HomeMy WebLinkAboutFile Documents.533 W Hallam St.0285.2018 (108).ARBK aec
Architectural Engineering Consultants, Inc.
Mechanical, Electrical, & Lighting Design Services
An Office with LEEDTTMM Accredited Professionals
40801 US Hwy 6 & 24, Suite 214, Eagle-Vail, CO 81620 Post Office Box 8489, Avon, CO 81620
phone: 970-748-8520 email: stan@aec-vail.com web: www.aec-vail.com
The linked image cannot be displayed. The
file may have been moved, renamed, or
deleted. Verify that the link points to the
correct file and location.
November 19, 2018
William Luis
Poss Architecture & Planning
605 East Main Street,
Aspen, CO 81611
Re: Duncan Ski Haus,
Dear William,
This document is intended to show compliance of the addition & remodel of the residence located at 533
West Hallam, Aspen in Pitkin County, Colorado with the 2015 International Energy Conservation Code
(2015 IECC). We propose to use a prescriptive approach per sections 402.1-402.3 and 403.2.1 of the
2015 IECC. I have also included the inspection checklist from the 2015 IECC Rescheck program for your
use.
Project
The project at 533 West Hallam is an addition & remodel of a residence with a floor area of
approximately 3,740 sf. The heat load calculations are performed using the Carrier Hourly Analysis
Program and provides a more detailed and accurate load than Manual J. A dewpoint calculation is not
included in these permit documents, as the roof assembly meets the requirements of section R806.5 of
the 2015 IRC.
Building Envelope
The following table lists the mandatory minimum insulation and fenestration requirements for the project
climate zone (7). All new assemblies will meet the following requirements.
Fenestration
U-factor
Skylight
U-factor
Ceiling
R-value
Wood frame
wall R-value
Floor
R-value
Basement
wall R-value
Slab
R-value
Crawl Wall
R-value
Code
Minimums
0.28 (1) 0.55(1) 49 20+5 (6) 38 (2) 15/19 (3) 10 (4) 15/19 (5)
Notes: 1) Fenestration SHGC requirements do not apply in climate zone (7)
2) Or insulation sufficient to fill the framing cavity, R-19 minimum
3) R-15 continuous insulation on the interior or exterior or R-19 cavity insulation on the interior of the
basement wall. Can be satisfied with R-13 cavity plus R-5 continuous.
4) 4 ft deep and R-15 edge insulation for heated slabs
5) R-15 continuous insulation or R-19 cavity insulation.
6) All alterations that expose a framing cavity will have the cavity filled with insulation per R503.1.1
Sincerely,
Bryan Urban, EIT
12/04/2018
OUTDOOR TEMPERATURE -15 °F OUTDOOR TEMPERATURE 88 °F
INDOOR TEMPERATURE 72 °F INDOOR TEMPERATURE 75 °F
TOTAL HEAT LOSS 89,782 BTU/HR SENSIBLE HEAT GAIN 85,380 BTU/HR
LATENT HEAT GAIN 4,938 BTU/HR
TOTAL HEAT GAIN 90,318 BTU/HR
MANUAL J DESIGN CONDITIONS
WINTER DESIGN CONDITIONS SUMMER DESIGN CONDITIONS
12/04/2018
Zone Sizing Summary for Manual J
Project Name: 18032 - Duncan Skihaus 11/19/2018
Prepared by: AEC 01:39PM
Air System Information
Air System Name Manual J
Equipment Class UNDEF
Air System Type SZCAV
Number of zones 1
Floor Area 6095.0 ft²
Location Eagle, Colorado
Sizing Calculation Information
Zone and Space Sizing Method:
Zone CFM Sum of space airflow rates
Space CFM Individual peak space loads
Calculation Months Jan to Dec
Sizing Data Calculated
Zone Sizing Data
Maximum Design Minimum Time Maximum Zone
Cooling Air Air of Heating Floor
Sensible Flow Flow Peak Load Area Zone
Zone Name (MBH)(CFM)(CFM)Load (MBH)(ft²)CFM/ft²
Zone 1 79.2 6078 6078 Jul 1600 89.8 6095.0 1.00
Zone Terminal Sizing Data
No Zone Terminal Sizing Data required for this system.
