Loading...
HomeMy WebLinkAboutFile Documents.230 E Hopkins Ave.0089.2018 (2).ACBK0089-2018-ACBK_BuildingComments_1 Page: A0.3z NET LEASABLE & NET LIVABLE CALCULATIONS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Is the garage for use by the commercial or residential spaces? Is it for use by more than one unit? If only for use by a single residential unit, no accessibility requirements will apply. If for use by more than one unit or for commercial; you must provide a van accessible space. 2015 IBC 1106. ARCHITECTURAL.PDF (43) Page: A0.5z FIRE SEPARATION & THERMAL ENVELOP DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Unless you can detail how the dwelling separation fire partition membranes will extend to the underside of floor or roof sheathing above with no structural penetrations, the 1 hour horizontal assembly will be required to extend across the entire footprint from outside wall to outside wall. Coordinate with structural to ensure no penetrations occur. 2015 IBC 708.4 Page: A0.5z FIRE SEPARATION & THERMAL ENVELOP DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: This portion of the exit enclosure does not stack with the rest of the enclosure. Please thoroughly detail with section cuts going each way to show how you will maintain continuity of the fire barrier. No structural penetrations are permitted; revise structurals as necessary. All supporting construction must also be fire rated. 2015 IBC 707. Page: A0.5z FIRE SEPARATION & THERMAL ENVELOP DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: The corridor serving as exit access for the dwelling unit on the 2nd floor must have a minimum 1/2 hour fire rating. Walls must be constructed as fire partitions (extend uninterrupted to the roof sheathing above or to the underside of an uninterrupted 1/2 hour rated horizontal assembly) and doors must be 20 minute rated. (2015 IBC 1020.1, 716.5) Page: A0.5z FIRE SEPARATION & THERMAL ENVELOP DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: You have numerous vents, pipes, etc running through all stories at the location of the mechanical rooms. Demonstrate how you will protect the penetrations/openings per 2015 IBC 712. If you use a shaft enclosure, detail the construction as a fire barrier. K-692ClairetteFaucetsBrass 105sf 52sf DN DN SLOPEDNUP FEC WHy DW REF ELE L E C . MET E R S MDP FD BrassFaucetsStillnessK-T948-4 UP FEC WHy FD FD SCALE: PROPOSED BASEMENT FLOOR PLAN 1/16" = 1'-0" 2 A0.3 COMM. #6 508 SF AHU 596 SF AHU 365 SF NET MECH. ROOM ELEV. STAIR RESTROOM Revision: Issue: 11.16.2017 P+Z FINAL HE 11.21.2017 FURNITURE P 12.06.2017 COORDINATIO 05.16.2018 COORDINATIO 06.01.2018 REVIEW 07.12.2018 COORDINATIO 08.02.2018 CONSTRUCTI Is the garage for use by the commercial or residential spaces? Is it for use by more than one unit? If only for use by a single residential unit, no accessibility requirements will apply. If for use by more than one unit or for commercial; you must provide a van accessible space. 2015 IBC 1106. WHy WHy ABOVE GARAGEAND CANTILEVEREDFLOORS) BARRIER MAY INCLUDE CLOSED-CELL SPRAY FOAM INSULATION APPLIED TIGHT TO THEUNDERSIDE OF FLOOR SHEATHING AND AT PERIMETER RIM JOISTS IF ALLOWED BYLISTED ASSEMBLY. CRAWL SPACEWALLS WHERE IT OCCURS, EXPOSED EARTH IN UNVENTED CRAWL SPACES SHALL BECOVERED WITH A CLASS I VAPOR RETARDER WITH OVERLAPPING, TAPED JOINTS. SHAFTS,PENETRATIONS ALL PENETRATIONS THROUGH THE EXTERIOR ENVELOPE SHALL BE SEALED WITHCOMPATIBLE SEALANTS, GASKETS, BOOTS, ETC. PENETRATIONS THROUGH THE GWBAIR BARRIER SHALL BE SEALED WITH COMPATIBLE SEALANT, PUTTY, MUD /TAPE ASAPPLICABLE. GARAGESEPARATION GARAGE INTERIOR SHALL BE FULLY SHEATHED IN GWB AND TAPED/SEALED, TYP. RECESSEDLIGHTING FIXTURES RECESSED INTO THE BUILDING THERMAL ENVELOPE SHALL BE IC RATED ANDSEALED TO THE GWB AIR BARRIER PLUMBING ANDWIRING DEVICES/FIXTURES SET INTO THE EXTERIOR BUILDING THERMAL ENVELOPE SHALL BEAIR SEALED. SHOWER/TUB ONEXTERIOR WALL SHOWERS AND TUBS LOCATED AT EXTERIOR WALLS SHALL BE SEPARATED BY AN AIRBARRIER. MIN. 1/2" CEMENT BOARD WITH JOINTS SEALED WITH WATERPROOFINGMEMBRANE OR SIM. REQUIRED. ELECTRICAL/PHONEBOX ON EXT. WALL AIR BARRIER SHALL BE INSTALLED BEHIND BOXES OR AIR-SEALED BOXES SHALL BEINSTALLED. HVAC REGISTERBOOTS HVAC REGISTER BOOTS THAT PENETRATE BUILDING THERMAL ENVELOPE SHALL BESEALED TO THE SUBFLOOR OR GWB SHEATHING, TYP. CONCEALEDSPRINKLERS CONCEALED SPRINKLERS THAT PENETRATE THE AIR BARRIER SHALL HAVEANNULAR SPACED SEALED PER MFR RECOMMENDATIONS SCALE: BASEMENT LEVEL FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 1 A0.5z SCALE: LEVEL ONE FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 2 A0.5z SCALE: ROOF FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 4 A0.5z G F E D C B A 1 2 3 4 5 6 7 1765432GFEDCBA SCALE: LONGITUDINAL SECTION FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 5 A0.5z DN UPFR.REF. PTRY. FEC SCALE: LEVEL 2FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 3 A0.5z SCALE: LONGITUDINAL SECTION FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 6 A0.5z SCALE: TRANSVERSE SECTION FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 7 A0.5z SCALE: TRANSVERSE SECTION FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 8 A0.5z R2 - RESIDENTIAL R2 - RESIDENTIAL R2 - RESIDENTIAL B - BUSINESS B - BUSINESS B - BUSINESS U - UTILITY B - BUSINESS B - BUSINESS R2 - RESIDENTIAL R2 - RESIDENTIAL R2 - RESIDENTIALB - BUSINESS B - BUSINESS R2 - RESIDENTIAL R2 - RES. B - BUSINESS B - BUSINESS B - BUSINESS B - BUSINESS R2 - RESIDENTIAL R2 - RESIDENTIALU - UTILITY File Pa t h : P : \ P r o j - 2 0 1 7 \ 2 1 7 1 8 . 0 0 _ M t n F o r g e \ 0 6 _ D o c u m e n t a t i o n \ 0 1 _ D r a w i n g s \ 2 1 7 1 8 _ A 0 - 5 z . d w g Plot Dat e / T i m e : A u g u s t 0 2 , 2 0 1 8 - 9 : 2 5 a m COPYRIGHT 2018 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGNTHE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT ISTHE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBANDESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIORWRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBANDESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALLRETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,INCLUDING COPYRIGHT THERETO. Revision: SHEET TITLE PROJECT NO: DWG FILE: SCALE: 21718_A0-5z.dwg MTN FORGE RENOVATION AND ADDITION 230-234 E. HOPKINS AVENUE ASPEN, CO 81611 21718 COORDINATION 06.01.2018REVIEW 07.12.2018COORDINATION 08.02.2018CONSTRUCTION DOCUMENTS A0.5z 1/16"=1'-0" FIRE SEPARATION &THERMAL ENVELOPEDIAGRAMS Unless you can detail how the dwellingseparation fire partition membranes willextend to the underside of floor or roofsheathing above with no structuralpenetrations, the 1 hour horizontalassembly will be required to extendacross the entire footprint from outsidewall to outside wall. Coordinate withstructural to ensure no penetrationsoccur. 2015 IBC 708.4 K-692ClairetteFaucetsBrass 105sf 52sf DN DN DN SLOPEDNUP FEC WHy WHy DW REF ELELE C . METER S MDP H L W L TR. P GMEM WHy WHy BrassFaucetsStillnessK-T948-4 UP UP SCALE: LEVEL ONE FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 2 A0.5z UP FEC R2 - RESIDENTIAL R2 - RESIDENTIAL IDENTIAL B - BUSINESS B - BUSINESS U - UTILITY B - BUSINESS B - BUSINESSB - BUSINESS Revision: Issue: 11.16.2017P+Z FINAL HEARING 1830 blake st, ste 200 denver, co 80202303.308.1373 o 303.308.1375 f 234 e hopkins ave aspen, co 81611970.544.9006 o 970.544.3473 f r owland+broughton architecture / urban design / interior design 11.21.2017 FURNITURE PLAN OPTIONS 12.06.2017COORDINATION 05.16.2018COORDINATION 06.01.2018 REVIEW 07.12.2018COORDINATION 08.02.2018CONSTRUCTION DOCUMENTS This portion of the exit enclosure does not stack with the rest of the enclosure. Please thoroughly detail with section cuts going each way to show how you will maintain continuity of the fire barrier. No structural penetrations are permitted; revise structurals as necessary. All supporting construction must also be fire rated. 2015 IBC 707. H WHy SCALE: BASEMENT LEVEL FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 1 A0.5z SCALE: LEVEL ONE FIRE SEPARATION DIAG 1/16" = 1'-0" 2 A0.5z ROOF DN UP FR. REF. PTRY. FEC LEVEL 2 R2 - RESIDENTIAL R2 - RESIDENTIAL B - BUSINESS The corridor serving as exit access for the dwelling unit on the 2nd floor must have a minimum 1/2 hour fire rating. Walls must be constructed as fire partitions (extend uninterrupted to the roof sheathing above or to the underside of an uninterrupted 1/2 hour rated horizontal assembly) and doors must be 20 minute rated. (2015 IBC 1020.1, 716.5) K-692ClairetteFaucetsBrass 105sf 52sf DN DN DN SLOPEDNUP FEC WHy WHy DW REF ELELE C . METER S MDP H L W L TR. P GMEM WHy WHy FDFD FD BrassFaucetsStillnessK-T948-4 DN DN UP UP UP FD FEC WHy FD FD FD FD FD SCALE: BASEMENT LEVEL FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 1 A0.5z SCALE: LEVEL ONE FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 2 A0.5z SCALE: ROOF FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 4 A0.5z DN UP FR. REF. PTRY. FEC SCALE: LEVEL 2FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 3 A0.5z R2 - RESIDENTIAL R2 -RESIDENTIAL R2 - RESIDENTIAL R2 - RESIDENTIAL R2 - RESIDENTIAL B - BUSINESS B - BUSINESS B - BUSINESS U - UTILITY B - BUSINESS B - BUSINESSB - BUSINESS Revision: Issue: MTN FORGE RENOVATION AND ADDITION 11.16.2017P+Z FINAL HEARING 1830 blake st, ste 200 denver, co 80202303.308.1373 o303.308.1375 f 234 e hopkins ave aspen, co 81611970.544.9006 o970.544.3473 f rowland+broughton architecture / urban design / interior design 11.21.2017FURNITURE PLAN OPTIONS 12.06.2017COORDINATION 05.16.2018COORDINATION 06.01.2018REVIEW 07.12.2018COORDINATION 08.02.2018CONSTRUCTION DOCUMENTS You have numerous vents, pipes, etc running through all stories at the location of the mechanical rooms. Demonstrate how you will protect the penetrations/openings per 2015 IBC 712. If you use a shaft enclosure, detail the construction as a fire barrier. Page: A0.5z FIRE SEPARATION & THERMAL ENVELOP DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Page: A0.5z FIRE SEPARATION & THERMAL ENVELOP DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: The interior exit stair must be separated from the exit passageway by a 1 hour fire barrier and 60 minute fire rated door. (2015 IBC 1023.3.1 and 716.5) Page: A0.5z FIRE SEPARATION & THERMAL ENVELOP DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Why is this portion of the exterior wall fire rated? Property line separation distance may be measured to the center of the street. (2015 IBC 202) Page: A0.5z FIRE SEPARATION & THERMAL ENVELOP DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: The walls, ceiling, and floor of the covered area just outside the exit must be protected with the same level of protection as the exit enclosure until the path of egress is open to the sky. Once open to the sky, the travel becomes exit discharge (egress court in this case due to the narrow width against the property line) requiring 1 hour rating for 10' up until the alley. Please detail this and demonstrate in the fire ratings plan. 2015 IBC 1022, 1028. Page: A0.5z FIRE SEPARATION & THERMAL ENVELOP DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Trash containers of 1.5 cubic yard or greater capacity require walls, openings, and overhangs within 5' to be non-combustible (or comply with one of the exceptions). Demonstrate compliance. 