Loading...
HomeMy WebLinkAboutInspection.533 W Hallam St.0285.2018 (28).ARBKC RFS 1. 2 5 1. 2 5 1.25 1.25 1.25 1.25 1.25 1.251.251.251.25 1.251.251.25 1" 1" 411" 11.60 1" 1 0.012 1" 2 13.63 1" 3 2.234 1" 4 15.15 1" 5 0.277 1" 7 0.018 1" 8 0.279 1" 9 0.4610 1" 10 1.9211 1" 11 2.0812 1" 12 FS 1. 2 5 1. 2 5 1. 2 5 1" 1.25 0.936 1" 6 "11" Turf Area Dripline Between Pavers (see Legend and Valve Schedule) 1" 1" 1" 1" "1 1"1" IRRIGATION NOTES: 1.All work shall be per existing county or state code and is subject to inspection and approval by appropriate inspectors and/or owner representative. Installer to be responsible for all installation standards, practices and all permit requirements. 2. Greg Mozian & Associates have provided all base and planting information. Any discrepancies between said information and these irrigation plans shall be their responsibility. The installer will assume all costs and liabilities associated with any and all field changes to the system design. 3.The system is designed to operate from the source with a flow of 20 gallons per minute (GPM) at 75 pounds per square inch (PSI) at the point of connection. Unless otherwise noted on the plans, source flow and pressure are the responsibility of others. 4.All pipe to be sleeved wherever concrete, asphalt, or any hard surfaces are to be overlaid. All sleeves to be 2 times the diameter of the pipe to be sleeved. Main line sleeves to have an additional 4" inch sleeve in parallel for control wires. 5.Irrigation plan is a diagrammatic single line drawing. Any components shown on plan outside of landscape are shown for clarity only. Multiple pipes may be installed in the same trench when proper pipe spacing can be maintained. 6.Main line to be buried 24" (inch) to top of pipe. 7.Control wires to be routed with main line and attached at 24" increments with plastic wire ties or duct tape. Wire splices to be located in a 10" (inch) round or larger valve box at least. 8.Swing pipe to be used on all sprinkler heads under 6 GPM and swing joints on all heads over 6 GPM. Maximum length of swing pipe to be 5' (foot). 9.Isolation valves to be located in 10" (inch) round valve box or larger. 10.For obstructions (Electrical Transformers, Trees, Fire Hydrants, etc...), that will interfere with proper coverage of sprinkler heads, will require the addition of properly patterned heads around obstruction as to provide head to head coverage to all irrigated areas. 11.Sprinkler heads to be set perpendicular to finished grade and adjusted to prevent over spray onto non irrigated areas. 12.Laterals are sized at transitions only, segments that are not noted will be the same size as adjacent segments. Up stream segments will never be smaller than any down stream segments on the same lateral. 13.Installer to submit two (2) soil samples from each of the amended areas where installation of sub-surface drip is to be installed under turf grass. Samples to be sent to Irrigation Designer for analysis and approval prior to installation of sub-surface tubing and equipment to verify the and application criteria are met. Failure of submittal could warrant tubing replacement at installer's expense to pass audit requirements. 