Space Loads and Airflows
Cooling Time Air Heating Floor
Zone Name / Sensible of Flow Load Area Space
Space Name Mult.(MBH)Load (CFM)(MBH)(ft²)CFM/ft²
Zone 1
001 FAMILY RM 1 5.4 Jul 1500 399 3.0 685.0 0.58
002 PWDR 1 0.2 Jul 1500 17 0.2 35.0 0.48
004 STO 1 0.0 Jul 1500 6 0.1 30.0 0.22
005 LAUNDRY 1 0.6 Jul 1500 71 1.4 135.0 0.53
010 BEDROOM 1 1 2.7 Jul 1700 197 3.7 285.0 0.69
012 CLO 1 0.3 Jul 1500 27 0.5 65.0 0.42
013 BATH 1 1 0.9 Jul 1500 63 1.1 130.0 0.48
020 BEDROOM 2 1 2.3 Jul 1500 177 3.5 345.0 0.51
021 DRESS 1 0.2 Jul 1500 17 0.2 50.0 0.34
023 BATH 2 1 0.8 Jul 1500 58 1.0 120.0 0.48
030 BEDROOM 3 1 2.9 Jul 1700 216 4.3 345.0 0.63
031 DRESS 1 0.3 Jul 1500 39 0.8 65.0 0.61
033 BATH 1 0.9 Jul 1500 63 1.1 130.0 0.48
040 BEDROOM 4 1 2.2 Jul 1500 180 3.6 320.0 0.56
042 BATH 4 1 0.9 Jul 1500 72 1.4 140.0 0.51
101 ENTRY 1 4.9 Aug 1500 362 4.0 250.0 1.45
102 CAS DINING 1 6.5 Jul 1600 476 6.5 220.0 2.17
102 MUD 1 1.7 Jul 1700 121 2.4 135.0 0.90
103 GARAGE 1 4.2 Aug 1600 370 7.4 475.0 0.78
105 PWDR 1 0.5 Aug 1500 33 0.6 45.0 0.73
106 LIVING 1 8.3 Jul 1700 608 5.6 375.0 1.62
107 KITCHEN 1 3.2 Jul 1600 237 2.4 260.0 0.91
108 PANTRY 1 1.6 Jul 1600 118 0.6 40.0 2.96
111 ENTRY 1 5.0 Aug 1500 367 6.1 140.0 2.62
113 DINING 1 6.5 Jul 1500 476 7.9 295.0 1.61
114 OFFICE 1 5.4 Jul 1600 397 5.6 130.0 3.06
201 STAIR 1 1.4 Aug 1500 104 1.4 150.0 0.69
202 STORAGE 1 0.4 Jul 1500 84 1.7 150.0 0.56
203 MSTR BDRM 1 5.8 Aug 1600 429 6.8 325.0 1.32
207 MSTR BATH 1 4.0 Jul 1700 294 4.7 225.0 1.31
Hourly Analysis Program v4.50 Page 1 of 1
12/04/2018
aec
Architectural Engineering Consultants, Inc.
