installation ■Wall: two collars, one on each side ■Floor: one collar on underside (bottom) Examples ■Waste water pipes ■Fresh water pipes Installation instructions for CP 644 VRGIPHY L - G M I L Z K U L XK1|R: ( ==DZ| S  LH‰ X   X ] H LNLUGZLOR L  M W I  | [YEYEYK  L U H L Y X‰RH R R &3%UD Q G V F KXW]PDQVF K  Notice • Before handling, read Material Safety Data Sheet and product label for safe usage and health information. • Instructions below are general guidelines — always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Opening 1. Clean the plastic pipes. Expansion of the intumescent material during a fire acts to close the plastic pipe. Very dirty pipes, (ie: with remains of mortar) may lead to a delay in this closing action. Soiled plastic pipes should, therefore, be cleaned in the area where the CP 644 Firestop Collar is to be installed. Application of firestop system 2. Seal the opening. Gaps must be closed with FS- ONE. The approved methods vary and are given in the specific UL system. 3. Close the CP 644 Firestop Collar. Place the CP 644 Firestop Collar around the plastic pipe and lock the closure by applying firm pressure until it latches. 4. Attach fastening hooks. The fastening hooks can be attached to various points on the metal hous ing. This allows the fastening points to be made to suit the space available in each case. The hooks must be positioned as symmetrically as possible. The required number of fastening hooks is indicated on the packaging. 5. Fastening the CP 644 Firestop Collar. Only when fastened properly can CP 644 offer protection against fire passing through. a. Mark the fastening points. b. Drill holes with a Hilti rotary hammer drill (i.e. TE 4-A18) or, depending on base material, fasten using Hilti powder-actuated tool. c. To secure the CP 644 Firestop Collar, use Hilti anchors/fasteners. d. For maintenance reasons, a penetration can be permanently marked with an identification plate and fastened in a visible position next to the seal. Not for use • With metal pipes • In highly corrosive surroundings • With unapproved anchors/fasteners Storage • Store only in the original packaging in a location protected from moisture FIRESTOP DEVICE FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 5N76 )LUHVWRS6\VWHP Technical Data CP 644 Pipe outside Description dia (in.) Collar Collar No. of outside Height hooks and dia. (in.) (in.) fasteners CP 644-200/8" 8.8 10.0 6.9 10 CP 644-250/10" 10.8 12.4 9.1 12 Temperature resistance -40°F to 140°F (–40°C to 60°C) Intumescent Activation Approx. 392°F (200°C) Expansion ratio (unrestricted)Up to 1:10 Tested in accordance with • UL 1479 • ASTM E 814 • ASTM G21 1. Clean plastic pipe 2. Close remaining gap to provide smoke and gas resistant seal 3. Close collar 4. Attach fastening hooks 5. Fasten collar and identification plate. (If required) 05/21/2019 CERTIFICATE OF COMPLIANCE Certificate Number 20160125-R15431 Report Reference R15431-19980323 Issue Date 2016-JANUARY-25 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 1 of 1 Issued to: HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC 5400 S 122ND EAST AVE TULSA OK 74146 This is to certify that representative samples of FIRESTOP DEVICES Firestop devices designated CP 643 50/1.5” N, CP 643 63/2” N, CP 643 75/2.5” N, CP 643 90/3” N, CP 643 110/4” N, CP 643 125/5” N, CP 643 160/6” N, CP 644 200/8” and CP 644 250/10” for use in specific through-penetration firestop systems. The various suffixes for the designations of the firestop devices indicates the nominal outside diameter of the pipe (mm/in.) on which the device is intended to be installed. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: UL 1479 STANDARD FOR FIRE TESTS OF PENETRATION FIRESTOPS. CAN/ULC S115 STANDARD METHOD OF FIRE TESTS OF FIRESTOP SYSTEMS Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. 05/21/2019 Page 1/5 Safety Data Sheet acc. to ISO 11014 Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3 40.2.7 * 1 Identification · Product identifier · Trade name: Hilti Firestop Collar CFS-C Hilti Firestop Collar Plus CFS-C P Hilti Firestop Bandage CFS-B Hilti Firestop Wrap Strip Endless CFS-W EL Hilti Firestop Wrap Strip Single CFS-W SG Hilti Firestop Collar Endless CFS-C EL Hilti Firestop Back Pan Strip CFS-BPS CP 643 CP 644 CP 646 CP 648 · Relevant identified uses of the substance or mixture and uses advised against No further relevant information available. · Application of the substance / the mixture Construction chemicals · Details of the supplier of the safety data sheet · Manufacturer/Supplier: Hilti, Inc. 5400 South 122nd East Ave. US-Tulsa, OK 74146 Phone: (800) 879-8000 Fax: (800) 879-7000 Español: (800) 879-5000 · Information department: see section 16 chemicals.hse@hilti.com · Emergency telephone number: Tox Info Suisse - 24 h Service Tel.: 0041 / 44 251 51 51 (international) . Chem-Trec Tel.: 1 800 424 9300 2 Hazard(s) identification · Classification of the substance or mixture The product is not classified according to the Globally Harmonized System (GHS). · Classification according to Directive 67/548/EEC or Directive 1999/45/EC not applicable · Information concerning particular hazards for human and environment: The product does not have to be labelled due to the calculation procedure of the "General Classification guideline for preparations of the EU" in the latest valid version. · Classification system: The classification was made according to the latest editions of the EU-lists, and expanded upon from company and literature data. · Label elements · GHS label elements Void · Hazard pictograms Void · Signal word Void · Hazard statements Void · Other hazards · Results of PBT and vPvB assessment · PBT:Not applicable. · vPvB:Not applicable. * 3 Composition/information