Loading...
HomeMy WebLinkAboutFile Documents.533 W Hallam St.0285.2018 (113).ARBK 300 SO SPRING ST | 202 | ASPEN, CO 81611 970.925.2855 | BENDONADAMS.COM July 12, 2018 Aspen Historic Preservation Commission c/o Ms. Sarah Yoon, Historic Preservation Planner City of Aspen 130 So. Galena St. Aspen, Colorado 81611 RE: 533 West Hallam Final Design Application Dear Commission and Ms. Yoon: Please accept this application for Final Design Review for the project at 533 West Hallam Street. HPC granted Conceptual approval, the 500 sf FAR Bonus and variations on April 11, 2018 via HPC Resolution Number 4, Series of 2018. City Council agreed with HPC’s decision and did not exercise their call-up authority. The Final Design application details the historic preservation plan to restore the home, proposed materials, windows, lighting, and other architectural details. The materials shown during Conceptual Review are unchanged in this proposal. A preliminary storm water management plan is included in the drawing set as required in the HPC conceptual approval. We look forward to presenting this final step in the review process for the Duncan’s home. Please let me know if you need any additional information to complete your review. Kind Regards, Kind Regards, Sara Adams, AICP Principal BendonAdams, LLC Attachments: A – Major Development Final Review B – HPC Resolution 4, 2018 533 West Hallam Street Final HPC Reviews C – Pre-application conference summary D – Land Use Application and Dimensional Requirements Form E – Vicinity Map F – Authorization to Represent G – Proof of ownership H – Agreement to Pay I – HOA form J – Mailing list K – Drawings (including street context, preservation plan details, stormwater plan, landscape, lighting, materials, survey, etc.) Exhibit A Final Design Review Exhibit A – Final Design Review 26.415.070. Development involving designated historic property or property within a historic district. No building, structure or landscape shall be erected, constructed, enlarged, altered, repaired, relocated or improved involving a designated historic property or a property located within a Historic District until plans or sufficient information have been submitted to the Community Development Director and approved in accordance with the procedures established for their review. An application for a building permit cannot be submitted without a development order. b) The procedures for the review of conceptual development plans for major development projects are as follows: (1) The Community Development Director shall review the application materials submitted for conceptual or final development plan approval. If they are determined to be complete, the applicant will be notified in writing of this and a public hearing before the HPC shall be scheduled. Notice of the hearing shall be provided pursuant to Section 26.304.060.E.3 Paragraphs a, b and c. (2) Staff shall review the submittal material and prepare a report that analyzes the project's conformance with the design guidelines and other applicable Land Use Code sections. This report will be transmitted to the HPC with relevant information on the proposed project and a recommendation to continue, approve, disapprove or approve with conditions and the reasons for the recommendation. The HPC will review the application, the staff analysis report and the evidence presented at the hearing to determine the project's conformance with the City Historic Preservation Design Guidelines. Response: Applicable Design Guidelines are addressed below: 1.1 Preserve original fences. • Replace only those portions that are deteriorated beyond repair. Replacement elements should match the existing fence. 1.2 A new replacement fence should use materials that appear similar to that of the original. • Any fence which is visible from a public right-of-way must be built of wood or wrought iron. Wire fences also may be considered. • A wood picket fence is an appropriate replacement in most locations. A simple wire or metal fence, similar to traditional "wrought iron," also may be considered. • Chain link is prohibited and solid "stockade" fences are only allowed in side and rear yards. 1.3 A new replacement fence should have a “transparent” quality allowing views into the yard from the street. • A fence that defines a front yard is usually low to the ground and "transparent" in nature. • On residential properties, a fence which is located forward of the front building facade may not be taller than 42" from natural grade. (For additional information, see the City of Aspen's "Residential Design Standards".) • A privacy fence may be used in back yards and along alleys, but not forward of the front facade of a building. • Note that using no fencing at all is often the best approach. Site Design Exhibit A Final Design Review • Contemporary interpretations of traditional fences should be compatible with the historic context. 1.4 New fence components should be similar in scale with those seen traditionally. • Fence columns or piers should be proportional to the fence segment. 1.5 A side yard fence which extends between two homes should be set back from the street- facing facade. • This setback should be significant enough to provide a sense of open space between homes. 1.6 Replacement or new fencing between side yards and along the alley should be compatible with the historic context. • A side yard fence is usually taller than its front yard counterpart. It also is less transparent. A side yard fence may reach heights taller than front yard fences (up to six feet), but should incorporate transparent elements to minimize the possible visual impacts. • Consider staggering the fence boards on either side of the fence rail. This will give the appearance of a solid plank fence when seen head on. • Also consider using lattice, or other transparent detailing, on the upper portions of the fence. Response: The proposed site plan includes removing the non-historic fence along Hallam Street and constructing a new fence along Fifth Street. The proposed painted wood fences are simple in design and similar to wood fences found on other historic properties in the West End. For the fence facing Fifth Street, the space between pickets is equal to the width of the picket as shown below. (Sheet HPC3.07) There is no fence facing Hallam Street. A property line fence of about 5’6” in height is proposed along the shared property line. 1.9 Maintain the established progression of public-to-private spaces when considering a rehabilitation project. Exhibit A Final Design Review • This includes a sequence of experiences, beginning with the "public" sidewalk, proceeding along a "semi-public" walkway, to a "semi-private" porch or entry feature and ending in the "private" spaces beyond. • Provide a walkway running perpendicular from the street to the front entry. Meandering walkways are discouraged, except where it is needed to avoid a tree. • Use paving materials that are similar to those used historically for the building style. Concrete, wood or sandstone may be appropriate for certain building styles. 1.10 Preserve historic elements of the yard to provide an appropriate context for historic structures. • The front yard should be maintained in a traditional manner, with planting material and sod, and not covered with paving, for example. 1.11 Preserve and maintain mature landscaping on site, particularly landmark trees and shrubs. • Protect established vegetation during construction to avoid damage. Replacement of damaged, aged or diseased trees must be approved by the Parks Department. • If a tree must be removed as part of the addition or alteration, replace it with species of a large enough scale to have a visual impact in the early years of the project. 1.12 Preserve and maintain historically significant planting designs. • Retaining historic planting beds, landscape features and walkways is encouraged. 1.13 Revisions or additions to the landscape should be consistent with the historic context of the site. • Select plant and tree material according to its mature size, to allow for the long-term impact of mature growth. • Reserve the use of exotic plants to small areas for accent. • Do not cover grassy areas with gravel, rock or paving materials. 1.14 Additions to the landscape that could interfere with historic structures are inappropriate. • Do not plant climbing ivy or trees too close to a building. New trees should be no closer than the mature canopy size. • Do not locate plants or trees in locations that will obscure significant architectural features or block views to the building. • It is not appropriate to plant a hedge row that will block views into the yard. Response: Mature trees are proposed to be retained during construction. A simple lawn and straight concrete walkway are proposed in the front yard to provide direct access from Hallam Street to the restored front porch. A secondary concrete paver walkway that is smaller in width than the main entrance with grass between the pavers is proposed along Fifth Street. Moveable seating and some planters are proposed in the yard facing Fifth Street in accordance with Zoning allowances. This corner lot does not have much yard space on the interior of the lot, so the outdoor area faces Fifth Street. This is largely driven by the dripline protection of the large cottonwood tree. Consistent with plantings associated with the time period of the historic resource, rose bushes and lilac shrubs are proposed as noted on the landscape plan (Sheet HPC 2.00). 1.15 Minimize the visual impacts of site lighting. • Site lighting should be shielded to avoid glare onto adjacent properties. Focus lighting on walks and entries, rather than up into trees and onto facade planes. Response: Site lighting is limited to entrance doors around the perimeter of the building. Short pathway lights are proposed in the patio area facing Fifth Street. Lighting shall meet the City Lighting Code. (Sheet EL-1.0) Exhibit A Final Design Review 2.7 Match the original material in composition, scale and finish when replacing materials on primary surfaces. • If the original material is wood clapboard, for example, then the replacement material must be wood as well. It should match the original in size, the amount of exposed lap and finish. • Replace only the amount required. If a few boards are damaged beyond repair, then only those should be replaced, not the entire wall. 2.8 Do not use synthetic materials as replacements for primary building materials. • In some instances, substitute materials may be used for replacing architectural details, but doing so is not encouraged. If it is necessary to use a new material, such as a fiberglass column, the style and detail should precisely match that of the historic model. • Primary building materials such as wood siding and brick should not be replaced with synthetic materials. • Synthetic materials include: aluminum, vinyl siding and panelized brick. • EIFS (synthetic stucco) is not an appropriate replacement for real stucco. Response: The areas of restoration, as shown on the approved demolition plan and determined by Staff and Monitor in the field, will match historic siding and original material. 3.1 Preserve the functional and decorative features of a historic window. • Features important to the character of a window include its frame, sash, muntins/mullions, sills, heads, jambs, moldings, operation and groupings of windows. • Repair frames and sashes rather than replacing them, whenever conditions permit. • Preserve the original glass, when feasible. 3.2 Preserve the position, number and arrangement of historic windows in a building wall. • Enclosing a historic window opening in a key character-defining facade is inappropriate, as is adding a new window opening. This is especially important on primary facades where the historic ratio of solid-to-void is a character-defining feature. • Greater flexibility in installing new windows may be considered on rear walls. • Do not reduce an original opening to accommodate a smaller window or door or increase it to receive a larger window on primary facades. 3.3 Preserve the historic ratio of window openings to solid wall on a facade. • Significantly increasing the amount of glass on a character-defining facade will negatively affect the integrity of a structure. 3.4 Match a replacement window to the original in its design. • If the original is double-hung, then the replacement window should also be double-hung, or at a minimum, appear to be so. Match the replacement also in the number and position of glass panes. • Matching the original design is particularly important on key character-defining facades. 3.5 In a replacement window, use materials that appear similar to the original. • Using the same material as the original is preferred, especially on character-defining facades. However, a substitute material may be considered if the appearance of the window components will match those of the original in dimension, profile and finish. Materials Windows Exhibit A Final Design Review 3.6 Preserve the size and proportion of a historic window opening. • Reducing an original opening to accommodate a smaller window or increasing it to receive a larger window is inappropriate. • Consider reopening and restoring an original window opening where altered. 3.7 Match, as closely as possible, the profile of the sash and its components to that of the original window. • A historic window often has a complex profile. Within the window's casing, the sash steps back to the plane of the glazing (glass) in several increments. These increments, which individually only measure in eighths or quarters of inches, are important details. They distinguish the actual window from the surrounding plane of the wall. Response: Original windows are retained and new windows in the landmark will be as close as possible to the historic profile and will be wood. Please refer to sheet HPC 3.08 for window details on the historic home. 4.1 Preserve historically significant doors. • Maintain features important to the character of a historic doorway. These may include the door, door frame, screen door, threshold, glass panes, paneling, hardware, detailing, transoms and flanking sidelights. • Do not change the position and function of original front doors and primary entrances. • If a secondary entrance must be sealed shut, any work that is done must be reversible so that the door can be used at a later time, if necessary. Also, keep the door in place, in its historic position. • If the secondary entrance is sealed shut, the original entrance on the primary facade must remain operable. 4.2 Maintain the original size of a door and its opening. • Altering its size and shape is inappropriate. It should not be widened or raised in height. 4.5 When replacing a door, use a design that has an appearance similar to the original door or a door associated with the style of the house. • A replica of the original, if evidence exists, is the preferred replacement. • A historic door from a similar building also may be considered. • Simple paneled doors were typical. • Very ornate doors, including stained or leaded glass, are discouraged, unless photographic evidence can support their use. Doors Exhibit A Final Design Review Response: An original door remains on the property at a secondary entry facing Fifth Street. The original door is proposed to be replicated on the front porch in location B. To meet guideline 4.5, a similar front entry door facing Hallam Street is proposed that has references to the original door style, but is a product of its own time. The existing shed door is proposed to remain on the shed. 5.1 Preserve an original porch. • Replace missing posts and railings when necessary. Match the original proportions and spacing of balusters when replacing missing ones. • Unless used historically on the property, wrought iron, especially the "licorice stick" style that emerged in the 1950s and 1960s, is inappropriate. • Expanding the size of a historic porch is inappropriate. 5.2 Avoid removing or covering historic materials and details on a porch. • Removing an original balustrade, for example, is inappropriate. 5.3 Avoid enclosing a historic front porch. • Keeping an open porch is preferred. • Enclosing a porch with opaque materials that destroy the openness and transparency of the porch is not acceptable. Porches Exhibit A Final Design Review • Enclosing porches with large areas of glass, thereby preserving the openness of the porch, may be considered in special circumstances. When this is done, the glass should be placed behind posts, balusters, and balustrade, so the original character of the porch may still be interpreted. • The use of plastic curtains as air-locks on porches is discouraged. • Reopening an enclosed porch is appropriate. 5.4 The use of a porch on a residential building in a single-family context is strongly encouraged. • This also applies to large, multifamily structures. There should be at least one primary entrance and should be identified with a porch or entry element. 5.5 If porch replacement is necessary, reconstruct it to match the original in form and detail. • Use materials that appear similar to the original. • While matching original materials is preferred, when detailed correctly and painted appropriately, alternative materials may be considered. • Where no evidence of the appearance of the historic porch exists, a new porch may be considered that is similar in character to those found on comparable buildings. Keep the style and form simple. Also, avoid applying decorative elements that are not known to have been used on the house or others like it. • When constructing a new porch, its depth should be in scale with the building. • The scale of porch columns also should be similar to that of the trimwork. • The height of the railing and the spacing of balusters should appear similar to those used historically as well. Response: The front porches are proposed to be restored to match historic photographs in accordance with the Guidelines listed above. Sheet HPC 3.10 show a detail of the front porch roof pitch and eave depth. A window is shown in the 1984 photo provided below, which indicates a window where the current door is located. The door is proposed to remain since it is unknown whether there was a door or a window in that location. Floor plans from the 1984 land use case (below) and the 1960s AHS photo (below) guide the restoration efforts of the front porches. Exhibit A Final Design Review 1984 Existing plans. 1960s Aspen Historical Society photo. 1984 photo showing window on interior wall. Exhibit A Final Design Review 6.1 Preserve significant architectural features. • Repair only those features that are deteriorated. • Patch, piece-in, splice, consolidate or otherwise upgrade the existing material, using recognized preservation methods whenever possible. • Isolated areas of damage may be stabilized or fixed, using consolidants. Epoxies and resins may be considered for wood repair and special masonry repair components also may be used. • Removing a damaged feature when it can be repaired is inappropriate. 6.2 When disassembly of a historic element is necessary for its restoration, use methods that minimize damage to the original material. • Document its location so it may be repositioned accurately. Always devise methods of replacing the disassembled material in its original configuration. 6.3 Remove only the portion of the detail that is deteriorated and must be replaced. • Match the original in composition, scale, and finish when replacing materials or features. • If the original detail was made of wood , for example, then the replacement material should be wood, when feasible. It should match the original in size and finish, which traditionally was a smooth painted finish. 