WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier. What To Do If You Smell Gas tDo not try to light any appliance. tDo not touch any electrical switch. tDo not use any phone in your building. tImmediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions. tIf you cannot reach your gas supplier call the fi re department. Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit is used. This appliance is suitable for installation in a bedroom or bed sitting room.MODEL: TCWS54 SERIES D MODULAR DIRECT VENT FIREPLACE TCWS54D- Version 2 INSTALLATION MANUAL 150817-40 TCWS54_D.Ver2 5056.4252155D Visit www.townandcountryfi replaces.com for the most recent version of this manual INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. 4/04/2019 5056.4252155D Table of Contents Caution ......................................................................................3 Safety ........................................................................................3 Important Note for the Commonwealth of Massachusetts .......4 Fireplace Dimensions ................................................................5 Minimum Clearances to Combustible Material .........................5 Installation Requirements ..........................................................6 Manufactured (Mobile) Home ....................................................6 Window Frame Removal ...........................................................6 Top Standoffs ............................................................................7 Locating The Fireplace ..............................................................7 Framing and Finishing ...............................................................8 Removing LED light wire retaining clip ..............................9 TCWS54D Minimum Combustible Framing Dimensions ........10 Non - combustible board area .........................................10 Steel Stud Framing Kit ............................................................11 Frame Assembly ..............................................................12 Fixed Lintel ..............................................................................13 Framing Kit Adjustment ....................................................13 Fireplace Facing Allowance ...........................................14 Electrical ..................................................................................14 Installation ........................................................................14 Lintel knock outs ..............................................................14 Wall Switch and Remote Control .............................................16 Linking the remote control unit to the wall switch............ 16 Wall Switch to IFC Communication Cable Continuity Check ..16 Selecting Natural Vent and Power Vent Modes ....................... 17 Home Automation ...................................................................18 Gas Supply ..............................................................................19 Gas Pressure Check ................................................................19 Correct gas pressure requirement:................................... 19 Venting .....................................................................................20 Wall Termination Venting .........................................................20 Vent System Components ...............................................20 Roof Termination Venting ........................................................21 Ceiling Opening: ...............................................................21 Ceiling Firestop: ...............................................................21 Vent Pipe: .........................................................................21 Roof Support Bracket: .....................................................21 Roof Termination Venting Chart ............................................... 22 Roof Vent Terminal: ..........................................................23 Vent Terminal Minimum Clearances ........................................24 Vent Terminal Clearance ..........................................................25 Roof Pitch Table ...............................................................25 Vent Pipe Sealant ....................................................................25 Vent Restrictor Adjustment .....................................................26 Roof Termination Kit ................................................................27 Vent Pipe Dimensions .............................................................28 Vent Offset Chart .....................................................................29 Firebox Panels Installation ......................................................30 Installing fi rebox panels into a “D” series fi replace. .........30 Finishing Touch Trim Kit Instructions .......................................31 Linking Remote Handset to the Fireplace ...............................32 Step 1: Procedure for linking / pairing wall switch to fi replace ................................................32 Step 2: Procedure for linking / pairing the wall switch to remote handset ...................................33 Maintenance ............................................................................34 Glass Panel ......................................................................34 Annual Inspection: ............................................................34 Periodically: ......................................................................34 TCWS.54D Replacement Parts ...............................................35 Replacement Parts – Valve Control System ............................36 Wiring Diagram ........................................................................37 Quick Panel Removal for Valve Service ..................................38 Rating Label ............................................................................39 Attention! rTurn off the main gas supply for the appliance during installation or maintenance of the receiver/ module device. rTurn off main gas supply for the appliance prior to removing or reinserting the batteries. rIn case of remote control mal- function, turn off the fi replace using the “on/off” main switch located on the wall. rFor installation/maintenance, turn off the fi replace at the on/off switch located on the wall and at the fi replace power supply circuit breaker. 2 TCWS54_D 150817-40 HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. !DANGER A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and shall be installed for the protection of children and other at-risk individuals. 4/04/2019 5056.4252155D Due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young chil- dren, and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at-risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children, and other at-risk individuals out of the room and away from hot surfaces. Clothing or other flammable material should not be placed on or near the appliance. Any grill, panel or door removed for servicing the unit must be replaced prior to operating. Failure to do so may create a hazardous condition. Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean. It is our policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result, either directly or indirectly, of any improper operation or installation procedures. This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance. FOR YOUR SAFETY - Do not install or operate your Town & Country fireplace without first reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Town & Country FireplacesTM Warranty and may prove hazardous. This appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). Note: When lit for the first time, the appliance will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants and lubricants used in the manufacturing process. This condition is temporary. Open doors and win- dows to ventilate area. Smoke and fumes caused by the curing process may cause discomfort to some individuals. Do not use the fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water. 