on ingredients · Chemical characterization: Mixtures · Description:Polymer-bonded intumescent material (in the metal or plastic housing) · Dangerous components:Void 4 First-aid measures · Description of first aid measures · General information No special measures required. · After inhalation Not applicable · After skin contact Not applicable · After eye contact Not applicable · After swallowing Not applicable · Information for doctor · Most important symptoms and effects, both acute and delayed No further relevant information available. · Indication of any immediate medical attention and special treatment needed No further relevant information available. US (Contd. on page 2) 05/21/2019 Page 2/5 Safety Data Sheet acc. to ISO 11014 Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3 (Contd. of page 1) 40.2.7 5 Fire-fighting measures · Extinguishing media · Suitable extinguishing agents CO2, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam. · Special hazards arising from the substance or mixture No further relevant information available. · Advice for firefighters · Protective equipment:No special measures required. 6 Accidental release measures · Personal precautions, protective equipment and emergency procedures Not required. · Environmental precautions:No special measures required. · Methods and material for containment and cleaning up:Pick up mechanically. · Reference to other sections See Section 8 for information on personal protection equipment. See Section 13 for disposal information. 7 Handling and storage · Handling · Precautions for safe handling No special measures required. · Information about protection against explosions and fires:No special measures required. · Conditions for safe storage, including any incompatibilities · Storage · Requirements to be met by storerooms and receptacles:No special requirements. · Information about storage in one common storage facility:Not required. · Further information about storage conditions:None. · Storage class 13 · Specific end use(s)No further relevant information available. 8 Exposure controls/personal protection · Control parameters · Components with limit values that require monitoring at the workplace: The product does not contain any relevant quantities of materials with critical values that have to be monitored at the workplace. · Additional information:The lists that were valid during the creation were used as basis. · Exposure controls · Personal protective equipment · Breathing equipment:Not required. · Protection of hands: Protective gloves. To avoid skin problems reduce the wearing of gloves to the required minimum. · Material of gloves The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. · Penetration time of glove material Not required. · Body protection: Protective work clothing. 9 Physical and chemical properties · Information on basic physical and chemical properties · General Information · Appearance: Form:Solid. Color:Various colors · Odor:Odorless · pH-value:Not determined. · Change in condition Melting point/Melting range:Not determined. (Contd. on page 3) US 05/21/2019 Page 3/5 Safety Data Sheet acc. to ISO 11014 Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3 (Contd. of page 2) 40.2.7 Boiling point/Boiling range:undetermined · Flash point:Not applicable · Flammability (solid, gaseous)Product is not flammable. · Ignition temperature: Decomposition temperature:Not determined. · Danger of explosion:Product does not present an explosion hazard. · Vapor pressure:Not applicable. · Density at 20 °C (68 °F):1.3-1.4 g/cm³ (10.849-11.68 lbs/gal) · Evaporation rate Not applicable. · Solubility in / Miscibility with Water:Insoluble · Partition coefficient (n-octanol/water):Not determined. · Viscosity: dynamic:Not applicable. kinematic:Not applicable. · Solvent content: Solids content:100 % · Other information CP 643, CP 644 - VOC Content: 7.6 g/l (EPA Method 24) CP 648, CFS-BPS - VOC Content: 3.1 g/l (EPA Method 24) 10Stability and reactivity · Reactivity · Chemical stability · Thermal decomposition / conditions to be avoided:No decomposition if used according to specifications. · Possibility of hazardous reactions No dangerous reactions known · Conditions to avoid No further relevant information available. · Incompatible materials:No further relevant information available. · Hazardous decomposition products:No dangerous decomposition products known 11Toxicological information · Information on toxicological effects · Acute toxicity: · Primary irritant effect: · on the skin:No irritant effect. · on the eye:No irritating effect. · Sensitization:No sensitizing effects known. · Additional toxicological information: When used and handled according to specifications, the product does not have any harmful effects according to our experience and the information provided to us. · IARC (International Agency for Research on Cancer) None of the ingredients is listed. · NTP (National Toxicology Program) None of the ingredients is listed · OSHA-Ca (Occupational Safety & Health Administration) None of the ingredients is listed. 