6.4 Repair or replacement of missing or deteriorated features should be based on original designs. • The design should be substantiated by physical or pictorial evidence to avoid creating a misrepresentation of the building’s heritage. • When reconstruction of an element is impossible because there is no historical evidence, develop a compatible new design that is a simplified interpretation of the original, and maintains similar scale, proportion and material. 6.5 Do not guess at "historic" designs for replacement parts. • Where "scars" on the exterior suggest that architectural features existed, but there is no other physical or photographic evidence, then new features may be designed that are similar in character to related buildings. • Using overly ornate materials on a building for which there is no documentation is inappropriate. • It is acceptable to use salvaged materials from other buildings only if they are similar in style and detailing to other features on the building where they are to be installed. 6.6 Replacement of missing elements may be included in repair activities. • Replace only those portions that are beyond repair. • Replacement elements should be based on documented evidence. • Use the same kind of material as the original when feasible. • A substitute material may be acceptable if the form and design of the substitute itself conveys the visual appearance of the original material. For example, a fiberglass cornice may be considered at the top of a building. Response: All original architectural details are proposed to remain, unless beyond repair as determined in the field by staff and monitor. Replacement parts will be based on documentation and will be coordinated with staff and monitor. Architectural Details Exhibit A Final Design Review 7.1 Preserve the original form of a roof. • Do not alter the angle of a historic roof. Instead, maintain the perceived line and orientation of the roof as seen from the street. • Retain and repair roof detailing. 7.2 Preserve the original eave depth. • The shadows created by traditional overhangs contribute to one's perception of the building's historic scale and therefore, these overhangs should be preserved. 7.5 Preserve original chimneys, even if they are made non-functional. Response: The cross gable roof form was approved during Conceptual Review and is included in the Final Design application. Eave depth will match the historic portions of the building that remain and precedent for this type of one story landmark structure in Aspen, subject to staff and monitor review. No chimney is proposed, as there is no evidence or documentation of where the chimney was originally located. 7.8 Preserve original roof materials. • Avoid removing historic roofing material that is in good condition. When replacement is necessary, use a material that is similar to the original in both style as well as physical qualities and use a color that is similar to that seen historically. • Specialty materials such as tile, slate or concrete should be replaced with a matching material. 7.9 New or replacement roof materials should convey a scale, color and texture similar to those used traditionally. • Replacement materials should be similar to those used historically on comparably styled buildings. • If a substitute is used, such as composition shingle, the roof material should be earth tone and have a matte, non-reflective finish. • Flashing should be in scale with the roof material. • If copper flashing is to be used, it should be treated to establish a matte, non-reflective finish. Response: There are no original roof materials on the existing building – roof materials consist of asphalt shingles. A cedar shingle roof is proposed for the historic landmark, and the almost flat (and invisible to the pedestrian) front porch roof is proposed to be a membrane. Original roof rafters are proposed to remain where possible. 8.1 If an existing secondary structure is historically significant, then it must be preserved. • When treating a historic secondary building, respect its character-defining features. These include its primary and roof materials, roof form, windows, doors and architectural details. • If a secondary structure is not historically significant, then its preservation is optional. 8.2 If an existing secondary structure is beyond repair, then replacing it is encouraged. • An exact reconstruction of the secondary structure may not be necessary in these cases. Secondary Structures Roofs Materials Exhibit A Final Design Review • The replacement should be compatible with the overall character of the historic primary structure, while accommodating new uses. 8.3 Avoid attaching a garage or carport to the primary structure. • Traditionally, a garage was sited as a separate structure at the rear of the lot; this pattern should be maintained. Any proposal to attach an accessory structure is reviewed on a case-by-case basis. 8.4 A garage door should be compatible with the character of the historic structure. • A wood-clad hinged door is preferred on a historic structure. • If an overhead door is used, the materials should match that of the secondary structure. • If the existing doors are hinged, they can be adapted with an automatic opener. 8.5 Avoid moving a historic secondary structure from its original location. • A secondary structure may only be repositioned on its original site to preserve its historic integrity. Response: The secondary structure, aka the garden shed, is about 5 x 6 in size and its sits within the side yard setback. The structure is not shown on the Sanborn Maps, but has been indicated by Planning Staff to be of historic value to the property. It is approved to be located near the alley and Fifth Street. It will be stabilized as needed when placed in its new location. 9.5 A new foundation should appear similar in design and materials to the historic foundation. • On modest structures, a simple foundation is appropriate. Constructing a stone foundation on a modest miner's cottage is discouraged because it would be out of character. • Where a stone foundation was used historically, and is to be replaced, the replacement should be similar in the cut of the stone and design of the mortar joints. 9.6 When rebuilding a foundation, locate the structure at its approximate historic elevation above grade. • Raising the building slightly above its original elevation is acceptable. However, lifting it substantially above the ground level is inappropriate. • Changing the historic elevation is discouraged, unless it can be demonstrated that it enhances the resource. Response: The foundation material will be a concrete scratch coat to match existing. The relationship of grade to the historic home will be similar to its historic grade. Positive drainage and creating an interior space that does not have any steps on the ground level result from the minor changes to existing grade. According to the 1964 photograph, the existing sloping grade is not the historic grade documented in the photograph. 10.3 Design a new addition such that one's ability to interpret the historic character of the primary building is maintained. • A new addition that creates an appearance inconsistent with the historic character of the primary building is inappropriate. New Additions Foundation Exhibit A Final Design Review • An addition that seeks to imply an earlier period than that of the primary building also is inappropriate. • An addition that seeks to imply an inaccurate variation of the primary building's historic style should be avoided. • An addition that covers historically significant features is inappropriate. 10.4 Design a new addition to be recognized as a product of its own time. • An addition should be made distinguishable from the historic building, while also remaining visually compatible with these earlier features. • A change in setbacks of the addition from the historic building, a subtle change in material or a differentiation between historic, and more current styles are all techniques that may be considered to help define a change from old to new construction. 10.11 On a new addition, use exterior materials that are compatible with the historic materials of the primary building. • The new materials should be either similar or subordinate to the original materials. Response: The new addition has similar form and fenestration to the landmark but the architectural detailing is proposed to be slightly different. The architectural details in the gable ends and the roof overhangs of the new addition create a subtle distinction between new and old construction that does not distract from the landmark or confuse the public. Windows in the addition are all vertically oriented and comprise mostly double hung windows ganged together to represent a product of its own time and to contrast and to highlight the single double hung windows in the landmark. Window sashes in the addition are proposed to be metal clad. The doors in the addition are full light glass doors that contrast the historic doors in the landmark to clearly represent the addition as a product of its own time. Restoration of the landmark and the removal of non-historic additions are proposed to enhance the historic significance of the structure. Exterior materials for the new construction include a narrow horizontal wood siding as the primary material and a channel lap wood siding and metal panel cladding as a secondary material on the connecting element and parts of the new addition (Sheet HPC 3.06). 14.3 Keep color schemes simple. • Using one base color for the building is preferred. • Using only one or two accent colors is also encouraged, except where precedent exists for using more than two colors with some architectural styles. 14.4 Coordinating the entire building in one color scheme is usually more successful than working with a variety of palettes. • Using the color scheme to establish a sense of overall composition for the building is strongly encouraged. 14.5 Develop a color scheme for the entire building front that coordinates all the facade elements. Color – Advisory Only Exhibit A Final Design Review • Choose a base color that will link the entire building face together. For a commercial building, it can tie signs, ornamentation, awnings and entrances together. On residences, it can function similarly. It can also help your building relate better to others in the district. • The complexity of the accent colors should be appropriate to the architectural style of the building. • Doors may be painted a bright accent color, or they may be left a natural wood finish. Historically, many of the doors would have simply had a stain applied. • Window sashes are also an excellent opportunity for accent color. • Brilliant luminescent or “day-glo” colors are not appropriate. Response: The proposed color palette is white with dark accents colors. The color scheme is simple and the same for both the landmark and new addition. 14.6 Exterior lights should be simple in character and similar in color and intensity to that used traditionally. • The design of a fixture should be simple in form and detail. Exterior lighting must be approved by the HPC. • All exterior light sources should have a low level of luminescence. 14.7 Minimize the visual impacts of site and architectural lighting. • Unshielded, high intensity light sources and those which direct light upward will not be permitted. • Shield lighting associated with service areas, parking lots and parking structures. • Timers or activity switches may be required to prevent unnecessary sources of light by controlling the length of time that exterior lights are in use late at night. • Do not wash an entire building facade in light. • Avoid placing exposed light fixtures in highly visible locations, such as on the upper walls of buildings. • Avoid duplicating fixtures. For example, do not use two fixtures that light the same area. 14.8 Minimize the visual impact of light spill from a building. • Prevent glare onto adjacent properties by using shielded and focused light sources that direct light onto the ground. The use of downlights, with the bulb fully enclosed within the shade, or step lights which direct light only on to walkways, is strongly encouraged. • Lighting shall be carefully located so as not to shine into residential living space, on or off the property or into public rights-of-way. Response: Exterior lights and locations are provided on Sheet EL-1.0 in the drawing set. Simple fixtures are proposed that meet the Lighting Code and minimize visual impact of light spill from the building. All lights are downward facing. Lighting Exhibit A Final Design Review 14.17 Design a new driveway in a manner that minimizes its visual impact. • Plan parking areas and driveways in a manner that utilizes existing curb cuts. New curb cuts are not permitted. • If an alley exists, a new driveway must be located off of it. 14.18 Garages should not dominate the street scene. 14.19 Use a paving material that will distinguish the driveway from the street. • Using a change in material, paving pattern or texture will help to differentiate the driveway from the street. • Porous paving materials will also help to absorb potential water runoff typically associated with impervious surfaces such as asphalt or concrete. Response: The proposed driveway is very short and accesses a two car garage off of the alleyway. A simple concrete apron is proposed as the driveway material. Driveways i IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII RECEPTION#: 647044, R: $43.00, D: $0.00 DOC CODE: RESOLUTION Pg 1 of 7, 05/02/2018 at 11:29:34 AM Janice K.Vos Caudill, Pitkin County, CO A RESOLUTION OF THE ASPEN HISTORIC PRESERVATION COMMISSION (HPC) GRANTING CONCEPTUAL MAJOR DEVELOPMENT, DEMOLITION, RELOCATION,AND VARIATIONS FOR THE PROPERTY LOCATED AT 533 WEST HALLAM STREET, LOTS A & B, BLOCK 29,CITY AND TOWNSITE OF ASPEN, COLORADO RESOLUTION #4, SERIES OF 2018 PARCEL ID: 2735-124-32-001 WHEREAS, the applicant, Duncan Skihaus, LLC, represented by BendonAdams, LLC., has requested HPC approval for Conceptual, Major Development, Demolition, Relocation, and Variations for the property located at 533 West Hallam Street, Lots A & B, Block 29, City and Townsite of Aspen, Colorado; and WHEREAS, Section 26.415.070 of the Municipal Code states that "no building or structure shall be erected, constructed, enlarged, altered, repaired, relocated or improved involving a designated historic property or district until plans or sufficient information have been submitted to the Community Development Director and approved in accordance with the procedures established for their review;"and WHEREAS, for Conceptual Major Development Review, the HPC must review the application, a staff analysis report and the evidence presented at a hearing to determine the project's conformance with the City of Aspen Historic Preservation Design Guidelines per Section 26.415.070.D.3.b.2 and 3 of the Municipal Code and other applicable Code Sections. The HPC may approve, disapprove, approve with conditions or continue the application to obtain additional information necessary to make a decision to approve or deny; and WHEREAS, for approval of Demolition, the application shall meet the requirements of Aspen Municipal Code Section 26.415.080.A, Demolition of a Designated Property; and WHEREAS, for approval of Relocation, the application shall meet the requirements of Aspen Municipal Code Section 26.415.090.C,Relocation of a Designated Property; and WHEREAS, the HPC may approve setback variations according to Section 26.415.11 O.C.La, Variances; and WHEREAS,the HPC may approve variations to the Residential Design Standards according to Section 26.410.010.General or for reasons of fairness; and WHEREAS, the HPC may approve a floor area bonus according to Section 26.415.1107, Floor area bonus; and WHEREAS, HPC reviewed the project on November 9, 2017, March 14, 2018 and April 11, 2018. HPC considered the application, the staff memo and public comments, and found the HPC Resolution 44, Series of 2018 Page 1 of 3 Exhibit B proposal consistent with the review standards and granted approval with conditions by a vote of 5to0. NOW, THEREFORE, BE IT RESOLVED: That HPC hereby approves Conceptual Major Development, Demolition, Relocation, and Variation review for 533 W. Hallam Street (Version 4.1) presented on April 11, 2018 with the following conditions: 1. HPC hereby grants the following dimensional variations: a. A 3'-O" reduction of the rear yard setback for the garage. b. A 8'-0" reduction of the rear yard setback for the above grade building, lightwells, basement, and outbuilding. c. A P-9"reduction of the west side yard setback to allow for the historic outbuilding. d. A2'-0"reduction of the east side yard setback to allow for the lightwells. e. A 8'-9" reduction of the combined side yard setback to allow for the historic outbuilding and lightwells. If any discrepancies are identified, then we will refer to floor plans submitted in version 4.1. 2. HPC hereby grants a 500 sq. ft Floor Area Bonus. 3. The landscape plan found in this April 1 1 m application has not been reviewed nor approved, but a developed landscape plan, including any alteration to grade or visible features associated with stromwater mitigation, will be reviewed for approval during Final Review. No visible features pertaining to stormwater, such as drywells, are to be in the foreground of the historic resource. 4. As part of a building permit review, the applicant will be required to submit a report from a licensed engineer, architect or housemover demonstrating that the house and outbuilding can be moved, and the method for moving and protecting the structures, must be submitted with the building permit application. In addition the applicant must provide a bond, letter of credit or cashier's check in the amount of $30,000 to be held by the City during the duration of the relocation process, and $15,000 for the relocation of the outbuilding. 5. A development application for a Final Development Plan shall be submitted within one (1) year of the date of approval of a Conceptual Development Plan. Failure to file such an application within this time period shall render null and void the approval of the Conceptual Development Plan. The Historic Preservation Commission may, at its sole discretion and for good cause shown, grant a one-time extension of the expiration date for a Conceptual Development Plan approval for up to six (6) months provided a written request for extension is received no less than thirty(30)days prior to the expiration date. HPC Resolution#4, Series of 2018 Page 2 of 3 APPROVED BY THE COMMISSION at its regular meeting on the 11°i day of April, 2018. Approved as to Fo Approved as to Contcnt: (^ Andrea Wan,Assistant City Attorney Gr en Green hair AATTT E ST: Nicole Henning, Deputy City lerk ATTACHMENT: Version 4.1 floor plans (Sheets: HPC 203, HPC 204, HPC 205,HPC 206) HPC Resolution 44, Series of 2018 Page 3 of 3 il!COO YSSia lit,I, O Y RRRRR U ilt!t Hill r------------------------------------------------------- I I I I I I I I I I I I I I I I C 6 I i I i I I i e i I I 3 a I M ]I I Q i j a II x e i I a7 MN F oa x w CD gM Qi f dg o - 2RkRR H U it l;il; i iii uraolu I I I I I I ewe a—• I I 1 qYW NW3 I Wpl ltllxl I a 1 I • 1 I y Y 11 I 5FL ii e 1= I I I' I I. 3 I I I rq yY II z I I L,71 I I O I ffil_ 171117 II I QI I c s c I Z I I a w Q e,,,, n<I sl I a I I --- II x N. c . e ------- -------------------------- -- - ° o f------ M d IxIIAIYLOW FF f0 x X W I y SS•a j ll!I. y Y YYBN m. d f iilj' d p names y N i1 li; ! I I I I I ISI F=\ zI j I I I I I I I i i I i I I I I I i I i I I Ii I I IIII j I I I i i i I i I II I T j-iI w-iTi 1,'i`i 1 ii 77ii:,ii—,T I i i S I i a I I I I III i I i I Z j IIN'llllllll i 94 w II e I mI iIF, a I I o I w L______--_—___—_—_—____- J F tC x k W tl coo s43J 7 LI. r SO a mun- I I I I I n---- I I I I 1¢ I I I I I 64- I I I I I I i I i I I I I I I I I I IIII I i I Q I i I a I i i I CL I i i I a F I o x Ell I I ow a; M O un usaove F oa x w HP – Major Development Final 533 W. Hallam Street 2735-124-32-001 CITY OF ASPEN PRE-APPLICATION CONFERENCE SUMMARY PLANNER: Sarah Yoon, 970.920.5144 DATE: May 01, 2018 PROJECT: 533 W. Hallam Street REPRESENTATIVE: Poss Architecture and Planning, BendonAdams REQUEST: HPC Review – Major Development Final Review DESCRIPTION: The Conceptual Design for 533 W. Hallam was approved for restoration, a new addition, and preservation benefits by HPC on April 11, 2018. City Council did not request call-up on April 30, 2018 when project was presented. HPC approval is needed for Final Development Review which focuses on landscape, lighting and materials. The approved resolution at Conceptual Design does specify conditions regarding the placement of the stormwater features that will need to be represented clearly in the Final Review documents for HPC approval. HPC will use the Historic Preservation Design Guidelines and the Land Use Code Sections that are applicable to this project to assist with their determinations. Relevant Land Use Code Section(s): 26.304 Common Development Review Procedures 26.415 Historic Preservation 26.415.070.D.4 Historic Preservation – Major Development, Final Review 26.415.080 Historic Preservation – Demolition 26.415.090 Historic Preservation – Relocation 26.415.110 Historic Preservation - Benefits 26.575.020 Calculations and Measurements 26.610 Impact fees 26.710.040 Medium-Density Residential (R-6) Zone District Below are links to the Land Use Application form and Land Use Code for your convenience: Land Use Code: http://cityofaspen.com/276/Title-26-Land-Use-Code HPC Design Guidelines: https://www.cityofaspen.com/DocumentCenter/Home/View/310 Land Use Application: http://cityofaspen.com/DocumentCenter/Home/View/305 Review by: Staff for completeness and recommendation, HPC for decision. Public Hearing: Yes, at HPC. Neighborhood Outreach: No. Referral Agencies: None. Planning Fees: $1,950 for 6 billable hours of staff time. (Additional/lesser hours will be billed/refunded at a rate of $325 per hour.) Referral Agencies Fee: $0. Total Deposit: $1,950. Exhibit C 2 Please submit the completed application to the Community Development Office on the Third Floor of City Hall:  Completed Land Use Application and signed fee agreement.  