HomeMy WebLinkAboutFile Documents.124 W Hyman Ave.0051.2019 (26).ARBKPRODUCT DATA SHEET
SikaBond®-T100
ALL-IN-ONE HYBRID URETHANE ADHESIVE, MOISTURE VAPOR AND SOUND REDUCTION MEMBRANE
PRODUCT DESCRIPTION
SikaBond®-T100 is a one component, zero VOC,
permanently elastic, super strong, very low permeability,
moisture-cure, all-in-one hybrid polyurethane adhesive
that offers unlimited moisture protection, crack bridging
and sound reduction for full surface wood floor bonding.
USES
SikaBond®-T100 may be used for solid and engineered
wood floors (strips, longstrips, planks, panels, boards),
mosaic parquet, industrial parquet, wood paving
(residential) as well as chip boards and plywood. Once
cured, SikaBond®-T100 will generate a super strong
bond to a variety of substrates for glue down
installations and at the same time form a membrane
which reduces moisture vapor transmission from the
subfloor and sound reduction membrane.
CHARACTERISTICS / ADVANTAGES
150% Elongation▪
Bonds up to 3/4" solid and engineered wood▪
Cleans off prefinished floors before and after cure▪
Unlimited subfloor moisture vapor protection▪
No moisture testing required - a dry to touch substrate
is the only requirement
▪
ZERO VOC▪
Contains no water, solvent or isocyanates▪
Low moisture vapor permeability▪
Sound protection - meets local IIC and STC
requirements
▪
Crack Bridging▪
Very easy to spread▪
Low odor▪
Advanced Hybrid Technology▪
Excellent green grab▪
High elongation▪
Permanently elastic - allows planks to expand and
contract without damage to the adhesive
▪
Tenacious Bonding▪
Passes USGBC LEED Version 4▪
ENVIRONMENTAL INFORMATION
LEED EQc 4.1
( 100 g/L limit )
SCAQMD, Rule 1168
( 100 g/L limit )
passes passes
BAAQMD, Reg. 8, Rule 51
( 120 g/L limit )
LEED v4
( < 0.5 mg/m3 )
passes passes
APPROVALS / STANDARDS
Independently tested to - STC 62 (ASTM E-90) and IIC =
67 (ASTM E-492) when used as a sound control
membrane at the specified coverage.
PRODUCT INFORMATION
Chemical Base Hybrid Polymer
Packaging 4 gal. (15.14 L)
Color Off - white
Product Data Sheet
SikaBond®-T100
June 2019, Version 01.07
020512010000000039
1 / 5
10/14/2019
Shelf Life 12 months from date of production if stored in undamaged original sealed
containers
Storage Conditions Keep in dry conditions and protected from direct sunlight at temperatures
between 50 °F and 77 °F (10–25 °C)
Density 1.64 kg/L
Water Vapor Permeability is < 4 g/mmHg, 24h, m2 according to ASTM E-96
(< 4 Perms)
Consistency Easy to spread
TECHNICAL INFORMATION
Shore A Hardness 45–50 (7 days at 74 °F (24 °C) and 50 % R.H.)
Tensile Strength 150 psi (1.03 MPa)(7 days at 74 °F (24 °C) and 50 % R.H.)
Elongation at Break 150 %(7 days at 74 °F (24 °C) and 50 % R.H.)
Shear Strength 2.0 N/mm², 1 mm adhesive thickness (74 °F (24 °C) and 50 % R.H.)
Service Temperature -40–150 °F (-40–65 °C)
APPLICATION INFORMATION
Coverage
Coverage must be monitored to ensure accuracy of application. Trowel
angle may prevent proper coverage.
▪
Applicator is responsible for periodic inspection of the trowel to check for
excessive wear. Worn trowels must be replaced immediately.
▪
In case of uneven substrates, it may be necessary to use a notched trowel
with bigger notches (avert hollow sections).
▪
Coverage must be monitored to ensure accuracy of application. Trowel
angle may prevent proper coverage.
▪
Trowel size is recommended to obtain proper coverage larger sizes are
acceptable. Excessive amounts of adhesive may cause wood flooring to slide
while placing check coverage during installation.
▪
Product Data Sheet
SikaBond®-T100
June 2019, Version 01.07
020512010000000039
2 / 5
10/14/2019
P5 trowels should be used at 90° angle, SC+MB trowel or 1/4 in. (6.3 mm) x
1/4 in. (6.3 mm) V-notch at 45° angle to subfloor to get stated coverages.
▪
Substrate Quality: Structurally sound, clean, dry, homogeneous, even, free
from grease, dust and loose particles, paint, laitance, and other poorly
adhering particles must be removed.
▪
The P5 and SC+MB trowel are available from Sika.▪
Ambient Air Temperature Room temperature between 50 °F (15 °C) and 90 °F (35 °C). For ambient
temperatures standard construction guidelines should be followed. Follow all
wood floor manufacturers’ acclimation and room temperature requirements.
Relative Air Humidity Between 40 % and 70 % during installation is best for adhesive. See wood
floor manufacturer for wood requirements.
