File Documents.200 S Aspen St.0007.2017 (78).ACBK
WWW.SDCSECURITY.COM ■ SECURITY DOOR CONTROLS Security Door Controls ACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM 1 MODELS HiTower® MOD 7500 SeriesFrame Actuator Controlled Lockset SDC can provide an SDC lockset with lever handles complete with the industry renowned HiTower® frame actu- ator (HiTower® Pro). Or you may send the lock body of your choice to SDC for conversion (HiTower® MOD). The HiTower® MOD series features the same benefits and application of the HiTower Pro, but adds the ability to retrofit the lock body of your choice. (see MODELS for lock compatibility) Mortise Lock Supplied by Distributor for modification A Falcon LM-561/MA581 (* Falcon - Distributor supplies faceplate)020100-000 D Sargent 8204 H Hager 3880 I Corbin/Russwin 2057 N Arrow B12 O Yale 7130F-L5 Exit Device P Yale 8805 R Schlage Retro (Replaces 5000 Series)L9080 S Schlage L9080 T Best 45H U Dorma M9000 V Marks 5EW Major Brand Electrified Lock Chassis, Less Trim, Provided by SDC Factory ZA Falcon ZD Sargent ZI Corbin Russwin ZN Arrow ZP Yale ZS Schlage ZT Best MAJOR BRAND MECHANICAL LOCK ELECTRIFICATION Arrow Best Corbin/Russwin Marks Falcon Dorma Sargent Hager Yale Falcon Cal Royal Schlage MEA City of New York 678-80-SA W ARRA N T Y YEAR5Meets NFPA 80 & 101for Life SafetyAll trademarks are property of their respective owners.9/26/17 SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM Security Door Controls ACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM2 • High-rise stairwell doors • Elevator lobby doors • Perimeter exit doors • Hospital communicating bathroom • Office doors • Computer rooms • Equipment rooms • Pharmacy storage rooms • Money counting rooms • Security and safety mantraps APPLICATIONS COMPETITIVE LOCK COMPARISON CHART SDC - HiTower®ACSI - Gemini Corbin/Russwin FAILSAFE 7530 8500-M2-PL ML22960 ML22907 7550 8500-M1-PL ML22950 ML22905 FAILSECURE 7560 8500-M2-PUL ML22980 ML22909 7570 8500-M1-PUL ML22970 ML22908 OPTIONS SC-10 QC L SPDT (Latch Status only) S SPDT (Latch & Deadlock Status)CLS Closed loop only (SPDT not available) MORTAR GUARD 7500EB-S (1.75” - 2” Face Frames)302-03-02 7500EB-N (1.25” - 1.5” Face Frames)303-03-04 9/26/17 WWW.SDCSECURITY.COM ■ SECURITY DOOR CONTROLS Security Door Controls ACCESS & EGRESS SOLUTIONS - THE LOCK BEHIND THE SYSTEM 3 7530 / 7560 7550 / 7570 Recommended for Fire Life Safety Applications. Unlocked by power loss or signal from the fire life safety system. See SDC power supplies with fire life safety system interface for release of locks in an emergency. 7530 LOCKED FROM BOTH SIDES Locked when energized, unlocked by an access control, remote control or a key from either side (SEE FIG. 1). Suggested use: Openings that are to be locked on both sides, such as: communicating doors; inner offices; safety mantraps. 7550 LOCKED OUTSIDE ONLY, FREE EGRESS FROM THE INSIDE Locked when energized, unlocked by an access control, key from the outside. Uninhibited egress at all times by rotating the inside lever (SEE FIG. 2). Suggested use: Stairwell doors, lobby doors, exit doors, inner offices, safety mantraps, communicating bathrooms. Recommended for High Security Applications. Power loss causes doors to lock. See SDC power supplies for continued operation during power failures. (SDC and Schlage only) 7560 LOCKED FROM BOTH SIDES Locked when de-energized, unlocked by an access control, remote control or a key from either side (SEE FIG. 1). Suggested use: Openings that are to be locked on both sides, such as: communicating doors, inner offices, security mantraps. 