Loading...
HomeMy WebLinkAboutFile Documents.200 S Aspen St.0007.2017 (79).ACBKPROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com Load Controls Allows control of any room or device with a single button• Acts as a stand-alone, self-contained dimmer or as a fully • programmable keypad on the Vantage system Controls loads in secondary structures such as a pool house, detached • garage, shed, etc Additional control with a built-in IR receiver• Provides LED button lighting with adjustable brightness levels• Offers same look and feel as other Vantage keypad stations• Available in 1 or 2 load (gangs) configurations• May be ganged with other ScenePoint stations up to 4 gangs• Available in 3 or 5 button configurations• The Vantage ScenePoint Dimmer is a standard wall box dimmer that also connects to the Vantage system. It is powered by the local line feed, and replaces a standard high voltage wall switch. ScenePoint dimmers feature a maximum load of 5A (600W @ 120V) / 5A (1200W @ 240V) per single gang and connects to high voltage wiring within the box for local lighting control. ScenePoint Dimmers also connect to the Vantage system with two-way communication for centralized control of the lighting circuit via the traditional two-wire station bus. ScenePoint dimmers fit the needs of any new construction or expansion projects. Either way, ScenePoint dimmers allow for incremental expansion of a system to accommodate almost any design or budget. Stations may be ganged together up to four gangs. EASYTOUCH II SCEnEPOInT DImmEr Product Highlights PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com EasyTouch II ScenePoint Dimmer Specifications Height, All Gangs 4.3” (109mm) One Gang Width 2.5” (64mm) Two Gang Width 4.3” (109mm) Depth, All Gangs 1.38” (35mm) Model DSXxxx-Xxxx Weight 4.9 oz (139g) (1-gang) 8 oz (227g) (2-gang) Voltage 120/240V ~ 60/50Hz Ambient Operating Humidity 5 - 95% non-condensing Ambient Operating Temperature 32 - 95°F (0 - 35°C) Arc Suppression Zero cross built-in arc suppression Auto LED Intensity Yes, Built-in/standard Backlit Buttons 3 color LEDs Built-in Lightning/Surge Protection - High Voltage MOV surge suppression - High Voltage meets IEEE C62.41 (6000V & 3000A) Built-in Lightning/Surge Protection - Low Voltage MOV surge suppression - Low Voltage meets ITU-T K.20 Cooling None required IR Receiver Yes, Built-in/standard Load Types Incandescent, Magnetic Low Voltage, forward phase Fluorescent dimming ballasts, non-dimmable fluorescent ballasts (relay mode only), Neon, Cold Cathode (lpf), and HID Maximum Load 5A (600W @ 120V) -or- 5A (1200W @ 240V) Minimum Load Required 15W Safety Off Switch Load by Load selectable Station Bus 24V / 36V Station Bus Station Bus Specification 2C 16AWG, non-shield, <30pF per foot - Station Bus should be separated a minimum of 12” from other parallel communication and/or high voltage runs Station Equivalent 0.36W on IC-24 / 0.54W on IC-36 Station Wiring Configuration Daisy-chain/Star/Branch Status Indicator Microprocessor Status LED UL and CUL Listed Yes General Specifications Dimensions, HWD InFusion System Compatibility SIDE VIEW BACK VIEWFRONT VIEW 4.3" 2.5"1.375" 1.25" LINE LOAD NEUT OREM, UTAH CLASS 2 Station Bus Wire Channel Built-in Light and IR Sensor Service/Bulb Replacement Switch PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com • True type font laser engraved button text • Full range RGB adjustable backlight for buttons • Hidden ambient light sensor for automatic day/night backlight intensity control* • Hidden built-in IR receiver* • Responds instantly to button press regardless of system size • Accepts multi-event programming on a single button • Uses the standard Vantage two-wire, non-polarized station bus • Compatible with 24-volt or 36-volt station bus • Stations are compatible with Clip-loc or Clip-loc II faceplate fastening • Built-in surge suppression • Available in metal or plastic painted faceplates EASYTOUCH II STANDARD KEYPAD STATION The EasyTouch II keypad joins Vantage’s premier line of backlit keypad stations. Used to replace multiple conventional switches, Vantage keypads allow users to experience stylish, single-button control of their home. Available in one through five-button configurations, EasyTouch II adds both enhanced functionality and sleek, sophisticated design to the offering. It features full-range RGB backlighting with a built-in diffuser. The backlight color indicates the status of the programmed button by providing the user with the option to personalize the color for ON and OFF status. And, due to Vantage’s use of laser engraving, only the lettering on each button will be illuminated, rather than the full button. EasyTouch II also features a hidden ambient light sensor for automatic day/night backlight intensity control*, as well as an IR receiver* for convenient remote control of the keypad. * Excludes single button versions Product Highlights User Interfaces PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com SIDE VIEW BACK VIEWFRONT VIEW 2.75" 0.9" 4.125" 2.312" 1.75" 1.9" UP EasyTouch II Standard Keypad Station Specifications 4.125” x 2.30” x 0.9” 105mm x 58mm x 23mm Models KSxxxx-xxxx Weight 1.8 oz (51g) Ability to Gang with Conventional Switches Yes (see NEC code book for proper installation of Class 2 and line voltage connections) Addressing Self-addressing through software IR Receiver Yes, Built-in/standard Ambient Light Sensor Yes, Built-in/standard Ambient Operating Temperature 32-95°F (0-35°C) Ambient Operating Humidity 5-95% non-condensing Button LED RGB, full color Button Configurations 1 - 5 Buttons Color Options Arctic White (AW), Vantage Ivory (VI), Black (BK), Original Bronze (OB) and Titanium (TI) Maximum Number of Gangs Up to 4 gangs Sound Yes (variable pitch) Status LED Microprocessor status LED blink pattern Surge Suppression Yes UL, CUL and CE Listed Yes General Specifications Dimensions, HWD REV 0 InFusion Auxiliary Connections 2 Outdoor Use (1 or 2 Gangs Only) With approved Weatherproof Cover (Part# WPC-1 or WPC-2) Power for External Devices 15mA @ 12V DC Quxiliary Wiring Connection 2 Wire 600V Pigtail (included) Station Bus Connection 2 conductor, 16 AWG stranded, non-shield, <30 pF/foot - Station