Loading...
HomeMy WebLinkAboutFile Documents.430 W Hallam St.0291.2017 (117).ARBKMarkup Summary 6-27-2018 Page Label: A-001 - PROPOSED SITE PLAN Page Index: 5 Checkmark: Unchecked Author: bobn Date: 6/27/2018 9:57:40 AM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Please provide a setback chart which will be used as part of the Zoning Compliance Verification Policy. The purpose of the chart is to provide a measurable distance between veneer and setbacks. In addition provide detailed information and height for items in the setbacks. For example, eave overhangs, fences, site walls, water or fire features, trash enclosures, mechanical equipment, etc. and/or reference the plan sheet upon which this information is provided. Please provide allowed exception language specific to each element set forth in 26.575.020.(E).(5) Allowed Projections into Setbacks. Plan Set.430 W Hallam.2017.11.pdf (19) Page Label: A-101 - ROPOSED CRAWL SPACE PLAN Page Index: 12 Checkmark: Unchecked Author: bobn Date: 6/26/2018 4:38:56 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Interior dimensions of window wells encroaching into setbacks is maximum 3 ft. x 3 ft. Please update all window wells on each plan sheet accordingly. Page Label: A-101 - ROPOSED CRAWL SPACE PLAN Page Index: 12 Checkmark: Unchecked Author: bobn Date: 6/26/2018 4:38:33 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Interior dimensions of window wells encroaching into setbacks is maximum 3 ft. x 3 ft. Please update all window wells on each plan sheet accordingly. Page Label: A-101 - ROPOSED CRAWL SPACE PLAN Page Index: 12 Checkmark: Unchecked Author: bobn Date: 6/26/2018 4:38:52 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Interior dimensions of window wells encroaching into setbacks is maximum 3 ft. x 3 ft. Please update all window wells on each plan sheet accordingly. 5'-0" CESSORY ETBACK "ARDCK 5'-21/8" 15'-27/8"17'-41/2" 13 48 2626 122 TUMBLED CONCRETEPAVER - SNOW MELT;REF LANDSCAPEPEA GRAVEL, TYP.REF LANDSCAPE PROPERTY LINE7904 BLOCK 35 ALLEY 7904ACCESSORY SETBACK LINE Please provide a setback chart which will be used as part of the Zoning Compliance Verification Policy. The purpose of the chart is to provide a measurable distance between veneer and setbacks. In addition provide detailed information and height for items in the setbacks. For example, eave overhangs, fences, site walls, water or fire features, trash enclosures, mechanical equipment, etc. and/or reference the plan sheet upon which this information is provided. Please provide allowed exception language specific to each element set forth in 26.575.020.(E).(5) Allowed Projections into Setbacks. 4'-11" 8" 3'-6" 8" 7'-7" 8" 3'-6" 8" 54 54 AA-301 D C B Interiordimensions ofwindow wells encroachinginto setbacksis maximum 3 ft. x 3 ft. Please updateall window wells on eachplan sheetaccordingly. 3 59'-3"57'-3"16'-0"8"3'-6"8"1'-10"8"3'-6"8"29'-9 3'-6" 8" 3'-6" 8" 54 54 W-1 PROPERTY LINE SETBACK LINE EA-305 6A-204 60 ACCESSORY SETBACK LINE 2 Interior dimensions ofwindow wellsencroaching into setbacks is maximum3 ft. x 3 ft. Pleaseupdate all window wells on each plansheet accordingly. E 77'-7" 75'-7" 16'-51/2" 8" 3'-6" 8" 3'-6"8" 54 54 W-1 BA-302 7A-205 D Interiordimensions of window wellsencroachinginto setbacksis maximum 3 ft. x 3 ft. Please updateall windowwells on each plan sheet accordingly. Page Label: A-201 - ELEVATIONS Page Index: 17 Checkmark: Unchecked Author: bobn Date: 6/27/2018 10:33:56 AM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Please provide a drop down lines and measurements for all height points on each elevation, to the most restrictive grade, as was provided for point 'D'. Page Label: A-301 - SECTIONS Page Index: 22 Checkmark: Unchecked Author: bobn Date: 6/27/2018 1:33:54 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Please