Loading...
HomeMy WebLinkAboutFile Documents.427 Rio Grande Pl.0016.2019 (5).ACBK 0016-2019-ACBK_BuildingComments_1 NICK Plan Set.Arch.425 Rio Grande Place.2019.03.pdf(47) Page: !CVR File Name: NICK Plan Set.Arch.425 Rio Grande Provide existing plans. Place.2019.03.pdf Subject: PlanCheck Author: nickt Provide existing plans. Color: • I-- ==1: I=I I I__- Page:A0.3-CODE ANALYSIS File Name: NICK Plan Set.Arch.425 Rio Grande Refine the frontage area calculations. Measure each Place.2019.03.pdf = wa Subject: PlanCheck plane and give credit for alleys. Author: nickt Color: ■ Page:A0.3-CODE ANALYSIS File Name: NICK Plan Set.Arch.425 Rio Grande Provide plumbing fixture count Place.2019.03.pdf chart for the lower and main Subject: PlanCheck levels. MIDDLE LE/EL fl est,ha?,tor - Author: nickt the lower and male t]'IPPL Color: • levels. Page:A0.3-CODE ANALYSIS Calculate the number of required File Name: NICK Plan Set.Arch.425 Rio Grande Place.2019.03.pdf fixtures on a floor in a mixed Subject: PlanCheck occupancy by not rounding up Author: nickt until after adding all the Color: • occupancies together. For example: Women B occupancy: w1.09 occupants/25= .36 r=-1 Women A occupancy: 106 occupants/65= 1.63 .36+1.63=1.99 rounds to 2 Page:A0.3-CODE ANALYSIS BUILDING CODE ANALYSIS „_...,�, File Name: NICK Plan Set.Arch.425 Rio Grande S1 requires the firewall - Place.2019.03.pdf separating the Rio Grande to be Subject: PlanCheck 3 hour. 2015 IBC 706.4. ; gym m2 Author: nickt Color: • Page:A0.3-CODE ANALYSIS File Name: NICK Plan Set.Arch.425 Rio Grande Circulation needs an occupancy -- ==®® Place.2019.03.pdf type. 2015 IBC 508.2.1 ®ao_=_ r Subject: PlanCheck ve ®@ n Author: nickt ...En _ Color: ■ -®__i- u 0 4 Page:A0.3-CODE ANALYSIS 136/2=68. There are 68 males File Name: NICK Plan Set.Arch.425 Rio Grande and 68 females on the middle Place.2019.03.pdf Subject: PlanCheck level per your occupant load Author: nickt calculation. ©s1 Color: ■ Asa cm: s ©s �s Page:A0.3-CODE ANALYSIS File Name: NICK Plan Set.Arch.425 Rio Grande Parking occupant load density Place.2019.03.pdf should be 200 sqft per person Subject: PlanCheck (gross). 2015 IBC table 1004.1.2 Parking sccupani loatl Author: nickt tlenaM1y sM1oultl be 200 Voper person L// (gmss).20151BC cable Color: ■ T LA�004.iu2 w.ii..TS .A(SF) (55iPE155017) ,12 500 46 ;__I : I . I Page:A0.3-CODE ANALYSIS File Name: NICK Plan Set.Arch.425 Rio Grande Finish your documentation and _ - _ - -- .- .__ Place.2019.03.pdf calculations demonstrating ___ . compliance with 2015 IBC �� Subject: PlanCheck I _ _ _ TII� \„"' Author: nickt 506.2.4 and 508.What you show 4 here is incomplete. Break it _ v= r ` Color: ■ down by story. Demonstrate that �,zu�..-s.�E:`. the ratios of each story add up to 1 or less. Page:A0.3-CODE ANALYSIS Provide totals for each floor level File Name: NICK Plan Set.Arch.425 Rio Grande ® Place.2019.03.pdf for each occupancy type. For __ 0 Subject: PlanCheck example,for the upper level, add Author: nickt up all of the B occupancies. Color: ■ Also, provide a separate chart I 1 T � for the Rio Grande. It is a — __ - separate building. Page:A0.3-CODE ANALYSIS Call out the 1 hour assemblies to _ - = File Name: NICK Plan Set.Arch.425 Rio Grande Place.2019.03.pdf be used at each instance.Apart -- Subject: PlanCheck from this statement it is not clear Author: nickt on