Bus should be separated a minimum of 12” from other parallel communication and/or high voltage runs Station Wiring Configuration Daisychain/Star/Branch Station Equivalent 24V 3 Buttons count as 0.6Watts, 5 Buttons count as 0.72Watts Station Equivalent 36V 3 Buttons count as 0.9Watts, 5 Buttons count as 1.08Watts System Compatibility Wiring Specifications 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com • 4.3” LCD panel with projected capacitive touch interface • Titanium TrimLine II frame, black glass-to-edge surface aesthetic • Unique mini graphical user interface aesthetically identical to other Equinox devices • Ambient light sensor for auto day/night backlighting • Active IR sensors for approach On and Auto sleep modes • Up to four possible mini widgets; comfort, lighting, audio, clock/weather • Powered by InFusion • Connected via station bus • Uses standard US and European single-gang wall box mechanics • Dynamically updated • Low power consumption • Tap, swipe, press and hold to navigate EQUINOX 40 LCD KEYPAD With a minimalistic on-wall presence, the Equinox 40 LCD keypad maintains a signature Vantage aesthetic while delivering complete room control through a unique single layer programmable interface. This revolutionary LCD keypad simplifies control of lighting, audio and climate in a single-gang form factor. The Titanium frame and black glass to edge surface aesthetic blends to any decor and provides a harmonious on-wall design consistent with Equinox touchscreens & apps as well as other keypads, wiring and connectivity devices. The keypad station is connected to the Vantage system via Vantage station bus. Sized and positioned as a standard light switch, Equinox 40 delivers the equivalent control of up to 9 keypad station buttons plus audio and climate control. The backlit 4.3” LCD panel has an auto presence detection and auto dim to OFF power saver mode with immediate ON and quick to control access when presence is detected. Utilizing the power of Vantage’s Design Center software, Equinox 40 includes up to 4 possible mini widget combinations with an auto- configuration capability that allows Integrators to efficiently create intuitive screens that are consistent with the entire Equinox family of products. Audio and climate mini-widgets provide an environment that eliminates the need for additional wall mounted hardware. In addition to the “home” page two additional pages can be revealed by flicking left/right. Pages can be set as additional time of day lighting scenes, personalized to different users, or set by activity (shades, lighting, pool/spa, etc.). Much more flexible than a standard keypad yet carrying the same footprint, Equinox 40 combines a quick view of lighting, comfort and audio with two additional pages for further control opportunity revealed by gesturing left or right. Its glass screen automatically adjusts to the lit space. Product Highlights User Interfaces EQ40TB-TI PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com TOP WIDGET AREA - Comfort/Climate/Clock/Blank/Weather Provides relevant thermostat, weather or clock information MIDDLE WIDGET AREA - Scenes Provides standard button control and feedback for any scene Supported Button Count - Max three per page with audio, max five per page without audio BOTTOM WIDGET AREA - Audio Provides single zone audio control for power, volume, source selection, transport commands, streaming and other services Equinox 40 LCD Keypad Specifications On-Wall Surface 4.9” x 3.44” x 0.44” (124mm x 87mm x11mm) Overall 4.9” x 3.44” x 1.38” (124mm x 87mm x 35mm) Model EQ40TB-TI Hard Buttons 1 Home, 1 Programmable Display Active Matrix Color LCD Size 4.3” Diagonal Colors 16 Bit Color Wiring Connections 2 Wire 600V Pigtail (Included) - 6 Wire Aux. Pigtail (Ordered Separately) Operating Temperature 32°F - 95°F (0°C - 35°C) Ambient Operating Humidity 5-95% Non-condensing Certification CE, RoHS General Specifications Dimensions, HWD REV 0 InFusion System Compatibility Mini Widget Combinations Equinox 40 has three mini widget areas: The top, middle and bottom of the LCD keypad 4.9"2.63" .44" 3.44" FRONT VIEW BACK VIEW SIDE VIEW TO P VIEW 1.38" 1.68" 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com • Increased processor speed, RAM and Flash Memory • Three times faster firmware updating • Backup micro SD card • Automatic backups of all configuration each week • Password protection • Remote firmware updating • Email notification support for Yahoo, Gmail, Hotmail, and more • Ethernet enabled; right angle Ethernet jack • Auto addressing (ZeroConf) • 5 RS-232 ports; 2 RS-485 ports • 120 low voltage stations; 120 wireless stations • Tracks real and astronomical time • Supports up to seven enclosures per controller • 24VDC and 36VDC versions • Not compatible with IC-1 controllers INFUSION CONTROLLER II The InFusion Controller II (IC-24-II and IC-36-II) replaces the current InFusion Controller (IC-1) and offers a wide variety of benefits over the now replaced IC-24-1 and IC-36-1. IC-II with increased processor speed, RAM, and flash memory meets the demand for delay-free control of large, complex systems. One InFusion Controller can support up to 120 WireLink stations and up to 120 RadioLink stations. Controllers can easily network to expand the system to 31 controllers. Five RS-232 and two RS-485 ports provide easy device connectivity while an Ethernet connection supports IP connected products. With Equinox, commercial and residential applications will have a variety of controlled subsystems, including lighting, audio/video, security, climate control, etc. The InFusion Controller provides seamless integration of those subsystems—enhancing the entire control experience. See system compatibility notes for legacy controller compatibility. Product Highlights Controllers PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com InFusion Controller II Specifications 6.62” x 7.88” x 3.0”” 168mm x 200mm x 76mm Model IC-36-II and IC-24-II Ambient Operating Humidity 5-95% non-condensing Ambient Operating Temperature 0-40°C / 32-104°F Cooling Convection Dimensions HWD 6.62” x 7.88” x 3.0” (168mm x 200mm x 76mm) Lithium Battery Backup Disk battery CR2032, 3Volt 2.5 yrs. un-powered