3TCWS54_D 021216-40 Caution Safety We recommend that our gas hearth products be installed and serviced by professionals who are certified in the United States by the National Fireplace Institute® (NFI) as NFI Gas Specialists 4/04/2019 5056.4252155D 4 TCWS54_D 150817-40 Important Note for the Commonwealth of Massachusetts From Massachusetts Rules and Regulations 248 CMR 5.08: (a) For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied. 1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fuelled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed, in addition, the installing plumber or gas fitter shall observe that a battery operated or hard-wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fuelled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard-wired carbon monoxide detectors. a. In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic, the hard-wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. b. In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed. 2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certified. 3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”. 4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2) (a) 1 through 4. (b) EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4. 1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and 2. Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes. (c) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 1. Detailed instructions for the installation of the venting system design or the venting system components; and 2. A complete parts list for the venting system design or venting system. (d) MANUFACTURER REQUIREMENTS – GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fuelled equipment does not provide the parts for venting the fuel gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer. 1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and 2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions. (e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. 4/04/2019 5056.4252155D D 12” E 6 3/4” F 1 1/2” MANTEL CLEARANCE CHART * MANTEL CLEARANCE ** MANTEL DEPTH A 9” B 6” C 3” MAY USE COMBUSTIBLE FACING MATERIAL IN THIS AREA NON-COMBUSTIBLE FINISH MATERIAL SEE FIG #11 & 13 NON-COMBUSTIBLE ZONE. DO NOT INSTALL ANY COMBUSTIBLE MATERIAL, ELECTRICAL WIRING OR GAS PLUMBING IN THIS AREA. COMBUSTIBLE FRAMING AND FINISH WALL ABOVE STANDOFFS STANDOFFS STEEL FRAMING FIREPLACE FRONT TOP OF LINTEL BAR A B C D E F Figure 2: TCWS54D Mantel clearances. 29 3/4" 24" 4“ CEILING ADJACEN T W A L L OR MANT E L S U P P O R T 12” COMBUS T I B L E F L O O R COMBUST I B L E H E A R T H * ** Figure 3: TCWS54D Minimum mantel clearances. Minimum Clearances: Side standoffs ......................................................0 in. (0 mm) Back standoff .......................................................0 in. (0 mm) Top standoffs ........................................................0 in. (0 mm) Bottom of appliance .............................................0 in. (0 mm) Adjacent side wall ................................................4 in. (102 mm) Ceiling to appliance ............................................24 in. (610 mm) *Mantel to appliance ..............................See Figure #2 **Maximum Mantel extension ................See Figure #2 Mantel support .....................................................4 in. (102 mm) Vertical vent pipe .......................................... 1 3/4" in. (45 mm) 5TCWS54_D 021216-40 Fireplace Dimensions Minimum Clearances to Combustible Material 71 15/16" 55" 11 1/2" 18 5/8" 5 5/8" 35 3/4" 23 1/2" 25 5/16" 71 15/16" 54 7/16" 13 3/4" Figure 1: TCWS54 Dimensions. 4/04/2019 5056.4252155D Figure 6: Handle.Figure 4: Safety barrier screen. HANDLE SAFETY BARRIER SCREEN Figure 5: Accessing handle. 6 TCWS54_D 150817-40 The Town & Country Fireplace installation and venting must conform to the current CAN/CGA-B149 installation code (in Canada) or the current National Fuel Gas Code, ANSI Z223.1 (in the USA), and approved per local codes. Only qualified (licensed or trained) personnel should install this product. In the state of Massachusetts, only a licensed Plumber and Gas Fitter may install this product. In some jurisdictions, the Town & Country Fireplace may be installed in Manufactured Homes after the "first sale". Consult local codes for approval. The fireplace must be fastened in place. Install in accordance with the current standard Mobile Homes, CAN/CSA Z240 MH (in CANADA), and the Manufacturer's Home Construction and Safety Standard, Title 24 CFR, Part 3280 or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites and Communities ANSI/NFPA 501A (in the USA). Installation Requirements Manufactured (Mobile) Home Window Frame Removal Warning: Turn off the fireplace, and allow ample time for the unit to cool before proceeding. Caution: The ceramic glass is very fragile, and should be handled with care. The window frame is held in place by two spring-loaded latches that are operated by a one-piece latch handle. 1. Remove safety barrier screen (Figure 4) by prying the top portion of the screen toward you, then lift the screen from its tabs (inset) located at the base of the window frame. 2. Remove the TC Finishing Touch Trim Kit from the window frame. (If installed) 3. Using a screwdriver (Figure 5) or other similar object, push against the notch in the top of the latch and grab the bottom of the latch handle as it protrudes (Figure 6). Lift handle until latch hook disengages. Repeat for other side while holding glass so it does not tip out. 4. Tilt the top of the window frame out to clear the top edge of the unit. Grasp the sides of the frame and lift up and out to disengage from its bottom track. 5. Place the window frame in a safe place to avoid damage. 6. Re-assemble in reverse order. Latch handle should snap into place and be flush with window frame when engaged correctly. 7. Reinstall Trim Kit if required. 8. Reinstall safety barrier screen. TIP: To ensure glass is properly latched, grasp the top left and right sides of the glass frame, under moderate pressure it should pull forward and return to original position evenly on both sides. 4/04/2019 5056.4252155D TOP STANDOFFS Figure 7: TCWS54D Stand offs. Figure 8: TCWS54D Possible locations. The standoffs are shipped loose inside the fireplace and must be installed on the top and the side of the fireplace as shown in Figure 7. Do this once the fireplace is on site and in position. In planning the installation for the fireplace, it is necessary to determine where the unit is to be installed, location of vent system and where gas supply piping may be plumbed. Various installations are possible, such as, into an existing wall, a corner, a built-in wall or a wall projection (Figure 9). Due to high temperatures, do not locate this fireplace in areas of high traffic or near furniture or draperies. The minimum clearances from the fireplace to combustible surfaces must be adhered to and are shown in Figure 2 and Figure 3. HANDLE 7TCWS54_D 021216-40 Locating The Fireplace Top Standoffs CONTROL BOX 4/04/2019 NOTE: After frame is assembled, make sure to have the side of the frame without the screw holes facing toward the inside of the room. side of frame with screw holes Flat side of frame 74 3/4" 55 1/16" Figure 9: TCWS54D with steel frame. 