7570 LOCKED OUTSIDE ONLY, FREE EGRESS FROM THE INSIDE Locked when de-energized, unlocked by an access control, key from the outside. Uninhibited egress at all times by rotating the inside lever (SEE FIG. 2). Suggested use: Inner offices, computer rooms, equipment or storage rooms, cashier rooms, security mantraps. FAILSAFE - POWER TO LOCK FAILSECURE - POWER TO UNLOCK LOCK FUNCTION Locked when de-energized, the failsecure mode is recom- mended for security applications. Such as, inner offices, equipment rooms and security mantraps. Loss of power causes all doors to lock. Battery back-up is required for continued operation during a power loss. Locked when energized, the failsafe mode is recommend- ed for fire life safety applications. Such as, stairwell doors, perimeter exit doors and safety mantraps. Loss of power or a signal from the life safety system causes all doors to unlock for free uninhibited access and egress. Fig. 1 Fig. 2 SPECIFICATIONS Grade ANSI 156.13 Grade 1 Backset 2.75” Min. Door Thickness 1.75” Weight 7.0 lbs Electrical .5 Amp @24VDC; .5 Amp @ 24VAC; .2 Amp @115Vac Standard Frame Actuator Strike Prep Dimension Standard ANSI 4-7/8” x 1-1/4” Face Frame Thickness 1-3/4” to 2” Narrow Frame Actuator Strike Dimension 8-1/2” x 1-1/4” Face Frame Thickness 1-1/4” to 1-1/2” Failsecure Actuator Strike Dimension SDC Z/ZR7560, Z/ZR7570: 4-7/8” x 1-1/4” Schlage ZS7560, ZS7570: 5-3/4” x 1-1/4” Face Frame Thickness 2” 9/26/17 © 2017 SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM Security Door Controls LIT-7500 SERIES HITOWER MOD 01/17 [t] 800.413.8783 ■ 805.494.0622 ■ [f] 866.215.3138 ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011 1| SPECIFY MODEL HOW TO ORDER 7530 Locked Both Sides, Failsafe 7550 Locked Outside Only, Failsafe 2| SPECIFY FUNCTION 4| SPECIFY ACTUATOR VOLTAGE STANDARD FAILSAFE ACTUATORS For 1.750” to 2” face frames. A 115VAC B 24VAC C 24VDC NARROW FAILSAFE ACTUATORS For 1.25” to 1.5” face frames. Special strike preparation required. D 115VAC E 24VAC F 24VDC C 605 Bright Brass D 606 Dull Brass F 611 Bright Bronze G 612 Dull Bronze H 613 Oil Rubbed Bronze P 625 Bright Chrome Q 626 Dull Chrome (Standard) S 629 Polished Stainless U 630 Dull Stainless 5| SPECIFY FINISH Major Brand Electrified Lock Chassis, Less Trim, Provided by SDC Factory ZS Schlage ZD Sargent ZP Yale ZA Falcon ZN Arrow ZT Best ZI Corbin Russwin Mortise Locks Supplied by Distributor Distributors supply SDC with the mortise lock body and armored front (less trim) for modifica- tion. SDC returns the modified lock body with an electric actuator. Upon installation, two lever return spring cages (supplied by distributor) are required for proper operation. 3| SPECIFY HAND L Left Hand LR Left Hand Reverse R Right Hand RR Right Hand Reverse Right Hand "RH" Left Hand "LH" (OUTSIDE) Left HandReverse"LHR" Right HandReverse"RHR"(OUTSIDE) LOCK STATUS AND WIRE HARNESS L Latch Status Switch, SPDT 3 Amps @ 30VDC S Latch and Deadlock Status 3 Amps @ 30VDC SC-10 Socket Connectors with 10 ft. Cable, Power Wiring Only SC-10-5 Socket Connectors with 10 ft. Cable for Power and Options SPECIAL STRIKES SSP Special Retrofit Strike Plate MORTAR GUARD ELECTRIC BACK BOXES FOR FRAME ACTUATORS WITH CONDUIT KNOCKOUTS 7500EB-S For Standard Actuators in 1-3/4” or 2” Face Frames 7500EB-N For Narrow Actuators in 1-1/4” or 1-1/2” Face Frames 7560EB-2 For Failsecure Actuators Installed in 2” Face Frames 6| SPECIFY ADD-ONS: (OPTIONAL) PRODUCT SKU SAMPLE: S 7550 LR C Q SC-10 A Falcon LM-561/MA581 (* Falcon - Distributor supplies face- plate) 020100-000 D Sargent 8204 H Hager 3880 I Corbin/Russwin 2057 N Arrow B12 O Yale 7130F-L5 Exit Device P Yale 8805 R Schlage Retro (Replaces 5000 Series) L9080 S Schlage L9080 T Best 45H U Dorma M9000 V Marks 5EW 9/26/17