HomeMy WebLinkAboutFile Documents.232 E Main St.0132.2018 (105).ACBKCOMcheck Software Version 4.1.1.0
Envelope Compliance Certificate
Project Title:
2015 IECC
Project Type:New Construction
Permit Date:1/2018
Vertical Glazing / Wall Area:29%
Location:Aspen, Colorado
Climate Zone:7
Construction Site:
232 E. MAIN ST.
Aspen, CO 81611
Owner/Agent:
Brad Hribar
Centaur Construction
1200 W Lake St Suite 200
Chicago, IL 60607
312-714-8519
bhribar@centaurco.com
Designer/Contractor:
Steve Coughlin
modif. architecture
1229 N. North Branch Street Suite
206
Chicago, IL 60642
708-261-2611
steve.coughlin@modifarchitecture.c
om
Project Information
Energy Code:
232 MAIN ST.
1%Skylight / Roof Area
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations.
Additional Efficiency Package(s)
Building Area Floor Area
1-Ground Floor (Retail) : Nonresidential 4445
2-Second Floor (Office) : Nonresidential 1600
Envelope Assemblies
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Roof 1 wood shigle roof (type 1): Attic Roof with Wood Joists, [Bldg.
Use 2 - Second Floor]
2393 19.0 23.6 0.023 0.021
Roof 2 gable roof (type 2): Insulation Entirely Above Deck, [Bldg. Use 1
- Ground Floor]
2142 ---23.6 0.041 0.028
Skylight 1: Metal Frame with Thermal Break:Glass, No Curb, Perf.
Type: Energy code default, Double Pane, Clear , SHGC 0.70, VT 0.60,
[Bldg. Use 1 - Ground Floor]
62 ------1.100 0.500
Roof 2 second level plaza deck floor (type 3): Insulation Entirely Above
Deck, [Bldg. Use 1 - Ground Floor]
1200 ---8.6 0.107 0.028
Floor 1 (type 2A): Slab-On-Grade:Unheated, [Bldg. Use 1 - Ground
Floor] (d)
275 ------0.730 0.520
NORTH
Exterior North Wall (type D): Concrete Block:8", Partially Grouted, Cells
Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor]
603 0.0 15.0 0.055 0.071
Door 1: Insulated Metal, Swinging, [Bldg. Use 1 - Ground Floor]21 ------0.660 0.370
Exterior NorthWall (type C6): Steel-Framed, 16" o.c., [Bldg. Use 2 -
Second Floor]
167 19.0 15.0 0.041 0.064
Exterior North Wall (type D2): Concrete Block:8", Partially Grouted,477 0.0 15.0 0.055 0.071
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 3-12-19_permit comments.cck
01/13/20Report date:
131 ofPage
01/13/2020
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Cells Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground
Floor]
Door 9: Insulated Metal, Non-Swinging, [Bldg. Use 1 - Ground Floor]90 ------0.140 0.179
EAST
Exterior East Wall (type C8): Steel-Framed, 16" o.c., [Bldg. Use 1 -
Ground Floor]
807 25.0 20.0 0.032 0.064
Window 4 around door C-1: Metal Frame with Thermal Break:Fixed,
Perf. Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34,
[Bldg. Use 1 - Ground Floor] (c)
41 ------0.290 0.290
Window 5: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 -
Ground Floor] (c)
97 ------0.290 0.290
Window 6: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 -
Ground Floor] (c)
97 ------0.290 0.290
Window 7: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 -
Ground Floor] (c)
108 ------0.290 0.290
Window 10: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID KAWNEER, SHGC 0.27, PF 0.33, VT 0.56, [Bldg. Use 1 -
Ground Floor] (c)
22 ------0.340 0.290
Door 4 (type C-1): Glass (> 50% glazing):Metal Frame, Entrance Door,
Perf. Specs.: Product ID PORTELLA, SHGC 0.22, PF 0.14, VT 0.45,
[Bldg. Use 1 - Ground Floor] (c)
66 ------0.350 0.770
Exterior East Wall (type B1): Steel-Framed, 16" o.c., [Bldg. Use 1 -
Ground Floor]
476 0.0 15.0 0.056 0.064
Window 10: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg. Use 1 -
Ground Floor] (c)
54 ------0.290 0.290
Window 9 around door: Metal Frame with Thermal Break:Fixed, Perf.
Specs.: Product ID PORTELLA, SHGC 0.25, PF 0.14, VT 0.34, [Bldg.
Use 1 - Ground Floor] (c)
45 ------0.290 0.290
Door 3 (type C): Glass (> 50% glazing):Metal Frame, Entrance Door,
Perf. Specs.: Product ID PORTELLA, SHGC 0.22, PF 0.14, VT 0.34,
[Bldg. Use 1 - Ground Floor] (c)
63 ------0.350 0.770
Exterior East Wall (type D): Concrete Block:8", Partially Grouted, Cells
Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor]
35 0.0 15.0 0.055 0.071
SOUTH
Exterior South Wall (Curtain Wall): Steel-Framed, 16" o.c., [Bldg. Use 1
- Ground Floor]
1224 19.0 0.0 0.109 0.064
Window 1: Other Window:Fixed, Perf. Specs.: Product ID KAWNEER,
SHGC 0.27, PF 0.33, VT 0.56, [Bldg. Use 1 - Ground Floor] (c)
506 ------0.340 0.290
Door 2: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf.