14.Project is designed to meet City of Aspen Water Efficient Landscaping Standards adopted by Ordinance #17 series 2018. These standards require a post installation inspection by the Certified Irrigation Designer (CID) and an irrigation audit by a Certified Landscape Irrigation Auditor (CLIA) as part of the approval letter process. Changes and variances to the design must be approved by the Certified Irrigation Designer (CID) prior to installation, unapproved changes may warrant failure of inspection, corrections will be at installer's expense. Ma i n B r a n c h 28 6 8 I - 7 0 B u s . L o o p Gr a n d J c t , C O 8 1 5 0 1 (9 7 0 ) 2 4 3 - 4 6 0 4 Gr a n d J u n c t i o n Pi p e & S u p p l y Th i s d r a w i n g i s p r o v i d e d f o r r e c o m m e n d a t i o n o n l y . I t i s f o r t h e a i d & s e r v i c e o f o u r c u s t o m e r s & i s n o t t o b e c o n s t r u e d a s a PR O F E S S I O N A L E N G I N E E R E D D E S I G N . T h i s d e s i g n i s d o n e p e r c u s t o m e r s r e q u e s t , a n d i n f o r m a t i o n i s s u p p l i e d t o Gr a n d J u n c t i o n P i p e & Su p p l y b y t h e c u s t o m e r . A n y c h a n g e s , a d d i t i o n s , o r o m i s s i o n s w i l l e f f e c t t h e d e s i g n a n d p e r f o r m a n c e o f t h i s s y s t e m . D u e t o n o n - i n s p e c t i o n o f s i t e l o c a t i o n a n d c o n s t r u c t i o n p r o c e d u r e s . GR A N D J U N C T I O N P I P E & S U P P L Y I S N O T R E S P O N S I B L E F O R D A M A G E T H A T CA N B E D O N E T O E X I S T I N G T R E E S A N D S H R U B S D U R I N G T R E N C H I N G A N D I N S T A L L A T I O N O F S P R I N K L E R S Y S T E M . CO P Y R I G H T N O T I C E : T h i s d r a w i n g i s a n i n s t r u m e n t o f s e r v i c e a n d i s t h e p r o p e r t y o f Gr a n d J u n c t i o n P i p e & S u p p l y . N o r e p r o d u c t i o n o f t h i s s h e e t i n w h o l e o r p a r t , f o r t h i s o r a n y o t h e r p r o j e c t , s h a l l b e d o n e w i t h o u t a u t h o r i z a t i o n f r o m Gr a n d J u n c t i o n P i p e & S u p p l y . 53 3 W E S T H A L L A M S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 Pr o j e c t T i t l e : Drawn By: Designed By: Checked By: Drawing Number: 1 of 3 J.D.C. .J.D.C. 2018-0126 1"=10' 11-27-2018 Drawing Scale: Page: Revisions: .. Design Date: Date DesignerNotes . PRELIMINARY FINAL FOR PERMIT CONSTRUCTION AS-BUILDS Job Status: IR-1 Sheet No. File Name: DU N C A N R E S I D E N C E SHEET TITLE: 2018-0126.DWG Irrigation Plan CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES J.J.S. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY ARC Rain Bird R-VAN24 1806-SAM-P45 21 Adj Turf Rotary, 17`-24` 45°-270° and 360° Hand Adjustable Multi-Stream Rotary w/1800 turf spray body on 6.0" pop-up, with check valve and 45 psi in-stem pressure regulator. 1/2" NPT Female Threaded Inlet. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY Rain Bird XCZ-LF-100-PRF 1"10 Low Flow Drip Control Kit, 1" Low Flow Valve, 3/4" Pressure Regulating RBY Filter, and 30psi Pressure Regulator. 0.2gpm-5gpm. Pipe Transition Point 26 Pipe transition point from PVC lateral to drip tubing with riser Turf Area to Receive Dripline Rain Bird XFS-06-12 788.8 l.f. XFS Sub-Surface Pressure Compensating Dripline w/Copper Shield Technology. 