2015 IFC 304.3.3 and 304.3.4. H L W FDFD FD BrassFaucetsStillnessK-T948-4 DN DN UP UP UP FD FEC WHy FD FD FD FD FD R2 - RESIDENTIAL B - BUSINESS B - BUSINESS B - K-692ClairetteFaucetsBrass 105sf 52sf DN DN DN SLOPEDNUP FEC WHy WHy DW REF ELELE C . METE R S MDP H L W L TR. P GMEM BrassFaucetsStillnessK-T948-4 UP UP FEC FD FD FD FD R2 - RESIDENTIAL R2 - RESIDENTIAL B - BUSINESS B - BUSINESS U - UTILITY B - BUSINESSB - BUSINESS The interior exit stair must be separated from the exit passageway by a 1 hour fire barrier and 60 minute fire rated door. (2015 IBC 1023.3.1 and 716.5) FDFD FD DN DN UP FD WH y FD FD EGEND SSEMBLY STIC STC B - BUSINESS Why is this portion of the exterior wall fire rated? Property line separation distance may be measured to the center of the street. (2015 IBC 202) K-692ClairetteFaucetsBrass 105sf 52sf DN DN DN SLOPEDNUP FEC WHy WHy DW REF ELE L E C . MET E R S MDP L TR. P GMEM R2 - RESIDENTIAL B - BUSINESS U - UTILITY B - BUSINESSBUSINESS Issue: 11.16.2017 P+Z FINAL HEARING 1830 blake st, ste 200 denver, co 80202 303.308.1373 o 303.308.1375 f 234 e hopkins ave aspen, co 81611 970.544.9006 o 970.544.3473 f ro w la nd+bro ugh to n architecture / urban design / interior design 11.21.2017 FURNITURE PLAN OPTIONS 12.06.2017 COORDINATION 05.16.2018 COORDINATION 06.01.2018 REVIEW The walls, ceiling, and floor of the covered area just outside the exit must be protected with the same level of protection as the exit enclosure until the path of egress is open to the sky. Once open to the sky, the travel becomes exit discharge (egress court in this case due to the narrow width against the property line) requiring 1 hour rating for 10' up until the alley. Please detail this and demonstrate in the fire ratings plan. 2015 IBC 1022, 1028. K-692ClairetteFaucetsBrass 105sf 52sf DN DN DN SLOPEDNUP FEC WHy WHy DW REF ELELEC . METER S MDP H L W L TR. P GMEM WHy WHy BrassFaucetsStillnessK-T948-4 UP UP FD SCALE: LEVEL ONE FIRE SEPARATION DIAGRAM 1/16" = 1'-0" 2 A0.5z DN UP FEC R2 - RESIDENTIAL R2 - RESIDENTIAL SIDENTIAL R2 - RESIDENTIAL B - BUSINESS B - BUSINESS U - UTILITY B - BUSINESS B - BUSINESSB - BUSINESS Revision: Issue: 11.16.2017P+Z FINAL HEARING 1830 blake st, ste 200 denver, co 80202303.308.1373 o 303.308.1375 f 234 e hopkins ave aspen, co 81611970.544.9006 o 970.544.3473 f rowland+broughtonarchitecture / urban design / interior design 11.21.2017 FURNITURE PLAN OPTIONS 12.06.2017COORDINATION 05.16.2018COORDINATION 06.01.2018 REVIEW 07.12.2018COORDINATION 08.02.2018CONSTRUCTION DOCUMENTS Trash containers of 1.5 cubic yard or greater capacity require walls, openings, and overhangs within 5' to be non-combustible (or comply with one of the exceptions).Demonstratecompliance. 2015 IFC304.3.3 and 304.3.4. Page: A0.6z PLUMBING & EGRESS DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Your design complies, but here's how we'd typically calculate: Commercial unit 1 has an occupant load of less than 15 and an exclusive single user toilet room. This satisfies the toilet requirements for unit 1. (2015 IBC 2902.2) Commercial unit 7 has the same situation. The total number of occupants minus the residential units and commercial units 1 and 7 is 34. 34/2 = 17 males, 17 females. Requirement is for 1 toilet and 1 lav for males, and one each for females. Single user unisex toilet rooms may be used instead as you show. Page: A0.6z PLUMBING & EGRESS DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Add an egress diagram for the occupied roof deck. If the roof deck is only for use by the free market residential unit, it may be considered an R2 occupancy. If it is for use by more than one unit or by commercial, it will be considered an assembly occupancy and will be required to be fully accessible. This includes the spas if commercial. Page: A0.6z PLUMBING & EGRESS DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: The designated trash area of 105 sqft appears to encroach on the minimum required egress width of 44". (2015 IBC 1028.4) Page: A0.6z PLUMBING & EGRESS DIAGRAMS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Include occupant loads for the mechanical rooms at 300sqft per person per 2015 IBC 1004. Include these occupants in your plumbing fixture calcs as well. DN yA-DEMO-WALL-RAILA-DEMO-WALL-FIREA-DEMO-WALL-PATTA-DEMO-FLOR-EQPM-NICA-DEMO-FLOR-MECHA-DEMO-FLOR-ELECA-DEMO-FLOR-BELOA-DEMO-FLOR-MILL-BELOA-DEMO-FLOR-PATT-9A-DEMO-FLOR-EDGEA-DEMO-DOOR-OVHDA-DEMO-DOOR-JAMBA-DEMO-PLUM-FIXTS-DEMO-COLSS-DEMO-COLS-OVHDA-EXST-WALLA-EXST-WALL-PRHTA-EXST-WALL-RAILA-EXST-WALL-FIREA-EXST-WALL-FOOTA-EXST-WALL-FNDNA-EXST-WALL-PATTA-EXST-WALL-FRAMA-EXST-FLOR-EQPMA-EXST-FLOR-EQPM-NICA-EXST-FLOR-MECHA-EXST-FLOR-ELECA-EXST-FLOR-OVHDA-EXST-FLOR-LOWA-EXST-FLOR-BELOA-EXST-FLOR-MILLA-EXST-FLOR-MILL-BELOA-EXST-FLOR-MILL-OVHDA-EXST-FLOR-PATT-9A-EXST-FLOR-EDGEA-EXST-GLAZA-EXST-GLAZ-SILLA-EXST-GLAZ-OVHDA-EXST-DOORA-EXST-DOOR-OVHDA-EXST-DOOR-JAMBA-EXST-STRSA-EXST-STRS-RAILA-EXST-STRS-TEXTA-EXST-FURNA-EXST-PLUM-FIXTS-EXST-COLSS-EXST-COLS-OVHD UP DN UP FEC SCALE: PROPOSEDBASEMENT FLOOR PLAN 3/32" = 1'-0" 1 A0.2z SCALE: PROPOSEDLEVEL ONE FLOOR PLAN 3/32" = 1'-0" 2 A0.2z SCALE: PROPOSEDLEVEL TWO FLOOR PLAN3/32" = 1'-0"3A0.2z COMM. #739'-7" EGRESS COMM. #634'-2" EGRESS STAIRRES. #1107'-8" EGRESS PER IBC 2015 1006.2.1 TWO EXITS AND EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE PROVIDED WHERE THE DESIGN OCCUPANT LOAD OR COMMON PATH OF EGRESS TRAVELDISTANCE EXCEEDS THE VALUES LISTED IN TABLE 1006.2.1 FUNCTION OF SPACE OL MECHANICAL 30 BUSINESS 10 RESIDENTIAL 20 THE ABOVE REPRESENTS THE APPLI FUNCTIONS IN THIS BUILDING. COMM. #7 345 SF4 OCCUPANTS 122 SF2 OCC. PLUMBING FIXTURE CALCULATIONS PLUMBING FIXTURES :52 OCCUPANTS REQ'D OCCUPANCY: BUSINESS GROUP B 1 WATER CLOSETS 1 PER 25 FOR THE FIRST 50 AND 1 PER 50 COMMERCIAL RESTROOMS IN #1, #7 FOR THE REMAINDER EXCEEDING 50 34 OCCUPANTS REMAINING - 2 REQUIRED, 3 PROVIDED LAVATORIES 1 PER 40 FOR THE FIRST 80 AND 1 PER 80 COMMERCIAL RESTROOMS IN #1, #7FOR THE REMAINDER EXCEEDING 80 34 OCCUPANTS REMAINING, 1 REQUIRED, 3 PROVIDED WATER COOLER 1 PER 100 1 REQUIRED, 2 PROVIDED File P a t h : P : \ P r o j - 2 0 1 7 \ 2 1 7 1 8 . 0 0 _ M t n F o r g e \ 0 6 _ D o c u m e n t a t i o n \ 0 1 _ D r a w i n g s \ 2 1 7 1 8 _ A 0 - 6 z . d w g Plot Da t e / T i m e : A u g u s t 0 2 , 2 0 1 8 - 8 : 5 3 a m Your design complies, but here's how we'd typically calculate: Commercial unit 1 has an occupant load of less than 15 and anexclusive single user toilet room. This satisfies the toiletrequirements for unit 1. (2015 IBC 2902.2) Commercial unit 7 has the same situation. The total number of occupants minus the residential units andcommercial units 1 and 7 is 34. 34/2 = 17 males, 17 females. Requirement is for 1 toilet and 1 lav for males, and one each for females. Single user unisex toilet rooms may be usedinstead as you show. SCALE: PROPOSED LEVEL ONE FLOO 3/32" = 1'-0" 2 A0.2z BC 2015 1006.2.1 TWO EXITS AND EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BE DED WHERE THE DESIGN OCCUPANT LOAD OR COMMON PATH OF EGRESS TRAVEL NCE EXCEEDS THE VALUES LISTED IN TABLE 1006.2.1 1 Add an egress diagram for the occupied roof deck. If the roof deck is only for use by the free market residential unit, it may be considered an R2 occupancy. If it is for use by more than one unit or by commercial, it will be considered an assembly occupancy and will be required to be fully accessible. This includes the spas if commercial. 105sf MM. #3 30 SF CUPANTS 1 The designated trash area of 105 sqft appears to encroach on the minimum required egress width of 44". (2015 IBC 1028.4) A-SYMBA-SYMB-DOORA-SYMB-GLAZA-SYMB-ASMBA-SYMB-GRIDA-SYMB-ROOMA-SYMB-TITLA-SYMB-ROOFA-SYMB-CLNGA-SYMB-REV1A-SYMB-PR01A-SYMB-ASI1A-TEXTA-GRIDA-TBLK-TEXTA-AREA-PATTXGEN-TBLKXGEN-NOTEXGEN-LGNDXREF-FLR1XREF-ROOFXREF-SITEXREF-IMAGXREF-EXST-FLR0XREF-DEMO-FLR0XREF-GRIDXREF-EXST-FLR1XREF-EXST-FLR2XREF-EXST-ROOFXREF-DEMO-FLR1XREF-DEMO-FLR2XREF-DEMO-ROOF DN DN FEC A-DEMO-WALL-RAILA-DEMO-WALL-FIREA-DEMO-WALL-PATTA-DEMO-FLOR-EQPM-NICA-DEMO-FLOR-MECHA-DEMO-FLOR-ELECA-DEMO-FLOR-BELOA-DEMO-FLOR-MILL-BELOA-DEMO-FLOR-PATT-9A-DEMO-FLOR-EDGEA-DEMO-DOOR-OVHDA-DEMO-DOOR-JAMBA-DEMO-PLUM-FIXTS-DEMO-COLSS-DEMO-COLS-OVHDA-EXST-WALLA-EXST-WALL-PRHTA-EXST-WALL-RAILA-EXST-WALL-FIREA-EXST-WALL-FOOTA-EXST-WALL-FNDNA-EXST-WALL-PATTA-EXST-WALL-FRAMA-EXST-FLOR-EQPMA-EXST-FLOR-EQPM-NICA-EXST-FLOR-MECHA-EXST-FLOR-ELECA-EXST-FLOR-OVHDA-EXST-FLOR-LOWA-EXST-FLOR-BELOA-EXST-FLOR-MILLA-EXST-FLOR-MILL-BELOA-EXST-FLOR-MILL-OVHDA-EXST-FLOR-PATT-9A-EXST-FLOR-EDGEA-EXST-GLAZA-EXST-GLAZ-SILLA-EXST-GLAZ-OVHDA-EXST-DOORA-EXST-DOOR-OVHDA-EXST-DOOR-JAMBA-EXST-STRSA-EXST-STRS-RAILA-EXST-STRS-TEXTA-EXST-FURNA-EXST-PLUM-FIXTS-EXST-COLSS-EXST-COLS-OVHD DN DN UP UP UP FEC DN UP FEC SCALE: PROPOSEDBASEMENT FLOOR PLAN 3/32" = 1'-0" 1 A0.2z SCALE: PROPOSEDLEVEL ONE FLOOR PLAN 3/32" = 1'-0" 2 A0.2z SCALE: PROPOSEDLEVEL TWO FLOOR PLAN 3/32" = 1'-0" 3 A0.2z COMM. #7 39'-7" EGRESS COMM. #1 38'-5" EGRESS COMM. #2 23'-8" EGRESS COMM. #634'-2" EGRESS COMM. #4 63'-0" EGRESS COMM. # 6 45'-10" EGRESS STAIRRES. #1 107'-8" EGRESS PER IBC 2015 1006.2.1 TWO EXITS AND EXIT ACCESS DOORWAYS FROM ANY SPACE SHALL BEPROVIDED WHERE THE DESIGN OCCUPANT LOAD OR COMMON PATH OF EGRESS TRAVEL DISTANCE EXCEEDS THE VALUES LISTED IN TABLE 1006.2.1 COMM. #534'-0" EGRESS COMM. #3 52'-4" EGRESS COMM. #4 1,322 SF 14 OCCUPANTS COMM. #6 495 SF 5 OCCUPANTS122 SF 2 OCC. COMM. #2 311 SF 4 OCCUPANTS COMM. #3 630 SF7 OCCUPANTS COMM. #1 1,365 SF 14 OCCUPANTS COMM. #7 345 SF 4 OCCUPANTS 122 SF 2 OCC. PLUMBING FIXTURE CALCULATIONS PLUMBING FIXTURES :52 OCCUPANTS REQ'D OCCUPANCY: BUSINESS GROUP B 1 WATER CLOSETS 1 PER 25 FOR THE FIRST 50 AND 1 PER 50 COMMERCIAL RESTROOMS IN #1, #70-6 z . d w g Include occupant loads for the mechanical rooms at 300sqft perperson per 2015 IBC1004. Include theseoccupants in your plumbing fixture calcs as well. Page: A1.2 PROPOSED SNOWMELT & REMP SHEET File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Provide documentation showing that the proposed spas are either CEC or APSP-14 listed. Otherwise, it will be subject to RREMP. Ord. 40, 2016. Page: A2.0 PROPOSED BASEMENT FLOOR PLAN File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Detail the kitchenette in commercial unit 4 to demonstrate compliance with accessibility requirements. 