the plans that all bearing Color: • structure must be 1 hour rated. �._ _---• Please make it clear in the assemblies/plans/and or sections. Page:A0.3-CODE ANALYSIS File Name: NICK Plan Set.Arch.425 Rio Grande Revise to the following codes: _ Place.2019.03.pdf -2017 National Electric Code Subject: PlanCheck -ICC A117.1-2009 Accessibility Standard Author: nickt Color: ■ 7,, Page:A0.3-CODE ANALYSIS File Name: NICK Plan Set.Arch.425 Rio Grande This is not worded right, let's - a Place.2019.03.pdf make it clearer.You have two Subject: PlanCheck buildings(Library+Garage+Civic) Riff`"' Author: nickt and (Rio Grande)separated by Color: • a 2 hour fire wall. ___ -22,±44 The Library+Garage+Civic building uses separated occupancies(508.4)to separate the Library from the Garage+Civic.This requires a preexisting 1 hour fire barrier. The Garage+Civic portion uses non-separated occupancies (508.3). The mechanical and trash rooms use incidental use(509)to separate from the rest. Page:A0.3-CODE ANALYSIS File Name: NICK Plan Set.Arch.425 Rio Grande Provide a floor plan showing the vo = Place.2019.03.pdf occupiable exterior area. If not _ Subject: PlanCheck an enclosed gathering space, -- = _ -- Author: nickt don't count occupant load. m - Color: • ve LL LL a2g Page:A0.4-LIFESAFETY PLANS File Name: NICK Plan Set.Arch.425 Rio Grande Revise to the following codes: Place.2019.03.pdf -2017 National Electric Code Subject: PlanCheck -ICC A117.1-2009 Accessibility Author: nickt Standard 0 Color: ■ \ nGnl „Rw II. : . • Page:A0.4-LIFESAFETY PLANS '°:`._ . , „\ The fire barrier exit enclosure ■Illllllllllllui ^ w File Name: NICK Plan Set.Arch.425 Rio Grande �u doesn't stack.All supporting :t.,� <= Place.2019.03.pdf construction and slab must be 2 Subject:nickt PlanCheck ���,1111111 hour rated. Clearly detail this. I�soba Author:Color: • Your 2hr rated structure plan is N^..,:=. ii incomplete. ( h ��+� w _ Page:A0.4-LIFESAFETY PLANS IIIME E t!:,J File Name: NICK Plan Set.Arch.425 Rio Grande Detail the exit discharge egress mw court and demonstrate __ Place.2019.03.pdf 1 ” . Subject: PlanCheck compliance with the provisions Author: nickt of 2015 IBC 1028. p Color: ■ OMAIN LE Page:A0.4-LIFESAFETY PLANS File Name: NICK Plan Set.Arch.425 Rio Grande The fire wall is required at all p. Place.2019.03.pdf levels where the two buildings h connect. Indicate the 3 hour n Subject: PlanCheck requirement(due to there being 8ii Author: nickt Color: • S1). r LAY LA FilePage:Name:A0.4-NICK PlanIFES Set.Arch.4FETPLANS 25 Rio Grande Measure all travel paths Place.2019.03.pdf rectilinearly(not diagonally). O ?... MR LEVEL FLOC Subject: PlanCheck Common path travel distance GI • AM Author: nickt maximum is 100'for a ' 4' * �K Color: • sprinklered B occupancy(2015 Iw , ''' '• :M b'db, IBC 1006.2.1). NEEI is 4 IF t 401 --- Page:A0.4-LIFESAFETY PLANS \ File Name: NICK Plan Set.Arch.425 Rio Grande The mechanical room is greater FLOOR PLAN S Place.2019.03.pdf than 500 sqft and has equipment :::N E ° _ Subject: PlanCheck greater than 400 kBtu, requiring Author: nickt the following: °�� Color: ■ „�sa"o=. , 1.Two exits required per 2015 M, 1` IBC 1006.2.2.1.The second exit �_ currently requires traveling �� ". through an intervening space (storage). Provide a discernible path of travel through the storage per 2015 IBC 1016.2 item 2. 