HomeMy WebLinkAboutInspection.533 W Hallam St.0285.2018 (28).ARBKC RFS
1.
2
5
1.
2
5
1.25
1.25 1.25 1.25 1.25 1.251.251.251.25
1.251.251.25
1"
1"
411"
11.60
1"
1
0.012
1"
2
13.63
1"
3
2.234
1"
4
15.15
1"
5
0.277
1"
7
0.018
1"
8
0.279
1"
9
0.4610
1"
10
1.9211
1"
11
2.0812
1"
12
FS
1.
2
5
1.
2
5
1.
2
5
1"
1.25
0.936
1"
6
"11"
Turf Area Dripline Between Pavers
(see Legend and Valve Schedule)
1"
1"
1"
1"
"1
1"1"
IRRIGATION NOTES:
1.All work shall be per existing county or state code and is subject to
inspection and approval by appropriate inspectors and/or owner
representative. Installer to be responsible for all installation standards,
practices and all permit requirements.
2. Greg Mozian & Associates have provided all base and planting
information. Any discrepancies between said information and these
irrigation plans shall be their responsibility. The installer will assume all
costs and liabilities associated with any and all field changes to the
system design.
3.The system is designed to operate from the source with a flow of 20
gallons per minute (GPM) at 75 pounds per square inch (PSI) at the
point of connection. Unless otherwise noted on the plans, source flow
and pressure are the responsibility of others.
4.All pipe to be sleeved wherever concrete, asphalt, or any hard surfaces
are to be overlaid. All sleeves to be 2 times the diameter of the pipe to
be sleeved. Main line sleeves to have an additional 4" inch sleeve in
parallel for control wires.
5.Irrigation plan is a diagrammatic single line drawing. Any components
shown on plan outside of landscape are shown for clarity only. Multiple
pipes may be installed in the same trench when proper pipe spacing
can be maintained.
6.Main line to be buried 24" (inch) to top of pipe.
7.Control wires to be routed with main line and attached at 24"
increments with plastic wire ties or duct tape. Wire splices to be
located in a 10" (inch) round or larger valve box at least.
8.Swing pipe to be used on all sprinkler heads under 6 GPM and swing
joints on all heads over 6 GPM. Maximum length of swing pipe to be 5'
(foot).
9.Isolation valves to be located in 10" (inch) round valve box or larger.
10.For obstructions (Electrical Transformers, Trees, Fire Hydrants, etc...),
that will interfere with proper coverage of sprinkler heads, will require
the addition of properly patterned heads around obstruction as to
provide head to head coverage to all irrigated areas.
11.Sprinkler heads to be set perpendicular to finished grade and adjusted
to prevent over spray onto non irrigated areas.
12.Laterals are sized at transitions only, segments that are not noted will
be the same size as adjacent segments. Up stream segments will never
be smaller than any down stream segments on the same lateral.
13.Installer to submit two (2) soil samples from each of the amended areas
where installation of sub-surface drip is to be installed under turf grass.
Samples to be sent to Irrigation Designer for analysis and approval
prior to installation of sub-surface tubing and equipment to verify the
and application criteria are met. Failure of submittal could warrant
tubing replacement at installer's expense to pass audit requirements.
14.Project is designed to meet City of Aspen Water Efficient Landscaping
Standards adopted by Ordinance #17 series 2018. These standards
require a post installation inspection by the Certified Irrigation Designer
(CID) and an irrigation audit by a Certified Landscape Irrigation Auditor
(CLIA) as part of the approval letter process. Changes and variances to
the design must be approved by the Certified Irrigation Designer (CID)
prior to installation, unapproved changes may warrant failure of
inspection, corrections will be at installer's expense.
Ma
i
n
B
r
a
n
c
h
28
6
8
I
-
7
0
B
u
s
.
L
o
o
p
Gr
a
n
d
J
c
t
,
C
O
8
1
5
0
1
(9
7
0
)
2
4
3
-
4
6
0
4
Gr
a
n
d
J
u
n
c
t
i
o
n
Pi
p
e
&
S
u
p
p
l
y
Th
i
s
d
r
a
w
i
n
g
i
s
p
r
o
v
i
d
e
d
f
o
r
r
e
c
o
m
m
e
n
d
a
t
i
o
n
o
n
l
y
.
