HomeMy WebLinkAboutFile Documents.430 W Hallam St.0291.2017 (101).ARBKRadon Solutions, LLCRadon Solutions, LLC
Glenwood Springs, COLORADO 81601
970-987-9752
Radon Inspection Repor tRadon Inspection Repor t
Test Location:Test Location:
C/O Koru
430 W Hallam
Aspen, CO 81611
Test For:Test For: Inspected By:Inspected By:
Glenwood Springs, COLORADO 81601
970-987-9752
Test Result: PassTest Result: Pass
Overall Average:Overall Average:
1.2 pCi/l1.2 pCi/l
EPA Average:EPA Average:
1.3 pCi/l1.3 pCi/l
Test Device Details:Test Device Details:
Serial Number:
Model Number:
Last Calibration:
Next Calibration:
Cal-Factors:
Motion Error:
valuesvalues
247925003
1030
01/18/2024
01/18/2025
2.36,2.44,2.51,2.42,2.37,2.38
Yes
Test Site Condition:Test Site Condition:
Mitigation Sys:
valuesvalues
Installed but not Active
Test Summary:Test Summary:
CRM Location:
Downstairs media room
Start:Start:
Start:
04/06/2024
03:01 AM
Stop:Stop:
Stop:
04/08/2024
03:01 AM
Interval:Interval:
Interval:
1 hr
Duration:Duration:
Duration:
48 hr
**First 4 hrs of data excluded
Radon Concentration:
Min:
0.5
Max:
2.6
Average:
1.3
Measurement Units:
pCi/l
Temperature 74.8 75.9 75.2 F
Humidity 30 31 31 %
Pressure 22.36 22.66 22.54 inHg
Comments:Comments:
Passive radon system installed
Lic/Cert SignatureLic/Cert Signature Inspection Report Date:Inspection Report Date: 04/08/2024
Test device manufactured by SunRADON, LLC OneRADON™ Version 2.4.28
Page 1 of 6
Radon Solutions, LLCRadon Solutions, LLC
Glenwood Springs, COLORADO 81601
970-987-9752
Radon Inspection ChartRadon Inspection Chart
Test Result: PassTest Result: Pass
Test Location:Test Location: 430 W Hallam Aspen, CO 81611 Inspection Report Date:Inspection Report Date: 04/08/2024
Test device manufactured by SunRADON, LLC
Page 2 of 6
Radon Solutions, LLCRadon Solutions, LLC
Glenwood Springs, COLORADO 81601
970-987-9752
Test ChecklistTest Checklist
The location of the detector was selected so the detector was not to be disturbed during testing.
The monitor was not placed in an area of high humidity such as: Kitchen, laundry room, cellar, spa room, garage, crawl
space or sump area.
The detector was not located near drafts caused by HVAC vents, windows and doors.
Whole house fans were turned off during the testing.
The detector was not placed near areas of excessive heat, such as a fireplace or in direct sunlight.
Portable window fans were removed or sealed in place prior to testing.
The detector was placed within the breathing zone of at least 20 inches to 6 feet above the floor and at least 1 foot
below the ceiling if suspended.
Window air conditioners were operable in recirculation mode only.
The detector was not placed within 1 foot of outside walls of the home or within 3 feet of any windows or doors to the
exterior of the home.
Ceiling fans, portable dehumidifiers, portable humidifiers, portable air filters, and all window air conditioners are not
operated within 20 feet of the detector.
Test Result: PassTest Result: Pass
Test Location:Test Location: 430 W Hallam Aspen, CO 81611 Inspection Report Date:Inspection Report Date: 04/08/2024
Test device manufactured by SunRADON, LLC
Page 3 of 6
Radon Solutions, LLCRadon Solutions, LLC
Glenwood Springs, COLORADO 81601
970-987-9752
Test TableTest Table
* Data from first 4 hours excluded from EPA calculations
Date/Time Radon(pCi/l)Temp(F)Pres(inHg)Humidity(%)Flags
04/06/24 04:01 AM 1.1 75.7 22.36 31 -
04/06/24 05:01 AM 0.6 75.7 22.36 31 -
04/06/24 06:01 AM 0.7 75.6 22.35 31 -
04/06/24 07:01 AM 1.1 75.6 22.36 31 -
04/06/24 08:01 AM 1.1 75.4 22.37 31 M
04/06/24 09:01 AM 0.8 75.2 22.36 30 -
04/06/24 10:01 AM 0.8 75.2 22.36 31 -
04/06/24 11:01 AM 1.4 75.4 22.40 30 -
04/06/24 12:01 PM 0.8 75.4 22.40 30 M
04/06/24 01:01 PM 0.5 75.4 22.41 30 -
04/06/24 02:01 PM 0.5 75.4 22.44 30 -
04/06/24 03:01 PM 0.7 75.6 22.44 30 M
04/06/24 04:01 PM 0.7 75.6 22.44 30 -
04/06/24 05:01 PM 1.3 75.9 22.43 31 -