2015 IBC 1109.4. Page: A2.0 PROPOSED BASEMENT FLOOR PLAN File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Provide handrails on both sides of all stairs. 2015 IBC 1011.11 Page: A2.1 PROPOSED LEVEL ONE FLOOR PLAN File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Commercial 1 bathroom must be accessible. Demonstrate compliance (including the width of the door which you have not specified in the door schedule). 2015 IBC 1109.2. Page: A2.1 PROPOSED LEVEL ONE FLOOR PLAN File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: If garage must be accessible (see comment on Net Leasable drawings), door 1/103 must also be accessible. Provide door maneuvering clearances. ICC A117.1-2009 section 404.2.3.1 ELEVATOR 6:12 12:12 12:12 6:12 12: 1 2 12: 1 2 20'-0" SETBACK FOR10'-0" OVERRUN FORELEVATOR & STAIR 15'-0" SETBACK FOR6'-0" MECHANICALEQUIPMENT DN MEMBRANE ROOF MEMBRANE ROOF ME M B R A N E R O O F MODULAR GREENROOF DN RD OD DS DN DNDN RD OD DN DN 20' - 0 " S E T B A C K F O R 10'- 0 " O V E R R U N F O R ELE V A T O R & S T A I R 15'- 0 " S E T B A C K F O R 6'-0 " M E C H A N I C A L EQ U I P M E N T RD OD DN DN DN DN 10-0" SETBACK FORPERMANENT ROOFTOPAMENITIES - 5' HEIGHT 10- 0 " S E T B A C K F O R PER M A N E N T R O O F T O P AM E N I T I E S - 5 ' H E I G H T RD OD UP U/CREF U/CWINE U/CICE UP WHy WHy DS DN RD OD DN DN DN RD OD DN DNDN DN RD OD DN DN DN RD OD DN DNDN RIVER ROCK BALLASTAROUND DRAINS SCALE: PROPOSED SNOWMELT LEVEL ONE & SITE PLAN 3/32" = 1'-0" 2 A1.2 SCALE: PROPOSED SNOWMELT ROOF LEVEL 3/32" = 1'-0" 4 A1.2 WMELT WO NOWMELT EXEMPT SNOWMELT SNOWMELT AREA - ROOF LEVEL 0 SF PROPOSED SNOWMELT1,027 SF EXEMPT SNOWMELT SNOWMELT AREA - LEVEL ONE / SITE 111 SF PROPOSED SNOWMELT379 SF DROP-IN HOT TUB - WATERSURFACE AREA = 40 SF 1027SF DROP-IN HOT TUB - WATER SURFACE AREA = 40 SF COPYRIGH THE INFO THE PROP DESIGN. N WRITTEN DESIGN. R RETAIN AL INCLUDING SHEE PROJ DWG SCA 21718 MT RE AN 230- ASP 21718 A PR SN & R Provide documentation showing that the proposed spas are either CEC or APSP-14 listed. Otherwise, it will be subject to RREMP. Ord. 40, 2016. 007 FDFD FD DN DN FD FEC WH y FD FD SE T B A C K L I N E COMM.UNIT 4 001 COURTYARD 000 COMM.UNIT 5 007 ELEVATOR 1 COMM. 3 CORRIDOR 017 3'- 2 " COMM. UNIT 6 016 3'-4" RESTROOM 015 003 005 018 BEDROOM 002 1/001 1/017 1/007 2/002 1/002 1/015 1/016 001 ABV. 002 ABV.GUARD RAIL 004 ABV. 006 ABV. 009008 ABV. EXIST COLUMN 011010 ABV. 013012 015014 ABV. 016 ABV. 017 W17F A7.01 W13 A7.02 W16 A7.02 W6 A7.01 2 T. O. SLAB.(E) 88'-10 5/8" W4 A7.01 W4 A7.01 W1 W13 A7.02 DF 2 A6.12 W5 A7.01 W5 A7.01 Detail the kitchenette in commercial unit 4 to demonstrate compliance with accessibility requirements. 2015 IBC 1109.4. 007 FDFD FD DN DN FD WH y FD SE T B A C K L I N E COMM. UNIT 4 001 COURTYARD 000 003 005 1/001 001 ABV. 002 ABV. GUARD RAIL 004 ABV. 006 ABV. 009008 ABV. EXIST COLUMN 011010 ABV. 013012 015014 ABV. 016 ABV. 017 2 A6.23 T. O. SLAB.(E) 88'-10 5/8" W A7 W1 A7.01 W5 A7.01 W5 A7.01 Provide handrails on both sides of all stairs. 2015 IBC 1011.11 NE PROPERTY LINE SETBACK LINE SE T B A C K L I N E P K-692ClairetteFaucetsBrass DN DN DN SLOPE DNUP FEC WH y WH y DW REF EL E L E C . ME T E R S MD P NEW MECH CHASE COMM.UNIT 1 100 GARAGE 103 COMM. 1BATHROOM 101 ENTRYLOBBY 109 STAIR #1 104 RESTROOM 106 AHU 102 AHU WINDOW WELL OPEN TO BELOW TR A S H / R E C Y C L I N G NE W K I T C H E N L A Y O U T 115 124 1/100 1/101 1/102 1/103 1/104 2/104 2/1071/108 1/106 ELEVATOR 1 2/100 2 3 11 112 113 114 122121120119118117116 123 ABV. 125 126 ABV. PLY. " (E) T. O. PLY.(E) 100'-0" T. O. PLY. 100'-0" T. O. PLY. 99'-6" 99'-6" T. O. TOPPING SLAB 100'-0" W15 SIM. A7.02 2 A6.25 W8F A7.01 W15 SIM. A7.02 W9 A7.01 A W8 A7.01 W8 A7.01 W12 A7.01 W12 A7.01 T. O. PLY. (E) 100'-0" T. O. STRUCT. SLAB 99'-3" W7 A7.01 HALL 105 W10 A7.01 DF W7 A7.01 1 A6.23 114 ABV.6 A7.10 6 A7.10 FA C P RAISED PLANTER Commercial 1 bathroom must be accessible. Demonstrate compliance (including the width of the door which you have not specified in the door schedule). 2015 IBC 1109.2. 4 1 A4.2 2 6 60 ' - 0 " 6'- 1 0 " 17 ' - 1 1 1 / 4 " 6'- 7 1 / 4 " 15 ' - 0 3 / 4 " 3 5 PR O P E R T Y L I N E PROPERTY LINE SETBACK LINE SE T B A C K L I N E SETBACK LINE AL L E Y 2 A5.1 7 5'- 5 3 / 8 " 8'- 1 3 / 8 " 1 A5.1 EX I S T I N G AD D I T I O N K-692ClairetteFaucetsBrass 105sf 52sf DN DN SLOPE DNUP WH y WH y DW REF EL E L E C . MET E R S MD P TRASH/RECYCLINGMETERS NEW MECH CHASE GARAGE 103 COMM. 1BATHROOM 101 STAIR #1 104 AHU 102 AHU WINDOW WELL OPEN TO BELOW TR A S H / R E C Y C L I N G NE W K I T C H E N L A Y O U T 124 1/101 1/102 1/103 1/104 2/104 1/107 ELEVATOR 1 2/100 2/103 3/103 122121120119 123 ABV. 125 126 ABV. T. O. PLY. 100'-0" T. O. PLY. 99'-6" T. O. TOPPING SLAB 99'-6" A6.21 T. O. TOPPING SLAB 100'-0" W14 A7.02 W14 A7.02 W15 SIM. A7.02 W8F A7.01 W15 SIM. A7.02 W9 A7.01 W8F A7.01 W8 A7.01 W8 A7.01 W8 A7.01 W8 A7.01 W12 A7.01 T. O. STRUCT. SLAB 99'-3" W3 A7.01 HALL 105 W10 A7.01 1 A6.23 6 A7.10 SIM. W3 A7.01 FA C P Re M R A 23 AS 12 CO 05 CO 06 RE 07 CO 08 CO If garage must be accessible (see comment on Net Leasable drawings), door 1/103 must also be accessible. Provide door maneuvering clearances. ICC A117.1-2009 section 404.2.3.1 Page: A2.2 PROPOSED LEVEL TWO FLOOR PLAN File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Restroom 222 must be accessible. Demonstrate compliance. 2015 IBC 1109.2. Page: A2.2 PROPOSED LEVEL TWO FLOOR PLAN File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Revise to correctly show door maneuvering clearances at doors 1/214 and 1/213. ICC A117.1-2009 section 404.2.3.2. Page: A2.3 PROPOSED ROOF PLAN File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Provide installation instructions for the gas fire pit and demonstrate compliance with the required clearances. Page: A2.3 PROPOSED ROOF PLAN File Name: ARCHITECTURAL.PDF Subject: hot tub guard Author: nickt Color: Detail the height of the parapet above the hot tub edge. If the hot tub edge is 18" or less in width, then the parapet must be at least 18" above it. If the width is greater than 18", the guard must be at least 42" above per City Policy. Page: A2.3 PROPOSED ROOF PLAN File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Provide the riser height of the steps at the roof deck and provide handrails. 60 ' - 0 " 1/ 4 " 6'- 7 1 / 4 " 15 ' - 0 3 / 4 " PROPERTY LINE SETBACK LINE AL L E Y 5'- 5 3 / 8 " 8'- 1 3 / 8 " EX I S T I N G AD D I T I O N DN UP DRAWERS BELOWHANGING CLOSET FEC STAIR #1 217 COMMERICALUNIT 6 221 GUESTSUITE 219 CH. 3 18 TOROSET 13 3/219 1/221 1/217 1/218 220 220 221 222 223 223 223 O. PLY. '-1 3/8" T. O. PLY. RESTROOM 222 1/220 1/222 BATH 220 W8F A7.01 W8 A7.01 W14 A7.02 2/219 GUESTSUITE 212 W10 A7.01 W10 A7.01 W10 A7.01 W8 A7.01 13 Restroom 222 must be accessible. Demonstrate compliance. 2015 IBC 1109.2. PROPERTY LINE SETBACK LINE EXISTING ADDITION TING ROOF BELOW DN UP T/RDW FR. REF. MW PTRY. STORAGE 214 STAIR #1 217 COMMERICAL UNIT 6 221 RESIDENCE KITCHEN 202 61 GSF JANITOR CLOSET 213 1/217 1/213 1/214 ELEVATOR 1 224225 UTILITY 215 1/215 3 A6.21 RESTROOM 222 3 A6.25 1/222 RESIDENCE W8F A7.01 W14 A7.02 W8F A7.01 W10 A7.01 Revise to correctly show door maneuvering clearances at doors 1/214 and 1/213. ICC A117.1-2009 section 404.2.3.2. ELEVATOR 12 : 1 2 12 : 1 2 20 ' - 0 " 10 ' - 0 " EL E V 15 ' - 0 " 6'- 0 " M EQ U I DN DN DN 10 - 0 " PE R M AM E N UP UP WH y DS DN RD OD DN DN LEVEL TWO DECK BELOW METAL ROOF R D 3 ROOF BELOW ROOF BE T. O. PARAPET 126'-7" T. O. PARAPET 126'-7" W A 2 A6.11 GAS F.P. FLUE BANQUETTE GAS FIRE PIT 6 PERSON PRE-FAB DROP IN HOT TUB W FENCE Provide installation instructions for the gas fire pit and demonstrate compliance with the required clearances. 12 : 1 2 20 ' - 0 " S E T B A C K F O R 10 ' - 0 " O V E R R U N F O R EL E V A T O R & S T A I R 6'- 0 " M E C H A N I C A L EQ U I P M E N T UP U/C REF U/C WINE U/C ICE DS DN RD OD DN DN 26'-4 3/4"14'-8 1/2" PROPERTY LINE SETBACK LINE 5'-8 1/8" EXISTING ADDITION ETAL ROOF ROOF BELOW 4 & 5 A6.21T. O. PARAPET 126'-7"W-14 A7.02 BANQUETTE 6 PERSON PRE-FAB DROP IN HOT TUB Detail the height of the parapet above the hot tub edge. If the hot tub edge is 18" or less in width, then the parapet must be at least 18" above it. If the width is greater than 18", the guard must be at least 42" above per City Policy. ELEVATOR 6:12 12:12 12:12 6:12 12 : 1 2 12 : 1 2 DN MEMBRANE ROOF MEMBRANE ROOF ME M B R A N E R O O F MODULAR GREEN ROOF DN RD OD DS DN DNDN RD OD DN DN 20 ' - 0 " S E T B A C 10 ' - 0 " O V E R R U EL E V A T O R & S 15 ' - 0 " S E T B A C 6'- 0 " M E C H A N I EQ U I P M E N T RD OD DN DN DN DN 10 - 0 " S E T B A C K PE R M A N E N T R AM E N I T I E S - 5 RD OD UP U/C REF U/C WINE U/C ICE UP WH y WHy DS DN RD OD DN DN DN RD OD DN DNDN DN RD OD DN DN DN RD OD DN DNDN PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PROPERTY LINE SETBACK LINE SE T B A C K L I N E SETBACK LINE SE T B A C K L I N E LEVEL TWODECK BELOW METAL ROOF METAL ROOF METAL ROOF MECHVENTROOFDECK 301 PLANTER T. O. DECK "A"121'-11 3/8" T. O. PARAPET126'-7" ROOF BELOW LEVEL TWO DECK BELOW ROOF BELOW ROOF BELOW 4 & 5 A6.21T. O. PARAPET126'-7" T. O. PARAPET126'-7" W-14 A7.02 W-14A7.02 W-13A7.02 2 A6.11 GAS F.P. FLUE T.O. SHEATHING 122'-9 3/8" T.O. SHEATHING121'-3 3/8" T.O. (E) SHEATHING 121'-3 3/8" T.O. (E) SHEATHING 121'-3 3/8" T. O. PARAP 123'-4" T. O. PARAP 126'-7" BANQUETTE GAS FIRE PIT 6 PERSON PRE-FAB DROP IN HOT TUB 6 PERSON PRE-FABDROP IN HOT TUB GA S F I R E P I T OUTDOORKITCHEN 302 STAIR 1 303 4 A6.25 ROOF DRAINS BELOW LEVEL PAVER DECK, TYP. 1/303 WATER FEATURE BASIN SNOW FENCE Provide the riser height of the steps at the roof deck and provide handrails. Page: A3.0 PROPOSED BASEMENT RCP File Name: ARCHITECTURAL.PDF Subject: Smoke Alarms Author: nickt Color: Show the location of smoke alarms and carbon monoxide detectors on the RCPs per 2015 IBC 907.2.11 and Municipal Code Title 8. Page: A4.2 PROPOSED EXTERIOR ELEVATIONS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Provide a diagram of the north elevation demonstrating compliance with 2015 IBC 705.8. Be sure to measure each floor separately. Page: A5.2 PROPOSED BUILDING SECTIONS File Name: ARCHITECTURAL.PDF Subject: Group Author: nickt Color: The dwelling separation needs to be continuous. Either make R2 1 hour fire rated or detail another method for keeping a fire from spreading in the direction of the arrow I've drawn. 2015 IBC 708, 711. Page: A5.2 PROPOSED BUILDING SECTIONS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Provide parapets at all exterior walls required to be rated due to proximity to property line (or demonstrate how you meet one of the exceptions). 