City Series CV40E Gas Fireplace
Model CV40E-NG11 CV40E-LP11
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 11” W.C. (2.73 kPa)
Manifold Pressure - High 3.8” W.C. (0.94 kPa) 10.5” W.C. (2.62 kPa)
Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 2.9” W.C. (0.72 kPa)
Orifice Size -Altitude 0-4500 ft.#42 DMS #53 DMS
Minimum Input
Altitude 0-4500 ft. (0-1372m)
15,500 BTU/h
(4.54 kW)
15,500 BTU/h
(4.54 kW)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
28,500 BTU/h
(8.33 kW)
28,500 BTU/h
(8.33 kW)
Vent Sizing 4” Inner / 6-5/8” Outer 4” Inner / 6-5/8” Outer
CSA P.4.1 55.23%56.06%
33
7 16
"
84
9
m
m
43"
1091mm
25
9 16
"
64
8
m
m
46 14 “
1175mm
7
1 4
"
18
3
m
m
40
1016mm
Ø 6
34 "
171mm
Ø 4"102mm
11
7 16
"
29
1
m
m
21 78 "
556mm
18 1116 "
475mm
17 1116 "
449mm
15
1 16
"
38
2
m
m
7
7 8
"
20
0
m
m
37
3 8
"
94
9
m
m
34
5 8
"
87
9
m
m
10
1 2
"
26
7
m
m
"
"
07/31/2019
City Series
Caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
WARNINGFire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
CLEARANCES CV40E
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance
that this fireplace and vent system be installed only in accordance with these instructions.
Clearance: single sided Dimension Measured From:
A: Mantel Height (min.)**Top of Fireplace Opening
B1: From Floor Min. 0" Bottom of Fireplace Opening
B2: Opening Height 15-1/16" (383mm) Bottom/Top of Fireplace Opening
C: Sidewall (on one side)8-1/2" (216mm) Side of Fireplace Opening
D: Mantel Depth (max.)**
E: Alcove Width 84" (2134mm) Sidewall to Sidewall (Minimum)
F: Alcove Depth 36" (914mm) Front to Unit (Maximum)
G: Ceiling
(in front of fireplace)
37-1/2" (953mm) Top of Fireplace Opening
H: Convection Air Outlet *Top of Enclosure
J: Convection Air Outlet Opening Offset 0-3" (76mm) Max. offset from top of chase enclosure
K: Chase Enclosure (Min.)63" (1600mm) From base of unit/floor
L: Clearance to Sprinkler Head (Min.)36" (914mm) Perpendicular from chase grill
Hearth 0"No hearth required
** See mantel clearances chart on the next page.
Flue Clearances to Combustibles
Horizontal - Top 3"
Horizontal - Side 2"
Horizontal - Bottom 2"
Vertical 2"
Passing through wall/
floor/ceiling - when
firestop is used.
1-1/2"
Alcove
E
F
D
A
C
B1
G
B2
J
H
K
The HeatWave Duct Kit has
different clearance and framing
requirements, check the HeatWave
manual for details.
*A minimum of 120 square
inches of open area, not
lower than 3" from top of
enclosure, required for all
installations
CV40E-11 Gas Fireplace
L
Chase grill
Sprinkler
Side view
07/31/2019
City Series
CV40E-11 Gas Fireplace
MANTEL CLEARANCES CV40E
Combustible mantel clearances from top of front facing
are shown in the diagram on the right.
MANTEL LEG CLEARANCES
Combustible mantel leg clearances as per diagram:
212 6 4810
0
14
9"
15-1/16”
10
20
26
Topof
Fireplace
Opening
12" (305mm)
1/2" Drywall, wood, wood panel, etc.
5-1/8"
To
Bottom of
Fireplace
Opening
12
"
4"
Allowable mantel
MANTEL LEG
leg projection
7"
8-1/2"
2"
CV40E
07/31/2019
City Series
FRAMING DIMENSIONS CV40E
NOTE: Framing may be constructed of combustible material (ie. 2 x 4)and does not require steel studs.
Framing
Dimensions Description CV40E
A Framing Height 37-3/8” (949mm)
B Framing Width 46-3/4" (1187mm)
C Framing Depth 19" (483mm)
D Minimum Height to Combustibles 63"(1600mm)
E Corner Wall Depth 55" (1396mm)
F Corner Facing Wall Width 77-3/4" (1974mm)
G Vent Centerline Height 56-1/4" (1429mm)
I Gas Connection Opening Height 2" (51mm)
J Gas Connection Height 4 " (106mm)
K Gas Connection Inset 13" (330mm)
L Gas Connection Opening Width 3-1/2" (89mm)
Note: A combined minimum of
120 square inches of open area
is required for the convection
air outlet to cool the enclosure.