or 20 yrs. powered (field replaceable – see caution at end) Max. # WireLink Stations IC24-1 Up to 50 Stations each bus or until the shared 35W supply is used Max. # WireLink Stations IC36-1 Up to 60 Stations each bus or until the independent 60W supply is used on each bus Max. Length of Each Controller 2000 feet / 609 meters-Vantage spec. wire 1000 ft / 304 meters-CAT5 wire to Controller Bus Network Max. Wire From IC to SC 200 feet / 61 meters Max. Wire Length Station Bus 2,000 feet of cabling max. on each station bus. No station more than 1,000 feet from Controller Maximum Power Draw 200W Minimum Power Draw 6W Station Bus Power Supply, IC-24-1 One 35W shared power supply to both station buses Station Bus Power Supply, IC-36-1 One 60W independent power supply to each station bus Station Bus Specification 2C 16AWG, non-shield, <30pF per foot Station Bus should be separated a minimum of 18” from other parallel communication and/or high voltage runs Voltage 120-240V, 50/60Hz Weight 3.3 lbs -or- 1.5kg Wire Configuration of Station Bus Daisy Chain, Branch, Star Wiring config. C2C, IC Network Daisy Chain Lightning / Surge Protection Static Shock IO. All ports and case, IEC 61000-4-2, Low Voltage, ITU-T K.20 UL, CUL and CE Listed Yes It is important to note that you are unable to mix IC-1 and IC-II controllers on the same project. In order to upgrade an existing customer to the latest controller, you must replace all controllers on the project. General Specifications System Compatibility Dimensions, HWD REV 1 manualoverride FRONT VIEW SIDE VIEW BACK VIEW 2.06" 7.88" 4.56" Control Locking Screw 3" 6.62" Mounting Post Lithium Battery 9.25" Mounting Post Connection Ports 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com • Houses one main controller and up to two (IMPE-2) or four (IMPE-4) modules • Features plug-and-play fittings for all modules • Boasts an opening in the panel door providing easy access to the controller • Comes factory installed with a low-voltage wiring harness eliminating the need to wire between modules • Installs between standard 16-inch/40.64-centimeter on center framing or may be surface mounted • Custom fitted hinged door for recessed or surface installs • Allows visual diagnostics of enclosure components through ventilation slots in the cover • Enclosure Terminal Boards are available for new modules as well as legacy modules • Terminal boards must be specified when ordering - When terminal boards are ordered separately, they include dedicated screw-terminal conductors for line feed and load attachment INFUSION MAIN POWER ENCLOSURE - IMPE The InFusion Main Power Enclosure (IMPE) is a key component of Vantage’s lighting control centralized solution. The IMPE houses the InFusion Controller and up to four separate control modules. The InFusion control modules that mount in the IMPE include standard, electronic and low voltage dimming and relay control. Each enclosure features new module locking mechanisms for improved in-field plug and play installation and service; allowing modules to be quickly replaced without affecting load connections to the system. Available in two or four module configurations layout of the IMPE is simply designed through Vantage Design Center Software. The enclosure is capable of supporting current modules and is forward compatible with Vantage’s future enhanced modules. The four module (IMPE-4) has the capacity for 32 line feeds and up to 256 amps. Designed for efficient field installation, the enclosure is easily mounted between 16” o.c. studs. Electrical compatibility includes 120 - 277 VAC and 50 or 60 Hz. It has a custom fitted hinged door for recessed or surface installs to give installers easier access to the controllers and modules. Product Highlights Infrastructure & Enclosures PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com InFusion Main Power Enclosure - (IMPE-2 / IMPE-4) Specifications Model InFusion IMPE-2-IC36 IMPE-4-IC36 IMPE-2-IC24 IMPE-4-IC24 35” x 14.5” x 4” 52” x 14.5” x 4” 88.9cm x 37cm x 10cm 132cm x 37cm x 10cm Weight 29 lbs (13.1 kg) 42 lbs (19.1 kg) Number of Modules Up to 2 Up to 4 Line Feed Terminals Up to 16 Up to 32 Load Terminals Up to 24 Up to 48 Neutral Terminals Up to 33 Up to 65 Ground Bar Terminals Up to 36 Up to 72 Electrical Compatibility 120-277 VAC, 50/60 Hz 120-277 VAC, 50/60 Hz Pre-assembled Yes (Less Module terminal boards) Yes (Less Module terminal boards) Cover Vented, hinged Vented, hinged Ambient Operating Temperature 0–40° C (32–104° F) 0–40° C (32–104° F) Ambient Operating Humidity 5–95% non-condensing 5–95% non-condensing Wire Copper wire only Copper wire only Wire Insulation (minimum) 80° C (176° F) 80° C (176° F) Ventilation Maintained 36” frontal clearance Maintained 36” frontal clearance UL, CE and CUL listed Yes Yes InFusion General Specifications System Compatibility Dimensions, HWD 4” 52” 35” 14.5” TOP VIEW IMPE-4 FRONT VIEW IMPE-2-IC FRONT VIEW SIDE VIEW 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com • Extends the Main Controller’s load capacity • Features plug-and-play fittings for all modules • Comes factory installed with a low-voltage wiring harness eliminating the need to wire between modules • Installs between standard 16-inch/40.64-centimeter on center framing or may be surface mounted • Custom fitted hinged door for recessed or surface installs • Allows visual diagnostics of enclosure components through ventilation slots in the cover • Enclosure Terminal Boards are available for new modules as well as legacy modules • Terminal boards must be specified when ordering - When terminal boards are ordered separately, they include dedicated screw-terminal conductors for line feed and load attachment INFUSION SECONDARY POWER ENCLOSURE - ISPE The InFusion Secondary Power Enclosure (ISPE) is a key component of Vantage’s lighting control centralized solution. The ISPE economically extends the load capacity of the Vantage System, extending system capacity from the Main Power Enclosure (IMPE). Up to six Secondary Enclosures can be connected to one Main Power Enclosure and thereby one InFusion Controller. This adds up to an additional 288 loads for a single Controller. Each enclosure features new module locking mechanisms