2015 IBC 705.11. Page: A5.2 PROPOSED BUILDING SECTIONS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: This wall is a dwelling separation wall. This makes it a fire partition which must extend to the underside the roof sheathing without interruption by structure OR to the underside of a 1 hour fire rated horizontal assembly ceiling. Also, please provide a callout for the wall assembly type. 2015 IBC 708.4. BrassFaucetsStillnessK-T948-4 UP FD R1 R2 S1 S1 R1 R1 R1 D1 R1R1R1 R1 R1 R1 R1 R1 R1 EF1 8'-8" 8'-8" 8'-8" 8'-8" OPEN AHU 004 M BEDROOM 003 MECH & STORAGE 005 AHU BATH 006 1.LAYOUT SHOWN HEREIN IS FOR DESIGN INTENT ONLY AND DOES NOT SHOW FULL ELECTRICAL SCOPE. REFER ALSO TO ELECTRICAL ENGINEERING DOCUMENTATION.. 2.CONTRACTOR TO PROVIDE PROPER BLOCKING AT ALL WALL-MOUNTED AND CEILING-HUNG FIXTURES IN SCOPE AND BY FF&E OR OWNER. 3.WHEN DIMMING IS A REQUIREMENT, CONTRACTOR TO INSTALL PROPER WIRING. 4.COORDINATE ALL SWITCH AND DEVICE MOUNTING HEIGHTS WITH ARCHITECT PRIOR TO ROUGH IN. 5.ELECTRICAL COVER PLATES AND DEVICES TO BE PRICED AS LUTRON "DECORA" STYLE APPEARANCE. COLOR TBD PER INTERIOR DESIGNER. 6.OUTLETS FOR APPLIANCES NOT SHOWN. CONTRACTOR TO COORDINATE ELECTRICAL REQUIREMENTS FOR ALL APPLIANCES - REF. APPLIANCE SCHEDULE. 7.CONTRACTOR TO COORDINATE ELECTRICAL REQUIREMENTS FOR ALL MECHANICAL EQUIPMENT. REFER TO MECHANICAL ENGINEERING DOCUMENTS FOR EQUIPMENT SPECIFICATIONS. 8.CONVENTIONAL SWITCHES TO BE PROVIDED FOR EACH FIREPLACE UNIT FOR SAFETY. 9.PROVIDE WALL AND FLOOR RECEPTACLES AS REQUIRED BY CODE. RECEPTACLES SHOWN IN PLANS ARE FOR GENERAL LAYOUT ONLY AND ARE NOT COMPREHENSIVE. PROVIDE GFCI RECEPTACLES WHERE REQUIRED. GENERAL LIGHTING NOTES WITCH C.) WITCH CY SENSOR CH OUTLET R OUTLET APPLICABLE) HIGH EFFICACY LAMPS MINIMUM 75% OF A HIGH EFFICACY LA CFL LAMPS, T-8 OR FLUORESCENT TU EFFICACY OF: 1.60 LUMENS PER W 2.50 LUMENS PER W 40W, AND 3.40 LUMENS PER W 1.1.SMOKE DETEC 1.2.CARBON MONO 1.3.SPRINKLER HE 1.4.FIRE ALARM P 1.5.HORN AND STR 2.COORDINATE LOCA LIFE SAFTEY DEVIC ALIGN WHERE POS FOR ITEMS WHERE 3.GC TO SUBMIT FIR DRAWINGS FOR AR ROUGH IN. 4.SPRINKLER HEADS WITH FINISH TO MA VARIES Show the location of smoke alarms and carbon monoxide detectors on the RCPs per 2015 IBC 907.2.11 and Municipal Code Title 8. SCALE: PROPOSEDEXTERIOR ELEVATION - NORTH3/16" = 1'-0"1A4.2 1 2 6 7 60'-0" 6'-9 3/8"5'-5 3/8" PRO P E R T Y L I N E PRO P E R T Y L I N E SET B A C K SET B A C K 28' HEIGHT LIMIT 2A5.1 1A5.1345 17'-11 7/8"8'-1 3/8"6'-7 1/4"15'-0 3/4" JON & KAREN JAFFE220 E. HOPKINS AVENUE MONARCHSTREET PROPOSED GRADE BEYOND -RE: CIVIL 23' - 1 0 1 / 2 " 27' - 1 1 / 2 " TRASH & RECYCLE TRASH & RECYCLE 2/103 3/103 1/107125 126 220 221 222 223 T.O. PLYLEVEL ONE100'-0" T.O. PLYLEVEL TWO111'-1 3/8" T.O. CONC.BASEMENT88'-10 5/8" 11'- 1 3 / 8 " 11'- 1 3 / 8 " 11'- 8 " T.O. PARAPET126'-7" 3'-9 5 / 8 " GENERAL NOTES: 1.EXISTING & RENOVATED PORTIONS OF ELEVATIONSARE DERIVED FROM FIELD OBSERVATION ANDEXISTING DRAWINGS. G.C. IS RESPONSIBLE FOR FIELDVERIFYING AND CONFIRMING ALL CRITICAL EXISTINGCONDITIONS AND DIMENSIONS, TYP. 2.G.C. TO PROVIDE MOCK-UP OF EACH EXTERIORMATERIAL FOR OWNER AND ARCHITECT APPROVAL,TYP. MATERIALS KEY: SIDING 1:PAINTED WOOD SHIPLAP SIDING ATTACHED ASRAINSCREEN. 6" NOM. EXPOSURE, TYP. TRIM 1:PAINTED FLAT TRIM BOARDS TO MATCH SIDING 1 CMU 1:EXISTING EXPOSED CMU BLOCK - PAINTED STANDING SEAM 1:STANDING SEAM METAL ROOFING OR SIDING, 12" O.C.SEAMS, TYP. METAL 1:HEAVY-GAUGE PRE-FINISHED METAL TO MATCH ROOFINGCOLOR/MATERIAL METAL 2:COR-TEN STEEL RAINSCREEN CLADDING. 4" NOM.EXPOSURE, TYP. MASONRY 1:BRICK VENEER MASONRY - RE: ARCHITECT FOR COLORSELECTION WINDOWS:METAL CLAD WOOD WINDOWS - RE: SCHEDULE FOR SPECIFICATIONS & COLOR DOORS:METAL CLAD WOOD DOORS - RE: SCHEDULE FOR SPECIFICATIONS & COLOR STAIR COREBEYOND METAL 1MASONRY 1 STANDING SEAM 1 METAL 1 METAL CAP TOMATCHWINDOWSYSTEM SIDING 1 METAL 2 METAL 2 METAL CAPTO MATCHWINDOWSYSTEM SIDING 1 METAL 1SIDING 1 METAL 2 T.O. PLYROOF122'-9 3/8" GRADE AT PROPERTYLINE - RE: CIVIL PROPOSED GRADE BEYOND -RE: CIVIL GRADE AT PROPERTY LINE - RE:CIVIL 220 220 223 223 WHy1'-6 " ELEC.METERBANK MDP CONCRETE CURB GARAGE SLAB99'-6"T.O. PLYLEVEL ONE ADU99'-6" PROPOSED F B A 100'-0" 65'-5 3/8"10'-5 1/4" SET B A C K SET B A C K PRO P E R T Y L I N E PRO P E R T Y L I N E 28' HEIGHT LIMIT 1A5.22A5.2 CDEG 24'-1 3/8" ALLEY HOPKINSAVENUE STEEL SLATGUARDRAIL 27' - 1 1 / 2 " 26'- 8 1 / 2 " 11'- 5 3 / 4 " ELEVATOR OVERRUN TRASH & RECYCLE 2/104 224 225 226 T.O. ROOFDECK121'-11 3/8" T.O. PLYLEVEL ONE100'-0" T.O. PLYLEVEL TWO111'-1 3/8" T.O. PLYROOF121'-3 3/8" 11' - 1 3 / 8 " 10'- 2 " T.O. PARAPET126'-7" 5'-3 5 / 8 " 28' HEIGHT LIMIT STAIR OVERRUN METAL 1 METAL 2 SIDING 1 METAL 1 SIDING 1 METAL 1 LINE OF RIDGE BEYOND STANDING SEAM 1 SIDING 1 CMU 1 METAL 1 METAL 2 GRADE - RE: CIVIL GRADE AT SIDEWALK -RE: CIVILUTILITY METERS -1.d w g Revision: Issue: SHEET TITLE PROJECT NO: DWG FILE: 21718_A4-1.dwg MTN FORG RENOVATIO AND ADDIT 230-234 E. HOP ASPEN, CO 816 21718 11.16.2017P+Z FINAL HEARING 234 e hopkins aveaspen, co 81611970.544.9006 o970.544.3473 f rowland+barchitecture / urban d 11.21.2017FURNITURE PLAN O 12.06.2017COORDINATION 05.16.2018COORDINATION 06.01.2018REVIEW 07.12.2018COORDINATION 08.02.2018CONSTRUCTION DO PROPOSE EXTERIOR Provide a diagram ofthe north elevationdemonstratingcompliance with 2015IBC 705.8. Be sure tomeasure each floorseparately. JON & KAREN 220 E. HOPKINS T.O. PLYLEVEL ONE (E) 100'-0" T.O. PLYLEVEL TWO (E) 111'-1 3/8" T.O. PLY ROOF (IN FOREGROUND) 121'-3 3/8" 11 ' - 1 3 / 8 " 3/ 8 " 10 ' - 2 " T.O. PLATE AT GABLE 122'-6" T.O. PARAPET(IN FOREGROUND) 126'-7" 12 12 12 12 R2 A7.03 F2 A7.02 F6 A7.02 W17F A7.02 EXIST. CMU WALLS EXIST. FOUNDATION RESIDENCE DINING 203 COMM. UNIT 2A 108 SE T B PR O P E R T Y EXIST. SETBACK ENCROACHMENT R1 A7.03 W3 A7.02 SIM. F4 A7.02 The dwelling separation needs to be continuous. Either make R2 1 hour fire rated or detail another method for keeping a fire from spreading in the direction of the arrow I've drawn. 2015 IBC 708, 711. SCALE: PROPOSEDBUILDING SECTION 3/16" = 1'-0" 1 A5.2 JON & KAREN JAFFE220 E. HOPKINS AVENUE T.O. PLYLEVEL ONE (E)100'-0" T.O. PLYLEVEL TWO (E)111'-1 3/8" T.O. CONC.BASEMENT (E)88'-10 5/8" T.O. PLYROOF (IN FOREGROUND)121'-3 3/8" 11' - 1 3 / 8 " 11'- 1 3 / 8 " 10 ' - 2 " T.O. PLATEAT GABLE122'-6" T.O. PARAPET(IN FOREGROUND)126'-7" 1 2 3 4 5 6 7 60'-0" 5'-5 3/8"15'-0 3/4"6'-7 1/4"8'-1 3/8"17'-11 1/4"6'-10" 1A5.12A5.1 12 12 12 12 R2A7.03F2A7.02 MONARCHSTREET F2A7.02 F6A7.02F6A7.02 F2A7.02F2A7.02 5A7.10 SIM. O.H. W5A7.01 W17FA7.02 EXIST. CMU WALLS EXIST. FOUNDATION F8A7.02 F1A7.02 F1A7.02 RESIDENCEGREAT RM 204 RESIDENCEDINING 203 COMM.UNIT 1100 ENTRYLOBBY109 COMM.UNIT 2A108 SE T B A C K PR O P E R T Y L I N E PR O P E R T Y L I N E SE T B A C K EXIST. SETBACKENCROACHMENT R1A7.03 R1A7.03 COMM.UNIT 6 016 COMM.UNIT 4 001 COURTYARD000 LINE OF PROPOSEDGRADE - RE: CIVIL GUARDRAIL BEYOND 2A7.10 W3A7.02 SIM. F4A7.02 SCALE: PROPOSEDBUILDING SECTION 3/16" = 1'-0" 2 A5.2 JON & KAREN JAFFE 220 E. HOPKINS AVENUE 5'-3 5 / 8 " T.O. PLYLEVEL ONE100'-0" T.O. PLYLEVEL TWO111'-1 3/8" T.O. CONC.BASEMENT88'-10 5/8" T.O. PLYROOF121'-3 3/8" 11' - 1 3 / 8 " 11' - 1 3 / 8 " 10'- 2 " T.O. ROOFDECK "A"121'-11 3/8" T.O. PARAPET126'-7" 1 2 3 4 5 6 7 60'-0" 5'-5 3/8"15'-0 3/4"6'-7 1/4"8'-1 3/8"17'-11 1/4"6'-10" 1A5.1 2A5.1 EXIST. CMU WALLS NEWEGRESSWELL PARAPET ROOF BEYOND ROOF BEYONDPARAPET EXIST. BEAMBEYONDBEAM - RE:STRUCT. EXIST. FOUNDATION EXIST. ROOFFRAMING EXIST. AREAWELLWALL - TOP CUTDOWN BELOWGRADE NEW EGRESS WELLWALL F1A7.02 8'-8 " R3A7.03 R2A7.03F2A7.02 F2A7.02 EXIST. BEAMBEYOND 8'- 1 0 " 8'-0 " RES.BATH 210 HALL 208 RESIDENCECLOSET 211 CORR. 2 216 STORAGE 214 COMM.UNIT 1 100 HALL 105 COMM.UNIT 2B 107RAISED PLANTER &WATER QUALITYCAPTURE - RE:LANDSCAPE & CIVIL F2A7.02 W4A7.01 COMM. 1BATHROOM 101 BEDROOM 002 COMM.UNIT 5007 W6 A7.01 BEAM - RE:STRUCT. STORAGE012 SE T B A C K PR O P E R T Y L I N E PR O P E R T Y L I N E SE T B A C K SOIL NAIL WALL - RE:SHORING DESIGN COMM. 3CORRIDOR017 GLASS SAFETYGUARD 1'-0 " 3'-2 " GLASS SAFETYGUARD HOT TUB HOT TUB 4'- 0 " P I T PER M F R . 12' - 7 " C L R . PER M F R . 10' - 0 " M A X . O V E R R U N R4A7.03SIM. R3A7.03 T.O. CONCRETE135'-7" F2A7.02 W17F A7.02 6A7.10 BEYOND 6 A6.24 ELEVATORSHAFT ELEVATORSHAFT 9'-0 " W3A7.02 SIM. EXIST. SETBACKENCROACHMENT F4A7.02 COPYRIGHT 2018 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGNTHE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT ISTHE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBANDESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIORWRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBANDESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALLRETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,INCLUDING COPYRIGHT THERETO. Revision: Issue: SHEET TITLE PROJECT NO: DWG FILE: SCALE: 21718_A5-1.dwg MTN FORGE RENOVATION AND ADDITION 230-234 E. HOPKINS AVENUE ASPEN, CO 81611 21718 11.16.2017P+Z FINAL HEARING 1830 blake st, ste 200denver, co 80202303.308.1373 o303.308.1375 f 234 e hopkins aveaspen, co 81611970.544.9006 o970.544.3473 f rowland+broughtonarchitecture / urban design / interior design 11.21.2017FURNITURE PLAN OPTIONS 12.06.2017COORDINATION 05.16.2018COORDINATION 06.01.2018REVIEW 07.12.2018COORDINATION 08.02.2018CONSTRUCTION DOCUMENTS A5.2 3/16" = 1'-0" PROPOSEDBUILDINGSECTIONS Provide parapets at all exterior wallsrequired to be rated due to proximity toproperty line (or demonstrate how youmeet one of the exceptions). 2015IBC 705.11. MONARCH STREET 1 2 3 4 5 60'-0" 15'-0 3/4"6'-7 1/4"8'-1 3/8"17'-11 1/4"6'-10" 1 A5.1 2 A5.1 NEW EGRESS WELL ROOF BEYOND PARAPET EXIST. BEAM BEYOND BEAM - RE: STRUCT. EXIST. AREAWELLWALL - TOP CUT DOWN BELOW GRADE NEW EGRESS WELLWALL F1 A7.02 8'- 8 " R3 A7.03 F2 A7.02 F2 A7.02 EXIST. BEAM BEYOND 8'- 1 0 " 8'- 0 " RES.BATH 210 HALL 208 RESIDENCECLOSET 211 CORR. 2 216 STORAGE 214 COMM.UNIT 1 100 HALL 105 COMM.UNIT 2B 107 RAISED PLANTER & WATER QUALITY CAPTURE - RE:LANDSCAPE & CIVIL F2 A7.02 W4 A7.01 COMM. 1BATHROOM 101 BEDROOM 002 COMM.UNIT 5 007 W6 A7.01 BEAM - RE: STRUCT. STORAGE 012 SE T B A C K PR O P E R T Y L I N E COMM. 3CORRIDOR 017 GLASS SAFETY GUARD 1'- 0 " 3'- 2 " HOT TUB HOT TUB 4'- 0 " P I T PE R M F R . 12 ' - 7 " C L R . PE R M F R . 10 ' - 0 " M A X . O V E R R U N R4 A7.03 SIM. R3 A7.03 F2 A7.02 6 A7.10 BEYOND 6 A6.24 ELEVATORSHAFT ELEVATORSHAFT This wall is a dwelling separation wall. This makes it a fire partition which must extend to the underside the roof sheathing without interruption by structure OR to the underside of a 1 hour fire rated horizontal assembly ceiling. Also, please provide a callout for the wall assembly type. 2015 IBC 708.4. Page: A6.21 ENLARGED PLANS MAIN STAIR File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Provide a barrier at the level of exit discharge per 2015 IBC 1023.8. Page: A6.21 ENLARGED PLANS MAIN STAIR File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Where handrails are not continuous between flights, the handrails must extend horizontally not less than 12 inches beyond the top riser and continue to slope for the depth of one tread beyond the bottom riser. Landings may not be encroached on so you may need to increase the size of the stair enclosure. 