2. It is an incidental occupancy per 2015 IBC 509. Provide either 1 hour fire barrier/horizontal separation or sprinklers and smoke barriers(including doors sealed in accordance with NFPA 80). Page:A0.4-LIFESAFETY PLANS File Name: NICK Plan Set.Arch.425 Rio Grande Provide and show two ER LEVEL FLOOR PLAN accessible means of egress from _0,, Place.2019.03.pdf Subject: PlanCheck the middle level and one from Provide and show two the lower level. 2015 IBC 1009. accessible means of egress Author: nickt from the middle level and one Color:the lower level.2015 IBC Color: ■ 1009. POLE PROVIDED TO PROTECT NING.RE:5/A6.2 Page:A0.4-LIFESAFETY PLANS File Name: NICK Plan Set.Arch.425 Rio Grande Measure travel distance from the Place.2019.03.pdf furthest point starting 2'off the Subject: PlanCheck wall. Max travel distance for Author: nickt storage in a single exit story with i 2015 Color: • sprinkler increase is 100' per r_° IBC table 2015 IBC table 1006.3.2(2) footnote b. I .-,.111111 1 1 1 1 I, ,I 1 gliii Page:A0.4-LIFESAFETY PLANS File Name: NICK Plan Set.Arch.425 Rio Grande The trash enclosure is an ��q_ incidental use requiring either 1 Place.2019.03.pdf Subject: PlanCheck hour fire barriers or sprinklers Tne,nsn enclosure is an trraenai HRe cons —\ Author: nickt and smoke barriers. Door must rep' Color: • be sealed from smoke and self i_FI "„a`F°ao.Rom °'1II y �; B closing or automatic closing N .-0,-".i—.;I upon detection of smoke per ::r„,,,t- __----: : NFPA 80. (2015 IBC 509.4.2) I t=i - n Page:A0.4-LIFESAFETY PLANS File Name: NICK Plan Set.Arch.425 Rio Grande Detail each shaft in section view, Place.2019.03.pdf including the exit enclosure, Subject: PlanCheck elevator, and chases. Show and Author: nickt demonstrate compliance for the Color: • following: -Continuity(2015 IBC 713.5). _� Shaft enclosures shall be constructed as fire barriers or horizontal assemblies, or both, and shall have continuity in accordance with Section 707.5 for fire barriers or Section 711.2.2 for horizontal assemblies. Fire barriers shall extend from the top of the foundation or floor/ceiling assembly below to the underside of the floor or roof sheathing, slab or deck above. Such fire barriers shall be continuous through concealed space, such as the space above a suspended ceiling. -Detail and provided listed assemblies for joints and voids at intersections(Sections 707.8 and 707.9) -The supporting construction for fire barriers and horizontal assemblies shall be protected to afford the required fire-resistance rating of the fire barrier supported. (707.5.1 and 711.2.3) -Shafts that do not extend to the bottom of the building or structure shall comply with 713.11 -A shaft enclosure that does not extend to the underside of the roof sheathing, deck or slab of the building shall be enclosed at the top with construction of the same fire-resistance rating as the topmost floor penetrated by the shaft, but not less than the fire-resistance rating required for the shaft enclosure. 713.12 Elevator enclosures must also comply with Chapter 30. Page:A0.5-LIFESAFETY SECTIONS File Name: NICK Plan Set.Arch.425 Rio Grande Enlarge this section detail of the '**" fire wall to demonstrate j Place.2019.03.pdf breakaway anchors so that 4 ■7 � Subject: PlanCheck M' Author: nickt either side can fall down without �' \ Color: • affecting the wall. 2015 IBC 706.2 Il mll II IIGI=11 iEWALL SECTION Page:A0.5-LIFESAFETY SECTIONS 1 hour roof rating must extend File Name: NICK Plan Set.Arch.425 Rio Grande 10'per 201 IBC 706. 