Loading...
HomeMy WebLinkAboutFile Documents.210 W Main St.0056.2019 (7).ARBK0056-2019-ARBK_BuildingComments_4 Subject: PlanCheck Page: G.1.01 GENERAL INFORMATION Page Index: 1 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf Please resubmit full sets. There are too many sheets for us to swap out. DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf (17) Subject: Group Page: A.1.14B FIRE RATED ASSEMBLIES PLAN Page Index: 6 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf Exception 4 to 705.11 will be drastically easier to comply with. In order to separate the structures into individual buildings would require structurally independent 3 hr fire walls with no windows. Subject: PlanCheck Page: A.1.14B FIRE RATED ASSEMBLIES PLAN Page Index: 6 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf All of the roofs must be 1 hour fire rated to comply with the parapet exemption provisions of 2015 IBC 705.11 exception 4 (every exterior wall condition has beams running perpendicular to framing). Coordinate with your details. Subject: PlanCheck Page: A.1.14B FIRE RATED ASSEMBLIES PLAN Page Index: 6 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf Add a note to the plans stating that the mechanical room must be fire sprinklered and be sealed against the passage of smoke per 2015 IBC 509. The door must be self closing and weatherstripped to prevent smoke. No air transfer openings unless smoke dampers are used. Subject: PlanCheck Page: A.1.14B FIRE RATED ASSEMBLIES PLAN Page Index: 6 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf Add a note to the plans stating that the garbage room must be fire sprinklered and be sealed against the passage of smoke per 2015 IBC 509. KING LO 210 A Please resubmit full sets. There are too many sheets for us to swap out. W/D RG F DW W/DRG F DW DW DW 10 ' - 0 " UNIT 301 UNIT 302 10' LINE FROM STAIR 10' LINE FROM STAIR 1 8A.6.02A 9 A.6 . 0 2 A 7 A.6 . 0 2 A UNIT 101 STORAGE GARBAGE STORAGE WALL 8126 + 1/2" PLY he manufacturer for more detailed information on proprietary products. 30 GENERIC 1 HOURFIRE 45 to 49 STCSOUND Thickness: 57/8"Approx. Weight: 8 psfFire Test: OSU T-3054, 4-3-65Sound Test: OR 64-73, 9-23-64 OARD, WOOD FIBERBOARD, WOOD STUDS d, 0.82 psf, applied parallel to each side of 2 x 4 wood studss, 17/8" long, 0.0915" shank, 1/4" heads, 24" o.c. at verticals and 16" o.c. at top and bottom plates. Facelayer 5/8" typesum veneer base applied parallel to each side with 6" widelaminating adhesive along the perimeter and centerline ofails, 21/2" long, 0.131" shank, 9/32" heads, 12" o.c. to top andertical joints, and at third-points at intermediate studs. r and side. (LOAD-BEARING) 40 PROPRIETARY*1 HOUR FIRE 45 to 49 STC SOUND Thickness: 51/8"Approx. Weight: 8 psfFire Test: UL R2717-52, 9-9-68,UL Design U312;ULC Design W300Sound Test: G&H BW-27FT, 7-13-67 UM WALLBOARD, WOOD STUDS sum wallboard applied parallel to each side of 2 x 4 woodd nails, 11/2" long, 0.099" shank, 1/4" heads, 12" o.c. Jointsdes. Facelayer 1/2" proprietary type X plain or predecoratedm veneer base applied parallel to each side with 1/2" beadscoated nails, 17/8" long, 0.0915" shank, 1/4" heads, 6" o.c. atJoints offset 24" from base layer joints. (LOAD-BEARING) OPRIETARY GYPSUM BOARD-1/2" FireBloc® Type C-1/4" ToughRock® Sound Deadening Board-1/2" ToughRock® Fireguard® C-1/4" Soundcheck®-1/2" Firecheck® Type C-1/2" Gold Bond® Brand FIRE-SHIELD CTM Gypsum Wallboard Corporation -1/4" Temple-4 Sound Deadening Board-1/2" TG-C SCALE: 3/32" = 1'-0"4 SECTION 1-FIRE ASSEMBLY R FIRE RATED EXTERIOR WALL (WOOD SIDING) 1HR FIRE RATED EXTERIOR WALL (WOOD SIDING) FOR STRUCTURAL SHEAR Exception 4 to 705.11 will be drastically easier to comply with. In order to separate the structures into individual buildings would require structurally independent 3 hr fire walls with no windows. Subject: PlanCheck Page Index: 43 Page Label: A.6.02 ARCHITECTURAL DETAILS Author: nickt File Name: King Louise-Comments 1_Architectural Plans 072519.pdf Parapet exception #2 does notapply as all of the buildings areconsidered as a single "building"for building code purposes (2015503.1.2) and each floor exceeds1000 sqft. Considering them asseparate buildings would requirea fire wall (706) to separatethem. 2424 TOP OF PLY 2424 - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING (OR 5/8" DENSEGLASS@ 1HR FIRE WALL LOCATIONS)- 2x4@16 W/ 3 1/4" FOAM INSUL. (R22)- 6 mil VB- 5/8" GWB- 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- 5 1/2" SOUND BATT- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWB R19 INSUL CONT. 1x4 POPLAR BASE 28 - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING- 2x4@16 W/ 3 1/4" FOAM INSUL. (R22)- 6 mil VB- 5/8" GWB- 1 1/2 CONC TOPPING- VB- 3/4" PLY (GLUE & NAIL)- STEEL BEAM (SEE SCHEDULE)- 1/2" RESILIENT CHANNEL- 2 LAYERS TYP C 1/2" GWB R19 INSUL1/2" RS CEDAR PLYW 16 x 31 STL BMBATT INSULBATT INSUL CONT. 1x4 POPLAR BASE 2424 TOP OF PLY 28 SIDING TO TERMINATEAT UNDERSIDE OFCEILING DRYWALL. 2424 TOP OF PLY 2424 - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING- 2x4@16 W/ 3 1/4"FOAM INSUL. (R19)- 6 mil VB- 5/8" GWBEXT.TRASH - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- R 38 BATT INSUL.- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWB(SEE GA FILE NO. FC 5600 INSHEET A.6.02A) - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 6 mil. VB- 11 7/8 TJI @ 16 OC- R 38 BATT INSUL.- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWBCONTINUOUS VBSTANDARD TRUSS BLOCKINGCONT. 1x4 POPLAR BASE (TYP) -----@--- - ------ ----- GRAVEL STOP 1'-6" 24 GACOLOREDFLASHING W C 2424 2424 2424 TOP OF PLY - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING- 2x4@16 W/ 3 1/4" FOAM INSUL. (R22)- 6 mil VB- 5/8" GWB 24 GACOLOREDFLASHING - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- 1/2" DUROCK- 1/2" RS CEDAR PLY SEE ARCH R21 INSUL 11 7/8" RIM JOIST CONT. 1x4 POPLAR BASE (HYDROTECH GREEN ROOF SYSTEM-CLASS A.SEE SPEC. AND CERTIFICAITON ON A.6.09)) - 3" GREEN ROOF MATERIAL- TAPERED ROOF INSUL- 3/4" PLY- 11 7/8 TJI @ 16 OC W/ - 5" FOAM - BATT INSUL (R19)- VB- 5/8" GWB 1'-6" - 22 ga. PF FLASHING- 1/2" PLY- 5/8" DENS DECK, ALONG NEIGHBORING(SETBACK) WALL AND BEHIND FASCIA-1/2" RS CEDAR PLY4 1/2"SETBACK TOP OF PLY 2424 26262826 PARAPET EXCEPTIONS PER 2015 IBC 705.11:- SOUTH BUILDINGS:EXCEPTION 2: THE BUILDING HAS AND AREA OF NOT MORE THAT 1,000 SQUARE FEET (93M2) ON ANY FLOOR)-NORTH BUILDING:EXCEPTION 4: ONE-HOUR FIRE-RESISTANCE RATED EXTERIOR WALL THAT TERMINATE AT THE UNDERSIDE OF THEROOF SHEATHING, DECK OR SLAB, PROVIDED: 4.1. WHERE THE ROOF/CEILING FRAMING ELEMENT ARE PARALLEL TO THE WALLS. 