2015 IBC 1014.6 Page: A6.22 SECTION AT MAIN STAIR File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Provide riser heights. 2015 IBC 1011.5. Page: A6.23 COURTYARD STAIR DRAWINGS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Provide riser heights. 2015 IBC 1011.5. Page: A6.24 AHU STAIR DRAWINGS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Provide riser heights. 2015 IBC 1011.5. S 1 A6.22 65 7 F T. O. PLY. 100'-0" T. O. FINISH 100'-0 3/4" T. O. FINISH 100'-0 3/4" T. O. FINISH100'-0 3/4" SL O P E D N PE R C I V I L STAIR #1 104 DN UP 1'-0"1'-0" 3'-6"9 T@11" = 8'-3" 3'- 6 " 4" 3'- 6 " 3'-6" 1'-0" 3'-2" 7'- 5 3 / 4 " 15'-3" TRUE NORTH PLAN NORTH SLOPE DN PER CIVIL Provide a barrier at the level of exit discharge per 2015 IBC 1023.8. S SCALE: STAIR #1 - ENLARGED PLAN - BASEMENT LEVEL 1/2" = 1'-0" 1 A6.21 SCALE: STAIR #1 - ENLARGED PLAN - LEVEL ONE 1/2" = 1'-0" 2 A6.21 1 A6.22 1A6.22 65 7 65 F F T. O. PLY.100'-0"T. O. FINISH100'-0 3/4" T. O. FINISH100'-0 3/4" T. O. FINISH100'-0 3/4" SLO P E D N PE R C I V I L T. O. SLAB88'-10 5/8"T. O. FINISH88'-11 3/8" STAIR #1010 STAIR #1 104 DN UP UP 1'-0"1'-0" 3'-6"9 T@11" = 8'-3" 3'- 6 " 4" 3'-6 " 3'-6" 1'-0" 3'-2" 1'-0" 3'-6 " 5 3 / 4 " 3'-6 " 9 T@11" = 8'-3"3'-6"3'-6" 7'-5 3 / 4 " 7'-5 3 / 4 " 15'-3" 15'-3" TRUENORTHPLANNORTH TRUE NORTH PLAN NORTH SLOPE DN PER CIVIL File P a t h : P : \ P r o j - 2 0 1 7 \ 2 1 7 1 8 . 0 0 _ M t n F o r g e \ 0 6 _ D o c u m e n t a t i o n \ 0 1 _ D r a w i n g s \ 2 1 7 1 8 _ A 6 - 2 1 . d w g Plot D a t e / T i m e : A u g u s t 0 1 , 2 0 1 8 - 2 : 3 9 p m Where handrails are not continuous between flights, thehandrails must extend horizontally not less than 12inches beyond the top riser and continue to slope for the depth of one tread beyond the bottom riser. Landings may not be encroached on so you may need to increase the size of the stair enclosure. 2015 IBC 1014.6 5'- 3 5 / 8 " T.O. PLYLEVEL TWO (E) 111'-1 3/8" T.O. PLYROOF (E)121'-3 3/8" 11 ' - 1 3 / 8 " 10 ' - 2 " T.O. ROOFDECK "A" & LANDING 121'-11 3/8" T.O. PARAPET126'-7" 765 LINE OF SETBACK LINE OF SETBACK EXISTING WALL BEYOND PR O P E R T Y L I N E PR O P E R T Y L I N E (B E Y O N D LIN E O F S E T B A C K (B E Y O N D ) LINE OF SETBACK STAIR #1 104 LINE OF WALL BEYOND STAIR #1 212 6'-8 " C L R . 7'-4" CLR. 7'-4" CLR.6- 1 1 / 1 6 " = 5 ' - 6 1 1 / 1 6 " 10 R @ 6 - 1 1 / 1 6 " = 5 ' - 6 1 1 / 1 6 " 7'-4" CLR. 6'-8" C L R . 7'-4" CLR. 6'-8" C L R . 7'-4" CLR. 8'- 0 1 / 4 " 9R @ 6 - 1 3 / 1 6 " = 5 ' - 1 1 / 4 " 10 R @ 6 - 1 3 / 1 6 " = 5 ' - 8 " 3'- 6 " OPAQ U E G U A R D 1-1/2" D I A . H A N D R A I L @ 3 ' - 0 " A B O V E N O S I N G OPAQ U E G U A R D 1-1/2" D I A . H A N D R A I L @ 3 ' - 0 " A B O V E N O S I N G 3'- 6 " OP A Q U E G U A R D 3'- 0 " 3'- 6 " HANDRAIL EXTENSION HANDRAIL BEYOND OP A Q U E G U A R D W-14 A7.02 STAIR #1 303 EXISTING PORTION OF BUILDING (BEYOND) - EXISTING SETBACK ENCROACHMENT Revision: Issue: MTN FORGE RENOVATION 11.16.2017P+Z FINAL HEARING 1830 bla den 30 3 234 e hopkins aveaspen, co 81611970.544.9006 o 970.544.3473 f rowland+brou architecture / urban design / in 11.21.2017 FURNITURE PLAN OPTIONS 12.06.2017 COORDINATION 05.16.2018COORDINATION 06.01.2018 REVIEW 07.12.2018COORDINATION 08.02.2018CONSTRUCTION DOCUMEN Provide riser heights. 2015 IBC 1011.5. SE T B A C K 16 R @ 6 - 7 / 8 " = 9 ' - 1 3 / 4 " 3'- 0 " H A N D R A I L 3'- 6 " G U A R D 3'- 0 " 3'- 6 " F9 A7.03 F10 A7.03 WALL BEYOND WALL BEYOND D : STEEL GUARDRAIL STEEL HANDRAIL CONCRETE WALL AT STAIR EDGE EX W NE ST SN TR 8 A7.10 Provide riser heights. 2015 IBC 1011.5. BrassFaucetsStillnessK-T948-4 SCALE: SECTION AT AHU STAIR 1/2" = 1'-0" 3 A6.24 3'- 0 " 3'- 0 " 3'- 0 " AHU 004 7R @ 7 - 1 / 2 " = 4 ' - 4 7 / 1 6 " 10 R @ 7 - 1 / 2 " = 6 ' - 2 1 5 / 1 6 " R. MECH &STORAGE 005 AHU 102 9'- 0 " 8'- 8 " 6'-8" C L R . 7'-4" CLR. 7'-4" CLR. TRUE NORTH PLAN NORTH F6 A7.02 SIM. F7 A7.02 Provide riser heights. 2015 IBC 1011.5. Page: A7.0A CODE LISTED ASSEMBLIES File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: This assembly requires carpet to achieve the listed STC. Choose another assembly to match your floor finish. Page: A7.01 BUILDING ASSEMBLIES File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Page: A7.02 BUILDING ASSEMBLIES File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Dwelling separation horizontal assemblies also require an IIC rating of 50 or greater. Demonstrate how assemblies F2 and F6 will comply. 2015 IBC 1207. Page: A7.10 DETAILS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Handrail extensions must return. 2015 IBC 1011.11. Page: A8.1 WINDOW SCHEDULE File Name: ARCHITECTURAL.PDF Subject: SHGC for windows Author: nickt Color: Windows serving common and commercial spaces that face East, South, and West must have a solar heat gain coefficient of 0.45 or less if the projection factor is less than 0.2. (2015 IECC C402.4.3) SCALE: FLOOR/CEILING ASSEMBLY 1-HOUR RATED : GA FILE NO. FC 5111 1 1/2" = 1'-0" FC5111 A7.0A This assembly requires carpet to achieve the listed STC. Choose another assembly to match your floor finish. ING WALLS) BASEMENT R10 MIN. BELOW GRADE SCALE: WALL ASSEMBLY (EXISTING WALLS) EXTERIOR CMU WALL WITH EXTERIO 1 1/2" = 1'-0" W3 A7.01 INTERIOREXTERIOR BELOW GRADE EXISTING CAST IN PLACE CONCRETE EXISTING BACKFILL 5/8" GWB 2X FURRING MINERAL WOOL CAVITY INSULATION - R-20 MIN. VIF EXIST. VARIES EXIST. EXISTING WATERPROOFING (AT BELOW GRADE WALLS) 1" CLR. GAP 3 1/2"3 1/2" 3 1/2" RE: PLAN NOTE: STUD DIMENSIONS GIVEN ARE MINIMUM. GC TO REVIEW COLUMN LAYOUTS AND ADJUST SCALE: WALL ASSEMBLY (EXISTING WALLS) FOUNDATION WALL AT BASEMENT - WITH NEW BRICK LEDGE 1 1/2" = 1'-0"R10 CI MIN. BELOW GRADE W2 A7.01 INTERIOR EXTERIOR BELOW GRADE EXISTING CAST IN PLACE CONCRETE WITH EXIST. WATERPROOFING BACKFILL PER GEOTECH VARIES EXIST. TREMCO 2 3/8" TUFF-N-DRI FLUID APPLIED MEMBRANE & WARM-N-DRI INSULATION & DRAINAGE BOARD (R-10) 4" NOM. FULLY GROUTED CMU DOWN TO EXIST. FOOTER NEW SPRAY APPLIED CLOSED-CELL FOAM - FILL CAVITY NEW 2X FURRING WALL SET OFF CONC. WALL 1/2" 5/8" GWB - RE: SCHEDULE FOR FINISH NEW SCALE: FLOOR ASSEMBLY (EXISTING FLOORS) SLAB ON GRADE 1 1/2" = 1'-0" EXISTING SOIL SCALE: FLOOR ASSEMBLY (EXISTING FLOORS) TYPICAL WOOD FRAMED FLOORS 1 1/2" = 1'-0" F2 A7.02 EXISTING FRAMING - RE: STRUCTURAL INTERIOR DROPPED CEILING - VARIES - RE: RCPS CEILING FRAMING AS REQUIREDMECH. SPACE 2-LAYERS 1/2" TYPE X GWB APPLIED PER LISTED ASSEMBLY 5/8" TYPE X GWB RA T E D A S S E GA F C 5 1 1 VA R I E S - R E : R C P S GA FC 5111 STC 50-54 1-HOUR FIRE RATED ASS'Y RESILIENT CHANNEL PER LISTED ASSEMBLY SCALE: FLOOR ASSEMBLY (NEW FLOORS) TYPICAL WOOD FRAMED FLOORS 1 1/2" = 1'-0" INTERIOR SUBFLOOR - RE: STRUCTURAL FRAMING - RE: STRUCTURAL INTERIOR DROPPED CEILING - VARIES - RE: RCPS CEILING FRAMING AS REQUIREDMECH. SPACE 2-LAYERS 1/2" TYPE X GWB APPLIED PER LISTED ASSEMBLY 5/8" TYPE X GWB FINISH FLOORING - RE: SCHEDULE GA F C 5 1 1 1 GA FC 5111 STC 50-54 1-HOUR FIRE RATED ASS'Y RESILIENT CHANNEL PER LISTED ASSEMBLY NOTE: AT "F6 SIM." OMIT RESILIENT CHANNEL AND 2-LAYERS OF TYPE X GWB FASTENED TO FLOOR/CEILING FRAMING. NO RATING REQUIRED IN THIS CONDITION. UL DESIGN NO. D799 1-HOUR FIRE RATED ASS'Y SCALE: FLOOR ASSEMBLY (NEW FLOORS) COMPOSITE DECK WITH TOPPING SLAB 1 1/2" = 1'-0" F7 A7.02 RA T E D A S S E M B L Y UL D 7 9 9 O R D 9 0 2 SPRAY APPLIED FIREPROOFING. APPLY TO THICKNESS SPECIFIED IN UL LISTING, TYP. COMPOSITE METAL AND CONCRETE DECK - RE: STRUCTURAL STEEL BEAM - RE: STRUCTURAL FLUID APPLIED WATERPROOF MEMBRANE DRAINAGE MAT CONCRETE TOPPING SLAB - SLOPE TO DRAIN PER PLAN CONCRETE FINISH - RE: SCHEDULE DROPPED CEILING - VARIES - RE: RCPS CEILING FRAMING AS REQUIREDMECH. SPACE 5/8" TYPE X GWB VA R I E S RE : R C P S SCALE: FLOOR ASSE SNOWMELTE 1 1/2" F8 A7.02 SL SCALE: FLOOR ASSE SLAB ON GRA 1 1/2" F4 A7.02 EXISTING RADON MITIGATION SYSTEM - G.C. TO VERIFY SYSTEM AND RETROFIT AS REQUIRED RE Dwelling separation horizontal assemblies also require an IIC rating of 50 or greater. Demonstrate how assemblies F2 and F6 will comply. 2015 IBC 1207. 3' - 6 " M I N . V E R I F Y G R A D E 3' - 0 " 1'-0" Revision: Handrail extensions must return. 2015 IBC 1011.11. 225 226 227 228 229 WINDOW TREA MARK WT-1 WT-2 WT-3 WT-4 WT-5 WT-6 GENERAL NOTES 1. REFER TO ELEVAT 2. TEMPERED LIGHTS 3. CONFIRM FINAL WI 4. ALL OPERABLE WIN 5. WINDOW FRAME W 6. FIELD VERIFY DIME 7. MIN U-FACTORS SH Windows serving common and commercial spaces that face East, South, and West must have a solar heat gain coefficient of 0.45 or less if the projection factor is less than 0.2. (2015 IECC C402.4.3) Page: A8.2 DOOR SCHEDULE File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Door 1/107 opens into an exit discharge egress court with a width of less than 10', requiring the door to have a 45minute fire rating. (2015 IBC 1028.4.2) Page: A8.2 DOOR SCHEDULE File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Indicate the hardware and locking arrangements for the interior exit stair enclosure. Doors must be openable from both sides without a key unless one of the exceptions is met. This includes doors 1/303 and 2/104, in addition to the other stair doors. 