I
t
i
s
f
o
r
t
h
e
a
i
d
&
s
e
r
v
i
c
e
o
f
o
u
r
c
u
s
t
o
m
e
r
s
&
i
s
n
o
t
t
o
b
e
c
o
n
s
t
r
u
e
d
a
s
a
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
E
D
D
E
S
I
G
N
.
T
h
i
s
d
e
s
i
g
n
i
s
d
o
n
e
p
e
r
c
u
s
t
o
m
e
r
s
r
e
q
u
e
s
t
,
a
n
d
i
n
f
o
r
m
a
t
i
o
n
i
s
s
u
p
p
l
i
e
d
t
o
Gr
a
n
d
J
u
n
c
t
i
o
n
P
i
p
e
&
Su
p
p
l
y
b
y
t
h
e
c
u
s
t
o
m
e
r
.
A
n
y
c
h
a
n
g
e
s
,
a
d
d
i
t
i
o
n
s
,
o
r
o
m
i
s
s
i
o
n
s
w
i
l
l
e
f
f
e
c
t
t
h
e
d
e
s
i
g
n
a
n
d
p
e
r
f
o
r
m
a
n
c
e
o
f
t
h
i
s
s
y
s
t
e
m
.
D
u
e
t
o
n
o
n
-
i
n
s
p
e
c
t
i
o
n
o
f
s
i
t
e
l
o
c
a
t
i
o
n
a
n
d
c
o
n
s
t
r
u
c
t
i
o
n
p
r
o
c
e
d
u
r
e
s
.
GR
A
N
D
J
U
N
C
T
I
O
N
P
I
P
E
&
S
U
P
P
L
Y
I
S
N
O
T
R
E
S
P
O
N
S
I
B
L
E
F
O
R
D
A
M
A
G
E
T
H
A
T
CA
N
B
E
D
O
N
E
T
O
E
X
I
S
T
I
N
G
T
R
E
E
S
A
N
D
S
H
R
U
B
S
D
U
R
I
N
G
T
R
E
N
C
H
I
N
G
A
N
D
I
N
S
T
A
L
L
A
T
I
O
N
O
F
S
P
R
I
N
K
L
E
R
S
Y
S
T
E
M
.
CO
P
Y
R
I
G
H
T
N
O
T
I
C
E
:
T
h
i
s
d
r
a
w
i
n
g
i
s
a
n
i
n
s
t
r
u
m
e
n
t
o
f
s
e
r
v
i
c
e
a
n
d
i
s
t
h
e
p
r
o
p
e
r
t
y
o
f
Gr
a
n
d
J
u
n
c
t
i
o
n
P
i
p
e
&
S
u
p
p
l
y
.
N
o
r
e
p
r
o
d
u
c
t
i
o
n
o
f
t
h
i
s
s
h
e
e
t
i
n
w
h
o
l
e
o
r
p
a
r
t
,
f
o
r
t
h
i
s
o
r
a
n
y
o
t
h
e
r
p
r
o
j
e
c
t
,
s
h
a
l
l
b
e
d
o
n
e
w
i
t
h
o
u
t
a
u
t
h
o
r
i
z
a
t
i
o
n
f
r
o
m
Gr
a
n
d
J
u
n
c
t
i
o
n
P
i
p
e
&
S
u
p
p
l
y
.
53
3
W
E
S
T
H
A
L
L
A
M
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
Pr
o
j
e
c
t
T
i
t
l
e
:
Drawn By:
Designed By:
Checked By:
Drawing Number:
1 of 3
J.D.C.
.J.D.C.
2018-0126
1"=10'
11-27-2018
Drawing Scale:
Page:
Revisions:
..
Design Date:
Date DesignerNotes
.
PRELIMINARY
FINAL
FOR PERMIT
CONSTRUCTION
AS-BUILDS
Job Status:
IR-1
Sheet No.