4.2. WHERE THE ROOF/CEILING FRAMING ELEMENTS ARE NOT PARALLEL TO THE WALL. 4.3. OPENINGS IN THE ROOF SHALL NOT BE LOCATED WITHIN 5 FEET OF THE 1-HOUR FIRE-RESISTANCE-RATED EXTERIOR WALL. 4.4. THE ENTIRE BUILDING SHALL BE PROVIDED WITH NOT LESS THAN A CLASS BE ROOF COVERING. - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- 5 1/2" SOUND BATT- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWB(LISTED ASSEMBLY:GA FILE NO. FC 5600,SEE SHEET A.6.02A)TOP OF PLY24242424 24242424 - 5/8" GWB- 1/2" RESILIENT CHANNEL- 2x4@16 W/ 3 1/2" SOUND BATT- 1" NON COMBUSTIBLE DRAFT STOP- 2x4@16 W/ 3 1/2" SOUND BATT- 1/2" RESILIENT CHANNEL- 5/8" GWB(LISTED ASSEMBLY:GA FILE NO. WP 3812, SEE SHEET A.6.02A) WALL ASSEMBLY AS ABOVE(LISTED ASSEMBLY:GA FILE NO. WP 3812, SEESHEET A.6.02A) CONT. 1x4 POPLAR BASE (TYP)CONTINUOUS FIRE WALLASSEMBLY TO CONTINUOUSFLOOR SHEATHING TOCREATE FIRE BARRIER CONTINUOUS FIRE CEILINGASSEMBLY TO CONTINUOUSWALL ASSEMBLY TOCREATE FIRE BARRIER - 3/4" - 11 7 - 5" - 6 - VB- 5/8" - 5/8"- 1/2"- 2x4@- 1" D- 2x4@- 1/2"- 5/8" (SEE GREEN ROOF SYS. SPEC) 24242424 SEAL BETWEEN DOUBLE PLATESSEAL BETWEEN PLATE AND SHEATHING SEAL BETWEENDOUBLE PLATES - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING- 2x4@16 W/ 3 1/4" FOAM INSUL. (R22)- 6 mil VB- 5/8" GWB 24 GA COLOREDFLASHING - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- 5 1/2" SOUND BATT- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWB CAULKBLOCKING- 3"- 3 1/2 CONC TOPPING- 3/4" PLY (GLUE & NAIL)- 9 1/4" LVL @ 16 OC- 1/2" SOFFIT 4 1/2" 1'-7" TRIM 4"x4" RAILMESH4" 4" STEEL TUBE @ RAILING1 1/2" x 1 1/2"R19 INSUL SETBACK1'-6"VARIANCEPOWDER-COATEDRAILING &MESH 2424 TOP OF PLY2122424 212 - 3"- 3 1/2 CONC TOPPING- DRAINAGE MAT- 3/4" PLY (GLUE & NAIL)- 9 1/4" LVL @ 16 OC- 1/2" DUROCK- 1/2" RS CEDAR PLY TRIM 4"x4" RAILMESH4" 4" STEEL TUBE @ RAILING1 1/2" x 1 1/2" POWDER-COATEDRAILING &MESH 3'-0" ? CONNECTION &SPACER?? 3 1/4"3"3" - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING (OR 5/8" DENSEGLASS@ 1HR FIRE WALL LOCATIONS)- 2x4@16 W/ 3 1/4" FOAM INSUL. (R22)- 6 mil VB- 5/8" GWB- 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- 1/2" RESILIENT CHANNEL- 2 LAYERS 1/2" TYP C GWB W16x31242426 242426 TOP OF PLY 2424 - 1x WD SIDING- #15 FELT- 1/2" OSB SHEAT- 1" RIGID ISOCY- 1/2" OSB SHEAT@ 1HR FIRE WAL- 2x4@16 W/ 3 1- 6 mil VB- 5/8" GWB- 1 1/2 CONC TO- 3/4" T&G PLY (G- 11 7/8 TJI @ 16- 5 1/2" SOUND - 1/2" DUROCK- 1 LAYER 1/2" RS 3 1/4" x 11 7/8" PERIMETER FLEXIB - 3" DECK SLAB- 3/4" T&G PLY (G- 9 1/4" LVL TJI @ - 5" FOAM IN - 5 1/2" R 19- 7/8" DUROCK- 1 LAYER 1/2" RS R19 INSUL 3/4" SCALE: 1" = 1'-0"13TYP EXT WALL @ ?SCALE: 1" = 1'-0"14TYP EXT WALL @ ?SCALE: 1" = 1'-0"15TYP EXT WALL @ TRASH STORAGE SCALE: 1" = 1'-0"16DETAIL @ ENTRY ROOF SCALE: 1" = 1'-0"17DETAIL @ PARKING SCALE: 1" = 1'-0"18DETAIL @ ROOF EDGE SCALE: 1" = 1'-0"19DETAIL @ PARTY WALL SCALE: 1" = 1'-0"20DETAIL PARTY WALL @ ROOF SCALE: 1" = 1'-0"21DETAIL @ ENCROACHMENT SCALE: 1" = 1'-0"22RAILING DETAIL SCALE: 1" = 1'-0"23TYP EXTERIOR WALL SCALE: 1" = 1'-0"24DETAIL @ DECK TO FLOOR Parapet exception #2does not apply as allof the buildings areconsidered as a single"building" for buildingcode purposes (2015503.1.2) and eachfloor exceeds 1000sqft. Considering themas separate buildingswould require a firewall (706) to separatethem. - A.1.14B: Updated to have 1 hr. walls to separate buildings. - A.7.01: Updated corresponding windows. IN G L O U I S E H O U S I N G 21 0 W E S T M A I N S T R E E T AS P E N , C O 8 1 6 1 1 ALL DESIGNS, IDEAS ARRANGEMENTSAND PLANS INDICATED BY THESEDRAWINGS AND SPECIFICATIONS ARETHE PROPERTY AND COPYRIGHT OF KIMRAYMOND ARCHITECTS, INC. ANDSHALL NEITHER BE USED ON ANY OTHERWORK NOR BE USED BY ANY OTHERPERSON FOR ANY USE WHATSOEVERWITHOUT WRITTEN PERMISSION.WRITTEN DIMENSIONS SHALL TAKEP R E C E D E N C E O V E R S C A L E DDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE . ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECTPRIOR TO COMMENCEMENT OF WORK. KIM R A Y M O N D A R C H I T E C T S , I N C . | 3 0 0 E . H Y M A N A V E N U E , S U I T E 1 0 0 | | w w w . k i m r a y m o n d a r c h i t e c t s . c o m | | 9 7 0 - 9 2 5 - 2 2 5 2 | W/DFDW W/DRG F DW DW 0'-0 " UNIT 302 10' LINE FROM STAIR 1 8 9A.6 . 0 2 A 7A.6 . 0 2 A UNIT 102UNIT 101 UNIT 102UNIT 202 UNIT 302 STORAGE GARBAGE STORAGE UNIT 201 UNIT 301 UNIT 202 UNIT 302 UNIT 101 MECHANICALROOM UNIT 203UNIT 102 UNIT 103UNIT 102 12345678910111213141516 RG F D F W W D DWDW RG 10 ' - 0 " 0'-0 " 10'-0" 10' LINE FROM STAIR 1 RG UNIT 102UNIT 101(TYPE B UNIT) ST-103 GARBAGE 8 9A.6 . 0 2 A 7A.6 . 0 2 A WALL 8126 + 1/2" PLY NUAL TC TC TC SCALE: 3/32" = 1'-0"4 SECTION 1-FIRE ASSEMBLY SCALE: 3/32" = 1'-0"5 SECTION 5-FIRE ASSEMBLY SCALE: 3/32" = 1'-0"6 SECTION 6-FIRE ASSEMBLY ) H ENCLOSURES) 1HR FIRE RATED EXTERIOR WALL(WOOD SIDING) FOR STRUCTURAL SHEAR All of the roofs must be1 hour fire rated to comply with the parapet exemptionprovisions of 2015 IBC 705.11 exception 4(every exterior wall condition has beams running perpendicularto framing). Coordinate with your details. DW 1 2 1 2 3 4 56789101112131415161718 8 A.6.02A 9 A. 6 . 0 2 A 7 5 SCALE: 3/32" = 1'-0"1 GROUND LEVEL-FIRE RATED ASSEMBLIES Add a note to the plans stating that the mechanical room must be fire sprinklered and be sealed against the passage of smoke per 2015 IBC 509. The door must be self closing and weatherstripped to prevent smoke. No air transfer openings unless smoke dampers are used. 1 7 A. 6 . 0 2 A UNIT 102 UNIT 102 12345678910111213141516 D F W W D DW RG 10 ' - 0 " 10 ' - 0 " 10'-0 10' LINE FROM STAIRUNIT 101 (TYPE B UNIT) ST-101 ST-103 GARBAGE 8 A.6.02A 9 A. 6 . 0 2 A 7 A. 6 . 0 2 A SCALE: 3/32" = 1'-0"6 SECTION 6-FIRE ASS Add a note to the plans stating that the garbage room must be fire sprinklered and be sealed against the passage of smoke per 2015 IBC 509. rietary products. ULC Design W300 st: G&H BW-27FT, 7-13-67 Exception 4 to 705.11 will be drastically easier to comply with. In order to separate the structures into individual buildings would require structurally independent 3 hr fire walls with no windows. Subject: PlanCheck Page Index: 43 Page Label: A.6.02 ARCHITECTURAL DETAILS Author: nickt File Name: King Louise-Comments 1_Architectural Plans 072519.pdf Parapet exception #2 does notapply as all of the buildings are considered as a single "building"for building code purposes (2015503.1.2) and each floor exceeds 1000 sqft. Considering them as separate buildings would requirea fire wall (706) to separatethem. 