Specs.: Product ID PORTELLA, SHGC 0.22, PF 0.33, VT 0.34, [Bldg.
Use 1 - Ground Floor] (c)
60 ------0.350 0.770
Door 2 -1: Glass (> 50% glazing):Metal Frame, Non-Entrance Door,
Perf. Specs.: Product ID Nanawall HSW60, SHGC 0.27, PF 0.33, VT
0.33, [Bldg. Use 1 - Ground Floor] (c)
84 ------0.340 0.770
Door 2 -2: Glass (> 50% glazing):Metal Frame, Non-Entrance Door,
Perf. Specs.: Product ID Nanawall HSW60, SHGC 0.27, PF 0.33, VT
0.33, [Bldg. Use 1 - Ground Floor] (c)
290 ------0.340 0.770
WEST
Exterior West Wall (type A4): Concrete Block:8", Partially Grouted, Cells
Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor]
1225 0.0 15.0 0.055 0.071
Exterior West Wall (type C6): Steel-Framed, 16" o.c., [Bldg. Use 2 -
Second Floor]
476 19.0 15.0 0.041 0.064
Window 13: Metal Frame with Thermal Break:Fixed, Perf. Specs.:
Product ID KAWNEEER, SHGC 0.27, VT 0.56, [Bldg. Use 2 - Second
6 ------0.340 0.290
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 3-12-19_permit comments.cck
01/13/20Report date:
132 ofPage
Assembly Cavity
R-Value
Cont.
R-Value
Proposed
U-Factor
Budget U-
Factor(a)
Gross Area
or
Perimeter
Floor] (c)
Window 12 around door D: Metal Frame with Thermal Break:Fixed,
Perf. Specs.: Product ID PORTELLA, SHGC 0.25, VT 0.34, [Bldg. Use
2 - Second Floor] (c)
48 ------0.290 0.290
Door 5 (type D): Glass (> 50% glazing):Metal Frame, Entrance Door,
Perf. Specs.: Product ID PORTELLA, SHGC 0.22, VT 0.45, [Bldg. Use
2 - Second Floor] (c)
42 ------0.350 0.770
Exterior West Wall (type D): Concrete Block:8", Partially Grouted, Cells
Empty, Normal Density, Furring: Metal, [Bldg. Use 1 - Ground Floor]
74 0.0 15.0 0.055 0.071
(a)Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b)'Other' components require supporting documentation for proposed U-factors.
(c)Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(d)Slab-On-Grade proposed and budget U-factors shown in table are F-factors.
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory
requirements listed in the Inspection Checklist.
Name - Title Signature Date
Envelope PASSES: Design 4% better than code
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 3-12-19_permit comments.cck
01/13/20Report date:
133 ofPage
STEVE COUGHLIN - PRINCIPAL 1-13-2020
Inspection Checklist
Requirements: 0.0% were addressed directly in the COMcheck software
COMcheck Software Version 4.1.1.0
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2015 IECC
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
C103.2
[PR1]1
Plans and/or specifications provide all
information with which compliance
can be determined for the building
envelope and document where
exceptions to the standard are
claimed.
Complies
Does Not
Not Observable
Not Applicable
C402.4.2.
2
[PR15]1
Skylights in office, storage,
automotive service, manufacturing,
non-refrigerated warehouse, retail
store, and distribution/sorting area
have a measured haze value > 90
percent unless designed to exclude
direct sunlight.
Complies
Does Not
Not Observable
Not Applicable
C406
[PR9]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the additional energy
efficiency package options.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 3-12-19_permit comments.cck
01/13/20Report date:
136 ofPage
Section
#
& Req.ID
Footing / Foundation Inspection Complies?Comments/Assumptions
C303.2
[FO4]2
Slab edge insulation installed per
manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
C303.2.1
[FO6]1
Exterior insulation protected against
damage, sunlight, moisture, wind,
landscaping and equipment
maintenance activities.
Complies
Does Not
Not Observable
Not Applicable
C402.2.5
[FO3]2
Slab edge insulation R-value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.6
[FO12]3
Radiant heating systems panels
insulated to >=R-3.5 on face opposite
space being heated.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 3-12-19_permit comments.cck
01/13/20Report date:
137 ofPage
Section
#
& Req.ID
Framing / Rough-In Inspection Complies?Comments/Assumptions
C303.1.3
[FR12]2
Fenestration products rated in
accordance with NFRC.
Complies
Does Not
Not Observable
Not Applicable
C303.1.3
[FR13]1
Fenestration products are certified as
to performance labels or certificates
provided.