File Name:
DU
N
C
A
N
R
E
S
I
D
E
N
C
E
SHEET TITLE:
2018-0126.DWG
Irrigation Plan
CALL 2 BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE
FOR THE MARKING OF UNDERGROUND
MEMBER UTILITIES
J.J.S.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY ARC
Rain Bird R-VAN24 1806-SAM-P45 21 Adj
Turf Rotary, 17`-24` 45°-270° and 360° Hand Adjustable
Multi-Stream Rotary w/1800 turf spray body on 6.0" pop-up, with check valve and
45 psi in-stem pressure regulator. 1/2" NPT Female Threaded Inlet.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Rain Bird XCZ-LF-100-PRF 1"10
Low Flow Drip Control Kit, 1" Low Flow Valve, 3/4" Pressure Regulating RBY
Filter, and 30psi Pressure Regulator. 0.2gpm-5gpm.
Pipe Transition Point 26
Pipe transition point from PVC lateral to drip tubing with riser
Turf Area to Receive Dripline
Rain Bird XFS-06-12 788.8 l.f.
XFS Sub-Surface Pressure Compensating Dripline w/Copper Shield Technology.
0.6 GPH emitters at 12" O.C. Laterals spaced at 12" apart, with emitters offset
for triangular pattern. UV Resistant. Specify XF insert fittings.
Area to Receive Dripline
Rain Bird XFS-06-18 529.2 l.f.
XFS Sub-Surface Pressure Compensating Dripline w/Copper Shield Technology.
0.6 GPH emitters at 18" O.C. Laterals spaced at 18" apart, with emitters offset
for triangular pattern. UV Resistant. Specify XF insert fittings.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY
Rain Bird DVF 1"2
Standard configuration, electric remote control valve. Plastic residential in 1".
With Flow Control.
Rain Bird 33-DRC 3/4"3
3/4" Brass Quick-Coupling Valve, with Corrosion-Resistant Stainless Steel
Spring, Thermoplastic Rubber Cover, Double Track Key Lug, and 2-Piece Body.
Locking Shut Off Valve 1
Master Valve Rain Bird PEB 1"1
1", 1-1/2", 2" Plastic Industrial Valves. Low Flow Operating Capability, Globe
Configuration.
Febco 825YA 1"1
Reduced Pressure Backflow Preventer
Hunter PHC-1200 1
Wi-Fi enabled, full-functioning controller with touchscreen, 12-Station fixed
controller, 120 VAC, Outdoor model.
Hunter WRF-CLIK (3)1
Rain/freeze Sensor, install within 1000 ft of controller, in line of sight. 22-28
VAC/VDC 100 mA power from timer transformer. Mount as noted. Includes
Gutter Mount.
Hunter FLOW-CLIK-100 (2)1
Flow Sensor SOV with Interface Panel, 1" Schedule 40 Sensor Body, 24 VAC, 2
amp, install Interface Panel as required.
Point of Connection 1"1
Irrigation Lateral Line: PVC Class 200 SDR 21 1"805.7 l.f.
Irrigation Mainline: PVC Schedule 40 1 1/4"230.6 l.f.
Pipe Sleeve: CPVC Schedule 40 15.8 l.f.
C
RFS
FS
1.25
#"
#
Valve Number
Valve Size
Valve Flow
Valve Callout
#
IRRIGATION SCHEDULE
NUMBER MODEL SIZE TYPE GPM WIRE PSI PRECIP HYDRO ZONE
1 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 1.60 56.3 46.98 0.43 in/h L = LOW DRIP
2 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.01 57.4 44.60 0.96 in/h VH = HIGH DRIP - PAVERS
3 Rain Bird DVFA 1"Turf Rotary 13.58 120.1 49.44 0.81 in/h VH = ROW - SPRAY
4 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 2.23 121.9 47.48 0.96 in/h VH = HIGH DRIP - TURF
5 Rain Bird DVFA 1"Turf Rotary 15.07 169.1 49.81 1.01 in/h VH = ROW - SPRAY
6 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.93 170.4 46.34 0.43 in/h L = LOW DRIP
7 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.27 181.4 44.76 0.43 in/h M = MEDIUM DRIP
8 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.01 207.9 44.60 0.96 in/h VH = HIGH DRIP - PAVERS
9 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.27 220.8 44.76 0.43 in/h M = MEDIUM DRIP
10 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.46 229.9 45.22 0.43 in/h L = LOW DRIP
11 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 1.92 232.1 47.24 0.96 in/h VH = HIGH DRIP - TURF
12 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 2.08 236.0 47.37 0.96 in/h VH = HIGH DRIP - TURF
Common Wire 230.5
VALVE SCHEDULE
I have complied with the
criteria of the Water Efficient
Landscaping Standards
and applied them accordingly
for the efficient use of water in
the irrigation design plan.