5056.4252155D Note: The fireplace should be in place and venting installed before framing in or building an enclosure around the unit. The Town & Country fireplace must be framed in as described below or totally enclosed with non-combustible material, such as facing brick. Determine the total thickness of facing material to be used. A thickness of 3/4" will allow the finishing surface to be flush with the front of the unit. If preferred, additional masonry type non-combustible material can be installed above and to the sides up to 6 inches forward of the appliance. The finishing material must not interfere with glass frame access. A Steel Stud Framing Kit is supplied with the fireplace and must be used unless the fireplace is totally enclosed with non-combustible material. Assemble the framing kit as per the instructions on pages 11 - 13 of this manual. Attach the steel frame to the fireplace once the fireplace is in its final position. Secure the steel frame to the framing brackets on each side of the unit. Ensure that the studs are set back far enough to allow for thick- ness of finishing surface. The sides, back and top of the fireplace can be framed in up to the steel studs and the fireplace standoffs using conventional lumber. Consult local building codes for specific requirements. Due to high temperatures, non-combusti- ble backer board, such as cement board or its equivalent, must be used to sheet in the front of the fireplace, extending 12" below, 12” above and 9 5/8" to the side of the framing edge bars (Figure 11). Standard sheetrock (dry wall) may be used beyond this. If the backer board is not to be finished with other non-combustible material such as tiles, it is recommended that top sec- tions of the board be a single sheet of calcium silicate board or its equivalent. Taped and mudded joints may crack due to the elevated temperatures. Chase Insulation: When installing this fireplace against a non-insulated exterior wall or chase, it is recommended that the outer walls be insulated to same degree as other exte- rior walls. Do not place fireplace directly against the insulation. Cover the insula- tion and plastic vapour barrier with a solid surface, such as dry wall (sheet rock). Consult local codes. Do not insulate or use plastic vapour barrier within the fram- ing kit. CAUTION: See “Figure 13” on page 10 BEFORE PROCEEDING. ALL OTHER FRAMING CAN BE DONE WITH CONVENTIONAL LUMBER NON-COMBUSTIBLE ZONE. DO NOT INSTALL ANY COMBUSTIBLE MATERIAL, ELECTRICAL WIRING, INSULATION, PLASTIC VAPOR BARRIER OR GAS PLUMBING WITHIN THE STEEL STUD FRAMING STEEL STUD FRAMING KIT DIMENSIONS (Supplied with fireplace) NOTE: The chase must be properly sealed at the ceiling level or between floors in a multi- level installation. 8 TCWS54_D 150817-40 Framing and Finishing 4/04/2019 5056.4252155D Figure 10: Light wiring retaining clip. NOTE: This fi replace ships with the light wiring secured in retaining clips. Remove light wiring from the retaining clip before installing and walling up the fi replace. NOTE: This fi replace ships with the light wiring secured in retaining clips. Remove light wiring from the retaining clip before installing and walling up the fi replace. Wire retaining clip 9TCWS54_D 021216-40 Removing LED light wire retaining clip 4/04/2019 5056.4252155D Figure 13: Non-combustible board location. NON-COMBUSTIBLE BOARD If fi nishing the wall above the unit with paint, the framing kit shipped with the unit should be discarded.Use full sheets of calcium silicate board or equivalent and full length metal studs to fi nish and frame around the unit. Calcium silicate board is a high grade material with cement, quartz and natural minerals as the main raw materials. (Note: Calcium Silicate is 1/2” thick) CAUTION: Calcium Silicate board can be damaged if dropped or struck. Handle with care. Inspect board prior to installation and do not use if cracked. NOTE: It is recommended to pre-drill mounting holes in the board prior to securing to the framing. This will pre- vent the board from cracking. 12 ” 9 5/8” 12” Figure 11: Non-combustible board within frame. NON-COMBUSTIBLE RECESSED INSTALLATION DETAIL This fi replace may be recessed up to a maximum depth of 4 1/2”. This recess must be constructed from non- combustible material. Finishing material must not pro- trude past framing fl anges under ANY circumstance. The safety screen and the window, with trim fi tted, must be able to move freely. Figure 12: TCWS54D Reccessed installation details. 31 1/2" 44 9/16" 74 13/16" 81 11/16" 81 11/16" 115 9/16" 55 1/4" 74 13/16" NOTE: FIREPLACE SHOULD BE IN ITS FINAL LOCATION BEFORE FRAMING RANGE 23 11/16" to 25 7/16" RANGE 25 3/8” to 26 7/8" RANGE 1/32" to 3 3/16" 11 3/4" FRAMING LINTEL 74 3/4" Figure 14: TCWS54D Minimum combustible framing. Non - combustible board area TCWS54D Minimum Combustible Framing Dimensions NON-COMBUSTIBLE MATERIAL MUST EXTEND 12" ABOVE, 9 5/8" TO THE SIDES AND 12” BELOW THE FRAMING EDGES. NON-COMBUSTIBLE BOARD 10 TCWS54_D 150817-40 4/04/2019 5056.4252155D 3 5 7 8 Figure 15: TCWS54D Framing kit. Each Kit Contains: FRONT VIEW (slightly angled) BEND OUT FRAMING TABS TO FRONT SCREW INTO SIDE Item Description Qty. 1 SCREW, WAFER #8 x 1/2 (Not shown) Pkg 40 2 STUD, SIDES 55” L 2 3 STUD, OUTER SIDES 55” L 2 4 STUD, UPPER/LOWER 74 3/4” L 2 4 4 2 266 3 Item Description Qty. 5 INNER CROSS BRACE 56 5/8 L 1 6 STUD, CENTER 25” L 3 7 LOWER CROSS BRACE 56 5/8 L 1 8 FRAMING PLATE 4 SLOPED SIDE DOWN 88 7 5 11TCWS54_D 021216-40 Steel Stud Framing Kit 4/04/2019 Framing plates located behind support brackets Access holes Figure 16: Aligning steel frame to fireplace. 5056.4252155D 1. On a flat surface, place 2 upper/lower studs (#4). One is to become the top-most horizontal stud and one is to become the bottom-most horizontal stud. Stand all pieces up on their narrow ends throughout assembly. 2. Place 3 center studs (#6) perpendicular to, and below the above horizontal beam at the beams 3 middle-most securing points. Make sure that the lower pointed ends of the center studs are closest to you. Use wafer screws (1) to join the top side of the vertical pieces to the horizontal piece. 3. Position Inner Cross Brace (#5) horizontally along the bottom ends of the 3 center studs (#6) and fasten with wafer screws to the center-most 3 positions along the cross brace. Cross brace should be perpendicular with the center studs and horizontal to the upper beam. 4. Position Side Studs (#2) at each end of the assembled frame so that the side studs are vertical and perpendicular to the upper stud and inner cross brace. Use wafer screws to fasten the side studs to the assembled frame. 5. Position the Lower Cross Brace (#7) - screen tab slots side up - between the two side studs and about 12” from the lower ends of the side studs. Attach each end of the lower cross brace to the side studs with wafer screws. 6. Place the lower horizontal beam at the bottom-most end of the frame. Attach the lower beam to the side studs leaving the ends of the lower horizontal beam extending out past the side studs so that it positioned in line with the upper horizontal beam. 7. Place and attach the two Outer Side studs at the ends of both the upper and lower beams and attach with wafer screws. 8. Once the top side of the frame is complete, turn it over so that the wafer screws can be used to fasten the other side of the frame. 