HomeMy WebLinkAboutFile Documents.1320 Mountain View Dr.0013-2020-BCHO (21)WELS Markup #2 1320 Mt View
Page: IR2.00 - IRRIGATION PLAN
Author: rickma
Date: 6/11/2020 9:32:03 AM
File Name: Irrigation Plan Set.1320MountainViewDrive.Permit
CO#1 REV1.2020.04.pdf
As per WELS Section 5.2.7, "Where feasible, trees shall be placed on separate valves from shrubs, ground covers, and turf grass to
facilitate the appropriate irrigation of trees". Revise plans accordingly in all instances.
IR2.00 - IRRIGATION PLAN (1)
1
2
5
44
6
6
6CONTROLLER
120 VAC POWER REQUIRED
POC
SIZE: 1-INCHPRESSURE: 75 PSIFLOW: 12 GPM MO
U
N
T
A
I
N
V
I
E
W
D
R
I
V
E
60
.
0
'
R
.
O
.
W
.
A110.0
Native
1"
A2Drip
Tree
1"
A311.9
Native
1"
A412.2
Native
1"
A118.90
Turf
1"
A129.69
Turf
1"
A13
Drip
Shrub
1"
A10Drip
Shrub
1"A9Drip
Shrub
1"
A5
11.6
Turf
1"
A6Drip
Shrub
1"
A75.21
Turf
1"
A8Drip
Shrub
1"
A
F
B
B
B
B
B
B
B
B
B
M
M
M
M
M M
M M
M M M M
K
K
K
O
O
O
M SST
SST
SST
SST
SST
RST
LST
SST
K
LST
RST
SST KK
B
B
K
K
K
K
SST
R
R
R
B
UP SPRAY SPRINKLER:SURE: RADIUS:W (GPM):
RAIN BIRD RD1806-S-P30 W/U-SERIES 8 NOZZLE30 PSI 8 FEETQ-0.26 H-0.52 F-1.05
UP SPRAY SPRINKLER:SURE: RADIUS:RAIN BIRD RD1806-S-P30 W/U-SERIES 10 NOZZLE30 PSI 10 FEET
ATION CONTROLLER UNIT WITHWIRELESS RAIN SENSOR WR2-RFCTROLLER A: RAIN BIRD ESP-LXMEF
1
2
3
THE IRRIGATION SYSTEM POINT-OF-CONNECTION (POC) SHALL BE TO THE POTABLE WATER SERVICE LINE (DOWNSTREAM OF THEMETER INSTALLED BY OTHERS) AT THE APPROXIMATE LOCATION SHOWN. INSTALL BACKFLOW PREVENTION UNIT AND MASTERVALVE ASSEMBLY AS INDICATED IN THE IRRIGATION LEGEND. VERIFY EXACT LOCATION OF POC WITH OWNER'S REPRESENTATIVE
WALL MOUNT THE IRRIGATION CONTROLLER AT THE APPROXIMATE LOCATION SHOWN INSIDE OF GARAGE. COORDINATEELECTRICAL POWER TO THE CONTROLLER WITH THE OWNER'S REPRESENTATIVE. CARE SHOULD BE TAKEN TO INSTALL THEIRRIGATION CONTROLLER IN A LOCATION THAT IS ACCESSIBLE FOR MAINTENANCE. FINAL LOCATION TO BE APPROVED BY OWNER REPRESENTATIVE.
THE IRRIGATION CONTRACTOR SHALL INSTALL A LOCKABLE ISOLATION GATE VALVE ASSEMBLY UPSTREAM OF THE IRRIGATION
CONSTRUCTION NOTES
PR
I
V
A
T
E
CIT
Y
O
F
A
S
P
E
N
1
As per WELS Section 5.2.7, "Where feasible, trees shall be
placed on separate valves from shrubs, ground covers, and
turf grass to facilitate the appropriate irrigation of trees".
Revise plans accordingly in all instances.