0 5 10 20
SCALE: 1" = 10'
NORTH
12/10/2018
Please include the language of WELS Section
4.3.2 (m) regarding irrigation work under
existing trees.
Please provide an emitter schedule
which indicates: plant type (trees,
shrubs, perennials, seeded areas)
and size by hydrozone, emitters per
plant, g.p.m. per emitter, and total
g.p.m. per plant.
C RFS
1.
2
5
1.
2
5
1.
2
5
1.
2
5
1.
2
5
1.251.25
1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.251.251.251.251.251.251.251.251.25
1.251.251.251.251.251.25 1.25
1"
1"
411"
11.60
1"
1
0.012
1"
2
13.63
1"
3
2.234
1"
4
15.15
1"
5
0.277
1"
7
0.018
1"
8
0.279
1"
9
0.4610
1"
10
1.9211
1"
11
2.0812
1"
12
FS
1.25
1.
2
5
1.
2
5
1.
2
5
1.
2
5
1.
2
5
1.
2
5
1.
2
5
1"
1.251.25
0.936
1"
6
"11"
Turf Area Dripline Between Pavers
(see Legend and Valve Schedule)
1"
1"
1"
1"
"1
1"1"
Ma
i
n
B
r
a
n
c
h
28
6
8
I
-
7
0
B
u
s
.
L
o
o
p
Gr
a
n
d
J
c
t
,
C
O
8
1
5
0
1
(9
7
0
)
2
4
3
-
4
6
0
4
Gr
a
n
d
J
u
n
c
t
i
o
n
Pi
p
e
&
S
u
p
p
l
y
Th
i
s
d
r
a
w
i
n
g
i
s
p
r
o
v
i
d
e
d
f
o
r
r
e
c
o
m
m
e
n
d
a
t
i
o
n
o
n
l
y
.
I
t
i
s
f
o
r
t
h
e
a
i
d
&
s
e
r
v
i
c
e
o
f
o
u
r
c
u
s
t
o
m
e
r
s
&
i
s
n
o
t
t
o
b
e
c
o
n
s
t
r
u
e
d
a
s
a
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
E
D
D
E
S
I
G
N
.
T
h
i
s
d
e
s
i
g
n
i
s
d
o
n
e
p
e
r
c
u
s
t
o
m
e
r
s
r
e
q
u
e
s
t
,
a
n
d
i
n
f
o
r
m
a
t
i
o
n
i
s
s
u
p
p
l
i
e
d
t
o
Gr
a
n
d
J
u
n
c
t
i
o
n
P
i
p
e
&
Su
p
p
l
y
b
y
t
h
e
c
u
s
t
o
m
e
r
.
A
n
y
c
h
a
n
g
e
s
,
a
d
d
i
t
i
o
n
s
,
o
r
o
m
i
s
s
i
o
n
s
w
i
l
l
e
f
f
e
c
t
t
h
e
d
e
s
i
g
n
a
n
d
p
e
r
f
o
r
m
a
n
c
e
o
f
t
h
i
s
s
y
s
t
e
m
.
D
u
e
t
o
n
o
n
-
i
n
s
p
e
c
t
i
o
n
o
f
s
i
t
e
l
o
c
a
t
i
o
n
a
n
d
c
o
n
s
t
r
u
c
t
i
o
n
p
r
o
c
e
d
u
r
e
s
.