2424 TOP OF PLY 2424 - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING (OR 5/8" DENSEGLASS@ 1HR FIRE WALL LOCATIONS)- 2x4@16 W/ 3 1/4" FOAM INSUL. (R22)- 6 mil VB- 5/8" GWB - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- 5 1/2" SOUND BATT- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWB R19 INSUL CONT. 1x4 POPLAR BASE 2 8 - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING- 2x4@16 W/ 3 1/4" FOAM INSUL. (R22)- 6 mil VB- 5/8" GWB - 1 1/2 CONC TOPPING- VB- 3/4" PLY (GLUE & NAIL)- STEEL BEAM (SEE SCHEDULE)- 1/2" RESILIENT CHANNEL- 2 LAYERS TYP C 1/2" GWB R19 INSUL 1/2" RS CEDAR PLYW 16 x 31 STL BM BATT INSUL BATT INSUL CONT. 1x4 POPLAR BASE 2424 TOP OF PLY 2 8 SIDING TO TERMINATEAT UNDERSIDE OFCEILING DRYWALL. 2424 TOP OF PLY 2424 - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING- 2x4@16 W/ 3 1/4"FOAM INSUL. (R19)- 6 mil VB- 5/8" GWB EXT.TRASH - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- R 38 BATT INSUL.- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWB(SEE GA FILE NO. FC 5600 INSHEET A.6.02A) - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 6 mil. VB- 11 7/8 TJI @ 16 OC- R 38 BATT INSUL.- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWB CONTINUOUS VB STANDARD TRUSS BLOCKINGCONT. 1x4 POPLAR BASE (TYP) -----@--- - ------ ----- GRAVEL STOP 1'-6" 24 GACOLOREDFLASHING W C 2424 2424 2424 TOP OF PLY - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING- 2x4@16 W/ 3 1/4" FOAM INSUL. (R22)- 6 mil VB- 5/8" GWB 24 GACOLOREDFLASHING - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- 1/2" DUROCK- 1/2" RS CEDAR PLY SEE ARCH R21 INSUL 11 7/8" RIM JOIST CONT. 1x4 POPLAR BASE (HYDROTECH GREEN ROOF SYSTEM-CLASS A.SEE SPEC. AND CERTIFICAITON ON A.6.09)) - 3" GREEN ROOF MATERIAL- TAPERED ROOF INSUL- 3/4" PLY- 11 7/8 TJI @ 16 OC W/ - 5" FOAM - BATT INSUL (R19)- VB- 5/8" GWB 1'-6" - 22 ga. PF FLASHING- 1/2" PLY- 5/8" DENS DECK, ALONG NEIGHBORING(SETBACK) WALL AND BEHIND FASCIA-1/2" RS CEDAR PLY 4 1/2"SETBACK TOP OF PLY 2424 26262826 PARAPET EXCEPTIONS PER 2015 IBC 705.11:- SOUTH BUILDINGS:EXCEPTION 2: THE BUILDING HAS AND AREA OF NOT MORE THAT 1,000 SQUARE FEET (93M2) ON ANY FLOOR)-NORTH BUILDING:EXCEPTION 4: ONE-HOUR FIRE-RESISTANCE RATED EXTERIOR WALL THAT TERMINATE AT THE UNDERSIDE OF THEROOF SHEATHING, DECK OR SLAB, PROVIDED: 4.1. WHERE THE ROOF/CEILING FRAMING ELEMENT ARE PARALLEL TO THE WALLS. 4.2. WHERE THE ROOF/CEILING FRAMING ELEMENTS ARE NOT PARALLEL TO THE WALL. 4.3. OPENINGS IN THE ROOF SHALL NOT BE LOCATED WITHIN 5 FEET OF THE 1-HOUR FIRE-RESISTANCE-RATED EXTERIOR WALL. 4.4. THE ENTIRE BUILDING SHALL BE PROVIDED WITH NOT LESS THAN A CLASS BE ROOF COVERING. - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- 5 1/2" SOUND BATT- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWB(LISTED ASSEMBLY:GA FILE NO. FC 5600,SEE SHEET A.6.02A)TOP OF PLY24242424 24242424 - 5/8" GWB- 1/2" RESILIENT CHANNEL- 2x4@16 W/ 3 1/2" SOUND BATT- 1" NON COMBUSTIBLE DRAFT STOP- 2x4@16 W/ 3 1/2" SOUND BATT- 1/2" RESILIENT CHANNEL- 5/8" GWB(LISTED ASSEMBLY:GA FILE NO. WP 3812, SEE SHEET A.6.02A) WALL ASSEMBLY AS ABOVE(LISTED ASSEMBLY:GA FILE NO. WP 3812, SEESHEET A.6.02A) CONT. 1x4 POPLAR BASE (TYP) CONTINUOUS FIRE WALLASSEMBLY TO CONTINUOUSFLOOR SHEATHING TOCREATE FIRE BARRIER CONTINUOUS FIRE CEILINGASSEMBLY TO CONTINUOUSWALL ASSEMBLY TOCREATE FIRE BARRIER - 3/4" - 11 7 - 5" - 6 - VB- 5/8" - 5/8"- 1/2"- 2x4@- 1" D- 2x4@- 1/2"- 5/8" (SEE GREEN ROOF SYS. SPEC) 24242424 SEAL BETWEEN DOUBLE PLATESSEAL BETWEEN PLATE AND SHEATHING SEAL BETWEENDOUBLE PLATES - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING- 2x4@16 W/ 3 1/4" FOAM INSUL. (R22)- 6 mil VB- 5/8" GWB 24 GA COLOREDFLASHING - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- 5 1/2" SOUND BATT- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWB CAULKBLOCKING - 3"- 3 1/2 CONC TOPPING- 3/4" PLY (GLUE & NAIL)- 9 1/4" LVL @ 16 OC- 1/2" SOFFIT 4 1/2" 1'-7" TRIM 4"x4" RAILMESH 4" 4" STEEL TUBE @ RAILING1 1/2" x 1 1/2" R19 INSUL SETBACK1'-6"VARIANCE POWDER-COATEDRAILING &MESH 2424 TOP OF PLY2 12 2424 2 12 - 3"- 3 1/2 CONC TOPPING- DRAINAGE MAT- 3/4" PLY (GLUE & NAIL)- 9 1/4" LVL @ 16 OC- 1/2" DUROCK- 1/2" RS CEDAR PLY TRIM 4"x4" RAILMESH 4" 4" STEEL TUBE @ RAILING1 1/2" x 1 1/2" POWDER-COATEDRAILING &MESH 3'-0" ? CONNECTION &SPACER?? 3 1/4" 3"3" - 1x WD SIDING- #15 FELT- 1/2" OSB SHEATHING- 1" RIGID ISOCYN. (R7)- 1/2" OSB SHEATHING (OR 5/8" DENSEGLASS@ 1HR FIRE WALL LOCATIONS)- 2x4@16 W/ 3 1/4" FOAM INSUL. (R22)- 6 mil VB- 5/8" GWB- 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- 1/2" RESILIENT CHANNEL- 2 LAYERS 1/2" TYP C GWB W16x31242426 242426 TOP OF PLY 2424 - 1x WD SIDING- #15 FELT- 1/2" OSB SHEAT- 1" RIGID ISOCY- 1/2" OSB SHEAT@ 1HR FIRE WAL- 2x4@16 W/ 3 1- 6 mil VB- 5/8" GWB - 1 1/2 CONC TO- 3/4" T&G PLY (G- 11 7/8 TJI @ 16- 5 1/2" SOUND - 1/2" DUROCK- 1 LAYER 1/2" RS 3 1/4" x 11 7/8" PERIMETER FLEXIB - 3" DECK SLAB- 3/4" T&G PLY (G- 9 1/4" LVL TJI @ - 5" FOAM IN - 5 1/2" R 19- 7/8" DUROCK- 1 LAYER 1/2" RS R19 INSUL 3/4" SCALE: 1" = 1'-0"13TYP EXT WALL @ ?SCALE: 1" = 1'-0"14TYP EXT WALL @ ?SCALE: 1" = 1'-0"15TYP EXT WALL @ TRASH STORAGE SCALE: 1" = 1'-0"16DETAIL @ ENTRY ROOF SCALE: 1" = 1'-0"17DETAIL @ PARKING SCALE: 1" = 1'-0"18DETAIL @ ROOF EDGE SCALE: 1" = 1'-0"19DETAIL @ PARTY WALL SCALE: 1" = 1'-0"20DETAIL PARTY WALL @ ROOF SCALE: 1" = 1'-0"21DETAIL @ ENCROACHMENT SCALE: 1" = 1'-0"22RAILING DETAIL SCALE: 1" = 1'-0"23TYP EXTERIOR WALL SCALE: 1" = 1'-0"24DETAIL @ DECK TO FLOOR Parapet exception #2does not apply as allof the buildings areconsidered as a single"building" for buildingcode purposes (2015503.1.2) and eachfloor exceeds 1000sqft. Considering themas separate buildingswould require a firewall (706) to separatethem. - A.1.14B: Updated to have 1 hr. walls to separate buildings. - A.7.01: Updated corresponding windows. Subject: PlanCheck Page: A.1.15 EGRESS PLAN Page Index: 7 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf The exterior stair is now an exit, so there is no need to measure travel distance down it. Instead, you need to measure travel distance from the furthest point in a unit to the stair. Subject: PlanCheck Page: A.1.15 EGRESS PLAN Page Index: 7 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf For the egress from the basement, start the travel path from the furthest point inside the basement (probably the mechanical room), to the stairs (which we can call an exit enclosure per 2015 IBC 1023). Subject: PlanCheck Page: A.6.02 ARCHITECTURAL DETAILS Page Index: 12 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf 2015 IBC 705.11 exception 4 requires the roof to be 1 hour fire rated across the entire span due to the beams running perpendicular to the exterior wall. Subject: PlanCheck Page: A.6.02A ARCHITECTURAL DETAILS Page Index: 13 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf Beams that require fire rating and support more than two floors or more than a floor and a roof must be individually encased in fire protection. Wrap the bottom of the beams in drywall. 