9. Align the assembled frame to the unit framing plates (#8). Attach at the fastening points through the access holes (Figure 16) in the outer side studs (#3). NOTE: Sheet metal parts have sharp edges, use caution when handling. Frame Assembly 12 TCWS54_D 150817-40 4/04/2019 5056.4252155D Figure 17: Bend tab out 90 degrees. Fixed Lintel Figure 18: Attaching metal tab to frame. The lintel on the TCWS54D2 is in a fixed position on the fireplace and so there is no adjustment to move the lintel toward you or away from you once the fire- place has been located in its final position. Instead, the fireplace itself must be manoeuvered so that the front of the fireplace determines the final position. The Framing Kit allows for a 2 1/4 inch adjustment along the Framing Brackets. Use this range to help determine the front of the facing material. The thickness of the facing material, wether 1/2 inch calcium silicate board or a rock facing must be taken into consideration before settling on a final position of the fireplace. See “Fireplace Facing Allowance” on page 14. Framing Kit Adjustment Framing bracket Fixed lintel Figure 19: Fixed lintel and framing bracket. Attach the Assembled Frame and fireplace to the combustible framing. Bend out the tabs 90 degrees before inserting the unit into its framed housing (Figure 17). Attach the assembled framing kit to the Fireplace. Secure the frame assembly to the wood frame through the tabs (Figure 18). Install Non-Combustible Board Use drywall screws, to install the non-combustible board. 13TCWS54_D 021216-40 4/04/2019 5056.4252155D The gas control system is located on the right hand side of the fi rebox behind an access panel and the decorative fi rebox panel (if installed). The fi replace is operated via a wall control and a hand held remote control unit. The wall control is connected to the fi replace by a 40 ft. communication cable supplied with the fi replace. Electrical Note: Installation must be performed by a qulaifi ed installer, service agency or gas supplier. Installation 1. Place the fi replace in the desired location. 2. Remove the window from the fi replace. 3. Remove access panel from right hand side of the fi rebox (Figure 22). Lintel knock outs There are six knock outs on top of the lintel. These knock outs should remain in place and not knocked out during installation. The knock outs are for a future optional “TV KIT” which will allow a television to be mounted above the fi replace while having the heat from the fi replace re-directed to a vent which will be located above the TV. This fi replace is designed to fi nish either fl ush with the facing material or can be installed with a 4 1/2 inch recess, See “Figure 12: TCWS54D Reccessed installation details.” on page 10. The fi replace can accommodate facing material thickness from 1/2 of an inch to 2 1/4 inches if installing fl ush. Care should be taken to correctly determine the facing material thickness so that the fi replace is positioned so that the front of the fi replace is fl ush with the facing material. Facing material must not interfere with the ability for the door or the screen to open. Fireplace Facing Allowance Figure 20: Knock outs for future TV Kit feature. NON-COMBUSTIBLE FINISH MATERIAL NON-COMBUSTIBLE BUILDING MATERIAL MAY NOT EXTEND PAST THIS POINT SCREEN DOOR Figure 21: Facing edge location. 14 TCWS54_D 150817-40 4/04/2019 5056.4252155D Figure 22: Firebox access panel. JUNCTION BOX FIREBOX ACCESS PANEL 4. Lift the control box heat shield from the bottom opening to clear the location tabs and pull inwards. Lower the heat shield to clear the top tab. Lift the heat shield and locate on the screw above the opening. Note: The flex lines may have to be pushed down to allow the shield to be lowered enough to clear the top tab. 5. Connect 110 V. AC electrical supply to the wires installed inside the junction box (Figure 25). The fireplace is rated at 110 volts, 60Hz, 0.25A. The optional power vent kit is rated at 115 volts, 60Hz, 1.8A. 6. The electrical wires can be accessed from both inside and outside the junction box by removing one of the two small access panels (Figure 25 and Figure 26). 7. Attach the wall switch to the framing in the desired location (40 ft is supplied with fireplace). 8. Route the wall switch control cable (supplied) as required to the wall switch (Figure 28). 9. Attach one end of the wall switch control cable to the wall control (Figure 28), and the other end to the interface board (Figure 26). 10. Insert the 4 supplied “AA” batteries into the battery pack of the wall switch (Figure 29). 11. If not already installed, install the burner using the instructions supplied with the burner kit. 12. Turn on the gas supply and check that all connections are tight and leak free. 13. Turn on gas and electrical supplies. 14. Move the center button on the wall control (Figure 27) to the “ON” position. The igniter will start to spark. After a short delay delay, the pilot will light followed by the main burner. Figure 23: Heat shield raised.Figure 24: Heat shield. Figure 25: Junction box wiring. TransformerVacuum switch Inside access panel Gas connector Wall switch connector Junction box Module Interface board Power vent switch Regulator board Gas valve Figure 26: Control box. OUTER ACCESS PANEL 15TCWS54_D 021216-40 4/04/2019 5056.4252155D Figure 27: Town and Country wall switch. Figure 28: Wall switch - interface side. Linking the remote control unit to the wall switch. 1. Begin by moving the selector toggle on the wall switch to the “REMOTE” position. 2. Insert a straightened paper clip into the “PROGRAM” slot on the wall switch. 3. Press the internal “PROGRAM” button once and wait until you hear 3 beeps from the wall switch. 4. Press the ON/OFF button of the remote unit. Once the wall unit beeps 3 times, the remote is pro- grammed. 5. The toggle on the wall switch must be kept in the “REMOTE” position in order to use the remote control unit. TO FIREPLACE Wall Switch and Remote Control Figure 29: Wall switch - battery side. Wall Switch to IFC Communication Cable Continuity Check It is important that the continuity of the individual wires encased within the communication cable be checked before the cable is plugged into both the wall switch and the IFC Module. This will ensure that the cable is in good condition before the cable is walled in or otherwise covered up. Provided that no staples, screws or nails accidentally impale the cable during the walling up process, or any cables have otherwise been cut, the cable itself will be able to be ruled out as a possible cause should trouble shooting the wall switch be required. 16 TCWS54_D 150817-40 4/04/2019 5056.4252155D The NV / PV (Natural Vent / Power Vent) switch (Figure 30) on the interface board (Figure 26) is set according to which type of evacuating vent system is present. If the fireplace is vented with- out the assistance of a power vent, the switch must be set to “NV”. If using a power vent, “PV” must be selected. Follow the instructions pro- vided with the power vent kit for proper installa- tion. Figure 30: Vent mode selection switch. Selecting Natural Vent and Power Vent Modes 17TCWS54_D 021216-40 4/04/2019 5056.4252155D Figure 31: Complete communication wiring. TO HOME AUTOMATION SYSTEM NOTE: rDigital I/O must be connected to a dry contact relay. rAnalog flame and light input through 0 - 10 volt DC signal scaled as follows: Low = 1 volt High = 10 volts The home automation feature supplied with this fireplace is capable of controlling the flame and light on/off function with the use of a dry contact relay common to home automation systems. Furthermore, the flame and light level may be modu- lated from high to low using the 0 - 10 volt analog output avail- able on most home automation systems. Figure 31 shows the wire designations required to connect the fireplace to a home automation system. Home Automation NOTE: When a signal has been supplied by the home automation system, the fireplace control will repeat the signal every 2 hours or until a new command has been received. Leave the wall switch on the “Remote” setting when using home automation. Figure 32: Home automation wiring. 