Pre-application Conference Summary (this document).  Street address and legal description of the parcel on which development is proposed to occur, consisting of a current (no older than 6 months) certificate from a title insurance company, an ownership and encumbrance report, or attorney licensed to practice in the State of Colorado, listing the names of all owners of the property, and all mortgages, judgments, liens, easements, contracts and agreements affecting the parcel, and demonstrating the owner’s right to apply for the Development Application.  Applicant’s name, address and telephone number in a letter signed by the applicant that states the name, address and telephone number of the representative authorized to act on behalf of the applicant.  List of adjacent property owners within 300’ for public hearing.  HOA Compliance form (Attached).  Site improvement survey including topography and vegetation showing the current status, including all easements and vacated rights of way, of the parcel certified by a registered land surveyor, licensed in the state of Colorado. (This requirement, or any part thereof, may be waived by the Community Development Department if the project is determined not to warrant a survey document.)  A written explanation of the proposal and how the proposal complies with the review standards relevant to the Final Development application.  Scaled drawings of all proposed structure(s) or addition(s) depicting their form, including their height, massing, scale, proportions and roof plan; and the primary features of all elevations. Drawings need to clearly label areas being restored and/or altered.  Supplemental materials to provide a visual description of the context surrounding the designated historic property or historic district including at least one (1) of the following: diagrams, maps, photographs, models or streetscape elevation.  ¼” scaled drawings of all street facing facades.  Final selection of all exterior materials, and samples or clearly illustrated photographs. Samples are preferred for the presentation to HPC.  Final landscape plan including irrigation plans and any grade alterations related to stormwater mitigation. No stormwater features are permitted in the foreground of the historic resource (Resolution 4, Series of 2018).  Final lighting plan for all exterior fixtures with cut sheets. 3 Once the copy is deemed complete by staff, the following items will then need to be submitted:  1 digital PDF copy of the complete application packet  12 sets of all graphics printed at 11x17  Total deposit for review of the application. Disclaimer: The foregoing summary is advisory in nature only and is not binding on the City. The summary is based on current zoning, which is subject to change in the future, and upon factual representations that may or may not be accurate. The summary does not create a legal or vested right. CITY OF ASPEN COMMUNITY DEVELOPMENT DEPARTMENT March, 2016 City of Apen|130 S. Galena St.|(970) 920 5050 ATTACHMENT 3 DIMENSIONAL REQUIREMENTS FORM Project: ______________________________________________________________________________ Applicant: ______________________________________________________________________________ Location: ______________________________________________________________________________ Zone District: ______________________________________________________________________________ Lot Size: _______________________________________________________________________________ Lot Area: _______________________________________________________________________________ (For the purpose of calculating Floor Area, Lot Area may be reduced for areas within the high-water mark, easement, and steep slopes. Please refer to the definition of Lot Area in the Municipal Code.) Commercial net leasable: Existing: _____________ Proposed: _________________________________ Number of residential units: Existing: _____________ Proposed: _________________________________ Number of bedrooms: Existing: _____________ Proposed: _________________________________ Proposed % of demolition (Historic properties only): ______________ DIMENSIONS: Floor Area: Existing: _____________ Allowable: ___________Proposed ____________ Principal bldg. height: Existing: _____________ Allowable: ___________Proposed____________ Access. Bldg. height: Existing: _____________ Allowable: __________ Proposed_____________ On-Site parking: Existing: _____________ Required: ___________Proposed_____________ % Site coverage: Existing: _____________ Required: ___________Proposed_____________ % Open Space: Existing: _____________ Required: ___________Proposed_____________ Front Setback: Existing: _____________ Required ____________Proposed _____________ Rear Setback: Existing: _____________ Required: ___________Proposed _____________ Combined F/F: Existing: _____________ Required ___________ Proposed _____________ Side Setback: Existing: _____________ Required: ___________Proposed ___________ Side Setback: Existing: _____________ Required ___________ Proposed ____________ Combined Sides: Existing: _____________ Required ___________ Proposed _____________ Distance between Bldgs. Existing: _____________ Required: ___________ Proposed _____ ____ Existing: _____________ Required: ___________Proposed: _____________ Existing non-conformities or encroachments: __________________________________________________ _______________________________________________________________________________________ Variations requested: _____________________________________________________________________ _______________________________________________________________________________________ _______________________________________________________________________________________ 533 West Hallam Street Lots A & B, Block 29, City and Townsite of Aspen R-6 6,000 sf 6,000 sf n/a1 1 n/a 3240sf + 500sf Bonus = 3740 sf 25 ft n/a 2 spaces 50% n/a 10 ft. 10 ft/5ft n/a 5 ft. min. 5 ft. min. 15 ft. 5 ft. 2 garden sheds sit in west side setback, rear yard setback encroachment. Duncan Skihaus LLC 4 5 74% 2,427 3,740 22'-7"22'-9 3/8" 2 spaces 2 spaces 35%56.8% 10 ft 10 ft 5 ft 2 ft 5 ft 10 ft 1'9" ft for shed & 12' 2" for bldg 15' ft 8'9" ft reduction 7'-10" Exhibit D setback variances requested - please refer to application for detailed description. 74.9% 21'-5 1/2" 43.8%44.6% 3,517 44.7% 21'-4 1/8" 3,740 2' reduction east for lightwells City of Aspen Community Development Department Aspen Historic Preservation Land Use Packet City of Aspen|130 S. Galena Street.| (970) 920 5090 Historic Land Use Application Requirements, Updated: March 2016 ATTACHMENT 2 - Historic Preservation Land Use Application PROJECT: Name: Location: (Indicate street address, lot & block number or metes and bounds description of property) Parcel ID # (REQUIRED)___________________________________________________________ Applicant: Name: Address: Phone #: _______________________Fax#:___________________E-mail:_______________________________________________ REPRESENTATIVE: Name: Address: Phone #: _______________________Fax#:___________________E-mail:________________________________________________ TYPE OF APPLICATION: (please check all that apply): Historic Designation Certificate of No Negative Effect Certificate of Appropriateness -Minor Historic Development -Major Historic Development -Conceptual Historic Development -Final Historic Development -Substantial Amendment Relocation (temporary, on or off-site) Demolition (total demolition) Historic Landmark Lot Split EXISTING CONDITIONS: (description of existing buildings, uses, previous approvals, etc.) ___________________________________________________________________________________________________________ PROPOSAL: (description of proposed buildings, uses, modifications, etc.) ________________________________________________________________________________________________________ 533 West Hallam Street Lots A & B, Block 29, City and Townsite of Aspen CO 2735-124-32-001 Duncan Skihaus LLC 600 Travis #3550, Houston TX 77002 BendonAdams & Poss Architecture and Planning BA: 300 S. Spring Street, Aspen/ Poss: 605 E. Main Street, Aspen 970-925-2855 x2 sara@bendonadams; awisnoski@billposs.com single family residence with non-historic additions and alterations. Small garden shed in west side setback. single family residence with new addition. Restoration of front facade of landmark. City of Aspen Community Development Department Aspen Historic Preservation Land Use Packet City of Aspen|130 S. Galena Street.| (970) 920 5090 Historic Land Use Application Requirements, Updated: March 2016 General Information Please check the appropriate boxes below and submit this page along with your application. This information will help us review your plans and, if necessary, coordinate with other agencies that may be involved. YES NO  Does the work you are planning include exterior work; including additions, demolitions, new construction, remodeling, rehabilitation or restoration?  Does the work you are planning include interior work, including remodeling, rehabilitation, or restoration?  Do you plan other future changes or improvements that could be reviewed at this time?  In addition to City of Aspen approval for a Certificate of Appropriateness or No Negative Effect and a building permit, are you seeking to meet the Secretary of the Interior’s Standards for Rehabilitation or restoration of a National Register of Historic Places Property in order to qualify for state or federal tax credits?  If yes, are you seeking federal rehabilitation investment tax credits in Conjunction with this project? (Only income producing properties listed on the National Register are eligible. Owner-occupied residential properties are not.)  If yes, are you seeking the Colorado State Income Tax Credit for Historical Preservation? Please check all City of Aspen Historic Preservation Benefits which you plan to use:  Rehabilitation Loan Fund  Conservation Easement Program  Dimensional Variances  Increased Density  Historic Landmark Lot Split  Waiver of Park Dedication Fees  Conditional Uses  Tax Credits  Exemption from Growth Management Quota System 323 314334 207310320 320 304 300 323 317 307 310 323329 420 426 315 518 401 327331518518 447 501511 433 431 421 417 407 403 210 330 520 437 513 517 120 204 333 442 504 500 501 340 617627633 616 616 612 604 620 605609617631635 630634 225 709 716 718 307 634 630 624 620 610 609615621633 701 601 205 602 525 504 506520 530 404 426430 434 520522530 523533 323 533 401 407 411425 420 318 432 317 319 500 407 309 529 PD P R-6 533 W. Hallam Vicinity Map Sources: Esri, HERE, DeLorme, Intermap, increment P Corp., GEBCO,USGS, FAO, NPS, NRCAN, GeoBase, IGN, Kadaster NL, Ordnance Survey, October 2, 2017 0 0.035 0.070.0175 mi 0 0.04 0.080.02 km 1:2,257 Exhibit E Exhibit F Land Title Guarantee Company Customer Distribution PREVENT FRAUD - Please remember to call a member of our closing team when initiating a wire transfer or providing wiring instructions. Order Number:Q62008788 Date: 10/11/2017 Property Address:533 W HALLAM STREET, ASPEN, CO 81611 PLEASE CONTACT YOUR CLOSER OR CLOSER'S ASSISTANT FOR WIRE TRANSFER INSTRUCTIONS For Closing Assistance Closer's Assistant For Title Assistance Kimberly Parham 533 E HOPKINS #102 ASPEN, CO 81611 (970) 925-1678 (Work) (303) 393-4870 (Work Fax) kparham@ltgc.com Contact License: CO414945 Company License: CO44565 Nikki Durrett 533 E HOPKINS #102 ASPEN, CO 81611 (970) 925-1678 (Work) (800) 318-8202 (Work Fax) ndurrett@ltgc.com Company License: CO44565 Roaring Fork Valley Title Team 533 E HOPKINS #102 ASPEN, CO 81611 (970) 927-0405 (Work) (970) 925-0610 (Work Fax) valleyresponse@ltgc.com Seller/Owner DUNCAN SKIHAUS, LLC, A WYOMING LIMITED LIABILITY COMPANY Attention: CHARLES W. DUNCAN, III Delivered via: Electronic Mail SARA ADAMS Attention: SARA ADAMS sara@bendonadams.com Delivered via: Electronic Mail BERTHOUD LEGAL Attention: JANET berthoudlegal@gmail.com Delivered via: Electronic Mail Exhibit G Land Title Guarantee Company Estima te of Title Fe es Order Number:Q62008788 Date: 10/11/2017 Property Address:533 W HALLAM STREET, ASPEN, CO 81611 Parties:TO BE DETERMINED Seller:DUNCAN SKIHAUS, LLC, A WYOM ING LIMITED LIABILITY COMPANY Vis it Land Title's Webs ite at www.ltgc.com for direc tions to any of our offic es . Estimate of Title insurance Fees "TBD" Comm itm ent $216.00 Total $216.00 If Land Title Guarantee Company will be clos ing this transaction, the fees lis ted abov e will be c ollec ted at c losing. Thank you for your order! CHAIN OF TITLE DOCUMENTS:Pitkin county recorded 03/07/2017 under reception no. 636621 Copyright 2006-2017 Am erican Land Title Association. All rights reserved. The use of this Form is restricted to ALTA licensees and ALTA mem bers in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the Am erican Land Title Association. Customer Ref-Loan No.: Property Address: 533 W HALLAM STREET, ASPEN, CO 81611 1.Effective Date: 09/20/2017 at 5:00 P.M. 2.Policy to be Issued and Proposed Insured: "TBD" Com mitment Proposed Insured: TO BE DETERMINED $0.00 3.The estate or interest in the land described or referred to in this Commitment and covered herein is: A Fee Simple 4.Title to the estate or interest covered herein is at the effective date hereof vested in: DUNCAN SKIHAUS, LLC, A WYOMING LIMITED LIABILITY COM PANY 5.The Land referred to in this Commitment is described as follows: LOTS A AND B, BLOCK 29, CITY AND TOWNSITE OF ASPEN, COUNTY OF PITKIN, STATE OF COLORADO. ALTA COMMITMENT Old R epublic N ational Title Insurance Company Schedule A Order Number:Q62008788 This proposed Insured must notify the Company in writing of the name of any party not referred to in this Commitment who will obtain an interest in the Land or who will make a loan on the Land. The Company may then make additional Requirements or Exceptions. Pay the agreed amount for the estate or interest to be insured. Pay the premiums, fees, and charges for the Policy to the Company. Documents satisfactory to the Company that convey the Title or create the M ortgage to be insured, or both, must be properly authorized, executed, delivered, and recorded in the Public Records. 1.LAND TITLE GUARANTEE COMPANY HAS RECEIVED AN IM PROVEM ENT LOCATION CERTIFICATE/SURVEY FOR THE SUBJECT PROPERTY PREPARED BY SOPRIS ENGINEERING LLC, JOB NO. 15126.01, DATED JUNE 18, 2015, THAT IS ACCEPTABLE TO THE COM PANY. *** IN ADDITION, A SURVEY AFFIDAVIT, EXECUTED BY DUNCAN SKIHAUS, LLC, A WYOM ING LIM ITED LIABILITY COMPANY, IS NECESSARY INDICATING THAT THERE HAVE BEEN NO NEW IM PROVEM ENTS, EASEMENTS OR BOUNDARY CHANGES SINCE THE DATE OF SAID IMPROVEMENT LOCATION CERTIFICATE/SURVEY AND THAT THE IMPROVEMENTS SHOWN ON SAID IM PROVEM ENT LOCATION CERTIFICATE/SURVEY HAVE NOT BEEN ALTERED SINCE THE DATE OF SAID IMPROVEMENT LOCATION CERTIFICATE/SURVEY. *** 2.EVIDENCE SATISFACTORY TO THE COM PANY THAT THE TERMS, CONDITIONS AND PROVISIONS OF THE CITY OF ASPEN TRANSFER TAX HAVE BEEN SATISFIED. 3.RELEASE OF DEED OF TRUST DATED M ARCH 06, 2017 FROM DUNCAN SKIHAUS, LLC, A WYOMING LIM ITED LIABILITY COMPANY TO THE PUBLIC TRUSTEE OF PITKIN COUNTY FOR THE USE OF M ORTGAGE ELECTRONIC REGISTRATION SYSTEM S, INC. ACTING SOLELY AS NOMINEE FOR BANK OF AM ERICA TO SECURE THE SUM OF $3,500,000.00 RECORDED MARCH 07, 2017, UNDER RECEPTION NO. 636623. 4.A FULL COPY OF THE FULLY EXECUTED OPERATING AGREEM ENT AND ANY AND ALL AM ENDMENTS THERETO FOR DUNCAN SKIHAUS, LLC, A WYOM ING LIM ITED LIABILITY COMPANY MUST BE FURNISHED TO LAND TITLE GUARANTEE COM PANY. SAID AGREEM ENT MUST DISCLOSE WHO MAY CONVEY, ACQUIRE, ENCUM BER, LEASE OR OTHERWISE DEAL WITH INTERESTS IN REAL PROPERTY FOR SAID ENTITY. NOTE: ADDITIONAL REQUIREMENTS M AY BE NECESSARY UPON REVIEW OF THIS DOCUMENTATION. ALTA COMMITMENT Old R epublic N ational Title Insurance Company Schedule B , Part I (R equirements) Order Number: Q62008788 All of the following Requirements must be met: 5.WRITTEN CONFIRM ATION THAT THE INFORMATION CONTAINED IN STATEM ENT OF AUTHORITY FOR DUNCAN SKIHAUS, LLC, A WYOM ING LIM ITED LIABILITY COMPANY RECORDED M ARCH 07, 2017 AT RECEPTION NO. 636622 IS CURRENT. NOTE: SAID INSTRUMENT DISCLOSES CHARLES W. DUNCAN, III AND LESLIE R. DUNCAN AS THE M EMBERS AUTHORIZED TO EXECUTE INSTRUMENTS CONVEYING, ENCUM BERING OR OTHERWISE AFFECTING TITLE TO REAL PROPERTY ON BEHALF OF SAID ENTITY. IF THIS INFORM ATION IS NOT ACCURATE, A CURRENT STATEMENT OF AUTHORITY M UST BE RECORDED. 6.WARRANTY DEED FROM DUNCAN SKIHAUS, LLC, A WYOMING LIMITED LIABILITY COM PANY TO TO BE DETERMINED CONVEYING SUBJECT PROPERTY. NOTE: ADDITIONAL REQUIREMENTS OR EXCEPTIONS M AY BE NECESSARY WHEN THE BUYERS NAMES ARE ADDED TO THIS COM MITMENT. COVERAGES AND/OR CHARGES REFLECTED HEREIN, IF ANY, ARE SUBJECT TO CHANGE UPON RECEIPT OF THE CONTRACT TO BUY AND SELL REAL ESTATE AND ANY AMENDM ENTS THERETO. ALTA COMMITMENT Old R epublic N ational Title Insurance Company Schedule B , Part I (R equirements) Order Number: Q62008788 All of the following Requirements must be met: This commitment does not republish any covenants, condition, restriction, or limitation contained in any document referred to in this commitment to the extent that the specific covenant, conditions, restriction, or limitation violates state or federal law based on race, color, religion, sex, sexual orientation, gender identity, handicap, familial status, or national origin. 1.Any facts, rights, interests, or claims thereof, not shown by the Public Records but that could be ascertained by an inspection of the Land or that may be asserted by persons in possession of the Land. 2.Easements, liens or encumbrances, or claims thereof, not shown by the Public Records. 3.Any encroachment, encumbrance, violation, variation, or adverse circumstance affecting the Title that would be disclosed by an accurate and complete land survey of the Land and not shown by the Public Records. 