HomeMy WebLinkAboutFile Documents.1419 Crystal Lake Rd.0113.2018 (7).ARBKAA.5A.75BCDEE.5FGH
2 11013
4
113 112A 112B 112C
2022
30
3'
-
9
3
/
4
"
4'
-
0
1
/
8
"
3'
-
5
1
/
2
"
3'
-
0
"
EG.
T
TT
T
T
3'
-
7
"
TOP OF FF @ LWR BASEMENT
+88'-10"
TOP OF FF @ MAIN BASEMENT
+89'-10"
TOP OF FF @ GUEST BEDROOM
+108'-4 1/2"
TOP OF FF @ UPPER LEVEL
+111'-7"
TOP OF FF @ MAIN LEVEL
100'-0"
TOP OF FF @ LIVING ROOM
98'-6"
TOP OF FF @ GARAGE
+99'-0"
T
T T
T
7'
-
1
1
"
2'
-
0
"
2'
-
0
"
MECHANICAL EXHAUST CHASE
TO MATCH FP CHIMNEYS
10
'
-
1
1
/
2
"
NEW ROOF OVER
GARAGE
LOWER GUEST
BEDROOM ON UPPER
LEVEL
PROPOSED TOPO
EXISTING TOPO
21
'
-
6
"
12
'
-
5
1
/
2
"
24
'
-
5
1
/
8
"
EXISTING ROOF
HEIGHTS 0F STRUCTURE
MANSARD HAS BEEN REMOVED
4'-0"
1
1
1
1
TOP OF FF @ MAIN BASEMENT
+89'-10"
2 1.5 133.544.556
5104
107
207A
210 21
31
3'
-
0
"
3'
-
5
1
/
2
"
T
T
T T
TOP OF FF @ UPPER FLOOR
+111'-7"
TOP OF FF @ MAIN LEVEL
100'-0"
TOP OF FF @ LIVING ROOM
98'-6"
TOP OF FF @ GUEST BEDROOM
+108'-4 1/2"
STAIRS BEYOND TO
MAIN LEVEL FLOOR LOWER
LIVING ROOM
2'
-
0
"
2'
-
0
"
EXISTING
TOPO
24
'
-
9
5
/
8
"
EXISTING ROOF
HEIGHTS / STRUCTURE
GAS METER
*EXISTING LOCATION
dimension is to regulator vent
centerline
4'-0"
3'-0"
GAS METER
*PROPOSED LOCATION
dimension is to regulator vent
centerline
6'-7"6'-5"
EXISTING GRADE
BACK FROM EXISTING STAIRS
PROPOSED GRADE
BACK FROM NEW STAIRS
1
1
PROJECT
SCALE
PROPOSED
ELEVATIONS
1/4" = 1'-0"
16019.00
A-201
DATE
05.26.2017 PERMIT
04.18.2018 CHANGE ORDER #1
COPYRIGHT 2017 THUNDERBOWL ARCHITECTS
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
2
7
3
7
1
8
1
3
2
0
1
7
14
1
9
C
R
Y
S
T
A
L
L
A
K
E
R
D
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
NORTH ELEVATION
1/4" = 1'-0"
1
A-201
EAST ELEVATION
1/4" = 1'-0"
2
A-201
DATE
PERMIT 05.26.2017
ASI #1 11.28.2017
04/23/2018
A A.5 A.75 B C D E E.5 F G H
H
104A10568
007A
008A
009
02 01
112E
206A
204B 26
28
TOP OF FF @ LIVING ROOM
98'-6"
1'
-
0
"
T
T
T
T
T
T
T
T
T
T
T T
T
T T
2'
-
0
"
2'
-
0
"
3'
-
1
1
/
2
"
3'
-
1
1
/
2
"
TOP OF FF @ MAIN BASEMENT
+89'-10"
TOP OF FF @ MAIN LEVEL
100'-0"
TOP OF FF @ UPPER LEVEL
+111'-7"
FIREPLACE VENT
*FOLLOW ALL MANUFACTURER
REQ'S AND CLEARENCES
LOWER
LIVING ROOM
EXISTING
TOPO
EXISTING ROOF
HEIGHTS OF STRUCTURE
MANSARD HAS BEEN REMOVED
4
A503
1
A503
2
A503
EXISTING ROOF
HEIGHTS OF STRUCTURE
MANSARD HAS BEEN REMOVED
204C
T
1
1
1 1.5 2 3 3.5 4 4.5 5 6
91011
107A
29
3'
-
6
1
/
4
"
1'
-
0
"
3'
-
3
"
T
T
6'
-
1
0
1
/
2
"
1'
-
0
"
TOP OF FF @ MAIN LEVEL
+100'-0"
TOP OF FF @ UPPER FLOOR
+111'-7"
TOP OF FF @ LOWER LEVEL
+89'-10"
EXISTING
TOPO
20
'
-
4
"
EXISTING ROOF
HEIGHTS / STRUCTURE
EXISTING ROOF
HEIGHTS OF STRUCTURE
MANSARD HAS BEEN REMOVED
TOP OF FF @ GUEST BEDROOM
+108'-4 1/2"
112D
T
T
32
PROPOSED TOPO
1 1
DATE
PERMIT 05.26.2017
ASI #1 11.28.2017
PROJECT
SCALE
PROPOSED
ELEVATIONS
1/4" = 1'-0"
16019.00
A-202
DATE
05.26.2017 PERMIT
04.18.2018 CHANGE ORDER #1
COPYRIGHT 2017 THUNDERBOWL ARCHITECTS
AS
P
E
N
,
C
O
L
O
R
A
D
O
PA
R
C
E
L
I
D
#
2
7
3
7
1
8
1
3
2
0
1
7
14
1
9
C
R
Y
S
T
A
L
L
A
K
E
R
D
C
TH
U
N
D
E
R
B
O
W
L
AR
C
H
I
T
E
C
T
S
THUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
SOUTH ELEVATION
1/4" = 1'-0"
1
A-202
WEST ELEVATION
1/4" = 1'-0"
2
A-202
04/23/2018