18 TCWS54_D 150817-40 4/04/2019 5056.4252155D Correct gas pressure requirement: Natural Gas Propane Min. Pressure 5.0" WC 12.5" WC (For purpose of input adjustment) Max. Pressure 13.9" WC 13.9" WC Manifold Pressure Maximum 3.5" WC 10" WC Minimum 1.6" WC 6.4" WC Note: To test the gas pressure, turn off the gas supply before removing the plug from the supply pressure test port or manifold pressure test port. Caution: The gas line should be installed by a qualified service person in accordance with all building codes. This section is intended as a guide for qualified technicians installing this appliance. Consult local and / or national building codes before proceeding. Gas supply line access holes are located at the top and left sides of the Control Box. Gas valve inlet accepts a 3/8" N.P.T. fitting. Correct gas line diameter must be used to assure proper operation and pressure. NOTE: This fireplace has an input rate of 54,900 BTU/HR on both Natural Gas and Propane. It is essential that a union or flanged connection be installed just upstream of the valve and inside the control compart- ment to allow for repair or replacement of the gas valve. NOTE: A sediment trap, as per national fuel gas code, must be installed in the gas supply line no more than 6 feet from the gas control valve to minimize the possibility of any loose scale or dirt within the gas supply line from entering the control valve. DO NOT HARD PIPE GAS LINE TO VALVE. A method of disconnecting the valve from the gas line such as a union or flare fitting must be provided to allow for repair or replacement of the gas valve. Check local codes for additional requirements. 1. Connect the gas supply to the valve (Figure 26). 2. Turn on the gas supply and check that all connections are tight and leak free. WARNING: The access panel including gasket must be reinstalled after conversion/installation or servicing has been completed. Failure to do so will cause overheating and premature failure of the control system. Verify gas pressures with the fireplace lit and on the highest setting. Please refer to the Burner Installation Manual for gas pressure testing procedure. SUPPLY PRESSURE MANIFOLD PRESSURE Figure 33: Test ports. 19TCWS54_D 021216-40 Gas Supply Gas Pressure Check 4/04/2019 5056.4252155D This fireplace can only be wall terminated using the TCVT. PV1.25 or TCVT.PV7.110 power vent kit. Please see the instructions supplied with the kit for installation details. Before installing venting for this unit, the installer should read these instructions to insure that the proper vent configuration has been selected. Use only Town and Country Termination kits #: TCVT.RTA - Roof Termination Kit For vent system components approved for use with the Town and Country Fireplace, See “Vent System Components” on page 20. Various combinations of vent runs may be used. See “Figure 36: Roof venting chart.” on page 22 for details. For optimum performance and flame appearance, keep the vent length to a minimum and limit the number of elbows. Connections between each vent system component must be tightly joined, secured with sheet metal screws and sealed with provided high temperature self adhesive tape. VENT SUPPORTS: A minimum of 1 support every 4’ must be used. NOTE: Optional Power Vents (TCVT.PVI.25, TCVT.PV7.110 & TCVT.PVCV) require different venting. Please refer to Power Vent manuals. CAUTION: UNDER NO CONDITION SHOULD COMBUSTIBLE MATERIAL BE CLOSER THAN 1 3/4 INCHES FROM THE TOP AND 1 3/4 INCHES FROM THE SIDES OF A HORIZONTAL SECTION AND 1 3/4 INCHES FROM THE VERTICAL SECTIONS OF THE VENT PIPE. Vent System Components Town & Country 12" Pipe Length ..................................................... TCVT.811X12 18" Pipe Length ..................................................... TCVT.811X18 24" Pipe Length ..................................................... TCVT.811X24 48" Pipe Length ..................................................... TCVT.811X48 12" Adjustable Pipe Length .............................TCVT.811X12ADJ 45° Elbow ..........................................................TCVT.811XLB45 Wall/Offset Support .............................................. TCVT.811XOS *A minimum of 1 support every 4’ must be used.* Roof Termination Kit ....................................................TCVT.RTA Wall Shield/Ceiling Firestop .................................... TCVT.THIMA Roof Flashing, Adjustable .................................TCVT.811FLADJ Roof Flashing, Flat .............................................TCVT.811FLFLT Roof Flashing, Steep .........................................TCVT.811FLSTP or any flashing that fits 11" pipe 20 TCWS54_D 150817-40 Venting Wall Termination Venting 4/04/2019 5056.4252155D Vent Pipe: 1. Install the first section of vent pipe into the collar on top of the fireplace. Secure in place with screws and seal with approved "High Temperature" self-adhesive aluminium tape provided. 2. Continue adding vent pipe lengths up and through the firestop(s) and through the roof. The vent pipe must extend at least 12” above the roof. Vent pipe may need to extend fur- ther depending on the roof pitch. For precise lengths, See “Roof Pitch Table” on page 25. Seal the vent pipe as per "Vent Pipe Sealant" section. Roof Support Bracket: Slip the roof support bracket down over the vent pipe. Rotate the 90° brackets to accommodate roof pitch. Attach the brackets to the roof joists with nails or building screws. Tighten the band around the vent pipe and secure in place with screws. Ceiling Opening: 1. Determine the exact position of the fireplace so that the vent pipe is cen- tered (if possible) between two building framing members. Lay out the vent system path, minimizing the number of elbows and length of vent. Consult your local building codes prior to proceeding. 2. Cut and frame a 14 1/2" opening in the floor, ceiling or roof where the vent system will pass. Size of the opening in the roof may need to be increased as the pitch of the roof increases. Avoid cutting rafters. Ceiling Firestop: Where a vent pipe passes through a floor or ceiling, a ceiling firestop (TCVT. THIMA) must be used to retain insulation and maintain proper clearances. From below, push the ceiling firestop through the opening and secure in place. If the firestop is used to penetrate a floor, the outer shield may be trimmed in length. If the firestop penetrates into an attic, leave the shield full length to keep insulation away from the vent pipe. Additionally, after the vent pipe is in place, install a storm collar on top of the shield. This will prevent loose insulation from falling into the area between the vent pipe and the shield. Size of the opening will have to increase with the pitch of the roof to ensure a 1 3/4" inch air space clearance between vent pipe and combustibles. Roof Pitch A B 0/12 14 1/2" 7 1/4" 4/12 16 1/2" 8 3/4" 6/12 18" 10" 8/12 19 3/4" 11" 12/12 24" 13 3/4" Roof Termination Venting 14 1/2” A B Figure 34: Roof opening frame. VENT PIPE ROOF SUPPORT BRACKET Figure 35: Roof support bracket. 21TCWS54_D 021216-40 4/04/2019 5056.4252155D MINIMUM VENT HEIGHT Various combinations of vent runs may be used. Refer to Figure 36 for details. For optimum perfor- mance and flame appearance, keep the vent length to a minimum and limit the number of elbows. Connections between each vent system component must be tightly joined, secured with sheet metal screws and sealed. CAUTION: Under no condition should combustible material be closer than 1 3/4 inches from any part of the vent pipe. Only 45º elbows can be used in this vent system. Maximum number of elbows is 2. Roof Termination Venting Chart This fireplace can be roof terminated using either the TCVT. PVCV power vent kit or the TCVT.RTA direct vent kit. Please see the instructions supplied with the kit forinstallation details. 20' 10' 8' 6 40' MAX. 4' 2' 48' 4' MAX. ' 18” MIN BEFORE ELBOW Figure 36: Roof venting chart. 