12Ecological information · Toxicity · Aquatic toxicity:No further relevant information available. · Persistence and degradability No further relevant information available. · Behavior in environmental systems: · Bioaccumulative potential No further relevant information available. · Mobility in soil No further relevant information available. · Ecotoxical effects:Not determined · Results of PBT and vPvB assessment · PBT:Not applicable. · vPvB:Not applicable. · Other adverse effects No further relevant information available. US (Contd. on page 4) 05/21/2019 Page 4/5 Safety Data Sheet acc. to ISO 11014 Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3 (Contd. of page 3) 40.2.7 13Disposal considerations · Waste treatment methods · Recommendation Smaller quantities can be disposed of with household waste. · European waste catalogue: 17 02 03 plastic 17 04 05 iron and steel · Uncleaned packagings: · Recommendation: Disposal must be made according to official regulations. Dispose of packaging according to regulations on the disposal of packagings. Empty packs: May be disposed via the local Green Dot collecting system or EAK waste material code 150102 (plastic packaging materials) 14Transport information · UN-Number · DOT, ADR, ADN, IMDG, IATA Void · UN proper shipping name · DOT, ADR, ADN, IMDG, IATA Void · Transport hazard class(es) · DOT, ADR, ADN, IMDG, IATA · Class Void · Packing group · DOT, ADR, IMDG, IATA Void · Environmental hazards: · Marine pollutant:No · Special precautions for user Not applicable · Transport in bulk according to Annex II of MARPOL73/78 and the IBC Code Not applicable. · Transport/Additional information:Not dangerous according to the above specifications. · UN "Model Regulation":- 15Regulatory information · Safety, health and environmental regulations/legislation specific for the substance or mixture · Sara · Section 355 (Extremely hazardous substances): None of the ingredients is listed. · Section 313 (Specific toxic chemical listings): None of the ingredients are listed. · TSCA (Toxic Substances Control Act): All ingredients are listed. · Proposition 65: · Chemicals known to cause cancer: None of the ingredients are listed. · Cancerogenity categories · EPA (Environmental Protection Agency) None of the ingredients is listed. · TLV (Threshold Limit Value established by ACGIH) None of the ingredients is listed. · MAK (German Maximum Workplace Concentration) None of the ingredients is listed. · NIOSH-Ca (National Institute for Occupational Safety and Health) None of the ingredients is listed. · Chemical safety assessment:not required. 16Other information This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship. · Department issuing SDS: Hilti Corporation Business Unit Chemicals Quality/Safety/Environment (Contd. on page 5) US 05/21/2019 Page 5/5 Safety Data Sheet acc. to ISO 11014 Printing date 05/18/2015 Reviewed on 08/18/2014Version number 3 (Contd. of page 4) 40.2.7 FL-9494 Schaan / Liechtenstein chemicals.hse@hilti.com Tel.: +423 234 3004 FAX.: +423 234 3462 · Date of preparation / last revision 05/18/2015 / 2 · Abbreviations and acronyms: ADR: Accord européen sur le transport des marchandises dangereuses par Route (European Agreement concerning the International Carriage of Dangerous Goods by Road) IMDG: International Maritime Code for Dangerous Goods DOT: US Department of Transportation IATA: International Air Transport Association ACGIH: American Conference of Governmental Industrial Hygienists EINECS: European Inventory of Existing Commercial Chemical Substances ELINCS: European List of Notified Chemical Substances CAS: Chemical Abstracts Service (division of the American Chemical Society) · * Data compared to the previous version altered. US 05/21/2019 Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1 -800-879-8000 www.hilti.com August 26, 2015 To Whom It May Concern: Re: CP 643N/644 Firestop Collars – LEED Information Item Numbers: 304325 304326 304328 304329 304331 304341 304344 The Hilti CP 643N/644 Firestop Collars are manufactured in Germany. The Hilti CP 643N/644 Firestop Collars have a VOC content of 7.6 grams/liter. The amount of post-consumer or post-industrial content in CP 643N/644 Firestop Collars is not known. The metal portions of the collars are recyclable. The CP 643N/644 Firestop Collars do not contain any Rapidly Renewable Materials. The CP 643N/644 Firestop Collars are not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Sr. Manager, Safety/Environmental Hilti Inc. (918) 872 3704 jerry.metcalf@hilti.com Rev. Date: 8/14/15 The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America requirements, as those requirements differ. The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced non-catalog Hilti products may have differing manufacturing plant locations. Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates. 05/21/2019 Product information Hilti, Inc. (USA) 1-800-879-8000 I www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca Hilti. Outperform. Outlast. High-performance intumescent firestop sealant FS-ONE MAX Applications ■For effectively sealing most common through penetrations in a variety of base materials ■For use on concrete, masonry and drywall ■Mixed and multiple penetrations ■Metal pipe penetrations: copper, steel and EMT ■Insulated metal pipe penetrations: steel and copper ■Plastic pipe penetrations: closed or vented Advantages ■US-produced: “Buy American” compliant ■One product for a variety of common through penetrations ■Cost-effective, easy-to-use solution ■Water-based and paintable ■Industry-leading VOC results ■Ethylene glycol-free 12 / 1 6 D B S Order Designation Package Content Item number FS-ONE MAX 20oz foil (3 case + disp)1x Foil pack dispenser manual CS 270-P1, 75x Firestop sealant FS-ONE MAX 20 oz foil 3530252 FS-ONE MAX 10oz tube (1 case)12x Firestop sealant FS-ONE MAX 10 oz cartridge 3530249 FS-ONE MAX 5 gallon (18 pails)18x Firestop sealant FS-ONE MAX 5 gallon pail 3530263 FS-ONE MAX 20oz foil (1 case)25x Firestop sealant FS-ONE MAX 20 oz foil 3530250 FS-ONE MAX 20oz foil (3 cases)75x Firestop sealant FS-ONE MAX 20 oz foil 3530251 FS-ONE MAX 20oz Foil-Pallet 600x FSONE-MAX 20 oz foil, 290x Bulk Shipping Condition 3534713 FS-ONE MAX 10 oz cartridge 2101531 FS-ONE MAX 5 gallon pail 2101533 Technical data Chemical basis Water-based acrylic dispersion Approx. Density 84.3 lb/ft³ Color Red Application temperature range 41 - 104 °F Approx. cure