Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.1039 E Cooper Ave.0190.2018 (5).ARBK
Job Name: System Reference:Date: GENERAL FEATURES •Variable speed INVERTER-driven compressor • Energy Star® certified (non-ducted) • M-NET connection through outdoor unit • Quiet outdoor unit operation as low as 50 dB(A) • New Intelligent Power Module (IPM) for reduced power loss • Selectable thermal lockout/restart function • Optional base pan heater • High pressure switch for additional protection • Thermal differential of +/-1° F from setpoint SUBMITTAL DATA: MXZ-2C20NA2 1.5-TON MULTI-ZONE INVERTER HEAT-PUMP SYSTEM Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. M-SERIES Model number Outdoor unit MXZ-2C20NA2 Indoor unit type Non- Ducted Mix Ducted Cooling*1 Maximum Capacity Btu/h 20,000 Rated Capacity Btu/h 18,000 19,000 20,000 Minimum Capacity Btu/h 5,700 Maximum Power Input W 2,245 Rated Power Input W 1,417 1,709 2,000 Power Factor % 98.7 99.3 99.9 Heating at 47° F*2 Maximum Capacity Btu/h 25,000 Rated Capacity Btu/h 22,000 Minimum Capacity Btu/h 7,400 Maximum Power Input W 2,455 Rated Power Input W 1,641 1,706 1,771 Power Factor % 96.2 97.9 99.6 Heating at 17° F *3 Maximum Capacity Btu/h 15,500 15,000 14,500 Rated Capacity Btu/h 12,500 13,000 13,500 Maximum Power Input W 1,750 1,780 1,810 Rated Power Input W 1,300 1,325 1,350 Heating at 5° F *4 Maximum Capacity Btu/h 11,100 11,000 10,900 Maximum Power Input W 1,600 1,625 1,650 Efficiency SEER 20.00 18.00 16.00 EER *1 12.70 11.35 10.00 HSPF (IV)10.00 9.65 9.30 COP at 47° F *2 3.93 3.78 3.64 COP at 17° F *3 2.82 2.87 2.93 ENERGY STAR® Certified YES NO NO Electrical Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208V / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 12-24 Voltage: Indoor - Remote controller V DC 24 Recommended Fuse/Breaker Size A 20 Recommended Wire Size (Indoor - Outdoor) AWG AWG14 Outdoor unit MCA A 17.2 SPECIFICATIONS: MXZ-2C20NA2 Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. Model number Outdoor unit MXZ-2C20NA2 Indoor unit type Non- Ducted Mix Ducted Fan Motor Full Load Amperage A 1.77 Fan Motor Output W 64 Airflow Rate CFM 1,342 / 1,458 Refrigerant Control Liner Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling*1 dB(A)50 Sound Pressure Level, Heating*2 dB(A)54 Compressor Type Twin Rotary type Compressor Model SNB140FQUH2T Compressor Motor Output kW 1.5 Compressor Rated Load Amps A 10.7 Compressor Locked Rotor Amps A 15.5 Compressor Oil Type // Charge oz.NEO22 / 20.3 External Finish Color Munsell 3.0Y 7.8/1.1 Base Pan Heater Optional Unit Dimensions W: In. [mm]33-1/16 [840] D: In. [mm]13 [330] H: In. [mm]27-15/16 [710] Package Dimensions W: In. [mm]40 [1,010] D: In. [mm]18-1/2 [470] H: In. [mm]33-1/2 [850] Unit Weight Lbs.[kg]126 [57] Package Weight Lbs.[kg]147 [67] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum) °F 14 to 115 Heating Intake Air Temp (Maximum / Minimum) °F 5 to 75 Thermal Lock-out / Re-start Temperatures °F Cooling: 10.4 / 14 Heating: 1.5 / 5 Refrigerant Type R410A Charge Lbs., Oz.3, 15 Indoor unit connection Maximum Number of Connected IDU 2 Minimum Number of Connected IDU 2 Maximum connected capacity Btu/h 24,000 SPECIFICATIONS: MXZ-2C20NA2 Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. Model number Outdoor unit MXZ-2C20NA2 Indoor unit type Non- Ducted Mix Ducted Minimum connected capacity Btu/h 12,000 Piping Gas Pipe Size O.D. (Flared)In.