HomeMy WebLinkAboutFile Documents.754 Moore Dr.0034.2018 (48).ARBKREScheck Software Version 4.6.4 Compliance Certificate Project LOT 12 Energy Code:2015 IECC Location:Aspen, Colorado Construction Type:Single-family Project Type:New Construction Orientation:Bldg. faces 315 deg. from North Conditioned Floor Area:11,236 ft2 Glazing Area 21% Climate Zone:7 (9922 HDD) Permit Date: Construction Site: 754 Moore Drive Aspen, CO 81611 Owner/Agent: Five Trees LLC 222 North Lasalle St. Suite 800 Chicago, IL 60601 Designer/Contractor: Rowland+Broughton 234 East Hopkins St. Aspen, CO 81611 970.544.9006 Permit Number: Compliance: Passes using UA trade-off 2.7% Better Than Code Maximum UA:1482 Your UA:1442 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Ceiling (R-3/R-4) - Over Gym: Flat Ceiling or Scissor Truss 669 39.0 13.0 0.021 14 Ceiling (R-3) - Over MEP/Pool Crawl Space: Flat Ceiling or Scissor Truss 493 39.0 13.0 0.021 10 Ceiling (R-1a/R-1b) - Green Roof: Flat Ceiling or Scissor Truss 1,482 39.0 15.0 0.020 30 Skylight Over Kitchen: Metal Frame:Double Pane with Low-E 216 0.550 119 Ceiling (F-8) - Upper Deck (Bed 2): Flat Ceiling or Scissor Truss 118 39.0 11.0 0.022 3 Ceiling (F-8 SIM.) - Over Garage: Flat Ceiling or Scissor Truss 29 39.0 10.0 0.023 1 Floor (F-5) - Upper Level Overhang: All-Wood Joist/Truss:Over Outside Air 32 56.0 0.0 0.019 1 Ceiling (R-5 SIM.) - Roof w/ Flat Ceiling: Flat Ceiling or Scissor Truss 1,994 40.0 10.0 0.022 44 Ceiling (R-5) - Roof w/ Vaulted Ceiling: Cathedral Ceiling 988 40.0 10.0 0.020 20 Floor (F-1/F4b) - Main Level SOG: Slab-On-Grade:Heated Insulation depth: 2.0' 150 10.0 0.767 115 Wall (W-7/W-8) - East Facade: Wood Frame, 16" o.c. Orientation: Right side 1,523 16.0 10.0 0.039 42 Window - East Facade: Wood Frame:Double Pane with Low-E Orientation: Right side 233 0.359 84 Door (Lift-Slide) - East Facade: Glass Orientation: Right side 207 0.350 72 Wall (W-5) - East (Egress Well): Solid Concrete or Masonry:Exterior Insulation Orientation: Right side 58 19.0 10.0 0.037 2 Project Title: LOT 12 Data filename: C:\Users\jborkovec\Documents\REScheck\LOT 12\LOT 12 - UA Compliance_v4.2.6 - 2.1(Continuous, 0.3589, 0.55, high cavity, no Bsmnt flr.).rck Page 1 of 11 12/14/18Report date: 1/2/2019 01/22/2019 nickt Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Window - Egress Well - East Facade: Wood Frame:Double Pane with Low-E Orientation: Unspecified 9 0.359 3 Wall (W-8) - East (Courtyard): Wood Frame, 16" o.c. Orientation: Right side 165 16.0 10.0 0.039 6 Wall (W-7/W-8) - North Facade: Wood Frame, 16" o.c. Orientation: Front 1,895 16.0 10.0 0.039 45 Windows - North Facade: Wood Frame:Double Pane with Low-E Orientation: Front 275 0.359 99 Doors (Deck 2): Glass Orientation: Front 23 0.359 8 Door (Lift-Slide) - North Facade: Glass Orientation: Unspecified 262 0.350 92 Garage Door: Solid Orientation: Front 176 0.143 25 Wall (W-7) - North (Courtyard): Wood Frame, 16" o.c. Orientation: Front 380 16.0 10.0 0.039 7 Windows - North (Courtyard): Wood Frame:Double Pane with Low-E Orientation: Front 177 0.359 64 Door (Mud Entry): Glass Orientation: Front 23 0.359 8 Wall (W-9) - South (Area-Way w/ Out Rigid): Wood Frame, 16" o.c. Orientation: Back 703 26.0 0.0 0.052 37 Wall (W-13) - South (CMU @ Kitchen): Solid Concrete or Masonry:Interior Insulation Orientation: Back 292 26.0 0.0 0.056 16 Wall (W-7/W-8) - South (w/ Rigid): Wood Frame, 16" o.c. Orientation: Back 1,269 16.0 10.0 0.039 44 Windows - South Facade: Wood Frame:Double Pane with Low-E Orientation: Back 116 0.359 42 Door (Vestibule): Glass Orientation: Back 26 0.359 9 Wall (W-5) - South (Egress Well): Solid Concrete or Masonry:Exterior Insulation Orientation: Back 71 19.0 10.0 0.037 2 Window - Egress Well - South Facade: Wood Frame:Double Pane with Low-E Orientation: Unspecified 9 0.359 3 Wall (W-9) - East (Area-Way w/ out Rigid): Wood Frame, 16" o.c. Orientation: Right side 33 26.0 0.0 0.052 2 Wall (W-8) - East (Area-Way w/ Rigid): Wood Frame, 16" o.c. Orientation: Right side 35 16.0 10.0 0.039 1 Wall (W-13) - West (CMU @ Kitchen): Solid Concrete or Masonry:Interior Insulation Orientation: Left side 46 26.0 0.0 0.056 3 Wall (W-9) - West (Area-Way w/ out Rigid): Wood Frame, 16" o.c. Orientation: Left side 33 26.0 0.0 0.052 2 Wall (W-8) - West (Area-Way w/ Rigid): Wood Frame, 16" o.c. Orientation: Left