0.6 GPH emitters at 12" O.C. Laterals spaced at 12" apart, with emitters offset for triangular pattern. UV Resistant. Specify XF insert fittings. Area to Receive Dripline Rain Bird XFS-06-18 529.2 l.f. XFS Sub-Surface Pressure Compensating Dripline w/Copper Shield Technology. 0.6 GPH emitters at 18" O.C. Laterals spaced at 18" apart, with emitters offset for triangular pattern. UV Resistant. Specify XF insert fittings. SYMBOL MANUFACTURER/MODEL/DESCRIPTION QTY Rain Bird DVF 1"2 Standard configuration, electric remote control valve. Plastic residential in 1". With Flow Control. Rain Bird 33-DRC 3/4"3 3/4" Brass Quick-Coupling Valve, with Corrosion-Resistant Stainless Steel Spring, Thermoplastic Rubber Cover, Double Track Key Lug, and 2-Piece Body. Locking Shut Off Valve 1 Master Valve Rain Bird PEB 1"1 1", 1-1/2", 2" Plastic Industrial Valves. Low Flow Operating Capability, Globe Configuration. Febco 825YA 1"1 Reduced Pressure Backflow Preventer Hunter PHC-1200 1 Wi-Fi enabled, full-functioning controller with touchscreen, 12-Station fixed controller, 120 VAC, Outdoor model. Hunter WRF-CLIK (3)1 Rain/freeze Sensor, install within 1000 ft of controller, in line of sight. 22-28 VAC/VDC 100 mA power from timer transformer. Mount as noted. Includes Gutter Mount. Hunter FLOW-CLIK-100 (2)1 Flow Sensor SOV with Interface Panel, 1" Schedule 40 Sensor Body, 24 VAC, 2 amp, install Interface Panel as required. Point of Connection 1"1 Irrigation Lateral Line: PVC Class 200 SDR 21 1"805.7 l.f. Irrigation Mainline: PVC Schedule 40 1 1/4"230.6 l.f. Pipe Sleeve: CPVC Schedule 40 15.8 l.f. C RFS FS 1.25 #" # Valve Number Valve Size Valve Flow Valve Callout # IRRIGATION SCHEDULE NUMBER MODEL SIZE TYPE GPM WIRE PSI PRECIP HYDRO ZONE 1 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 1.60 56.3 46.98 0.43 in/h L = LOW DRIP 2 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.01 57.4 44.60 0.96 in/h VH = HIGH DRIP - PAVERS 3 Rain Bird DVFA 1"Turf Rotary 13.58 120.1 49.44 0.81 in/h VH = ROW - SPRAY 4 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 2.23 121.9 47.48 0.96 in/h VH = HIGH DRIP - TURF 5 Rain Bird DVFA 1"Turf Rotary 15.07 169.1 49.81 1.01 in/h VH = ROW - SPRAY 6 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.93 170.4 46.34 0.43 in/h L = LOW DRIP 7 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.27 181.4 44.76 0.43 in/h M = MEDIUM DRIP 8 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.01 207.9 44.60 0.96 in/h VH = HIGH DRIP - PAVERS 9 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.27 220.8 44.76 0.43 in/h M = MEDIUM DRIP 10 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 0.46 229.9 45.22 0.43 in/h L = LOW DRIP 11 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 1.92 232.1 47.24 0.96 in/h VH = HIGH DRIP - TURF 12 Rain Bird XCZ-LF-100-PRF 1"Area for Dripline 2.08 236.0 47.37 0.96 in/h VH = HIGH DRIP - TURF Common Wire 230.5 VALVE SCHEDULE I have complied with the criteria of the Water Efficient Landscaping Standards and applied them accordingly for the efficient use of water in the irrigation design plan. 0 5 10 20 SCALE: 1" = 10' NORTH 12/10/2018 Please include the language of WELS Section 4.3.2 (m) regarding irrigation work under existing trees. Please provide an emitter schedule which indicates: plant type (trees, shrubs, perennials, seeded areas) and size by hydrozone, emitters per plant, g.p.m. per emitter, and total g.p.m. per plant. C RFS 1. 