for improved in-field plug and play installation and service; allowing modules to be quickly replaced without affecting load connections to the system. Available in two or four module configurations, layout of the ISPE is simply designed through Vantage Design Center Software. The enclosure is capable of supporting current modules and is forward compatible with Vantage’s future enhanced modules. The four module ISPE has the capacity for 32 line feeds and up to 256 amps. Designed for efficient field installation, the enclosure is easily mounted between 16” o.c. studs. Electrical compatibility includes 120 - 277 VAC and 50 or 60 Hz. It has a custom fitted hinged door for recessed or surface installs to give installers easier access to modules. Product Highlights Infrastructure & Enclosures PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com InFusion Secondary Power Enclosure - (ISPE-2 / ISPE-4) Specifications Models - InFusion ISPE-2-IC ISPE-4-IC 35” x 14.5” x 4” 52” x 14.5” x 4” 88.9cm x 37cm x 10cm 132cm x 37cm x 10cm Weight 29 lbs (13.1 kg) 42 lbs (19.1kg) Number of Modules Up to 2 Up to 4 Line Feed Terminals Up to 16 Up to 32 Load Terminals Up to 24 Up to 48 Neutral Terminals Up to 33 Up to 65 Ground Bar Terminals Up to 36 Up to 72 Electrical Compatibility 120-277 VAC, 50/60 Hz 120-277 VAC, 50/60 Hz Pre-assembled Yes (Less Module terminal boards) Yes (Less Module terminal boards) Cover Vented, hinged Vented, hinged Ambient Operating Temperature 0–40° C (32–104° F) 0–40° C (32–104° F) Ambient Operating Humidity 5–95% non-condensing 5–95% non-condensing Wire Copper wire only Copper wire only Wire Insulation (minimum) 80° C (176° F) 80° C (176° F) Ventilation Maintained 36” frontal clearance Maintained 36” frontal clearance UL, CE and CUL listed Yes Yes InFusion General Specifications System Compatibility Dimensions, HWD 4” 52” 35” 14.5” TOP VIEW ISPE-4-IC FRONT VIEW ISPE-2-IC FRONT VIEW SIDE VIEW 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com • Supports control of up to 12 loads • Plug-and-play design • Eliminates the need for field wiring to the module • Can notify dealer or end user of problem by email • Enhanced support for AFCI breakers • Includes fuses to protect the module • Includes two additional fuses for spares • Current sensing for energy management applications • Firmware is field upgradeable • Step free ramping and dimming • Displays the operating and fuse status with LED indicators • Protects against current and thermal overload • Self-powered design for uninterrupted lighting during servicing • Offers load by load selectable override control • Allows manual overrides to be programmed to any dim level STANDARD DIMMING MODULE (SDM12-EM) The InFusion Standard Dimming Module (SDM12-EM) is a key component of Vantage’s centralized lighting control. The SDM12-EM is mounted in a Main or Secondary Power Enclosure (IMPE or ISPE) and supports control of up to 12 standard (forward phase) loads with up to four line feeds and up to 64 total amps of load. Enclosures and module provide new module locking mechanisms for improved in-field plug and play installation and service; allowing modules to be quickly replaced without affecting load connections to the system. Field Serviceability is enhanced with field service alerts sent via email to installers and the industries first in-field firmware upgradable lighting control modules. Layout of the Dimming Module is simply designed through Vantage Design Center Software. The two additional line feeds provide added flexibility with AFCI circuit breakers compared to previous generation models. The modules have current sensing built-in allowing enhanced conditional programming in Design Center for increased support of Energy Management scenarios. SDM12-EM series modules provide exceptional support of LED and CFL low wattage lighting (5W@120V / 12W@277V) as well as high wattage lighting loads. The SDM12-EM module is compatible with new and old enclosures using new AC terminal boards. Electrical specifications include the SDM12-EM having a single part number that supports 120- 277 VAC and 50 or 60 Hz for global compatibility. Product Highlights Load Controls PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com Standard Dimming Module (SDM12-EM) Specifications 7.63” x 9.44” x 3.75” 194mm x 240mm x 95mm Model SDM12-EM Voltage 120V-277V ~ 60/50Hz Maximum Amperage per Module 64A (7680W@120V) 64A (17,728W@277V) Maximum Individual Load Amperage 16A (1920W @ 120V) 16A(4432W@277V) Maximum Transformer Load 1000VA@120V 2300VA@277V Weight 5.7 lbs (2.6 kg) Ambient Operating Humidity 5 - 95% non-condensing Ambient Operating Temperature 32 - 104°F (0 - 40°C) Built-in Protection Fuse protection per line, MOV surge, thermal shutdown, short circuit, snubber circuit Chokes 12 EMI Suppression Cooling Convection, 36” front clearance required Lightning Surge Protection High Voltage IEEE C62.41; (6000V & 3000A) Lightning Surge Protection Low Voltage ITU-T K.20 Loads 12 Manual Override Load by Load selectable Maximum Line Feeds 4 @ 20A (Maximum) breakers Minimum Load 5W@120V / 12W@277V Status Indicators Line Power, Fuse Status, Load Power, Over Temp, Microprocessor Status, Manual Override, Overload UL and CUL Listed Yes SCCR Rating 65KA General Specifications Dimensions, HWD REV 0 InFusion • Incandescent • LED • Fluorescent • HID • Cold cathode • Constant speed motors • Magnetic Low Voltage System Compatibility Load Types 1 2 3 4 5 6 7 8 9 10 11 12 7.63” 9.44” FRONT VIEWSIDE VIEW BOTTOM VIEW TOP VIEW 3.75” 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com UNIVERSAL DIMMING MODULE load controls UDM08-EM The InFusion Universal Dimming Module (UDM08-EM) provides load agnostic phase control as a component of Vantage’s centralized lighting control system. It can be mounted in a main or secondary power enclosure and supports control of up to 8 dimmable, forward and reverse phase type loads with up to four line feeds supporting up to 32 amps of total load per module. The module is designed to automatically detect load type, forward or reverse phase. In addition, with current sensing built in, the UDM supports enhanced conditional programming in Design Center for increased support of energy