explain the space between levels. Is there mechanical and duct work, dropped ceilings? Page Label: A-301 - SECTIONS Page Index: 22 Checkmark: Unchecked Author: bobn Date: 6/27/2018 1:24:07 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf 12 ft Page Label: A-304 - SECTIONS Page Index: 25 Checkmark: Unchecked Author: bobn Date: 6/27/2018 1:43:55 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Please provide a floor to ceiling detail for the garage, and the attic space above the garage, how is it accessed, and the dimensions? Also, please indicate where the attic details are for the remainder of the home? Page Label: Z-001 - ONING SUMMARY Page Index: 90 Checkmark: Unchecked Author: bobn Date: 6/21/2018 2:20:51 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Deck exemption is based on the allowable floor area per R-6; not including the TDR allowance. 3,660 sq. ft. x 15% = 549 sq. ft. 3 4 5 2'-0" 7'-111/4" 10'-01/4" DA-304 24 6262 61 SETBACK LINE C Please provide adrop down lines and measurements for all height points on each elevation, to the mostrestrictive grade, aswas provided forpoint 'D'. 2A-503 W-2 Please explain the space between levels. Is there mechanical and duct work, dropped ceilings? GYM 022 2A-503 A-503 F-5 1 W-2 12 f t F G 23A-505 SETBACK LINE Please provide a floor to ceiling detail for the garage, and the attic space above the garage, how is it accessed, and the dimensions? Also, please indicate where the attic details are for the remainder of the home? Reference 26.710.180 Reference Reference Reference Table 26.575.020-2 Existing Gross (Sq Ft)Existing Floor Area (Sq Ft)Proposed Gross (Sq Ft)Proposed Floor Area (Sq Ft)Reference 0.00 0.00 4,596.75 243.47Level)0.00 0.00 0.00 0.002,361.75 2,475.25 2,684.25 2,607.00evel)477.00 113.50 545.50 170.501,845.25 1,808.50 1,194.50 1,106.50711.25 0.00 501.75 0.005,395.25 4,283.75 9,021.00 4,127.47 4,160 Allowable The following FAR schedule applies to single-family and dulpex uses when developed as the only use of the parcel: 1) Detached residential and duplex dwellings established prior to the adoption of ordinance No. 7, Series of 2005: 100% of the allowable floor area of an equivalent-sized lot located in the R-6 Zone District. (See R-6 Zone District.) Receipt of a development order shall constitute the date the use was established. Replacement after demolition shall not effect a new establishment date for the purposes of this Section. City historic transferable developmentrights shall not permit additional floor area for detached residential and duplex dwellings. 2 TDR's N/A First 250 sq ft exempt Next 251-500 sq ft to exlude 50% of area15% of 4,160 allowable floor area per R-6 + 2 TDR's Deck exemption is based on the allowable floor areaper R-6; not including the TDR allowance. 3,660 sq.ft. x 15% = 549 sq. ft. Page Label: Z-005 - ISTING FLOOR AREA CALCULATIONS Page Index: 95 Checkmark: Unchecked Author: bobn Date: 6/27/2018 2:21:02 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf The existing floor area is over the allowable for the R-6 Zone District and lot size. Please provide a Certificate of Occupancy and accompanying floor plans to substantiate the existing floor area. Page Label: Z-005 - ISTING FLOOR AREA CALCULATIONS Page Index: 95 Checkmark: Unchecked Author: bobn Date: 6/26/2018 4:06:35 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Please explain the exempt shading pattern used for bathroom and kitchen areas. Page Label: Z-006 - FLOOR AREA CALCULATIONS Page Index: 96 Checkmark: Unchecked Author: bobn Date: 6/26/2018 4:45:35 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf 3,660 x 15% = 549 sq. ft. Please verify math and update on Sheet Z-007 also. Page Label: Z-006 - FLOOR AREA CALCULATIONS Page Index: 96 Checkmark: Unchecked Author: bobn