2 5 1. 2 5 1. 2 5 1. 2 5 1. 2 5 1.251.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.251.251.251.251.251.251.251.251.25 1.251.251.251.251.251.25 1.25 1" 1" 411" 11.60 1" 1 0.012 1" 2 13.63 1" 3 2.234 1" 4 15.15 1" 5 0.277 1" 7 0.018 1" 8 0.279 1" 9 0.4610 1" 10 1.9211 1" 11 2.0812 1" 12 FS 1.25 1. 2 5 1. 2 5 1. 2 5 1. 2 5 1. 2 5 1. 2 5 1. 2 5 1" 1.251.25 0.936 1" 6 "11" Turf Area Dripline Between Pavers (see Legend and Valve Schedule) 1" 1" 1" 1" "1 1"1" Ma i n B r a n c h 28 6 8 I - 7 0 B u s . L o o p Gr a n d J c t , C O 8 1 5 0 1 (9 7 0 ) 2 4 3 - 4 6 0 4 Gr a n d J u n c t i o n Pi p e & S u p p l y Th i s d r a w i n g i s p r o v i d e d f o r r e c o m m e n d a t i o n o n l y . I t i s f o r t h e a i d & s e r v i c e o f o u r c u s t o m e r s & i s n o t t o b e c o n s t r u e d a s a PR O F E S S I O N A L E N G I N E E R E D D E S I G N . T h i s d e s i g n i s d o n e p e r c u s t o m e r s r e q u e s t , a n d i n f o r m a t i o n i s s u p p l i e d t o Gr a n d J u n c t i o n P i p e & Su p p l y b y t h e c u s t o m e r . A n y c h a n g e s , a d d i t i o n s , o r o m i s s i o n s w i l l e f f e c t t h e d e s i g n a n d p e r f o r m a n c e o f t h i s s y s t e m . D u e t o n o n - i n s p e c t i o n o f s i t e l o c a t i o n a n d c o n s t r u c t i o n p r o c e d u r e s . GR A N D J U N C T I O N P I P E & S U P P L Y I S N O T R E S P O N S I B L E F O R D A M A G E T H A T CA N B E D O N E T O E X I S T I N G T R E E S A N D S H R U B S D U R I N G T R E N C H I N G A N D I N S T A L L A T I O N O F S P R I N K L E R S Y S T E M . CO P Y R I G H T N O T I C E : T h i s d r a w i n g i s a n i n s t r u m e n t o f s e r v i c e a n d i s t h e p r o p e r t y o f Gr a n d J u n c t i o n P i p e & S u p p l y . N o r e p r o d u c t i o n o f t h i s s h e e t i n w h o l e o r p a r t , f o r t h i s o r a n y o t h e r p r o j e c t , s h a l l b e d o n e w i t h o u t a u t h o r i z a t i o n f r o m Gr a n d J u n c t i o n P i p e & S u p p l y . 53 3 W E S T H A L L A M S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 Pr o j e c t T i t l e : Drawn By: Designed By: Checked By: Drawing Number: 2 of 3 J.D.C. .J.D.C. 2018-0126 1"=5' 11-27-2018 Drawing Scale: Page: Revisions: .. Design Date: Date DesignerNotes . PRELIMINARY FINAL FOR PERMIT CONSTRUCTION AS-BUILDS Job Status: IR-2 Sheet No. File Name: DU N C A N R E S I D E N C E SHEET TITLE: 2018-0126.DWG Irrigation Plan CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES J.J.S. I have complied with the criteria of the Water Efficient Landscaping Standards and applied them accordingly for the efficient use of water in the irrigation design plan. NORTH 12/10/2018 Ma i n B r a n c h 28 6 8 I - 7 0 B u s . L o o p Gr a n d J c t , C O 8 1 5 0 1 (9 7 0 ) 2 4 3 - 4 6 0 4 Gr a n d J u n c t i o n Pi p e & S u p p l y Th i s d r a w i n g i s p r o v i d e d f o r r e c o m m