GR
A
N
D
J
U
N
C
T
I
O
N
P
I
P
E
&
S
U
P
P
L
Y
I
S
N
O
T
R
E
S
P
O
N
S
I
B
L
E
F
O
R
D
A
M
A
G
E
T
H
A
T
CA
N
B
E
D
O
N
E
T
O
E
X
I
S
T
I
N
G
T
R
E
E
S
A
N
D
S
H
R
U
B
S
D
U
R
I
N
G
T
R
E
N
C
H
I
N
G
A
N
D
I
N
S
T
A
L
L
A
T
I
O
N
O
F
S
P
R
I
N
K
L
E
R
S
Y
S
T
E
M
.
CO
P
Y
R
I
G
H
T
N
O
T
I
C
E
:
T
h
i
s
d
r
a
w
i
n
g
i
s
a
n
i
n
s
t
r
u
m
e
n
t
o
f
s
e
r
v
i
c
e
a
n
d
i
s
t
h
e
p
r
o
p
e
r
t
y
o
f
Gr
a
n
d
J
u
n
c
t
i
o
n
P
i
p
e
&
S
u
p
p
l
y
.
N
o
r
e
p
r
o
d
u
c
t
i
o
n
o
f
t
h
i
s
s
h
e
e
t
i
n
w
h
o
l
e
o
r
p
a
r
t
,
f
o
r
t
h
i
s
o
r
a
n
y
o
t
h
e
r
p
r
o
j
e
c
t
,
s
h
a
l
l
b
e
d
o
n
e
w
i
t
h
o
u
t
a
u
t
h
o
r
i
z
a
t
i
o
n
f
r
o
m
Gr
a
n
d
J
u
n
c
t
i
o
n
P
i
p
e
&
S
u
p
p
l
y
.
53
3
W
E
S
T
H
A
L
L
A
M
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
Pr
o
j
e
c
t
T
i
t
l
e
:
Drawn By:
Designed By:
Checked By:
Drawing Number:
2 of 3
J.D.C.
.J.D.C.
2018-0126
1"=5'
11-27-2018
Drawing Scale:
Page:
Revisions:
..
Design Date:
Date DesignerNotes
.
PRELIMINARY
FINAL
FOR PERMIT
CONSTRUCTION
AS-BUILDS
Job Status:
IR-2
Sheet No.
File Name:
DU
N
C
A
N
R
E
S
I
D
E
N
C
E
SHEET TITLE:
2018-0126.DWG
Irrigation Plan
CALL 2 BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE
FOR THE MARKING OF UNDERGROUND
MEMBER UTILITIES
J.J.S.
I have complied with the
criteria of the Water Efficient
Landscaping Standards
and applied them accordingly
for the efficient use of water in
the irrigation design plan.
NORTH
12/10/2018
Ma
i
n
B
r
a
n
c
h
28
6
8
I
-
7
0
B
u
s
.
L
o
o
p
Gr
a
n
d
J
c
t
,
C
O
8
1
5
0
1
(9
7
0
)
2
4
3
-
4
6
0
4
Gr
a
n
d
J
u
n
c
t
i
o
n
Pi
p
e
&
S
u
p
p
l
y
Th
i
s
d
r
a
w
i
n
g
i
s
p
r
o
v
i
d
e
d
f
o
r
r
e
c
o
m
m
e
n
d
a
t
i
o
n
o
n
l
y
.
I
t
i
s
f
o
r
t
h
e
a
i
d
&
s
e
r
v
i
c
e
o
f
o
u
r
c
u
s
t
o
m
e
r
s
&
i
s
n
o
t
t
o
b
e
c
o
n
s
t
r
u
e
d
a
s
a
PR
O
F
E
S
S
I
O
N
A
L
E
N
G
I
N
E
E
R
E
D
D
E
S
I
G
N
.
T
h
i
s
d
e
s
i
g
n
i
s
d
o
n
e
p
e
r
c
u
s
t
o
m
e
r
s
r
e
q
u
e
s
t
,
a
n
d
i
n
f
o
r
m
a
t
i
o
n
i
s
s
u
p
p
l
i
e
d
t
o
Gr
a
n
d
J
u
n
c
t
i
o
n
P
i
p
e
&
Su
p
p
l
y
b
y
t
h
e
c
u
s
t
o
m
e
r
.