side 33 16.0 10.0 0.039 1 Wall (W-7/W-8/W-9b) - West Facade: Wood Frame, 16" o.c. Orientation: Left side 559 16.0 10.0 0.039 19 Windows - West Facade: Wood Frame:Double Pane with Low-E Orientation: Left side 28 0.359 10 Door (Trash/Garage): Solid Orientation: Left side 44 0.143 6 Wall (W-7/W-8) - West (Courtyard): Wood Frame, 16" o.c. Orientation: Left side 1,062 16.0 10.0 0.039 27 Windows - West Courtyard: Wood Frame:Double Pane with Low-E Orientation: Left side 338 0.359 121 Door - Main Entry: Solid Orientation: Left side 38 0.143 5 Project Title: LOT 12 Data filename: C:\Users\jborkovec\Documents\REScheck\LOT 12\LOT 12 - UA Compliance_v4.2.6 - 2.1(Continuous, 0.3589, 0.55, high cavity, no Bsmnt flr.).rck Page 2 of 11 12/14/18Report date: 1/2/2019 Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Basement Wall (W-2) - East (Dwelling): Solid Concrete or Masonry Orientation: Right side Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' 206 19.0 10.0 0.027 6 Basement Wall (W-1) - East (Crawl Space): Solid Concrete or Masonry Orientation: Right side Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' 438 0.0 10.0 0.048 21 Basement Wall (W-2) - North (Gym): Solid Concrete or Masonry Orientation: Front Wall height: 12.0' Depth below grade: 7.5' Insulation depth: 12.0' 221 19.0 10.0 0.032 7 Basement Wall (W-1) - North (Crawl Space): Solid Concrete or Masonry Orientation: Front Wall height: 12.0' Depth below grade: 6.0' Insulation depth: 12.0' 1,087 0.0 10.0 0.073 79 Basement Wall (W-2) - South: Solid Concrete or Masonry Orientation: Back Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' 1,228 19.0 10.0 0.027 33 Basement Wall (W-2) - West (w/ Rigid & Batt): Solid Concrete or Masonry Orientation: Left side Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' 442 19.0 10.0 0.027 12 Basement Wall (W-1) - West (Crawl Space, Below Grade): Solid Concrete or Masonry Orientation: Left side Wall height: 12.0' Depth below grade: 12.0' Insulation depth: 12.0' 82 0.0 10.0 0.048 4 Basement Wall (W-1) - West (Crawl Space, Exposed): Solid Concrete or Masonry Orientation: Left side Wall height: 12.0' Depth below grade: 7.0' Insulation depth: 12.0' 227 0.0 10.0 0.069 16 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: LOT 12 Data filename: C:\Users\jborkovec\Documents\REScheck\LOT 12\LOT 12 - UA Compliance_v4.2.6 - 2.1(Continuous, 0.3589, 0.55, high cavity, no Bsmnt flr.).rck Page 3 of 11 12/14/18Report date: 1/2/2019 Inspection Checklist Requirements: 0.0% were addressed directly in the REScheck software REScheck Software Version 4.6.4 Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies?Comments/Assumptions 103.1, 103.2 [PR1]1 Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. Complies Does Not Not Observable Not Applicable 103.1, 103.2, 403.7 [PR3]1 Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. Complies Does Not Not Observable Not Applicable 302.1, 403.7 [PR2]2 Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_____ Cooling: Btu/hr_____ Heating: Btu/hr_____ Cooling: Btu/hr_____ Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: LOT 12 Data filename: C:\Users\jborkovec\Documents\REScheck\LOT 12\LOT 12 - UA Compliance_v4.2.6 - 2.1(Continuous, 0.3589, 0.55, high cavity, no Bsmnt flr.).rck Page 4 of 11 12/14/18Report date: 1/2/2019 Section # & Req.ID Foundation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.2 [FO1]1 Slab edge insulation R-value.R-_____ Unheated Heated R-_____ Unheated Heated Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.2 [FO3]1 Slab edge insulation depth/length. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1 [FO4]1 Conditioned basement wall insulation R-value. Where interior insulation is used, verification may need to occur during Insulation Inspection. Not required in warm-humid locations in Climate Zone 3. R-_____ R-_____ R-_____ R-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [FO5]1 Conditioned basement wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable 402.2.9 [FO6]1 Conditioned basement wall insulation depth of burial or distance from top of wall. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2.1 [FO11]2 A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. Complies Does Not Not Observable Not Applicable 403.9 [FO12]2 Snow- and ice-melting system controls installed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: LOT 12 Data filename: C:\Users\jborkovec\Documents\REScheck\LOT 12\LOT 12 - UA Compliance_v4.2.6 - 2.1(Continuous, 0.3589, 0.55, high cavity, no Bsmnt flr.).rck Page 5 of 11 12/14/18Report date: 1/2/2019 Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.3.4 [FR1]1 Door U-factor.U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1, 402.3.1, 402.3.3, 402.3.6, 402.5 [FR2]1 Glazing U-factor (area-weighted average). U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.3 [FR4]1 U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. Complies Does Not Not Observable Not Applicable 402.1.1, 402.3.3, 402.3.6, 402.5 [FR5]1 Skylight U-factor.U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1 [FR10]1 Mass wall exterior insulation R- value. If more than ½ of the insulation is on the wall interior, the interior insulation requirement applies and verification may need to occur during Insulation Inspection. R-_____R-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [FR11]1 Mass wall exterior insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable 402.4.1.1 [FR23]1 Air barrier and thermal barrier installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable 402.4.3 [FR20]1 Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. Complies Does Not Not Observable Not Applicable 402.4.5 [FR16]2 IC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate ≤2.0 cfm leakage at 75 Pa. Complies Does Not Not Observable Not Applicable 403.2.1 [FR12]1 Supply and return ducts in attics insulated >= R-8 where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. Complies Does Not Not Observable Not Applicable 403.3.3.5 [FR15]3 Building cavities are not used as ducts or plenums. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: LOT 12 Data filename: C:\Users\jborkovec\Documents\REScheck\LOT 12\LOT 12 - UA Compliance_v4.2.6 - 2.1(Continuous, 0.3589, 0.55, high cavity, no Bsmnt flr.).rck Page 6 of 11 12/14/18Report date: 1/2/2019 Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.4 [FR17]2 HVAC piping conveying fluids above 105 ºF or chilled fluids below 55 ºF are insulated to ≥R- 3. R-_____R-_____Complies Does Not Not Observable Not Applicable 403.4.1 [FR24]1 Protection of insulation on HVAC piping. Complies Does Not Not Observable Not Applicable 403.5.3 [FR18]2 Hot water pipes are insulated to ≥R-3. R-_____R-_____Complies Does Not Not Observable Not Applicable 403.6 [FR19]2 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: LOT 12 Data filename: C:\Users\jborkovec\Documents\REScheck\LOT 12\LOT 12 - UA Compliance_v4.2.6 - 2.1(Continuous, 0.3589, 0.55, high cavity, no Bsmnt flr.).rck Page 7 of 11 12/14/18Report date: 1/2/2019 Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 303.1 [IN13]2 All installed insulation is labeled or the installed R-values provided. Complies Does Not Not Observable Not Applicable 402.1.1, 402.2.6 [IN1]1 Floor insulation R-value.R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2, 402.2.7 [IN2]1 Floor insulation installed per manufacturer’s instructions and in substantial contact with the underside of the subfloor, or floor framing cavity insulation is in contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Complies Does Not Not Observable Not Applicable 402.1.1, 402.2.5, 402.2.6 [IN3]1 Wall insulation R-value. If this is a mass wall with at least ½ of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-_____ Wood Mass Steel R-_____ Wood Mass Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [IN4]1 Wall insulation is installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: LOT 12 Data filename: C:\Users\jborkovec\Documents\REScheck\LOT 12\LOT 12 - UA Compliance_v4.2.6 - 2.1(Continuous, 0.3589, 0.55, high cavity, no Bsmnt flr.).rck Page 8 of 11 12/14/18Report date: 1/2/2019 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.2.1, 402.2.2, 402.2.6 [FI1]1 Ceiling insulation R-value.R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.1.1, 303.2 [FI2]1 Ceiling insulation installed per manufacturer’s instructions. Blown insulation marked every 300 ft². Complies Does Not Not Observable Not Applicable 402.2.3 [FI22]2 Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. Complies Does Not Not Observable Not Applicable 402.2.4 [FI3]1 Attic access hatch and door insulation ≥R-value of the adjacent assembly. R-_____R-_____Complies Does Not Not Observable Not Applicable 402.4.1.2 [FI17]1 Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. ACH 50 =_____ACH 50 =_____Complies Does Not Not Observable Not Applicable 403.2.3 [FI4]1 Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing Inspection. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.2 [FI27]1 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer’s air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer’s air handler enclosure. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable 403.3.2.1 [FI24]1 Air handler leakage designated by manufacturer at <=2% of design air flow. Complies Does Not Not Observable Not Applicable 403.1.1 [FI9]2 Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. Complies Does Not Not Observable Not Applicable 403.1.2 [FI10]2 Heat pump thermostat installed on heat pumps. Complies Does Not Not Observable Not Applicable 403.5.1 [FI11]2 Circulating service hot water systems have automatic or accessible manual controls. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: LOT 12 Data filename: C:\Users\jborkovec\Documents\REScheck\LOT 12\LOT 12 - UA Compliance_v4.2.6 - 2.1(Continuous, 0.3589, 0.55, high cavity, no Bsmnt flr.).rck Page 9 of 11 12/14/18Report date: 1/2/2019 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.6.1 [FI25]2 All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits. Complies Does Not Not Observable Not Applicable 403.2 [FI26]2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. Complies Does Not Not Observable Not Applicable 403.5.1.1 [FI28]2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. Complies Does Not Not Observable Not Applicable 403.5.1.2 [FI29]2 Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. Complies Does Not Not Observable Not Applicable 403.5.2 [FI30]2 Water distribution systems that have recirculation pumps that pump water from a heated water supply pipe back to the heated water source through a cold water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104ºF. Complies Does Not Not Observable Not Applicable 403.5.4 [FI31]2 Drain water heat recovery units tested in accordance with CSA B55.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. Complies Does Not Not Observable Not Applicable 403.10.2 [FI12]3 Readily accessible switch on heaters for swimming pools or permanent in-ground spas. Switch operation does not change heater thermostat setting. Heater circuit breaker is installed independent of switch. Gas-fired heaters equipped with ignition pilots that are not continuously burning pilots. Complies Does Not Not Observable Not Applicable 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: LOT 12 Data filename: C:\Users\jborkovec\Documents\REScheck\LOT 12\LOT 12 - UA Compliance_v4.2.6 - 2.1(Continuous, 0.3589, 0.55, high cavity, no Bsmnt flr.).rck Page 10 of 11 12/14/18Report date: 1/2/2019 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.10.3 [FI19]3 Timer switches or other automatic preset schedule control method are installed on heaters and pumps serving pools and permanent Complies Does Not Not Observable Not Applicable 403.10.4 [FI20]3 Outdoor heated pools and outdoor permanent spas have a vapor retardant cover. Complies Does Not Not Observable Not Applicable 404.1 [FI6]1 75% of lamps in permanent fixtures or 75% of permanent fixtures have high efficacy lamps. Does not apply to low-voltage lighting. Complies Does Not Not Observable Not Applicable 404.1.1 [FI23]3 Fuel gas lighting systems have no continuous pilot light. Complies Does Not Not Observable Not Applicable 401.3 [FI7]2 Compliance certificate posted.Complies Does Not Not Observable Not Applicable 303.3 [FI18]3 Manufacturer manuals for mechanical and water heating systems have been provided. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: LOT 12 Data filename: C:\Users\jborkovec\Documents\REScheck\LOT 12\LOT 12 - UA Compliance_v4.2.6 - 2.1(Continuous, 0.3589, 0.55, high cavity, no Bsmnt flr.).rck Page 11 of 11 12/14/18Report date: 1/2/2019 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value 26.00Above-Grade Wall 29.00Below-Grade Wall 10.00Floor 50.00Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.36Window 0.35Door 0.55Skylight Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name:Date: Comments 1/2/2019