time1)4 mm/3 days Temperature resistance range -4 to 212 °F Mold and mildew performance Class 0 (ASTM G21-96) Mold and mildew resistance Yes Surface burning characteristics UL 723 (ASTM E84) Flame spread: 0 Smoke development: 10 Tested in accordance with UL 1479, ASTM E814, ASTM E84, CAN/ ULC-S115, ASTM G21, ASTM E90 California State fire marshal approval CSFM Listing 4485-1200:0108 for FS-ONE MAX Intumescent Firestop Sealant Expansion ratio (unrestricted, up to)1:5 1) at 75°F/24°C, 50% relative humidity Mold and mildew resistant Chemical resistant FILL, VOID OR CAVITY MATERIAL FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 66Y7 05/21/2019 CERTIFICATE OF COMPLIANCE Certificate Number 20150108-R13240 Report Reference R13240 Issue Date 2015-January-08 William R. Carney, Director, North American Certification Programs UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus Page 1 of 1 Issued to: Hilti Construction Chemicals, Div of Hilti Inc. 5400 S 122nd East Ave Tulsa, OK 74146 This is to certify that representative samples of Fill, Void or Cavity Materials Fill, Void or Cavity Materials Certified for Canada FS-ONE MAX Intumescent Sealant for use in Through- Penetration Firestop and Joint Systems in the UL Fire Resistance Directory and in the Products Certified for Canada Directory. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Through-Penetration Firestops," – Edition 4 ANSI/UL 2079, "Tests for Fire Resistance of Building Joint Systems," – Edition 4 – Revision Date 2014/12/17 CAN/ULC-S115, "Standard Method of Fire Tests of Firestop Systems." – Edition 4 – Issue Date 2011/06/01 Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Classification Mark should be considered as being covered by UL’s Classification and Follow-Up Service. The UL Classification Mark includes: UL in a circle: with the word “CLASSIFIED” (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL’s evaluation of the product; and the product category name (product identity) as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product. 05/21/2019 FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations Date of issue: 07/04/2017 Revision date: 07/04/2017 Supersedes: 12/17/2015 Version: 1.3 05/07/2017 US-OSHA - en 1/7 SECTION 1: Identification 1.1. Identification Product form Mixture Name FS-ONE MAX; CFS-FIL Product code BU Fire Protection Chemical structure 1.2. Relevant identified uses of the substance or mixture and uses advised against No additional information available 1.3. Details of the supplier of the safety data sheet Hilti, Inc. Legacy Tower, Suite 1000 75024 Plano - USA T +1 9724035800 1-800-879-8000 toll free - F +1 918 254 0522 Supplier Hilti, Inc. Legacy Tower, Suite 1000 75024 Plano - USA T +1 9724035800 1-800-879-8000 toll free - F +1 918 254 0522 Department issuing data specification sheet Hilti AG Feldkircherstraße 100 9494 Schaan - Liechtenstein T +423 234 2111 chemicals.hse@hilti.com 1.4. Emergency telephone number Emergency number Chem-Trec Tel.: 1 800 424 9300 (USA, PR, Virgin Islands, Canada) Tel.: 703 527 3887 (Other countries) +1 918 8723000 1-800-879-8000 toll free SECTION 2: Hazards identification 2.1. Classification of the substance or mixture GHS-US classification Not classified 2.2. Label elements GHS-US labelling No labelling applicable 2.3. Other hazards No additional information available 2.4. Unknown acute toxicity (GHS US) Not applicable 05/21/2019 FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 05/07/2017 US-OSHA - en 2/7 SECTION 3: Composition/information on ingredients 3.1. Substance Not applicable 3.2. Mixture Name Product identifier % GHS-US classification Quartz (CAS No) 14808-60-7 2.5 - 5 Carc. 1A, H350 Full text of H-statements: see section 16 SECTION 4: First aid measures 4.1. Description of first aid measures First-aid measures after inhalation Get medical advice/attention if you feel unwell. First-aid measures after skin contact Wash skin with plenty of water. If skin irritation occurs: Get medical advice/attention. First-aid measures after eye contact Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention. First-aid measures after ingestion Get medical advice/attention if you feel unwell. 4.2. Most important symptoms and effects, both acute and delayed No additional information available 4.3. Indication of any immediate medical attention and special treatment needed No additional information available SECTION 5: Firefighting measures 5.1. Extinguishing media Suitable extinguishing media Water spray. Dry powder. Foam. Carbon dioxide. 5.2. Special hazards arising from the substance or mixture Reactivity The product is non-reactive under normal conditions of use, storage and transport. 5.3. Advice for firefighters Protection during firefighting Self-contained breathing apparatus. Complete protective clothing. SECTION 6: Accidental release measures 6.1. Personal precautions, protective equipment and emergency procedures 6.1.1. For non-emergency personnel No additional information available 6.1.2. For emergency responders Protective equipment For further information refer to section 8: "Exposure controls/personal protection". 6.2. Environmental precautions No additional information available 6.3. Methods and material for containment and cleaning up Methods for cleaning up Mechanically recover the product. 6.4. Reference to other sections For further information refer to section 13. 05/21/2019 FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 05/07/2017 US-OSHA - en 3/7 SECTION 7: Handling and storage 7.1. Precautions for safe handling Precautions for safe handling Wear personal protective equipment. Hygiene measures Wash contaminated clothing before reuse. Do not eat, drink or smoke when using this product. Always wash hands after handling the product. 