6.1 '•• Place.2019.03.pdf Subject: PlanCheck exception. Author: nickt ,,„ ; /ems Color: ■ na,l, 11Ilml OFIREWALL SECTION R RA;EO FOOP1E%iEND54 Page:A0.5-LIFESAFETY SECTIONS -RH—ER°GREGGW,WO RE E,«R ALL File Name: NICK Plan Set.Arch.425 Rio Grande Fire wall must be 3 hour due to �°ULD83' the S1 occupancy. 2015 IBC ft FIRE NULL SEPARATING RI, Place.2019.03.pdf oNE�'GNs''''''` Subject: PlanCheck 706. Nft UL aUaOS EXISTING GARAGE STRUGNRE— Author: nickt Color: ■ Fire well must be 3 na".e"a,o ua sl ccupancy.2U151BC ]Ufi. OFIREWALL SE I Page:A0.6-2HR RATED STRUCTURE —0 The exit enclosure on the middle File Name: NICK Plan Set.Arch.425 Rio Grande Place.2019.03.pdf level does not stack over the 1 T IN Subject: PlanCheck main below. Protect all structure - P8 - - Author: nickt � supporting it. 2015 IBC 707.5.1 -- PO p,filfi",o, `I4 ��71 Color: ■ IIIIIIIII :u � � ��= - PB I. l fi • p I I 1 1 , #*0. Page:A0.6-2HR RATED STRUCTURE Protect all structure supporting _10 I_ File Name: NICK Plan Set.Arch.425 Rio Grande pp g kW Place.2019.03.pdf this shaft.You are missing �• _r '--0 L Subject: PlanCheck some. 2015 IBC 707.5.1 in■■ m Author: nickt .� .1--f�f�-� --0 Color: ■ -0 --t1 n MAIN LEVEL FLOOR PLAN Page:A1.1 -ARCHITECTURAL SITE PLAN File Name: NICK Plan Set.Arch.425 Rio Grande Provide an imaginary lot line Place.2019.03.pdf between the Mill Street Condos ��� 1 and the Civic building. The Subject: PlanCheck o location of the line must be fi\ ' 0 Author: nickt ', t�► %. Color: ■ located so as to not put the l rnilan �%.r , r� condos out of compliance.The r' existing Mill Street Condos are Type VA construction and have I. r� • � ,�� ,� windows on that side.The I survey shows a 5'restriction around the condos. Provide the distance to the imaginary line from the new Civic building and demonstrate compliance with 2015 IBC table 602 and section 705. 0 111 bi" <-`A r Page:A2.2-MAIN LEVEL REFERENCEFLOOR PLAN Provide an enlarged plan of the iri���A— File Name: NICK Plan Set.Arch.425 Rio Grande g �� egress court exit discharge. =mom =NM Place.2019.03.pdf lid ° 1 )I • Subject: PlanCheck Show all slopes of walkways and FAIFn AVIVIEU Author: nickt widths. Demonstrate compliance 1I®1�F1�� Color: • with 2015 IBC ch 10 and 11. I ,= i ; / Page:A2.6-LOWER LEVEL PARTIAL FLOOR PLAN �'I; 4'= !! / File Name: NICK Plan Set.Arch.425 Rio Grande Verify all existing doors in the stair enclosure are 90 minute fire i , ! ; Place.2019.03.pdf 1 j al !.._.__._..____.. ._!_._.___.____ Subject: PlanCheck rated. 2015 IBC 716. ---- i Author: nickt Ve e he sWl ellaxl encbeur cl sums Color: • In M1e r re 00 minute fire 21etl.20151BC]t6. o:L°_ 1 i I Page:A2.6-LOWER LEVEL PARTIAL FLOOR PLAN Add all stair doors(SOOX series) L.. .. ' File Name: NICK Plan Set.Arch.425 Rio Grande ' F; N Place.2019.03.pdf to the door schedule. 90 minute � nee ell ereir seers fire rating required. 2015 IBC ($00X5B,,eu). to VESTIBULE i 1 Subject: PlanCheck i al 0emeame so reI urefIrred e.r9C DI ' I I Author: nickt 1023.3.1 ] 0]3.3.1 L Color: • 1 1 i WEL n3ol10 IF' a 1 Page:A2.8-MAIN LEVEL PARTIAL FLOOR PLAN-AREA B ally Provide a barrier at the level of m File Name: NICK Plan Set.Arch.425 Rio Grande exit discharge to prevent _N! - Place.2019.03.pdf ' ` It ;, occupants from traveling past Subject: PlanCheck the exit discharge. 