4.Any lien, or right to a lien, for services, labor or material heretofore or hereafter furnished, imposed by law and not shown by the Public Records. 5.Defects, liens, encumbrances, adverse claims or other matters, if any, created, first appearing in the public records or attaching subsequent to the effective date hereof but prior to the date of the proposed insured acquires of record for value the estate or interest or mortgage thereon covered by this Commitment. 6.(a) Taxes or assessments that are not shown as existing liens by the records of any taxing authority that levies taxes or assessments on real property or by the Public Records; (b) proceedings by a public agency that may result in taxes or assessments, or notices of such proceedings, whether or not shown by the records of such agency or by the Public Records. 7.(a) Unpatented mining claims; (b) reservations or exceptions in patents or in Acts authorizing the issuance thereof; (c) water rights, claims or title to water. 8.RESERVATIONS AND EXCEPTIONS AS SET FORTH IN DEED FROM THE CITY OF ASPEN RECORDED DECEM BER 5, 1887 IN BOOK 59 AT PAGE 122, "THAT NO TITLE SHALL BE HEREBY ACQUIRED TO ANY M INE OF GOLD, SILVER, CINNABAR OR COPPER OR TO ANY VALID M INING CLAIM OR POSSESSION HELD UNDER EXISTING LAWS". 9.M ATTERS DISCLOSED ON IM PROVEM ENT SURVEY PLAT PREPARED BY SOPRIS ENGINEERING, LLC CERTIFIED JUNE 18, 2015, INCLUDING, BUT NOT LIM ITED TO THE EFFECT OF THE SHED, OUT BUILDING, PAVERS, DECK, CONCRETE AND LANDSCAPE TIM BERS BEING BUILT OUTSIDE OF THE BUILDING SETBACK, THE WIRE FENCE BUILT ONTO HALLAM STREET AND THE DUMPSTER ON SKIDS ENCROACHING ONTO BLOCK 29. SAID DOCUM ENT STORED AS OUR ESI 31995545. ALTA COMMITMENT Old R epublic N ational Title Insurance Company Schedule B , Part II (Exceptions) Order Number: Q62008788 LAND TITLE GUARANTEE COMPANY DISCLOSURE STATEMENTS Note: Pursuant to CRS 10-11-122, notice is hereby given that: Note: Effective Septem ber 1, 1997, CRS 30-10-406 requires that all documents received for recording or filing in the clerk and recorder's office shall contain a top margin of at least one inch and a left, right and bottom m argin of at least one half of an inch. The clerk and recorder m ay refuse to record or file any document that does not conform, except that, the requirem ent for the top m argin shall not apply to docum ents using forms on which space is provided for recording or filing information at the top margin of the docum ent. Note: Colorado Division of Insurance Regulations 8-1-2 requires that "Every title entity shall be responsible for all m atters which appear of record prior to the tim e of recording whenever the title entity conducts the closing and is responsible for recording or filing of legal docum ents resulting from the transaction which was closed". Provided that Land Title Guarantee Com pany conducts the closing of the insured transaction and is responsible for recording the legal documents from the transaction, exception num ber 5 will not appear on the Owner's Title Policy and the Lenders Policy when issued. Note: Affirmative mechanic's lien protection for the Owner may be available (typically by deletion of Exception no. 4 of Schedule B, Section 2 of the Com mitment from the Owner's Policy to be issued) upon compliance with the following conditions: No coverage will be given under any circumstances for labor or m aterial for which the insured has contracted for or agreed to pay. Note: Pursuant to CRS 10-11-123, notice is hereby given: The Subject real property may be located in a special taxing district.(A) A certificate of taxes due listing each taxing jurisdiction will be obtained from the county treasurer of the county in which the real property is located or that county treasurer's authorized agent unless the proposed insured provides written instructions to the contrary. (for an Owner's Policy of Title Insurance pertaining to a sale of residential real property). (B) The inform ation regarding special districts and the boundaries of such districts may be obtained from the Board of County Comm issioners, the County Clerk and Recorder, or the County Assessor. (C) The land described in Schedule A of this com mitment m ust be a single family residence which includes a condominium or townhouse unit. (A) No labor or materials have been furnished by mechanics or m aterial-men for purposes of construction on the land described in Schedule A of this Comm itm ent within the past 6 m onths. (B) The Company m ust receive an appropriate affidait indemnifying the Company against un-filed m echanic's and material-m en's liens. (C) The Company m ust receive payment of the appropriate prem ium .(D) If there has been construction, improvements or major repairs undertaken on the property to be purchased within six months prior to the Date of Comm itm ent, the requirem ents to obtain coverage for unrecorded liens will include: disclosure of certain construction inform ation; financial information as to the seller, the builder and or the contractor; payment of the appropriate prem ium fully executed Indemnity Agreem ents satisfactory to the company, and, any additional requirements as m ay be necessary after an examination of the aforesaid inform ation by the Company. (E) This notice applies to owner's policy comm itm ents disclosing that a m ineral estate has been severed from the surface estate, in Schedule B-2. Note: Pursuant to CRS 10-1-128(6)(a), It is unlawful to knowingly provide false, incomplete, or m isleading facts or information to an insurance company for the purpose of defrauding or attempting to defraud the com pany. Penalties may include im prisonment, fines, denial of insurance, and civil dam ages. Any insurance company or agent of an insurance company who knowingly provides false, incom plete, or misleading facts or inform ation to a policyholder or claimant for the purpose of defrauding or attempting to defraud the policyholder or claimant with regard to a settlement or award payable from insurance proceeds shall be reported to the Colorado Division of Insurance within the Department of Regulatory Agencies. Note: Pursuant to Colorado Division of Insurance Regulations 8-1-3, notice is hereby given of the availability of a closing protection letter for the lender, purchaser, lessee or seller in connection with this transaction. That there is recorded evidence that a mineral estate has been severed, leased, or otherwise conveyed from the surface estate and that there is substantial likelihood that a third party holds som e or all interest in oil, gas, other minerals, or geothermal energy in the property; and (A) That such m ineral estate m ay include the right to enter and use the property without the surface owner's permission.(B) JOINT NOTICE OF PRIVACY POLICY OF LAND TITLE GUARANTEE COMPANY, LAND TITLE GUARANTEE COMPANY OF SUMMIT COUNTY LAND TITLE INSURANCE CORPORATION AND OLD REPUBLIC NATIONAL TITLE INSURANCE COMPANY This Statement is provided to you as a customer of Land Title Guarantee Com pany and Meridian Land Title, LLC, as agents for Land Title Insurance Corporation and Old Republic National Title Insurance Com pany. We want you to know that we recognize and respect your privacy expectations and the requirem ents of federal and state privacy laws. Inform ation security is one of our highest priorities. We recognize that m aintaining your trust and confidence is the bedrock of our business. We m aintain and regularly review internal and external safeguards against unauthorized access to non-public personal inform ation ("Personal Information"). In the course of our business, we may collect Personal Information about you from : applications or other forms we receive from you, including com munications sent through TM X, our web-based transaction managem ent system; your transactions with, or from the services being perform ed by us, our affiliates, or others; a consumer reporting agency, if such information is provided to us in connection with your transaction; and The public records m aintained by governm ental entities that we either obtain directly from those entities, or from our affiliates and non-affiliates. Our policies regarding the protection of the confidentiality and security of your Personal Inform ation are as follows: We restrict access to all Personal Information about you to those employees who need to know that information in order to provide products and services to you. We maintain physical, electronic and procedural safeguards that comply with federal standards to protect your Personal Inform ation from unauthorized access or intrusion. Employees who violate our strict policies and procedures regarding privacy are subject to disciplinary action. We regularly assess security standards and procedures to protect against unauthorized access to Personal Inform ation. WE DO NOT DISCLOSE ANY PERSONAL INFORM ATION ABOUT YOU WITH ANYONE FOR ANY PURPOSE THAT IS NOT PERM ITTED BY LAW. Consistent with applicable privacy laws, there are som e situations in which Personal Information may be disclosed. We may disclose your Personal Inform ation when you direct or give us perm ission; when we are required by law to do so, for example, if we are served a subpoena; or when we suspect fraudulent or criminal activities. We also m ay disclose your Personal Inform ation when otherwise permitted by applicable privacy laws such as, for example, when disclosure is needed to enforce our rights arising out of any agreement, transaction or relationship with you. Our policy regarding dispute resolution is as follows: Any controversy or claim arising out of or relating to our privacy policy, or the breach thereof, shall be settled by arbitration in accordance with the rules of the American Arbitration Association, and judgm ent upon the award rendered by the arbitrator(s) may be entered in any court having jurisdiction thereof. Commitment For Title Insurance Iss ued by Old Re public National Title Insuranc e Corporation NOTICE IMPORTANT—READ CAREFULLY: THIS COMMITMENT IS AN OFFER TO ISSUE ONE OR MORE TITLE INSURANCE POLICIES. ALL CLAIMS OR REMEDIES SOUGHT AGAINST THE COMPANY INVOLVING THE CONTENT OF THIS COMMITMENT OR THE POLICY MUST BE BASED SOLELY IN CONTRACT. THIS COMMITMENT IS NOT AN ABSTRACT OF TITLE, REPORT OF THE CONDITION OF TITLE, LEGAL OPINION, OPINION OF TITLE, OR OTHER REPRESENTATION OF THE STATUS OF TITLE. THE PROCEDURES USED BY THE COMPANY TO DETERMINE INSURABILITY OF THE TITLE, INCLUDING ANY SEARCH AND EXAMINATION, ARE PROPRIETARY TO THE COMPANY, WERE PERFORMED SOLELY FOR THE BENEFIT OF THE COMPANY, AND CREATE NO EXTRACONTRACTUAL LIABILITY TO ANY PERSON, INCLUDING A PROPOSED INSURED. THE COMPANY’S OBLIGATION UNDER THIS COMMITMENT IS TO ISSUE A POLICY TO A PROPOSED INSURED IDENTIFIED IN SCHEDULE A IN ACCORDANCE WITH THE TERMS AND PROVISIONS OF THIS COMMITMENT. THE COMPANY HAS NO LIABILITY OR OBLIGATION INVOLVING THE CONTENT OF THIS COMMITMENT TO ANY OTHER PERSON. . COMMITMENT TO ISSUE POLICY Subject to the Notice; Schedule B, Part I—Requirements; Schedule B, Part II—Exceptions; and the Commitment Conditions, Old Republic National Title Insurance Company, a Minnesota corporation (the “Company”), commits to issue the Policy according to the terms and provisions of this Commitment. This Commitment is effective as of the Commitment Date shown in Schedule A for each Policy described in Schedule A, only when the Company has entered in Schedule A both the specified dollar amount as the Proposed Policy Amount and the name of the Proposed Insured. If all of the Schedule B, Part I—Requirements have not been met within 6 months after the Commitment Date, this Commitment terminates and the Company’s liability and obligation end. CO MMITMENT CONDITIONS 1. DEFINITIONS 2. If all of the Schedule B, Part I—Requirements have not been met within the time period specified in the Commitment to Issue Policy, Comitment terminates and the Company’s liability and obligation end. 3. The Company’s liability and obligation is limited by and this Commitment is not valid without: 4. COMPANY’S RIGHT TO AMEND The Company may amend this Commitment at any time. If the Company amends this Commitment to add a defect, lien, encumbrance, adverse claim, or other matter recorded in the Public Records prior to the Commitment Date, any liability of the Company is limited by Commitment Condition 5. The Company shall not be liable for any other amendment to this Commitment. 5. LIMITATIONS OF LIABILITY i. comply with the Schedule B, Part I—Requirements; ii. eliminate, with the Company’s written consent, any Schedule B, Part II—Exceptions; or iii. acquire the Title or create the Mortgage covered by this Commitment. “Knowledge” or “Known”: Actual or imputed knowledge, but not constructive notice imparted by the Public Records.(a) “Land”: The land described in Schedule A and affixed improvements that by law constitute real property. The term “Land” does include any property beyond the lines of the area described in Schedule A, nor any right, title, interest, estate, or not easement in abutting streets, roads, avenues, alleys, lanes, ways, or waterways, but this does not modify or limit the extent that a right of access to and from the Land is to be insured by the Policy. (b) “Mortgage”: A mortgage, deed of trust, or other security instrument, including one evidenced by electronic means authorized by law.(c) “Policy”: Each contract of title insurance, in a form adopted by the American Land Title Association, issued or to be issued by the Company pursuant to this Commitment. (d) “Proposed Insured”: Each person identified in Schedule A as the Proposed Insured of each Policy to be issued pursuant to this Commitment.(e) “Proposed Policy Amount”: Each dollar amount specified in Schedule A as the Proposed Policy Amount of each Policy to be issued pursuant to this Commitment. (f) “Public Records”: Records established under state statutes at the Commitment Date for the purpose of imparting constructive notice of matters relating to real property to purchasers for value and without Knowledge. (g) “Title”: The estate or interest described in Schedule A.(h) the Notice;(a) the Commitment to Issue Policy;(b) the Commitment Conditions;(c) Schedule A;(d) Schedule B, Part I—Requirements; and(e) Schedule B, Part II—Exceptions[; and(f) a counter-signature by the Company or its issuing agent that may be in electronic form.(g) The Company’s liability under Commitment Condition 4 is limited to the Proposed Insured’s actual expense incurred in the interval between the Company’s delivery to the Proposed Insured of the Commitment and the delivery of the amended Commitment, resulting from the Proposed Insured’s good faith reliance to: (a) The Company shall not be liable under Commitment Condition 5(a) if the Proposed Insured requested the amendment or had Knowledge of the matter and did not notify the Company about it in writing. (b) The Company will only have liability under Commitment Condition 4 if the Proposed Insured would not have incurred the expense had the Commitment included the added matter when the Commitment was first delivered to the Proposed Insured. (c) The Company’s liability shall not exceed the lesser of the Proposed Insured’s actual expense incurred in good faith and described in Commitment(d) 6. LIABILITY OF THE COMPANY MUST BE BASED ON THIS COMMITMENT 7. IF THIS COMMITMENT HAS BEEN ISSUED BY AN ISSUING AGENT The issuing agent is the Company’s agent only for the limited purpose of issuing title insurance commitments and policies. The issuing agent is not the Company’s agent for the purpose of providing closing or settlement services. 8. PRO-FORMA POLICY The Company may provide, at the request of a Proposed Insured, a pro-forma policy illustrating the coverage that the Company may provide. A pro-forma policy neither reflects the status of Title at the time that the pro-forma policy is delivered to a Proposed Insured, nor is it a commitment to insure. 9. ARBITRATION The Policy contains an arbitration clause. All arbitrable matters when the Proposed Policy Amount is $2,000,000 or less shall be arbitrated at the option of either the Company or the Proposed Insured as the exclusive remedy of the parties. A Proposed Insured may review a copy of the arbitration rules at http://www.alta.org/arbitration. IN WITNESS WHEREOF, Land Title Insurance Corporation has caused its corporate name and seal to be affixed by its duly authorized officers on the date shown in Schedule A to be valid when countersigned by a validating officer or other authorized signatory. Issued by: Land Title Guarantee Com pany 3033 East First Avenue Suite 600 Denver, Colorado 80206 303-321-1880 President Old Republic National Title Insurance Company, a Stock Com pany 400 Second Avenue South Minneapolis, Minnesota 55401 (612)371-1111 Mark Bilbrey, President Rande Yeager, Secretary This page is only a part of a 2016 ALTA® Commitment for Title Insurance issued by Land Title Insurance Corporation. This Commitment is not valid without the Notice; the Commitment to Issue Policy; the Commitment Conditions; Schedule A; Schedule B, Part I—Requirements; and Schedule B, Part II—Exceptions; and a counter-signature by the Company or its issuing agent that may be in electronic form. Copyright 2006-2016 American Land Title Association. All rights reserved. The use of this Form (or any derivative thereof) is restricted to ALTA licensees and ALTA members in good standing as of the date of use. All other uses are prohibited. Reprinted under license from the American Land Title Association. Conditions 5(a)(i) through 5(a)(iii) or the Proposed Policy Amount. The Company shall not be liable for the content of the Transaction Identification Data, if any.(e) In no event shall the Company be obligated to issue the Policy referred to in this Commitment unless all of the Schedule B, Part I—Requirements have been met to the satisfaction of the Company. (f) In any event, the Company’s liability is limited by the terms and provisions of the Policy.(g) Only a Proposed Insured identified in Schedule A, and no other person, may make a claim under this Commitment.(a) Any claim must be based in contract and must be restricted solely to the terms and provisions of this Commitment.(b) Until the Policy is issued, this Commitment, as last revised, is the exclusive and entire agreement between the parties with respect to the subject matter of this Commitment and supersedes all prior commitment negotiations, representations, and proposals of any kind, whether written or oral, express or implied, relating to the subject matter of this Commitment. (c) The deletion or modification of any Schedule B, Part II—Exception does not constitute an agreement or obligation to provide coverage beyond the terms and provisions of this Commitment or the Policy. (d) Any amendment or endorsement to this Commitment must be in writing and authenticated by a person authorized by the Company.(e) When the Policy is issued, all liability and obligation under this Commitment will end and the Company’s only liability will be under the Policy.