04/06/24 06:01 PM 0.6 75.7 22.46 31 -
04/06/24 07:01 PM 0.5 75.6 22.48 31 -
04/06/24 08:01 PM 0.9 75.6 22.48 31 -
04/06/24 09:01 PM 1.0 75.2 22.48 31 -
04/06/24 10:01 PM 0.9 75.2 22.50 31 -
04/06/24 11:01 PM 0.6 75.0 22.55 31 -
04/07/24 12:01 AM 1.0 74.8 22.55 30 -
04/07/24 01:01 AM 0.5 75.0 22.55 31 -
04/07/24 02:01 AM 1.3 75.2 22.56 31 -
04/07/24 03:01 AM 1.4 75.0 22.57 31 -
04/07/24 04:01 AM 1.5 75.2 22.58 31 -
04/07/24 05:01 AM 1.1 75.0 22.58 31 -
04/07/24 06:01 AM 1.2 75.0 22.59 30 -
04/07/24 07:01 AM 1.5 75.0 22.65 31 -
04/07/24 08:01 AM 1.2 75.2 22.62 31 -
04/07/24 09:01 AM 1.0 75.2 22.65 31 -
04/07/24 10:01 AM 1.6 75.2 22.65 31 -
04/07/24 11:01 AM 1.2 75.0 22.65 31 -
04/07/24 12:01 PM 1.2 75.0 22.66 31 -
04/07/24 01:01 PM 1.0 75.0 22.65 31 -
04/07/24 02:01 PM 1.5 75.2 22.61 31 -
04/07/24 03:01 PM 1.4 75.2 22.59 31 -
04/07/24 04:01 PM 1.9 75.2 22.61 31 -
04/07/24 05:01 PM 1.3 75.4 22.57 31 -
04/07/24 06:01 PM 2.3 75.4 22.60 31 -
04/07/24 07:01 PM 2.2 75.4 22.59 31 -
04/07/24 08:01 PM 2.1 75.4 22.58 31 -
04/07/24 09:01 PM 1.7 75.4 22.61 31 -
04/07/24 10:01 PM 2.4 75.2 22.60 31 -
04/07/24 11:01 PM 2.6 75.2 22.59 31 -
Test Result: PassTest Result: Pass
Test Location:Test Location: 430 W Hallam Aspen, CO 81611 Inspection Report Date:Inspection Report Date: 04/08/2024
Test device manufactured by SunRADON, LLC
Page 4 of 6
Radon Solutions, LLCRadon Solutions, LLC
Glenwood Springs, COLORADO 81601
970-987-9752
Test TableTest Table
* Data from first 4 hours excluded from EPA calculations
Date/Time Radon(pCi/l)Temp(F)Pres(inHg)Humidity(%)Flags
04/08/24 12:01 AM 1.9 75.0 22.63 31 -
04/08/24 01:01 AM 2.3 75.0 22.60 31 -
04/08/24 02:01 AM 1.7 74.8 22.61 31 -
04/08/24 03:01 AM 1.2 74.8 22.62 31 -
Test Result: PassTest Result: Pass
Test Location:Test Location: 430 W Hallam Aspen, CO 81611 Inspection Report Date:Inspection Report Date: 04/08/2024
Test device manufactured by SunRADON, LLC
Page 5 of 6
Radon Solutions, LLCRadon Solutions, LLC
Glenwood Springs, COLORADO 81601
970-987-9752
Radon Test InformationRadon Test Information
Radon Risk InformationRadon Risk Information
Radon causes lung cancer by means of the decay of its daughter products after breathing in air contaminated with higher
levels of Radon. The World Health Organization (WHO) estimates that 15% of lung cancers worldwide are caused by
exposure to elevated indoor levels of Radon. Overall, radon is the second leading cause of lung cancer responsible for
about 21,000 lung cancer deaths every year in the US alone. Radon gas is the number one cause of lung cancer among
non-smokers. The U.S. Environmental Protection Agency (EPA), the U.S. Surgeon General, and the Center for Disease
Control and Prevention (CDC) strongly recommend that ALL homebuyers have an indoor radon test performed prior to
purchase or taking occupancy and recommend having the radon levels professionally mitigated if elevated radon
concentrations are found.
Understanding Radon Test ResultsUnderstanding Radon Test Results
Recommended Action Levels vary by country and typically range from 3 pCi/l (100 Bq/m3) to 8 pCi/l (300 Bq/m3).
Recommendations below are based on test results by a Continuous Radon Monitor (CRM) Test of at least 48h duration
and are based on recommendations by the EPA.
Measured Average Radon Level:
At or above 4.0 pCi/l (148 Bq/m3): Corrective measures to reduce exposure to radon gas is strongly recommended
(ANSI MAH2014)
Between 2-4 pCi/l (74-148 Bq/m3): Consider mitigation or periodic retest as indoor Radon levels vary by season and
weather conditions
Below 2 pCi/l (74 Bq/m3): Consider bi-annual retest or whenever significant changes to the home structure or
mechanical systems occurred
Test Result: PassTest Result: Pass
Test Location:Test Location: 430 W Hallam Aspen, CO 81611 Inspection Report Date:Inspection Report Date: 04/08/2024
Test device manufactured by SunRADON, LLC
Page 6 of 6