7.2. Conditions for safe storage, including any incompatibilities Storage conditions Keep cool. Store in a dry place. Storage temperature 41 - 77 °F SECTION 8: Exposure controls/personal protection 8.1. Control parameters Quartz (14808-60-7) OSHA Remark (OSHA) (3) See Table Z-3. Additional information The product has a pasty consistency. Exposure limit values for respirable dusts are not relevant for this product 8.2. Exposure controls Personal protective equipment Protective clothing. Safety glasses. Gloves. Hand protection Protective gloves. EN 374. Eye protection Chemical goggles or safety glasses. Skin and body protection Wear suitable protective clothing. SECTION 9: Physical and chemical properties 9.1. Information on basic physical and chemical properties Physical state Liquid Appearance Pasty. Colour red Odour characteristic Odour threshold Not determined pH ≈ 7.85 Melting point Not applicable Freezing point No data available Boiling point No data available Flash point Not applicable Relative evaporation rate (butylacetate=1) No data available Flammability (solid, gas) No data available Explosive limits No data available Explosive properties No data available Oxidising properties No data available Vapour pressure No data available Relative density No data available Relative vapour density at 20 °C No data available 05/21/2019 FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 05/07/2017 US-OSHA - en 4/7 Density ≈ 1.35 g/cm³ Molecular mass Not determined Solubility No data available Log Pow No data available Auto-ignition temperature No data available Decomposition temperature No data available Viscosity No data available Viscosity, kinematic No data available Viscosity, dynamic No data available 9.2. Other information VOC content 9 g/l SECTION 10: Stability and reactivity 10.1. Reactivity The product is non-reactive under normal conditions of use, storage and transport. 10.2. Chemical stability Stable under normal conditions. 10.3. Possibility of hazardous reactions No dangerous reactions known under normal conditions of use. 10.4. Conditions to avoid None under recommended storage and handling conditions (see section 7). 10.5. Incompatible materials No additional information available 10.6. Hazardous decomposition products Under normal conditions of storage and use, hazardous decomposition products should not be produced. SECTION 11: Toxicological information 11.1. Information on toxicological effects Acute toxicity Not classified Skin corrosion/irritation Not classified pH: ≈ 7.85 Serious eye damage/irritation Not classified pH: ≈ 7.85 Respiratory or skin sensitisation Not classified Germ cell mutagenicity Not classified Carcinogenicity Not classified Quartz (14808-60-7) IARC group 1 - Carcinogenic to humans Reproductive toxicity Not classified Specific target organ toxicity (single exposure) Not classified Specific target organ toxicity (repeated exposure) Not classified 05/21/2019 FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 05/07/2017 US-OSHA - en 5/7 Aspiration hazard Not classified SECTION 12: Ecological information 12.1. Toxicity Ecology - general The product is not considered harmful to aquatic organisms nor to cause long-term adverse effects in the environment. 12.2. Persistence and degradability No additional information available 12.3. Bioaccumulative potential No additional information available 12.4. Mobility in soil No additional information available 12.5. Other adverse effects Effect on the global warming No known effects from this product. SECTION 13: Disposal considerations 13.1. Waste treatment methods Waste treatment methods Dispose of contents/container in accordance with licensed collector’s sorting instructions. Waste disposal recommendations Dispose in a safe manner in accordance with local/national regulations. SECTION 14: Transport information In accordance with ADR / RID / IMDG / IATA / ADN ADR IMDG IATA RID 14.1. UN number Not regulated for transport 14.2. UN proper shipping name Not applicable Not applicable Not applicable Not applicable 14.3. Transport hazard class(es) Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable Not applicable 14.4. Packing group Not applicable Not applicable Not applicable Not applicable 14.5. Environmental hazards Dangerous for the environment : No Dangerous for the environment : No Marine pollutant : No Dangerous for the environment : No Dangerous for the environment : No No supplementary information available 05/21/2019 FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 05/07/2017 US-OSHA - en 6/7 14.6. Special precautions for user - Overland transport - Transport by sea No data available - Air transport No data available - Rail transport Carriage prohibited (RID) No 14.7. Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code SECTION 15: Regulatory information 15.1. US Federal regulations All components of this product are listed, or excluded from listing, on the United States Environmental Protection Agency Toxic Substances Control Act (TSCA) inventory 15.2. International regulations CANADA FS-ONE MAX; CFS-FIL WHMIS Classification Uncontrolled product according to WHMIS classification criteria EU-Regulations No additional information available Classification according to Regulation (EC) No. 1272/2008 [CLP] Not classified National regulations Quartz (14808-60-7) Listed on IARC (International Agency for Research on Cancer) 15.3. US State regulations California Proposition 65 - This product does not contain any substances known to the state of California to cause cancer, developmental and/or reproductive harm SECTION 16: Other information Revision date 07/04/2017 Full text of H-statements: ------ H350 May cause cancer 05/21/2019 FS-ONE MAX; CFS-FIL Safety Data Sheet