Ensure clearances for Convection
Air Outlets are met.
See clearances CV40E (single
sided) in this manual as there
are different methods as to how
this can be achieved.
Note: This appliance must be
installed on a solid surface such
as a plywood floor which must
be the full width and depth of the
appliance.
Maximum material
dimensions 2" x 4" for
Header studs (installed
on edge and flat)
CV40E-11 Gas Fireplace
07/31/2019
City Series
VENTING INTRODUCTION
The CV40E uses the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer
liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing
warm room air up the chimney.
Note: These flue pipes must not be connected to any other appliance.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate
solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.
VENTING ARRANGEMENT FOR HORIZONTAL TERMINATIONS
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90o (two 45o elbows equal one 90o elbow).
Note: Must use optional rigid pipe adapter (Part# 510-994) when using Rigid Pipe Venting Systems.
•Maintain clearances to combustibles as listed in "Clearances" section
•Horizontal vent must be supported every 3 feet.
•Firestops are required at each floor level and whenever passing through a wall.
•A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
•Flex system can only be used up to 10 feet - otherwise rigid venting must be used.
VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 0.
Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 2 if required.
Note: For horizontal terminations the Regency Direct Vent Flex System may be used for installations with a maximum continuous vent
length of up to 10 feet. If longer runs are required, rigid pipe must be used.
56-1/4” (1429mm)
CV40E-11 Gas Fireplace
07/31/2019
City Series
CV40E-11 Gas Fireplace
HORIZONTAL TERMINATIONS
RIGID PIPE 4" X 6-5/8"
The diagrams below show examples of horizontal termination arrangements using one, two, or three 90o elbows (two 45o elbows equal one 90o elbow) .
1. A maximum of three 90
o elbows are permitted.
2. Minimum distance between elbows is 1 ft. (305mm).
•Maintain clearances to combustibles as listed in the "Clearances" section.
•Horizontal vent must be supported every 3 feet.
•Firestops are required at each floor level and whenever passing through a wall.
•Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems.
•A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
•Flex system can only be used up to 10 feet - otherwise rigid venting must be used.
HORIZONTAL VENTING WITH TWO (2) 90O ELBOWS
One 90o elbow = Two 45o elbows.
Option V H + H1
With these options,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90o elbows
is required.
A) 1' Min. 2' Max.
B) 2' Min. 4' Max.
C) 3' Min. 5' Max.
D) 4' Min. 6' Max.
E) 5' Min. 7' Max.
F) 6' Min. 8' Max.
Restrictor Set 0 - Factory Setting
HORIZONTAL VENTING WITH THREE (3) 90O ELBOWS
One 90o elbow = Two 45o elbows.
Option V H V + V1 H + H1
With these options,
max. total pipe
length is 30 feet with
min. of 12 feet total
vertical and max. 9
feet total horizontal.
Please note min. 1
foot between 90o
elbows is required.
A) 1' Min. 1' Max. 2' Min. 2' Max.
B) 1' Min. 2' Max. 3' Min. 3' Max.
C) 2' Min. 2' Max. 5' Min. 4' Max.
D) 3' Min. 2' Max. 7' Min. 5' Max.
E) 4' Min. 3’ Max. 9' Min. 6' Max.
F) 5' Min. 4' Max. 10' Min. 7' Max.
G) 6' Min. 5' Max. 11' Min. 8' Max.
H) 7' Min. 6' Max. 12' Min. 9' Max.
Restrictor Set 0 - Factory Setting
07/31/2019
City Series
VENTING ARRANGEMENT FOR VERTICAL TERMINATIONS
VERTICAL VENTING WITH STRAIGHT VERTICAL VENTING AND OR WITH A MAX. OF TWO (2) 90O ELBOWS (1 - 90O = 2 - 45O)
The shaded area in the diagram shows all allowable combinations
of straight vertical and offset to vertical terminations, using two
90o elbows, with Rigid Pipe Venting Systems.
Two 45o elbows equal to one 90o elbow.
• Vent must be supported at offsets.