2015 IBC _' @ Author: nickt 1023.8. /o,s. Color: • e Is ,+e /'' :1 I . �l e„� a. Page:A2.12-MIDDLE LEVEL PARTIAL FLOOR PLAN- LT'-1-- — :i i W® _- AREA C Update mechanical plans to - depict new boiler flue routing File Name: NICK Plan Set.Arch.425 Rio Grande TIT: o Place.2019.03.pdf and termination location. I 1.11111111 Demonstrate compliance with -, Subject: PlanCheck .-r ..-2__, kff Author: nickt 2015 IMC 501. Color: ■ Page:A6.1 -ENLARGED CORE PLANS File Name: NICK Plan Set.Arch.425 Rio Grande Indicate location of the elevator Place.2019.03.pdf machine equipment. Subject: PlanCheck Demonstrate compliance with Indicate locehon of the elevator Author: nickt 2015 IBC ch 30. machine equipment.Demonstrate' compliance with 2015 IBC ch 30." l/Y/ Color: ■ I OI5 NOTE:MINIMUM 90-FOR RALIEL ELEVATOR D FOR f ALL EVnTOR DOORS. I I Page:A6.2-ENLARGED STAIR PLANS File Name: NICK Plan Set.Arch.425 Rio Grande Laminated glass required at Place.2019.03.pdf guardrails. 2015 IBC 2407. °°"7.7a2p1$10CCl°,1 15 Subject: PlanCheck Author: nickt Color: ■ e ..__c � i N 75 . .......... RE seer $ . _ ,o m Page:A6.2-ENLARGED STAIR PLANS ' `�" ""°"""`m' "" File Name: NICK Plan Set.Arch.425 Rio Grande The smallest radius of the .r ""`-"" "`m'��"""�„�, Place.2019.03.pdf curved stair may not be less than twice the minimum required © D Subject: PlanCheck stair width. Minimum stair width O'1'' Author: nickt L�!!s Color: ■ is 44" (1011.2)so minimum f 11/ r- radius is 88"per 2015 IBC II ... _ L.��t 1011.9. O STAIR S002 P Page:A6.2-ENLARGED STAIR PLANS File Name: NICK Plan Set.Arch.425 Rio Grande Show and dimension the curved Place.2019.03.pdf stair walkline and tread depths at Show anadiwensioe he Subject: PlanCheckcurve walk line and at smallest and tread depths at walk line Author: nickt largest location.Also provide a nda`ama"eptdoiaryeat E riser heights. Demonstrate EE ocation.Alsoprovidedser Color: ■ heights compliance compliance with 2015 IBC 1011. pliance with 2015 IBC p loll. ITINUOUS RDRAIL 15 / ® Page:A6.3-PLAZA ELEVATOR PLANS& ELEVATIONS Revise details of the fire wall to II; LI/ ,f I 0 File Name: NICK Plan Set.Arch.425 Rio Grande demonstrate compliance with Place.2019.03.pdf 2015 IBC 706.5(including all i c I It Subject: PlanCheck . .. o..w.. . subsections). Author: nickt ill. Color: ■ ,_........ Page:A6.3-PLAZA ELEVATOR PLANS& ELEVATIONS The walls perpendicular to the File Name: NICK Plan Set.Arch.425 Rio Grande o- ° Place.2019.03.pdf firewall must be capable of . , collapse without affecting the fire 1rm Subject: PlanCheck �' ® �' a1 r. wall. Same with the floor and 17I -®—I .,I FT Author: nickt �''® 1 i` . �I Color: • roof assemblies. Show how you �!i . �I = i 4. 1'-�; il i accomplish this. 2015 IBC 706.2 :LAS.A ELEV PLAN-UPPPERLEVEL o I: .. LEV.PLA"MIDDLE LEVEL I 14, °f , Page:A6.3-PLAZA ELEVATOR PLANS& ELEVATIONS �j LL File Name: NICK Plan Set.Arch.425 Rio Grande The firewall is required at the o es main level as well. Indicate how Pi1OX ©PA^ A A a; Place.2019.03.pdf �_ e o ;. w" Subject: PlanCheck this level complies with the 1 "" Author: nickt requirements of 2015 IBC 706. � ���f6 ^w I D. �/i f I� _.W if itl�i Color: ■ v ..V ea Q P.." nvi.w uuxlea Afi.3 Page:A6.4-ELEVATOR SECTIONS&DETAILS - - }- '" File Name: NICK Plan Set.Arch.425 Rio Grande Detail the intersection of the I Place.2019.03.pdf shaft wall with the horizontal e. ll , Subject: PlanCheck assemblies. i os Author: nickt SIR Color: • ; ''' kill /‘1 1 3 _ ,� Page:A6.6-STAIR SECTIONS AND DETAILS 1 � :j File Name: NICK Plan Set.Arch.425 Rio Grande Show handrails in this section ;x; \ I Place.2019.03.pdf view. 2015 IBC 1014. •-A , Subject: PlanCheck Author: nickt 0. 