management scenarios. The UDM08-EM is designed for 120-277 VAC and 50/60Hz electrical specifications providing global electrical system compatibility. The module provides exceptional support of both low and high wattage LED and CFL lighting loads between 1-1200W@120VAC and 3-2770W@277VAC. The UDM08-EM module is compatible with new and old enclosures using new AC terminal boards. Each dimming channel can be programmable to match the dimming curve of the lighting load Module design eliminates the need for field wiring to the module Supports control of up to 8 forward or reverse phase loads 4 Line feeds supporting up to 32 amps per module, 10 amps maximum output for any of the 8 loads Offers load by load selectable load type (Forward/reverse phase control) Protection built in description operation product overview PROJECT LOCATION/TYPE PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com The UDM08-EM module ships in manual mode with load-by-load selectable phase control type (forward or reverse phase). Auto-load switching can be enabled per load through Design Center software. In addition, the module is designed with improved module locking mechanisms for simple in-field installation and service, allowing modules to be quickly replaced without affecting load connections to the system. Field Serviceability is enhanced with field service alerts sent via email to installers for their convenience. Programming, installing, and replacement have been made easier with these added features. • Offers load-by-load selectable load type (Forward/reverse phase control) • Auto load-type detection • Capable of custom load linerization profiles • Supports control of up to 8 universal loads • Firmware is field upgradeable • Plug-and-play design eliminates the need for field wiring to the module • Alarms to the controller can notify dealer or end user of problem by email • Includes built-in thermal, current, load type, and irregular load protection • Module is UL, CUL, and CE listed • Current sensing for energy management applications • 8000 dimming steps for smooth ramping and dimming • Displays the operating and fuse status with LED indicators at the top of the module • Self-powered design for uninterrupted lighting during servicing • Allows manual overrides to be programmed to any dim level • Programmable relay mode for added control flexibility The InFusion Universal Dimming Module is ideal for all lighting automation projects. Vantage’s InFusion systems are fully compliant with 2013 Title 24 requirements for both residential and non-residential buildings. Additionally, the UDM08-EM is UL, CUL, and CE listed. The InFusion Universal Dimming Module is a component of Vantage’s complete lighting control system. highlights features applications Universal Dimming Module 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 7.63” 9.44” FRONT VIEW SIDE VIEW BOTTOM VIEW TOP VIEW 3.75” 4 - 120/230/277V line feeds 50/60Hz20A maximum breaker size8 (2 per line feed)32A maximum10A maximum10A maximumIncandescent • Magnetic Transformers Electronic Ballast • Standard Ballast Inputs Number of OutputsTotal Load per ModuleTotal Load per Line FeedIndividual LoadLoad Types MODULE RATINGS CAUTIONCLEAR ALL LOADS OF SHORTS BEFORE INSTALLING MODULE SEE INSTRUCTION MANUAL BEFORE PARALLELING LOADS COMMERCIAL DIMMERS2K21UDM08-EM 120V/230V/277V UNIVERSAL DIMMING MODULEWITH ENERGY MANAGEMENT PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com specifications Universal Dimming Module 3 InFusion General Specifications Load Types System Compatibility Ordering Information Dimensions (HWD) UDM08-EM InFusion Universal Dimming Module 120-240V, 50/60Hz Up to 8 loads TUDM-KIT 12 Load Terminal Board Kit TUDM-L Left AC Terminal Board TUDM-R Right AC Terminal Board CATALOG NO. DESCRIPTION VOLTAGE MISC. 7.63” x 9.44” x 3.75” 194mm x 240mm x 95mm Model UDM08-EM Voltage 120V-277V ~ 60/50Hz Maximum Amperage per Module 32A (3840W@120V) 32A (7360W@230V) 32A (8864W@277V) Maximum Individual Load Amperage 10A (1200W @ 120V) 10A (2300W@230V) 10A(2770W@277V) Maximum Transformer Load 1000VA@120V 1916VA@230V 2300VA@277V Maximum Individual LED Load* 6A (720W@120V) 6A (1380W@230V) 6A (1662W@277V) Weight 5.7 lbs (2.6 kg) Ambient Operating Humidity 5 - 95% non-condensing Ambient Operating Temperature 32 - 104°F (0 - 40°C) Built-in Protection Fuse protection per line, MOV surge, thermal shutdown, short circuit Cooling Convection, 36” front clearance required Lightning Surge Protection High-voltage IEEE C62.41; (6000V & 3000A) Lightning Surge Protection Low-voltage ITU-T K.20 Loads 8 Manual Override Load-by-load selectable Maximum Line Feeds 4 @ 20A (Maximum) breakers Minimum Load 2W@120V 4W@240V 5W@ 277V Status Indicators Line Power, Fuse Status, Load Power, Over Temp, Microprocessor Status, Manual Override, Overload UL, CUL, and CE Listed Yes SCCR Rating 5KA • Incandescent • LED* • Fluorescent • Halogen • Constant Speed Motors • Standard Ballast • Magnetic Low-voltage • Magnetic Transformers • Electronic Ballast PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com terminal boards for the Universal Dimming Module Universal Dimming Module 4 Vantage is leading the way in LED lighting control through innovations of new hardware and software products; however, industry standards are still undefined for dimming LED lamps and fixtures. Dimming performance of LED lighting cannot be guaranteed, even when applying the correct dimming technology specified by the LED manufacturer. While Vantage may be consulted when performance issues are present, Vantage will not be liable for on-site performance issues. Vantage recommends the following to assist installers and lighting specifiers: • Check Vantage’s online library of LED product test reports prior to installing LED products to be dimmed by Vantage dimmers • Utilize our on-demand product testing of untested LED products - Please contact Vantage for details regarding this service • Selecting a tested product greatly increases the likelihood of successful dimming; however, LED product tests are performed under laboratory conditions with a set number of samples and a quality power source • There are many factors that may contribute to unsatisfactory results