Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.1001 E Cooper Ave.0194.2019 (10).ARBK
mata -ALL NEW VENT TERMINATIONS EXISTING VERIFY ALL EXISTING design TO BE NO HIGHER THAN MIN I 1 I I CONDITIONS company FLAT ROOF UNIT 5 REQ'D BY MECH CODE OR UNIT 5 IlL DIMENSIONS PRIOR TO GICONDITIONLOCALLY CPRACTICES.CEPTED �W 1 GIc CO _ �j---- FFIIXTUR SG OR BUILT-INS mat970.274.6011. -ALTERNATE TERMINATIONS IN I SEE STRUCTURAL Closet 1 I II�I }II I SOFFITS WITH HOA APPROVAL DRAWINGS FOR NEW EXISTING NEW CLOSETS I -TERMINATION LOCATIONS I 3"/12" FRAMING EXISTING GWB ON I I Project Address: SHOWN ARE DIAGRAMMATIC; I WALLS TO 2X FURRING Closet P REMAIN LAYOUT OF 3 1001 E Cooper Ave FINAL LOCATIONS TO I EXISTING NEW BEAM ABOVE Aspen,CO DETERMINED ONCE EXISTING PORTION OF ROOF I . PER STRUCTURAL j , BATHROOMS STRUCTURAL CONDITIONS ARE I SLOPE TO BE LOWERED REPLACEIo REPLACEID V UPDATED 9 P EXPOSED I z�1� F Master Bedroom z N Legal Description: 0CDOUBLE Unit 1,The Villager I NEW TYPE X GWBfe e Bath 3 F w w 1 Townhouse Condominiums i-BATH VENTS PORTION OF X C71 EE NEW BARN DOOR NEW BUILT-INS, W G EE 1 E ON NON-COMB R c7 w i w_ Owner: I NEW ROOF w FURRING PER 6/201 w �V PLATINUM IRREV TRUST I EXISTING APROX 21 S.F. sn PATCH Bedroom 2 TUB-SHOWER SAN DIEGO CA I FLAT ROOF NEW — ROOF EXISTINGS SA 4 WALLS 11 I I MATCH EXISTING r EXISTING PROJECT TEAM: EXTEND FLOOR ASSEMBLY A201 REPLACE I I Os— DRAIN OF Ne Ba.h ` ' I WALLS TO Architect: EXG SKYLIGHT EXISTING `, O C l REMAINMata,I BATH VENT Martin Design Architect Mato Design Company ROOF TO NEW - — E NEW '` NEW WALLS g @ PORTION 1 WINDOW 970-274-6011 matadesi n maacom M BATH %�'�' I- NEW POCKET DOOR UNIT 1 UNIT 2 ''LAYOUT N ew Bat 2 General Contractor: DRYER REPLACE Max U value of.55 U DATED -- 'replace 3 existing skylights — Hall 1 Office Justin Soderberg EXHAUST \ FURN&WH DIRECT EXG SKYLIGHT STEAM ;above w/fixed units , i` Aspen Construction Management,Inc 1` 12 LAUND RM VENT 970-274-3236 Justin@acmaspen.com VENT FLUES 4"Curb required per IBC 2405.4 SHOWER I V®E IN DOOR.COMB 3 o. 1 DUCT BELOW/ New$hwr AIR PER IMC 703 Structural Engineer. Jack Aright Shall be of an approved material SEAT SHELF ABOVE - ' Albright&Associates,Inc bb per IBC 2405.2 , Mir - EXISTING BRICK WALLS i' ' WOOD - = /, I�rn1a •� _ 970-927-4363 m /7 ' N Dining FLOORING S� C I jack@albright-associates.com BETWEEN UNITS: it o to _ 2 WYTHES OF 4"BRICK NEW WATER r 3"/12" lo— NEW ` UNIT 2 w w 3"/12" NM w Q 4HR OR GREATER HEATER UNDER CLOSE!" S' o EXISTING NEW w I a WINDOW ' THROUGHOUT STC 52 OR GREATER STAIRS W/HOT 0 FLAT ROOF E, TING EXISTIN +NWATER RE-CIRC NEW WOOD a 0 b. Stair I I i�T� , Stair Foyer 7HouGH FLOORING ouT I- SMOKE ALARMS AND EXISTING BRICK WALLS NEW CS CARBON MONOXIDE z LL w REPLACE EXISTING GUARDRAIL ACCESS 1.DV.' DETECTORS REQUIRED O /^ c i "n r •UP BETWEEN UNITS: Z &HANDRAIL TO MEET IBC CH10 2 WYTHES OF 4"BRICK > w \I REQUIREMENTS c9 UNIT 2 =4HR OR GREATER PER THROUGHOUT DWELLING EX{STING -—— w t} IBC 722 4 1 UNIT PER CITY OF ASPEN CHIMNEY NEW STEEL BEAM ABOVE PER EXG C.S. MUNICIPAL CODE 8.15 —�—w 30" / �jy NEW BEAM LL—Z REF // STRUCT DRAWINGS -.