according to Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules and Regulations 05/07/2017 US-OSHA - en 7/7 NFPA health hazard 0 - Materials that, under emergency conditions, would offer no hazard beyond that of ordinary combustible materials. NFPA fire hazard 0 - Materials that will not burn under typical dire conditions, including intrinsically noncombustible materials such as concrete, stone, and sand. NFPA reactivity 0 - Material that in themselves are normally stable, even under fire conditions. Hazard Rating Health 0 Minimal Hazard - No significant risk to health Flammability 0 Minimal Hazard - Materials that will not burn Physical 0 Minimal Hazard - Materials that are normally stable, even under fire conditions, and will NOT react with water, polymerize, decompose, condense, or self-react. Non-Explosives. Personal protection B B - Safety glasses, Gloves SDS_US_Hilti This information is based on our current knowledge and is intended to describe the product for the purposes of health, safety and environmental requirements only. It should not therefore be construed as guaranteeing any specific property of the product 05/21/2019 Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1 -800-879-8000 www.hilti.com August 26, 2015 To Whom It May Concern: Re: Hilti FS-ONE Max Firestop – LEED Info. Item Numbers: 2101531 2101532 2101533 The Hilti FS-ONE MAX Firestop is manufactured in the United States There is no post-consumer or post-industrial content in FS-ONE MAX and it cannot be recycled. The VOC content for FS-ONE MAX is 9 grams/liter. FS-ONE MAX is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non- regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Sr. Manager, Safety/Environmental Hilti Inc (918) 872 3704 jerry.metcalf@hilti.com Rev. Date: 7/31/15 The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America requirements, as those requirements differ. The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced non-catalog Hilti products may have differing manufacturing plant locations. Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates. 05/21/2019 Thermafiber® Safing™Fire Containment Insulation Exceptional performance in Perimeter Fire Containment Systems Provides life saving fire protection in rated assemblies Fire resistant to temperatures above 2,000°F (1,093°C) Easy to fabricate for through penetrations and firestopping Conserves energy, reduces greenhouse gas emissions Resists moisture Controls noise and sound + + + + + + + Thermafiber Safing and FireSpan® insulation provide the critical components of the perimeter fire containment system in the 111 South Wacker Building in Chicago, IL. Thermafiber insulation also contributed to the building’s LEED® Gold Rating. Thermafiber® SafingTM is compression fitted between FireSpan® insulation and the concrete slab edge to create a perimeter fire containment system. LEED® v2009 Green Building Credits Energy & Atmosphere Materials & Resources Indoor Environmental Quality Innovation in Design 1 2.1, 2.2 9 1 4.1, 4.2 5.1, 5.2 Minimum70% Recycled Content1 05/21/2019 Thermafiber® SafingTM Insulation Description: Thermafiber® Insolutions®: For Further Information: Notice: Submittal Approvals: THERMAFIBER SafingTM products are designed to provide life saving fire protection in perimeter fire containment systems, floor and wall penetrations, construction joints, and other firestopping applications. These products are noncombustible, moisture-resistant, noncorrosive, nondeteriorating, mildew-proof and vermin-proof. Thermafiber Safing provides thermal insulation, fire protection, and acoustical control in many different UL and Intertek (formerly OPL) listed fire containment assemblies of 1, 2, and 3-hr ratings. Thermafiber offers industry leading technical and engineering assistance to architects, specifiers, and contractors. These services include CAD drawings, engineering judgments, LEED® Credit Information, product recommendations, and customized products. Contact our technical services department at 1-888-834-2371, or email technicalservice@owenscorning.com For additional information about these or other Thermafiber products contact us at 1-888-834-2371 or visit our website www.thermafiber.com. THERMAFIBER, Inc. shall not be liable for incidental and consequential damages, directly or indirectly sustained, nor for any loss caused by application of these goods not in accordance with current printed instructions or for other than the intended use. THERMAFIBER liability is expressly limited to replacement of defective goods. Any claim shall be deemed waived unless made in writing within thirty (30) days from date it was or reasonably should have been discovered. Job Name Contractor Date 3711 Mill Street | Wabash, IN 46992 | 888-TFIBER1 [834-2371] | [260] 563-2111 | www.thermafiber.com Standard Sizes: Standards Compliance:SafingTM Insulation meets the following: ASTM C 665 Non-corrosive, Type I, III ASTM C 612 Type IA, IB, II ASTM E 136 Rated Non-combustible per NFPA Standard 220 CAN/ULC S114 Complies ASTM E 96 Unfaced, 50 Perms as tested ASTM E 96 Foil Faced, 0.02 Perms as tested ASTM C 1104 Absorbs less than 1% by volume CAN/ULC S102 Flame Spread 0, Smoke Developed 0 ASTM E 814 or UL 1479 Safing Insulation used in conjunction with an approved fill, void, or cavity material sealant or other approved material in through – penetration firestop systems - Complies UL 2079 Safing Insulation used in conjunction with an approved fill, void or cavity material in construction joint systems - Complies CAN/ULC S115 Complies Safing products are approved by: New York City Board of Standards & Appeals – (under BSA 39-74-SM & accepted by MEA-209-82-M, Vol. 4). Thickness* Widths** Lengths** Safing 4.0 pcf 1”- 7” 16”, 24”, 