within a specific installation, including, but not limited to: - line noise originating from electrical equipment within the premises - line noise from the source (particularly with local generators or inverters) - interference between dimmed LED products - wiring conditions (i.e. shared neutrals, loose neutrals, incorrectly bonded neutral, or grounding issues) - LED product variances, including: • unintended batch-related variances • product revisions LED Dimming PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com Prevents arcing and extends module life with zero-cross switching • technology Includes individual switches for direct control of each of the eight relays• Features a plug-and-play design• Plugs into terminal boards located within the enclosure• Switches high-voltage loads• Offers load by load selectable manual override control• Displays the operating status with LED indicators including:• Microprocessor status ○ Line feed power ○ Manual override ○ LATCHING RELAY Vantage’s Relay Module provides relay functions on eight individual load channels. Every load is controlled by a high voltage relay and is powered by two loads per 20 Amp circuit breaker. Two Relay Modules are available. One module features control for 120V and the other controls 210-277V. Each module is designed to easily plug into a Vantage Enclosure. All AC wiring is terminated into screw terminal connectors within the enclosure. This feature allows the Relay Module to be installed after the building has been finished, eliminating the potential for damage during construction. The relay also features zero-cross switching technology to minimize wear on the electrical contacts and increase the life of the module. Product Highlights Load Controls PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com Latching Relay Specifications 7.62” x 6.9” x 1.875” 194mm x 175mm x 47.6mm Models MDR8RW101 & MDR8RW201 Weight 1lb. 11oz. (765g) Voltage MDR8RW101 is 120V ~ 60/50Hz; MDR8RW201 is 210-277V ~ 60/50Hz Ambient Operating Humidity 5 - 95% non-condensing Ambient Operating Temperature 32 - 104°F (0 - 40°C) Arc Suppression Zero Cross Built-in arc suppression Built-in Protection MOV surge suppression Cooling None required Lightning Surge Protection High Voltage IEEE C62.41 (6000V & 3000A) Lightning Surge Protection Low Voltage ITU-T K.20 Loads 8 Manual Override Load by Load selectable Maximum Amperage per Module 80A (9600W @ 120V); *(22160W @ 277V); *(19200W @ 240V) Maximum Individual Load Amperage 20A (2400W @ 120V); *(5540W @ 277V); *(4800W @ 240V) Maximum Line Feeds 4 @ 20A (Maximum) breakers Status Indicators Line Power, Load Power, Microprocessor Status, Manual Control UL and CUL Listed Yes General Specifications Dimensions, HWD REV 0 InFusion QLink Wire Requirement Copper wire, minimum of 80°C (176°F) insulation • Incandescent • Fluorescent • Constant speed motors • HID • Cold cathode System Compatibility Wiring Specifications Load Types FRONT VIEW SIDE VIEWBACK VIEW 6.9"1.87" 7.62" 12345678 MDR8RW201VANTAGE 1 OFFON 2 OFFON 3 OFFON 4 OFFON 5 ON OFF ON OFF ON OFF ON OFF 6 7 8 4 - 2 2 0 V - 2 7 7 V l i n e f e e d s 5 0 / 6 0 H z 20 A m a x i m u m b r e a k e r s i z e 8 ( 2 p e r l i n e f e e d ) 20 A m a x i m u m 20 A i n c a n d e s c e n t l o a d s ( U p t o 2 7 7 V ) 20 A b a l l a s t s ( U p t o 2 7 7 V ) 17 F L A m o t o r l o a d s ( U p t o 2 4 0 V ) 14 F L A m o t o r l o a d s ( U p t o 2 7 7 V ) In p u t s Nu m b e r o f O u t p u t s To ta l L o a d p e r M o d u l e To ta l L o a d p e r L i n e F e e d In d i v i d u a l L o a d MD R 8 R W 2 0 1 22 0 V - 2 7 7 V R E L AY M O D U L E MO D U L E R A T I N G S CA U T I O N CL E A R A L L LO A D S OF S H O R T S BE F O R E IN S T A L L I N G MO D U L E 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com DIN Low Voltage Relay Station The Vantage DIN Low Voltage Relay Station is a powerful control point for systems or devices that operate through low voltage relay control. A DIN LVRS includes eight SPDT relays to control devices such as draperies, pumps, garage doors, lifts, screens, pool covers, sprinklers, showers, baths, security systems and more. Each relay corresponds to an individual button on the front of the unit, which allows the connected device to be manually switched. The individual relays “latch” to retain the last state in the event of a power interrupt. Low Voltage Relay Stations, available in WireLink or RadioLink, easily install on standard 35mm DIN rails. The stations communicate with the controller either through a WireLink two-wire bus or wireless RadioLink. Each station can quickly become part of Vantage’s powerful scene orchestration capabilities with user friendly programming software. product highlights • Provides a single integration point for up to eight relay channels • Allows effortless control of devices such as draperies, pumps, garage doors, lifts, screens, pool covers, sprinklers, showers, security systems, and much more • Clips easily on standard 35mm DIN rails • Accepts programming using Vantage’s InFusion Design Center or QLink software • Communicates with the controller via WireLink or RadioLink • Features eight buttons to manually control each relay Vantage® or Vantage Controls®, RadioLink®, Design Center™, InFusion™, QLink™, and WireLink™ are registered trademarks of Vantage Controls, Inc. PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com WireLink DIN Low Voltage Relay Station RadioLink DIN Low Voltage Relay Station DIN-LVRSRL SERIAL NUMBERwith RadioLink OPEN ENERGY MANAGEMENT EQUIPMENT51XT DIN-LVRS SERIAL NUMBERSTATION BUS CLASS 2 OPEN ENERGY MANAGEMENT EQUIPMENT51XT NON-POLARIZED12-36VDC12-28VAC200mA IN 4 5 6 7 832 SE T CO M RE S E T SE T CO M RE S E T SE T CO M RE S E T SE T CO M RE S E T SE T CO M RE S E T SE T CO M RE S E T SE T CO M RE S E T SE T CO M RE S E T 1 MAX RATINGS 1AMP48VAC30VDC STATUSDIN LOW VOLTAGE RELAY STATION SET 1 7 823456 86mm DIN Low Voltage Relay Station SIDE VIEW FRONT VIEW TOP VIEW specifications 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com REV 1.1 Dimensions, HWD Wiring Specifications General Specifications Models STOLEW801 (WireLink) / STOLER821 (RadioLink) Weight 201 g (8.04 oz) Mounting 35mm DIN Rail (EN 50 