e n d a t i o n o n l y . I t i s f o r t h e a i d & s e r v i c e o f o u r c u s t o m e r s & i s n o t t o b e c o n s t r u e d a s a PR O F E S S I O N A L E N G I N E E R E D D E S I G N . T h i s d e s i g n i s d o n e p e r c u s t o m e r s r e q u e s t , a n d i n f o r m a t i o n i s s u p p l i e d t o Gr a n d J u n c t i o n P i p e & Su p p l y b y t h e c u s t o m e r . A n y c h a n g e s , a d d i t i o n s , o r o m i s s i o n s w i l l e f f e c t t h e d e s i g n a n d p e r f o r m a n c e o f t h i s s y s t e m . D u e t o n o n - i n s p e c t i o n o f s i t e l o c a t i o n a n d c o n s t r u c t i o n p r o c e d u r e s . GR A N D J U N C T I O N P I P E & S U P P L Y I S N O T R E S P O N S I B L E F O R D A M A G E T H A T CA N B E D O N E T O E X I S T I N G T R E E S A N D S H R U B S D U R I N G T R E N C H I N G A N D I N S T A L L A T I O N O F S P R I N K L E R S Y S T E M . CO P Y R I G H T N O T I C E : T h i s d r a w i n g i s a n i n s t r u m e n t o f s e r v i c e a n d i s t h e p r o p e r t y o f Gr a n d J u n c t i o n P i p e & S u p p l y . N o r e p r o d u c t i o n o f t h i s s h e e t i n w h o l e o r p a r t , f o r t h i s o r a n y o t h e r p r o j e c t , s h a l l b e d o n e w i t h o u t a u t h o r i z a t i o n f r o m Gr a n d J u n c t i o n P i p e & S u p p l y . Pr o j e c t T i t l e : Drawn By: Designed By: Checked By: Drawing Number: 3 of 3 see drawings Drawing Scale: Page: Revisions: .. Design Date: Date DesignerNotes . PRELIMINARY FINAL FOR PERMIT CONSTRUCTION AS-BUILDS Job Status: IR-3 Sheet No. File Name: SHEET TITLE: 2018-0126.DWG Irrigation Details CALL 2 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES 4-1/4" WIDTH (10.8 CM)1 3 2 4 NOTE MOUNT CONTROLLER LCD SCREEN AT EYE LEVEL, CONTROLLER SHALL BE HARD-WIRED TO GROUNDED 110 VAC POWER SOURCE LEGEND: FRONT ELEVATION RIGHT ELEVATION 10 1/2" (26.7 CM) OPEN DOOR WIDTH IRRIGATION CONTROLLER (PRO-HC) PER PLAN IRRIGATION CONTROL WIRE IN CONDUIT SIZE AND TYPE PER LOCAL CODES ELECTRICAL SUPPLY CONDUIT CONNECT TO POWER SOURCE, J-BOX INSIDE CONTROLLER ADJACENT SURFACE TO MOUNT CONTROLLER PER PLAN 4 4 3 2 1 RAIN BIRD CONTROL VALVE (DVF-SERIES)-EL 90 1 1/2" = 1'-0" PVC LATERAL MAINLINE (MS) X (VS) PVC COMBO TEE (VS) X 6" SCH 80 PVC T.O.E. NIPPLE (VS) SCH 80 PVC 90° (VS) X 4" SCH 80 PVC T.O.E. NIPPLE (VS) X 4" T.O.E. NIPPLE (LS) SLIP COUPLING (VS)=VALVE SIZE (LS)=LATERAL SIZE (MS)=MAINLINE SIZE JUMBO or STANDARD VALVE BOX; BUSHING (VS) X (LS); AS NEEDED EXTRA 18" WIRE COIL LID TO BE HOT STAMPED, (BRANDED) WITH ZONE # RAIN BIRD DVF-SERIES CONTROL VALVE FINISH GRADE BRICK TO SUPPORT & LEVEL VALVE BOX GEOTEXTILE SEPARATION FABRIC; NO PLASTIC 12 " M I N . 18 " M A X . 3" 3/4" CRUSHED GRAVEL; 2" TO 3" DEPTH 3" CLEAR SPACE FROM BOTTOM OF VALVE TO TOP OF GRAVEL FABRIC TO EXTEND ABOVE BOTTOM OF VALVE BOX WATER PROOF WIRE CONNECTOR 328406.13-05B B MASTER VALVE & FLOW SENSOR 1 1/2" = 1'-0" 3" 18 M X . DISTANCE PER PIPE SIZE SPECIFIED FLOW METER WITH 150-2 MONITOR INSTALL WITH 20" MIN. INLET AND 10" MIN. OUT LET; CONNECT TO CONTROLLER FINISHED GRADE BRASS BALL VALVE JUMBO VALVE BOX WITH EXTENSION & BROWN LID RAIN BIRD PEB MASTER VALVE NORMALLY CLOSED (VS) SCH 