Substrate Temperature During laying and until SikaBond®-T100 has fully cured, substrate temperature
should be greater than 60 °F (15 °C) and in the case of radiant floor heating,
less than 70 °F (20 °C). For substrate temperatures, standard construction
guidelines should be followed.
Substrate Moisture Content For use as an adhesive only: SikaBond®-T100 is not affected by moisture or
vapor transmission. For protection of the wood, follow the wood floor
manufacturer’s requirements for subfloor moisture. If substrate is not
acceptable per wood manufacturer’s requirements, use SikaBond®-T100 at
recommended coverage rate for moisture protection or use Sika® MB.
For use as an adhesive and membrane: Concrete must be dry to touch.
Inspect for any wetness at base of drywall or visible signs of moisture on
concrete. Concrete and cement-based underlayments must be fully cured and
free of any hydrostatic and/or moisture problems. When properly applied in
accordance with Sika® guidelines, SikaBond®-T100 provides unlimited
moisture vapor protection.
Curing Rate Floor may accept light foot traffic after: 8 hours
Floor can be sanded after 18 hours.
Skin Time / Laying Time 60 min 74 °F 50 % R.H.
APPLICATION INSTRUCTIONS
SUBSTRATE PREPARATION
SikaBond®-T100 can be used without priming on
properly prepared, structurally sound concrete, cement
floors, chipboards, ceramic tiles, plywood and
hardwood. Sika® recommends the use of Sika® MB over
any dry, gypsum based subflooring to enhance surface
strength. Maximum acceptable floor variation is 3/16 in.
(4.7 mm) over 10 feet (3 m). Preparation is a critical step
in the installation process and will ensure a successful
long term tenacious bond. All concrete, cement screed
and gypsum based subfloors must be structurally sound,
clean, dry, smooth, free of voids, projections, loose
materials, oil, grease, sealers and other surface
contaminants. Remove laitance or weak areas
mechanically. For application over ceramic tiles it is
necessary to grind tile surfaces and clean thoroughly
with an industrial vacuum. For substrates with old well
bonded adhesive or adhesive residue use Sika® MB – see
Product Data Sheet for installation instructions and
proper details. If surface contains asphalt (cutback)
adhesive follow the Resilient Floor Covering Institute
“Recommended Work Practices” for removal. When the
asphalt (cutback) adhesive is sufficiently removed use
Sika® MB to help promote adhesion to the subfloor or
use a Sika Level system over the cutback residue.
SikaBond®-T100 will adhere to Sika® Level levelers and
patches as well as most common patching/leveling
compounds. For unknown substrates please contact
Sika® Technical Services for best practices at 1-800-933-
SIKA.
APPLICATION METHOD / TOOLS
Read and understand data sheet completely before
beginning installation. Follow all industry standards, as
well as hardwood and bamboo flooring manufacturer’s
recommendations for floor flatness, acclimation, design,
layout, application, etc. of wood flooring material. If
jobsite conditions are outside of flooring manufacturer’s
recommendations, take necessary corrective actions as
recommended by the floor manufacturer to address
these issues. Whether the moisture content of substrate
exceeds or is within the manufacturer’s
recommendations, to address current or possible future
subfloor moisture, apply SikaBond®-T100 as directed.
Product Data Sheet
SikaBond®-T100
June 2019, Version 01.07
020512010000000039
3 / 5
10/14/2019
SikaBond®-T100 is applied to the properly prepared
substrate directly from the pail and uniformly distributed
by trowel as described on this Product Data Sheet. Press
the wood floor elements firmly into the adhesive so that
the wood floor underside is sufficiently wetted. The
elements can then be joined together using a rubber
hammer and an impact block and/ or rubber mallet.
Many types of wood floors have to be tapped from the
top. Leave gaps at room perimeters and at any floor wall
partition to allow wood flooring to move naturally –
follow recommended guidelines from wood floor
manufacturer. Spacers should be used to ensure
perimeter space is maintained. The wood flooring
manufacturer’s laying instructions, acclimation
requirements, room humidity/environmental control
requirements as well as standard construction rules
must be observed.
Clean up
SikaBond®-T100 cleans easily off of most finishes on pre-
finished flooring, even after cure. It is still easier to clean
as you go while the adhesive is still wet. Clean with a soft
non-abrasive towel as you work. After cure remove
adhesive with a non-abrasive towel. Tools that will not
damage the floor finish may also work. Clean all tools
and equipment immediately after use before adhesive
cures. Mineral spirits or other similar solvent can be
used.
LIMITATIONS
Wood size limitations can be found in coverage section▪
P5 trowel or larger must be used with all solid woods
and when applying over gypsum based sub floor (for
use as an adhesive only)
▪
SC+MB or 1/4 in. (6.3 mm) x 1/4 n. (6.3 mm) trowel
must be used for use as an adhesive and vapor retarder
membrane. Follow the wood floor manufacturer’s
installation instructions.
▪
Periodically check coverage of adhesive during
installation: 100 % substrate coverage and adhesive
transfer is required to protect against damages from
subfloor moisture.
▪
Minimum age of concrete before application is 21–28
days, depending on curing and drying conditions.