A
n
y
c
h
a
n
g
e
s
,
a
d
d
i
t
i
o
n
s
,
o
r
o
m
i
s
s
i
o
n
s
w
i
l
l
e
f
f
e
c
t
t
h
e
d
e
s
i
g
n
a
n
d
p
e
r
f
o
r
m
a
n
c
e
o
f
t
h
i
s
s
y
s
t
e
m
.
D
u
e
t
o
n
o
n
-
i
n
s
p
e
c
t
i
o
n
o
f
s
i
t
e
l
o
c
a
t
i
o
n
a
n
d
c
o
n
s
t
r
u
c
t
i
o
n
p
r
o
c
e
d
u
r
e
s
.
GR
A
N
D
J
U
N
C
T
I
O
N
P
I
P
E
&
S
U
P
P
L
Y
I
S
N
O
T
R
E
S
P
O
N
S
I
B
L
E
F
O
R
D
A
M
A
G
E
T
H
A
T
CA
N
B
E
D
O
N
E
T
O
E
X
I
S
T
I
N
G
T
R
E
E
S
A
N
D
S
H
R
U
B
S
D
U
R
I
N
G
T
R
E
N
C
H
I
N
G
A
N
D
I
N
S
T
A
L
L
A
T
I
O
N
O
F
S
P
R
I
N
K
L
E
R
S
Y
S
T
E
M
.
CO
P
Y
R
I
G
H
T
N
O
T
I
C
E
:
T
h
i
s
d
r
a
w
i
n
g
i
s
a
n
i
n
s
t
r
u
m
e
n
t
o
f
s
e
r
v
i
c
e
a
n
d
i
s
t
h
e
p
r
o
p
e
r
t
y
o
f
Gr
a
n
d
J
u
n
c
t
i
o
n
P
i
p
e
&
S
u
p
p
l
y
.
N
o
r
e
p
r
o
d
u
c
t
i
o
n
o
f
t
h
i
s
s
h
e
e
t
i
n
w
h
o
l
e
o
r
p
a
r
t
,
f
o
r
t
h
i
s
o
r
a
n
y
o
t
h
e
r
p
r
o
j
e
c
t
,
s
h
a
l
l
b
e
d
o
n
e
w
i
t
h
o
u
t
a
u
t
h
o
r
i
z
a
t
i
o
n
f
r
o
m
Gr
a
n
d
J
u
n
c
t
i
o
n
P
i
p
e
&
S
u
p
p
l
y
.
Pr
o
j
e
c
t
T
i
t
l
e
:
Drawn By:
Designed By:
Checked By:
Drawing Number:
3 of 3
see drawings
Drawing Scale:
Page:
Revisions:
..
Design Date:
Date DesignerNotes
.
PRELIMINARY
FINAL
FOR PERMIT
CONSTRUCTION
AS-BUILDS
Job Status:
IR-3
Sheet No.
File Name:
SHEET TITLE:
2018-0126.DWG
Irrigation Details
CALL 2 BUSINESS DAYS IN ADVANCE
BEFORE YOU DIG, GRADE OR EXCAVATE
FOR THE MARKING OF UNDERGROUND
MEMBER UTILITIES
4-1/4" WIDTH
(10.8 CM)1
3
2
4
NOTE
MOUNT CONTROLLER LCD SCREEN AT EYE
LEVEL, CONTROLLER SHALL BE HARD-WIRED
TO GROUNDED
110 VAC POWER SOURCE
LEGEND:
FRONT ELEVATION
RIGHT ELEVATION
10 1/2" (26.7 CM) OPEN DOOR WIDTH IRRIGATION CONTROLLER (PRO-HC) PER PLAN
IRRIGATION CONTROL WIRE IN CONDUIT
SIZE AND TYPE PER LOCAL CODES
ELECTRICAL SUPPLY CONDUIT
CONNECT TO POWER SOURCE, J-BOX INSIDE
CONTROLLER
ADJACENT SURFACE TO MOUNT CONTROLLER
PER PLAN
4
4
3
2
1
RAIN BIRD CONTROL VALVE (DVF-SERIES)-EL 90
1 1/2" = 1'-0"
PVC LATERAL
MAINLINE
(MS) X (VS) PVC COMBO TEE
(VS) X 6" SCH 80 PVC T.O.E. NIPPLE
(VS) SCH 80 PVC 90°
(VS) X 4" SCH 80 PVC T.O.E. NIPPLE
(VS) X 4" T.O.E. NIPPLE
(LS) SLIP COUPLING
(VS)=VALVE SIZE (LS)=LATERAL SIZE (MS)=MAINLINE SIZE
JUMBO or STANDARD VALVE BOX;
BUSHING (VS) X (LS); AS NEEDED
EXTRA 18" WIRE COIL
LID TO BE HOT STAMPED,
(BRANDED) WITH ZONE #
RAIN BIRD DVF-SERIES CONTROL VALVE
FINISH GRADE
BRICK TO SUPPORT & LEVEL
VALVE BOX
GEOTEXTILE SEPARATION FABRIC;
NO PLASTIC
12
"
M
I
N
.