2015 IBC 704.3 Subject: PlanCheck Page: A.6.02A ARCHITECTURAL DETAILS Page Index: 13 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf The 1 hour fire barriers must run continuously to the underside of the floor sheathing above (2015 IBC 707.5). The interior gypsum must be continuous to the underside of the floor sheathing. See structural detail 39/S3.4 which gets it right. Scale: AS NOTED ISSUESCHEMATIC DESIGN PERMIT SUBMITTAL COMMENTS 1 COMMENTS 2 KI N G L O U I S E H O U S I N G 21 0 W E S T M A I N S T R E E T AS P E N , C O 8 1 6 1 1 1" ACTUALIF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILLHAVE BEEN ENLARGED ORREDUCED, AFFECTING ALLLABELED SCALES. ALL DESIGNS, IDEAS ARRANGEMENTSAND PLANS INDICATED BY THESEDRAWINGS AND SPECIFICATIONS ARETHE PROPERTY AND COPYRIGHT OF KIMRAYMOND ARCHITECTS, INC. ANDSHALL NEITHER BE USED ON ANY OTHERWORK NOR BE USED BY ANY OTHERPERSON FOR ANY USE WHATSOEVERWITHOUT WRITTEN PERMISSION.WRITTEN DIMENSIONS SHALL TAKEP R E C E D E N C E O V E R S C A L E DDIMENSIONS AND SHALL BE VERIFIED ATTHE SITE . ANY DIMENSIONALDISCREPANCY SHALL BE BROUGHT TOTHE ATTENTION OF THE ARCHITECTPRIOR TO COMMENCEMENT OF WORK. A.1.15 9/17/19 EGRESSPLAN DATE11/22/18 KIM R A Y M O N D A R C H I T E C T S , I N C . | 3 0 0 E . H Y M A N A V E N U E , S U I T E 1 0 0 | | w w w . k i m r a y m o n d a r c h i t e c t s . c o m | | 9 7 0 - 9 2 5 - 2 2 5 2 | 03/05/19 07/01/19 09/16/19 W/D RG F DW W/DRG F DW DW DW 2A.1.153A.1.1 5 1A.1.15 EXIT POINT(EGRESS DISTANCEBEGINS) F 2 6 A 3 5 B C D G E 41 UNIT 301 UNIT 302 12345678910111213141516 W/D RG F W/D RG F DW RG F DW W/D W/D DWDW DW 2A.1.153A.1.1 5 1A.1.1 5 2'-0" 3'-7 1 / 2 " 17'-9"3'-7 1 / 2 " 2'-0" 16'-3 1 / 2 " FRO M T H I R D L E V E L F 2 6 A 3 5 B C D G E 41 UNIT 203 UNIT 102 UNIT 201 UNIT 202 12345678910111213141516 N RG F F D F W W D DW DWDW RG 2'-0" 3'-1 1 / 2 " 1'-9 1/4" 16'-3 1/ 2 " (FRO M S E C O N D L E V E L ) 2A.1.153A.1.1 5 1A.1.15 F 2 6 A 3 5 B C D G E 41 RG UNIT 102 UNIT 103(TYPE B UNIT) UNIT 101(TYPE B UNIT) ST-101 ST-103 GARBAGE(SPRINKLED) 10'-0"16'-10 1/4" (1 HR. WALLS + 45 MINDOORSAND WINDOWS)(1 HR. WALLS +60 MIN DOORSAND WINDOWS) UNIT202 UNIT302 10'-0"3'-6"10'-0" (1 HR. WALLS + 45 MINDOORSAND WINDOWS) (1 HR. WALLS+60 MIN DOORSAND WINDOWS) (1 HR. WALLS + 45 MINDOORSAND WINDOWS) UNIT103 UNIT203 14'-7 1 / 4 " (TO GR O U N D L E V E L ) 3'-4 1/4" (TO LAND I N G ) 2A.1.153A.1.1 5 1A.1.15 123 4 56789101112131415161718 F 2 6 A 3 5 B C D G E 41 2'-11" 3'-1 1 1 / 2 " MECHANICAL ST-101 ST-201ST-202 ST-203 ST-301 ST-302 ST-102 ST-103 COMMON STORAGE SCALE: 3/32" = 1'-0"3 EGRESS PLAN - THIRD LEVEL SCALE: 3/32" = 1'-0"2 EGRESS PLAN - SECOND LEVEL SCALE: 3/32" = 1'-0"1 EGRESS PLAN - GROUND LEVEL SCALE: 1/8" = 1'-0"ST2 STAIR ELEVATION 2 SCALE: 1/8" = 1'-0"ST3 STAIR ELEVATION 3 SCALE: 3/32" = 1'-0"1 EGRESS PLAN - LOWER LEVEL OOR - 3 1/2" - 0" - 3 1/2"- 11 1/4"6 1/2" GRESS IS GREATER ARE MAKINGHR RATED. SEE OOR - 10" . - 10" The exterior stair isnow an exit, so thereis no need to measuretravel distance downit. Instead, you need to measure traveldistance from thefurthest point in a unitto the stair. F G E N F A B C D G E 1 14'-7 1 / 4 " (TO G R O U N D L E V E L ) 3'-4 1/4 " (TO LA N D I N G ) 2A.1.15 3 A.1 . 1 5 1A.1 . 1 5 1 2 3 4 56789101112131415161718 F 2 6 A 3 5 B C D G E 41 2'-11" 3'- 1 1 1 / 2 " MECHANICAL ST-101 ST-201ST-202 ST-203 ST-301 ST-302 ST-102 ST-103 COMMON STORAGE SCALE: 3/32" = 1'-0"2 EGRESS PLAN - SECON SCALE: 3/32" = 1'-0"1 EGRESS PLAN - GROU SCALE: 3/32" = 1'-0"1 EGRESS PLAN - LOWER LEVEL For the egress from the basement, start the travel path from the furthest point inside the basement (probably the mechanical room), to the stairs (which we can call an exit enclosure per 2015 IBC 1023). TOP OF PLY TYPICAL EXTERIOR WALL - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- 1/2" DUROCK- 1/2" RS CEDAR PLY R21 INSUL 11 7/8" RIM JOIST CONT. 1x4 POPLAR BASE RIM BOARD (HYDROTECH GREEN ROOF SYSTEM-CLASS A. SEE SPEC. AND CERTIFICAITON ON A.6.09) - 3" GREEN ROOF MATERIAL- TAPERED ROOF INSUL- 3/4" PLY- 11 7/8 TJI @ 16 OC W/ - 5" FOAM - BATT INSUL (R19)- VB- 5/8" GWB 1'-6" - 22 ga. PF FLASHING- 1/2" PLY- 2 LAYERS 5/8" DENS DECK, ALONGNEIGHBORING(SETBACK) WALL AND BEHIND FASCIA-1/2" RS CEDAR PLY 4 1/2" SETBACK TOP OF PLY 2 4 2 6 2 6 2 8 2 6 PARAPET EXCEPTIONS PER 2015 IBC 705.11:- SOUTH BUILDINGS:EXCEPTION 2: THE BUILDING HAS AND AREA OF NOT MORE THAT 1,000 SQUARE FEET (93M2) ON ANY FLOOR) -NORTH BUILDING:EXCEPTION 4: ONE-HOUR FIRE-RESISTANCE RATED EXTERIOR WALL THAT TERMINATE AT THE UNDERSIDE OF THEROOF SHEATHING, DECK OR SLAB, PROVIDED: 4.2. WHERE THE ROOF/CEILING FRAMING ELEMENTS ARE NOT PARALLEL TO THE WALL. 4.3. OPENINGS IN THE ROOF SHALL NOT BE LOCATED WITHIN 5 FEET OF THE 1-HOUR FIRE-RESISTANCE-RATED EXTERIOR WALL. 4.4. THE ENTIRE BUILDING SHALL BE PROVIDED WITH NOT LESS THAN A CLASS BE ROOF COVERING. 2 4 TYPICAL 1 HR. FIRE RATEDWALL (REFERENCEASSEMBLY PLAN A.1.14BFOR LISTED ASSEMBLY) SEAL BETWEEN DOUBLE PLATES SEAL BETWEEN PLATE AND SHEATHING TYPICAL EXTERIOR WALL - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL) - 3"- 3 1/2 CONC TOPPING- DRAINAGE MAT 4" POWDER-COATEDRAILING &MESH 3'- 0 " L @ UPPER FLOORS SCALE: 1" = 1'-0"14 TYP. EXTERIOR WALL @ PARKING OVERHANG SCALE: 1" = 1'-0 15 TYP EXT W OVERHANG SCALE: 1" = 1'-0"18 DETAIL @ ROOF EDGE (FRAMING NOT PARALLEL TO WALL) SCALE: 19 DET 2015 IBC 705.11 exception 4 requires the roof to be 1 hour fire rated across the entire span due to the beams running perpendicular to the exterior wall. MBLY: 115 WA FC 2 6 26 2 4 Beams that require fire rating and support more than two floors or more than a floor and a roof must be individually encased in fire protection. Wrap the bottom of the beams in drywall. 2015 IBC 704.3 TYP. 1H EXTERIOR WALLFIRE ASSEMBLY.SEE ASSEMBLY @ A1.14B DRYWALL SEALEDTO SECOND PLATE DRYWALL SEALED TO TOP PLATE RIM JOIST SEALED TO TOP PLATE SPRAY FOAM RIM JOIST CLOSURE EXTEND SHEATHING PAST PLATE AND SEALTO FOUNDATION TYP. 1H EXTERIOR WALLFIRE ASSEMBLY.SEE ASSEMBLY@ A1.14B 1H EXTERIORFIRE ASSEMBLY.SEE ASSEMBLY @ A1.14B WALKWAY EXTERIOR INTERIORINTERIOR EXTERIOR INTERIORINTERIOR T.O. F.F. @SECOND LEVEL 109'-4" The 1 hour fire barriers must run continuously to the underside of the floor sheathing above (2015 IBC 707.5). The interior gypsum must be continuous to the underside of the floor sheathing. See structural detail 39/S3.4 which gets it right. Subject: PlanCheck Page: A.6.03 STAIR DETAIL: EXTERIOR Page Index: 14 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf Handrails are required on both sides of all exterior stairs and extensions are required to project in the same direction as the stair flight for 12" horizontally at the top and sloped for the depth of one tread at the bottom (except when continuous between flights). Revise stair plans and details. 2015 IBC 1011.11, 1014.6. Subject: PlanCheck Page: A.6.06 ADA BATHROOM DETAILS Page Index: 17 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf Clear space must be centered on the lavatory. ICC/A117.1 ection 1004.11.3.1.1 Subject: PlanCheck Page: A.6.06 ADA BATHROOM DETAILS Page Index: 17 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf The dimensions you have given for blocking are the required dimensions for the grab bars. Blocking will need to be slightly bigger to allow for solid attachment of grab bars in the future. Subject: PlanCheck Page: A.6.06 ADA BATHROOM DETAILS Page Index: 17 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf Water closet only requires 48" clearance in type B bathrooms. ICC/A117.1-2009 section 1004.11.3.1.2 Subject: PlanCheck Page: A.6.06 ADA BATHROOM DETAILS Page Index: 17 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf 24" minimum required from lavatory centerline to side wall face of finishe. I recommend you provide some leeway to avoid needing to revise at final inspection. ICC/A117.1-2009 section 1004.11.3.1.1 LEVEL Handrails are required on both sides of all exterior stairs and extensions are required to project in the same direction as the stair flight for 12" horizontally at the top and sloped for the depth of one tread at the bottom (except when continuous between flights). Revise stair plans and details. 2015 IBC 1011.11, 1014.6. 11'-3" 1'-4" MA X . MA X . 2'-0"4"MAX.1'-0"2'-0"3'-0" MIN. 2'- 6 " 3'-8" 2'- 0 " 2'-6" 4'-0" 2'- 6 " 4'- 0 " 2'-6" 2'-0"4"MAX. 32" CLEARANCE 1'-3"2'-9" 5'-0" 4'- 8 " 2'-0" APPROACH. HEIGHT 34" ADA CABINET FOR PARALLEL BLOCKING ON WALL (FOR FUTURE GRAB BAR INSTALLATION ) FLOOR CLEARANCE 2 4 1 3 ELEVATION 1 FLOOR PLAN (BATH 2 - ADA TYPE B) KEY: FLOOR CLEARANCE(30"x48" OUTSIDE OF DOORSWING) TILE FLOOR DIMENSION NOTES: * ALL DIMENSIONS ARE REQUIRED FROM FINISHED SURFACES. * NOTES: * LAVATORY HEIGHT TO BE 34" IN THIS BATHROOM. Clear space must be centered on the lavatory. ICC/A117.1 ection 1004.11.3.1.1 ISSUE SCHEMATIC DESIGN PERMIT SUBMITTAL COMMENTS 1 COMMENTS 2 KI N G L O U I S E H O U S 21 0 W E S T M A I N S T R E E T AS P E N , C O 8 1 6 1 1 DATE 11/22/18 03/05/19 07/01/19 09/16/19 3" - 6 " 1'- 6 " 4"MAX 18 " M I N . 4'-6" MIN. KOHLERCHOREOGRAPH SHOWER PANEL: WHITE SHOWER CURTAIN ROD BLOCKING FOR GRAB BAR The dimensions you have given for blocking are the required dimensions for the grab bars. Blocking will need to be slightly bigger to allow for solid attachment of grab bars in the future. 1'-4" 1'- 3 " MA X . 4'- 0 " MA X . 2'- 6 " 2'-6" 5'- 9 3 / 4 " 2'- 6 " 4'- 0 " 2'-6" 2'-0"4"MAX. 32" CLEARANCE 1'-3" 5'-0" 4'- 8 " ADA CABINETFOR PARALLELAPPROACH BLOCKING ON WALL(FOR FUTURE GRAB BARINSTALLATION ) FLOOR CLEARANCE 2 4 1 3 ELEVATION ELEVATION FLOOR PLAN (BATH 2 - ADA TYPE B) KEY: FLOOR CLEARANCE(30"x48" OUTSIDE OF DOORSWING) TILE FLOOR DIMENSION NOTES: * ALL DIMENSIONS ARE REQUIREDFROM FINISHED SURFACES. * NOTES: * LAVATORY HEIGHT TO BE 34"IN THIS BATHROOM. Water closet only requires 48" clearance in type B bathrooms. ICC/A117.1-2009 section 1004.11.3.1.2 Scale: AS ISSUE SCHEM PERMIT COMM COMM KI N G L O U I S E H O U S I N G 21 0 W E S T M A I N S T R E E T 1" ACT IF THE ABOVE DIM NOT MEASURE O EXACTLY, THIS D HAVE BEEN EN REDUCED, AFF LABELED S ALL DESIGNS, IDEAS AND PLANS INDIC DRAWINGS AND SPE THE PROPERTY AND C RAYMOND ARCHITE SHALL NEITHER BE USE WORK NOR BE USED PERSON FOR ANY U WITHOUT WRITTEN WRITTEN DIMENSIO P R E C E D E N C E O DIMENSIONS AND SHA THE SITE . ANY DISCREPANCY SHALL THE ATTENTION OF PRIOR TO COMMENCE AD BATHRO DETA DATE 11/22/18 KIM R A Y M O N D A R C H I T E C T S , I N C . 03/05/19 07/01/19 09/16/19 11'-3" 1'-4" 1'-3 " MAX . 4'-0 " MAX . 2'-0"4"MAX.1'-0"2'-0"3'-0" MIN. 2'-6 " 3'-8" 2'-0 " 2'-6" 5'-9 3 / 4 " 34" - 3 6 " 33 " - 3 6 " 4'-0" 2'-6 " 4'-0 " 2'-6" 33" - 3 6 " 3"-6 " 1'-6 "MIN . 2'-0"4"MAX. 32" CLEARANCE 2'-8" 1'-4"1'-3"2'-9" 33"- 3 6 " 3"-6 " 1'-6 " MIN . 2'-2" 5'-0" 4'-8 " 2'-1 0 " 2'-1 0 " 2'-3 " 9" 2'-0" 2'-0" ADA CABINETPARELLELAPPROACH. HEIGHT 34" ADA CABINETPARALLELAPPROACH ADA CABINETFOR PARALLELAPPROACH BLOCKING ON WALL(FOR FUTURE GRAB BARINSTALLATION )FLOOR CLEARANCE 2 4 1 3 ELEVATION 1 ELEVATION 2 ELEVATION 3 ELEVATION 4 FLOOR PLAN(BATH 2 - ADA TYPE B) KEY: FLOOR CLEARANCE(30"x48" OUTSIDE OF DOORSWING) TILE FLOOR DIMENSION NOTES: * ALL DIMENSIONS ARE REQUIREDFROM FINISHED SURFACES. * NOTES:* LAVATORY HEIGHT TO BE 34"IN THIS BATHROOM. 8'-0 1 / 4 " 1'-6" 4'-3 3/4"(48" MIN.) 3'-0 " 1'-6" 1'-10"1'-2" 4'-0" 2'-6 " 2'-0 " 3'-6" 3'-0 1 / 4 " 2'-0" 3'-6" 2'-0" 34"- 3 6 " 34" - 3 6 " 34" - 3 6 " 4'-8 " 4'-0" 2'-10"DOOR CLEARANCE 3'-0" 3'-0" 4'-3 3/4" 2'-1 0 " AD A 2'-1 0 " AD A 34"- 3 6 " 3"-6 " 1'-6 " 4"MAX 39"-41" 34"- 3 6 " 39"- 4 1 " 18" M I N . 