HomeMy WebLinkAboutFile Documents.533 W Hallam St.0285.2018 (136).ARBKWELS #1 Markup 533 W Hallam Page: [1] 2018-0126-IR-1 (Irrigation Plan) Author: rickma Date: 12/14/2018 8:49:45 AM File Name: Irrigation Plan. 533 W Hallam.pdf Please provide an emitter schedule which indicates: plant type (trees, shrubs, perennials, seeded areas) and size by hydrozone, emitters per plant, g.p.m. per emitter, and total g.p.m. per plant. [1] 2018-0126-IR-1 (Irrigation Plan) (2) Page: [1] 2018-0126-IR-1 (Irrigation Plan) Author: rickma Date: 12/13/2018 3:08:12 PM File Name: Irrigation Plan. 533 W Hallam.pdf Please include the language of WELS Section 4.3.2 (m) regarding irrigation work under existing trees. Page: 4 Author: rickma Date: 12/13/2018 3:42:13 PM File Name: Landscape Plans. 533 W HALLAM.pdf Revise to comply with WELS Section 4.2 (4") 4 (1) 6 Rain Bird XCZ-LF-100-PRF 1"Area for Drip 7 Rain Bird XCZ-LF-100-PRF 1"Area for Drip 8 Rain Bird XCZ-LF-100-PRF 1"Area for Drip 9 Rain Bird XCZ-LF-100-PRF 1"Area for Drip 10 Rain Bird XCZ-LF-100-PRF 1"Area for Drip 11 Rain Bird XCZ-LF-100-PRF 1"Area for Drip 12 Rain Bird XCZ-LF-100-PRF 1"Area for Drip Common Wire Please provide an emitter schedule which indicates: plant type (trees, shrubs, perennials, seeded areas) and size by hydrozone, emitters per plant, g.p.m. per emitter, and total g.p.m. per plant. 14.Project is designed to meet City of Aspen Water Efficient Landsc Standards adopted by Ordinance #17 series 2018. These standar require a post installation inspection by the Certified Irrigation D (CID) and an irrigation audit by a Certified Landscape Irrigation A (CLIA) as part of the approval letter process. Changes and varian the design must be approved by the Certified Irrigation Designe prior to installation, unapproved changes may warrant failure of inspection, corrections will be at installer's expense. Please include the language of WELS Section4.3.2 (m) regarding irrigation work under existing trees. 1. All Discrepancies Should Be Reported To The Landscape Architect.2. Locate All Utilities Before Digging.3. All Areas Shown Are Approximate Only. Verification Of Areas To Site Between The Contractor And Landscape Architect.4. Grades Are To Be Checked And Approved By The Lanscape Archit Material. 5. Location Of Plant Material Is To Be Approved By The Landscape A 6. Quality Of Plant Material Is To Be Approved By The Landscape Ar 7. All Trees, Shrubs, And Groundcover Areas To Be Covered With A Of 3".8. All Deciduous Trees Are To Be Staked And Guyed As Specified. 9. Provide "pre-mixed" Planting Mixture For Use Around The Balls An Consisting Of 4 Parts Topsoil To 1 Part Peat Moss .10. Planting Beds Are To Contain "pre-mixed" Plant Mixture To A Min 11. All Planting Beds Are To Be Contained By 4" Metal Edging.12. Slopes Of 2 To 1 Or Greater Are To Be Covered With An Erosion Green S\c150 Or Equal)13. All Newly Planted Areas To Be Irrigated With An Automatic Irriga Revise to comply with WELS Section 4.2 (4") Page: 5 Author: rickma Date: 12/14/2018 12:35:21 PM File Name: Landscape Plans. 533 W HALLAM.pdf Please revise this legend to correspond with the designations on the water budget worksheet, e.x., H-Zone A, H-Zone B, etc. 5 (11) Page: 5 Author: rickma Date: 12/14/2018 12:27:56 PM File Name: Landscape Plans. 533 W HALLAM.pdf There isn't a "H Zone A-Drip Trees" or valve(s) depicted on the irrigation plans for trees. Please revise accordingly. Page: 5 Author: rickma Date: 12/14/2018 12:30:49 PM File Name: Landscape Plans. 533 W HALLAM.pdf Are the 4" spaces between concrete pavers included in this VH hydrozone area? Page: 5 Author: rickma Date: 12/14/2018 9:05:26 AM File Name: Landscape Plans. 533 W HALLAM.pdf Where are these shrubs on the plans? 