Date: 6/26/2018 4:46:25 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf 4133.88 Please amend and update Sheet Z-007 also. Page Label: Z-006 - FLOOR AREA CALCULATIONS Page Index: 96 Checkmark: Unchecked Author: bobn Date: 6/26/2018 4:46:08 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf 246.38 Please amend and update Sheet Z-007 also. Upper Level Floor Area (Sq Ft)1,808.50 Total Existing Floor Area (Sq Ft)4,283.75 Main Level Deck Area (Sq Ft)0.00 Upper Level Deck Area (Sq Ft)231.50 Total Existing Deck Area (Sq Ft)231.50 The existing floor area is over the allowable for the R-6 Zone District and lot size. Please provide a Certificate of Occupancy and accompanying floor plans to substantiate the existing floor area. Please explain the exempt shading pattern used for bathroom and kitchen areas. Exempt per RDS 26.575.020.D.2.a (545.50-250-125) Exempt per RDS 26.575.020.D.4.a (3,450 x 15%) = 517.50 Exempt 0 2,684.50 - 77.25 + 170.50 0 67.25 + 22.25 0 1,194.50 - 86.50 D C 3,660 x 15% = 549 sq. ft. Please verify math and update on Sheet Z-007 also. 2,777.50 1,110.00 4,131.10 4133.88 Please amend and update Sheet Z-007 also. 1,110.00 1,194.50 - 86.50 243.60 2,777.50 1,110.00 4,131.10 4,160 Allowable 246.38 Please amend and update Sheet Z-007 also. Page Label: Z-006 - FLOOR AREA CALCULATIONS Page Index: 96 Checkmark: Unchecked Author: bobn Date: 6/26/2018 4:45:13 PM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf 4,596.75 x 5.36% = 246.38 sq. ft. Please verify math, and update on Sheet Z-007 also. Page Label: Z-206 - HEIGHT OVER TOPOGRAPHY Page Index: 111 Checkmark: Unchecked Author: bobn Date: 6/27/2018 10:40:10 AM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Please provide an additional height point in this area. Page Label: Z-701 - RIOR LIGHTING PL Page Index: 112 Checkmark: Unchecked Author: bobn Date: 6/27/2018 10:48:15 AM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Please provide lighting specifications for all four types of proposed lighting. On this sheet, please clearly identify the location of all types of outdoor lighting proposed. Page Label: Z-701 - RIOR LIGHTING PL Page Index: 112 Checkmark: Unchecked Author: bobn Date: 6/27/2018 10:48:47 AM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Linear lights are not allowable. Page Label: Z-702 - LIGHTING SPECS Page Index: 113 Checkmark: Unchecked Author: bobn Date: 6/27/2018 10:47:01 AM Color: File Name: Plan Set.430 W Hallam.2017.11.pdf Please provide a photo of this type of light, illuminated with fully frosted glass. This light fixture is not approved. 628.25 67.00 906.50 100.50 3,127.75 167.50 5.36% s 4,596.75 243.60 Lower Level Area x Percent Exposed @ 5.36% 2,684.25 -77.25 Exempt per RDS 26.575.020.D.2.a 545.50 170.50 (545.50-250-125) 222.50 Exempt per RDS 26.575.020.D.4.a 501.75 (3,450 x 15%) = 517.50 Exempt F E D 4,596.75 x 5.36%= 246.38 sq. ft. Please verify math, and update on Sheet Z-007 also. 8:12 8:12 -7 3/4" B 12:12 12:12 12:12 12:12 3:12 8 40 45 23'-3 1/4" 53 DGE HEIGHT127'-1 3/8"RIDGE HEIGHT128'-5" RIDGE HEIGHT126'-0" Please provide anadditional heightpoint in this area. 3 4 Please provide lighting specifications for all four types of proposed lighting. On this sheet, please clearly identify the location of all types of outdoor lighting proposed. H 5 WALL MOUNTED LUMINAIRE: 8' ABOVE NATURALGRADE LED ILLUMINATING STRIP: 6" ABOVE NATURALGRADE RECESSED WALL LUMINAIRE: 1' ABOVE NATURALGRADE RECESSED WALL LUMINAIRE: LOCATED WITHINEGRESS WELL A B C D 1 2 3 4 5 6 7 8 9 10 11 UN26 RO WI26 COOF FR EN 60FR FR PA26 PRGR FELinear lights are not allowable. Please provide a photo of this type of light, illuminated with fully frosted glass. This light fixture is not approved. forumphi.com | p. 970.279.4109 | f. 866.770.5585 Aspen: 715 W. Main St, #204 Aspen, CO 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81621 FORUM PHI | 430 W Hallam St Clarifications Zoning ***Numbers correspond with numbering found on comments PDF*** 1. A-001 - Setback Chart provided on sheet A-001. Walls called out are closest to the Setback Line per side of the building. See chart also for height of elements within setbacks and their code compliance. 