(f) Exhibit H 1950 6 Exhibit I Pitkin County Mailing List of 300 Feet Radius Pitkin County GIS presents the information and data on this web site as a service to the public. Every effort has been made to ensure that the information and data contained in this electronic system is accurate, but the accuracy may change. Mineral estate ownership is not included in this mailing list. Pitkin County does not maintain a database of mineral estate owners. Pitkin County GIS makes no warranty or guarantee concerning the completeness, accuracy, or reliability of the content at this site or at other sites to which we link. Assessing accuracy and reliability of information and data is the sole responsibility of the user. The user understands he or she is solely responsible and liable for use, modification, or distribution of any information or data obtained on this web site. This document contains a Mailing List formatted to be printed on Avery 5160 Labels. If printing, DO NOT "fit to page" or "shrink oversized pages." This will manipulate the margins such that they no longer line up on the labels sheet. Print actual size. From Parcel: 273512432001 on 07/12/2018 Instructions: Disclaimer: http://www.pitkinmapsandmore.com Exhibit J FERGUS ELIZABETH DAWSON ASPEN, CO 81612 PO BOX 1515 PDT PARTNERS LLC NEW YORK, NY 10024 209 W 78TH ST NATIONWIDE THEATRES CORP CARLSBAD, CA 92018 PO BOX 847 SCHWARTZ RACHEL K & MARK BLOOMFIELD HILLS, MI 483042603 1061 COUNTRY CLUB RD MCCAUSLAND LINDA REV TRUST ASPEN, CO 81611 609 W FRANCIS ST BLEEKER STREET PROP LLC LOS ANGELES, CA 90049 PO BOX 491246 CLARKS ADDITION CONDO ASSOC ASPEN, CO 81611 COMMON AREA 317 N FOURTH ST HALLAM WEST END LLC ASPEN, CO 81611 625 E MAIN ST # 102B-141 SHELBY LLC DENVER, CO 80218 1201 WILLIAMS ST #6 STONEHILL PROPERTIES LLC SANTA MONICA, CA 90402 2517 LA MESA DR CITY OF ASPEN ASPEN, CO 81611 130 S GALENA ST HILLMAN TATNALL L REV TRUST ASPEN, CO 81611 504 W BLEEKER ST BLAICH JANET S TRUST ASPEN, CO 81611 319 N FOURTH ST MAGGOS LAURA P ASPEN, CO 81611 317 NORTH 4TH ST 530 HALLAM LLC ASPEN, CO 81611 623 E HOPKINS HENRY KRISTEN ASPEN, CO 81611-1246 525 W HALLAM ST COOK ROBERT C & MARSHA N ASPEN, CO 81611 621 W FRANCIS ST 529 W FRANCIS LLC ASPEN, CO 81611 625 E HYMAN AVE # 201 COOK ROBERT C & MARSHA N ASPEN, CO 81611 621 W FRANCIS ST MACDONALD BETTE S TRUST ENGLEWOOD, CO 80110 15 BLACKMER RD COLLETT JOHN & VIRGINIA C CHARLOTTE, NC 28204 1111 METROPOLITAN AVE #700 LAST RUN HOLDINGS LLC NEW YORK, NY 10023 115 CENTRAL PARK WEST # 12G 323 NORTH 5TH ST LLC HOUSTON, TX 77019 2219 BRENTWOOD DR FISCHER SISTIE ASPEN, CO 81611 442 W BLEEKER FELD ANNE S DALLAS, TX 75201 1700 PACIFIC AVE #4100 CONNERY FAMILY TRUST LARKSPUR, CA 949391345 135 WARD ST MINERS CABIN LLC ASPEN, CO 81611 620 W HALLAM BLAICH ROBERT I TRUST ASPEN, CO 81611 319 N FOURTH ST BRAY FAMILY TRUST DALLAS, TX 75219 3899 MAPLE AVE # 300 530 HALLAM LLC ASPEN, CO 81611 623 E HOPKINS ASPEN HISTORICAL SOCIETY ASPEN, CO 81611 620 W BLEEKER ST WARE NINA COULTER LIV TRUST SAINT LOUISI, MO 68146 13021 KING ARTHUR SPUR GLENN SALLY RAE ASPEN, CO 81611 504 W HALLAM AVE EGGLESTON ROBERT H JR & TRACY H ASPEN, CO 81611 434 W HALLAM 501 WEST HALLAM LLC VAIL , CO 81658 PO BOX 3389 BLEEKER STREET PROP LLC LOS ANGELES, CA 90049 PO BOX 491246 605 W BLEEKER LLC MONROE, CT 06468 PO BOX 5010 HILLMAN DORA B TRUST ASPEN, CO 81611 504 W BLEEKER WOGAN WENDY ASPEN, CO 81611 533 W FRANCIS ST REEDS HOUSE CONDO ASSOC ASPEN, CO 81611 COMMON AREA 621 W FRANCIS ST LARNER GLEN & TRACY L HOUSTON, TX 77027 3737 ELLA LEE LN MEMORANDUM TO: Sara Yoon CC: William Lewis Sara Bendon Chris Fris Joseph Edward FROM: Alex Ewers, P.E. DATE: August 31, 2018 RE: Stormwater Summary for HPC Review of 533 W Hallam Attachments: Drainage Report for Duncan Skihaus 533 W. Hallam Street, Aspen, CO SGM is responsible for providing civil engineering services for the redevelopment of 533 W Hallam including a drainage design to meet City of Aspen requirements as outlined in the City of Aspen Urban Runoff Management Plan (URMP). 533 W Hallam is also known as “Duncan Skihaus”. This memo is a supplement to the previously submitted Drainage Report for Duncan Skihaus, 533 W. Hallam Street, Aspen, CO dated July, 2018. Water Quality Treatment Features The two types of features being proposed to treat stormwater runoff for this project are grass buffers and pervious pavers. These features, or “Best Management Practices” (BMPs), are discussed in sections 8.5.1.3 and 8.5.1.4, respectively of the URMP. These BMPs were chosen because of their effectiveness, low maintenance, and inconspicuous appearance. Grass Buffers Grass buffers will be used to treat approximately 26% of onsite stormwater runoff. Grass buffers consist of densely vegetated turf grass that runoff will flow over uniformly. Grass buffers are effective at trapping sediment from stormwater runoff thus improving the quality of water before it flows offsite. The grass buffers will be located either outside the pervious pavers or landscaped areas thus acting as a secondary treatment method for runoff. The buffers will also slow the flow of runoff and reduce the runoff volume and peak flow through infiltration. Grading of the landscaped areas and the pervious pavers will be uniform, so runoff is not concentrated over the buffer. Allowing runoff to flow uniformly over the grass buffer area allows for effective infiltration and trapping of sediment. exhibit L Grass buffers are an aesthetically pleasing stormwater BMP that are easily maintained. Typical landscaping needs will provide for adequate maintenance of the system with the occasional removal and replacement of certain areas that have accumulated sediment. Minimal irrigation will be provided to allow for healthy vegetation coverage without overwatering. With minimal irrigation the buffer area will not be continuously saturated which will allow for better infiltration of runoff. Stormwater BMP’s that require more frequent maintenance can often be neglected and become failing systems. Grass buffers were selected due to the ease of maintenance, overall effectiveness, and aesthetics that they provide. Pervious Pavers Modular Block Pavement (or pervious pavers) will be used to treat the remaining 74% of onsite stormwater runoff. Pervious pavers are concrete block units with voids that occupy at least 20% of the surface area. These voids are then filled with sand. Runoff will percolate though the void spaces and then an additional 3 inches of sand below the pavers which will provide similar treatment as a sand filter. After percolating through the sand layer, runoff will be enter a 6-inch gravel layer and will then infiltrate into native soils. An additional benefit of the pervious paver system is the reduction of stormwater runoff volumes and peak flows through infiltration. Pervious pavers are advantageous due to their ability for high levels of removal for particulate pollutants. The addition of the 6-inch gravel base below the sand will act as a reservoir for lager storms and promote infiltration. Along with the grass buffers, pervious pavers can be aesthetically pleasing with the wide variety of patterns and colors available. Runoff from the house will infiltrate through the pervious pavers into the sand filter zone. After the stormwater is filtered through the sand, it is routed to a gravel layer to promote infiltration as shown in the schematic drawing below. Some of the pavers are located over the basement where the thickness of the sand layer has been maximized to promote filtration. Figure 1: Pervious Paver Profile View City of Aspen Urban Runoff Management Plan Compliance The proposed drainage plan for 533 W. Hallam St is designed based on the City of Aspen URMP requirements. The BMP’s have been slightly oversized to provide for treatment of larger storms. For more detailed stormwater routing information and calculations, please see the Drainage Report for Duncan Skihaus, 533 W. Hallam Street, Aspen, CO. DRAINAGE REPORT FOR DUNCAN SKIHAUS 533 W. HALLAM STREET, ASPEN, CO. July, 2018 Prepared by 118 West Sixth Street, Suite 200 Glenwood Springs, CO 81601 970.945.1004 970.945.5948 fax 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design i TABLE OF CONTENTS 1.0 Existing Site 2 1.1 Description of Existing Site 2 1.2 Description of Existing Drainage 2 2.0 Proposed Project 2 3.0 Proposed Basins 3 3.1 Basin A (subbasins 1 & 2) 3 Subbasin 1 4 Subbasin 2 4 3.2 Basin B (subbasin 3) 4 3.3 Basin C (subbasin 4 & 6) 4 Subbasin 4 5 Subbasin 6 5 3.4 Basin D (subbasins 5 & 7) 5 Subbasin 5 6 Subbasin 7 6 4.0 Peak Flow Methodology 7 5.0 Water Quality Methodology 7 6.0 Maintenance 8 6.1 Grass Buffer Maintenance 8 6.2 Pervious Pavers 9 7.0 Conclusion 10 LIST OF APPENDICES Appendix A – Proposed Drainage Routing Schematic Appendix B – Water Quality Capture Volume Calculations Appendix C – Peak Flow Calculations – Proposed Conditions 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design 2 1.0 Existing Site 1.1 Description of Existing Site The physical address of the project is 533 W. Hallam Street, Aspen, Colorado and it is located on parcel no. 2735-124-32-001. This parcel is approximately 0.14 acres and is owned by Duncan Skihaus LLC. Current zoning of the property is medium-density residential (R-6). The existing structures on the parcel are one house and a small shed. The project focuses on renovating the house while preserving the historic portion of it. The existing house is 1897 square feet and has two stories with a garage located near the Block 29 alley. 1.2 Description of Existing Drainage Existing stormwater runs off of several areas of the existing house either as sheet flow or through gutters and downspouts. On the west and north sides of the site, runoff sheet flows over grass to the curb and gutter on W. Hallam & 5th St. Runoff on the east side of the building enters the neighboring property. Stormwater on the south side of the property enters the alley. No stormwater detention or treatment BMPs have been found on the site. There is no existing offsite runoff that enters the property. Existing peak flow calculations have not been provided for this report because detention is not required and runoff will not cross any other properties before discharging to the City of Aspen (COA) storm sewer system. 2.0 Proposed Project The primary purpose of this project is to demolish and rebuild the non-historic portion of the existing house. Other improvements include the addition of onsite snowmelt and improving stormwater runoff quality. The proposed project is considered a major project as defined by the COA Urban Runoff Management Plan (URMP) because more than 1000 square feet will be disturbed. The proposed residential development with have a footprint of 3160 square feet. The historical portion of the property, which has a footprint of 900 square feet, will be moved north but will remain intact. The main building will be located on the southern portion of the lot with a footprint of 2260 square feet. The main building’s footprint includes a paved area that connects the historical portion of the house with the main building. Stormwater quality improvements will be added through the use of 799 square feet of grass buffer and 1130 square feet of pervious pavers. The grass buffers will be located on the northern and south- western portion of the lot. The pervious pavers will be located on the western central and eastern central portions of the lot. No stormwater generated on the site will flow across the property line on the eastern portion of the lot into the neighboring residential lot. Runoff from the eastern side of the lot will flow to north through grading and will not be allowed to cross the property line through the use of a shoring wall that will be exposed slightly above grade. 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design 3 3.0 Proposed Basins The proposed site has 7 subbasins, as shown in Appendix A. To clearly describe these subbasins, they have been grouped into 4 basins based on shared discharge locations and water quality treatment. Stormwater runoff will be routed to designated BMPs for water quality treatment through a combination of grading and gutters with downspouts. A summary of the basins can be seen below in Table 1. All proposed stormwater runoff will discharge from the site as sheet flow to W. Hallam & 5th St. Table 1 – Basin Summary Basin Name Impervious Area Required WQCV (cf) Treatment Type(s) Treatment Area(s) (sf) Canopy Credit (sf) Available WQCV (cf) Utilized Available WQCV A 480.8 8.3 Grass Buffer, Pervious Pavers 308, 35 126 8.4 99% B 588.8 10.1 Grass Buffer, Pervious Pavers 199, 206 28 11.0 92% C 841.1 12.9 Grass Buffer, Pervious Pavers 56, 399 61 14.0 92% D 1253.5 21.4 Grass Buffer, Pervious Pavers 237, 490 179 24.0 89% 3.1 Basin A (subbasins 1 & 2) Basin A is located on the north side of the site generally between the property line and the Duncan Skihaus building with additional drainage from the front of the roof. Subbasins 1 and 2 are located in Basin A. The size and shape of this basin will change slightly between the existing and proposed conditions due to the relocation of the historic portion of Duncan Skihaus. This basin is 1334 square feet of which 481 square feet is impervious. Tree canopy credit is calculated per section 8.4.1 of the COA URMP in the table below. A grass buffer and pervious pavers will be used to treat the remaining WQCV. The proposed grass buffer is 308 square feet and the proposed pavers are 35 square ft. Table 2 Basin A Total Area (sf) 1334 Impervious Area (sf) 481 % Impervious 36% WQCV (cf) 8 Tree Canopy Credit (sf) 126 Pervious Paver Area (sf) 35 Grass Buffer Area (sf) 308 Effective Impervious Area (sf) -23 Effective WQCV req'd (cf) 0 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design 4 Subbasin 1 Subbasin 1 is located in the very north-east corner of the property. Subbasin 1 has a total and impervious area of 664 and 249 square feet, respectively. This corresponds to 38% impervious area for the subbasin. This area is mostly a grassed area with the north-eastern portion of the roof included. Stormwater will be routed from the roof to a grass buffer and pervious pavers via sheet flow and then north to the curb and gutter on W. Hallam St. Subbasin 2 Subbasin 2 is located in the very north-west corner of the property. Subbasin 2 has a total and impervious area of 670 and 232 square feet, respectively. This corresponds to 35% impervious area for the subbasin. This area is mostly a grassed area with the north-western portion of the roof included. Stormwater will be routed from the roof to a grass buffer via sheet flow and then north to the curb and gutter on W. Hallam St. 3.2 Basin B (subbasin 3) Basin B is located on the north-east side of the site and will collect runoff from the back side of the roof of the historic house and the north end of the proposed structure. Subbasin 3 is the only subbasin located in Basin B. Stormwater runoff will flow off the two roof areas over pervious pavers and then to an additional grass buffer area on the front lawn. This basin is 957 square feet of which 616 square feet is impervious. Pervious pavers and a grass buffer will be used to treat the remaining WQCV. The proposed pervious pavers are 206 square feet and the grass buffer is 199 square feet. Table 3 Basin B Total Area (sf) 957 Impervious Area (sf) 616 % Impervious 64% WQCV (cf) 10 Tree Canopy Credit (sf) 28 Pervious Paver Area (sf) 206 Grass Buffer Area (sf) 199 Effective Impervious Area (sf) -23 Effective WQCV req'd (cf) -0.2 The resulting effective impervious area is -23 square feet. Due to space availability additional treatment was generated by oversizing the grass buffer and pervious pavers. 3.3 Basin C (subbasin 4 & 6) Basin C is located on the north-west side of the site and will collect runoff from the back side of the roof for the historic property and the north end of the proposed structure. Basin C consists of subbasins 4 and 6. Stormwater will be routed from both roofed areas to pervious 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design 5 pavers and then to the curb and gutter on 5th St. This basin is 1559 square feet of which 841 square feet is impervious. 399 square feet of pervious pavers and a 56 square foot grass buffer will be used to treat the rest of the stormwater runoff. Table 4 Basin C Total Area (sf) 1559 Impervious Area (sf) 814 % Impervious 54% WQCV (cf) 9 Tree Canopy Credit (sf) 61 Pervious Paver Area (sf) 401.7 Grass Buffer Area (sf) 0 Effective Impervious Area (sf) -73 Effective WQCV req'd (cf) -1 The resulting effective impervious area is -73 square feet. Due to space availability additional treatment was generated by oversizing the pervious paver area. Subbasin 4 Subbasin 4 is located on the west-central portion of the property. Subbasin 4 has a total and impervious area of 1118 and 518 square feet, respectively. This corresponds to 46% impervious area for the subbasin. All stormwater in subbasin 4 will be routed by grading to the 399 square feet of pervious pavers and 56 square feet of grass buffer that are located just below and to the west of the impervious roof surface. Subbasin 6 Subbasin 6 is located on the east-central portion of the property. Subbasin 6 has a total and impervious area of 442 and 323 square feet, respectively. This corresponds to 73% impervious area for the subbasin. All stormwater in subbasin 6 will be routed through the proposed house, per the plumbing plans, to the pervious pavers and grass buffer located in subbasin 4. 3.4 Basin D (subbasins 5 & 7) Basin D is located on the southern half of the site and will collect runoff from the majority of the proposed house’s roof. Subbasins 5 and 7 are located in Basin D. Stormwater will be routed from the roof to a grass buffer and pervious pavers mostly located in Subbasin 5 on the south-west side of the site. Because of the location of subbasin 7, downspouts will be used to route runoff from subbasin 7 to the pervious pavers. Runoff will then sheet flow to the curb and gutter on 5th St. This basin is 2148 square feet of which 1254 square feet is impervious. A grass buffer and pervious pavers will be used to treat the remaining WQCV. 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design 6 The proposed grass buffer is 237 square feet and the proposed pervious pavers cover 490 square feet. Table 5 Basin D Total Area (sf) 2148 Impervious Area (sf) 1254 % Impervious 58% WQCV (cf) 21 Tree Canopy Credit (sf) 179 Pervious Paver Area (sf) 490 Grass Buffer Area (sf) 237 Effective Impervious Area (sf) -142 Effective WQCV req'd (cf) -3 The resulting effective impervious area is -142 square feet. Due to space availability additional treatment was generated by oversizing the BMPs utilized. Subbasin 5 Subbasin 5 is located on the west side of the property and extends from the middle of the property to near the southern most extent of the site. Subbasin 5 has a total and impervious area of 1314 and 667 square feet, respectively. This corresponds to 51% impervious area for the subbasin. The roof is on the east side of the subbasin and flow is routed from the roof to a grass buffer and pervious pavers below. Subbasin 7 Subbasin 7 is located on the southern portion of the property and extends from the western most extend to the eastern. Subbasin 7 has a total and impervious area of 834 and 587 square feet, respectively. This corresponds to 70% impervious area for the subbasin. This subbasin is adjacent to the Block 29 alley to the south and has a garage located on the eastern side. Runoff generated will not be conveyed through the alley. The runoff from subbasin 7 will be routed by grading and downspouts and gutters to the pervious pavers and the grass buffer located in subbasin 5 and the 192 square feet of pervious pavers in subbasin 7. 