- i ♦C/�1 ACCESS ABOVE PER =SIC 52 OR GREATER Kitchen / RELOCATED STRUCT o m NEW — O a RELOCATED sA n—L r X-' GAS« 224I 4 REPLACE KITCHEN LL LIGHTS @ 8'-4" I I w ,'. ---- Living Area Entry —m g 2 KITCHEN- N I Mw — Bedroom 3 NEW TILE FLOOR a 0 LAYOU w-2 _, UPDATED — — i • a _ Wes/ O l7 T' REPLACE EXG DOOR O0 EXISTING IA I SEE NOTES#1 PLANS STREET FACADE r UNIT I UNIT 2 MAIN Deck /fit \ EGRESS — 0 „ O REPLACE EXISTING DECK SURFACE ' O „ (DECK pECK ABOVE ENTRANCE7t�-s��,„� ��/ / AND LOW-WALL SURFACES L �� f Lam" _ 09/16/2019 0 — NORTH Roof Plan NORTH / NORTH -Level 1 Proposed FOR(OOkCxBIPiYli10E O 1/4"=1'-0" O-Level 2 Proposed 1/4"=1'-0" iustinh 1/4"=1'-0" ' Thickness: component: R-value: 2015IECCTable R402.1.2(as amended byCi of Aspen Ordinance 40,2016 NEW ROOF MEMBRANE tY P A B OutsideWater-proof r layer 0.17 PATCHED INTO EXISTING WOOD CRAWL Water-proof membrane 0.21 Permit Update ROOF PER HOA GUIDELINES s/8" Sheathing 0.77 FRAME MASS BASEMENT SLAB SPACE EXISTING ROOF NEW STR PLY TO MATCH EXISTING 4" Closed-cell spray foam28CLIMATE FENESTRATION SKYLIGHT CEILING WALL WALL FLOOR WALL R-VALUE WALLNEW PORTION OF ROOF 5/A201 /0/ —condensing surface— ZONE U-FACTOR U-FACTOR R-VALUE R-VALUE R-VALUE R-VALUE R-VALUE &DEPTH R-VALUE 08 October,2019 51/4" Fiberglass Butt(high density) 21 -EXTEND EXISTING ROOF DRAIN 20+5 or , xAPPROX EXTENT OF ROOF -PATCH INTO EXISTING ROOF PER 5/8" Gypsum board 0.56 7 0.28 0.55 49 13+10k 19/21 38 15/19' 10,4 ft4 15/19` Inside air layer 0.65 TO BE LOWERED. HEIGHT �� HOA GUIDELINES MIN R 49Table Footnotes: TO BE FIELD-DETERMINED 'r�►✓' -R49 INSUL'N PER IECC INSULATION PERR402 Rlexterior)=0.17+0.21+0.77+28=29.15 c."15/19"means R-15 continuous insulated sheathing on the interior or exterior of the home or R-19 cavity insulation at the 1 BASED ON VIEWPLANE ,:-, -�ii/ "NON-VENTED CLOSED CELL SPRAY- R(total)=29.15+21+0.56+0.65=51.36 interior of the basement wall."15/19"shall be permitted to be met with R-13 cavity insulation on the interior of the basement `�� EXISTING ROOF T(inside)=70 deg F wall plus R-5 continuous Insulated sheathing on the interior or exterior of the home."10/13"means R-10 continuous insulated 5 1/4" /4 HD FIBERGLASS BATT 7loutside)=-16 deg F sheathing on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. II� �r —II Roof Plate Tlinterface)=R(exterior)/R(total)x IT(inside)-T(outside)]+T(outside) d.R-5 shall be added to the required slab edge R-values for heated slabs.Insulation depth shall be the depth of the footing or 2 - 115'-6 3/4" T(interface)=29.15/51.36 x[70-19.8]+19.8) feet,whichever is less in Zones l through 3 for heated slabs. I I • ( EXISTING NON-BEARNG T(interface)=48.3 g.Or insulation sufficient to fill the framing cavity,R-19 minimum. II WALLS TO BE REMOVED 7,, 2X TO MATCH EXISTING 16"OC MAX h.The first value is cavity insulation,the second value is continuous insulation,so"13+5"means R-13 cavity insulation plus R-5 @ R(exterior)=0.17+0.21+0.77+28=29.15 continuous insulation. I I NEW FURRING 6/A201 it R(total)=29.15+21+0.56+0.65=51.36 1.The second R-value applies when more than half the insulation is on the interior of the mass wall. New M.Beth I I Y 5/8"TYPE X GWB Tlinside)=70 deg F 1 KAH N T(outside]=-16 deg F I I EXISTING ROOF ASSEMBLY TO BE T(interface)=R(exterior)/R(total)x[T(inside]-T(outside)]+T(outside) II / CONVERTED TO FLOOR ASSEMBLY ORoof/Ceiling Assembly T(interface)=29.15/51.36 x[70-19.81+19.8) 70151BC Residential Code Referen ` 1 1/2"=1'-0" T(interface)=48.3 DCa m°"°"°°°° _. Municipal°°.15 "s — e I I I I -Level 2 Pro osed a � �detector noM�.M�, 10T-91/2 r I �EXISTING 2-WYTHE BRICK WALL ©s � °" e�°,, ,,"n,� - _ 1 NEW WALLS 5/8"GWB E/S ON 2X zn Bedroom 2 1 �� MATCH EXISTING FURRING ® s"w° i I E• EXISTING 2-WYTHE g / �� New 6��9 3 • — BRICK WALL / / ��5/8"TYPEXGWBON _ I Villager Unit 1 II UNIT 2 NON-COMB FURRING I I • n , 1 _-Level 1 Proposed hi " / /O / PER 803.13 WITH — 100'-0" �1 FIREBLOCKING PER 718 ol z Existing Crawlspa:e Le‘ :)e1 ph Proposed Floor ANEW I 96'-4" Plans EXISTING ®Section 1 / 1/4"=1'-0" Parcel ID# 273718233504 s o o � UNIT2 / UNIT �p��1� i Q iidkol91,wh9 2, A201 r ©Furring @ Unit Separation Wall a Scale As indicated 1 1/2"=1'-0" ZONING