22 TCWS54_D 150817-40 4/04/2019 5056.4252155D Figure 37: Roof vent terminal. Roof Vent Terminal: 1. Place the roof flashing over top of the vent pipe and seal it to the roof using the methods and materials appropriate for the type of roof on the building. Shingle roof example shown (Figure 37). 2. Place the storm collar down over the vent pipe until it is level. Tighten storm collar for a snug fit. Apply a thick horizontal ring of mastic around the pipe at top of the storm collar. 3. Lower the roof vent terminal cap over the vent pipe and secure in place with screws provided. Seal screw heads and joint with caulking to prevent any moisture entering the venting system. VERTICAL TERMINATION CAP FLASHING STORM COLLAR MASTIC NOTE: ADJUSTABLE FOR VARIOUS ROOF PITCHES, FROM FLAT ROOF TO 12/12 PITCH ROOF. VENT PIPE 23TCWS54_D 021216-40 4/04/2019 5056.4252155D A= *12 inches (30 cm) min. Clearances above grade, veranda, porch, deck, or balcony B= *12 inches (30 cm) min. Clearance to window or door that may be opened C= 12 inches (30 cm) min. Clearance to permanently closed window recommended to prevent condensation on window D= 30 inches (76 cm) min. Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (60 cm) from the edge of the terminal E= 30 inches (76 cm) min. Clearance to unventilated soffit F= 6 inches (15 cm) min. Clearance to outside corner G= 6 inches (15 cm) min. Clearance to inside corner H= 3 feet (90 cm) min. *Not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from the center-line of the regulator I= *3 feet (90 cm) min. Clearance to service regulator vent outlet J= *12 inches (30 cm) min. Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance K= *6 feet (1.8 m) min. Clearance to a mechanical air supply inlet L= *7 feet (2.1 m) min. ^ Clearance above paved side-walk or a paved driveway located on public property M= **30 inches (76 cm) min Clearance under veranda, porch, deck, or balcony ^ a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor* * as specified in CGA B149 Installation Codes, Note: local Codes or Regulation may require different clearances * for U.S.A. Installations follow the current National Fuel Gas Code, ANSI Z223.1 M K I AV G G H AJ V G A B C A V V AV B FBL V E V V V D FIXED CLOSED FIXED CLOSED OPEN- ABLEOPEN- ABLE AIR SUPPLY INLETVENT TERMINAL GAS METERAREA WHERE TERMINAL IS NOT PERMITTED B B Figure 38: Vent terminal minimum clearances. 24 TCWS54_D 150817-40 Vent Terminal Minimum Clearances 4/04/2019 5056.4252155D See Roof Pitch Table Adjacent Structures or Fence 48” (122 cm) 36” (91.5 cm) 24” (61 cm) Figure 39: Vent roof clearance. Figure 40: TCWS54D Sealing vent joints. ^ a vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves both dwellings* ** only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2 sides beneath the floor* * as specified in CGA B149 Installation Codes, Note: local Codes or Regulation may require different clearances * for U.S.A. Installations follow the current National Fuel Gas Code, ANSI Z223.1 VENT TERMINAL MINIMUM CLEARANCES TO ADJACENT STRUCTURES Minimum clearances to the vent terminal must be maintained as shown in Figure 38 and Figure 39. Measure clearances to the nearest edge of termination hood. NOTE: Vent terminal must not be recessed NOTE: LOCAL CODES OR REGULATIONS MAY REQUIRE DIFFERENT CLEARANCES. (minimum) ft m Flat to 6/12 1.00 0.30 Over 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 1.50 0.46 Over 8/12 to 9/12 2.00 0.61 Over 9/12 to 10/12 2.50 0.76 Over 10/12 to 11/12 3.25 0.99 Over 11/12 to 12/12 4.00 1.22 Roof Pitch Table All outer joints of the vent pipe must be sealed with the approved "High Temperature" self-adhesive alumin- ium tape provided. Wrap the tape completely around the joint and press firmly in place. Inner pipe does not need to be sealed. APPROVED “HIGH TEMP.” SELF-ADHESIVE TAPE (SUPPLIED) VENT PIPE 25TCWS54_D 021216-40 Vent Terminal Clearance Vent Pipe Sealant 4/04/2019 5056.4252155D Figure 42: Vent restrictor. FULLY OPEN 4“ OPEN 2“ OPEN 1“ OPEN 10’ 20’ 30’ 40’ 48’ 0 1 2 3 4 Figure 41: Restrictor rise and run chart. VENT RESTRICTOR OPENING The vent restrictor is located on the underside of the firebox top. The unit leaves the factory with the vent restrictor open. The restrictor is built into the appliance for secondary air flow adjustment. Adjustment enables tuning the airflow for optimum flame appearance and perfor- mance for a wide variety of vent configurations. Setting: rDetermine the vent height. rDetermine the vent horizontal length. rFrom the chart determine the restrictor position. Refer to the chart (Figure 41) for the correct position of restrictor for the vent configuration of your installation. Restrictor positions are based upon lab tests. The ideal position may vary slightly with installation. Restrictor position is too closed if the flame has the following characteristics: rFlame is excessively tall and lifting. rFlame lacks movement. rFlame soots. Restrictor position is too open if the flame has the following characteristics: rFlame height is low. rFlame has excessive movement. To adjust the restrictor: rLoosen the screw holding the restrictor. rMove the restrictor to its intended opening. rRe-tighten the screw. WALL AND ROOF TERMINATION RESTRICTOR POSITION CAUTION: The vent restrictor must be fully open when using the power vent 26 TCWS54_D 150817-40 Vent Restrictor Adjustment 4/04/2019 5056.4252155D VERTICAL TERMINATION CAP TCVT.9365 ROOF SUPPORT BRACKET TCVT.93915 STORM COLLAR TC42.90665 CEILING FIRESTOP TCVT.THIMA Roof Termination Kit 16 1/2" 9" Figure 43: Roof terminator kit. 27TCWS54_D 021216-40 4/04/2019 5056.4252155D 4 5 ° 11" 9 1/2"10 15/16" 10 5/16" 15 7/8" 7/16" 1 5/16" 8 5/16" 13 13/16"12 9/16" 13 1/8" * 11 1/8" TCVT.811X12ADJ TCVT.811XLB45 TCVT.811XLB90 TCVT.811X _ _ Figure 44: Vent pipe dimensions. 12" PIPE ..........10 1/4" 18" PIPE ..........16 1/4" 24" PIPE ..........22 1/4" 48" PIPE ..........46 1/4" 28 TCWS54_D 150817-40 Vent Pipe Dimensions 4/04/2019 5056.4252155D 1 1/4” 11 3/8” 10 7/8” B A C 1 1/4” 1 1/4” 16 1/16” 6 1/8” B A C 1 1/4” 20" 1 1/4”18 3/4”B A 20” 1 1/4” Figure 45: Vent offsets. 29TCWS54_D 021216-40 Vent Offset Chart ADDING AN ADJUSTABLE SECTION TO PIPE WILL INCREASE OFFSET BY 2 1/8" TO 6 3/4" A B C 12" PIPE 18 5/8" 18" 18" PIPE 22 7/8" 22 3/8" 24" PIPE 27 1/8" 26 1/2" 48" PIPE 44 1/16" 43 1/2" ADDING AN ADJUSTABLE SECTION TO PIPE WILL INCREASE OFFSET BY 2 1/8" TO 6 3/4" A B C 12" PIPE 13 7/16" 23 1/4" 18" PIPE 17 9/16" 27 5/8" 24" PIPE 21 7/8" 31 3/4" 48" PIPE 38 3/4" 44 7/8" A B 12" PIPE 29" 18" PIPE 35" 24" PIPE 41" 48" PIPE 65" ADDING AN ADJUSTABLE SECTION TO PIPE WILL INCREASE OFFSET BY 3" TO 9 1/2" 4/04/2019 5056.4252155D Seat tab location Back panel Figure 46: Right seat tab. Seat tab location Left side panel Back panel Figure 47: Left seat tab location. Front bottom panel Figure 48: Front panel. WIDE EDGE FACING THE FRONT OF THE FIREPLACE Figure 49: Front panel - side view 1. Insert the back panel (Figure 46) into the firebox by tilting the panel and rest the panel on the seat tabs at the back of the firebox. NOTE: Seat tabs can be lowered if the rear panel is tight. NOTE: Centering tabs on the panel should be located at the outside of the seat tabs. 2. While supporting the back panel insert the left side panel (Figure 47) into the firebox. Position the top of the panel against the side of the unit, inserting the top panel tab into the slot at the top of the side panel and slide the bottom into position. NOTE: Notch at bottom of side panel faces to front of unit. 3. Repeat step 4 for the other side panel. NOTE: Install burner now. 4. Place the front bottom panel (Figure 48) on the front lip of the firebox, wide flange facing the front (Figure 49). (Proceed to step #5 if you are installing a TCWS.54NG03.C2 Black Diamond burner with this unit.) 5. Place the other bottom panel piece at the rear of the firebox with the wide flange facing to the rear against the back panel. Installation note: The panel set comes with an upper panel. When installing firebox panels into a “C” series fireplace, use this upper panel. When installing firebox panels into a “D” series fireplace, do not install the upper panel as this panel will obscure the LED light fixtures. Discard this panel instead. Installing firebox panels into a “D” series fireplace. 