Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.728 E Hopkins Ave.0186.2019 (45).ARBK
TENMAT Inc. 23 Copper Drive Newport, DE 19804 T: 302-633-6600 F: 302-633-6838 E: info@tenmatusa.com FF109-300 1 Hour Fire Rated Light Cover Technical Product Specification Model Number Inside Height Outside Diameter FF109-300 7 3/8” 14 1/4” Performance Data For Use: UL Classified to maintain the fire rating (1 hour) for the following fire-rated floor/ceiling assemblies: L500 series General Information Benefits: 60 minute protection. Fits most popular IC rated fixtures. For use with recessed incandescent, fluorescent or LED light fixtures. Can be used in L500 floor/ceiling assemblies. Lightweight (approx. 1.5 lbs). Easy Installation - can be fitted in seconds - no screws, drilling or additional sealant required. Flexible material enables the cover to be fitted around obstacles or retro-fitted. Enhances the acoustic protection of the ceiling. Maintenance free. CLASSIFIED FOR FIRE RESISTANCE FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY The FF109-300 UL Fire Rated cover is a dome-shaped cover which has been designed to help maintain the integrity of fire rated ceilings for one hour when using recessed light fixtures. The unique design gives the architect, specifier and installer more freedom in fixture selection as the covers are suited to a wide range of recessed lights. 10/21/2019 Model Number Inside Height Inside Diameter FF109-300 7 3/8” 13” Performance Data For Use: • UL Classified to maintain the fire rating (1 hour) for the following fire-rated floor/ceiling assemblies: UL L500 series General Information Benefits: • 60 minute protection. • Fits most popular IC rated fixtures. • Can be used in L500 floor/ceiling assemblies. • Lightweight (approx. 1.5 lbs). • Easy Installation - can be fitted in seconds - no screws, drilling or additional sealant required. • Flexible material enables cover to be fitted around obstacles or retro-fitted. • Enhances the acoustic protection of the ceiling. • Reduces heat loss through the fixture. • Significant energy cost savings. • Maintenance free. Manufactured By Tenmat Inc 23 Copper Drive Newport, DE 19804 Phone: (302) 633-6600 Fax: (302) 633-6838 Email: info@tenmatusa.com www.tenmatusa.com TENMAT MODEL FF109-300 Technical Product Specifications CLASSIFIED FOR FIRE RESISTANCE FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY 10/21/2019 7/27/2018 CDHW.R25019 - Luminaires, Luminaire Assemblies and Luminaire Enclosures Certified for Fire Resistance http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/showpage.html?name=CDHW.R25019&ccnshorttitle=Luminaires,+Luminaire+Assembli…1/1 CDHW.R25019 Luminaires, Luminaire Assemblies and Luminaire Enclosures Certified for Fire Resistance Page Bottom Luminaires, Luminaire Assemblies and Luminaire Enclosures Certified for Fire Resistance See General Information for Luminaires, Luminaire Assemblies and Luminaire Enclosures Certified for Fire Resistance TENMAT INC R25019 UNIT 3 23 COPPER DR NEWPORT, DE 19804 USA Type FF109 Fire Rated Recessed Light Cover luminaire enclosure for use over UL Listed IC-rated recessed incandescent, fluorescent or LED luminaires with housing 6-7/8 in. max. diam, 6-7/8 in. max. height (as measured from top of base), made from aluminum or painted or galv steel. Luminaires supported on a base 7-7/8 in. by 10-3/4 in. max., made from painted or galv steel and screw-attached to the fixture with min. three screws. Each luminaire with trim and lens weighs 3.8 lb max. Luminaire enclosure and luminaire installed in accordance with the accompanying instructions. Luminaire enclosure and luminaire for use in 1 hr fire rated L500-Series Floor-Ceiling designs having solid wood joists, open-web wood trusses or I-shaped wood joists on max 16 in. centers, wood flooring and a min 1/2 in. thick gypsum board ceiling. Number of luminaires not to exceed the ratio of one per 25 sq ft of total ceiling area with min separation of 3 ft between luminaires. Type FF109X Fire Rated Recessed Light Cover luminaire enclosure for use over UL Listed IC-rated recessed incandescent, fluorescent or LED luminaires with housing 6-1/2 in. max. diam, 7 in. max. height (as measured from top of base), made from aluminum or painted or galv steel. Luminaires supported on a base 7-1/2 in. by 10 in. max., made from painted or galv steel and screw-attached to the fixture. Each luminaire with trim and lens weighs 3.8 lb max. Luminaire enclosure and luminaire installed in accordance with the accompanying instructions. Luminaire enclosure and luminaire for use in maximum 2 hr fire rated D500-, G500- and L500-Series Floor-Ceiling designs and in maximum 1 hr fire rated P500-Series Roof-Ceiling designs. Number of luminaires not to exceed the ratio one per 25 sq ft of total ceiling area with min separation of 3 ft between luminaires. Luminaire enclosure and luminaire for use in maximum 2 hr fire rated D200-, G200-, J200- and L200-Series Floor-Ceiling designs and in maximum 1 hr fire rated P200-Series Roof-Ceiling designs with nominal 24 by 24 in. or 24 by 48 in. acoustical lay-in ceiling panels. Number of luminaires not to exceed the ratio of one per 25 sq ft of total ceiling area with min separation of 4 ft between luminaires. Type FF130 Series Fire Rated Troffer Cover luminaire enclosure for use as an alternate Fixture Protection for UL Listed fluorescent or UL-certified LED retrofitted recessed troffer light fixtures with steel housings in the following Designs for 1 hr max ratings: D216, D219, G205, G208, G218, G252, G255, G256, G262, G264, J201, J202, L006, L201, L202, L206, L209, L210, P202, P204, P206, P207, P210, P211, P213, P214, P216, P225 , P227, P228, P229, P230, P231, P235, P238, P242, P246, P250, P251, P254, P255, P259, P260, P261, P264, P265, P267, P268, P269. The recessed light fixture installation method and spacing requirements shall be as specified in the individual Design. Enclosure shall be installed in accordance with the accompanying instructions. A 1/2 in. clearance shall be maintained between the top, sides and ends of the fixture and the enclosure. For nominal 2 by 2 ft fixtures, a nominal 4 in. by 4 in. piece of mineral wool batt or acoustical material shall be placed on top of the fixture prior to installation. For nominal 2 by 4 ft fixtures, two pieces shall be used, one on top of each end. The height of the fixture housing shall be limited such that it will not cause the bottom of the cover to lose contact with the ceiling tiles. End-to-end or side-by-side installation of fixtures has not been investigated. Type FF130-2'x2' and Type FF130-2'x4' enclosures for use with nominal 2 by 2 ft and 2 by 4 ft recessed light fixtures, respectively. Type FF130-600x600mm and Type FF130-600x1200mm enclosures for use with nominal 600 by 600 mm and 600 by 1200 mm recessed light fixtures, respectively. Last Updated on 2018-07-19 Questions?Print this page Terms of Use Page Top © 2018 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2018 UL LLC". 10/21/2019 St e p 1 St e p 2 St e p 3 St e p 4 Place Tenmat FF109 cover over the fixture. Slit the cover to fit over the hanger bars of the fixture. Cut four slits with a size up to 1” max. Put the cover on top of the fixture. Check for secure fit, and make sure the cover overhangs the hanger bars. The FF 109 Light Cover must fit flush with the back surface of the drywall board. The wire can be fed through one of the cover vent holes located at the top. Follow the light manufacturer instructions to make proper connections. Hanger bars of the light fixture shall be screwed to the joists in addition to the tabs being hammered into the joists, following the light manufacturer’s installation instruction. WARNING: BE SURE THE ELECTRICITY TO THE SYSTEM YOU ARE WORKING ON IS TURNED OFF; EITHER THE FUSE REMOVED OR THE CIRCUIT BREAKER SET AT OFF. CONTAINS STONE WOOL INSULATION Stone fibers may cause temporary mechanical irritation to the skin, throat, nose and eyes. FIRST AID Skin If irritation occurs, do not rub or scratch. Rinse under running water prior to washing with mild soap and water. Consult a physician if irritation persists. Throat and Eyes If irritation occurs, flush eyes with water and/or drink water to clear throat. Do not rub the eyes. Consult a physician if irritation persists. PRECAUTIONS Wear long sleeve, loose fitting clothing, gloves and eye protection. For additional information, refer to the Material Safety Data Sheet (MSDS). Type FF109 Fire Rated Recessed Light Cover luminaire enclosure for use over UL Listed IC-rated recessed incan- descent and fluorescent luminaires with housing 6-7/8 in. max. diam, 6-7/8 in. max. height (as measured from top of base), made from aluminum or painted or galv steel. Lumi- naires supported on a base 7-7/8 in. by 10-3/4 in. max., made from painted or galv steel and screw-attached to the fixture with min. three screws. Each luminaire with trim and lens weighs 3.8 lb max. Luminaire enclosure and luminaire installed in accordance with the accompanying instructions. Luminaire enclosure and luminaire for use in 1 hr fire rated L500-Series Floor-Ceiling designs having solid wood joists or open-web wood trusses on max 16 in. centers, wood flooring and a min 1/2 in. thick gypsum board ceiling. Num- ber of luminaires not to exceed the ratio of one per 25 sq ft of total ceiling area with min separation of 3 ft between luminaires. CLASSIFIED FOR FIRE RESISTANCE FIRE RESISTANCE CLASSIFICATION SEE UL FIRE RESISTANCE DIRECTORY FF109-300 1 Hour Fire Rated Light Cover TENMAT Inc. 23 Copper Drive Unit 5 Newport, DE 19804 T: 302-633-6600 F: 302-633-6838 E: info@tenmatusa.com IN S T A L L A T I O N I N S T R U C T I O N 10/21/2019