80 PVC UNION SLIP TO SYSTEMFLOW JUMBO VALVE BOX WITH EXTENSION & BROWN LID 3" CLEAR SPACE FROM BOTTOM OF VALVE TO TOP OF GRAVEL GEOTEXTILE SEPARATION FABRIC; NO PLASTIC 3/4" CRUSHED GRAVEL; 2" TO 3" DEPTH (VS0=VALVE SIZE (LS)=LATERAL SIZE (MS)=MAIN LINE SIZE (SS)=SUPPLY LINE SIZE 6" CENTER BRICK TO SUPPORT PIPE SECTION DISTANCE PER PIPE SIZE 328406.23-62B C FEBCO 825YA RPA ASSEMBLY 1" = 1'-0" FEBCO 825YA (VS) X 4" BRASS NIPPLE (X2) (VS) BRASS PLUG (X2) (VS) X 12" BRASS NIPPLE (VS) BRASS COUPLING (VS) X 12" BRASS NIPPLE (VS) BRASS 90° ELBOW (VS) X 4" PVC T.O.E. NIPPLE BUSHING (VS) X (LS) AS NEEDED (MS) PVC SLIP COUPLING FINISH GRADE MI N . 1 2 " MI N . 2 4 " MAIN LINE TO VALVESFROM TAP (SS) (SS) PVC SLIP COUPLING BUSHING (SS) X (VS) AS NEEDED (VS) X 4" PVC T.O.E. NIPPLE (VS) BRASS 90° ELBOW (VS) X12" BRASS NIPPLE (VS)=VALVE SIZE (LS)=LATERAL SIZE (MS)=MAIN LINE SIZE (SS) SUPPLY LINE SIZE 328409.43-06B D POP-UP SPRAY BODY W/ ROTARY NOZZLE 1 1/2" = 1'-0" 3 4 5 6 7 5 8 1 2 3 4 5 6 12 7 8 MULCH OR TURF GRASS ROTARY NOZZLE FINISHED GRADE PVC/ POLY LATERAL PIPE POP-UP SPRAY BODY, RAIN BIRD OR HUNTER 1/2 INCH MALE NPT BARB ELBOW: RAIN BIRD MODEL SBE-050 SWING PIPE, MIN. 2FT./MAX. 5FT. LENGTH; SPX-100 PVC SCH 40 COMBO TEE OR ELL 328403.36-01B E MF DRIPLINE LAYOUT FOR IRREGULAR AREAS - SUBSUFACE/SURFACE AREAS 1 1/2" = 1'-0" PERIMETER LATERALS 2" TO 4" FROM EDGE SEE SPECIFICATIONS FOR ROW SPACING MANUAL FLUSH VALVE PLUMBED TO SPECIFIED DRIPLINE DRIPLINE TUBING AS SPECIFIED ON DRAWINGS SPECIFIED DRIP CONNNECTION TEE AREA PERIMETER REMOTE CONTROL VALVE WITH DISC FILTER AND PRESSURE REDUCER VALVE 3 4" MIN. PVC/POLY TUBING TO CONNECTION; SIZE BASED UPON OVERALL SYSTEM DEMAND. NOTE: -CENTER FEED LITE LAYOUTS ALLOW 2X MAX. TUBING LENGTH OF STANDARD LAYOUTS. -CHECK VALVE HOLDS BACK 8.5' OF WATER; MAX. LINE DISTANCE FOR CENTER FEED LITE LAYOUT @ 57 PSI INLET; REFER TO FULL CHART FOR ALTERNATE PRESSURES: .33 @ 12" O.C. = 1,056' .77 @ 12" O.C. = 606' .33 @ 18" O.C. = 1,504' .77 @ 18" O.C. = 864' .53 @ 12" O.C. = 774' 1.16 @ 12" O.C. = 460' .53 @ 18" O.C. = 1,104' 1.16 @ 18" O.C. = 658' 328413.56-14B H HUNTER PRO-HC HYDROWISE IRRIGATION CONTROLLER 1 1/2" = 1'-0"DETAIL-FILE IR-3 A EPA WATERSENSE CERTIFIED SMART CONTROLLER O NO F F ONO F F LATERAL PIPE TO RISERS 1" LOW-FLOW-DV VALVE 1" PR-RBY-FILTER 1-1/4" x 1"COMBO TEE ON MAIN LINE STANDARD VALVE BOX 1" SLIP X FIPT 1" X 3" NIPPLE 1-1/4" COUPLING 1" X 1-1/4" Slip X Female Bushing 1-1/4" CLASS 160 PVC PIPE 3/4" POLY DRIP PIPE 1" PVC FEMALE ADAPTER 1" ELECTRIC VALVE DV-100 1" WYE STRAINER w/40 PSI PRESSURE REGULATOR 1" COMBO TEE ON MAIN LINE STANDARD VALVE BOX 1" x 3" SCH-80 PVC THREADED NIPPLE 1" x 3/4" PVC SLIP x FIPT BUSHING 3/4" IPOLY INSERT MALE ADAPTER W/CLAMP XCZ 100 PRF CONTROL ZONE 1 1/2" = 1'-0" F IR-3 DETAIL-FILE 33 DRC QUICK COUPLER ON SWING JOINT 1 1/2" = 1'-0" G IR-3 2" SS HOSE CLAMP 12"-36" REBAR (SUPPLIED BY OTHERS) RAIN BIRD 33 DRC QUICK COUPLER RAIN BIRD UNITIZED SWING JOINT. ADJUST ANGLE OF SWING JOINT LAY ARM BETWEEN 30° TO 45° TO ALLOW ADEQUATE IMPACT ABSORPTION. MAIN LINE PVC TEE R 53 3 W E S T H A L L A M S T R E E T AS P E N , C O L O R A D O 8 1 6 1 1 J.D.C. J.D.C. 2018-0126 11-27-2018 DU N C A N R E S I D E N C E J.J.S. 12/10/2018