022: 1977) Ambient Operating Humidity 5-95% non-condensing Ambient Operating Temperature 0°-40° C (32°-104° F) Lightning Surge Protection Low Voltage ITU-T K.20 Number of Relay Actuators 8 Number of SPDT Relays 8 Maximum Current at Relay 1 A Maximum Voltage at Relay 48 VAC / 30 VDC Software Requirements RadioLink InFusion Design Center or QLink version 4.0 or higher Software Requirements WireLink InFusion Design Center or QLink version 3.5 or higher Station Equivalent InFusion 0.5W on IC-24 / 0.5W on IC-36 Station Equivalent QLink 1 Station on QLink Main Controller 86mm x 157mm x 58mm 3.4” x 6.18” x 2.28” Station Bus Wiring Minimum 2 conductor, 16 AWG stranded, non-shielded twisted pair, 30 pF/foot max, UL rated CL2 Station Bus Topology Any combination of daisy chain or star or branch or home run RadioLink RF Specifications Station Equivalent 1 RF station FCC ID# PII-VSUB075-1 IC 3505A-VSUB0751 Frequency Range 902–928 MHz ISM band RF Technology Frequency hopping spread spectrum Number of Channels 25 58mm 157mm PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com Provides a single integration point for up to ten contact inputs• Allows seamless integration with most passive infrared motion • detectors, door contacts, light sensors, smoke and carbon monoxide detectors, and more Clips easily on standard 35mm DIN rails• Accepts programming using Vantage’s InFusion Design Center or QLink • software Communicates with the controller via WireLink or RadioLink• Two connections for a Vantage external IR Receiver and LightPoint • Sensor ContaCt Input StatIon - DIn the DIn Contact Input Station provides a single integration point for a large variety of sensor inputs and external switches from third-party systems. Each station features ten contact input channels for monitoring the open and close states from a variety of external devices. these devices include magnetic door contact switches, momentary switches, motion detectors, smoke and carbon monoxide detectors, driveway probes, and more. Input 9 can also be used to receive input from Vantage’s external IR receiver. Input 10 can be used for the Vantage Lighpoint sensor. Contact Input Stations, available in WireLink or RadioLink versions, easily install on standard 35mm DIn rails. the stations communicate with the controller either through a WireLink two-wire bus or wireless RadioLink. Each station can quickly become part of Vantage’s powerful scene orchestration capabilities with user friendly programming software. product Highlights Integration Modules PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com Contact Input Station - DIn Specifications 3.4” x 6.18” x 2.28” 86 mm x 157 mm x 58 mm Models CIS10-DIN (WireLink) / DIN-STIDER121 (RadioLink) Weight 201 g (8.04 oz) Mounting 35 mm DIN Rail (EN 50 022: 1977) Number of Contact Inputs 10 Ambient Operating Humidity 5-95% non-condensing Ambient Operating Temperature 0°-40° C (32°-104° F) Cooling Convection Maximum Current from +12 V 50 mA combined Software Requirements InFusion Design Center or QLink version 4.0 or higher Station Equivalent InFusion InFusion counts as 0.5W on IC-24 / 0.7W on IC-36 Station Equivalent QLink 1 Station on QLink Main Controller General Specifications Dimensions, HWD InFusion QLink Station Bus Wiring Minimum 2 conductor, 16 AWG stranded, non-shielded twisted pair, 30 pF/foot max, UL rated CL2 Station Bus Topology Any combination of daisy chain or star or branch or home run Station Equivalent 1 RF station FCC ID# PII-VSUB075-1 IC 3505A-VSUB0751 Frequency Range 902–928 MHz ISM band RF Technology Frequency hopping spread spectrum Number of Channels 25 System Compatibility Wiring Specifications RadioLink RF Specifications SIDE VIEW FRONT VIEW TOP VIEW 2.28” IN GN D 6 IN GN D 7 IN GN D 8 IN GN D 9 IN GN D 10 +12VDC OUTPUTS 50mA Max TotalINGN D 5 IN GN D 4 IN GN D 3 IN GN D 2 IN GN D 1 IN GND SENSOR +12V IR SE N S O R 3.4” 6.18” STATUSCONTACT INPUT STATION 10 - DIN CONTACTSTATE PROGRAMSTATE 1 2 3 4 5 6 7 8 9 10 CIS10-DIN STATION BUS CLASS 2 OPEN ENERGY MANAGEMENT EQUIPMENT51XT SERIAL NUMBER 1061 South 800 East orem, utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com • Controls up to eight separate sets of LED, CFL, or CCFL lighting loads • Offers control of either 0-10 or PWM type loads • Allows for the addition of dry contact inputs to the automation network including motion sensors, light sensor, IR input, pressure sensors, magnetic switches, and more • Manual control and LED status for all eight outputs on front • Installs on DIN rail • Powered by 13.8 to 36VDC • Firmware upgradable in the field 0-10 PWM LOW VOLTAGE OUTPUT STATION-DIN The 0-10 PWM Low Voltage Output Station-DIN is used for the control and automation of LED, CLF and CCFL lighting loads requiring either 0-10 or PWM for dimming control. Each LVOS DIN features eight 0-10 outputs with four that can be turned into PWM outputs. The LVOS DIN is firmware upgradable in the field through its station bus, has four dry contact inputs with two addtional override inputs and is powered by 13.8 to 36VDC. The dry contact inputs can be used with motion sensors, light sensors, pressure sensors, IR input, magnetic switches, and more. Product Highlights Load Controls PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com Model LVOS-0-10-PWM-DIN Weight 2lbs 8oz (1.13kg) Mounting DIN Rail Ambient Operating Humidity 5-95% non-condensing Ambient Operating Temperature 0-35°C (32-95°F) Auxiliary Inputs 4 Dry Contacts Override Inputs 2 (On and Off Contacts) Input power 13.8 - 36VDC Power Consumption 15W LED Indicators Microprocessor Status, Configuration, Load Number of Low Voltage Loads 8 Low Voltage Loads 100mA Sink/Source (0-10) 100mA Source (PWM) Station Equivalent InFusion 0.35W on IC-24 / 0.55W on IC-36 Station Bus Connections 24V / 36V Station Bus CE Listed Yes 0-10 PWM Low Voltage Output Station-DIN Specifications 3.4” x 6.18” x 2.375” 86mm x 157mm x 60mm General Specifications Dimensions, HWD InFusion Station Bus Wiring Minimum 2 conductor, 16 AWG stranded, non-shielded twisted pair, 30 pF/foot max, UL rated CL2 Station Bus Topology Any combination of daisy chain or star or branch Station Bus should be separated a minimum of 18” from other parallel