2. A-101 - Interior lightwell dimensions updated to maximum of 3 ft. x 3 ft. clear to interior finish on sheet A-101. 3. A-101 - Interior lightwell dimensions updated to maximum of 3 ft. x 3 ft. clear to interior finish on sheet A-101. 4. A-101 - Interior lightwell dimensions updated to maximum of 3 ft. x 3 ft. clear to interior finish on sheet A-101. 5. A-201 - The dimensions shown in elevation are for the most restrictive grade per roof, not necessarily per elevation as the most restrictive measurement occurs in one elevation. Table updated to say Most Restrictive Heights Over Topography per discussion with Bob and Claude on 8/24/18. 6. A-301 - The space between levels is to be used for mechanical duct work. Ceiling heights vary to accommodate mechanical duct work. 7. A-301 - Determined as Bluebeam measurement error per discussion with Bob and Claude on 8/24/18. 8. A-304 - Sheets A-303 and A-304 updated to more clearly show attic spaces. All attics are accessible through a pull-down and are therefore exempt from Floor Area Calculations per 26.575.020.D.3.c. Floor plans show attic access per R807.1. 9. Z-001 - Allowable Floor Area table on sheet Z-001 updated to show deck exemption based on allowable floor area per R-6, not including the TDR allowance. 10. Z-005 - See attached email correspondence with Stephen Kanipe showing that the existing home was legally constructed. 11. Z-005 - Sheets Z-005, Z-006 and Z-007 updated to clarify exempt fill patterns. The hatch generated in the bathroom and kitchen areas was graphically incorrect but those areas were not included in any calculations. 12. Z-006 - Math updated. Proposed Main Level Floor Area Calculations on sheet Z-006 updated to show deck exemption based on allowable floor area per R-6, not including the TDR allowance. 13. Z-006 - Math updated on both sheets Z-006 and Z-007 with rounding per conventional practice to the nearest 1/100th. 14. Z-006 - Math updated on both sheets Z-006 and Z-007 with rounding per conventional practice to the nearest 1/100th. 15. Z-006 - Math updated on both sheets Z-006 and Z-007 with rounding per conventional practice to the nearest 1/100th. 16. Z-206 - Sheets Z-201 and Z-206 updated to show additional height point B.1 which is not the most restrictive location. The original point B is the most restrictive and is shown in the chart. Only most restrictive heights are shown on the Height Over Topography table. 17. Z-701 - Sheet Z-701 updated to show correct light fixtures. Sheet Z-702 updated to show all lighting fixture specs. 18. Z-701 - Legend on sheet Z-701 updated to no longer show linear lights. There are no linear lights for this project. 19. Z-702 - Photo of similar fixture and bulb with full frosted glass and illuminated on sheet Z-702. Jordan Cunningham <jcunningham@forumphi.com> Fwd: 430 W Hallam ­ Verification of Existing Construction and FAR for Zoning Department  1 message Kara Thompson <kthompson@forumphi.com>Thu, Sep 13, 2018 at 5:29 PM To: Jordan Cunningham <jcunningham@forumphi.com> See thread below to reference in zoning comment re certificate of occupancy  --  Kara Thompson Sr Project Architect AIA | NCARB   Architecture | Interiors | Planning   forumphi.com | p. 914.494.8698 | f. 866.770.5585 Aspen: 715 W. Main Street, #204 Aspen, CO 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81621   CH&L | 2018 Home of the Year Finalist  Mountain Living | 2018 Top Mountain Architects & Designers PSMJ | 2018 + 2017 Circle of Excellence Award  AIA Colorado | 2018 Associate of the Year   AIA Colorado | 2017 Young Architect of the Year  Outside Magazine | 2017 + 2016 #1 Best Place to Work        ­­­­­­­­­­ Forwarded message ­­­­­­­­­  From: Bob Narracci <bob.narracci@cityofaspen.com>  Date: Thu, Sep 13, 2018 at 3:12 PM  Subject: RE: 430 W Hallam ­ Verification of Existing Construction and FAR for Zoning Department  To: Stephen Kanipe <stephen.kanipe@cityofaspen.com>, Kara Thompson <kthompson@forumphi.com>      Thank you Stephen.   Kara, please let me know when the responses/revisions are submitted for review.   Take care, Bob Narracci     Bob Narracci, AICP Community Development Department Zoning Administrator   130 S. Galena St. Aspen, CO 81611   P: (970) 429­2754 www.cityofaspen.com   www.aspencommunityvoice.com            Notice and Disclaimer: This message is intended only for the individual or entity to which it is addressed and may contain information that is confidential and exempt from disclosure pursuant to applicable law.  If you are not the intended recipient, please reply to the sender that you have received the message in error and then delete it.  Further, the information or opinions contained in this email are advisory in nature only and are not binding on the City of Aspen.  If applicable, the information and opinions contain in the email are based on current zoning, which is subject to change in the future, and upon factual representations that may or may not be accurate.  The opinions and information contained herein do not create a legal or vested right or any claim of detrimental reliance.   From: Stephen Kanipe   Sent: Thursday, September 13, 2018 2:54 PM  To: Kara Thompson <kthompson@forumphi.com>  Cc: Bob Narracci <bob.narracci@cityofaspen.com>  Subject: Re: 430 W Hallam ­ Verification of Existing Construction and FAR for Zoning Department   Bob,  I reviewed the extensive permit file for 430 W. Hallam. It appears squeaky clean from the time the city began keeping building records.  There is reason to have confidence in the as built drawings to establish the existing residence was legally constructed.  Stephen    Sent from my iPhone   On Sep 13, 2018, at 10:49 AM, Kara Thompson <kthompson@forumphi.com> wrote: Hi Stephen,      The other week, we briefly spoke about the existing permit documentation for the residence that is currently constructed at 430 W Hallam Street.  As part of our scrape and replace permit for that lot, the Zoning Department is requesting that we provide documentation that the existing house was legally constructed at its current floor area.  They requested a Certificate of Occupancy for the structure which the City does not have a record of.  There is a building permit in the City’s files for the existing house, but it is not signed by the City.  There is an approved building permit for an addition to the existing residence that was approved a few years after construction.   Here is the link to what the permit coordinators sent us for the City’s documentation for the structure.   https://www.dropbox.com/sh/gmkmevymjb07drp/AACQM­LgQGKinhoR6gcMdVd9a?dl=0   Would you be able to provide an email or a letter to the Zoning Department stating that the existing residence was legally constructed?    Thanks,  Kara     ­­ --  Kara Thompson Sr Project Architect AIA | NCARB   Architecture | Interiors | Planning   forumphi.com | p. 914.494.8698 | f. 866.770.5585 Aspen: 715 W. Main Street, #204 Aspen, CO 81611 Basalt: 104 Midland Ave, #202 Basalt, CO 81621   CH&L | 2018 Home of the Year Finalist  Mountain Living | 2018 Top Mountain Architects & Designers PSMJ | 2018 + 2017 Circle of Excellence Award AIA Colorado | 2018 Associate of the Year  AIA Colorado | 2017 Young Architect of the Year Outside Magazine | 2017 + 2016 #1 Best Place to Work