•Minimum distance between elbows is 1 ft. (305mm).
•Maintain clearances to combustibles as listed in the
"Clearances" section.
•Horizontal vent must be supported every 3 feet.
•Firestops are required at each floor level and whenever
passing through a wall.
•Must use optional rigid pipe adaptor (Part# 510-994) when
using rigid pipe vent systems.
•Refer to the "Vent Restrictor Position" section for details on
how to change the vent restrictor from the factory setting
of Set 0 through to Set 3 if required.
Ma
x
i
m
u
m
:
3
7
f
t
.
(
1
1
.
2
m
)
Mi
n
i
m
u
m
8’
6
”
(
2
.
6
m
)
Mi
n
.
5
6
-
1
/
4
”
(1
4
2
9
m
m
)
Minimum length of pipe
between elbows 12” (305mm)
Ma
x
i
m
u
m
:
2
7
f
t
.
(
8
.
2
m
)
0
2
4
6
40
8
10
12
14
16
18
20
22
24
26
28
30
Ve
r
t
i
c
a
l
H
e
i
g
h
t
(
F
e
e
t
)
32
34
36
38
6 8
Horizontal (Feet)
20 4 10 12 16 1814 20
Vent Restrictor on Set 2
Vent Restrictor on Set 3
Vent Restrictor on Set 1
CV40E-11 Gas Fireplace
07/31/2019
City Series
VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8"
•Two 45o elbows equal to one 90o elbow. Maximum of six 45o elbows allowed.
•Vent must be supported at offsets.
•Minimum distance between elbows is 1 ft. (305mm).
•Maintain clearances to combustibles as listed in the "Clearances" section.
•Horizontal vent must be supported every 3 feet.
•Firestops are required at each floor level and whenever passing through a wall.
•Must use optional rigid pipe adaptor (Part# 510-994) when using rigid pipe vent systems.
Vertical Venting with Three (3) 90o Elbows
One 90o elbow = Two 45o elbows.
VH1H
V1
Option V H + H1 V + V1
With these options,
max. total pipe length
is 30 feet with min. of
10 feet total vertical
and max. 8 feet total
horizontal.
Please note min. 1
foot between 90o
elbows is required.
A) 1' Min. 2' Max 3' Min.
B) 2' Min. 3' Max 4' Min.
C) 3' Min. 4' Max 6' Min.
D) 4' Min. 5' Max 7' Min.
E) 5' Min. 6' Max 8' Min.
F) 6' Min. 7' Max 9' Min.
G) 7' Min. 8' Max 10' Min.
Lengths do not include elbow indicated
Restrictor Set 0 - Factory Setting
CV40E-11 Gas Fireplace
07/31/2019
City Series
TV RECESSED INTO WALL
MAXIMUM TV RECESS TV FLUSH WITH HEARTH
Max. 2 x 4 stud
Max. 2 x 4 stud
CB40 Typical Installs
MAXIMUM TV RECESS FLUSH TV WITH HEARTH
5/8”4 maximum TV recess
using 1/2” drywall Flush wall TV recess using 1/2" drywall
Max 36”
Hearth
1/8Max 5 ”
Mantle
5/8Max 4 ”
TV recess with drywall
up against unit
Max 3”
To Top of Enclosure
2120in min
Chase vent opening
Header Stud
15
.
5
”
mi
n
12
”
m
i
n
Screws must not
penetrate unit more
than 1/2” .
Adhere to “No Screw”
zones painted on unit.
Glue can be used
as an alternative.
Max 3”
To Top of Enclosure
2120in min
Chase vent opening
Max. 2 x 4 stud
Max. 2 x 4 stud
CB40 Typical Installs
MAXIMUM TV RECESS FLUSH TV WITH HEARTH
5/8”4 maximum TV recess
using 1/2” drywall Flush wall TV recess using 1/2" drywall
Max 36”
Hearth
1/8Max 5 ”
Mantle
5/8Max 4 ”
TV recess with drywall
up against unit
Max 3”
To Top of Enclosure
2120in min
Chase vent opening
Header Stud
15
.
5
”
mi
n
12
”
m
i
n
Screws must not
penetrate unit more
than 1/2” .
Adhere to “No Screw”
zones painted on unit.
Glue can be used
as an alternative.
Max 3”
To Top of Enclosure
2120in min
Chase vent opening
CB40E shown CB40E shown
CV40E-11 Gas Fireplace
07/31/2019