communication and/or high voltage runs System Compatibility Wiring Specifications OU T GN D 1 96mm FRONT VIEW BOTTOM VIEW TOP VIEW 157mm 1 7 823456 STATUSLOW VOLTAGE OUTPUT STATION-0-10-PWM-DIN RED = 0-10 GREEN = PWM LVOS-0-10-PWM-DIN0-10: 10VDC@100mA MAX PWM: 12VDC@100mA MAX INPUT 13.8-36VDC SET STATION BUS CLASS 2 LVOS-0-10- PWM-DIN SERIAL NUMBER OU T GN D OU T GN D 2 OU T GN D 3 OU T GN D 4 1 2 3 IR 4 SENS OU T OU T OU T GN D OF F GN D ON OU T STATION BUS CLASS 2 OU T GN D 5 OU T GN D 6 OU T GN D 7 OU T GN D 8 SIDE VIEW 60mm 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com Incorporates up to 60 RF stations per Enabler• Communicates seamlessly with the Vantage hard-wired system• Features a plug-and-play design• Uses digital spread spectrum technology• Hops between 25 channels to avoid interference • Operates at 900 MHz for clear FM transmissions• Features a 100 foot transmission radius per enabler (over 4 million cubic • feet) Runs on the same software used for the wired stations• The Enabler easily connects to the existing RS-232 and power connections • on the main terminal board RADIOLINK ENABLER The Vantage RadioLink Enabler is a wireless transceiver that adds radio frequency (RF) communication ability to a standard wired Vantage system. With RadioLink, small transceivers are built into the Vantage products offering automation for lighting, audio/video, draperies, blinds, security, heating, cooling and more. By connecting a RadioLink Enabler to an existing Vantage main controller, RF enabled keypads and other station devices are able to communicate with the system. Each RadioLink Enabler supports up to 60 RadioLink stations with a transmission radius up to 100 feet. This is in addition to the usual WireLink stations, that can be wired to a main controller’s station bus. Product Highlights Integration Modules PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com RadioLink Enabler Specifications 7.8” x 2.4” x .9” 198mm x 61mm x 23mm Model RFE1000 Weight 3 oz (85g) Ambient Operating Humidity 5–95% non-condensing Ambient Operating Temperature 32-158°F (0-70°C) Controller Firmware InFusion Firmware or QLink Firmware version 6.20 or higher Current Required While Receiving 70mA Current Required While Transmitting 180mA LED Indicators • Handshake Out (RTS) • Data In (RX) • Data Out (TX) • GND • +12V Power Supply 12 VDC Software Requirements InFusion or QLink version 3.2 or higher Station Count 1 station Station Support Supports up to 60 RadioLink (RF) stations per Enabler InFusion QLink Installed Distance From Controller 30 ft. maximum, 6 in. minimum from any metal enclosure RS-232 Connection on Master Terminal Board 5 conductor, 22 gauge or larger FCC ID# PII-VSUB075-1 or PII-VSUB235 IC ID# 3505A-VSUB0751 or 3505A-VSUB235 Frequency Range 902–928 MHz ISM band Number of Channels 25 RF Technology Frequency hopping spread spectrum Transmit Power 140mW General Specifications System Compatibility Wiring Specifications RadioLink Specifications Dimensions, HWD REV 0 2.4" Th i s de v i c e co m p l i e s wi t h P ar t 15 of th e FC C Ru le s . O p e r a t i o n i s s u b j e c t t o t h e f o l l o w i n g t w o co n d i t i o n s : ( 1 ) T h i s d e v i c e m a y n o t c a u s e h a r m f u l in t e r f e r e n c e , a n d ( 2 ) t h i s d e v i c e m u s t a c c e p t a n y in t e r f e r e n c e r e c e i v e d , i n c l u d i n g i n t e r f e r e n c e t h a t ma y c a u s e u n d e s i r e d o p e r a t i o n . RAD I O L I N K EN A B L E R RF E 1 0 0 0 Th i s d e v i c e c o n t a i n s o n e o f t h e f o l l o w i n g tr a n s m i t t e r m o d u l e s : FC C I D : P I I - V S U B 0 7 5 - 1 IC : 3 5 0 5 A -V SU B 0 7 5 1 FC C I D : P I I - V S U B 2 3 5 IC : 3 5 0 5 A - V S U B 2 3 5 OR SIDE VIEW 3.8"4.0" 0.9"BOTTOM VIEW +1 2 V TX Connect ToMatching PinsOn MasterTerminal Board RX GN D TXRXRT SBOTTOM VIEW Controller Interface 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com Load Controls Communicates with the Vantage System through Radio Link • technology Enables two separate devices to be independently controlled by • commands received from keypads, timed events, sensors, and more Features default programming for local control when not connected to • the Vantage System Provides 300 Watts of dimming control per load• Two models that configures plug with ground up or ground down• Allows the device to be turned on from its own switch• Includes LED indicators for easy component diagnostic• ACCENTPOINT II DIMMER AccentPoint II Dimmer allows homeowners to independently control two plug-in devices, such as floor or table lamps, through the Vantage System. Connected via radio frequency, these devices can be controlled by commands received from keypads, timed events, remote controls, sensors, and much more. AccentPoint offers up to 300 watts of dimming per connected device. These devices include incandescent or low voltage magnetic lamp fixtures. It also features a button with default programming to allow for local control of the appliance when it is not connected to the Vantage System. Product Highlights PROJECT: 200 S. Aspen DATE: Jan 25, 2016 TYPE: CONTROLS 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 4341 cr 113, carbondale, co 81623 (970) 948-2637 aaron@alpenglowinc.com 1061 South 800 East Orem, Utah 84097 800.555.9891 801.224.0355 fax www.vantagecontrols.com ACCENTPOINT II DIMMER Specifications 4.125” x 3.125” x 1.25” 107.95mm x 79.37mm x 31.75mm Models APDIM/APDIM-GU (Ground up) Weight 5.5 oz (156g) Ambient Operating Humidity 5 - 95% non-condensing Ambient Operating Temperature 32 - 95°F (0 - 35°C) LED Indicator Status Lightning Surge Protection High Voltage IEEE C62.41 (6000V & 3000A) Load Types Incandescent or low voltage magnetic fixtures only Maximum Current per Load 2.5A Each Load Maximum Watts Per Load 300W@120V Mounting Plugs into standard 120VAC Outlet Station Equivalent 1 RadioLink Station Voltage 120V, 60Hz UL and CUL Listed Yes FCC Yes General Specifications Dimensions, HWD REV 0 InFusion QLink System Compatibility TOP VIEW FRONT VIEW BOTTOM VIEW BACK VIEW SIDE VIEW 4.125" 1.25" ACCENTPOINT DIMMER II - APDIM INPUT: 120VAC, 60Hz OUTPUT: 2.5A max per load FCC ID: PII-AP2RL IC: 3505A-AP2RL LISTED51XT 3.125"