30 TCWS54_D 150817-40 Firebox Panels Installation 4/04/2019 5056.4252155D Figure 50: Finishing touch trim kit. 1. Place two smaller magnets on back of each side rail. 2. Place two larger magnets on back of the top and bottom rails. 3. Attach the side rails. Even the ends up with the door frame. 4. Attach the top and bottom rails and adjust so mitres are even at the corners. 5. Place TC magnetic logo in bottom right corner. LARGER MAGNETS TOP OR BOTTOM RAIL SIDE RAILS 31TCWS54_D 021216-40 Finishing Touch Trim Kit Instructions 4/04/2019 5056.4252155D Linking Remote Handset to the Fireplace Town & Country Fireplaces can be operated remotely by using the remote handset that came with the fire- place, and by using a BlueTooth® enabled apple mobile device and the “TC Fire” app which can be down- loaded free from the Apple® app store. For linking to the fireplace using a BlueTooth® enabled apple mobile device, refer to the user manual that came with this fireplace. For linking the remote handset that came with this fireplace, complete the following two steps: Step 1: Procedure for linking / pairing wall switch to fireplace 1. Set the wall switch selector to the “Remote” setting. 2. Press and hold Program button (Figure 51) on the wall switch for up to 10 seconds. Use a straight- ened paper clip to access the button. 3. The wall switch will beep 5 times. Release the button following the beeps. 4. The fireplace will beep 3 times repeated by another 3 beeps. 5. The fireplace and wall switch are now linked/paired. If there is cross communication with another nearby fireplace causing the other fireplace to activate instead of the intended fireplace, repeat above procedure to automatically switch to another one of three available channels. Figure 51: Town and Country wall switch. PROGRAM BUTTON 32 TCWS54_D 150817-40 4/04/2019 5056.4252155D Step 2: Procedure for linking / pairing the wall switch to remote handset 1. Press and release Program button on the wall switch once (Figure 51). 2. You will hear 3 beeps from the wall switch. 3. Press and release the on/off button (Figure 52) on the remote handset (within 60 sec.) 4. The wall switch will beep 3 times. 5. The remote handset is now linked/paired to the wall switch and is ready to activate the fireplace. ON /OFF Figure 52: Remote handset. 33TCWS54_D 021216-40 4/04/2019 5056.4252155D Figure 53: Pilot assembly. CAUTION: Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the fireplace and its venting should be inspected at least once a year by a qualified service person. Glass Panel: Warning: Do not operate fireplace with glass panel removed, cracked or broken. Replacement of the glass panel should be done by a licensed or qualified service person. Do not strike or otherwise impact the glass in anyway that may cause it to break. If the glass becomes cracked or broken it must be replaced before using the fireplace. Replacement glass can be obtained from your nearest Town & Country FireplacesTM dealer. The size required is 52" x 16" x 5mm. Use ceramic glass only. Do not substitute with any other type. To remove broken glass, remove window frame as noted in "Window Frame Removal" section. Unclip the Glass Retainer Clips located at the top and sides of the Window Frame. Pull the top edge of the glass out of the frame first, then lift it up and out of the bottom edge. Install the new piece of glass with the gasket into the frame so that the thicker bead of gasket faces the fireplace. Re-install glass retaining clips. Annual Inspection: a) Remove glass panel and pebble assemblies. Inspect pebble and burner assemblies for soot buildup. If excessive buildup of soot is present, have a qualified service person inspect and adjust unit for proper combustion. Clean logs and burner with a brush or vacuum cleaner, paying close attention to burner ports. b) Check the pilot system for proper flame size and operation. Clean pilot free of soot, dust or any other deposits. (See Fig. #67) c) Check that the vent pipe and vent terminal are open and free from blockage or debris. If the venting is disassembled for cleaning, it must be properly assembled and re-sealed. Refer to VENTING section for proper procedure. d) Check glass panel gasket, replace if necessary. It is important that the glass seal be maintained in good condition. e) Check and replace batteries as needed. Note: The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids. Periodically: a) Viewing glass may be cleaned as necessary with fireplace glass cleaner. b) Exterior finish may be cleaned with mild soap and water. CAUTION: Do not use abrasive cleaners on glass or any other part of the fireplace. Do not clean glass when hot. PILOT FLAMEFLAME SENSOR ELECTRODE PILOT 34 TCWS54_D 150817-40 Maintenance 4/04/2019 5056.4252155D (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM DESCRIPTION PART NO. #1 TCWS BODY ASSEMBLY ..................................TCWS.54D #2 GLASS ASSEMBLY (c/w gasket) ............. GLAS.2062ASSY #3 FRAMING KIT ................................................TCWS.8267-B #4 PANEL SETS BLACK PORCELAIN ........................................TCPN.775.C BROWN PORCELAIN ..................................TCPN.775CB.C COPPER ..................................................TCPN.WS54CU.C TITANIUM ..................................................TCPN.WS54TI.C ITEM DESCRIPTION PART NO. *#5 FINISHING TOUCH TRIM KIT .......................TCWS.8265-A #6 ORIFICE (2pcs) .................................................... 5022.78-A #7 MAIN GAS SUPPLY TUBES (3pcs) .......................5019.223 #8 BURNER SUPPORT .................................................9498-B #9 PILOT ASSEMBLY ......................................TCRP.5005025F #10 1/2” TEE ................................................................5019.013 *NOT SHOWN KIT CONTENTS: #1...........TCWS BODY ASSEMBLY 1a SPRING LATCH ASSEMBLY (2) 1b CONTROL BOX 1c LED LIGHT ASSEMBLY #4..........PANEL SETS 4a PANEL, FRONT BASE x2 4b PANEL, LEFT SIDE 4c PANEL, UPPER 4d PANEL, REAR 4e PANEL, RIGHT SIDE #2..........GLASS ASSEMBLY (c/w gasket) #3......... FRAMING KIT 3a STEEL STUDS #1 #2 #3 #4 VALVE CONTROL SYSTEM - See page 363A 4A 4B 4C 4E 4D 1A 1B 6 7 8 10 9 1C 35TCWS54_D 021216-40 TCWS.54D Replacement Parts 4/04/2019 5056.4252155D 1i 1g 1j 1a 1h 1f 2a 2d 2e 2b 2c #2 #1 1c 1b 3 4 1e 1d 2f (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM DESCRIPTION PART NO. #4 TEST FITTING .......................................................5019.104 #5 WALL SWITCH ASSEMBLY KIT .........................TCRP.WSA #6 REMOTE TRANSMITTER ...............................TCRP.500307 KIT CONTENTS: Replacement Parts – Valve Control System #2 BULKHEAD ASSEMBLY KIT 2a INLET PLATE 2b INLET PLATE GASKET 2c ELEC BULKHEAD GASKET 2d 1/2" BULKHEAD FITTING 2e 1/4" BULKHEAD FITTING 2f ELEC BULKHEAD FITTING #3 CABLE COMMUNICATION KIT #4 TEST FITTING #5 WALL SWITCH ASSEMBLY KIT (not shown) #6 REMOTE TRANSMITTER (not shown) ITEM DESCRIPTION PART NO. #1 CONTROL ASSEMBLY KIT ..........................TCCV.95755-B #2 BULKHEAD ASSEMBLY KIT ..............................TCRP.8133 #3 COMMUNICATION CABLE KIT ........................... 