1 2015�IBC Color: • ,'. 1a14. �� �L�e�i1 1 II Page:A9.1 -ROOF,WALL,AND FLOOR ASSEMBLIES File Name: NICK Plan Set.Arch.425 Rio Grande Provide documentation that the Place.2019.03.pdf roof assemblies are Class A. Subject: PlanCheck This is typically either an ESR or Author: nickt UL report. Revise you roof �rypemblies are Class A.This Is lcsllyellher a"ESR°r ULrep°n., details to match the reports. rRe"isevoa r°et delalls to match the' Color: • r reports.(Ordinance 40,2016J (Ordinance 40, 2016) DB°KIB°- ,FSBN EC rag�,T IA IZr C,FIC UNIT PA/ER REF SANDSETTING BED FILTER FABRIC Page:A10.3-WINDOW SCHEDULE — , --- — File Name: NICK Plan Set.Arch.425 Rio Grande Indicate which windows require "„Ea „"=°,.:S"rEga, ET Place.2019.03.pdf safety glazing per 2015 IBC .wrt„„,m„o°„.„,,,, Subject: safety Glazing windows 2406.4. Revise the window Author: nickt schedule or elevations. =.....t==relzr. - Color: ■ u _ . Page:A10.5-DOOR SCHEDULE File Name: NICK Plan Set.Arch.425 Rio Grande Door 101B is less than 36".All W doors that are part of the means . Place.2019.03.pdf ' Subject: Doors 32"clear of egress must provide 32"clear Author: nickt measured from the face of the fl il `; Color: • door leaf opened at 90 degrees to the face of the doorstop. •I' Revise door schedule to , demonstrate compliance(either ii :21 change to 3'-0"doors or detail how your smaller doors will achieve 32"clear. (2015 IBC 1010.1.1) NICKPlan Set.Civil.425 Rio Grande Place.2019.03.pdf(1) 1,� o. l.__ Page: C5-CITY HALL SHEET INDEX With 26 parking spaces you �{{ I File Name: NICKPlan Set.Civil.425 Rio Grande I'I �ml Place.2019.03.pdf have provided the required 2 0. E Sub accessible parking spaces(both liriiii ,-�_ Subject. PlanCheck iP?„ -'_`_T Author: nickt shown as van spaces). �,; _ Color: • However, currently there is a van —r accessible space in this lot provided for the parking garage ___ which does not have the _ headroom fora van space. Provide a total of 3 accessible parking spaces in this lot: minimum of 2 van and 1 standard accessible. 2015 IBC 1106. Plan Set.Electrical.425 Rio Grande Place.2019.03.pdf(2) a= -o-s1- Page: E3.0-GALENA BASEMENT LEVEL ELECTRICAL 2017 NEC 110.26(C): Provide PLAN - -� s� panic hardware on doors to the l W File Name: Plan Set.Electrical.425 Rio Grande electrical room for the large I __& 1- Place.2019.03.pdf �� fr ®"' Subject: PlanCheck equipment. " Author: nickt Color: ■ 7 III __gyp e' Page: E3.0-GALENA BASEMENT LEVEL ELECTRICAL 0O6ATfG R PLAN Provide details of generator e, �R 80 AT"' File Name: Plan Set.Electrical.425 Rio Grande sizing at this altitude. Aral GAS S Place.2019.03.pdf ' EllGENERATOR a Subject: PlanCheck Provide details of ' . FI Author: nickt aeaedefo,swn9affhs Color: ■ Plan Set.Mechanical.425 Rio Grande Place.2019.03.pdf(5) Page: M2.01 -MECHANICAL BASEMENT LEVEL PLAN r�Rli + 111 �I File Name: Plan Set.Mechanical.425 Rio Grande No through penetrations are 17��_�� 1ry( .