HomeMy WebLinkAboutFile Documents.232 E Main St.0132.2018 (105).ACBKCOMcheck Software Version 4.1.1.0 Envelope Compliance Certificate Project Title: 2015 IECC Project Type:New Construction Permit Date:1/2018 Vertical Glazing / Wall Area:29% Location:Aspen, Colorado Climate Zone:7 Construction Site: 232 E. MAIN ST. Aspen, CO 81611 Owner/Agent: Brad Hribar Centaur Construction 1200 W Lake St Suite 200 Chicago, IL 60607 312-714-8519 bhribar@centaurco.com Designer/Contractor: Steve Coughlin modif. architecture 1229 N. North Branch Street Suite 206 Chicago, IL 60642 708-261-2611 steve.coughlin@modifarchitecture.c om Project Information Energy Code: 232 MAIN ST. 1%Skylight / Roof Area Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Additional Efficiency Package(s) Building Area Floor Area 1-Ground Floor (Retail) : Nonresidential 4445 2-Second Floor (Office) : Nonresidential 1600 Envelope Assemblies Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Roof 1 wood shigle roof (type 1): Attic Roof with Wood Joists, [Bldg. Use 2 - Second Floor] 2393 19.0 23.6 0.023 0.021 Roof 2 gable roof (type 2): Insulation Entirely Above Deck, [Bldg. Use 1 - Ground Floor] 2142 ---23.6 0.041 0.028 Skylight 1: Metal Frame with Thermal Break:Glass, No Curb, Perf. Type: Energy code default, Double Pane, Clear , SHGC 0.70, VT 0.60, [Bldg. Use 1 - Ground Floor] 62 ------1.100 0.500 Roof 2 second level plaza deck floor (type 3): Insulation Entirely Above Deck, [Bldg. Use 1 - Ground Floor] 1200 ---8.6 0.107 0.028 Floor 1 (type 2A): Slab-On-Grade:Unheated, [Bldg. Use 1 - Ground Floor] (d) 275 ------0.730 0.520 NORTH Exterior North Wall (type D): Concrete Block:8", Partially Grouted, Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] 603 0.0 15.0 0.055 0.071 Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - Ground Floor]21 ------0.660 0.370 Exterior NorthWall (type C6): Steel-Framed, 16" o.c., [Bldg. Use 2 - Second Floor] 167 19.0 15.0 0.041 0.064 Exterior North Wall (type D2): Concrete Block:8", Partially Grouted,477 0.0 15.0 0.055 0.071 Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 131 ofPage 01/13/2020 Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] Door 9: Insulated Metal, Non-Swinging, [Bldg. Use 1 - Ground Floor]90 ------0.140 0.179 EAST Exterior East Wall (type C8): Steel-Framed, 16" o.c., [Bldg. Use 1 - Ground Floor] 807 25.0 20.0 0.032 0.064 Window 4 around door C-1: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 41 ------0.290 0.290 Window 5: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 97 ------0.290 0.290 Window 6: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 97 ------0.290 0.290 Window 7: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 108 ------0.290 0.290 Window 10: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.27, PF 0.33, VT 0.56, [Bldg. Use 1 - Ground Floor] (c) 22 ------0.340 0.290 Door 4 (type C-1): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID PORTELLA, SHGC 0.22, PF 0.14, VT 0.45, [Bldg. Use 1 - Ground Floor] (c) 66 ------0.350 0.770 Exterior East Wall (type B1): Steel-Framed, 16" o.c., [Bldg. Use 1 - Ground Floor] 476 0.0 15.0 0.056 0.064 Window 10: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 54 ------0.290 0.290 Window 9 around door: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 45 ------0.290 0.290 Door 3 (type C): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID PORTELLA, SHGC 0.22, PF 0.14, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 63 ------0.350 0.770 Exterior East Wall (type D): Concrete Block:8", Partially Grouted, Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] 35 0.0 15.0 0.055 0.071 SOUTH Exterior South Wall (Curtain Wall): Steel-Framed, 16" o.c., [Bldg. Use 1 - Ground Floor] 1224 19.0 0.0 0.109 0.064 Window 1: Other Window:Fixed, Perf. Specs.: Product ID KAWNEER, SHGC 0.27, PF 0.33, VT 0.56, [Bldg. Use 1 - Ground Floor] (c) 506 ------0.340 0.290 Door 2: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID PORTELLA, SHGC 0.22, PF 0.33, VT 0.34, [Bldg. Use 1 - Ground Floor] (c) 60 ------0.350 0.770 Door 2 -1: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID Nanawall HSW60, SHGC 0.27, PF 0.33, VT 0.33, [Bldg. Use 1 - Ground Floor] (c) 84 ------0.340 0.770 Door 2 -2: Glass (> 50% glazing):Metal Frame, Non-Entrance Door, Perf. Specs.: Product ID Nanawall HSW60, SHGC 0.27, PF 0.33, VT 0.33, [Bldg. Use 1 - Ground Floor] (c) 290 ------0.340 0.770 WEST Exterior West Wall (type A4): Concrete Block:8", Partially Grouted, Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] 1225 0.0 15.0 0.055 0.071 Exterior West Wall (type C6): Steel-Framed, 16" o.c., [Bldg. Use 2 - Second Floor] 476 19.0 15.0 0.041 0.064 Window 13: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID KAWNEEER, SHGC 0.27, VT 0.56, [Bldg. Use 2 - Second 6 ------0.340 0.290 Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 132 ofPage Assembly Cavity R-Value Cont. R-Value Proposed U-Factor Budget U- Factor(a) Gross Area or Perimeter Floor] (c) Window 12 around door D: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID PORTELLA, SHGC 0.25, VT 0.34, [Bldg. Use 2 - Second Floor] (c) 48 ------0.290 0.290 Door 5 (type D): Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID PORTELLA, SHGC 0.22, VT 0.45, [Bldg. Use 2 - Second Floor] (c) 42 ------0.350 0.770 Exterior West Wall (type D): Concrete Block:8", Partially Grouted, Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor] 74 0.0 15.0 0.055 0.071 (a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b)'Other' components require supporting documentation for proposed U-factors. (c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (d)Slab-On-Grade proposed and budget U-factors shown in table are F-factors. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Envelope PASSES: Design 4% better than code Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 133 ofPage STEVE COUGHLIN - PRINCIPAL 1-13-2020 Inspection Checklist Requirements: 0.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.1.