18
"
M
A
X
.
3"
3/4" CRUSHED GRAVEL; 2" TO 3"
DEPTH
3" CLEAR SPACE FROM
BOTTOM OF VALVE TO
TOP OF GRAVEL
FABRIC TO EXTEND ABOVE
BOTTOM OF VALVE BOX
WATER PROOF WIRE
CONNECTOR
328406.13-05B
B MASTER VALVE & FLOW SENSOR
1 1/2" = 1'-0"
3"
18
M
X
.
DISTANCE PER PIPE SIZE
SPECIFIED FLOW METER WITH
150-2 MONITOR INSTALL WITH
20" MIN. INLET AND 10" MIN.
OUT LET; CONNECT TO
CONTROLLER
FINISHED GRADE
BRASS BALL VALVE
JUMBO VALVE BOX WITH
EXTENSION & BROWN LID
RAIN BIRD PEB MASTER
VALVE NORMALLY CLOSED
(VS) SCH 80 PVC UNION SLIP
TO SYSTEMFLOW
JUMBO VALVE BOX WITH
EXTENSION & BROWN LID
3" CLEAR SPACE FROM BOTTOM OF
VALVE TO TOP OF GRAVEL GEOTEXTILE SEPARATION FABRIC;
NO PLASTIC
3/4" CRUSHED GRAVEL; 2" TO
3" DEPTH
(VS0=VALVE SIZE (LS)=LATERAL SIZE (MS)=MAIN LINE SIZE (SS)=SUPPLY LINE SIZE
6"
CENTER BRICK TO
SUPPORT PIPE SECTION
DISTANCE PER PIPE SIZE
328406.23-62B
C
FEBCO 825YA RPA ASSEMBLY
1" = 1'-0"
FEBCO 825YA
(VS) X 4" BRASS NIPPLE (X2)
(VS) BRASS PLUG (X2)
(VS) X 12" BRASS NIPPLE
(VS) BRASS COUPLING
(VS) X 12" BRASS NIPPLE
(VS) BRASS 90° ELBOW
(VS) X 4" PVC T.O.E. NIPPLE
BUSHING (VS) X (LS) AS NEEDED
(MS) PVC SLIP COUPLING
FINISH GRADE
MI
N
.
1
2
"
MI
N
.
2
4
"
MAIN LINE TO VALVESFROM TAP (SS)
(SS) PVC SLIP COUPLING
BUSHING (SS) X (VS) AS NEEDED
(VS) X 4" PVC T.O.E. NIPPLE
(VS) BRASS 90° ELBOW
(VS) X12" BRASS NIPPLE
(VS)=VALVE SIZE (LS)=LATERAL SIZE (MS)=MAIN LINE SIZE (SS) SUPPLY LINE SIZE
328409.43-06B
D POP-UP SPRAY BODY W/ ROTARY NOZZLE
1 1/2" = 1'-0"
3
4
5
6 7 5 8
1
2
3
4
5
6
12
7
8
MULCH OR TURF GRASS
ROTARY NOZZLE
FINISHED GRADE
PVC/ POLY LATERAL
PIPE
POP-UP SPRAY BODY, RAIN
BIRD OR HUNTER
1/2 INCH MALE NPT BARB
ELBOW: RAIN BIRD MODEL
SBE-050
SWING PIPE, MIN.