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design 7 4.0 Peak Flow Methodology Proposed drainage flow rates were determined using the rational method as explained in section 3.4 of the URMP and rainfall characteristics as explained in section 2 of the URMP. The rational method calculations can be seen in Appendix C. The following tables list the parameters that were used and the results determined for proposed conditions. Table 6 Watershed Characteristics Imperviousness Overland Flow Time (min) Channel Flow Time (min) Time of Concentration (min) Max Watershed Length (ft) Watershed Slope (ft/ft) C5 53% 9.9 0 9.9 100 0.025 0.36 Table 7 Proposed Conditions for 10-Year Storm C - Hydro Group B (URMP 3.4.2) I (in/hr) URMP Eq 2-1 A - (acres) Contributing Area Q (cfs) 0.43 2.9 0.14 0.17 Table 8 Proposed Conditions for 100-Year Storm C - Hydro Group B (URMP 3.4.2) I (in/hr) URMP Eq 2-1 A - (acres) Contributing Area Q (cfs) 0.54 4.7 0.14 0.35 For the calculation of proposed peak flows, the entire property was modeled as one subbasin. It was assumed that modeling the site as one subbasin was adequate due to the small size of the property, and that all runoff generated will be overland flow. It was also assumed that there would be no channelized flow on the property. There could be channelized flow on the east side if runoff was routed to this area, but flow will not be routed to the east. The hydrologic group was determined to be B from Figure 3.1 of the URMP. The intensity for the 10-year and 100-year storm were determined using Equation 2-1 of the URMP. 5.0 Water Quality Methodology The WQCV for the grass buffer and pervious pavers was determined by using the percent imperviousness and total area for each subbasin. The WQCV calculations can be seen in Appendix B of this report. Tree Canopy Credit was calculated as described in section 8.4.1 of the URMP and the calculations can be seen in Section 3. Runoff from all impervious areas will be treated by directing the runoff over a grass buffer or pervious paver. Some water from subbasins 1,2, 3, 4, 5, 6, and 7 are treated by directing runoff over a grass buffer that is equal in size to the impervious area to be treated as directed in section 8.5.1.3 of the URMP. The remaining runoff from subbasins 1, 3, 4, 5, 6, and 7 are treated by directing runoff over pervious pavers that are half the surface area of the impervious area to be treated as directed in section 8.5.1.4 of the URMP. 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design 8 6.0 Maintenance 6.1 Grass Buffer Maintenance The following maintenance recommendations were found in the Urban Drainage Flood Control District USDCM: Volume 3 Stormwater Quality (page 6-5 to 6-7) and will be used as a guide for the maintenance of the proposed grass buffer. Grass buffers should be inspected at least twice a year for cover and vehicle impacts. Trash and debris should be removed from the buffer at least twice a year. The buffer should be aerated once a year with holes of 2 inches in depth and no more than four inches apart. When aerating the buffer, sprinkler heads and shallow utilities should be marked to ensure they are not damaged. It is recommended to mow only when weeds need to be removed in the first 3 years. After the first 3 years the grass should be maintained at 6 inches or more in height. Additional information on mowing the grass buffer is provided in Figure 1. Irrigation is recommended to maintain a healthy vegetation cover. In the early summer and fall, irrigation is typically needed less, but in July and August more irrigation is needed. If native grasses are used, irrigation should not be needed after establishment but could be useful during long dry periods. Although irrigation is necessary for the establishment of the grass buffer, overwatering could cause uneven growth and should be avoided. Every year the irrigation system should be drained and blownout before the first winter freeze. The irrigation system should be inspected before reactivation in the spring. Fertilizers and herbicides should be used only on an as-needed basis and it is recommended to use biodegradable nontoxic fertilizers and herbicides. 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design 9 Figure 1: UDFCD Volume 3 - Mowing Recommendations for Grass Buffers 6.2 Pervious Pavers The following maintenance recommendations were found in the Urban Drainage Flood Control District USDCM: Volume 3 Stormwater Quality (page 6-15 to 6-17) and will be used as a guide for the maintenance of the proposed pervious pavers. An inspection of the condition and observation of infiltration should be completed annually. The pavers will lose infiltration capabilities over time and it is recommended to use ASTM C1707 Standard Test Method for Infiltration Rate of In Place Pervious Concrete to measure the infiltration rate of the pavers. A regenerative air or vacuumed sweeper should be used twice annually and after any significant site work, like landscaping, is done. However, the timing of vacuum sweeping is variable based on site conditions and biannual vacuuming may be more often than needed. Sand should never be applied to the pavers for snow removal as this will decrease the permeability of the pavers. The proposed pavers will have snowmelt capabilities, but if snow removal is necessary, mechanical snow removal should be done. If the surface of the paver system ever becomes completely clogged, remove and replacement of the first ½ to 1 inch of infill. The use of a push broom is recommended for the replacement of infill. 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design 10 7.0 Conclusion It is our conclusion that with installation of the pervious pavers and grass buffer, along with proper maintenance for these BMPs, the proposed 533 W. Hallam Street project will meet the criteria outlined in the City of Aspen’s current Urban Runoff Management Plan. 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design Appendix Appendix A Proposed Drainage Routing Schematic 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design Appendix Appendix B Water Quality Capture Volume Calculations Basin A WQCV Calculations Percent Imperviousness = ( . ./ . ) ∗ = % WQCV = . per Figure 8.13 of the COA URMP Volume = . ∗ ( . / ) = . Tree Canopy Credit = ( . .∗ . ) + ( ∗ . !) = ( " . .∗ . ) = . . Effective Impervious Area = #$% & – %( – (% & % & ∗ ) – ) * ) = . .– . .– ( ! . .∗ ) – . .= − . . Effective Imperviousness = ,- . . . .. ∗ = − % WQCV and volume were then re-calculated using the new effective imperviousness, which resulted in 0 in and -0.1 cf. Available WQCV was then calculated by adding the needed volume to the excess volume provided by the BMPs = 8.3 cf + 0.1 cf = 8.4 cf Utilized WQCV = /01 2 01 23 & 4 ∗ = , . . . ∗ = ""% Basin B WQCV Calculations Percent Imperviousness = ("! . . .) ∗ = % WQCV = . per Figure 8.13 of the COA URMP Volume = "! . ∗ 5 . 6 = . Tree Canopy Credit = ( . .∗ . ) + ( ∗ . !) = (" . .∗ . ) = . . Effective Impervious Area = #$% & – %( – (% & % & ∗ ) – ) * ) = . .– . .– ( . .∗ ) – "" . .= − . . Effective Imperviousness = ,- . "! . .. ∗ = − % WQCV and volume were then re-calculated using the new effective imperviousness, which resulted in -0.001 in and -0.2 cf. Available WQCV was then calculated by adding the needed volume to the excess volume provided by the BMPs = 10.1 cf + 0.2 cf = 10.3 cf Utilized WQCV = /01 2 01 23 & 4 ∗ = , . . . ∗ = " % 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design Appendix Basin C WQCV Calculations Percent Imperviousness = ( . . !!" . .) ∗ = ! % WQCV = . " per Figure 8.13 of the COA URMP Volume = !!" . .∗ 5 . " 6 = . Tree Canopy Credit = ( . .∗ . ) + ( ∗ . !) = ( . .∗ . ) = . . Effective Impervious Area = #$% & – %( – (% & % & ∗ ) – ) * ) = . .– . .– ( "" . .∗ ) – ! . .= − . . Effective Imperviousness = ,- . . !!" . .. ∗ = −!% WQCV and volume were then re-calculated using the new effective imperviousness, which resulted in -0.01 in and -1.2 cf. Available WQCV was then calculated by adding the needed volume to the excess volume provided by the BMPs = 12.4 cf + 1.2 cf = 13.6 cf Utilized WQCV = /01 2 01 23 & 4 ∗ = , . . . ∗ = " % Basin D WQCV Calculations Percent Imperviousness = ( ! . . . .) ∗ = ! % WQCV = . per Figure 8.13 of the COA URMP Volume = . ∗ 5 . 6 = . Tree Canopy Credit = ( . .∗ . )+ ( ∗ . ! )= ( " . .∗ . !) = " . . Effective Impervious Area = #$% & – %( – (% & % & ∗ ) – ) * ) = ! . .– " . .– ( " . .∗ ) – . .= − . . Effective Imperviousness = ,- . . . .. ∗ = − % WQCV and volume were then re-calculated using the new effective imperviousness, which resulted in -0.015 in and -2.6 cf. Available WQCV was then calculated by adding the needed volume to the excess volume provided by the BMPs = 21.4 cf + 2.6 cf = 24.0 cf 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design Appendix Utilized WQCV = /01 2 01 23 & 4 ∗ = , . . ∗ = "% 533 W. Hallam Street, Aspen, Colorado June, 2018 Drainage Report for Major Design Appendix Appendix C Peak Flow Calculations – Proposed Conditions Percent Imperviousness = ,#$% & 7 8 9 7 . ∗ = , . . . .. = ! % Maximum Watershed Length (Lo) – The maximum flow path for the property was determined to be 100ft. This is the distance from the most southern to northern part of the lot where sheet flow would occur. Watershed Slope (So) – The proposed slope for the site from north to south along the maximum flow path is 2.5%. 5-Year Runoff Coefficient (C5) – C5 was determined to be 0.36 from Figure 3.3 of the URMP. Overland Flow Time (To) – 8 = . "!( . - !):; < . = . "!( . - . ): . ! . = "." $ Channel Flow Time (Tf) – There will be no channelized flow as all runoff generated will sheet flow across the property to the curb and gutter. Time of Concentration (Tc) = 8 = 8 + 8 = "." + = "." $ 10-Year Storm 10 Year Runoff Coefficient (C10) = 0.43 – (URMP Figure 3.3) Rainfall Intensity (I) = # = . 3 ( =8 ) . ! = . ∗ . ( =".") . ! = ." /> P1 was found to be 0.77 in Table 2.2 of the URMP. Area (A) = 0.14 acres Peak Discharge (Q) = 1 = #7 = . ∗ ." ∗ . = . 100-Year Storm 10 Year Runoff Coefficient (C100) = 0.54 – (URMP Figure 3.3) Rainfall Intensity (I) = # = . 3 ( =8 ) . ! = . ∗ . ( =".") . ! = . /> P1 was found to be 1.23 in Table 2.2 of the URMP. Area (A) = 0.14 acres Peak Discharge (Q) = 1 = #7 = .! ∗ . ∗ . = . ! ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC0.00 533 W. HALLAM STREET HPC FINAL JULY 2, 2018 Exhibit K ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 09/22/17 DUNCAN RESIDENCE 533 W. HALLAM HPC0.01 ARCHITECTURALARCHITECTURALARCHITECTURALARCHITECTURAL HPC0.00 COVER HPC0.01 VICINITY MAP AND INDEX HPC0.02 HPC SUPPLIED INFORMATION HPC0.03 SURVEY HPC1.01 EXISTING SITE PLAN HPC1.02 EXISTING MAIN LEVEL HPC1.03 EXISTING UPPER LEVEL HPC1.04 EXISTING ROOF HPC1.05 EXISTING ELEVATIONS HPC1.06 EXISTING ELEVATIONS HPC1.07 EXISTING ELEVATION AREAS (DEMOLITION) HPC1.08 EXISTING ELEVATION AREAS (DEMOLITION) HPC1.09 EXISTING ROOF AREAS (DEMOLITION) HPC2.00 PROPOSED SITE PLAN HPC2.01 PROPOSED CRAWL SPACE HPC2.02 PROPOSED BASEMENT LEVEL HPC2.03 PROPOSED MAIN LEVEL HPC2.04 PROPOSED UPPER LEVEL HPC2.05 PROPOSED ROOF HPC2.06 PROPOSED ELEVATIONS HPC2.07 PROPOSED ELEVATIONS HPC2.08 COMPARISON PLAN HPC2.09 PROPOSED PERSPECTIVES HPC2.10 PROPOSED PERSPECTIVES HPC2.11 PROPOSED PERSPECTIVES HPC2.12 PROPOSED PERSPECTIVES HPC3.01 EXISTING PHOTOS HPC3.02 PROPOSED RENDERINGS HPC3.03 PROPOSED RENDERINGS HPC3.04 PROPOSED RENDERINGS HPC3.05 STREETSCAPE HPC3.06 MATERIALS HPC3.07 FENCING HPC3.08 WINDOWS HPC3.09 DOORS HPC3.10 PORCH HPC4.01 EXISTING UPPER LEVEL AREA PLAN HPC4.02 EXISTING MAIN LEVEL AREA PLAN HPC4.03 PROPOSED UPPER LEVEL AREA PLAN HPC4.04 PROPOSED MAIN LEVEL AREA PLAN HPC4.05 PROPOSED LOWER LEVEL AREA PLAN HPC4.06 PROPOSE AREA ELEVATIONS - BASEMENT LEVEL HPC4.07 PROPOSED AREA CALCULATIONS SOIL STABILIZATIONSOIL STABILIZATIONSOIL STABILIZATIONSOIL STABILIZATION Grade 1 COVER Grade 2 TEMPORARY MICROPILE AND GROUND NAIL WALLS LOCATIONS Grade 3 TEMPORARY MICROPILE AND GROUND NAIL WALLS PROFILE Grade 4 TEMPORARY MICROPILE AND GROUND NAIL WALLS GENERAL NOTES Grade 5 TEMPORARY MICROPILE AND GROUND NAIL WALLS SECTIONS Grade 6 TEMPORARY MICROPILE AND GROUND NAIL WALLS TYP SECTION & DETAILS CIVIL (STORMWATER)CIVIL (STORMWATER)CIVIL (STORMWATER)CIVIL (STORMWATER) 1 COVER G1 GENERAL NOTES G2 LEGEND AND ABBREVIATIONS C1 DEMOLITION PLAN C2 SITE PLAN C3 UTILITY PLAN C4 GRADING & DRAINAGE PLAN C5 ERROSION CONTROL PLAN C6 DETAILS (1) C7 DETAILS (2) EXTERIOR LIGHTINGEXTERIOR LIGHTINGEXTERIOR LIGHTINGEXTERIOR LIGHTING EL1.0 COVER DRAWING INDEX ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC0.02 10 ' - 0 " 10' - 0" 5' - 0 " 5' - 0" METAL FENCE METAL GATE WOOD FENCE WOOD GATE WOOD GATE PROPERTY CORNER METAL FENCE BUILDING LINE HARDSCAPE PAVERS WOOD DECK WOOD STEP WOOD DECK HARDSCAPE PAVERS WOOD GATE EN T R Y P O R C H LANDSCAPE TIMBERS PROPERTY CORNER PROPERTY CORNER PROPERTY CORNER 7 x 3 S H E D DUMPSTER ON SKIDS UTILITIES GR A V E L A L L E Y W H A L L A M S T R E E T LANDSCAPE TIMBERS 5'-0" SETBACK PROPERTY LINE 10'-0" SETBACK PROPERTY LINE 10 ' - 0 " S E T B A C K PR O P E R T Y L I N E 5' - 0 " S E T B A C K PR O P E R T Y L I N E WOOD GATE BUILDING LINE BORING POINT BORING POINT N 5TH STREET ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC1.01 SCALE 3/16" = 1'-0" EXISTING SITE PLAN EXISTING SITE PLAN PROPERTY LINE 10' SETBACK PR O P E R T Y L I N E 10 ' S E T B A C K 5' S E T B A C K PR O P E R T Y L I N E 5' SETBACK PROPERTY LINE UP UP UP UP ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC1.02 EXISTING MAIN LEVEL PLAN SCALE 1/4" = 1'-0" EXISTING MAIN LEVEL PLAN 1' 3' 6'10' PROPERTY LINE 10' SETBACK PR O P E R T Y L I N E 10 ' S E T B A C K 5' S E T B A C K PR O P E R T Y L I N E 5' SETBACK PROPERTY LINE DN UP ATTIC CRAWL SPACE ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC1.03 EXISTING UPPER LEVEL PLAN SCALE 1/4" = 1'-0" EXISTING UPPER LEVEL PLAN 1' 3' 6' 10' PROPERTY LINE 10' SETBACK PR O P E R T Y L I N E 10 ' S E T B A C K PR O P E R T Y L I N E 5' SETBACK PROPERTY LINE 12 : 12 12 : 12 7 : 12 7 : 12 12 : 1 2 12 : 1 2 12 : 1 2 12 : 1 2 12 : 1212 : 12 12 : 1212 : 12 1 : 12 2.5 : 12 8.5 : 12 6 : 1 2 1 : 1 2 12 : 1212 : 12 7 : 1 2 14 : 1 2 14 : 12 14 : 12 6 : 1 2 6 : 12 6 : 1 2 14 : 1 2 1 4 : 1 2 12 : 1212 : 12 FLAT FL A T 6 : 1 2 6 : 1 2 ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC1.04 EXISTING ROOF PLAN SCALE 1/4" = 1'-0" EXISTING ROOF PLAN 1' 3' 6' 10' ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC1.05 EXISTING ELEVATIONS SCALE 1/4" = 1'-0" EXISTING NORTH ELEVATION SCALE 1/4" = 1'-0" EXISTING EAST ELEVATION 1' 3' 6' 10' 1' 3' 6' 10' ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC1.06 EXISTING ELEVATIONS SCALE 1/4" = 1'-0" EXISTING WEST ELEVATION SCALE 1/4" = 1'-0" EXISTING SOUTH ELEVATION 1' 3' 6' 10' 1' 3' 6' 10' 64 sf 7 sf 124 sf 3 sf 76 sf 3 sf 68 sf 23 sf 10 sf 6 sf 83 sf 728 sf 34 sf 12 sf 21 sf EXISTINGEXISTINGEXISTINGEXISTING SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET WALL AREA ROOF AREA TOTAL AREA OF DEMOLITIONAREA OF DEMOLITIONAREA OF DEMOLITIONAREA OF DEMOLITION SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET WALL AREA ROOF AREA TOTAL PERCENTAGE OF DEMOLITIONPERCENTAGE OF DEMOLITIONPERCENTAGE OF DEMOLITIONPERCENTAGE OF DEMOLITION SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET WALL AREA ROOF AREA TOTAL 2,663 3,214 5,877 2,136 2,267 4,403 80.2% 70.5% 74.9% KEY EXISTING TO REMAIN TO BE DEMOLISHED ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC1.07 SCALE 1/4" = 1'-0"1 NORTH ELEVATION DEMO AREAS SCALE 1/4" = 1'-0"2 EAST ELEVATION DEMO AREAS 184 sf 667 sf 6 sf 122 sf 16 sf 14 sf 27 sf 75 sf 65 sf 182 sf 38 sf 5 sf KEY EXISTING TO REMAIN TO BE DEMOLISHED EXISTINGEXISTINGEXISTINGEXISTING SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET WALL AREA ROOF AREA TOTAL AREA OF DEMOLITIONAREA OF DEMOLITIONAREA OF DEMOLITIONAREA OF DEMOLITION SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET WALL AREA ROOF AREA TOTAL PERCENTAGE OF DEMOLITIONPERCENTAGE OF DEMOLITIONPERCENTAGE OF DEMOLITIONPERCENTAGE OF DEMOLITION SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET WALL AREA ROOF AREA TOTAL 2,663 3,214 5,877 2,136 2,267 4,403 80.2% 70.5% 74.9% ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC1.08 SCALE 1/4" = 1'-0"1 WEST ELEVATION DEMO AREAS SCALE 1/4" = 1'-0"2 SOUTH ELEVATION DEMO AREAS SCALE 1/4" = 1'-0"3 NORTH SECTION DEMO AREAS SCALE 1/4" = 1'-0"4 SOUTH SECTION DEMO AREAS 7 : 12 7 : 12 12 : 1 2 12 : 1 2 12 : 1 2 12 : 1 2 12 : 1212 : 12 12 : 1212 : 12 1 : 12 2.5 : 12 8.5 : 12 6 : 1 2 1 : 1 2 12 : 1212 : 12 7 : 1 2 14 : 1 2 14 : 12 14 : 12 6 : 1 2 6 : 12 6 : 1 2 14 : 1 2 14 : 1 2 12 : 1212 : 12 FLAT FL A T 6 : 1 2 6 : 1 2 7sf 100sf 310sf 25sf 39sf 114sf 40sf 167sf 61sf 152sf 125sf 38sf38sf 235sf 31sf 123sf 217sf 119sf135sf 136sf 120sf 118sf 112sf 124sf 117sf 30sf 89sf 78sf 78sf 34sf 12sf 63sf 15sf 4sf KEY EXISTING TO REMAIN TO BE DEMOLISHED EXISTINGEXISTINGEXISTINGEXISTING SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET WALL AREA ROOF AREA TOTAL AREA OF DEMOLITIONAREA OF DEMOLITIONAREA OF DEMOLITIONAREA OF DEMOLITION SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET WALL AREA ROOF AREA TOTAL PERCENTAGE OF DEMOLITIONPERCENTAGE OF DEMOLITIONPERCENTAGE OF DEMOLITIONPERCENTAGE OF DEMOLITION SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET WALL AREA ROOF AREA TOTAL 2,663 3,214 5,877 2,136 2,267 4,403 80.2% 70.5% 74.9% ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC1.09SCALE 1/4" = 1'-0" ROOF DEMO AREAS ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.00 PROPOSED SITE PLAN 3/16" = 1' - 0" UP MECHANICALMECHANICALMECHANICALMECHANICAL CRAWLCRAWLCRAWLCRAWL SPACESPACESPACESPACE CRAWL SPACE ACCESS ABOVE 10' SETBACK 10 ' S E T B A C K 5' S E T B A C K 5' SETBACK 10 ' S E T B A C K ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.01 SCALE 1/4" = 1'-0" PLAN PROPOSED CRAWL SPACE Copy 1 1' 3' 6' 10' UP DN LIGHT WELL LIGHT WELL CLO. LIGHT WELL LIGHT WELL BDRM #4 W.C. BATH #2 BDRM #1 BDRM #2 CLO. DRESS W.C. BATH #1 W.C. BATH #2 BDRM #3 CLO. DRESS CLO. BATH #4 ELEV. MECH. LAUNDRY MECH. PWDR FAMILY / GAME CLO. DRESS SHWRSHWR SHWR W.C. TU B BE N C H BE N C H BE N C H TV TV TV MEDIA STO. ELEV.SHWR 10' SETBACK 10 ' S E T B A C K 5' S E T B A C K PR O P E R T Y L I N E 5' SETBACK PROPERTY LINE 10 ' S E T B A C K PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E UC REF LINE OF NO CONSTURCTION ESTABLISHED BY THE PARKS DEPARTMENT 2' - 0 " 8 1 / 2 " RADIUS SET BY THE DISTANCE FROM THE COTTONWOOD TO THE LINE OF NO CONSTRUCTION. (ESTABLISHED BY THE PARKS DEPT.)LINE OF NO SURFACE OR BELOW GRADE CONSTURCTION ESTABLISHED BY THE PARKS DEPARTMENT 2' - 0"3' - 0" 4' - 0 " 4' - 0"4' - 0 " 4' - 0" 4' - 0" 4' - 0 " 4' - 0 " 4' - 0" 3' - 0 " 2' - 0 " 4" 4' - 5 1/2"1' - 10" 6 1/2" 1' - 3 1/2" FLOOR AREA CHANGE FROM INITIAL FINAL SUBMITTAL (46 SF). F.A.R. DIFFERENCE IS OFFSET BY DECREASING EXPOSED LIGHTWELL BASEMENT WALL AREA. 2' - 6 " 18' - 11" TU B BE N C H TV TV ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 08/31/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.02 PROPOSED BASEMENT LEVEL PLAN SCALE 1/4" = 1'-0" PROPOSED BASEMENT LEVEL PLAN 1' 3' 6'10' UP LIGHT WELL BELOW LIGHT WELL BELOW LIGHT WELL BELOW LIGHT WELL BELOW CHINA CABINET BAR DINING OFFICE ENTRY KITCHEN CASUAL DINING LIVING ELEV. PANTRY GARAGE BIKE MUD ROOM ENTRY ENTRY PORCH PO R C H EN T R Y P O R C H SHED PATIO AREA CL BE N C H PDR 10' SETBACK 10 ' S E T B A C K 5' S E T B A C K PR O P E R T Y L I N E 5' SETBACK 10 ' S E T B A C K PROPERTY LINE PROPERTY LINE 1 HPC3.10 ICE DWTRASH MICRO UC REF DRAWERS FRZ WINE REF WD DN LINE OF NO SURFACE OR BELOW GRADE CONSTURCTION ESTABLISHED BY THE PARKS DEPARTMENT 2' - 0 1 / 8 " 2' - 1 1 7 / 8 " 11' - 0 3/4" 2' - 1 1 7 / 8 " 2' - 0 1 / 8 " 2' - 0"3' - 0" 3 ' - 3 " 1' - 6" 1' - 1 1 1 2 7 / 1 2 8 " RADIUS SET BY THE DISTANCE FROM THE COTTONWOOD TO THE LINE OF NO CONSTRUCTION. (ESTABLISHED BY THE PARKS DEPT.) ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.03 PROPOSED MAIN LEVEL PLAN SCALE 1/4" = 1'-0" PROPOSED MAIN LEVEL PLAN 1' 3' 6'10' DN CLO. MASTER BDRM CLO. ELEV. ATTIC STORAGE & LAUNDRY MASTER BATH W.C.BE N C H SHWR SHED WASHER DRYER SHELVES VAULTED AREA OVER LIVING ROOM OPEN TO BELOW 10' SETBACK PR O P E R T Y L I N E 10 ' S E T B A C K 5' S E T B A C K PR O P E R T Y L I N E 5' SETBACK PROPERTY LINE 10 ' S E T B A C K 1 HPC3.10 LINE OF NO SURFACE OR BELOW GRADE CONSTURCTION ESTABLISHED BY THE PARKS DEPARTMENT RADIUS SET BY THE DISTANCE FROM THE COTTONWOOD TO THE LINE OF NO CONSTRUCTION. (ESTABLISHED BY THE PARKS DEPT.) ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.04 PROPOSED UPPER LEVEL PLAN SCALE 1/4" = 1'-0" PROPOSED UPPER LEVEL PLAN 1' 3' 6'10' SLOPE 12:12 SLOPE 12:12 FLAT FLAT FLAT FLAT FLAT FLAT FLAT SLOPE 12:12 SLOPE 12:12 SLOPE 12:12 SLOPE 12:12 SLOPE 12:12 SLOPE 12:12 SL O P E 12 : 1 2 SL O P E 12 : 1 2 SL O P E 12 : 1 2 SL O P E 12 : 1 2 FLAT FLAT FL A T FLAT SLOPE 12:12 SLOPE 12:12 10' SETBACK PR O P E R T Y L I N E 10 ' S E T B A C K 5' S E T B A C K PR O P E R T Y L I N E 5' SETBACK PROPERTY LINE 10 ' S E T B A C K SLOPE 12:12 FLAT SL O P E 8: 1 2 FLAT 1 HPC3.10 GUTTERS GUTTERS GUTTERS GUTTERS GUTTERS GU T T E R S GU T T E R S GUTTERS ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.05 PROPOSED ROOF PLAN SCALE 1/4" = 1'-0" PROPOSED ROOF PLAN 1' 3' 6' 10' T.O. PLY @ MAIN 99' - 9" T.O. PLY @ UPPER 110' - 1 1/2" T.O. PLY @ MAIN 99' - 9" T.O. PLY @ UPPER 110' - 1 1/2" 2 1 ' - 4 1 / 8 " FLAT ROOF HEIGHT 21 ' - 6 1 / 2 " 2 7 ' - 4 1 / 4 " RIDGE HEIGHT NARROW HORIZONTAL WOOD SIDING WOOD FASCIA WOOD FASCIA 8" HORIZONTAL WOOD SIDING METAL CLAD WINDOWS EXISTING GRADEPROPOSED GRADE ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.06 PROPOSED ELEVATIONS SCALE 1/4" = 1'-0" PROPOSED NORTH ELEVATION SCALE 1/4" = 1'-0" PROPOSED EAST ELEVATION 1' 3' 6' 10' 1' 3' 6' 10' WOOD SHINGLES WOOD FASCIA METAL CLAD WINDOWS NARROW HORIZONTAL WOOD SIDING 8" HORIZONTAL WOOD SIDING WOOD FASCIA GUTTERS 1' - 6 1/2" 12' - 2 1/2" 13' - 9" 2 1 ' - 4 1 / 8 " 2 7 ' - 2 3 / 4 " 21 ' - 3 1 / 4 " 6' - 6 " I N T E R I O R P L A T E 1 8 ' - 1 1 " METAL CLAD WINDOWS WOOD SHINGLES WOOD FASCIA NARROW HORIZONTAL WOOD SIDING WOOD FASCIA WOOD COLUMNS GUTTERS3D ELEVATION VIEW @ CONNECTOR EXISTING GRADEPROPOSED GRADE ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.07 PROPOSED ELEVATIONS SCALE 1/4" = 1'-0" PROPOSED SOUTH ELEVATION SCALE 1/4" = 1'-0" PROPOSED WEST ELEVATION 1' 3' 6' 10' 1' 3' 6' 10' FLAT ROOF HEIGHT RIDGE HEIGHTHEIGHT MESURED FROM 1/3 POINT LIGHT WELL BELOW LIGHT WELL BELOW LIGHT WELL BELOW LIGHT WELL BELOW 8' - 4 1/2" HISTORIC ASSET IS RELOCATED 8'-4 1/2" FORWARD (NORTH) ON- SITE. PROPOSED STRUCTURE EXISTING STRUCTURE HISTORIC STRUCTURE TO BE PRESERVED PDR CL BAR CHINA CABINET DINING OFFICE EN T R Y P O R C H EN T R Y P O R C H ENTRY CASUAL DINING KITCHEN LIVING ELEVATOR PANTRY ENTRYSTORAGE DN UP SHED BIKE ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.08 COMPARISON PLAN ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.09 NORTHEAST ELEVATION A NORTHEAST PHOTO A NORTHEAST ELEVATION B SOUTHEAST PHOTO B PROPOSED PERSPECTIVES ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.10 NORTH ELEVATION C NORTH ELEVATION PHOTO C NORTH ELEVATION D NORTH ELEVATION PHOTO D PROPOSED PERSPECTIVES ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.11 NORTH ELEVATION E NORTH ELEVATION F NORTH WEST ELEVATION G WEST ELEVATION H PROPOSED PERSPECTIVES ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC2.12 WEST ELEVATION I SOUTHWEST ELEVATION J SOUTHWEST ELEVATION K SOUTH EAST ELEVATION L PROPOSED PERSPECTIVES ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC3.01 EXISTING HOUSE HALLAM ST.5TH ST. BACK OF HISTORIC ASSETALLEY ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC3.02 PROPOSED RENDERING ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC3.03 PROPOSED RENDERING ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC3.04 PROPOSED RENDERING ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC3.05 HALLAM STREET VIEW 5TH STREET VIEW HORIZ. CHANNEL LAP WOOD SIDING INTERIOR FINISH REF. FINISH SHCHED. WEATHER RESISTIVE BARRIER 11/32"1/4" 1 1/2" DRAINAGE MAT INTERIOREXTERIOR SPRAYED FOAM INSUL. R-20 MIN. WOOD FRAMING REF. STRUCT. DWGS. 5/8" GYPSUM WALL BRD PER PLAN 5/8" INSULATED SHEATHING PANEL R-5 MIN.7 5 / 8 " 3/ 4 " 8 3 / 8 " 1/ 2 " T JI11 7 /8 " CEDAR SHINGLES FSR PRESSURE TREATED, CLASS B 5/8" SHEATHING, REF. STRUCTURAL SPRAY FOAM INSULATION (R-49 MIN) TJI RAFTER, REF. STRUCTURAL 5/8" GYPSUM WALL BOARD (REF. INT. FIN. SCHED.) SELF ADHERED WATERPROOF MEMBRANE MINERAL SURFACED CAP SHEET, CLASS A E X P O S U R E 5" CEDAR BREATHER, CLASS A CLASS A ROOF ASSEMBLY COMPOSITE METAL PANEL PER MFR. WEATHER RESISTIVE BARRIER INTERIOR COMPOSITE METAL PANEL HANGERS PER MFR EXTERIOR SPRAYED FOAM INSUL. R-20 MIN. WOOD FRAMING REF- STRUCT. DWGS. INTERIOR FINISH REF. FINISH SCHEDULE PER PLAN1 5/8"1 1/2" 3 1/8" INSULATED SHEATHING PANEL R-5 MIN. PA N E L M O D U L E 1/ 2 " PA N E L M O D U L E ACCENT STRIP PANEL FASTENER PANEL ATTACHMENT CLIP HORIZ. PAINTED WOOD SIDING INTERIOR FINISH REF. FINISH SHCHED. WEATHER RESISTIVE BARRIER 1 3/4" 1/4" 1 1/2" DRAINAGE MAT INTERIOREXTERIOR SPRAYED FOAM INSUL. R-20 MIN. WOOD FRAMING REF. STRUCT. DWGS. 5/8" GYPSUM WALL BOARD PER PLAN 5/8" INSULATED SHEATHING PANEL R-5 MIN. 2 " T O 3 " 1" 1" 3/4" HE-PEX TUBING, 10" O.C. WWF OR REBAR 2' X 2' MAX GRID SPACING CONCRETE PAVERS WITH GRASS JOINTS 2" MAX SAND BEDDING 3" PERFORATED INSULATION*, R-15 6" ASTM NO. 57 STONE OPEN-GRADED BASE *INSULATION SHALL BE PERFORATED 6" O.C. WITH 1" DIA. HOLES 6" 3" 2" ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC3.06 MATERIALS CLAPBOARD TO MATCH EXISTING WOOD SHINGLE ROOF NARROW HORIZONTAL WOOD SIDING METAL PANEL CLADDING CONCRETE PAVING STONES WITH GRASS CHANNEL LAP WOOD SIDING APPROXIMATE COLOR GUTTERS PER ROOF PLAN 3' - 0 " 5 1/2"5 1/2" 5' - 6 " PAINTED WOOD ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC3.07 FRONT YARD FENCE PRIVACY FENCE @ SHARED PROPERTY LINE FENCING 229 W. HALLAM ST. 320 W. HALLAM ST.333 W. BLEEKER ST. 735 W. BLEEKER ST. 631 W. BLEEKER ST. 212 LAKE AVE. PAINTED WOODFENCE POSTS NOT TO ENCROACH ON ROOT STRUCTURES FRONT YARD FENCE PRIVACY FENCE EXISTING EXAMPLESEXISTING EXAMPLESEXISTING EXAMPLESEXISTING EXAMPLES 3 1 / 2 " 3 3 / 8 " 5' - 9 1 / 2 " 2 1 / 8 " 1 3 / 4 " 2' - 7 3 / 4 " 1 1 / 8 " 2' - 7 1 / 2 " 3 3 / 8 " 3' - 6 3/4" 2 7/8"3' - 1"2 7/8" 5/8"4 3/8"1 5/8"1' - 11 3/4"1 5/8"4 3/8"5/8" 2' - 11 3/4" 3' - 1" EXISTING WINDOW FRONT ELEVATION EXISTING WINDOW VERTICAL SECTION EXISTING WINDOW PLAN SECTION UPPER LOWER A A A A B C A AA A A B B A A A EXISTING WINDOW TO REMAIN B HISTORIC WINDOW REPLICA C EXISTING WINDOW TO BE RELOCATED D NON HISTORIC GABLE WINDOW TO BE REPLACED D E ABOVE ABOVE E HISTORIC GABLE WINDOW TO REMAIN ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC3.08 (WINDOW D) SOUTH SIDE NON HISTORIC GABLE WINDOW TO BE REPLACED. NEW WINDOW TO MATCH NORTH GABLE WINDOW. THIS IS CURRENTLY A MODERN PELLA DOUBLE HUNG WINDOW. NORTH SIDE EXISTING GABLE WINDOW TO REMAIN. THERE ARE ONLY THREE EXISTING GABLE WINDOW THIS SIZE TO REMAIN. GRABILL WINDOWS AND DOORS WILL BE MANUFACTURING THREE REPLICAS OF THIS WINDOW BASED ON SHOP DRAWINGS PRODUCED BY HANSEN CONSTRUCTION. (WINDOW C) EAST SIDE EXISTING WINDOW TO BE PRESERVED AND RELOCATED. (WINDOW A AND B) 3 7/8"10 1/8"2"10 1/8"3 7/8" 1 1/4"1 1/4" 9 1 / 4 " 1' - 5 " 8 1 / 4 " 3' - 4 " 4 1 / 2 " 1 1 / 4 " 1 1 / 4 " 1 1 / 4 " 6' - 7 " 2' - 6" 3 7/8"8 5/8"5"8 5/8"3 7/8" 1 1/4"1 1/4"1 1/4"1 1/4"1 1/4" 6' - 7 " EXTERIORINTERIOR 6' - 7 " 4 1 / 2 " 3' - 4 " 8 1 / 4 " 1' - 5 " 9 1 / 4 " 3 7/8"10 1/8"2"10 1/8"3 7/8" 2' - 6" 3 7/8"8 5/8"5"8 5/8"3 7/8"1 1/4" 6' - 7 " EXTERIORINTERIOR 2' - 3 1/2" 3 7/8"7 3/8"5"7 3/8"3 7/8" 3 7 / 8 " 3' - 2 1 / 2 " 8 7 / 8 " 1' - 4 1 / 8 " 5 7 / 8 " 6' - 1 1 / 4 " 7' - 0 " 3' - 0" 3' - 0" 1 3/4" 7' - 0 " EXTERIORINTERIOR 5"11 1/2"3"11 1/2"5" 9" 2' - 2 " 3' - 7 " 6" 3' - 0" B C A A EXISTING HISTORIC DOOR TO BE RELOCATED B EXISTING HISTORIC DOOR REPLICA C NEW ENTRY DOOR ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC3.09SCALE 1" = 1'-0"1 EXISTING HISTORIC ENTRY DOOR - EXTERIOR SCALE 1" = 1'-0"2 EXISTING HISTORIC ENTRY DOOR - INTERIOR SCALE 1" = 1'-0"3 EXISTING SHED DOOR SCALE 1" = 1'-0"4 PROPOSED ENTRY DOOR - EXTERIOR HISTORIC DOOR LOCATED ON THE SHED HISTORIC ENTRY DOOR LOCATED ON THE 5TH STREET SIDE OF THE EXISTING HOUSE DOOR C DOOR A AND B DOOR A AND B CEDAR SHINGLE ROOF BOTTOM OF HISTORIC STRUCTURE HISTORIC PLATE GUTTER SLIGHTLY SLOPING SURFACE DIMENSIONALLY ACCURATE REPLICA OF THE HISTORIC SIDING GUTTER MATERIALS BELOW THIS POINT WILL BE REPLICATED FROM EXISTING PORCH FASCIA REPLICATED FROM EXISTING ROOF EXISTING CONDITIONS FULLY ENCLOSEDCIRCA 1980'S CIRCA 1960'S ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC3.10 PORCH SCALE 1 1/2" = 1'-0"1 PROPOSED PORCH FLAT ROOF SECTION DN UP 208 sf 366 sf 41 s f < 5 ' -6" s f 58sf <30" Vertical 58sf <30" VerticalOPEN TO BELOW CHIMNEY EXISTINGEXISTINGEXISTINGEXISTING SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET FLOOR AREA GARAGE (<250 EXEMPT) TOTAL UPPER LEVELUPPER LEVELUPPER LEVELUPPER LEVEL FLOOR AREA ATTIC <30" (EXEMPT) TOTAL TOTALTOTALTOTALTOTAL FAR 1,853sf 232sf 1,853sf 574sf 116sf 574sf 2,427sf PORCH (EXEMPT)50sf <5'-6" (EXEMPT)41sf ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC4.01 SCALE 1/4" = 1'-0" EXISTING UPPER LEVEL AREA CALCULATIONS EXISTING UPPER LEVEL AREA PLAN 1,640 sf 232 sf (GARAGE) <250 = 0 207 sf 31 sf 50 sf EXISTINGEXISTINGEXISTINGEXISTING SQUARE FEET SQUARE FEET SQUARE FEET SQUARE FEET FLOOR AREA GARAGE (<250 EXEMPT) TOTAL UPPER LEVELUPPER LEVELUPPER LEVELUPPER LEVEL FLOOR AREA ATTIC <30" (EXEMPT) TOTAL TOTALTOTALTOTALTOTAL FAR 1,853sf 232sf 1,853sf 574sf 116sf 574sf 2,427sf PORCH (EXEMPT)50sf <5'-6" (EXEMPT)41sf ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC4.02 SCALE 1/4" = 1'-0" EXISTING MAIN LEVEL AREA CALCULATIONS EXISTING MAIN LEVEL AREA PLAN CLO.CLO.CLO.CLO. MASTERMASTERMASTERMASTER BDRMBDRMBDRMBDRM CLO.CLO.CLO.CLO. ELEV.ELEV.ELEV.ELEV. ATTICATTICATTICATTIC STORAGESTORAGESTORAGESTORAGE &&&& LAUNDRYLAUNDRYLAUNDRYLAUNDRY MASTERMASTERMASTERMASTER BATHBATHBATHBATH W.C.W.C.W.C.W.C. LEVEL 2 971 sf OPEN TO BELOW SHWRSHWRSHWRSHWR LI N E W H E R E C E I L I N G I S 30 " A B O V E T H E F L O O R AREA WHERE CEILING IS LESS THAN 30" ABOVE THE FLOOR ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC4.03 SCALE 1/4" = 1'-0" PROPOSED UPPER LEVEL AREA CALCULATIONS PROPOSED UPPER LEVEL AREA PLAN ELEV.ELEV.ELEV.ELEV. GARAGEGARAGEGARAGEGARAGE MUDMUDMUDMUD ROOMROOMROOMROOM ENTRYENTRYENTRYENTRY PANTRYPANTRYPANTRYPANTRY OFFICEOFFICEOFFICEOFFICE ENTRYENTRYENTRYENTRYENTRYENTRYENTRYENTRY HALLHALLHALLHALL KITCHENKITCHENKITCHENKITCHEN CASUALCASUALCASUALCASUAL DININGDININGDININGDINING DININGDININGDININGDINING STAIRSSTAIRSSTAIRSSTAIRS BIKESBIKESBIKESBIKES GARAGE AREA = 550 sf LEVEL 1 AREA = 2139 sf 92 sf 50 sf 51 sf LIGHT LIGHT LIGHT LIGHT WELL WELL WELL WELL BELOWBELOWBELOWBELOW LIGHT LIGHT LIGHT LIGHT WELL WELL WELL WELL BELOWBELOWBELOWBELOW LIGHT LIGHT LIGHT LIGHT WELL WELL WELL WELL BELOWBELOWBELOWBELOW LIGHT LIGHT LIGHT LIGHT WELL WELL WELL WELL BELOWBELOWBELOWBELOW 46 sf BAR CHINA CUPBOARD ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC4.04 SCALE 1/4" = 1'-0" PROPOSED MAIN LEVEL AREA CALCULATIONS PROPOSED MAIN LEVEL AREA PLAN LIGHT WELL LIGHT WELL CLO. LIGHT WELL LIGHT WELL BDRM #4 W.C. BATH #2 BDRM #1 BDRM #2 CLO. DRESS W.C. BATH #1 W.C. BATH #2 BDRM #3 CLO. DRESS ELEV. CLO. BATH #4 ELEV. MECH. LAUNDRY MECH. PWDR FAMILY / GAME CLO. DRESS SHWRSHWR SHWR W.C. BASEMENT LEVEL AREA = 3578 sf 63' - 9 1/2"14' - 1"4' - 0" 6' - 6 9 5 / 1 2 8 " 11 ' - 9 6 5 / 1 2 8 " 12 ' - 0 1 / 4 " 11 ' - 7 " 4' - 0" 4' - 10"55' - 7"4' - 0"22' - 3 1/2" 4' - 2 " 35 ' - 3 1 / 2 " 2' - 6 " 41 ' - 1 1 1 / 2 " 1 2 3 4 5 6 7 8 9 10 1112 13 1415 16 17 18 19 ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC4.05 SCALE 1/4" = 1'-0" PROPOSED LOWER LEVEL AREA CALCULATIONS PROPOSED BASEMENT AREA PLAN -ABOVE GRADE (EXPOSED) -BELOW GRADE HATCH AREA LEGEND - (ELEVATIONS) 45 sf 5 sf 12 ' - 4 3 / 8 " 4' - 0" T.O. PLY @ BASEMENT 86' - 4" 18 sf 2 sf 1' - 8" T.O. PLY @ BASEMENT 86' - 4" 772 sf 12 ' - 4 3 / 8 " 62' - 5 1/2" T.O. PLY @ BASEMENT 86' - 4" 12 ' - 4 3 / 8 " 18 sf 2 sf 1' - 8" 12 ' - 4 3 / 8 " 4' - 0" 45 sf 5 sf T.O. PLY @ BASEMENT 86' - 4" 12 ' - 4 3 / 8 " 18 sf 2 sf 1' - 8" T.O. PLY @ BASEMENT 86' - 4" 94 sf 12 ' - 4 3 / 8 " 7' - 7" T.O. PLY @ BASEMENT 86' - 4" 5' - 8 7/8" 71 sf 12 ' - 4 3 / 8 " T.O. PLY @ BASEMENT 86' - 4" 12 ' - 4 3 / 8 " 45 sf 3' - 7 1/2" T.O. PLY @ BASEMENT 86' - 4" 417 sf 12 ' - 4 3 / 8 " 33' - 8 3/4" 250 sf 20' - 3" 12 ' - 4 3 / 8 " T.O. PLY @ BASEMENT 86' - 4" 4' - 0" 12 ' - 4 3 / 8 " 45 sf 5 sf T.O. PLY @ BASEMENT 86' - 4" 4' - 0" 12 ' - 4 3 / 8 " 45 sf 5 sf T.O. PLY @ BASEMENT 86' - 4" 12 ' - 4 3 / 8 " 45 sf 5 sf 4' - 0" T.O. PLY @ BASEMENT 86' - 4" 673 sf 54' - 3" 12 ' - 4 3 / 8 " 35 sf 35 sf 12 ' - 4 3 / 8 " 3' - 4"2' - 6" T.O. PLY @ BASEMENT 86' - 4" 4' - 0" 45 sf 5 sf 12 ' - 4 3 / 8 " T.O. PLY @ BASEMENT 86' - 4" 33' - 11 1/2" 12 ' - 4 3 / 8 " 420 sf T.O. PLY @ BASEMENT 86' - 4" 12 ' - 4 3 / 8 " 1' - 8" 21 sf ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC4.06 SCALE 1/4" = 1'-0" 1 SCALE 1/4" = 1'-0" 2 SCALE 1/4" = 1'-0" 3 SCALE 1/4" = 1'-0" 4 SCALE 1/4" = 1'-0" 5 SCALE 1/4" = 1'-0" 6 SCALE 1/4" = 1'-0" 7 SCALE 1/4" = 1'-0" 8 SCALE 1/4" = 1'-0" 9 SCALE 1/4" = 1'-0" 10 SCALE 1/4" = 1'-0" 11 SCALE 1/4" = 1'-0" 12 SCALE 1/4" = 1'-0" 13 SCALE 1/4" = 1'-0" 14 SCALE 1/4" = 1'-0" 15 SCALE 1/4" = 1'-0" 16 SCALE 1/4" = 1'-0" 17 SCALE 1/4" = 1'-0" 18 PROPOSED BASEMENT AREA ELEVATIONS SCALE 1/4" = 1'-0" 19 BASEMENT LEVEL FLOOR AREA CALCULATIONS BASEMENT LEVEL TOTAL = 455 sf LEVEL 1 = 2,139 sf LEVEL 2 LEVEL 1 TOTAL = 2,689 sf 46 sf 92 sf 50 sf +51 sf (EXCLUDED) = 239 sf LEVEL 1 AREA GARAGE AREA LEVEL 2 TOTAL = 971 sf 3,240 sf 500 sf TOTAL FAR ALLOWABLE LOT FAR ALLOWABLE HPC FAR INCENTIVE (500 POSSIBLE) SUMMARY 455 sf 2,689 sf + 971 sf BUILDING TOTAL = 4,115 sf BASEMENT LEVEL 1 LEVEL 2 BUILDING TOTAL = 3,740 sf GARAGE EXEMPTION 375 sf DECK AREA (EXCLUDED) = 550 sf BUILDING TOTAL -GARAGE EXEMPTION 4,115 sf -375 sf TOTAL AREA = 3,740 sf -ABOVE GRADE (EXPOSED) -BELOW GRADE HATCH AREA LEGEND - (ELEVATIONS) -LIGHT WELL -DECKS HATCH AREA LEGEND - (PLAN) -GARAGE -LIVABLE ABOVE GRADE = 359 sf BELOW GRADE =2,834 sf ABOVE GRADE (359 sf) / BELOW GRADE (2,834 sf) =12.7% 12.7 % X INCLUDED BASEMENT AREA (3,578 sf) = 455 sf TOTAL INCLUDED BASEMENT LEVEL AREA = 455 sf ELEVATION ABOVE BELOW 1 45 5 2 3 4 5 6 7 8 9 10 11 12 13 14 18 16 TOTALS 359 sf 2,834 sf ELEVATION AREAS (sf.) BASEMENT LEVEL FLOOR AREA CALCULATIONS 17 18 2 772 18 2 45 5 18 2 94 71 45 417 250 45 5 45 5 45 5 420 15 673 35 35 45 5 19 21 ( T ) 9 7 0 / 9 2 5 4 7 5 5 ( F ) 9 7 0 / 9 2 0 2 9 5 0 6 0 5 E A S T M A I N S T R E E T A S P E N, C O L O R A D O 8 1 6 1 1 07/02/18 DUNCAN RESIDENCE 533 W. HALLAM HPC4.07 PROPOSED AREA CALCULATIONS Duncan Residence 533 West Hallam Street Aspen, Colorado Temporary Excavation Shoring Micropile and Ground Nail Walls* Grade-1. Temporary Micropile and Ground Nail Walls - Cover Grade-2. Temporary Micropile and Ground Nail Walls - Locations Grade-3. Temporary Micropile and Ground Nail Walls - Profile Grade-4. Temporary Micropile and Ground Nail Walls - General Notes Grade-5. Temporary Micropile and Ground Nail Walls - Sections Grade-6. Temporary Micropile and Ground Nail Walls - Typical Sections and Details * These plans and specifications are designed to provide temporary excavation support with a finite design life during construction operations. Long-term earth pressure loads shall be included in the structural design. Temporary Micropile and Ground Nail Walls Cover September 4, 2018 Duncan Residence 533 West Hallam Street 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 18-029G-D1 Grade-1 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Set Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For:Seal: PROPERTY LINE RADIUS SET BY THE DISTANCE FROM THE COTTONWOOD TO THE LINE OF NO CONSTRUCTION. (ESTABLISHED BY THE PARKS DEPT.)LINE OF NO SURFACE OR BELOW GRADE CONSTURCTION ESTABLISHED BY THE PARKS DEPARTMENT 10' SETBACK 2' - 0"3' - 0" LINE OF NO CONSTURCTION ESTABLISHED BY THE PARKS DEPARTMENT LIGHT WELL 4' - 0"BDRM #1 CLO. W.C.SHWR SHWR W.C. CLO. LIGHT WELL 4' - 0" DRESS BATH #1 BATH #2 DRESS BDRM #3 6 1/2" 1' - 3 1/2" TV SHWR TV W.C.CLO.UP BATH #2 FAMILY / GAME DRESS PWDR STO. TV BDRM #4 BDRM #2 DN ELEV. UC REF ELEV. MECH. LAUNDRY MECH. BATH #4 CLO. MEDIA TV SHWR TVW.C. CLO. 4' - 5 1/2"1' - 10" LIGHT WELL LIGHT WELL 4' - 0"4' - 0" 5' SETBACK PROPERTY LINE PR O P E R T Y L I N E 4' - 0 " 4' - 0 " TU B 5' S E T B A C K 3' - 0 " 2' - 0 " 4" 10 ' S E T B A C K BE N C H BE N C H BE N C H TU B BE N C H 4' - 0 " 4' - 0 " 2' - 0 " 8 1 / 2 " 10 ' S E T B A C K PR O P E R T Y L I N E PR O P E R T Y L I N E Begin/End Wall Micropile Turn Line 3 Ground Nail Turn Line 4 Change Ground Nail to Micropile Turn Line 5 Micropile Temporary Ground Nail Wall Temporary Micropile Cap/Wall 0+ 3 0 Gr a d e - 5 1+10 Grade-5 1+ 9 0 Gr a d e - 5 2+50 Grade-5 0+ 2 0 0+ 4 0 0+ 6 0 0+ 8 0 1+00 1+20 1+ 4 0 1+ 6 0 1+ 8 0 2+ 0 0 2+ 2 0 2+40 2+60 Ground Nails below Grade Ground Nails below Grade Turn Lines 1 and 2 Change Micropile to Ground Nail Temporary Micropile and Ground Nail Walls Locations September 4, 2018 Duncan Residence 533 West Hallam Street 18-029G-D1 Grade-2 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Sheet Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For: Notes: 1. Base plan by Poss Architecture dated 08-31-2018. 2. For utility installation, trench to back of micropile or ground nail wall. For micropile wall, hand dig between micropiles and extend utilities through wall. For ground nail wall, saw or hammer through shotcrete facing and extend utilities through wall.SCALE: 1" = 5' 5 0 2.5 5 NSeal: 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 7920 7930 7910 7900 7890 El e v a t i o n ( f e e t ) 0+ 0 0 . 0 B e g i n W a l l Mi c r o p i l e EG = 7 9 1 5 . 0 TO W = 7 9 1 5 . 0 BO E = 7 9 0 1 . 0 0+ 5 0 7940 7920 7930 7910 7900 7890 7940 NAIL LENGTH SCHEDULE Micropile Wall Cap Top of Ground Nail Wall (TOW) 1+ 0 0 Bottom of Excavation (BOE) El e v a t i o n ( f e e t ) Temporary Slope at 1H:1V 0+ 8 9 . 7 T u r n L i n e 3 Gr o u n d N a i l EG = 7 9 1 3 . 0 TO W = 7 9 1 3 . 0 BO E = 7 9 0 1 . 0 10 feet Existing Grade Strip Drains Ground Nail 1+ 5 0 2+ 0 0 2+ 5 0 1+ 3 5 . 9 T u r n L i n e 4 Ch a n g e G r o u n d N a i l t o M i c r o p i l e EG = 7 9 1 3 . 0 TO W = 7 9 1 3 . 0 BO E = 7 9 0 1 . 0 2+ 2 3 . 3 T u r n L i n e 5 Mi c r o p i l e EG = 7 9 1 5 . 0 St e p T O W = 7 9 1 5 . 0 t o 7 9 1 4 . 5 BO E = 7 9 0 1 . 0 2+ 7 1 . 5 E n d W a l l Mi c r o p i l e EG = 7 9 1 5 . 0 TO W = 7 9 1 4 . 5 BO E = 7 9 0 1 . 0 Existing Grade Mechanical/Crawlspace BOE at El. 7894.0 12 feet 0+ 2 3 . 6 T u r n L i n e 1 Ch a n g e M i c r o p i l e t o G r o u n d N a i l EG = 7 9 1 4 . 5 TO W = 7 9 1 4 . 5 BO E = 7 9 0 1 . 0 0+ 2 5 . 6 T u r n L i n e 2 Gr o u n d N a i l EG = 7 9 1 4 . 5 TO W = 7 9 1 4 . 5 BO E = 7 9 0 1 . 0 Temporary Micropile and Ground Nail Walls Profile September 4, 2018 Duncan Residence 533 West Hallam Street 18-029G-D1 Grade-3 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Sheet Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For:Seal: 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 SCALE: HORIZONTAL 1" = 10' VERTICAL 1" = 10' ABBREVIATIONS: EG - Existing Grade PG - Proposed Grade TOW - Top of Wall BOE - Bottom of Excavation 1.0 Temporary Micropile Wall Materials 1.1 Micropile bars - Williams B7X1-51 Injection Bars or equivalent fy=85,000 psi 1.2 Grout - Grout may be neat-cement or with sand, with Type II cement in accordance with ASTM C150. Water-cement ratio should be between 0.4 and 0.6. f'c=3,000 psi (28-day strength) 1.3 End hardware - Nuts shall be in accordance with manufacturer's recommendations. Bearing plate shall be in accordance with ASTM A36, Grade 36. 1.4 Concrete - Concrete mix shall consist of Type II cement in accordance with ASTM C150, potable water and normal weight aggregate in accordance with ASTM C33. Air entrainment is not required. Admixtures, if used, should be non-corrosive to steel. f'c=3,000 psi (28-day strength) 1.5 Cap reinforcement shall be in accordance with ASTM A615. fy=60,000 psi 2.0 Micropile Wall Construction Sequence 2.1 Install micropiles at the locations and to the lengths shown on the plans. Micropile injection bars shall be installed per manufacturers recommendations. Micropile locations may vary by up to 3". 2.2 Install end hardware and reinforcing bars as shown on the drawings. 2.3 Pour concrete cap to the minimum thickness shown on the drawings and to attain the minimum coverages specified herein. Cold weather protection measures may be necessary. 2.4 After concrete and grout has attained 80% of specified strength, complete excavation to full depth of wall not to exceed maximum wall heights as shown on the drawings. Excavation shall extend to grout/micropile columns (cap may be undermined). Soil should not be left between excavation face and grout/micropile columns. 