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR1]1 Plans and/or specifications provide all information with which compliance can be determined for the building envelope and document where exceptions to the standard are claimed. Complies Does Not Not Observable Not Applicable C402.4.2. 2 [PR15]1 Skylights in office, storage, automotive service, manufacturing, non-refrigerated warehouse, retail store, and distribution/sorting area have a measured haze value > 90 percent unless designed to exclude direct sunlight. Complies Does Not Not Observable Not Applicable C406 [PR9]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the additional energy efficiency package options. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 136 ofPage Section # & Req.ID Footing / Foundation Inspection Complies?Comments/Assumptions C303.2 [FO4]2 Slab edge insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C303.2.1 [FO6]1 Exterior insulation protected against damage, sunlight, moisture, wind, landscaping and equipment maintenance activities. Complies Does Not Not Observable Not Applicable C402.2.5 [FO3]2 Slab edge insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [FO12]3 Radiant heating systems panels insulated to >=R-3.5 on face opposite space being heated. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 137 ofPage Section # & Req.ID Framing / Rough-In Inspection Complies?Comments/Assumptions C303.1.3 [FR12]2 Fenestration products rated in accordance with NFRC. Complies Does Not Not Observable Not Applicable C303.1.3 [FR13]1 Fenestration products are certified as to performance labels or certificates provided. Complies Does Not Not Observable Not Applicable C402.4.3 [FR10]1 Vertical fenestration SHGC value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.3 [FR11]1 Skylight SHGC value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.3, C402.4.3. 4 [FR8]1 Vertical fenestration U-Factor.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.3. 4 [FR9]1 Skylight fenestration U-Factor.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.4.4 [FR14]2 U-factor of opaque doors associated with the building thermal envelope meets requirements. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 2.1 [FR19]1 The building envelope contains a continuous air barrier that is sealed in an approved manner and material permeability <= 0.004 dfm/ft2. Air barrier penetrations are sealed in an approved manner. Complies Does Not Not Observable Not Applicable C402.5.2, C402.5.4 [FR18]3 Factory-built fenestration and doors are labeled as meeting air leakage requirements. Complies Does Not Not Observable Not Applicable C402.5.7 [FR17]3 Vestibules are installed on all building entrances. Doors have self-closing devices. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 138 ofPage Section # & Req.ID Mechanical Rough-In Inspection Complies?Comments/Assumptions C402.5.5, C403.2.4. 3 [ME3]3 Stair and elevator shaft vents have motorized dampers that automatically close. Complies Does Not Not Observable Not Applicable C402.5.5, C403.2.4. 3 [ME58]3 Outdoor air and exhaust systems have motorized dampers that automatically shut when not in use and meet maximum leakage rates. Check gravity dampers where allowed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 139 ofPage Section # & Req.ID Insulation Inspection Complies?Comments/Assumptions C303.1 [IN3]1 Roof insulation installed per manufacturer’s instructions. Blown or poured loose-fill insulation is installed only where the roof slope is <=3 in 12. Complies Does Not Not Observable Not Applicable C303.1 [IN10]2 Building envelope insulation is labeled with R-value or insulation certificate providing R-value and other relevant data. Complies Does Not Not Observable Not Applicable C303.2 [IN7]1 Above-grade wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable C303.2.1 [IN14]2 Exterior insulation is protected from damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. Complies Does Not Not Observable Not Applicable C402.1.3 [IN19]3 Non-swinging opaque doors have R- 4.75 insulation. Complies Does Not Not Observable Not Applicable C402.2.1 [IN4]3 Skylight curbs are insulated to the level of roofs with insulation above deck or R-5. Complies Does Not Not Observable Not Applicable C402.2.1 [IN17]3 Insulation intended to meet the roof insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. Complies Does Not Not Observable Not Applicable C402.2.3 [IN6]1 Above-grade wall insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.5 [IN8]2 Floor insulation R-value.Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.2.6 [IN18]3 Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Complies Does Not Not Observable Not Applicable C402.2.2 [IN2]1 Roof R-value. For some ceiling systems, verification may need to occur during Framing Inspection. Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. C402.5.1. 1 [IN1]1 All sources of air leakage in the building thermal envelope are sealed, caulked, gasketed, weather stripped or wrapped with moisture vapor- permeable wrapping material to minimize air leakage. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 1310 ofPage 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 1311 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions C402.5.3 [FI51]3 Where open combustion air ducts provide combustion air to open combustion fuel burning appliances, the appliances and combustion air opening are located outside the building thermal envelope or enclosed in a room, isolated from inside the thermal envelope. Such rooms are sealed and insulated. Complies Does Not Not Observable Not Applicable C402.5.6 [FI37]1 Weatherseals installed on all loading dock cargo doors. Complies Does Not Not Observable Not Applicable C402.5.8 [FI26]3 Recessed luminaires in thermal envelope to limit infiltration and be IC rated and labeled. Seal between interior finish and luminaire housing. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 1312 ofPage Project Title: Data filename: 232 MAIN ST. C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN ST 3-12-19_permit comments.cck 01/13/20Report date: 1313 ofPage