Complies
Does Not
Not Observable
Not Applicable
C402.4.3
[FR10]1
Vertical fenestration SHGC value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.3
[FR11]1
Skylight SHGC value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.3,
C402.4.3.
4
[FR8]1
Vertical fenestration U-Factor.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.3.
4
[FR9]1
Skylight fenestration U-Factor.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.4.4
[FR14]2
U-factor of opaque doors associated
with the building thermal envelope
meets requirements.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.5.1.
2.1
[FR19]1
The building envelope contains a
continuous air barrier that is sealed in
an approved manner and material
permeability <= 0.004 dfm/ft2. Air
barrier penetrations are sealed in an
approved manner.
Complies
Does Not
Not Observable
Not Applicable
C402.5.2,
C402.5.4
[FR18]3
Factory-built fenestration and doors
are labeled as meeting air leakage
requirements.
Complies
Does Not
Not Observable
Not Applicable
C402.5.7
[FR17]3
Vestibules are installed on all building
entrances. Doors have self-closing
devices.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 3-12-19_permit comments.cck
01/13/20Report date:
138 ofPage
Section
#
& Req.ID
Mechanical Rough-In Inspection Complies?Comments/Assumptions
C402.5.5,
C403.2.4.
3
[ME3]3
Stair and elevator shaft vents have
motorized dampers that automatically
close.
Complies
Does Not
Not Observable
Not Applicable
C402.5.5,
C403.2.4.
3
[ME58]3
Outdoor air and exhaust systems have
motorized dampers that automatically
shut when not in use and meet
maximum leakage rates. Check
gravity dampers where allowed.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 3-12-19_permit comments.cck
01/13/20Report date:
139 ofPage
Section
#
& Req.ID
Insulation Inspection Complies?Comments/Assumptions
C303.1
[IN3]1
Roof insulation installed per
manufacturer’s instructions. Blown or
poured loose-fill insulation is installed
only where the roof slope is <=3 in
12.
Complies
Does Not
Not Observable
Not Applicable
C303.1
[IN10]2
Building envelope insulation is labeled
with R-value or insulation certificate
providing R-value and other relevant
data.
Complies
Does Not
Not Observable
Not Applicable
C303.2
[IN7]1
Above-grade wall insulation installed
per manufacturer’s instructions.
Complies
Does Not
Not Observable
Not Applicable
C303.2.1
[IN14]2
Exterior insulation is protected from
damage with a protective material.
Verification for exposed foundation
insulation may need to occur during
Foundation Inspection.
Complies
Does Not
Not Observable
Not Applicable
C402.1.3
[IN19]3
Non-swinging opaque doors have R-
4.75 insulation.
Complies
Does Not
Not Observable
Not Applicable
C402.2.1
[IN4]3
Skylight curbs are insulated to the
level of roofs with insulation above
deck or R-5.
Complies
Does Not
Not Observable
Not Applicable
C402.2.1
[IN17]3
Insulation intended to meet the roof
insulation requirements cannot be
installed on top of a suspended
ceiling. Mark this requirement
compliant if insulation is installed
accordingly.
Complies
Does Not
Not Observable
Not Applicable
C402.2.3
[IN6]1
Above-grade wall insulation R-value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.5
[IN8]2
Floor insulation R-value.Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.2.6
[IN18]3
Radiant panels and associated
components, designed for heat
transfer from the panel surfaces to the
occupants or indoor space are
insulated with a minimum of R-3.5.
Complies
Does Not
Not Observable
Not Applicable
C402.2.2
[IN2]1
Roof R-value. For some ceiling
systems, verification may need to
occur during Framing Inspection.
Complies
Does Not
Not Observable
Not Applicable
See the Envelope Assemblies table for values.
C402.5.1.
1
[IN1]1
All sources of air leakage in the
building thermal envelope are sealed,
caulked, gasketed, weather stripped
or wrapped with moisture vapor-
permeable wrapping material to
minimize air leakage.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 3-12-19_permit comments.cck
01/13/20Report date:
1310 ofPage
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 3-12-19_permit comments.cck
01/13/20Report date:
1311 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
C402.5.3
[FI51]3
Where open combustion air ducts
provide combustion air to open
combustion fuel burning appliances,
the appliances and combustion air
opening are located outside the
building thermal envelope or enclosed
in a room, isolated from inside the
thermal envelope. Such rooms are
sealed and insulated.
Complies
Does Not
Not Observable
Not Applicable
C402.5.6
[FI37]1
Weatherseals installed on all loading
dock cargo doors.
Complies
Does Not
Not Observable
Not Applicable
C402.5.8
[FI26]3
Recessed luminaires in thermal
envelope to limit infiltration and be IC
rated and labeled. Seal between
interior finish and luminaire housing.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 3-12-19_permit comments.cck
01/13/20Report date:
1312 ofPage
Project Title:
Data filename:
232 MAIN ST.
C:\Users\mwarnes\Modif Dropbox\Aspen\2016-005 232 E Main St\municipal\ComCheck\232 MAIN
ST 3-12-19_permit comments.cck
01/13/20Report date:
1313 ofPage