[mm]3/8 [9.52] Liquid Pipe Size O.D. (Flared)In.[mm]1/4 [6.35] Total Piping Length Ft. [m]164 [50] Maximum Height Difference, ODU above IDU Ft. [m]33 [10] Maximum Height Difference, ODU below IDU Ft. [m]49 [15] Farthest Piping Length from ODU to IDU Ft. [m]82 [25] Maximum Number of Bends 50 AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) *1 Cooling (Indoor // Outdoor)°F 80°F DB, 67°F WB // 95°F DB, 75°F WB *2 Heating at 47°F (Indoor // Outdoor) °F 70°F DB, 60°F WB // 47°F DB, 43°F WB *3 Heating at 17°F (Indoor // Outdoor) °F 70°F DB, 60°F WB // 17°F DB, 15°F WB Conditions *4 Heating at 5°F (Indoor // Outdoor)°F 70°F DB, 60°F WB // -4°F DB, -5°F WB For reference to connected capacity charts, please refer MXZ-2C20NA2-U1 Operational Performance. Notes: SPECIFICATIONS: MXZ-2C20NA2 Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. Joint Pipe Unit φ9.52 → Pipeφ15.88 □ PAC-SG76RJ-E Unit φ6.35 → Pipeφ9.52 □ PAC-493PI Unit φ9.52 → Pipeφ12.7 □ MAC-A454JP-E Unit φ12.7 → Pipeφ9.52 □ MAC-A455JP-E Unit φ12.7 → Pipeφ15.88 □ MAC-A456JP-E Air Discharge Guide □ MAC-856SG Base Pan Heater □ PAC-646BH-E Control Cable □ CW162S 3-pole Disconnect □ TAZ-MS303 M-NET Adapter □ PAC-IF01MNT-E Wall Mounting Bracket (Powder-coated Steel)□ QSWB2000M-1 Wall Mounting Bracket (316 Series Stainless Steel)□ QSWBSS Outdoor Unit Mounting Pad 24" x 42" x 3"□ ULTRILITE2 MiniSplit Mounting Stand-Dual Fan models - 12"□ QSMS1202M MiniSplit Mounting Stand-Dual Fan models - 18"□ QSMS1802M MiniSplit Mounting Stand-Dual Fan models - 24"□ QSMS2402M Diamondback Linesets*1 1/4 x 1/2 x 15' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-15 1/4 x 1/2 x 30' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-30 1/4 x 1/2 x 50' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-50 1/4 x 1/2 x 65' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-65 1/4 x 1/2 x 100' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-100 3/8 x 5/8 x 10' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-10 3/8 x 5/8 x 15' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-15 3/8 x 5/8 x 30' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-30 3/8 x 5/8 x 50' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-50 3/8 x 5/8 x 65' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-65 3/8 x 5/8 x 100' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-100 *1 Linesets are indoor unit specific and will be listed in the IDU information - the Joint Pipe adaptors are used in this application ACCESSORIES: MXZ-2C20NA2 Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc. 17 Connectingwire hole 1- 2 5 / 3 2 ” 18 - 1 / 8 29/32” 3- 5 / 1 6 ” 5- 5 / 1 6 ” 11-25/32” 14 - 3 / 1 6 ” 27 - 1 5 / 1 6 ” 9- 7 / 1 6 ” 7-7/8” 1-3/16”33-1/16” Unit A GAS GAS LIQ LIQ LIQ 1/4”(ø6.35)FLARE GAS 3/8”(ø9.52)FLARE Unit B Connectingwire hole 1-1/32” 13” 2-19/32” 1/2” (B o l t P i t c h ) (Foundation Bolt M8) 4-(13/32”×13/16”) Oval Hole 3-ø(1-5/16”) Drain hole AirInlet Air Inlet Air Outlet 14 - 3 / 1 6 ” 15 / 3 2 ” 2 3 / 3 2 ” 21 / 3 2 ” 1- 1 1 / 3 2 ” 2-9/16”12-3/8”8-5/32” 6-21/32”6-23/32”19-11/16” 11 / 1 6 ” 11 / 1 6 ” 15 - 1 9 / 3 2 ” Handle Unit: inch (mm) OUTLINES AND DIMENSIONS5 Lock nut Connector Grounding terminal Conduit cover OBH702F FORM# MXZ-2C20NA2 - 201706 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: MXZ-2C20NA2 Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc.