Loading...
HomeMy WebLinkAboutFile Documents.427 Rio Grande Pl.0016.2019 (9).ACBK 0016-2019-ACBK_BuildingComments_7 COMcheck Envelope.425 Rio Grande Place.2020.03.04.pdf(2) Subject: PlanCheck Page: 7 Is this the channel glass? It Page Index: 7 should not be entered as a wood wall. Author: nickt Color: • ::— I -- File Name: COMcheck Envelope.425 Rio Grande EESE=^".7-2,."----",=====. Place.2020.03.04.pdf Subject: PlanCheck ___ Page: 7 Sign and date the comchecks. Page Index: 7 _s_r __ _ Author: nickt Color: ■ File Name: COMcheck Envelope.425 Rio Grande Place.2020.03.04.pdf Plan Set.Arch.425 Rio Grande Place.2020.03.04.pdf(8) u o Q Subject: PlanCheck q z Page:A0.8 COMCHECK ENVELOPE Detail 5/A9.3 shows a depth now ,.� w Page Index: 15 of 4". Update this sheet. ., r ; �;;.:^:a N Author: nickt ° Q Color: ■ 25 0G.08 File Name: Plan Set.Arch.425 Rio Grande oo Place.2020.03.04.pdf COMCHECK ENVELOPE 1 in--.X�ln j�� g ID Subject: PlanCheck ..r-. Page:A0.8 COMCHECK ENVELOPE What has so far been submitted �e §t IoIDd11 :ZIR r+ d-� is not sufficient to permit the Page Index: 15 ..- approval of the channel glass. �� jl L3-II it�II �� Author: nickt We will move forward with �— Color: ■ issuance of this core and shell File Name: Plan Set.Arch.425 Rio Grande q G �� Place.2020.03.04.pdf permit with a U factor of 0.30 for s of the channel glass with the J understanding that you will either EVEL FLOOR PLAN �I U❑ .".Ma provide sufficient documentation of the actual channel glass U-factor or will substitute for another product, either of which will be demonstrated to have a U-factor of 0.30 or less. Subject: PlanCheck Page:A0.8a COMCHECK EXHIBITS The floor and roof of this bay Page Index: 16 window bump out should be arp W°m� included in A0.8a and a;la Author: nickt Color: ■ Comcheck. t File Name: Plan Set.Arch.425 Rio Grande Place.2020.03.04.pdf Subject: PlanCheck Page:A0.8a COMCHECK EXHIBITS The trash vestibule is Page Index: 16 unconditioned space. It should Author: nickt be included in the exhibit on Color: • A0.8a as both roof and floor area File Name: Plan Set.Arch.425 Rio Grande which should also be entered in `' Comcheck. Is the trash area Place.2020.03.04.pdf -- inside the thermal envelope? If not, it should also be included. P7 I - . Subject: PlanCheck Page:A0.8a COMCHECK EXHIBITS The roof above the central stair F� � � Page Index: 16 is a different assembly than the .. Author: nickt rest of the upper level roof. It Color: • uses R-5/A9.1 which shows File Name: Plan Set.Arch.425 Rio Grande R 10 continuous and R 30 r«,_ cavity. Separately show it on —. ,—4 Place.2020.03.04.pdf A0.8a and enter it in Comcheck to match. d d Subject: PlanCheck ® ® . s.'' Page:A4.1 BUILDING SECTIONS This area is shown as Roof 1 on 4 4 A0.8a. On the Comcheck it is _ ; 4 Po Page Index: 41 Author: nickt shown has having R-40 Color: • continuous insulation. Is there a riiiI_�I�__ I detail of this'roof assembly File Name: Plan Set.Arch.425 Rio Grande ■� '=3 showing the insulation? It 4 �Ir�.1 . Ir Place.2020.03.04.pdf —ai 'g —_ appears that continuous ®® insulation would be impossible I - --- with the twin T concrete. Perhaps the Comcheck should show R-40 cavity insulation. Please provide a detail of this assembly with a call out to it and coordinate with the Comcheck. Subject: PlanCheck n ® Page:A4.1 BUILDING SECTIONS This area is shown as Floor 1 on 4 'r_=�II;•C RiErrzwiNGUN Page Index: 41 A0.8a. Please reference a detail ® `I --ems Author: nickt on A9.1 (guessing C-2?). On the e I -°'"-ii7ii "'- Color: • Comcheck it is shown as having R 40 cavityinsulation I'd like to ditty File Name: Plan Set.Arch.425 Rio Grande ® r �� verify this. ® 0 — Place.2020.03.04.pdf Subject: PlanCheck Page:A9.0j UL DESIGNS W12x40 columns are not listed Page Index: 72 in the UL X649 table. Provide Author: nickt W/D calculations to provide a Color: • required thickness of J File Name: Plan Set.Arch.425 Rio Grande intumescent coating to achieve Place.2020.03.04.pdf the required 1 hour fire rating. UL X649 states that the required thickness (T)for a 1 hour rating for an alternate sized column not found in the table with a W/D ratio ranging between 0.33 and 1.14 can be determined with the following equation: T=0.04785/(W/D) A W12x40 column has a W/D ratio of 0.734 per the following link: http://www.adfire.com/media/113 5/md-wd-table-j u ne-7-2007.pdf So T=0.04785/0.734=0.06519" Include this explanation and result on this sheet with UL X649.