HomeMy WebLinkAboutFile Documents.555 E Durant Ave.0025.2019 (36).ACBKPierce + Frye Architects  Vail and San Francisco 970.949.0899  www.PierceFrye.com November 25, 2019 City of Aspen Community Development 130 S Galena St Aspen, CO 81611 Attn: Bonnie Muhigirwa, Plans Examiner RE: Gorsuch Lockers 555 E. Durant, Unit C-2E Building Permit Number: 0064.2019.ACBK Dear Ms. Muhigirwa, Please find below responses to Building Comments sent in your email, dated November 21, 2019. The comments reference revised architectural drawings and other affected documents. A link to these documents will be provided in an email with this letter. The following summarizes our responses to your comments: Building Comments: 1. One drinking fountain is required per 2015 IPC Table 403.1. The previously approved plans had a beverage counter to meet this requirement, but that has been eliminated. An accessible drinking fountain or water cooler needs to be provided. See 1-A1, Accessibility Plan and 2-A2, Floor Plan - New – A water cooler has been added near the “fireplace”. 2. This configuration of single user toilet stalls with common sinks does not meet the requirement of the IPC. Separate plumbing facilities are required for each gender per 2015 IPC 403.2. In employee and public lavatories, the required lavatory shall be located in the same room as the water closet per 2015 IPC 405.3.2. See 1-A1, Accessibility Plan and 2-A2, Floor Plan - New – A lavatory has been added in each toilet room and room names have been revised to reflect separate gender restrooms. 3. Per IBC 1004.1.2 the occupant load factor for locker rooms is 50 gross. Therefore the occupant load for the space is 1414/50 = 29. Pierce + Frye Architects  Vail and San Francisco 970.949.0899  www.PierceFrye.com See 2-A0, Floor Plan – New – Occupant Load factor has been revised; area checked and revised; and occupant load has been updated accordingly. Lighting COMcheck Comments: 1. L1-L6 are powered by transformer, so in column D the fixture wattage should be wattage of the driver not the fixture itself ie: 48 watts of 96 watts per lighting specs. See Lighting Schedule on sheet A3. Per electrician, an alternate power supply was used to provide better dimming control and two, 200 watt power supplies will be used for fixtures L1 – L6. The COMcheck “Interior Lighting Compliance Certificate” has been revised to reflect the wattage of these two power supplies. Please contact us with any questions. Sincerely, Tom Frye Pierce + Frye Architects (415)392-4433 x2 tfrye@piercefrye.com Attachments via Drop Box folder: Gorsuch - Aspen - Locker Rm 191125 ARCH SET CO-1 PC2.pdf Gorsuch - Aspen - Locker Rm 191125 COMcheck LIGHTING COMP CO-1 PC2.pdf Linear LED Power Supply QTM-dc-cap-spec-sheet-s.pdf