4'-6" MIN. 3'-7 1/4" PERPENDICULARSHOWERAPPROACH KOHLERCHOREOGRAPH SHOWERPANEL: WHITE SHOWERCURTAINROD KOHLERCHOREOGRAPH SHOWERPANEL: WHITE SHOWERCURTAIN ROD KOHLERCHOREOGRAPHSHOWERPANEL: WHITE SHOWERCURTAINROD VANITY MAXIMUMHEIGHT 34" BLOCKING FORGRAB BAR 2 4 1 3 ELEVATION 1 ELEVATION 2 ELEVATION 4ELEVATION 3 CL CL CL CL 30" X 48" BLOCKING ON WALL(FOR FUTURE GRAB BARINSTALLATION )FLOOR CLEARANCE FLOOR PLAN(BATH - ADA TYPE B) KEY: FLOOR CLEARANCE(30"x48" OUTSIDE OF DOORSWING) DIMENSION NOTES: * ALL DIMENSIONS ARE REQUIREDFROM FINISHED SURFACES. * 56" X 48" NOTES:* LAVATORY HEIGHT TO BE 34"IN THIS BATHROOM. Features•60"L x 30-1/4"W x 14"H•Our most popular bath•Integral apron for quick installation•Constructed KOHLER® Cast Iron•Designed for one-person bathingRecommended AccessoriesK-1491 Bath/Whirlpool PillowK-1601 Bath/Whirlpool FootstopK-7213 27" Cable Bath DrainK-7214 27" Cable Bath DrainK-702200-G54 Frameless Sliding Bath DoorK-702200-G73 Frameless Sliding Bath DoorK-702200-L Frameless Sliding Bath DoorK-702205-L Frameless Sliding Bath Door Codes/StandardsK-706000-D3 Frameless Sliding Bath Door ASME A112.19.1/CSA B45.2K-706000-L Frameless Sliding Bath Door ASTM F462K-706003-L Frameless Sliding Bath Door ADAK-706004-D3 Frameless Sliding Bath Door ICC/ANSI A117.1K-706004-L Frameless Sliding Bath DoorK-706007-L Frameless Sliding Bath DoorK-7160-TF Bath Drain KOHLER® Enameled Cast Iron Bathand Shower Base Lifetime LimitedWarrantySee website for detailed warranty information. Available Color/FinishesColor tiles intended for reference only.DescriptionCodeColorWhite0Biscuit96Almond47 1-800-4KOHLER (1-800-456-4537)Kohler Co. reserves the right to make revisions without notice to product specifications.For the most current Specification Sheet, go to www.kohler.com.12-4-2018 15:04 - US/CA/MX Villager®5' BathK-716 60" (1524 mm) NotesTechnical Information Measure your actual product for rough-in details.All product dimensions are nominal.Install this product according to the installationinstructions.3-Wall AlcoveInstallation:RightDrain location:The hot water supply should be 70% of thecapacity of the bath or greater. Installations willvary.45" x 22" (1143 mm x 559 mm)Basin area, bottom:55" x 24" (1397 mm x 610 mm)Basin area, top:316 lbs (143.3 kg)Weight:ADA compliant when installed to the specificrequirements of these regulations.49 lbs/ft² (239.2 kg/m²)Minimum floor load:8-5/8" (219 mm)Water depth:33 gal (124.9 L)Water capacity:2-1/2" (64 mm)Minimum flat for door: 1-800-4KOHLER (1-800-456-4537)Kohler Co. reserves the right to make revisions without notice to product specifications.For the most current Specification Sheet, go to www.kohler.com.12-4-2018 15:04 - US/CA/MX Villager®5' BathK-716 Submitted Model No.: Specific Features: Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation. Dimensions are for reference only. See current full-line price book or www.deltafaucet.com for finish options and product availability. Delta Faucet Company55 E. 111th Street, Indianapolis, IN 46280350 South Edgeware Road, St. Thomas, ON N5P 4L1© 2017 Delta Faucet CompanyDSP-L-B2510LF Rev. E LAVATORY FAUCET ■Two Handle Deck MountSTANDARD SPECIFICATIONS:• Maximum 1.2 gpm @ 60 psi, 4.5 L/min @ 414 kPa• Three hole mount• 1/4 turn handle stops• Hot and cold stems are interchangeable• Lever handle control mechanism is a rotating cylinder type with stainless steel plate and 90° rotating with replaceable non-metallic seatsWARRANTY:• Lifetime limited warranty on parts (other than electronic parts and batteries) and finishes: or, for commercial users, for 5 years from date of purchase.• 5 year limited warranty on electronic parts (other than batteries); or, for commercial users, for 1 year from the date of purchase. No warranty is provided on batteries. Certified byCSA Group COMPLIES WITH:• ASME A112.18.1 / CSA B125.1• ASME A112.18.2 / CSA B125.2 Indicates compliance to ICC/ANSI A117.1• EPA WaterSense®• Verified compliant with 0.25% weighted average Pb content regulations B2510LF▲B2510LF-PPU▲ ▲Designate proper finish suffix 1 7/8" (48 mm)2 1/2" (64 mm) 1 1/4" (32 mm) Max. Deck Thickness 4 5/16" (110 mm) Min. 2 1/2" (64 mm)Clearance to Back Splash Recommended 1/2"-14NPSM 4" (102 mm) 2x 1 1/8" to 1 1/2" (29 mm to 38 mm) hole size 3 3/4" (95 mm) 6" (152 mm) 2 1/4" (57 mm) 3 3/4" (95 mm) 45/8"(118mm) 31/2"(89mm) 21/8"(54mm)Dia. 11/4"(32mm)Dia. 13/8"(35mm)Dia. 15/8"(42mm)to23/8"(61mm) 2 1/8"(54 mm)Dia. 3 1/2"(89 mm) 4 7/8"(124 mm) 1 1/4"(32 mm)Dia. 1 5/8"(42 mm)to2 3/8"(61 mm) 7-5/16" NotesTechnical Information Install this product according to the installationinstructions.All product dimensions are nominal.Under-mountInstallation:Countertop manufacturer or cutter must use thecut-out template provided with the product, or aLength: 17-5/8" (448 mm)Width: 13-1/8" (334 mm)Bowl area:current one provided by Kohler Co. (callBowl depth: 5-5/16" (135 mm)Water depth: 3-5/8" (93 mm)1-800-43-FOCUS). Kohler Co. is not responsiblefor cut-out errors when the incorrect cut-outtemplate is used.1-3/4" (44 mm)Drain hole:1281904-7, not required, not includedTemplate:ADA compliant when installed to the specificrequirements of these regulations. 1-800-4KOHLER (1-800-456-4537)Kohler Co. reserves the right to make revisions without notice to product specifications.For the most current Specification Sheet, go to www.kohler.com.1-11-2019 10:56 - US/CA/MX Caxton® RectangleUnder-mount Bathroom SinkK-20000 Submitted Model No.: ____________________________________________Specific Features: _______________________________________________ BT13010▲BT13210▲BT13410▲ 7"(178 mm) 2 3/4"(70 mm) 2 3/8"(60 mm) 3 1/2"(89 mm) Face of plasterguard should be flush with finish wall line 8" (203 mm)min.18" (457 mm)max. TUB AND SHOWER FAUCET TRIM ■ Foundations® Bath Collection■ Valve Only (BT13010 Series)■ Shower Only (BT13210 Series)■ Tub/Shower (BT13410 Series) STANDARD SPECIFICATIONS• Maintains a balanced pressure of hot and cold water even when a valve is turned on or off elsewhere in the system.• For use with MultiChoice® Universal rough valve body. (R10000 Series)• Back-to-back installation capability.• Solid brass forged body.• Temperature only controlled with handle.• Field adjustable means to limit handle rotation into hot water zone.• 120° - maximum handle rotation.• All parts replaceable from the front of the valve.• 1/2" -14 threaded tub spout.• Stem extension kit RP77991 can be ordered to allow for an additional 1 3/4" wall thickness. RP77991 ships with chrome escutcheon screws. For special finishes also order RP12630 escutcheon screws in desired finish. 