Mechanical, Electrical, & Lighting Design Services
An Office with LEED TM Accredited Professionals
Warm Roof Assembly Worksheet Project:
AEC Project Number:
Date:
Calculated By:
Thermal Resistance of Assembly - R-1
Thickness Component R-Value
Outside air Layer 0.17
3" Pavers 0.44
2" Sand 1.16
3" Rigid Insulation 15
Varies Water-proof Membrane 0.2
8" Concrete 0.48
6" Spray Foam Insulation 44
5/8" Gypsum Board 0.56
Inside Air Layer 0.65
Rext 61.45
Rtotal 62.66
Rext R Value of the Exterior Sheating
Rtotal R Value of the Total Roof Assembly
Tin Interior Temperature (70°)
Tout Exterior Temperature (Assuming 19.8° Mean Daily Temperature for Eagle)
Tinterface Temperature at the Rigid/Batt Insulation Interface
Tinterface Rext / Rtotal * (Tin - Tout) + Tout
Tinterface 61.45 62.66 70 19.8 19.8
Tinterface 69.0 °F
Dewpoint at 30 % Relative Humidity 37°F
Dewpoint at 35 % Relative Humidity 41°F
The temperature of the spray foam/gyp board insulation interface is 69°F. Therefore, the resulting dew point of 41°F
would occur in the exterior rigid insulation, which verifies compliance.
Duncan Ski Haus
18032
11/26/2018
Bryan Urban
12/04/2018
aec
Architectural Engineering Consultants, Inc.
Mechanical, Electrical, & Lighting Design Services
An Office with LEED TM Accredited Professionals
Warm Roof Assembly Worksheet Project:
AEC Project Number:
Date:
Calculated By:
Thermal Resistance of Assembly - R-2
Thickness Component R-Value
Outside air Layer 0.17
Varies Cedar Shingles 0.97
Varies Water-proof Membrane 0.2
5/8" Sheathing 0.77
6" Spray Foam Insulation 49
5/8" Gypsum Board 0.56
Inside Air Layer 0.65
Rext 51.11
Rtotal 52.32
Rext R Value of the Exterior Sheating
Rtotal R Value of the Total Roof Assembly
Tin Interior Temperature (70°)
Tout Exterior Temperature (Assuming 19.8° Mean Daily Temperature for Eagle)
Tinterface Temperature at the Rigid/Batt Insulation Interface
Tinterface Rext / Rtotal * (Tin - Tout) + Tout
Tinterface 51.11 52.32 70 19.8 19.8
Tinterface 68.8 °F
Dewpoint at 30 % Relative Humidity 37°F
Dewpoint at 35 % Relative Humidity 41°F
The temperature of the spray foam/gyp board insulation interface is 68.8°F. Therefore, the resulting dew point of 41°F
would occur in the exterior rigid insulation, which verifies compliance.
Duncan Ski Haus
18032
11/26/2018
Bryan Urban
12/04/2018
aec
Architectural Engineering Consultants, Inc.
Mechanical, Electrical, & Lighting Design Services
An Office with LEED TM Accredited Professionals
Warm Roof Assembly Worksheet Project:
AEC Project Number:
Date:
Calculated By:
Thermal Resistance of Assembly - R-3
Thickness Component R-Value
Outside air Layer 0.17
Varies Water-proof Membrane 0.2
1/2" Firestone Isoguard 2.5
4" Rigid Insulation 5
6" Spray Foam Insulation 44
5/8" Gypsum Board 0.56
Inside Air Layer 0.65
Rext 51.87
Rtotal 53.08
Rext R Value of the Exterior Sheating
Rtotal R Value of the Total Roof Assembly
Tin Interior Temperature (70°)
Tout Exterior Temperature (Assuming 19.8° Mean Daily Temperature for Eagle)
Tinterface Temperature at the Rigid/Batt Insulation Interface
Tinterface Rext / Rtotal * (Tin - Tout) + Tout
Tinterface 51.87 53.08 70 19.8 19.8
Tinterface 68.9 °F
Dewpoint at 30 % Relative Humidity 37°F
Dewpoint at 35 % Relative Humidity 41°F
The temperature of the spray foam/gyp board insulation interface is 68.9°F. Therefore, the resulting dew point of 41°F
would occur in the exterior rigid insulation, which verifies compliance.
Duncan Ski Haus
18032
11/26/2018
Bryan Urban
12/04/2018
12/04/2018
12/04/2018
12/04/2018
12/04/2018