Loading...
HomeMy WebLinkAboutFile Documents.1320 Mountain View Dr.0013-2020-BCHO (20)Generated by REScheck-Web Software Compliance Certificate Project 1320 Mountain View Energy Code:2015 IECC Location:Aspen, Colorado Construction Type:Single-family Project Type:New Construction Orientation:Bldg. faces 0 deg. from North Conditioned Floor Area:4,790 ft2 Glazing Area 25% Climate Zone:7 (9922 HDD) Permit Date: Construction Site: 1320 Mountain View Aspen, CO Owner/Agent: 1320 Mountain View LLC 623 E Hopkins Ave Aspen, CO 81611 Designer/Contractor: Thunderbowl Architects 300 S Spring St Suite 201 Aspen, CO 81611 ryan@thunderbowlarchitects.com Permit Number: Compliance: Passes using UA trade-off 6.0% Better Than Code Maximum UA:722 Your UA:679 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA KITCHEN/DR Ceiling: Flat Ceiling or Scissor Truss 522 57.0 15.0 0.018 9 LR Ceiling: Flat Ceiling or Scissor Truss 633 57.0 15.0 0.018 11 BR Ceiling: Flat Ceiling or Scissor Truss 1,743 57.0 15.0 0.018 31 SOUTH LR Wall: Wood Frame, 16" o.c. Orientation: Unspecified 324 26.0 6.6 0.037 7 Door: Glass Door (over 50% glazing) Orientation: Unspecified 100 0.310 31 Window: Vinyl Frame Orientation: Unspecified 32 0.270 9 SOUTH LR Wall upstairs: Wood Frame, 16" o.c. Orientation: Unspecified 210 26.0 6.6 0.037 4 Door: Glass Door (over 50% glazing) Orientation: Unspecified 100 0.310 31 WEST Wall UPSTAIRS: Wood Frame, 16" o.c. Orientation: Unspecified 474 26.0 6.6 0.037 17 Window: Vinyl Frame Orientation: Unspecified 8 0.270 2 WEST Wall DNSTAIRS: Wood Frame, 16" o.c. Orientation: Unspecified 373 26.0 6.6 0.037 11 Window: Vinyl Frame Orientation: Unspecified 10 0.270 3 Project Title: 1320 Mountain View Data filename:Page 1 of 11 12/23/19Report date:01/27/2020 06/25/2020 bonniem Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Window copy: Vinyl Frame Orientation: Unspecified 54 0.270 15 WEST Wall garage UPSTAIRS: Wood Frame, 16" o.c. Orientation: Unspecified 124 26.0 6.6 0.037 5 north Wall UPSTAIRS: Wood Frame, 16" o.c. Orientation: Unspecified 262 26.0 6.6 0.037 7 Window: Vinyl Frame Orientation: Unspecified 6 0.270 2 Window copy: Vinyl Frame Orientation: Unspecified 66 0.270 18 north Wall DNSTAIRS: Wood Frame, 16" o.c. Orientation: Unspecified 221 26.0 6.6 0.037 4 Door: Glass Door (over 50% glazing) Orientation: Unspecified 87 0.310 27 Window: Vinyl Frame Orientation: Unspecified 9 0.270 2 Window copy: Vinyl Frame Orientation: Unspecified 9 0.270 2 WEST BEDROOM Wall: Wood Frame, 16" o.c. Orientation: Unspecified 203 26.0 6.6 0.037 8 MUDROOM: Wood Frame, 16" o.c. Orientation: Unspecified 40 26.0 6.6 0.037 1 Window: Vinyl Frame Orientation: Unspecified 8 0.270 2 UPSTAIRS EAST BEDROOM: Wood Frame, 16" o.c. Orientation: Unspecified 114 26.0 6.6 0.037 4 north LR Wall: Wood Frame, 16" o.c. Orientation: Unspecified 139 26.0 6.6 0.037 1 Door: Glass Door (over 50% glazing) Orientation: Unspecified 58 0.310 18 Window: Vinyl Frame Orientation: Unspecified 58 0.270 16 north DR Wall: Wood Frame, 16" o.c. Orientation: Unspecified 122 26.0 6.6 0.037 2 Door: Glass Door (over 50% glazing) Orientation: Unspecified 75 0.310 23 WEST DR Wall copy: Wood Frame, 16" o.c. Orientation: Unspecified 102 26.0 6.6 0.037 3 Window: Vinyl Frame Orientation: Unspecified 33 0.270 9 EAST LR Wall: Wood Frame, 16" o.c. Orientation: Unspecified 407 26.0 6.6 0.037 13 Door: Glass Door (over 50% glazing) Orientation: Unspecified 23 0.310 7 Window: Vinyl Frame Orientation: Unspecified 18 0.270 5 Window copy: Vinyl Frame Orientation: Unspecified 18 0.270 5 Floor: Slab-On-Grade (Unheated) Insulation depth: 0.5' 252 19.0 0.959 242 Basement: Masonry Block w/ Empty Cells Orientation: Unspecified Wall height: 6.8' Depth below grade: 6.8' Insulation depth: 6.8' 2,395 19.0 10.0 0.030 72 Project Title: 1320 Mountain View Data filename:Page 2 of 11 12/23/19Report date:01/27/2020 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Notes: Contractor:Steeplechase Construction 124 Totterdown Rd Aspen, CO 81611 Project Title: 1320 Mountain View Data filename:Page 3 of 11 12/23/19Report date:01/27/2020 Inspection Checklist Requirements: 100.0% were addressed directly in the REScheck software REScheck Software Version : REScheck-Web Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies?Comments/Assumptions 103.1, 103.2 [PR1]1 Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. Complies Does Not Not Observable Not Applicable Requirement will be met. 103.1, 103.2, 403.7 [PR3]1 Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. Complies Does Not Not Observable Not Applicable Requirement will be met. 302.1, 403.7 [PR2]2 Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_____ Cooling: Btu/hr_____ Heating: Btu/hr_____ Cooling: Btu/hr_____ Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 1320 Mountain View Data filename:Page 4 of 11 12/23/19Report date:01/27/2020 Section # & Req.ID Foundation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.2 [FO1]1 Slab edge insulation R-value.R-_____ Unheated Heated R-_____ Unheated Heated Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.2 [FO3]1 Slab edge insulation depth/length. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1 [FO4]1 Conditioned basement wall insulation R-value. Where interior insulation is used, verification may need to occur during Insulation Inspection. Not required in warm-humid locations in Climate Zone 3. R-_____ R-_____ R-_____ R-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [FO5]1 Conditioned basement wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.2.9 [FO6]1 Conditioned basement wall insulation depth of burial or distance from top of wall. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2.1 [FO11]2 A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.9 [FO12]2 Snow- and ice-melting system controls installed. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 1320 Mountain View Data filename:Page 5 of 11 12/23/19Report date:01/27/2020 Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.3.1, 402.3.3, 402.5 [FR2]1 Glazing U-factor (area-weighted average). U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.3 [FR4]1 U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.1.1 [FR23]1 Air barrier and thermal barrier installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.3 [FR20]1 Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.5 [FR16]2 IC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate ≤2.0 cfm leakage at 75 Pa. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.3.1 [FR12]1 Supply and return ducts in attics insulated >= R-8 where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. Complies Does Not Not Observable Not Applicable Exception: Ducts located completely inside the building envelope. 403.3.5 [FR15]3 Building cavities are not used as ducts or plenums. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.4 [FR17]2 HVAC piping conveying fluids above 105 ºF or chilled fluids below 55 ºF are insulated to ≥R- 3. R-_____R-_____Complies Does Not Not Observable Not Applicable Requirement will be met. 403.4.1 [FR24]1 Protection of insulation on HVAC piping. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.5.3 [FR18]2 Hot water pipes are insulated to ≥R-3. R-_____R-_____Complies Does Not Not Observable Not Applicable Requirement will be met. 403.6 [FR19]2 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 1320 Mountain View Data filename:Page 6 of 11 12/23/19Report date:01/27/2020 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 1320 Mountain View Data filename:Page 7 of 11 12/23/19Report date:01/27/2020 Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 303.1 [IN13]2 All installed insulation is labeled or the installed R-values provided. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.1.1, 402.2.5, 402.2.6 [IN3]1 Wall insulation R-value. If this is a mass wall with at least ½ of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-_____ Wood Mass Steel R-_____ Wood Mass Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [IN4]1 Wall insulation is installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 1320 Mountain View Data filename:Page 8 of 11 12/23/19Report date:01/27/2020 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.2.1, 402.2.2, 402.2.6 [FI1]1 Ceiling insulation R-value.R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.1.1, 303.2 [FI2]1 Ceiling insulation installed per manufacturer’s instructions. Blown insulation marked every 300 ft². Complies Does Not Not Observable Not Applicable Requirement will be met. 402.2.3 [FI22]2 Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 402.2.4 [FI3]1 Attic access hatch and door insulation ≥R-value of the adjacent assembly. R-_____R-_____Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.1.2 [FI17]1 Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. ACH 50 =_____ACH 50 =_____Complies Does Not Not Observable Not Applicable Requirement will be met. 403.3.4 [FI4]1 Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing Inspection. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable Exception: All ducts and air handlers are located within conditioned space. 403.3.3 [FI27]1 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer’s air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer’s air handler enclosure. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable Exception: All ducts and air handlers are located within conditioned space. 403.3.2.1 [FI24]1 Air handler leakage designated by manufacturer at <=2% of design air flow. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.1.1 [FI9]2 Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.1.2 [FI10]2 Heat pump thermostat installed on heat pumps. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.5.1 [FI11]2 Circulating service hot water systems have automatic or accessible manual controls. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 1320 Mountain View Data filename:Page 9 of 11 12/23/19Report date:01/27/2020 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.6.1 [FI25]2 All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.2 [FI26]2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.5.1.1 [FI28]2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.5.1.2 [FI29]2 Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.5.2 [FI30]2 Water distribution systems that have recirculation pumps that pump water from a heated water supply pipe back to the heated water source through a cold water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104ºF. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.5.4 [FI31]2 Drain water heat recovery units tested in accordance with CSA B55.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. Complies Does Not Not Observable Not Applicable Requirement will be met. 404.1 [FI6]1 75% of lamps in permanent fixtures or 75% of permanent fixtures have high efficacy lamps. Does not apply to low-voltage lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. 404.1.1 [FI23]3 Fuel gas lighting systems have no continuous pilot light. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 1320 Mountain View Data filename:Page 10 of 11 12/23/19Report date:01/27/2020 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 401.3 [FI7]2 Compliance certificate posted.Complies Does Not Not Observable Not Applicable Requirement will be met. 303.3 [FI18]3 Manufacturer manuals for mechanical and water heating systems have been provided. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: 1320 Mountain View Data filename:Page 11 of 11 12/23/19Report date:01/27/2020 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value 32.60Above-Grade Wall 29.00Below-Grade Wall 19.00Floor 72.00Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.27Window 0.31Door Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name:Date: Comments 01/27/2020