9. All Planting Beds Are To Be Contained By 4" Metal Edging.10. Irrigate All Disturbed Areas With An Automatic Irrigation System.11. Layout All Planting Beds And Edge Prior To Plant Installation.12. All Plerennials Are To Be Layed Out With Uniform Spacing. Layout To Be Approved By Contractor Prior To Installation.13. Contractor To Provide & Install Drainage And Irrigation/ Lighting Sleeves As Needed For All Planting Areas. eed free straw. “I have complied with the criteria of the Water Efficient LandscapingStandards and applied them for the efficient use of water in the landscape design plan”. Ben Morgan RLA Water Usagage Legend VH= High - Drip M = Medium - Drip L = Low - Drip Hydrozones VH = Right of Way - Spray Please revise this legendto correspond with thedesignations on the waterbudget worksheet, e.x., H-Zone A, H-Zone B, etc. 7914 There isn't a "H Zone A-Drip Trees" or valve(s) depicted on the irrigation plans for trees. Please revise accordingly. Native Grass MIxCommon Name Scie CrestedWheat, Ephraim Agr Sheep Fescue Fes Perennial Ryegrass Loli Canada Blue, Talon PoaChewings Fescue Fes Revegetate disturbed area A Plantago-based tackifie should be applied on all s acre to prevent wind fromrevegetated areas. Seed Mix Are the 4" spaces between concrete paversincluded in this VH hydrozone area? Sod E F M ie K N P W P Where are these shrubs on the plans? Page: 5 Author: rickma Date: 12/13/2018 3:31:34 PM File Name: Landscape Plans. 533 W HALLAM.pdf Mugo pine is not depicted on the planting plan Page: 5 Author: rickma Date: 12/13/2018 4:39:18 PM File Name: Landscape Plans. 533 W HALLAM.pdf The irrigation method on irrigation plans appears to be drip, not overhead. Page: 5 Author: rickma Date: 12/14/2018 12:30:42 PM File Name: Landscape Plans. 533 W HALLAM.pdf Is this seed mixture proposed for this project? If not, please remove. Page: 5 Author: rickma Date: 12/14/2018 12:25:30 PM File Name: Landscape Plans. 533 W HALLAM.pdf A number of plants in the legend are not depicted on the planting plans. Revise legend and/or plan accordingly Sod C SW Mugo pine is not depicted on the planting plan The irrigation method on irrigation plans appears to be drip, not overhead. 7 By Contr 13. Contract Planting Native Grass MIxCommon Name Scientific Name % of Mix CrestedWheat, Ephraim Agropyron cristatum 30 Sheep Fescue Festuca ovina 20Perennial Ryegrass Lolium perenne 25Canada Blue, Talon Poa compressa 15Chewings Fescue Festuca rubra commutata 10 Revegetate disturbed areas by hand seeding with a certified weed free straw. A Plantago-based tackifier, or similar approved product, should be applied on all straw at the rate of 150 lbs per acre to prevent wind from blowing straw off the revegetated areas. Seed Mix Water Usa Hydro Is this seed mixtureproposed for thisproject? If not, please remove. 79 1 2 Sod SodNative Grass Mix Assorted Groundcov Groundcovers ie. Mugo Pine Cranesbill Blue Purple & White Delphin Purple Maiden Grass Blue Siberian Iris Sweet Woodruff Rocky Mountain Colum Woolly Thyme Dwarf Shasta Daisey Hosta 'White Rimmed' Bowles PeriwinkleBlue Spike SpeedwellDwarf Fall Aster Black-Eyed Susan Bleeding Heart Blue LupineDwarf Gold 'Daylily'Bishop's WeedBW BH BP CB FA SD H BSS I BESPMG BLD C DL SW WT Maroon HollyhockMH Sod White PeoniesWP Creeping SpeedwellCS A number of plants inthe legend are notdepicted on theplanting plans. Reviselegend and/or planaccordingly Page: 5 Author: rickma Date: 12/13/2018 2:23:18 PM File Name: Landscape Plans. 533 W HALLAM.pdf Include the language of WELS Section 4.2- Mulch Criteria Page: 5 Author: rickma Date: 12/14/2018 9:11:17 AM File Name: Landscape Plans. 533 W HALLAM.pdf Cool season turf is VH Page: 5 Author: rickma Date: 12/14/2018 12:31:12 PM File Name: Landscape Plans. 533 W HALLAM.pdf The surface area of hot tub should be in calculations, if one is proposed 913 791 2 5. Locatio 6. Quality7. All Plan Mulch N 8. Planting 9. All Plan 10. Irrigat 11. Layou 12. All Ple By Co 13. Contr Plantin Hydr Include the language of WELS Section 4.2- Mulch Criteria Cool season turf is VH A sho ac rev The surface area of hot tub should be in calculations, if one is proposed