2015 IBC 1010.1.9.11. Page: A8.2 DOOR SCHEDULE File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Doors serving the exit enclosure stair must be 60 min fire rated (2015 IBC 716.5). Revise 1/010, 1/104, 1/217, 1/303. Page: A9.1 PROPOSED INTERIOR ELEVATIONS File Name: ARCHITECTURAL.PDF Subject: PlanCheck Author: nickt Color: Show and dimension clearspaces at each toilet and lavatory. Also show a clearspace beyond the swing of the door. ICC A117.1-2009 chapter 6. Page: 1 File Name: COMCHECK.pdf Subject: PlanCheck Author: nickt Color: Provide a lighting schedule and cutsheets for each fixture. The cutsheets should have the maximum wattage highlighted (and this should match the comcheck) and the listing by a nationally recognized testing lab highlighted. COMCHECK.pdf (6) SCALE: DOOR TYPE B 1/2" = 1'-0" 2 SCALE: DOOR TYPE C 1/2" = 1'-0" C A8.2 SCALE: DOOR TYPE D 1/2" = 1'-0" D A8.2 SCALE: DOOR TYPE F 1/2" = 1'-0" F A8.2 INTERIOR SWING - SOLID RE: SCHEDULE 3'-0 " VE R I F Y 2 3/4" SOLID COREWOOD DOOR PANEL DETAIL TBD RE: PLANSFOR SWINGORIENTATION DOORFINISH TBD INTERIOR SWING - SOLID (AHU) RE: SCHEDULE RE : S C H E D U L E 3'-0 " VE R I F Y 2 3/4" SOLID COREWOOD DOOR FLUSH PANEL RE: PLANSFOR SWINGORIENTATION PAINTEDFINISH ORE CK MOUNTTYP. INTERIOR SWING - SOLID - RATED RE: SCHEDULE RE : S C H E D U L E 3'-0 " VE R I F Y 2 3/4" SOLID CORERATED WOOD DOOR PANEL DETAIL TBD RE: PLANSFOR SWINGORIENTATION DOORFINISH TBD INTERIOR DOUBLE SWING - SOLID RE: SCHEDULE RE : S C H E D U L E 3'- 0 " VER I F Y 2 3/4" SOLID COREWOODDOOR PANELDETAIL TBD RE: PLANS FOR SWINGORIENTATION DOOR FINISH TBD 2 3/4" 10 " MIN . A D A 10 " MIN . A D A 10" MIN . A D A SCALE: DOOR TYPE G 1/2" = 1'-0" G A8.2 BUILDING ENTRY DOOR - EXTERIOR SWING - GLAZED RE: SCHEDULE RE : S C H E D U L E TEMPEREDINSULATEDGLAZING 5 1/2"5 1/2" 10" MIN . A D A ALUMINUMCLAD WOODDOOR 3'- 0 " VER I F Y 2 3/4" RE: PLANSFOR SWINGORIENTATION SCALE: DOOR TYPE J 1/2" = 1'-0" 2 INTERIOR SWING - GLAZED RE: SCHEDULE 3'-0 " VE R I F Y 2 3/4" WOODDOOR PANELDETAIL TBD DOORFINISH TBD 10 " MIN . A D A RE: PLANSFOR SWINGORIENTATION TEMPEREDGLAZING SCALE: DOOR TYPE K 1/2" = 1'-0" K A8.2 RE: SCHEDULE RE : S C H E D U L E 3'-0 " VE R I F Y 10 " MIN . A D A RE: PLANSFOR SWINGORIENTATION2 3/4"2 3/4" EXTERIOR SWING - GLAZED - CENTER MULLION ALUMINUMCLAD WOODDOOR CENTERMULLION TEMPEREDINSULATED GLAZING TEMPEREDINSULATED GLAZING SCALE: DOOR TYPE M 1/2" = 1'-0" M A8.2 EXTERIOR - SLIDING GLAZED DOORS RE: SCHEDULE RE : S C H E D U L E TEMPEREDINSULATEDGLAZING TEMPEREDINSULATEDGLAZING TEMPEREDINSULATEDGLAZING FIXED PANEL EQ EQ EQ BY M F R - V E R I F Y CL CL SCALE: DOOR TYPE N 1/2" = 1'-0" N A8.2 INTERIOR POCKET - SOLID RE: SCHEDULE RE : S C H E D U L E 3'-0 " VE R I F Y 2 3/4" SOLID COREWOODDOOR PANELDETAIL TBD RE: PLANS FORPOCKETORIENTATION DOORFINISH TBD 10" MIN . A D A VERIFY BACKSET W/POCKETDOORHARDWARE GC TO COORDINATE LEAFEXTENSION ON POCKET SIDE MOUNTAIN FORGE APPENDIX - BRB PROJ # 21718 234 E HOPKINS AVE ASPEN, CO 81611 DOOR SCHEDULE07.26.2018 Revised xxxx.xx.xx DOOR MARK QTY.DOOR WIDTH DOORHEIGHT DOORTHICKNESS DOOR TYPE FRAMETYPE DETAILS HDWR GRP GLASS TYPE FIRERATING NOTES BASEMENT LEVEL 1/001 1 3'-0"6'-8" VIF 1-3/4"A VIF SIZE - EXISTING OPENINGCOORDINATE WITH WINDOWS016 &017 1/002 1 2'-4"7'-0"1-3/4"C 2/002 2 EQ.5-0" TOTAL 7'-0"1-3/4"E CLOSET DOORS 1/003 1 2'-4"7'-0"1-3/4"C 2/003 2 EQ.5-0" TOTAL 7'-0"1-3/4"E CLOSET DOORS 1/005 1 2'-6"VARIES 1-3/4"C VIF HEAD CONDITION W/ STAIR 1/006 1 2'-2"7'-0"1-3/4"C 1/007 1 3'-0"7'-0"1-3/4"N 1/008 1 3'-0"7'-0"1-3/4"D 20 MIN.MECH ROOM DOOR 1/009 1 2'-8"7'-0"1-3/4"B 1/010 1 3'-0"7'-0"1-3/4"D 20 MIN.STAIR DOOR 1/011 1 3'-0"7'-0"1-3/4"D 20 MIN.ELEV. MACHINE RM. DOOR 1/012 1 3'-0"7'-0" 1-3/4"B 1/014 1 3'-0"7'-0" 1-3/4"B 1/015 1 3'-0"7'-0"1-3/4"B 1/016 1 3'-0"6'-8" VIF 1-3/4"A VIF SIZE - EXISTING OPENINGCOORDINATE WITH WINDOW 001 2/017 1 3'-0"7'-0"1-3/4"B LEVEL ONE 1/100 1 3'-0"7'-0"BY MFR G VIF SIZE - EXISTING OPENINGCOORDINATE WITH WINDOW 114 2/100 1 3'-0"7'-0"1-3/4"B NEW DOOR IN EXIST OPENING -VIF 1/101 1 EXIST EXIST EXIST N/A EXISTING TO REMAIN 1/102 1 3'-0"7'-0"BY MFR G COORDINATE WITH WINDOW 123 1/103 1 3'-0"7'-0"1-3/4"D 20 MIN.GARAGE ENTRY 2/103 1 8'-0"8'-6"BY MFR L GARAGE OVERHEAD DOOR 3/103 1 8'-0"8'-6"BY MFR L GARAGE OVERHEAD DOOR 1/104 1 3'-0"7'-0"1-3/4"D 20 MIN.STAIR DOOR 2/104 1 3'-0"7'-0"1-3/4"H STAIR DOOR 1/106 1 3'-0"7'-0"1-3/4"B 1/107 1 3'-0"7'-0"1-3/4"H 2/107 1 3'-0"7'-0"1-3/4"J 1/108 1 3'-0"7'-0"1-3/4"J 2/108 2 3'-0"7'-0"BY MFR K CENTER MULLION- COORDINATEWITH WINDOW 101 1/109 1 3'-0"7'-0"BY MFR G COORDINATE WITH WINDOW 103 LEVEL TWO 1/201 1 3'-6"7'-0"1-3/4"D 20 MIN. 1/203 3 EQ.OVERALL 13'-6" TOTAL 10'-6"BY MFR M SLIDING DOORS - OXX - SEEELEVATION - ALIGNS WITH WDW201 ABOVE 1/207 1 3'-6"7'-0"1-3/4"N 1/208 1 3'-0"7'-0"1-3/4"B 1/209 1 2'-8"7'-0"1-3/4"B 1/210 1 2'-8"7'-0"1-3/4"B 1/211 1 2'-8"7'-0"1-3/4"B 1/213 1 2'-6"7'-0"1-3/4"B 1/214 1 2'-10"7'-0"1-3/4"B 1/215 1 3'-0"7'-0"1-3/4"B 1/217 1 3'-0"7'-0"1-3/4"D 20 MIN.STAIR DOOR 1/218 1 3'-0"7'-0"1-3/4"D 20 MIN.MECH ROOM DOOR 1/219 1 3'-6 3/4"7'-0"BY MFR A COORDINATE WITH WINDOWS217 ABOVE AND 219 RE:ELEVATIONS 2/219 1 3'-0"7'-0"1-3/4"B 3/219 1 3'-0"7'-0"1-3/4"B 1/220 1 2'-8"7'-0"1-3/4"B 1/221 1 3'-0"7'-0"1-3/4"B 20 MIN. 1/222 1 2'-8"7'-0"1-3/4"B ROOF LEVEL 1/303 1 3'-0"7'-0"1-3/4"D 20 MIN.STAIR DOOR GENERAL NOTES 1. REFER TO ELEVATIONS FOR ALL ALIGNMENTS. 2. RE: DOOR AND FRAME ELEVATION FOR DOOR AND FRAME TYPES. 3. CONFIRM FINAL DOOR SIZES WITH DOOR MANUFACTURER. ROUGH OPENING SIZE BY MANUFACTURER AND ARE NOT LISTED ON THIS SCHEDULE. 4. HARDWARE GROUPS ARE AS FOLLOWS (NOTE, DOORS DENOTED WITH AN [R] FOLLOWING THE DESIGNATION INDICATES A RESIDENTIAL GROUP OF THE SAME APPLICATION): A = EXTERIOR SWING LOCKSET; B = INTERIOR SWING LOCKSET; C = INTERIOR SWING PASSAGE; D - INTERIOR POCKET LOCKSET; E =INTERIOR POCKET PASSAGE; F = INTERIOR SWING PASSAGE - SEALED; G = INTERIOR SWING JIB; H - ELEVATOR SWING INTERLOCK; I - INTERIOR SWING FRAMELESS 5. ALL EXTERIOR DOORS TO RECEIVE ACCESS CONTROL SYSTEM, U.N.O. ACCESS CONTROL SYSTEM SHALL BE APP-ENABLED. 6. ALL ENTRANCE DOORS FOR COMMERCIAL SPACES SHALL HAVE A U-FACTOR OF .77 PER IECC TABLE C402.4. COPYRIGHT 2018 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGNTHE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT ISTHE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBANDESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR Revision: Issue: SHEET TITLE PROJECT NO: DWG FILE: SCALE: 21718_A8-1.dwg MTN FORGE RENOVATION AND ADDITION 230-234 E. HOPKINS AVENUE ASPEN, CO 81611 21718 11.16.2017P+Z FINAL HEARING 1830 blake st, ste 200denver, co 80202303.308.1373 o303.308.1375 f 234 e hopkins aveaspen, co 81611970.544.9006 o970.544.3473 f rowland+broughtonarchitecture / urban design / interior design 11.21.2017FURNITURE PLAN OPTIONS 12.06.2017COORDINATION 05.16.2018COORDINATION 06.01.2018REVIEW 07.12.2018COORDINATION 08.02.2018CONSTRUCTION DOCUMENTS DOORSCHEDULE AS NOTED A8.2 Door 1/107 opens into an exit dischargeegress court with a width of less than 10',requiring the door to have a 45minute firerating. (2015 IBC 1028.4.2) X - B DULE DETAILS HDWR GRP GLASS TYPE FIRE RATING NOTES VIF SIZE - EXISTING OPENING COORDINATE WITH WINDOWS 016 &017 CLOSET DOORS CLOSET DOORS VIF HEAD CONDITION W/ STAIR Indicate the hardware and locking arrangements for the interior exit stair enclosure. Doors must be openable from both sides without a key unless one of the exceptions is met. This includes doors 1/303 and 2/104, in addition to the other stair doors. 2015 IBC 1010.1.9.11. SCALE: DOOR TYPE D 1/2" = 1'-0" D A8.2 ORE NSNGATION INTERIOR SWING - SOLID - RATED RE: SCHEDULE RE : S C H E D U L E 3'-0 " VE R I F Y 2 3/4" SOLID CORE RATED WOOD DOOR PANELDETAIL TBD RE: PLANSFOR SWINGORIENTATION DOORFINISH TBD 10" MIN . A D A SCALE: DOOR TYPE G 1/2" = 1'-0" G A8.2 BUILDING ENTRY DOOR - EXTERIOR SWING - GLAZED RE: SCHEDULE RE : S C H E D U L E TEMPEREDINSULATEDGLAZING 5 1/2"5 1/2" 10 " MIN . A D A ALUMINUMCLAD WOODDOOR 3'- 0 " VE R I F Y 2 3/4" RE: PLANS FOR SWING ORIENTATION EDULE VE R I F Y 10" MIN . A D A RE: PLANSFOR SWINGORIENTATION ER MULLION ALUMINUMCLAD WOODDOOR CENTERMULLION EREDATEDNG TEMPEREDINSULATEDGLAZING EQ MFR - V E R I F Y RE: SCHEDULE RE: S C H E D U L E 3'-0 " VE R I F Y 2 3/4" SOLID COREWOODDOOR PANELDETAIL TBD RE: PLANS FORPOCKETORIENTATION DOORFINISH TBD VERIFYBACKSET W/POCKETDOORHARDWARE GC TO COORDINATE LEAFEXTENSION ON POCKET SIDE MOUNTAIN FORGE APPENDIX - BRB PROJ # 21718 234 E HOPKINS AVE ASPEN, CO 81611 DOOR SCHEDULE07.26.2018 Revised xxxx.xx.xx DOOR MARK QTY.DOOR WIDTH DOOR HEIGHT DOOR THICKNESS DOOR TYPE FRAME TYPE DETAILS HDWR GRP GLASS TYPE FIRE RATING NOTES BASEMENT LEVEL 1/001 1 3'-0"6'-8" VIF 1-3/4"A VIF SIZE - EXISTING OPENINGCOORDINATE WITH WINDOWS016 &017 1/002 1 2'-4"7'-0"1-3/4"C 2/002 2 EQ.5-0" TOTAL 7'-0"1-3/4"E CLOSET DOORS 1/003 1 2'-4"7'-0"1-3/4"C 2/003 2 EQ.5-0" TOTAL 7'-0"1-3/4"E CLOSET DOORS 1/005 1 2'-6"VARIES 1-3/4"C VIF HEAD CONDITION W/ STAIR 1/006 1 2'-2"7'-0"1-3/4"C 1/007 1 3'-0"7'-0"1-3/4"N 1/008 1 3'-0"7'-0"1-3/4"D 20 MIN.MECH ROOM DOOR 1/009 1 2'-8"7'-0"1-3/4"B 1/010 1 3'-0"7'-0"1-3/4"D 20 MIN.STAIR DOOR 1/011 1 3'-0"7'-0"1-3/4"D 20 MIN.ELEV. MACHINE RM. DOOR 1/012 1 3'-0"7'-0" 1-3/4"B 1/014 1 3'-0"7'-0" 1-3/4"B 1/015 1 3'-0"7'-0"1-3/4"B 1/016 1 3'-0"6'-8" VIF 1-3/4"A VIF SIZE - EXISTING OPENINGCOORDINATE WITH WINDOW 001 2/017 1 3'-0"7'-0"1-3/4"B LEVEL ONE 1/100 1 3'-0"7'-0"BY MFR G VIF SIZE - EXISTING OPENINGCOORDINATE WITH WINDOW 114 2/100 1 3'-0"7'-0"1-3/4"B NEW DOOR IN EXIST OPENING -VIF 1/101 1 EXIST EXIST EXIST N/A EXISTING TO REMAIN 1/102 1 3'-0"7'-0"BY MFR G COORDINATE WITH WINDOW 123 1/103 1 3'-0"7'-0"1-3/4"D 20 MIN.GARAGE ENTRY 2/103 1 8'-0"8'-6"BY MFR L GARAGE OVERHEAD DOOR 3/103 1 8'-0"8'-6"BY MFR L GARAGE OVERHEAD DOOR 1/104 1 3'-0"7'-0"1-3/4"D 20 MIN.STAIR DOOR 2/104 1 3'-0"7'-0"1-3/4"H STAIR DOOR 1/106 1 3'-0"7'-0"1-3/4"B 1/107 1 3'-0"7'-0"1-3/4"H 2/107 1 3'-0"7'-0"1-3/4"J 1/108 1 3'-0"7'-0"1-3/4"J 2/108 2 3'-0"7'-0"BY MFR K CENTER MULLION- COORDINATEWITH WINDOW 101 1/109 1 3'-0"7'-0"BY MFR G COORDINATE WITH WINDOW 103 LEVEL TWO 1/201 1 3'-6"7'-0"1-3/4"D 20 MIN. 1/203 3 EQ.OVERALL 13'-6" TOTAL 10'-6"BY MFR M SLIDING DOORS - OXX - SEEELEVATION - ALIGNS WITH WDW201 ABOVE 1/207 1 3'-6"7'-0"1-3/4"N 1/208 1 3'-0"7'-0"1-3/4"B 1/209 1 2'-8"7'-0"1-3/4"B 1/210 1 2'-8"7'-0"1-3/4"B 1/211 1 2'-8"7'-0"1-3/4"B 1/213 1 2'-6"7'-0"1-3/4"B 1/214 1 2'-10"7'-0"1-3/4"B 1/215 1 3'-0"7'-0"1-3/4"B 1/217 1 3'-0"7'-0"1-3/4"D 20 MIN.STAIR DOOR 1/218 1 3'-0"7'-0"1-3/4"D 20 MIN.MECH ROOM DOOR 1/219 1 3'-6 3/4"7'-0"BY MFR A COORDINATE WITH WINDOWS217 ABOVE AND 219 RE:ELEVATIONS 2/219 1 3'-0"7'-0"1-3/4"B 3/219 1 3'-0"7'-0"1-3/4"B 1/220 1 2'-8"7'-0"1-3/4"B 1/221 1 3'-0"7'-0"1-3/4"B 20 MIN. 1/222 1 2'-8"7'-0"1-3/4"B ROOF LEVEL 1/303 1 3'-0"7'-0"1-3/4"D 20 MIN.STAIR DOOR GENERAL NOTES 1. REFER TO ELEVATIONS FOR ALL ALIGNMENTS. 2. RE: DOOR AND FRAME ELEVATION FOR DOOR AND FRAME TYPES. 3. CONFIRM FINAL DOOR SIZES WITH DOOR MANUFACTURER. ROUGH OPENING SIZE BY MANUFACTURER AND ARE NOT LISTED ON THIS SCHEDULE. 4. HARDWARE GROUPS ARE AS FOLLOWS (NOTE, DOORS DENOTED WITH AN [R] FOLLOWING THE DESIGNATION INDICATES A RESIDENTIAL GROUP OF THE SAME APPLICATION): A = EXTERIOR SWING LOCKSET; B = INTERIOR SWING LOCKSET; C = INTERIOR SWING PASSAGE; D - INTERIOR POCKET LOCKSET; E =INTERIOR POCKET PASSAGE; F = INTERIOR SWING PASSAGE - SEALED; G = INTERIOR SWING JIB; H - ELEVATOR SWING INTERLOCK; I - INTERIOR SWING FRAMELESS 5. ALL EXTERIOR DOORS TO RECEIVE ACCESS CONTROL SYSTEM, U.N.O. ACCESS CONTROL SYSTEM SHALL BE APP-ENABLED. 