▪
Room temperatures should be between 50 °F (10 °C)
and 90 °F (32 °C) during installation unless otherwise
specified limitations by wood flooring manufacturer.
▪
Do not use on wet, contaminated or friable substrates.▪
When needed, Sika® recommends the use of Sika®
Level patching and levelling compounds for best
results.
▪
Gypsum based sub-floors are very susceptible to excess
moisture and will be degraded if exposed to excess
moisture from below or above.
▪
Solid wood and bamboo flooring cannot be used below
grade due to their lack of dimensional stability.
▪
Do not use in areas subject to hydrostatic head or in
areas subject to secondary source of moisture.
▪
On-or below-grade substrates must have appropriate▪
vapor barrier (< 6 mil, 0.15 mm ) properly installed
below slab.
Do not use over concrete with curing compounds,
sealers or other surface treatments that could im pact
the adhesion.
▪
This adhesive will not prevent all possible moisture
related or installalation related issues such as im
proper acclimation of flooring, jobsite temperature and
relative humidity, etc.
▪
This membrane reduces moisture vapor emissions that
originate from below the membrane only.
▪
This membrane does NOT reduce issues originating
from the ends, sides or top of flooring, i.e. puddles,
water leaks, etc.
▪
Sub-floor should be level – do not use adhesive as a
levelling agent.
▪
Cutback or other asphaltic based residue must be
removed.
▪
Chemically treated woods (ammonia, wood stain,
timber preservatives, etc.) and woods with high oil
content must be tested for adhesion prior to
application.
▪
Adhesive should be kept above 60 °F (15 °C) for best
workability.
▪
Sufficient ambient moisture is necessary for proper
curing.
▪
When bonding solid wood Sika recommends the use of
straps to fully connect tongue and groove – especially
when wood pieces are not perfectly straight – ensure
starter rows are set and properly cured to handle
tension from straps.
▪
Installations over radiant heat require that slab
temperature be kept below 70 °F (21 °C) during
installation and for 48 hours after installation – then
raised slowly up to final desired temperature. Follow
wood floor manufacturer’s temperature guidelines.
▪
Do not expose SikaBond®-T100 to alcohol.▪
BASIS OF PRODUCT DATA
Results may differ based upon statistical variations
depending upon mixing methods and equipment,
temperature, application methods, test methods, actual
site conditions and curing conditions.
OTHER RESTRICTIONS
See Legal Disclaimer.
ENVIRONMENTAL, HEALTH AND SAFETY
For further information and advice regarding
transportation, handling, storage and disposal of
chemical products, user should refer to the actual Safety
Data Sheets containing physical, environmental,
toxicological and other safety related data. User must
read the current actual Safety Data Sheets before using
any products. In case of an emergency, call CHEMTREC
at 1-800-424-9300, International 703-527-3887.
Product Data Sheet
SikaBond®-T100
June 2019, Version 01.07
020512010000000039
4 / 5
10/14/2019
DIRECTIVE 2004/42/CE - LIMITATION OF EMISSIONS OF
VOC
0 g/L (measured per SCAQMD rule 1168)
LEGAL DISCLAIMER
• KEEP CONTAINER TIGHTLY CLOSED
• KEEP OUT OF REACH OF CHILDREN
• NOT FOR INTERNAL CONSUMPTION
• FOR INDUSTRIAL USE ONLY
• FOR PROFESSIONAL USE ONLY
Prior to each use of any product of Sika Corporation, its
subsidiaries or affiliates (“SIKA”), the user must always
read and follow the warnings and instructions on the
product’s most current product label, Product Data
Sheet and Safety Data Sheet which are available at
usa.sika.com or by calling SIKA’s Technical Service
Department at 1-800-933-7452. Nothing contained in
any SIKA literature or materials relieves the user of the
obligation to read and follow the warnings and
instructions for each SIKA product as set forth in the
current product label, Product Data Sheet and Safety
Data Sheet prior to use of the SIKA product.
SIKA warrants this product for one year from date of
installation to be free from manufacturing defects and to
meet the technical properties on the current Product
Data Sheet if used as directed within the product’s shelf
life. User determines suitability of product for intended
use and assumes all risks. User’s and/or buyer’s sole
remedy shall be limited to the purchase price or
replacement of this product exclusive of any labor costs.
NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL
APPLY INCLUDING ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY
LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL
DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE
USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON
ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY
RIGHTS HELD BY OTHERS.
Sale of SIKA products are subject to the Terms and
Conditions of Sale which are available at
https://usa.sika.com/en/group/SikaCorp/termsandcondi
tions.html or by calling 1-800-933-7452.
SikaBond-T100-en-US-(06-2019)-1-7.pdf
Sika Corporation
201 Polito Avenue
Lyndhurst, NJ 07071
Phone: +1-800-933-7452
Fax: +1-201-933-6225
usa.sika.com
Sika Mexicana S.A. de C.V.
Carretera Libre Celaya Km. 8.5
Fracc. Industrial Balvanera
Corregidora, Queretaro
C.P. 76920
Phone: 52 442 2385800
Fax: 52 442 2250537
Product Data Sheet
SikaBond®-T100
June 2019, Version 01.07
020512010000000039
5 / 5
10/14/2019