3.0 Temporary Micropile Wall Design Parameters 3.1 The micropile shoring was designed in general accordance with procedures contained in the FHWA "Micropile Design and Construction Reference Manual", Publication No. FHWA NHI-05-039, December 2005. 3.2 The following strength parameters were assumed for the subsoils based on our experience in the area with similar projects. The following values were assumed for soil design parameters: f g (deg) (psf) (pcf) Sand and Gravel 36 100 130 An experienced geotechnical engineer should verify the above design parameters during construction. 3.3 Global Factor of Safety = 1.3 min. (temporary) 3.4 Surcharge Loading - The excavation shoring systems are designed to accommodate normal construction surcharge of material and light trucks, not heavy loads such as cranes (wheels or outriggers), concrete pumpers (wheels or outriggers) or large stockpiles that apply a ground pressure of 1,000 psf or greater. Heavy loads shall not be placed within 8 feet of micropile cap unless approved by RJ Engineering. 3.5 No groundwater table was assumed. If groundwater is encountered during excavation, the excavation shall not continue and the site shall be dewatered to below the base of planned excavation elevation prior to completion of the excavation. 3.6 The micropile walls lateral deflection may be up to about 0.003' per foot of excavation depth at the ROW, and no adverse deflection of the ground surface at the private property line based on anticipated subsurface conditions. 4.0 Special Provisions 4.1 Wall geometry used in design was based on plans provided by client. 4.2 This design is valid only for B&Y Drilling, Inc. at the subject site. B&Y Drilling shall construct all shoring systems shown herein. 4.3 Excavation shall extend to micropile columns. During the excavation process, material should not be left between the excavation face and the grout/micropile column. 4.4 The micropile wall designs are valid only for dry surface and subsurface conditions. If surface water or groundwater is encountered during excavation or installation, RJ Engineering should be notified immediately and the wall may be redesigned at the discretion of RJ Engineering. Surface and subsurface drainage from adjacent properties should not be discharged at the top or through the micropile wall. Saturated soils may result in materials piping out from between micropiles resulting in failure and/or excessive wall movements. 4.5 The design life on this micropile wall is 12 weeks. Design life is defined by the beginning of excavation to backfill completion of the foundation wall. If the duration of the project exceeds the 12 week duration, RJ Engineering shall be contacted to evaluate the performance of the system and determine if the design life can be extended. 4.6 RJ Engineering is not responsible for maintaining slope stability above and below the micropile wall during construction. 4.7 RJ Engineering is not aware of any utility conflicts. The contractors are responsible for field locating all nearby utilities. Conflicting utilities may require micropile wall redesign at RJ Engineerings' discretion. 4.8 RJ Engineering is not responsible for quality control, quality assurance, changed conditions or problems resulting from improper construction techniques. 4.9 RJ Engineering is not responsible for construction site safety. 4.10 RJ Engineering is not responsible for wall layout. General contractor or representative of the general contractor is responsible for micropile wall layout. 4.11 Observation of micropile wall installation should be performed by a qualified engineer. Inspection and/or monitoring of the micropile wall after completion of excavation should be performed. The frequency and duration of the observation and monitoring shall be determined by the qualified engineer. The qualified engineer shall have experience with design and installation of micropile wall systems using injection bars. Observations shall be made at least on a weekly basis during installation and during the service life of the system. 5.0 Temporary Ground Nail Wall Materials 5.1 Ground Nails - Grade 75 threadbar or equivalent in accordance with ASTM A615 or Williams injection bar. fy=75,000 psi 5.2 Grout - Grout may be neat-cement or with sand, with Type II cement in accordance with ASTM C150. Water-cement ratio should be between 0.4 and 0.6. f'c=1,500 psi minimum 3 day f'c=3,000 psi minimum 28 day 5.3 End hardware - Nuts and washers shall be in accordance with ground nail manufacturer's recommendations. Bearing plate shall be in accordance with ASTM A36, Grade 36. 5.4 Shotcrete - Shotcrete mix shall consist of Type II cement in accordance with ASTM C150, potable water and normal weight aggregate in accordance with ASTM C33. Admixtures, if used, should be non-corrosive to steel. f'c=4,000 psi (28-day strength) 5.5 Welded wire mesh shall be in accordance with ASTM A185. 5.6 Walers and vertical bearing bars shall be in accordance with ASTM A615. fy=60,000 psi 5.7 Strip drains consist of 12" wide dimpled cores wrapped in geotextile. The compressive strength of the core should be at least 20 psi when tested in accordance with ASTM D1621, and it's in-plane flow capacity should be at least 10 gpm/ft when tested in accordance with ASTM D4716 5.8 Centralizers should be plastic that will provide free passage of grout and attached to the nails in accordance with the manufacturer's recommendations. Centralizers not required for injection bars. 6.0 Temporary Ground Nail Wall Construction Sequence 6.1 Excavate one lift to a maximum depth of five feet. 6.2 Install ground nails at the locations and to the lengths shown on the plans. Ground nail location may vary by up to 6". Tremie the grout from the bottom of the hole up. 6.3 Install strip drains, welded wire mesh, walers and bearing bars as shown on the drawings. Use chairs to hold the welded wire mesh away from the soil as necessary. 6.4 Install shotcrete to the minimum thickness shown on the drawings and to attain the minimum coverages specified herein. Give special attention to filling the void in the borehole above the grout line. Cold weather protection measures may be necessary. 6.5 Install the ground nail end hardware after the minimum inside coverage specified herein has been attained. While the shotcrete is still wet, embed the plate into the shotcrete surface until there is no void behind the plate. Handtighten the nut. 6.6 Once the grout and shotcrete have attained 80% of their specific strengths, repeat 2.1-2.5 to the bottom of the wall. 6.7 At the bottom lift, complete strip drains to daylight as shown on the drawings. 7.0 Temporary Ground Nail Wall Design Parameters 7.1 The ground nail wall has been designed in general accordance with procedures contained in the FWHA "Manual for Design and Construction Monitoring of Soil Nail Walls", Report No. FHWA-SA-96-069R. 7.2 The following strength parameters were assumed for the subsoils based on our experience in the area with similar projects. The following values were assumed for soil design parameters: f c g Qult (deg) (psf) (pcf) (psi) Sand and Gravel 36 100 130 24 An experienced geotechnical engineer should verify the above design parameters during construction. 7.3 Groundwater level was assumed to be below the base of the wall. 7.4 Factors of safety Global - FS > 1.3 (temporary) Nail Tension Strength Factor - QN = 0.55 Nail Pullout Resistance Factor - QQ = 0.50 Nail Head Strength Factor - QF = 0.67 7.5 Surcharge Loading - The ground nail wall is designed to accommodate normal construction surcharge of material and light trucks, not heavy loads such as cranes (wheels or outriggers), concrete pumpers (wheels or outriggers) or large stockpiles that apply a ground pressure of 1,000 psf or greater. Heavy loads shall not be placed within 6 feet of face of ground nail wall unless approved by RJ Engineering. 7.6 Corrosivity was assumed to be low. 7.7 The maximum design life of the temporary shoring is 12 months. 8.0 Special Notes 8.1 Wall geometry used in design was based on information from plans provided by client. 8.2 This design is valid only for B&Y Drilling, Inc. at the subject site. B&Y Drilling shall construct all shoring systems shown herein. 8.3 RJ Engineering is not responsible for maintaining slope stability above and below the ground nail wall during construction. 8.4 RJ Engineering is not aware of any utility conflicts. The contractors are responsible for field locating all nearby utilities. Conflicting utilities may require ground nail wall redesign at RJ Engineerings' discretion. 8.5 RJ Engineering is not responsible for quality control, quality assurance, changed conditions or problems resulting from improper construction techniques, and construction site safety. 8.6 RJ Engineering is not responsible for wall layout. Wall layout shall be performed by the contractor or contractor's representative. Temporary Micropile and Ground Nail Walls General Notes September 4, 2018 Duncan Residence 533 West Hallam Street 18-029G-D1 Grade-4 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Sheet Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For:Seal: 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 WEST SIDE Station 0+30 Ground Nail NORTH SIDE Station 1+10 Ground Nail EAST SIDE Station 1+90 Micropile SOUTH SIDE Station 2+50 Micropile Temporary Micropile and Ground Nail Walls Sections September 4, 2018 Duncan Residence 533 West Hallam Street 18-029G-D1 Grade-5 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Sheet Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For:Seal: Notes: 1. The micropile and ground nail walls shall be constructed entirely within property boundaries. 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 SCALE: HORIZONTAL 1" = 10' VERTICAL 1" = 10' ABBREVIATIONS EG - Existing Grade TOW - Top of Wall BOE - Bottom of Excavation Injection Bar Field Installed Grout MICROPILE CROSS SECTION A-A' Borehole MICROPILE BEARING PLATE FRONT VIEW 6" Micropile Hole Diameter = Bar Diameter +1/4" 6" 1/2" Min Hex Nut Bearing Plate MICROPILE DETAIL Grout A'A Williams Injection Bar 6" Min 9" Column MICROPILE BEARING PLATE SIDE VIEW Cross Bar, 24" OC Vertical Pile MICROPILE CAP PLAN VIEW VERTICAL SYSTEM MICROPILE CAP CROSS SECTION VERTICAL SYSTEM 12" 18" Cross Bar, #4 Rebar Continuous Waler, #4 Rebar 3" 2" min. 3,000 psi Concrete Grout Vertical Pile Continuous Waler, #4 Rebar Notes: Vertical piles 12" center to center with back row at 12" offset 12" 12" Continuous Waler, #4 Rebar Continuous Waler, #4 Rebar TYPICAL SECTION MICROPILE WALL 14.0' MAX CUT EXISTING GRADE VARIES PROPOSED EXCAVATION RL = 2 5 ' MICROPILE CAP SEE DETAILS 2' MAX. DH=14.0' MAX. WILLIAMS B7X1-51 INJECTION BAR BOTTOM OF EXCAVATION (SEE SHEET GRADE-3) SEE SHEET GRADE-3 FOR TOP OF CAP/WALL EL. PROPOSED TEMPORARY EXCAVATION AT 1H:1V PROPOSED TEMPORARY EXCAVATION AT 1.5H:1V NOTES: 1. SHOTCRETE REINFORCING STEEL NOT SHOWN FOR CLARITY MAXIMUM WALL HEIGHT (DH) VERTICAL SPACING (SV) HORIZONTAL SPACING (SH) REINFORCEMENT LENGTH (RL) REINFORCEMENT BAR 14.0 FEET #8 GRADE 75 ALL THREAD OR WILLIAMS B7X1-32 INJECTION BAR SEE SHEET GRADE-3 5 FEET 5 FEET REINFORCEMENT SCHEDULE Bottom of Shoring/Wall* Top of Shoring/Wall* 3 ft. max. Maximum Design Height = DH Varies SV 3 ft. max. * SEE SHEET GRADE-3 FOR TOP AND BOTTOM OF WALL/EXCAVATION ELEVATIONS TYPICAL SECTION TEMPORARY GROUND NAIL WALL Existing ground surface nearly level Strip drains shall be 12 inches wide and placed 10-foot on center and shall not extend within 18 inches of top of shotcrete Shotcrete batter vertical to 5 degrees Daylight strip drains Shotcrete 4-inch min. RL Temporary Excavation at 1H:1V max. GROUND NAIL SHOTCRETE DETAIL B' B GROUND NAIL CROSS SECTION B-B' 4-INCH MIN. GROUND NAIL BEARING PLATE FRONT VIEW 8" 8" MESH OVERLAP MIN 2 GRIDS SHOTCRETE REINFORCEMENT FRONT VIEW 1/2" MIN 4" GROUND NAIL BEARING PLATE SIDE VIEW GROUND NAIL BEARING PLATE WELDED WIRE FABRIC 4"x4" - W2.9xW2.9 HORIZONTAL BEARING BARS (2) #4 @ 6" OC (CONTINUOUS) VERTICAL BEARING BARS (2) #4 @ 6" OC 30" MIN. LENGTH GROUND NAIL HOLE DIAMETER = BAR DIAMETER + 1 4" SHOTCRETE GEOCOMPOSITE STRIP DRAIN WELDED WIRE MESH SHOTCRETE VERTICAL BEARING BAR BEARING PLATE HEX NUT HORIZONTAL WALERS SHOTCRETE FACING GROUT CENTRALIZER @ MAX 10 FT. OC AND WITHIN 2 FT. OF THE TOP AND BOTTOM OF DRILLHOLE (NOT REQUIRED FOR INJECTION BARS) GRADE 75 ALL-THREAD OR WILLIAMS INJECTION BAR BOREHOLE GROUT BAR NOTE: Use soil nail details for shotcrete waler on Micropile Wall - System 4 Temporary Micropile and Ground Nail Walls Typical Sections and Details September 4, 2018 Duncan Residence 533 West Hallam Street 18-029G-D1 Grade-6 of 6 RDJ Project Number: Date:Sheet Number:Prepared by:Project: Sheet Revisions Date Revision/Issue Prepared by B&Y Drilling, Inc. Designed For:Seal: NOT TO SCALE Abbreviations: RL - Reinforcement Length DH - Design Height 266 Red Cliff Circle Glenwood Springs, CO 81601 Phone: (970) 230-9208 NOTES: 1. See Sheet Grade-3 for top of wall/cap and bottom of excavation elevations. Alex Ewers, P.E.53341 Project Engineer Vicinity Map Duncan Skihaus 533 W. Hallam St. Aspen, CO 81611 Sheet Index Project Address Scope of Work Development of 533 W. Hallam St. shall include grading, drainage, utilities & general civil work. HPC Submission July 3, 2018 118 West Sixth Street, Suite 200 Glenwood Springs, CO 81601 970.945.1004 www.sgm-inc.com Duncan Skihaus LLC 533 W. Hallam St. 1-Cover Cover Sheet G1 General Notes G2 Legend and Abbreviations V1 Survey Plat C1 Demolition Plan C2 Site Plan C3 Utility Plan C4 Grading & Drainage Plan C5 Erosion Control Plan C6 Details (1) C7 Details (2) Title: Cover Re v i s i o n # Dwg No. Du n c a n S k i h a u s L L C 55 3 W . H a l l a m S t . Job No. Drawn by: Date: File: QC: 2018-292.001 JB 07.03.18 AE Dun-Cover 11 8 W e s t S i x t h S t r e e t , S u i t e 2 0 0 Gl e n w o o d S p r i n g s , C O 8 1 6 0 1 97 0 . 9 4 5 . 1 0 0 4 w w w . s g m - i n c . c o m Da t e By : 1-COVER 11Of : PE:RB Pr e l i m i n a r y N o t F o r C o n s t r u c t i o n Pr o j e c t M i l e s t o n e : Not to Scale Title: General Notes Re v i s i o n # Dwg No. Du n c a n S k i h a u s L L C 55 3 W . H a l l a m S t . Job No. Drawn by: Date: File: QC: 2018-292.001 JB 07.03.18 AE Dun-Cover 11 8 W e s t S i x t h S t r e e t , S u i t e 2 0 0 Gl e n w o o d S p r i n g s , C O 8 1 6 0 1 97 0 . 9 4 5 . 1 0 0 4 w w w . s g m - i n c . c o m Da t e By : G1 11Of : PE:RB Pr e l i m i n a r y N o t F o r C o n s t r u c t i o n Pr o j e c t M i l e s t o n e : Title: Legend and Abbreviations Re v i s i o n # Dwg No. Du n c a n S k i h a u s L L C 55 3 W . H a l l a m S t . Job No. Drawn by: Date: File: QC: 2018-292.001 JB 07.03.18 AE Dun-Cover 11 8 W e s t S i x t h S t r e e t , S u i t e 2 0 0 Gl e n w o o d S p r i n g s , C O 8 1 6 0 1 97 0 . 9 4 5 . 1 0 0 4 w w w . s g m - i n c . c o m Da t e By : G2 11Of : PE:RB Pr e l i m i n a r y N o t F o r C o n s t r u c t i o n Pr o j e c t M i l e s t o n e : Linetypes Legend Symbols Hatching Abbreviations 12" 18" 20" 8" 10" 3" 2" 6" 18" 12" 12" 8" 10" 8" 6" 3" 3" 4" 10" 4"8" 8" 10" 4" 4" 6" 8"30" Graphic Scale In Feet: 1" = 5' 0 3 5 10 Title: Demolition Plan Re v i s i o n # Dwg No. Du n c a n S k i h a u s L L C 55 3 W . H a l l a m S t . Job No. Drawn by: Date: File: PE:QC: 2018-292.001 JB 07.03.18 AE Dun-Demo RB 11 8 W e s t S i x t h S t r e e t , S u i t e 2 0 0 Gl e n w o o d S p r i n g s , C O 8 1 6 0 1 97 0 . 9 4 5 . 1 0 0 4 w w w . s g m - i n c . c o m Da t e By : C1 11Of : Pr e l i m i n a r y N o t F o r C o n s t r u c t i o n Pr o j e c t M i l e s t o n e : Graphic Scale In Feet: 1" = 5' 0 3 5 10 Title: Site Plan Re v i s i o n # Dwg No. Du n c a n S k i h a u s L L C 55 3 W . H a l l a m S t . Job No. Drawn by: Date: File: PE:QC: 2018-292.001 JB 07.03.18 AE Dun-Site RB 11 8 W e s t S i x t h S t r e e t , S u i t e 2 0 0 Gl e n w o o d S p r i n g s , C O 8 1 6 0 1 97 0 . 9 4 5 . 1 0 0 4 w w w . s g m - i n c . c o m Da t e By : C2 11Of : Pr e l i m i n a r y N o t F o r C o n s t r u c t i o n Pr o j e c t M i l e s t o n e : Graphic Scale In Feet: 1" = 10' 0 5 10 20 Title: Utility Plan Re v i s i o n # Dwg No. Du n c a n S k i h a u s L L C 55 3 W . H a l l a m S t . Job No. Drawn by: Date: File: PE:QC: 2018-292.001 JB 07.03.18 AE Dun-Site RB 11 8 W e s t S i x t h S t r e e t , S u i t e 2 0 0 Gl e n w o o d S p r i n g s , C O 8 1 6 0 1 97 0 . 9 4 5 . 1 0 0 4 w w w . s g m - i n c . c o m Da t e By : C3 11Of : Pr e l i m i n a r y N o t F o r C o n s t r u c t i o n Pr o j e c t M i l e s t o n e : Graphic Scale In Feet: 1" = 5' 0 3 5 10 Title: Grading & Drainage Plan Re v i s i o n # Dwg No. Du n c a n S k i h a u s L L C 55 3 W . H a l l a m S t . Job No. Drawn by: Date: File: PE:QC: 2018-292.001 JB 07.03.18 AE Dun-Gr RB 11 8 W e s t S i x t h S t r e e t , S u i t e 2 0 0 Gl e n w o o d S p r i n g s , C O 8 1 6 0 1 97 0 . 9 4 5 . 1 0 0 4 w w w . s g m - i n c . c o m Da t e By : C4 11Of : Pr e l i m i n a r y N o t F o r C o n s t r u c t i o n Pr o j e c t M i l e s t o n e : Graphic Scale In Feet: 1" = 5' 0 3 5 10 Title: Erosion Control Plan Re v i s i o n # Dwg No. Du n c a n S k i h a u s L L C 55 3 W . H a l l a m S t . Job No. Drawn by: Date: File: PE:QC: 2018-292.001 JB 07.03.18 AE Dun-Erosion RB 11 8 W e s t S i x t h S t r e e t , S u i t e 2 0 0 Gl e n w o o d S p r i n g s , C O 8 1 6 0 1 97 0 . 9 4 5 . 1 0 0 4 w w w . s g m - i n c . c o m Da t e By : C5 11Of : Pr e l i m i n a r y N o t F o r C o n s t r u c t i o n Pr o j e c t M i l e s t o n e : 24" - 30"** 12" 6" MOUNTABLE CURB & GUTTER - TYPE A (Catch Type for Typical Edge of Street) R=1.5" 4" 6" 6" R=0.25" R=0.25" Note: Concrete must conform to CDOT Class "D" (minimum 28-day compressive strength of 4500 psi). 80% of this strength must be gained in the first 7 days. **Width of Curb and Gutter dependent on designated location for installation 1"/FT (MAX) Graphic Scale In Feet: 1" = 1' 0 1 1 2 Title: Details (1) Re v i s i o n # Dwg No. Du n c a n S k i h a u s L L C 55 3 W . H a l l a m S t . Job No. Drawn by: Date: File: PE:QC: 2018-292.001 JB 07.03.18 AE Dun-Details-1 RB 11 8 W e s t S i x t h S t r e e t , S u i t e 2 0 0 Gl e n w o o d S p r i n g s , C O 8 1 6 0 1 97 0 . 9 4 5 . 1 0 0 4 w w w . s g m - i n c . c o m Da t e By : C6 11Of : Pr e l i m i n a r y N o t F o r C o n s t r u c t i o n Pr o j e c t M i l e s t o n e : Graphic Scale In Feet: 1" = 1' 0 1 1 2 Title: Details (2) Re v i s i o n # Dwg No. Du n c a n S k i h a u s L L C 55 3 W . H a l l a m S t . Job No. Drawn by: Date: File: PE:QC: 2018-292.001 JB 07.03.18 AE Dun-Details-1 RB 11 8 W e s t S i x t h S t r e e t , S u i t e 2 0 0 Gl e n w o o d S p r i n g s , C O 8 1 6 0 1 97 0 . 9 4 5 . 1 0 0 4 w w w . s g m - i n c . c o m Da t e By : C7 11Of : Pr e l i m i n a r y N o t F o r C o n s t r u c t i o n Pr o j e c t M i l e s t o n e : W1 W1 W1 W1 D1 D1 D1 D1 D1 D1 D1 W1 ST1 D3 D3 D3D3 ST1 ST1 ST1 ST1 ST1 ST1 ST1 VICTORIAN DECORATIVE SCONCE AT ENTRY VICTORIAN DECORATIVE SCONCE AT ENTRY 1 2" DIAMETER RECESSED PINSPOT DOWNLIGHTS SHORT PATHLIGHTS, LIGHTS DOWN TOWARDS PATH SHORT PATHLIGHTS, LIGHTS DOWN TOWARDS EDGE OF PATIO SHORT PATHLIGHTS, LIGHTS DOWN TOWARDS PATH TYPICAL: MONOPOINT DOWNLIGHT BELOW GRADE, INSIDE LIGHT WELL - FOR EGRESS ILLUMINATION VICTORIAN DECORATIVE SCONCE AT ENTRY SHORT PATHLIGHTS, LIGHTS DOWN TOWARDS PATIO GRADE CHANGE 1 2" DOWNLIGHTS, INTEGRATED WITH ARCHITECTURE TO LIGHT DOWN AT GARAGE ENTRY. LESS THAN 1" DIAMETER RECESSED PINSPOT DOWNLIGHTS VICTORIAN DECORATIVE SCONCE AT ENTRY ST1 ST1 D2 D2 D2 D2 D2 D2 D2 D2 ST1 D2 D2 D2 D2 1 2" DOWNLIGHTS, INTEGRATED WITH ARCHITECTURE TO LIGHT DOWN AT GARAGE ENTRY. DU N C A N S K I H A U S AS P E N , C O L O R A D O 1 8 6 L I G H T I N G D E S I G N G R O U P ,I N C . 1200 BANNOCK ST. DENVER, CO 80204 TEL:303.534.5350 www.186group.com DATE REVISION & ISSUE 2018-07-03 HPC REVIEW SHEET NUMBER: PAGE TITLE: EL-1.0 EXTERIOR LIGHTING PLAN EXTERIOR LIGHTING PLAN 1/4" = 1'-0" NOT FOR CONSTRUCTION