36” 48”, 60” Safing 6.0 pcf 1”- 7” 16”, 24”, 36” 48”, 60” Tolerances +1/4” - 1/8” ±1/8” ±1/2” *Thicknesses are available in ½” increments. **Custom sizes are available upon request. Product Options:• Safing 4.0 pcf, 2” or greater thickness, is available with or without a vapor retarding foil facing. • Safing 6.0 pcf, 1.5” or greater thickness, is available with or without a vapor retarding foil facing. • Recycled Content Options1: EPA Choice Fiber (US Government Buildings) ........Minimum 75% Standard Fiber ....................................................................70% 1Recycled content options other than Standard must be specified at time of order. Installation:All firestopping insulation should be installed per the architectural specification or system specific test description. All compressed Safing insulation should be installed per the listed assembly. • Perimeter Installation: SafingTM insulation should be compression fitted between the slab edge and the FireSpan curtain wall insulation, leaving no voids. • Penetration Application: Safing insulation should be cut slightly larger than the opening and compression fitted into the opening, leaving no voids. • Construction Joint Application: Safing insulation should be compression fitted into the joint opening, leaving no voids. Technical Data: TF 6 1 2 / R e v 0 3 - 1 5 C o p y r i g h t 2 0 1 5 , T h e r m a f i b e r , I n c . Al l R i g h t s R e s e r v e d . L E E D ® is a r e g i s t e r e d t r a d e m a r k o f U . S . G r e e n B u i l d i n g C o u n c i l . SafingTM insulation is a critical component of any perimeter fire containment system. Thermafiber® has performed decades of testing in all of the containment systems listed below. For more complete test information, see SA707, THERMAFIBER Life-Safety Fire Containment Systems technical catalog or UL® and Intertek® (formerly OPL) Directories. For a full listing of containment systems visit www.thermafiber.com and click on Fire Rated Assemblies. UL Reference = TYPE SAF • Aluminum Spandrel Curtain Wall Fire Containment • Steel Stud-Framed/Gypsum Sheathing Curtain Wall Fire Containment • Glass Spandrel Curtain Wall Fire Containment • Granite Spandrel Curtain Wall Fire Containment • Precast Concrete Spandrel Fire-Containment Tests Per ASTM E 2307 Product Actual “k” @ 75° [24°C] “R” value per Designation Density inch of thickness*** Safing 4.0 pcf 0.24 ‘R’= 4.2 0 0 25 0 Safing 6.0 pcf 0.24 ‘R’= 4.2 0 0 25 0 BTU.in/hr.sq. ft. °F Tested to ASTM C 518 Tested to ASTM E 84 Unfaced Foil Faced Flame Spread Flame Spread Smoke Developed Smoke Developed ***R = thickness divided by ‘k’ 05/21/2019 CERTIFICATE OF COMPLIANCE Certificate Number 20151218-R10905 Report Reference R10905 Issue Date 2015-December-18 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 1 of 3 Issued to: Thermafiber Inc. 3711 Mill St Wabash, IN 46992 USA This is to certify that representative samples of Forming Materials Forming Materials Certified for Canada Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 1479, "Fire Tests of Through-Penetration Firestops," ANSI/UL 2079, "Tests for Fire Resistance of Building Joint Systems," and ANSI/ASTM E2307 (2010), "Standard Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale, Multi-story Test Apparatus." CAN/ULC-S115 (2005), "Standard Method of Fire Tests of Firestop Systems." Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. 05/21/2019 CERTIFICATE OF COMPLIANCE Certificate Number 20151218-R10905 Report Reference R10905 Issue Date 2015-December-18 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 2 of 3 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Type SAF mineral wool batts for use in Joint System Nos. BW-S-0029, FF-D-0002, FF-D-0011, FF-D-0013, FF-D-0014, FF-D-0015, FF-D-0016, FF-D-0017, FF-D-0019, FF-D-0022, FF-D-0023, FF-D-0025, FF-D-0026, FF-D-0028, FF-D-0073, FF-D-0074, FF-D-0096, FF-D-0097, FF-D-0109, FF-D-1001, FF-D-1002, FF-D-1003, FF-D-1004, FF-D-1006, FF-D-1007, FF-D-1008, FF-D-1010, FF-D-1015, FF-D-1016, FF-D-1020, FF-D-1021, FF-D-1024, FF-D-1025, FF-D-1027, FF-D-1036, FF-D-1039, FF-D-1040, FF-D-1041, FF-D-1042, FF-D-1045, FF-D-1047, FF-D-1098, FF-D-1125, FF-D-1158, FF-D-3003, FF-D-3004, FF-S-1031, FF-S-1033, FW-D-0001, FW-D-0004, FW-D-0007, FW-D-0009, FW-D-0010, FW-D-0011, FW-D-0012, FW-D-0014, FW-D-0017, FW-D-0018, FW-D-0020, FW-D-0021, FW-D-0023, FW-D-0024, FW-D-0027, FW-D-0050, FW-D-0051, FW-D-0067, FW-D-0068, FW-D-1001, FW-D-1002, FW-D-1003, FW-D-1005, FW-D-1006, FW-D-1007, FW-D-1009, FW-D-1010, FW-D-1016, FW-D-1017, FW-D-1020, FW-D-1024, FW-D-1033, FW-D-1035, FW-D-1037, FW-D-1038, FW-D-1039, FW-D-1040, FW-D-1044, FW-D-1047, FW-D-1055, FW-D-1070, FW-D-1089, FW-D-1092, FW-D-1093, FW-D-1102, FW-D-1103 FW-S-1016, FW-S-1019, HW-D-0001, HW-D-0002, HW-D-0006, HW-D-0009, HW-D-0013, HW-D-0016, HW-D-0017, HW-D-0020, HW-D-0021, HW-D-0022, HW-D-0023, HW-D-0025, HW-D-0026, HW-D-0027, HW-D-0028, HW-D-0029, HW-D-0030, HW-D-0031, HW-D-0034, HW-D-0038, HW-D-0039, HW-D-0040, HW-D-0042, HW-D-0043, HW-D-0044, HW-D-0045, HW-D-0046, HW-D-0047, HW-D-0049, HW-D-0050, HW-D-0051, HW-D-0052, HW-D-0054, HW-D-0055, HW-D-0058, HW-D-0059, HW-D-0062, HW-D-0064, HW-D-0067, HW-D-0069, HW-D-0072, HW-D-0073, HW-D-0075, HW-D-0079, HW-D-0086, HW-D-0087, HW-D-0088, HW-D-0089, HW-D-0091, HW-D-0092, HW-D-0099, HW-D-0100, HW-D-0101, HW-D-0102, HW-D-0103, HW-D-0104, HW-D-0105, HW-D-0106, HW-D-0107, HW-D-0108, HW-D-0118, HW-D-0122, HW-D-0123, HW-D-0127, HW-D-0128, HW-D-0131, HW-D-0136, HW-D-0137, HW-D-0139, HW-D-0140, HW-D-0143, HW-D-0146, HW-D-0149, HW-D-0152, HW-D-0153, HW-D-0154, HW-D-0156, HW-D-0157, HW-D-0160, HW-D-0166, HW-D-0168, HW-D-0170, HW-D-0171, HW-D-0172, HW-D-0173, HW-D-0174, HW-D-0177, HW-D-0178, HW-D-0185, HW-D-0186, HW-D-0187, HW-D-0188, HW-D-0190, HW-D-0192, HW-D-0199, HW-D-0200, HW-D-0201, HW-D-0204, HW-D-0205, HW-D-0206, HW-D-0208, HW-D-0211, HW-D-0218, HW-D-0220, HW-D-0221, HW-D-0222, HW-D-0246, HW-D-0248, HW-D-0252, HW-D-0253, HW-D-0258, HW-D-0259, HW-D-0263, HW-D-0265, HW-D-0278, HW-D-0279, HW-D-0297, HW-D-0298, HW-D-0299, HW-D-0335, HW-D-0336, HW-D-0337, HW-D-0338, HW-D-0354, HW-D-0357, HW-D-0358, HW-D-0359, HW-D-0363, HW-D-0365, HW-D-0366, HW-D-0367, HW-D-0377, HW-D-0378, HW-D-0380, HW-D-0381, HW-D-0384, HW-D-0385, HW-D-0388, HW-D-0389, HW-D-0391, HW-D-0395, HW-D-0396, HW-D-0404, HW-D-0405, HW-D-0406, HW-D-0407, HW-D-0408, HW-D-0409, HW-D-0410, HW-D-0411, HW-D-0412, HW-D-0413, HW-D-0414, HW-D-0415, HW-D-0416, HW-D-0417, HW-D-0441, HW-D-0442, HW-D-0447, HW-D-0456, HW-D-0457, HW-D-0460, HW-D-0465, HW-D-0467, HW-D-0468, HW-D-0478, HW-D-0479, HW-D-0524, HW-D-0531, HW-D-0536, HW-D-0538, HW-D-0539, HW-D-0540, HW-D-0542, HW-D-0546, HW-D-0547, HW-D-0548, HW-D-0549, HW-D-0553, HW-D-0560, HW-D-0561, HW-D-0562, HW-D-0564, HW-D-0566, HW-D-0567, HW-D-0568, HW-D-0569, HW-D-0570, HW-D-0571, HW-D-0572, HW-D-0577, HW-D-0578, HW-D-0580, 05/21/2019 CERTIFICATE OF COMPLIANCE Certificate Number 20151218-R10905 Report Reference R10905 Issue Date 2015-December-18 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 3 of 3 Type SAF mineral wool batts for use in Joint System Nos. HW-D-0582, HW-D-0583, HW-D-0584, HW-D-0590, HW-D-0591, HW-D-0597, HW-D-0612, HW-D-0614, HW-D-0617, HW-D-0619, HW-D-0631, HW-D-0633, HW-D-0634, HW-D-0635, HW-D-0636, HW-D-0639, HW-D-0640, HW-D-0642, HW-D-0643, HW-D-0644, HW-D-0645, HW-D-0649, HW-D-0650, HW-D-0661, HW-D-0662, HW-D-0687, HW-D-0697, HW-D-0698, HW-D-0702, HW-D-0703, HW-D-0704, HW-D-0725, HW-D-0726, HW-D-0735, HW-D-0740, HW-D-0741, HW-D-0742, HW-D-0743, HW-D-0747, HW-D-0748, HW-D-0750, HW-D-1001, HW-D-1002, HW-D-1003, HW-D-1004, HW-D-1005, HW-D-1006, HW-D-1007, HW-D-1010, HW-D-1013, HW-D-1014, HW-D-1015, HW-D-1016, HW-D-1020, HW-D-1021, HW-D-1022, HW-D-1023, HW-D-1024, HW-D-1028, HW-D-1032, HW-D-1033, HW-D-1034, HW-D-1037, HW-D-1040, HW-D-1042, HW-D-1044, HW-D-1045, HW-D-1050, HW-D-1060, HW-D-1066, HW-D-1067, HW-D-1068, HW-D-1069, HW-D-1070, HW-D-1073, HW-D-1074, HW-D-1075, HW-D-1076, HW-D-1077, HW-D-1079, HW-D-1080, HW-D-1089, HW-D-1094, HW-D-1097, HW-D-1102, HW-D-1103, HW-D-1104, HW-D-1110, HW-S-0001, HW-S-0009, HW-S-0010, HW-S-0053, HW-S-0054, HW-S-0080, HW-S-0083, HW-S-1015, WW-D-0013, WW-D-0018, WW-D-0019, WW-D-0020, WW-D-0063, WW-D-1001, WW-D-1002, WW-D-0022, WW-D-0089, WW-D-0090, WW-D-0103, WW-D-0171, WW-D-0140, WW-D-0141, WW-D-1003, WW-D-1004, WW-D-1005, WW-D-1006, WW-D-1007, WW-D-1010, WW-D-1015, WW-D-1016, WW-D-1023, WW-D-1027, WW-D-1036, WW-D-1037, WW-D-1042, WW-D-1047, WW-D-1089, WW-D-1090, WW-D-1091, WW-D-1128, WW-D-1129, WW-S-0064, WW-S-1035. TYPE SAF MINERAL WOOL BATTS FOR USE IN PERIMETER FIRE CONTAINMENT SYSTEM NOS. CW-D-1001, CW-D-1002, CW-D-1003, CW-D-1004, CW-D-1005, CW-D-1006, CW-D-1007, CW-D-1008, CW-D-1009, CW-D-1010, CW-D-1011, CW-D-1012, CW-D-1013, CW-D-1014, CW-D-1015, CW-D-1016, CW-D-1017, CW-D-1018, CW-D-1019, CW-D-1020, CW-D-1021, CW-D-1022, CW-D-1023, CW-D-1028, CW-D-1029, CW-D-1030, CW-D-2001, CW-D-2002, CW-D-2003, CW-D-2005, CW-D-2006, CW-D-2008, CW-D-2009, CW-D-2010, CW-D-2011, CW-D-2012, CW-D-2013, CW-D-2036, CW-D-2037, CW-D-2038, CW-D-2039, CW-D-2040, CW-D-2041, CW-D-2042, CW-D-2046, CW-D-2047, CW-D-2048, CW-D-2049, CW-D-2050, CW-D-2051, CW-D-2052, CW-D-2055, CW-D-2056, CW-D-2057, CW-D-2058, CW-D-2059, CW-D-2063, CW-D-2064, CW-D-2065, CW-D-2066, CW-S-0001, CW-S-0002, CW-S-0003, CW-S-0004, CW-S-1001, CW-S-1002, CW-S-1003, CW-S-1007, CW-S-1010, CW-S-1016, CW-S-1017, CW-S-1020, CW-S-1022, CW-S-1023, CW-S-1024, CW-S-1025, CW-S-1026, CW-S-2001, CW-S-2002, CW-S-2003, CW-S-2006, CW-S-2008, CW-S-2014, CW-S-2021, CW-S-2022, CW-S-2023, CW-S-2025, CW-S-2029, CW-S-2034, CW-S-2035, CW-S-2036, CW-S-2058, CW-S-2059, CW-S-2060, CW-S-2061, CW-S-2062, CW-S-2064, CW-S-2065, CW-S-2066. TYPE SAF MINERAL WOOL BATTS FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEM NOS. C-AJ-1020, C-AJ-1081, C-AJ-3045, W-L-1027, W-L-1039, W-L-1064, W-L-1065, W-L-2023, W-L-2036, W-L-3023, W-L-3034, W-L-7001, W-L-7002. TOPSTOP MINERAL WOOL DECK PLUGS TYPE SAF BATTS FOR USE IN JOINT SYSTEM NOS. HW-D-0001, HW-D-0002, HW-D-0020, HW-D-0022, HW-D-0034, HW-D-0039, HW-D-0043, HW-D-0086, HW-D-0088, HW-D-0160, HW-D-0161, HW-D-0456, HW-D-0612, HW-D-0644. 05/21/2019 Hilti, Inc. 5400 South 122nd East Avenue Tulsa, OK 74146 1-800-879-8000 www.hilti.com September 24, 2015 To Whom It May Concern: Re: Hilti Mineral Wool-LEED Information Item Number: 236993 The Hilti Mineral Wool is manufactured in Wabash, Indiana. The post-consumer recycled content in the Hilti Mineral Wool is 0%. The pre-consumer recycled content in the Hilti Mineral Wool is 90%. There is no detectable VOC content in this product. Hilti Mineral Wool is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non- regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 872-3704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Sr. Manager, Safety/Environmental Hilti Inc. 918 872 3704 jerry.metcalf@hilti.com Rev. Date: 9/24/15 The manufacturing plant location on this certificate has been provided for LEEDS reporting purposes only. It should never be used for Country of Origin certification or a representation of compliance/non-compliance with Buy American or Buy America requirements, as those requirements differ. The manufacturing plant location(s) identified on the certificate represent standard Hilti catalog products only. “Specially” produced non-catalog Hilti products may have differing manufacturing plant locations. Contact your Hilti representative in cases of “specially” produced products for a custom LEEDS certificates. 05/21/2019