012345 0102030405060708090Pressure (PSI) Flow (U . S . G a l l o n s P e r M i n u t e ) 6 069138207276345414483552621 03.87.611.415.118.922.7 Pressure (kPa) Flow ( L i t e r s P e r M i n u t e ) 1.75 GPM Showerhead 7 26.5Tub Filler 30.334.189 COMPLIES WITH• ASME A112.18.1 / CSA B125.1• ASSE 1016 Indicates compliance toICC/ANSI A117.1 - Valve control only• EPA WaterSense® Delta reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation. Dimensions are for reference only. See current full-line price book or www.deltafaucet.com for finish options and product availability.DSP-B-BT13010 Rev. G 2"(51 mm) 2 7/8"(73 mm) RP44809▲ 1.75 Showerhead RP61357▲RP62149▲WARRANTY• Lifetime limited warranty on parts (other than electronic parts and batteries) and finishes: or, for commercial users, for 5 years from date of purchase.• 5 year limited warranty on electronic parts (other than batteries); or, for commercial users, for 1 year from the date of purchase. No warranty is provided on batteries. 2 15/32"(63 mm)2 15/32"(63 mm) 2 3/8"(60 mm) Full Spray C/L Supply Lines Supply 5 13/32"(137 mm) 5 1/4"(133 mm) ▲ Designate proper finish suffix FEATURES: • Monitor® 13 Series pressure balanced bath mixing valve trim RP77991 Available Extension Kit Delta Faucet Company55 E. 111th Street, Indianapolis, IN 46280350 South Edgeware Road, St. Thomas, ON N5P 4L1© 2017 Delta Faucet Company Turner Dual Flush ToiletC41908D▲® Technical InformationFixture configuration Two-piece, round front Water per flush 1.6 gpf (6.0 lpf) / 1.1 gpf (4.1 lpf)Passageway 2" (51 mm)Water area 10" X 8" (253 mm x 202 mm)Seat post hole centers 5 1/2" (140 mm)Included:Tank RP91467▲Tank Cover (Less Flush Button) RP91470▲Flush Button Assembly RP91469▲Mounting Hardware – Bowl to floor RP71146Mounting Hardware – Tank to bowl RP72471 Seat Assembly RP92085▲ STANDARD SPECIFICATIONS:• Vitreous China.• 27 1/2" (698 mm) in length, 18" (457mm) in width, 31 1/8" (790 mm) in height.• Round front bowl with chair height design (16 1/2" to top of the bowl).•12" (305 mm) rough-in.• Dual/High Eff iciency Toilet (HET) Flush System.• 3" f lush valve• 2" (51mm) fully glazed trapway.• SmartFit TM tank-to-bowl connection with tool for installation• Includes polished chrome trip lever.• Delta toilet kit includes the tank, bowl, toilet seat, mounting hardware, wax ring and SmartFit TM Multi-Tool. No additional tool required. WARRANTY• Chinaware parts warranted to original consumer purchaser.• 1 year warranty on mechanical components, f ill valve, f lush valve, f lush lever handle, and mounting bolts will apply.• The toilet seat & lid will have a 1 year warranty. Installation Notes• Install this product according to the installation guide.• This model complies with the American Disabilities Act (ADA) when installed per the requirements of the Accessibility Guidelines, Section 604 Water Closets, of the Act, which includes the installation of an open front seat (not included).• This model complies with CSA B651 when installed per Clause 4.3.6 of the standard. C41908D▲ ▲ Designate proper finish suffix COMPLIES WITH• ADA • ASME A112.19.2 / CSA B45.1• ASME A112.19.14• ASME A112.19.5• ICC / ANSI A117.1• EPA WaterSense® High Eficiency Toilet• CalGreen Delta Faucet Company55 E. 111th Street, Indianapolis, IN 46280350 South Edgeware Road, St. Thomas, Ontario Canada N5P 4L1 Round Front Bowl Submitted Model No.: Top down view Left view Front view Foot Print Specific Features: ▲ Designate proper finish suffix 1"(25mm) 5 1/2"(140 mm)C/L of Seat Post Holes Centers Clearance toBack WallRecommended 15/16"-14UNS-1Thread 16 1/2"(420 mm) 21"(533 mm) 14 3/8"(364 mm) 5 7/8" (149 mm) 5" (127 mm)Typical RangeFor Existing Supply3/8" NPT Supply C/L of Outlet 12"(305 mm) 5 5/8"-6 3/8"(142-163 mm)Mounting Hole 16 1/2"(419 mm) 31 1/8"(790 mm) 8"(204 mm) 8"(204 mm) 9 7/8"(250 mm) C41908D▲ 18"(457 mm) 27 1/2"(698 mm) 8 3/4"(223 mm) C/L of Outlet Turner Dual Flush ToiletC41908D▲® Submitted Model No.: Specific Features: LAVATORY FAUCET ■Two Handle Deck MountSTANDARD SPECIFICATIONS:• Maximum 1.2 gpm @ 60 psi, 4.5 L/min @ 414 kPa• Three hole mount• 1/4 turn handle stops• Hot and cold stems are interchangeable• Lever handle control mechanism is a rotating cylinder type with stainless steel plate and 90° rotating with replaceable non-metallic seats WARRANTY:• Lifetime limited warranty on parts (other than electronic parts and batteries) and finishes: or, for commercial users, for 5 years from date of purchase.• 5 year limited warranty on electronic parts (other than batteries); or, for commercial users, for 1 year from the date of purchase. No warranty is provided on batteries. Certified byCSA Group COMPLIES WITH:• ASME A112.18.1 / CSA B125.1• ASME A112.18.2 / CSA B125.2 Indicates compliance to ICC/ANSI A117.1• EPA WaterSense®• Verified compliant with 0.25% weighted average Pb content regulations B2510LF▲B2510LF-PPU▲ ▲Designate proper finish suffix 1 7/8" (48 mm)2 1/2" (64 mm)1 1/4" (32 mm) Max. Deck Thickness 4 5/16" (110 mm) Min. 2 1/2" (64 mm)Clearance to Back Splash Recommended 1/2"-14NPSM 4" (102 mm) 2x 1 1/8" to 1 1/2" (29 mm to 38 mm) hole size 3 3/4" (95 mm) 6" (152 mm) 2 1/4" (57 mm) 3 3/4" (95 mm) 45/8"(118mm) 31/2"(89mm) 21/8"(54mm)Dia. 11/4"(32mm)Dia. 13/8"(35mm)Dia. 15/8"(42mm)to23/8"(61mm) 2 1/8"(54 mm)Dia. 3 1/2"(89 mm) 4 7/8"(124 mm) 1 1/4"(32 mm)Dia. 1 5/8"(42 mm)to2 3/8"(61 mm) SCALE: 1/2" = 1'-0"1 UNIT 103-BATH 2 (TYPE B-OPTION B) UNIT 101-BATH (TYPE B-OPTION B) 2 BAT_ TUB KOHLER K-716 2 DELTA FAUCET_DSP-L-B2510LF Rev E 2 DELTA FOUNDATIONS MONITRO 13-SHOER 24" minimum required from lavatorycenterline to side wallface of finishe. Irecommend youprovide some leewayto avoid needing torevise at finalinspection.ICC/A117.1-2009section 1004.11.3.1.1 Subject: PlanCheck Page: A.6.06 ADA BATHROOM DETAILS Page Index: 17 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf The lavatory may extend into the water closet clear space if you'd like to make the lavatory larger. There must be at least 33" total clearance from the lavatory edge to the water closet's side wall. ICC/A117.1-2009 section 1004.11.3.1.2.2.4 Although not required explicitly, the intent of the code is to provide vanity counter top space equivalent to the non-accessible units. (ICC/A117.1-2009 section 1002.11.2.1) Subject: PlanCheck Page: A.6.13 ARCHITECTURAL DETAILS Page Index: 24 Author: nickt Color: File Name: DR 01. ARCHITECTURAL - 210 W. Main St. - Permit Comments 2 091719.pdf 2015 IBC 705.11 exception 4 requires the roof to be 1 hour fire rated across the entire span due to the beams running perpendicular to the exterior wall. Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: DR 04. MECHANICAL - 9001_MP-revised_08-26-19_stamped-signed.pdf Openings within 10' of the exterior exit stair require 3/4 hour fire protection (dampers). 2015 IBC 1027.6 DR 04. MECHANICAL - 9001_MP-revised_08-26-19_stamped-signed.pdf (7) Subject: PlanCheck Page: 2 Page Index: 2 Author: nickt Color: File Name: DR 04. MECHANICAL - 9001_MP-revised_08-26-19_stamped-signed.pdf Mechanical intake and exhaust must be 10' apart. 2015 IMC 401.4 item 2. 8'- 0 1 / 4 " 1'-6" 3 1'-6" 1'-10"1'-2" 4'-0" 2'- 6 " 2'- 0 " 3'-6" 3'- 0 1 / 4 " 2'-0" 3'-6" 2'-0" 34 " - 3 6 " 34 " - 3 6 " 4'- 8 " 4'-0" 4'-3 3/4" 2'- 1 0 " AD A 3'-7 1/4" PERPENDICULARSHOWER APPROACH SHO CU RO VANITY MAXIMUMHEIGHT 34" 2 4 1 3 ELEVATION 1 ELEVATION 3 CL 30" X 48" BLOCKING ON WALL(FOR FUTURE GRAB BARINSTALLATION ) FLOOR CLEARANCE FLOOR PLAN(BATH - ADA TYPE B) KEY: FLOOR CLEARANCE(30"x48" OUTSIDE OF DOORSWING) DIMENSION NOTES: * ALL DIMENSIONS ARE REQUIRED FROM FINISHED SURFACES. * 56" X 48" NOTES: * LAVATORY HEIGHT TO BE 34"IN THIS BATHROOM. UNIT 101-BATH (TYPE B-OPTION B) The lavatory may extend into the water closet clear space if you'd like to make the lavatory larger. There must be at least 33" total clearance from the lavatory edge to the water closet's side wall. ICC/A117.1-2009 section 1004.11.3.1.2.2.4 Although not required explicitly, the intent of the code is to provide vanity counter top space equivalent to the non-accessible units. (ICC/A117.1-2009 section 1002.11.2.1) TOP OF PLY LISTED ASSEMBLY:WP 3260INTERIOR - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 11 7/8 TJI @ 16 OC- R 38 BATT INSUL.- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWB(SEE GA FILE NO. FC 5600 INSHEET A.6.02A) - 1 1/2 CONC TOPPING- 3/4" T&G PLY (GLUE & NAIL)- 6 mil. VB- 11 7/8 TJI @ 16 OC- R 38 BATT INSUL.- 1/2" RESILIENT CHANNEL- 2 LAYERS 5/8" TYP X GWB CONTINUOUS VB STRUCTURE (SEE STRUCTURALPLANS) RIM BOARD (HYDROTECH GREEN ROOF SYSTEM-CLASS A.SEE SPEC. AND CERTIFICAITON ON A.6.09)) - 3" GREEN ROOF MATERIAL- TAPERED ROOF INSUL- 3/4" PLY- 11 7/8 TJI @ 16 OC W/ - 5" FOAM - BATT INSUL (R19)- VB- 5/8" GWB 1'-6" - 22 ga. PF FLASHING- 1/2" PLY- 2 LAYERS 5/8" DENS DECK, ALONGNEIGHBORING(SETBACK) WALL AND BEHIND FASCIA-1/2" RS CEDAR PLY 4 1/2" SETBACK TOP OF PLY 2 6 2 6 2 8 2 6 PARAPET EXCEPTIONS PER 2015 IBC 705.11: - SOUTH BUILDINGS:EXCEPTION 2: THE BUILDING HAS AND AREA OF NOT MORE THAT 1,000 SQUARE FEET (93M2) ON ANY FLOOR)-NORTH BUILDING:EXCEPTION 4: ONE-HOUR FIRE-RESISTANCE RATED EXTERIOR WALL THAT TERMINATE AT THE UNDERSIDE OF THEROOF SHEATHING, DECK OR SLAB, PROVIDED: 4.1. WHERE THE ROOF/CEILING FRAMING ELEMENT ARE PARALLEL TO THE WALLS. 4.3. OPENINGS IN THE ROOF SHALL NOT BE LOCATED WITHIN 5 FEET OF THE 1-HOUR FIRE-RESISTANCE- RATED EXTERIOR WALL. 4.4. THE ENTIRE BUILDING SHALL BE PROVIDED WITH NOT LESS THAN A CLASS BE ROOF COVERING. 2 4 2 4 1 HR. FIRE RATEDWALL (REFERENCEASSEMBLY PLAN A.1.14BFOR LISTED ASSEMBLY) SCALE: 1" = 1'-0"26 DETAIL @ ROOF EDGE (FRAMING PARALLEL TO WALL) 2015 IBC 705.11 exception 4 requires the roof to be 1 hour fire rated across the entire span due to the beams running perpendicular to the exterior wall. Openings within 10' of the exterior exit stair require 3/4 hour fire protection (dampers). 2015 IBC 1027.6 Mechanical intake and exhaust must be 10' apart. 2015 IMC 401.4 item 2. Subject: PlanCheck Page: 3 Page Index: 3 Author: nickt Color: File Name: DR 04. MECHANICAL - 9001_MP-revised_08-26-19_stamped-signed.pdf The outside air duct penetrates through several dwelling separation horizontal assemblies. Note 14 mentions a rated chase- does this mean a shaft? If so, revise architecturals to fully detail in plan and section a fire rated shaft complying with 2015 IBC 713. The duct penetration of the shaft will require a fire and smoke damper per 2015 IBC 717.5.3. Alternatively, instead of a shaft, the duct penetration could be accomplished by protecting each through penetration using a listed through penetration firestop system (2015 IBC 717.6.1 which points to 714.4.1.2). Note the requirements on the mechanical plans. Subject: PlanCheck Page: 4 Page Index: 4 Author: nickt Color: File Name: DR 04. MECHANICAL - 9001_MP-revised_08-26-19_stamped-signed.pdf Dryer ducts penetrating dwelling separation floor/ceiling assemblies must be protected with a listed through-penetration fire stop system (2015 IBC 714.4.1.2) Subject: PlanCheck Page: 5 Page Index: 5 Author: nickt Color: File Name: DR 04. MECHANICAL - 9001_MP-revised_08-26-19_stamped-signed.pdf Did you mean the 4XLT-705 fan? Indicate the requirement for the dryer booster fan to be listed to UL 705 on the plans. (2015 IMC 504.5) Subject: PlanCheck Page: 6 Page Index: 6 Author: nickt Color: File Name: DR 04. MECHANICAL - 9001_MP-revised_08-26-19_stamped-signed.pdf The crawlspace does not appear to be heated and is not included as being inside the thermal envelope per the REScheck. Protect this plumbing from freezing. 2015 IPC 305.4 The outside air duct penetrates through several dwelling separation horizontal assemblies. Note 14 mentions a rated chase- does this mean a shaft? If so, revise architecturals to fully detail in plan and section a fire rated shaft complying with 2015 IBC 713. The duct penetration of the shaft will require a fire and smoke damper per 2015 IBC 717.5.3. Alternatively, instead of a shaft, the duct penetration could be accomplished by protecting each through penetration using a listed through penetration firestop system (2015 IBC 717.6.1 which points to 714.4.1.2). Note the requirements on the mechanical plans. Dryer ducts penetrating dwelling separation floor/ceiling assemblies must be protected with a listed through-penetration fire stop system (2015 IBC 714.4.1.2) Did you mean the 4XLT-705 fan? Indicate the requirement for the dryer booster fan to be listed to UL 705 on the plans. (2015 IMC 504.5) The crawlspace does not appear to be heated and is not included as being inside the thermal envelope per the REScheck. Protect this plumbing from freezing. 2015 IPC 305.4 Subject: PlanCheck Page: 6 Page Index: 6 Author: nickt Color: File Name: DR 04. MECHANICAL - 9001_MP-revised_08-26-19_stamped-signed.pdf Please resubmit full sets. There are too many sheets for us to swap out. Please resubmit full sets. There are too many sheets for us to swap out.