-I I� /, Place.2019.03.pdf permitted in the exit ® i�l�mirl k �i`. ®a° passageway. 2015 IBC 1024.6 hawSubject: PlanCheck — n i�+l ' - Author: nickt X vM''-' Color: ■ ; , Am 'k=a 1 .,.,„,,: , ,, , —VI /y j e�l11i I Page: M2.01 MECHANICAL BASEMENT LEVEL PLAN Provide a 2 hour shaft enclosure rn-- File Name: Plan Set.Mechanical.425 Rio Grande iii; � � Place.2019.03.pdf for this duct which penetrates 4 9� 0�� i.-.__, c��j g_ ®l stories. 2015 IBC 717.6.1. I1991 net.u, I Subject: PlanCheck _''C`1m ji° I Author: nickt L..y — I .1-el Color: ■ F1il gli mym If ® u r Page: M2.02-MECHANICAL MAIN LEVEL PLAN r ��� Duct penetrations of the shaft File Name: Plan Set.Mechanical.425 Rio Grande ®t�1 15 require fire dampers. 2015 IBC o':\ Place.2019.03.pdf µ ° ,, d o ., Subject: PlanCheck 717.5.3 o -- o __ Author: nickt BB ,/ Color: ■ x i Page:o M2.03-MECHANICAL MIDDLE LEVEL PLAN �� ii Duct penetrations of the shaft ® 0 15 File Name: Plan Set.Mechanical.425 Rio Grande ao Place.2019.03.pdf require fire dampers. 2015 IBC 1 ® is. , Subject: PlanCheck 717.5.3 -) 0\ ,, Author: nickt Color: ■ ®%1 1 ' Hi= . __ Page: M2.04-MECHANICAL UPPER LEVEL PLAN ' I�li�reF4 I File Name: Plan Set.Mechanical.425 Rio Grande Duct penetrations of the shaft e� A l Alk -I Place.2019.03.pdf require fire dampers. 2015 IBC �'Fr; 1!� a 1 5 0 Subject: PlanCheck 717.5.3 '' Ili� .:.�®R ��'I , ,p� / Author: nickt BB/� ]V F11I,010 7 Color: ■ - tiamsgati 1 , �I 1 „._. 1 .-55-: Page: M2.04-MECHANICAL UPPER LEVEL PLAN Provide a commissioning plan in File Name: Plan Set.Mechanical.425 Rio Grande accordance with 2015 IECC Place.2019.03.pdf Subject: PlanCheck C408.2.1. Author: nickt Color: ■ Plan Set.Structure.425 Rio Grande Place.2019.03.pdf(3) Page: SO.1 -GENERAL NOTES File Name: Plan Set.Structure.425 Rio Grande The civic building is part of the Place.2019.03.pdf same building as the library and =0 Subject: PlanCheck parking garage.Total occupant  =  f load for A occupancies exceed Author: nickt 300 requiring a risk category of � R II Color: • III per 2015 IBC 1604.5. b d°g=d depe,l°,med°,la,m°d° Page: SO.3-GENERAL NOTES ed= o oJ9aee a'" o°ne,de, =wei11be`Peml File Name: Plan Set.Structure.425 Rio Grande Provide the statement of special inspections as required by the D11 Place.2019.03.pdf special inspection agreement Subject: PlanCheck Frgvide lhesWiemeni of ape=ia Author: nickt and 2015 IBC 1704.2.3. ✓Inspections as required by special+ ✓Inspection agreement and 2015 IBC+ • ✓1704.2.3. Color: o-t= Page: S2.14- MIDDLE LEVEL PARTIAL FRAMING PLAN AREA C Detail the firewall in the ' i � o= File Name: Plan Set.Structure.425 Rio Grande structurals and demonstrate how Place.2019.03.pdf it will allow either side to collapse without affecting the ALIBim" I u PlanCheck �a. Author: nickt wall. 2015 IBC 706.2 ti Color: ■ .si,a Special Inspection and Testing Agreement.425 Rio Grande Place.2019.03.pdf(1) 2. Enforce special Page: 3 1nspeciorshall " File Name: Special Inspection and Testing Agreement.425 Special inspection agreement addidnn t°1tiat, 0ve�"g°rssr"` Rio Grande Place.2019.03.pdf must be signed by special • Re“'""s"'i Subject: PlanCheck inspector, owner, and fabricator. Special inspection pr„grest and fin agreement must be Perform❑nain Author: nickt signed by special aPpevaitraPi Color: • inspector,owner,and wed and ap fabricator. Project Address: