HomeMy WebLinkAboutFile Documents.728 E Hopkins Ave.0186.2019 (46).ARBKFF109-350
1 Hour Fire Rated Light Cover
TENMAT Inc. 23 Copper Drive Newport, DE 19804 T: 302-633-6600 F: 302-633-6838 E: info@tenmatusa.com
The FF109-350 is the larger version of
the FF109-300 and suitable for lights up
to 8”.
Both covers are made out of the same
intumescent material and exhibit
excellent thermal and acoustical
insulating properties.
The FF109-350 has an inside height of
10 3/8” and a diameter of 15” to fit the
most common recessed light housings.
Technical Product Specification
Model
Number
Inside
Height
Outside
Diameter
FF109-350 10 3/8” 17”
Performance Data
For Use:
Warnock Hersey - Intertek certified to maintain the fire
rating (1 hour) of fire-rated floor/ceiling assemblies.
General Information
Benefits:
60 minute protection.
Fits most popular recessed light fixtures.
For use with recessed incandescent, fluorescent or LED
light fixtures.
Can be used in L500 floor/ceiling assemblies.
Lightweight (approx. 2.5 lbs).
Easy Installation - can be fitted in seconds - no screws,
drilling or additional sealant required.
Flexible material enables the cover to be fitted around
obstacles or retro-fitted.
Enhances the acoustic protection of the ceiling.
Maintenance free.
Tested to ASTM E119 UBC 7 1 NFPA 251 ASI A2.1
10/21/2019
Model
Number
Inside
Height
Inside
Diameter
FF109-350 10 3/8” 15”
Performance Data
For Use:
Warnock Hersey - Intertek certified to maintain the fire
rating (1 hour) of fire-rated floor/ceiling assemblies.
General Information
Benefits:
60 minute protection.
Fits most popular recessed light fixtures.
Can be used in L500 floor/ceiling assemblies.
Lightweight (approx. 2.5 lbs).
Easy Installation - can be fitted in seconds - no screws,
drilling or additional sealant required.
Flexible material enables the cover to be fitted around
obstacles or retro-fitted.
Enhances the acoustic protection of the ceiling.
Reduces heat loss through the fixture.
Significant energy cost savings.
Maintenance free.
Manufactured By
Tenmat Inc
23 Copper Drive
Newport, DE 19804
Phone: (302) 633-6600
Fax: (302) 633-6838
Email: info@tenmatusa.com
www.tenmatusa.com
TENMAT
MODEL FF109-350
Technical Product Specifications
Tested to ASTM E119
UBC 7 1
NFPA 251
ASI A2.1
10/21/2019
10/21/2019
10/21/2019
10/21/2019
10/21/2019
10/21/2019
FF109-350
1 Hour Fire Rated Light Cover
St
e
p
1
St
e
p
2
St
e
p
3
St
e
p
4
Place Tenmat FF109 cover over the fixture.
Slit the cover to fit over the hanger bars of the fixture.
Cut four slits with a size up to 1” max.
Put the cover on top of the fixture. Check for secure fit, and make
sure the cover overhangs the hanger bars.
The FF 109 Light Cover must fit flush with the back surface of the
drywall board.
The wire can be fed through one of the cover vent holes located at
the top.
Follow the light manufacturer instructions to make proper
connections.
Hanger bars of the light fixture shall be screwed to the joists in
addition to the tabs being hammered into the joists, following the light
manufacturer’s installation instruction.
WARNING: BE SURE THE ELECTRICITY TO THE SYSTEM YOU ARE WORKING ON IS
TURNED OFF; EITHER THE FUSE REMOVED OR THE CIRCUIT BREAKER SET AT OFF.
CONTAINS STONE WOOL INSULATION
Stone fibers may cause temporary mechanical irritation to the skin, throat, nose and eyes.
FIRST AID
Skin
If irritation occurs, do not rub or scratch. Rinse under running water prior to washing with
mild soap and water. Consult a physician if irritation persists.
Throat and Eyes
If irritation occurs, flush eyes with water and/or drink water to clear throat. Do not rub the
eyes. Consult a physician if irritation persists.
PRECAUTIONS
Wear long sleeve, loose fitting clothing, gloves and eye protection.
For additional information, refer to the Material Safety Data Sheet (MSDS).
Ensure the cover fits your chosen
recessed light fixture.
FF109-350 Overall Dimensions:
Inside Diameter 15”
Inside Height 10 3/8”
TENMAT Inc. 23 Copper Drive Unit 5 Newport, DE 19804 T: 302-633-6600 F: 302-633-6838 E: info@tenmatusa.com
IN
S
T
A
L
L
A
T
I
O
N
I
N
S
T
R
U
C
T
I
O
N
10/21/2019