5062.98-A #1 CONTROL ASSEMBLY KIT 1a VALVE c/w FITTINGS 1b 1/4” FLEX TUBE 1c 1/2” FLEX TUBE 1d CONTROL MOUNTING BRACKET 1e IGNITION MODULE 1f WIRING HARNESS 1g TRANSFORMER 1h PRESSURE TEST ASSEMBLY 1i REGULATOR BOARD 1j PRESSURE SWITCH 36 TCWS54_D 150817-40 4/04/2019 5056.4252155D37TCWS54_D 021216-40 Wiring Diagram 4/04/2019 5056.4252155D Figure 54: Front panel base.Figure 55: Securing tab. Figure 56: Removing the side panel.Figure 57: Access panel. 1. Remove front panel base (Figure 54). Also remove rear panel base if Black Diamond Burner is fitted. 2. Push up on the heat shield, at the right end of the unit near the middle, enough to clear the securing tab (Figure 55). FRONT PANEL BASE 3. Pull the top of the right panel toward the center of the unit using caution not to scratch the back panel (Figure 56). 4. Once the right panel is tilted inwards it can be lifted clear of the burner tray and removed. NOTE: The right hand side rock cluster may need to be removed to prevent damage while working through the access hole. Covering the sand with paper or cardboard will also minimize disturbance during the servicing process. 5. The access panel is now visible (Figure 57). 6. Reassemble in reverse order. WARNING: The control box shield, access panel and gasket must be replaced. Failure to do so will overheat and cause premature failure of the control. 38 TCWS54_D 150817-40 Quick Panel Removal for Valve Service 4/04/2019 5056.4252155D DATE OF MANUFACTURE JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2014 2015 2016 Optional components/ Éléments facultatifs: Powervent Kit/ kit de ventilation mécanique TCVT.PVI.25, TCVT.PV7.110, TCVT.PVCV Blower electrical rating: 115v, 60hz, 1.1 A / Normes electriques du ventilateur: 115v, 60hz, 1.1 A This appliance equipped for altitudes 0 - 4500 ft. (0 - 1372 m) / Cet unité est conçu pour des altitudes variant entre 0 - 4500 pieds (0 - 1372 m). In Canada, also certified for installation in a bedroom or a bedsitting room / Aussi certifié pour installation dans une chambre à coucher ou une salle de séjour. This appliance must be installed in accordance with local codes, if any; if none, follow the current CAN/CGA-B149 (Canada), or ANSI Z223.1 (USA) Installation Codes. Installer l’appareil selon les codes ou règlements locaux, ou, en l’absence de tels règlements, selon les codes d’installation CAN/CGA-B149 (Canada), or ANSI Z223.1 (USA) en vigeur. MANUFACTURED (MOBILE) HOME: This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owners manual for details. FABRIQUEZ (MOBILE) MAISON: Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique et peut être installé dans une maison préfabriquée (mobile) installée à demeure si les règlements locaux le permettent. Voir la notice du propriétaire pour plus de détails. Cet appareil ne peut être converti à d’autres gaz sauf si une trousse de conversion certifiée est utilisée. Install in accordance with the current standard Mobile Homes,CAN/CSA Z240 MH (in CANADA), and the Manufacturer’s Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, (in the U.S.A.). Cet appareil diot être installé conformemént aux exigences de la norme CAN/CSA Z240 MH en vigueur de l’ACNOR, Installations de gaz dans les Constructions Mobiles. FOR USE WITH THE GLASS AND SCREEN BARRIER CERTIFIED WITH THE APPLIANCE ONLY / POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIÉES AVEC L’APPAREIL MINIMUM CLEARANCES TO COMBUSTIBLES / CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Left and Right side are determined when facing the front of the appliance. / Les côtés droit et gauche se déterminent en se mettant devant l’appareil et en lui faisant face. Top, Back and Side Standoffs / Sommet, Arrière et Côté Butée 0 in./ 0 po. (0 mm) Sidewall to Appliance / Du mur latéral a l’appareil 4 in./ 4 po. (102 mm) Ceiling to Appliance / Plafond a l’appareil 24 in./ 24 po. (610 mm) Mantel to Appliance / Du manteau al’appareil *9 in./ 9 po. (229 mm) Maximum Mantel Extension / Allongement maximum du manteau *12 in./ 12 po. (305 mm) *See Installation Manual for more detail / Voyez des Directive de l’Installation pour plus détaux. Mantel Supports / Supports du manteau 4 in./ 4 po. (102 mm) Vent Pipe / Déchargez le Tuyau 1.75 in./ 1.75 po. (45 mm) FOR USE WITH/ NATURAL GAS/ LP GAS/EN CASE D’EMPLOI AVEC: DU GAZ NATUREL DU GAZ LP Minimum supply pressure / Pression minimum d’alimentation: 5.0 in/wc / 5.0 po/c.e. 12.5 in/wc / 12.5 po/c.e. (For the purpose of input adjustment / dans le but de régler l’alimenation) (1.25 kPa) (3.11 kPa) Maximum supply pressure / Pression maximum d’alimentation: 13.9 in/wc / 13.9 po/c.e. 13.9 in/wc / 13.9 po/c.e. (3.45 kPa) (3.45 kPa) Manifold pressure / Pression de la tuyauterie: Maximum 3.5 in/wc / 3.5 po/c.e. 10.0 in/wc / 10.0 po/c.e. (0.95 kPa) (2.74 kPa) Orifice Size / Diametre de l’injectuer: (2.82 mm) 2X (1.70 mm) 2X Input BTU/hr (kW) / Entree BTU/h (kW): Max.: 54,900 (16.0) Max.: 54,900 (16.0) Min.: 38,500 (11.3) Min.: 45,000 (13.2) Pacific Energy Fireplace Products Ltd. Duncan, British Columbia, Canada 709 MADE IN CANADA FABRIQUE AU CANADA This Appliance is Equipped For Use With / Cet Appareil est Équipé Pour Utilise Avec : NATURAL GAS GAZ NATUREL Certified for / Certifié pour Canada and U.S.A. 050814 5050.7204D 1-TCWS54-D VENTED GAS FIREPLACE - NOT FOR USE WITH SOLID FUEL FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE ANSI Z21.50-2014 / CSA 2.22-2014 Vented Gas Fireplaces CAN/CGA 2.17-M91 Gas-Fired Appliance For Use At High Altitudes. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information, consult a qualified installer, service agency or the gas supplier. AVERTISSEMENT: Une installation, un réglage, une modification, une réparation ou un entretien mal effectué peut causer des dommages matériels ou des blessures. Voir la notice de l’utilisateur qui accompgne l’appareil. Pour de l’aide ou des renseignements supplémentaires, consultez un installateur, un technicien agréé ou le fournisseur de gaz. LP-GAS LP GAZ MODEL/ MODELE: TCWS54 SERIES/ SERIE: D NOTE: The Rating Label is located on a plate found in a slot between the left hand side lintel and the left hand side window frame. This plate is attached to the lintel with a cable. Rating Label 39TCWS54_D 021216-40 4/04/2019 © 2017 Copyright Pacific Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright law. For technical support, please contact your retailer. Web site: www.townandcountryfireplaces.net 2975 Allenby Rd., Duncan, BC V9L 6V8 Printed in Canada 4/04/2019 The Architectural SeriesINTRODUCING BY TOWN & COUNTRY Go ahead – fire up your imagination. TOWN & COUNTRY LUXURY FIREPLACES www.townandcountryfireplaces.com 4/04/2019 CONFIGURATIONS Single Pane Corner Right Panorama Peninsula Right See-Thru Peninsula LeftCorner Left • 16,000 BTU/ft • Direct ignition • Combustible finish to glass edge • Load bearing up to 1” marble • No metal supports in view • Full colour LED under- lit burner • “Shadow-Free” glass burner • No pilot assembly in viewing area • Honeywell 24-volt valve • Smart Home capable • Electronic heat exchanger • Length: 3ft - 8ft • Glass Height: 16” or 24” DISTINGUISHING FEATURES CONFIGURATIONS Introducing The Architectural Series by Town & Country, North America’s most sophisticated luxury fireplace. Designed for visual performance, The Architectural Series features a dramatic flame powered by 16,000 BTUs per foot combined with a custom firebox airflow control system to allow fine art or the ultimate TV to hang directly above the viewing area. Narrow depth cool touch glass makes the flame the focal point while loadbearing construction offers the interior designer complete flexibility. • 3 ft. – 8 ft. burner lengths in 1 ft. increments • cool touch glass in 2 heights • six distinctive configurations • one continuous grand flame For more information, email: launch@townandcountryfireplaces.com townandcountryfireplaces.com Pr i n t e d i n C a n a d a TO W N . A R S E R I E S The Architectural Series 4/04/2019