A. RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAM
Sheets showing snowmelt, pool, spa, and solar/GSHP information:
Do you have snowmelt or a spa that has been exempted by the buiding official?
Hydro Snowmelt Electric Snowmelt Pool Spa
Existing 726.00 sqft
To be Removed
Existing to Remain 726.00 sqft 0.00 sqft 0.00 sqft 0.00 sqft
New 1186.00 sqft
New (exempt)
Total on site 1912.00 sqft 0.00 sqft 0.00 sqft 0.00 sqft
Total Snowmelt on site
Boiler Efficiency 94.5%100%75.0% 75.0%
Mitigation Payment ‐$ ‐$
Total Payment for Mitigation:42,670.90$
B. ON-SITE RENEWABLE CREDITS
Supplemental System REMP Credit
Use PV Worksheet Photovoltaic System 43,518.99$
Use Thermal Worksheet Hot Water Panels -$
Use GSHP Cert Ground Source Heat Pump -$
Other Approved System -$
Total Mitigation Credits: 43,518.99$
Onsite Renewable Offsets: How many KiloWatts of PV (solar electric) would I need? 6.22
or How many square feet of SHW (solar hot water) would I need? 189.94
R-REMP Payment: -$
Amount Previously Paid on This Permit:3,860.42$
-$
Refund (includes minus $750): 3,110.42$
C. PREPARED BY:Date: 6/21/2020
Print Name:
Signature:
Phone & EMail:
REVIEWED:Date:
2015 IECC RESIDENTIAL RENEWABLE ENERGY MITIGATION PROGRAM
CITY OF ASPEN VERSION 11.2 UPDATED SEPTEMBER 12, 2017
210 S West End St
273718206004 0020-2020-BCHO
jleverson@galambosarchitects.net
Sheri Sack
429-1286 jleverson@galambosarchitects.net
TOTAL R-REMP PAYMENT:
Janet Leverson/Galambo Architects
1912.00 sqft
314D AABC
Janet Leverson
A-002
970-429-1286
Janet Leverson
$42,670.90
210 S west end
sherisack@vcaaspen.com
Yes (enter sqft below on the exempt row)No
06/30/2020
Justin Hahn 8/12/20
Parcel ID #:
Collector
Aspect,
Degress from
True South
Collector Tilt,
Degrees From
Horizontal
Solar
Orientation
Adjustment
Factor
DC side capacity
(kW)
Inverter capacity
(kW)
kW for
credit
kW Mitigation
Credit
Collector Group 1 51 18.4
93.70%4.48 4.48 4.48 4.20 kW
Collector Group 2 51 18.4
93.70%1.28 1.28 1.28 1.20 kW
Collector Group 3 129 18.4
73.58%1.28 1.28 1.28 0.94 kW
Collector Group 4 87.00%0 0.00 kW
Collector Group 5 87.00%0 0.00 kW
Collector Group 6 87.00%0 0.00 kW
Collector Group 7 87.00%0 0.00 kW
Collector Group 8 87.00%0 0.00 kW
Collector Group 9 87.00%0 0.00 kW
Collector Group 10 87.00%0 0.00 kW
Collector Group 11 87.00%0 0.00 kW
Collector Group 12 87.00%0 0.00 kW
Collector Group 13 87.00%0 0.00 kW
Collector Group 14 87.00%0 0.00 kW
Collector Group 15 87.00%0 0.00 kW
Collector Group 16 87.00%0 0.00 kW
Collector Group 17 87.00%0 0.00 kW
Collector Group 18 87.00%0 0.00 kW
Collector Group 19 87.00%0 0.00 kW
Collector Group 20 87.00%0 0.00 kW
Total: 6.34 kW
$ Mitigation Credit: 43,518.99$
Instructions:
1)
2)
3) DC side capacity is the total labled panel output kW in a group.
4) Inverter capacity is the recommended input power in kW of your inverter(s).
5)
6)
7)
8)
PREPARED BY:Date: 6/21/2020
Print Name:
Signature:
Phone & EMail:
REVIEWED:Date:
PV WORKSHEET
CITY OF ASPEN VERSION 11.2 UPDATED SEPTEMBER 12, 2017
Permit Number: 0305.2017.arbk273718206004
Enter the aspect and tilt for each group. The solar orientation adjustment factor is automatically
calculated.
PROJECT ADDRESS:
The mitigation credit will be automatically entered into your RREMP or CREMP form. If your project has both RREMP and
CREMP, it will automatically divide the credits up, with priority given to mitigating the CREMP payment.
Determine how many collector groups you have. Groups are used to differentiate between collectors
(panels) with different tilts, aspects, sizing, or inverters. If all your collectors are installed similarily, you
might have just one group.
210 South West End
Janet Leverson
Janet Leverson
429-1286 jleverson@galambosarchitects.net
The kW mitigation credit is totalled and multiplied by $6865.32/kW to get the $ Mitigation Credit
You will be given credit for the lesser of the labeled panel output or the inverter.