2FT./MAX. 5FT. LENGTH;
SPX-100
PVC SCH 40 COMBO
TEE OR ELL
328403.36-01B
E
MF
DRIPLINE LAYOUT FOR IRREGULAR AREAS - SUBSUFACE/SURFACE AREAS
1 1/2" = 1'-0"
PERIMETER LATERALS 2" TO
4" FROM EDGE
SEE SPECIFICATIONS FOR ROW
SPACING
MANUAL FLUSH VALVE PLUMBED TO
SPECIFIED DRIPLINE
DRIPLINE TUBING
AS SPECIFIED ON
DRAWINGS
SPECIFIED DRIP CONNNECTION TEE
AREA PERIMETER
REMOTE CONTROL VALVE WITH DISC
FILTER AND PRESSURE REDUCER
VALVE
3
4" MIN. PVC/POLY TUBING TO
CONNECTION; SIZE BASED UPON
OVERALL SYSTEM DEMAND.
NOTE:
-CENTER FEED LITE LAYOUTS ALLOW 2X MAX.
TUBING LENGTH OF STANDARD LAYOUTS.
-CHECK VALVE HOLDS BACK 8.5' OF WATER; MAX.
LINE DISTANCE FOR CENTER FEED LITE LAYOUT @ 57
PSI INLET; REFER TO FULL CHART FOR ALTERNATE
PRESSURES:
.33 @ 12" O.C. = 1,056' .77 @ 12" O.C. = 606'
.33 @ 18" O.C. = 1,504' .77 @ 18" O.C. = 864'
.53 @ 12" O.C. = 774' 1.16 @ 12" O.C. = 460'
.53 @ 18" O.C. = 1,104' 1.16 @ 18" O.C. = 658'
328413.56-14B
H
HUNTER PRO-HC HYDROWISE IRRIGATION CONTROLLER
1 1/2" = 1'-0"DETAIL-FILE
IR-3
A
EPA WATERSENSE CERTIFIED SMART CONTROLLER
O
NO
F
F
ONO
F
F
LATERAL PIPE TO RISERS
1" LOW-FLOW-DV VALVE
1" PR-RBY-FILTER
1-1/4" x 1"COMBO TEE
ON MAIN LINE STANDARD VALVE BOX
1" SLIP X FIPT
1" X 3" NIPPLE
1-1/4" COUPLING
1" X 1-1/4" Slip X Female Bushing
1-1/4" CLASS 160 PVC PIPE 3/4" POLY DRIP PIPE
1" PVC FEMALE ADAPTER
1" ELECTRIC VALVE DV-100
1" WYE STRAINER
w/40 PSI PRESSURE REGULATOR
1" COMBO TEE
ON MAIN LINE
STANDARD VALVE BOX
1" x 3" SCH-80
PVC THREADED NIPPLE
1" x 3/4" PVC
SLIP x FIPT BUSHING
3/4" IPOLY INSERT MALE ADAPTER
W/CLAMP
XCZ 100 PRF CONTROL ZONE
1 1/2" = 1'-0"
F
IR-3 DETAIL-FILE
33 DRC QUICK COUPLER ON SWING JOINT
1 1/2" = 1'-0"
G
IR-3
2" SS HOSE CLAMP
12"-36" REBAR
(SUPPLIED BY OTHERS)
RAIN BIRD 33 DRC QUICK COUPLER
RAIN BIRD UNITIZED SWING JOINT.
ADJUST ANGLE OF SWING JOINT LAY ARM
BETWEEN 30° TO 45° TO ALLOW ADEQUATE
IMPACT ABSORPTION.
MAIN LINE PVC TEE
R
53
3
W
E
S
T
H
A
L
L
A
M
S
T
R
E
E
T
AS
P
E
N
,
C
O
L
O
R
A
D
O
8
1
6
1
1
J.D.C.
J.D.C.
2018-0126
11-27-2018
DU
N
C
A
N
R
E
S
I
D
E
N
C
E
J.J.S.
12/10/2018