6. ALL ENTRANCE DOORS FOR COMMERCIAL SPACES SHALL HAVE A U-FACTOR OF .77 PER IECC TABLE C402.4. Revision: Issue: SHEET TITLE PROJECT NO: DWG FILE: 21718_A8-1.dwg MTN FORGE RENOVATION AND ADDITION 230-234 E. HOPKINS AVENUE ASPEN, CO 81611 21718 11.16.2017P+Z FINAL HEARING 1830 blake st, ste 200denver, co 80202303.308.1373 o303.308.1375 f 234 e hopkins aveaspen, co 81611970.544.9006 o970.544.3473 f rowland+broughtonarchitecture / urban design / interior design 11.21.2017FURNITURE PLAN OPTIONS 12.06.2017COORDINATION 05.16.2018COORDINATION 06.01.2018REVIEW 07.12.2018COORDINATION 08.02.2018CONSTRUCTION DOCUMENTS DOORSCHEDULE Doors serving the exit enclosure stair mustbe 60 min fire rated(2015 IBC 716.5). Revise 1/010, 1/104,1/217, 1/303. SCALE: KEY PLAN 1/2" = 1'-0" C A9.1 2 3 4 1 A9.1 SCALE: RESTROOM 014 1/2" = 1'-0" 3 A9.1 SCALE: RESTROOM 014 1/2" = 1'-0" 4 A9.1 1'-0"2'-0" 1'-6" 2'-1 0 " MATERIALPRODUCTTRADENAMEMODELNUMBER MODELNUMBERTRADENAMEPRODUCTMATERIAL 1'-10"5'-0" 4'-6 " 2'-1 0 " 6" OOM 012 1/2" = 1'-0" KNEE AND TOE CLEARANCE INCOMPLIANCE WITH ANSI 117.1-2009SECTION 306 3'-4" 2'-1 0 " 3'-6" 3'-4 "4'-4" 1'-6 " 10" 2'-8 1/4" SCALE: RESTROOM 012 1/2" = 1'-0" 7 A9.1 1'-0"2'-0" 1'-6" 2'-1 0 " SCALE: RESTROOM 012 1/2" = 1'-0" 8 A9.1 SCALE: KEY PLAN 1/2" = 1'-0" A A9.1 1 2 3 4 A9.1 Ø5' - 0 " 7 6 5 8 A9.1 SCALE: KEY PLAN 1/2" = 1'-0" B A9.1 Ø5 ' - 0 " SCALE: RESTROOM 106 1/2" = 1'-0" 11 A9.1 SCALE: RESTROOM 106 1/2" = 1'-0" 12 A9.1 Ø5'- 0 " MODELNUMBERTRADENAMEPRODUCTMATERIAL KNEE AND TOE CLEARANCE INCOMPLIANCE WITH ANSI 117.1 GFCI 1'-10" 6" MATERIALPRODUCTTRADENAMEMODELNUMBER MODELNUMBERTRADENAMEPRODUCTMATERIAL 5'-3 1/2" 4'-6 " 2'-1 0 " 6" DOOR CLEARANCE PER ANSI117.1 SECTION 404.2.3.2 (B) GFCI 2'-3 " 7" 6" 3'-4 " MATERIALPRODUCTTRADENAMEMODELNUMBER ANSI COMPLIANT SINKAND FAUCET 36" ANSI COMPLIANT HORIZONTALGRAB BARANSI COMPLIANT TOILET RESTROOM 014 RESTROOM012 RESTROOM 106 1'-0"3'-0" 1'-6" PER ANSI 117.1SECTION 404.2.3.2 -MANEUVERINGCLEARANCE FOR PUSHAPPROACH FROMHINGE SIDE, 42" PERPTO DOOR; DOOR + 22"PARALLEL 3'-6" 5'-0 " PER ANSI 117.1SECTION 404.2.3.2 -MANEUVERINGCLEARANCE FOR PUSHAPPROACH FROMHINGE SIDE, 42" PERPTO DOOR; DOOR + 22"PARALLEL 3'-6" 5'-0 " 18" ANSI COMPLIANTVERTICAL GRAB BAR 42" ANSI COMPLIANTHORIZONTAL GRAB BAR HATCHED AREA INDICATES ANSICOMPLIANT REASON FORPROTRUDING DISPENSER BELOWGRAB BAR 36" ANSI COMPLIANT HORIZONTALGRAB BARANSI COMPLIANT TOILET 18" ANSI COMPLIANTVERTICAL GRAB BAR 42" ANSI COMPLIANTHORIZONTAL GRAB BARHATCHED AREA INDICATES ANSICOMPLIANT REASON FORPROTRUDING DISPENSER BELOWGRAB BAR ANSI COMPLIANT SINKAND FAUCET UNDER-COUNTERTRASH A9.1 1/2"=1'-0" PROPOSEDINTERIORELEVATIONS COPYRIGHT 2018 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGNTHE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT ISTHE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBANDESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIORWRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBANDESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALLRETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,INCLUDING COPYRIGHT THERETO. Revision: Issue: SHEET TITLE PROJECT NO: DWG FILE: SCALE: 21718_A9-1.dwg MTN FORGE RENOVATION AND ADDITION 230-234 E. HOPKINS AVENUE ASPEN, CO 81611 21718 11.16.2017P+Z FINAL HEARING 1830 blake st, ste 200denver, co 80202303.308.1373 o303.308.1375 f 234 e hopkins aveaspen, co 81611970.544.9006 o970.544.3473 f rowland+broughtonarchitecture / urban design / interior design 11.21.2017FURNITURE PLAN OPTIONS 12.06.2017COORDINATION 05.16.2018COORDINATION 06.01.2018REVIEW 07.12.2018COORDINATION 08.02.2018CONSTRUCTION DOCUMENTS Show and dimensionclearspaces at each toiletand lavatory. Also showa clearspace beyond theswing of the door. ICCA117.1-2009 chapter 6. ghting alteration project represented in this document is consistent with the ions submitted with this permit application. The proposed interior lighting 2013) Standard requirements in COMcheck Version 4.0.8.0 and to comply with the Inspection Checklist. Signature Date ountain Forge Building Renovation & \MOUNTAIN FORGE LTG COMCHECK.cck 07/30/18Report date: 71 ofPage 7/30/18 Provide a lighting schedule and cutsheets for each fixture. The cutsheets should have the maximum wattage highlighted (and this should match the comcheck) and the listing by a nationally recognized testing lab highlighted. Page: 1 File Name: COMCHECK.pdf Subject: PlanCheck Author: nickt Color: Include the S2 and S6 fixtures from the common restrooms. Page: 1 File Name: COMCHECK.pdf Subject: PlanCheck Author: nickt Color: Provide a lighting comcheck for the commercial units. Page: 1 File Name: COMCHECK.pdf Subject: PlanCheck Author: nickt Color: I count 51 R3 and R4 fixtures in the common areas. Revise comcheck. Page: 2 File Name: COMCHECK.pdf Subject: PlanCheck Author: nickt Color: I count 11 EX3 fixtures. Revise comcheck. Page: 2 File Name: COMCHECK.pdf Subject: PlanCheck Author: nickt Color: I count 4 EX4 fixtures. Revise comcheck. Proposed Interior Lighting Power D Fixtu Wa A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures COMMON AREAS ( Common Space Types:Corridor/Transition <8 ft wide 2060 sq.ft.) LED 1: R3 & R4: DOWNLIGHT: Other:1 53 1 LED 2: P2: PENDENT AT BATHROOM: Other:1 2 1 LED 3: P3: PENDENT AT BATHROOM: Other:1 2 1 LED 4: F2: LED STRIP AT UTILITY: Other:1 5 3 Total Proposed Wa Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consiste building plans, specifications, and other calculations submitted with this permit application. The proposed interior systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.0.8.0 and to any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: MOUNTAIN FORGE REMODEL P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE LTG COMCHECK.cck Repor P STANTON HUMPHRIES, PE 7/30 Include the S2 and S6 fixtures from the common restrooms. Compliance Certificate d Designer/Contractor: Stanton Humphries AEC Avon, CO 970-748-8520 stan@aec-vail.com E REMODEL Provide a lighting comcheck for the commercial units. S Owner/Agent:Designer/Contractor: Stanton Humphries AEC Avon, CO 970-748-8520 stan@aec-vail.com Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) Common Space Types:Corridor/Transition <8 ft wide)2060 0.66 1360 1360Total Allowed Watts = Lighting Power E (C X D) D Fixture Watt. A D : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Common Space Types:Corridor/Transition <8 ft wide 2060 sq.ft.) WNLIGHT: Other:1 53 13 689 T AT BATHROOM: Other:1 2 13 26 T AT BATHROOM: Other:1 2 15 30 IP AT UTILITY: Other:1 5 32 160 905Total Proposed Watts = PASSES I count 51 R3 and R4 fixtures in the common areas. Revise comcheck. LOWER LEVEL (Entry canopy)300 ft2 0.25 Yes 75 MAIN LEVEL (Entry canopy)600 ft2 0.25 Yes 150 Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 225 225 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures LOWER LEVEL ( Entry canopy 300 ft2): Tradable Wattage LED 1: EX3: DOWNLIGHT: Other:1 2 23 46 LED 2: EX1: STEPLIGHT: Other:1 2 4 8 LED 3: EX5: SCONCE: Other:1 2 11 22 MAIN LEVEL ( Entry canopy 600 ft2): Tradable Wattage LED 4: EX1: STEPLIGHT: Other:1 6 4 23 LED 5: EX3: DOWNLIGHT: Other:1 9 23 207 LED 6: EX4: SCONCE: Other:1 3 15 45 LED 7: EX2: SCONCE: Other:1 5 11 55 LED 8: EX6: ACCENT: Other:1 2 9 17 423Total Tradable Proposed Watts = Project Title: Data filename: MOUNTAIN FORGE REMODEL P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE LTG COMCHECK.cck 07/30/18Report date: 72 ofPage I count 11 EX3 fixtures. Revise comcheck. Total Allowed Watts = Total Allowed Supplemental Watts (b) = 225 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures LOWER LEVEL ( Entry canopy 300 ft2): Tradable Wattage LED 1: EX3: DOWNLIGHT: Other:1 2 23 46 LED 2: EX1: STEPLIGHT: Other:1 2 4 8 LED 3: EX5: SCONCE: Other:1 2 11 22 MAIN LEVEL ( Entry canopy 600 ft2): Tradable Wattage LED 4: EX1: STEPLIGHT: Other:1 6 4 23 LED 5: EX3: DOWNLIGHT: Other:1 9 23 207 LED 6: EX4: SCONCE: Other:1 3 15 45 LED 7: EX2: SCONCE: Other:1 5 11 55 LED 8: EX6: ACCENT: Other:1 2 9 17 423Total Tradable Proposed Watts = Project Title: Data filename: MOUNTAIN FORGE REMODEL P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE LTG COMCHECK.cck 07/30/18Report date: 72 ofPage I count 4 EX4 fixtures. Revise comcheck. Page: [6] 18009 e1-E2.0 File Name: ELECTRICAL.PDF Subject: Electrical Code Author: mitchm Color: FYI note: Dimmer Switches. General-use dimmer switches shall be used only to control permanently installed incandescent luminaires unless listed for the control of other loads and installed accordingly. no dimmers allowed ELECTRICAL.PDF (13) Page: [7] 18009 e1-E2.1 File Name: ELECTRICAL.PDF Subject: PlanCheck Author: nickt Color: These panels penetrate the dwelling separation wall. Demonstrate how you will maintain the 1 hour fire and STC 50 rating. 2015 IBC 420, 1207. FD PROPER SETBAC EXISTING ADDITION UP TV ABOVE WH y FD FD FDCE BATHROOM 006 M S BEDROOM 003 BEDROOM 002 AHU 004 MECH. 1CHASE / EQUIP. RM. 008 CATERINGKITCHEN 007 COMM.UNIT 4 001 PANEL H HOUSE TELE PANEL COMM #4 MAIN TELE PANELCAT TELE AC GFI & TV TO TELE & TV PEDESTALS 30A2P DRYER WASHER F 2 E 5 ER 1 WH 1 B 1 EF 4 SF 4 RECEPTACLES SH. M TOTO M TO M TOMTO M TO M TO M TO M TO M TO WH 2 M TO AHU-1 AHU-3 AHU-5 AHU-7 AHU-9,11 AHU-13 AHU-15 CAT-1CAT-3 H-11 H-31 H-9 H-33 #4-1 #4-3 #4-7 #4-4 FUTURE NORTH BASEMENT POWER & SYSTEMS PLAN SCALE: 1/4" = 1'0" FYI note: Dimmer Switches. General-use dimmer switches shall be used only to control permanently installed incandescent luminaires unless listed for the control of other loads and installed accordingly. no dimmers allowed K-692ClairetteFaucetsBrass WH y DW REF AHU 102 COMM. 1 BATHROOM 101 103 COMM. UNIT 1 100 K-692ClairetteFaucetsBrass AHU 102 COMM. 1 BATHROOM 101 103 COMM. UNIT 1 100 K-692ClairetteFaucetsBrass EUH 4 TELE PANEL COMM #1 TELE PANEL AHU J HOOD 20A1P STOVE 50A2P AC GFI AC GFI REF AC GFI AC GFI AC GFI GARAGE DOOR DISC DW EXISTING TO REMAIN EUH 4 F 5 EF 7 M TO M TO AHU-4 AHU-6 AHU-8 AHU-10 AHU-12 AHU-14 AHU-16 AHU-18 AHU-20,22 H-16PARTIAL (E) (E) (E) These panels penetrate the dwelling separation wall. Demonstrate how you will maintain the 1 hour fire and STC 50 rating. 2015 IBC 420, 1207. Page: [7] 18009 e1-E2.1 File Name: ELECTRICAL.PDF Subject: PlanCheck Author: nickt Color: Section 420.7 Electrical vehicle charging. In Group R Occupancies, 3 percent of the total number of parking spaces, but not less than one, shall be electric vehicle charging stations (EVCS) capable of supporting future EVCS and shall be identified on the construction documents. Construction documents shall indicate the location of the proposed EVCS. At least one EVCS shall be located in common use areas and available for use by all residents. 420.7.1 Single EVCS required. When only one EVCS space is required, a 208/240-volt individual branch circuit or a listed raceway to accommodate a future individual branch circuit shall be installed. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of the electric vehicle charger. Construction documents shall identify the raceway termination point. The service panel or subpanel circuit directory shall provide capacity to install a 40-ampere minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent device. Electrical vehicle supply equipment shall be installed in accordance with NFPA 70. Page: [8] 18009 e1-E2.2 File Name: ELECTRICAL.PDF Subject: Electrical Code Author: mitchm Color: Hallways. In dwelling units, hallways of 3.0 m (10 ft) or more in length shall have at least one receptacle outlet. Page: [8] 18009 e1-E2.2 File Name: ELECTRICAL.PDF Subject: Electrical Code Author: mitchm Color: small-appliance branch circuits shall be permitted to supply receptacle outlets in the kitchen and other rooms specified in 210.52(B)(1). this does not comply TY L I N E PROPERTY LINE K L I N E SETBACK LINE AL L E Y EXISTING ADDITION EX I S T I N G AD D I T I O N K-692ClairetteFaucetsBrass 105sf 52sf DN DN SLOPE DNUP WH y DW REF GFE 7 5 3 6 4 ELEVATOR 1 AHU 102 RESTROOM 106 STAIR #1 104 COMM. 1BATHROOM 101 GARAGE 103 COMM.UNIT 1 100 K-692ClairetteFaucetsBrass ELEVATOR 1 AHU 102 RESTROOM 106 STAIR #1 104 COMM. 1BATHROOM 101 GARAGE 103 COMM.UNIT 1 100 K-692ClairetteFaucetsBrass EUH 2 HUH 2 EUH 4 EUH3 TELEPANELCOMM #1 TELE PANEL AHU J J J HOOD STOVE 50A2P ACGFI AC GFI REF GARAGE DOOR GARAGEDOOR TO UTILITYTRANSFORMER DISC DW METERBANK90"H X 32"W X 13.5"D MDP90"H X 42"W X 24"D ACGFI EUH 2 HUH 2 EUH 4 EUH3 F5 EF6 EF 7 EF8 HUH3 WPGFI +24"AFF GFI +24"AFFGFI M TO M TO M TO M TO M TO M TO M TO M TO AHU-4 AHU-6 AHU-8 AHU-10 AHU-12 AHU-14 AHU-20,22 TO LIGHTINGCIRCUIT H-16 H-18 H-20 H-22 PARTIAL H-16PARTIAL F1-29,31 50A2PUPSIZE CONDUIT TO 1-1/2"C F1-33 F1-35F1-37 (E) (E) (E) ww w . a e c - v a i l . c o m a PO B o x 8 4 8 9 , 4 0 8 0 1 U S H w y 6 & 2 4 , S t e 2 1 4 , A v o n , C o l o r a d o , 8 1 6 2 0 Me c h a n i c a l , E l e c t r i c a l & L i g h t i n g D e s i g n S e r v i c e s Ar c h i t e c t u r a l E n g i n e e r i n g C o n s u l t a n t s Te l e p h o n e : 9 7 0 - 7 4 8 - 8 5 2 0 ce MO U N T A I N F O R G E RE M O D E L & A D D I T I O N 20 0 - 2 3 4 E . H O P K I N S AS P E N , C O L O R A D O 8 1 6 1 1 An O f f i c e w i t h L E E D ™ A c c r e d i t e d P r o f e s s i o n a l s Section 420.7 Electrical vehicle charging. In Group R Occupancies, 3 percent of the total number of parking spaces, but not less thanone, shall be electric vehicle charging stations (EVCS) capable of supporting future EVCS and shall be identified on the construction documents. Construction documents shall indicate thelocation of the proposed EVCS. At least one EVCS shall be located in common use areas and available for use by all residents.420.7.1 Single EVCS required. When only one EVCS space is required, a 208/240-volt individual branch circuit or a listedraceway to accommodate a future individual branch circuit shall be installed. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate atthe main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of the electric vehicle charger. Construction documents shall identify the raceway termination point. The service panel or subpanel circuit directory shall provide capacity to install a 40-ampere minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent device. Electrical vehicle supply equipment shall be installed in accordance with NFPA 70. PROPERTY LINE PR O P E R T Y L I N E SE T B A C K L I N E MONARCH STREET EXISTING ADDITION DN UP FR. REF. U/C REF HANG MW PTRY. U/C WINE CLOSET FEC RES. 1CLOSET 204 RESIDENTIALLOUNGE 20X 20X RESIDENCESTUDY 20X UTILITY 215 ELEVATOR 1 MECH. 5 207 RESIDENTIALKITCHEN 200 CORRIDOR 2 216 RESIDENCEHALLWAY 203 RESIDENCE MASTER SUITE 206 RESIDENCEMASTER BATH 205 G S COMM UN 2 STAIR #1 212 RESIDENTIALGREAT ROOM 201 BrassFaucetsStillnessK-T948-4 ELEVATOR 1 BrassFaucetsStillnessK-T948-4 EUH 5 TELEPANELCOMM #6 TELE PANEL F & F1FREEMKT ACGFI HOOD20A1P COOKTOP 20A1P J +30" GFI +30" GFI AC GFI AC GFI ACGFI M STEAM SHOWER 50A2P GFI GFI ACAC ACGFI AC GFI AC GFI ACGFI J J FZR REF PROVIDE ELECTRIC HEAT MAT VIA GFI DEVICE. 12 W/SF, 120V 1P. PROVIDE 20A2P TSTAT. EUH 5 FC 2 EF 9 EF 10 H 1 H 2 UTTERS AND DOWNSPOUTS, PROVIDE (2) RUNS OF HEAT TRACE AT GUTTER, ONE AT OM OF GUTTER, ONE AT TOPBUILDING SIDE OF GUTTER.E DOWN DOWNSPOUTS AND ROVIDE 3' LOOP AT OUTLET. TYPICAL. J M TO M TO M TO FC1MTO M TO TO M TO M TO F-1 F-3F-5 F-7 F-9 F-11 F-13 F-15 F-17 F-19 F-21 F-23 F-25 F-27 F-29 F-31 F-33 F-14 F-16 F-18 F-20 F-22 F-24 F-26F-28,30 F1-1 F1-7 F1-3 TO LIGHTING CIRCUIT M TO F1-5 F-37,39 F1-9 F1-13 T H-28 H-30 H-39,41PARTIAL H-39,41PARTIAL NOR 2nd FLOOR POWER & SYSTEMS PLAN Hallways. In dwelling units, hallways of 3.0 m (10 ft) or more in length shall have at least one receptacle outlet. FR. REF. U/C REF MW PTRY. U/C WINE RESIDENTIAL LOUNGE 20X RESIDENTIAL DINING 20X RESIDENCE STUDY E RESIDENTIAL KITCHEN 200 COR 2 RESIDENTIAL GREAT ROOM 201 E AC GFI AC GFI HOOD 20A1P COOKTOP 20A1P J WALL OVEN 50A2P +30" GFI +30" GFI AC GFI STEA AC AC GFI AC GFI AC GFI AC GFI J FZR REF FC 2 H 1 H 2 EUH 7 M TO M TO M TO FC 1MTO M T F-1 F-3F-5 F-7 F-9 F-11 F-13 F-15 F-17 F-19 F-21 F-2 F-4 F-6 F-8 F-10 F-12 F-14 F-16 F-18 F-20 F-22 F-24 F-26F-28,30 F1-1 F1-7 F1-3 F-37, T H-39,41 PARTIAL small-appliance branch circuits shall be permitted to supply receptacle outlets in the kitchen and other rooms specified in 210.52(B)(1). this does not comply Page: [8] 18009 e1-E2.2 File Name: ELECTRICAL.PDF Subject: Electrical Code Author: mitchm Color: Hallways. In dwelling units, hallways of 3.0 m (10 ft) or more in length shall have at least one receptacle outlet. Page: [9] 18009 e1-E2.3 File Name: ELECTRICAL.PDF Subject: Electrical Code Author: mitchm Color: Circulation and Sanitation System, Location. Receptacles that provide power for water-pump motors or for other loads directly related to the circulation and sanitation system shall be located at least 1.83 m (6 ft) from the inside walls of the pool. Page: [9] 18009 e1-E2.3 File Name: ELECTRICAL.PDF Subject: Electrical Code Author: mitchm Color: Radiant Heating Cables Not Permitted. Radiant heating cables embedded in or below the deck shall not be permitted. Page: [9] 18009 e1-E2.3 File Name: ELECTRICAL.PDF Subject: Electrical Code Author: mitchm Color: Radiant Heating Cables Not Permitted. Radiant heating cables embedded in or below the deck shall not be permitted. Page: [9] 18009 e1-E2.3 File Name: ELECTRICAL.PDF Subject: Electrical Code Author: mitchm Color: Receptacles shall not be located less than 1.83 m (6 ft) from the inside walls of a storable pool, storable spa, or storable hot tub. PROPERTY LINE PROPERTY LINE SETBACK LINE EXISTING ADDITION DN UPREF. U/C REF DRAWERS BELOWHANGING PTRY. U/C WINE CLOSET FEC FDCE RES. 1CLOSET 204 RESIDENTIALLOUNGE 20X RESIDENCESTUDY 20X RESTROOM 211a 1 MECH. 5 207 RESIDENTIALKITCHEN 200 CORRIDOR 2 216 RESIDENCEHALLWAY 203 RESIDENCEMASTER SUITE 206 RESIDENCEMASTER BATH 205 GUESTSUITE 208 COMMERICALUNIT 6 211 STAIR #1 212 RESIDENTIALGREAT ROOM 201 BrassFaucetsStillnessK-T948-4 1 BrassFaucetsStillnessK-T948-4 EUH 5 TELE PANEL F & F1FREEMKT ACGFI AC GFI ACGFI M STEAMSHOWER 50A2P GFI WPGFI GFI AC GF ACGF ACACAC AC GFI ACGFI ACGFI ACGFI J REF PROVIDE ELECTRIC HEAT MAT VIA GFI DEVICE.12 W/SF, 120V 1P. PROVIDE 20A2P TSTAT. EUH 5 F 8 FC 2 EF 9 EF 10 EF 11 H 1 H 2 EF 12 J M TO M TO M TO FC 1MTO M TO M TO M TO M TO M TO F-1 F-3F-5 F-7 F-9 F-11 F-13 F-15 F-17 F-19 F-21 F-23 F-25 F-27 F-29 F-31 F-33 F-35 F-22 F1-1 F1-7 F1-3 TO LIGHTINGCIRCUIT TO LIGHTINGCIRCUIT M TO F1-5 F-37,39 F1-9 F1-13 T H-28 #6-4 #6-5 ,41TIAL H-39,41 PARTIAL NORTH 2nd FLOOR POWER & SYSTEMS PLAN SCALE: 1/4" = 1'0" Hallways. In dwelling units, hallways of 3.0 m (10 ft) or more in length shall have at least one receptacle outlet. EXISTING AD ELEVATOR DECORATIVE RIVER ROCK BALLAST 20 ' - 0 " S E T B A 10 ' - 0 " O V E R R EL E V A T O R & 15 ' - 0 " S E T B A 6'- 0 " M E C H A EQ U I P M E N T RD OD DN DN DN DN 10 - 0 " S E T B A PE R M A N E N T AM E N I T I E S - UP U/C REF U/C WINE U/C ICE UP WH y DS DN RD OD DN DN DN RD OD DN DN R DN WP GFI LED STRIP AT SHAFT WPGFI WPGFI J J J AC AC AC AC 50A2P WP RECEPTACLE FOR SPA. HR VIA GFI. 50A2P WP RECEPTACLE FOR SAUNA. HR VIA GFI. J J AT ROOF DRAINS, WRAP DRAIN TWICE AND LOOP HEAT TRACE 3' INTO BUILDING. AT ROOF DRAINS, WRAP DRAIN TWICE AND LOOP HEAT TRACE 3' INTO BUILDING. AT GUTTERS AND DOWNSPOUTS, PROVIDE (2) RUNS OF HEAT TRACE AT GUTTER, ONE AT BOTTOM OF GUTTER, ONE AT TOP BUILDING SIDE OF GUTTER. ROUTE DOWN DOWNSPOUTS AND PROVIDE 3' LOOP AT OUTLET. TYPICAL. F1-4 F1-6 F1-8 F1-18,20 HT HT F1-22,24 H-14PARTIAL H-39,41 PARTIAL H-39,41 PARTIAL H-39,41 PARTIAL H-39,41PARTIAL H-39,41PARTIA HT HT HT Circulation and Sanitation System, Location. Receptacles that provide power for water-pump motors or for other loads directly related to the circulation and sanitation system shall be located at least 1.83 m (6 ft) from the inside walls of the pool. RD OD DN DN DN DN UP UP WH y DN RD OD DN DN WP GFI 50A2P WP RECEPTACLE FOR SPA. HR VIA GFI. 50A2P FOR SA J AT ROOF DRAINS, WRAP DRAIN TWICE AND LOOP HEAT TRACE 3' INTO BUILDING. AT GUTTERS AND DOWNSPOUTS, PROVIDE (2) RUNS OF HEAT TRACE AT GUTTER, ONE AT BOTTOM OF GUTTER, ONE AT TOP BUILDING SIDE OF GUTTER. ROUTE DOWN DOWNSPOUTS AND PROVIDE 3' LOOP AT OUTLET. TYPICAL. F1-18,20 HT F1-22,2 H-39,41 PARTIAL H-39,41 PARTIAL H-39,41 PARTIAL H-39,41 PARTIALT Radiant Heating Cables Not Permitted. Radiant heating cables embedded in or below the deck shall not be permitted. DN RD OD DN DNDN DN RD OD DN DNDNWP GFI 50A2P WP RECEPTACLE FOR SPA. HR VIA GFI. J AT ROOF DRAINS, WRAP DRAIN TWICE AND LOOP HEAT TRACE 3' INTO BUILDING. F1-14,16 HT H-39,41 PARTIAL Radiant Heating Cables Not Permitted. Radiant heating cables embedded in or below the deck shall not be permitted. PROPERTY LINE DECORATIVE RIVER ROCK BALLAST RD OD DN RD O DN DN DN RD OD DN DNDNWP GFI 50A2P WP RECEPTACLE FOR SPA. HR VIA GFI. J AT ROOF DRAINS, WRAP DRAIN TWICE AND LOOP HEAT TRACE 3' INTO BUILDING. F1-14,16 HT AL H-39, PART Receptacles shall not be located less than 1.83 m (6 ft) from the inside walls of a storable pool, storable spa, or storable hot tub. Page: [9] 18009 e1-E2.3 File Name: ELECTRICAL.PDF Subject: Electrical Code Author: mitchm Color: Circulation and Sanitation System, Location. Receptacles that provide power for water-pump motors or for other loads directly related to the circulation and sanitation system shall be located at least 1.83 m (6 ft) from the inside walls of the pool. Page: [10] 18009 e1-E3.0 File Name: ELECTRICAL.PDF Subject: Time switch controls Author: nickt Color: Provide time switch controls to control lights in all locations without occupancy sensors as called for by 2015 IECC C405.2.2. Page: [10] 18009 e1-E3.0 File Name: ELECTRICAL.PDF Subject: Occupancy sensors Author: nickt Color: Provide occupancy sensor controls to control lights in all locations called for by 2015 IECC C405.2.1. Page: L-101 ROOF DECK•50MATERIALS•50PLAN File Name: LANDSCAPING.pdf Subject: PlanCheck Author: nickt Color: The architecturals do not show a sauna. Provide full detail and demonstrate compliance with 2015 IMC sauna provisions or eliminate from landscapes. LANDSCAPING.pdf (1) Page: [1] 18009-M1-M-001 File Name: MECHANICAL.PDF Subject: PlanCheck Author: nickt Color: Provide a mechanical comcheck for the mechanical equipment. MECHANICAL.PDF (5) PROPERTY LINE PR O P E R T Y L I N E SE T B A C K L I N E DECORATIVE RIVER ROCK BALLAST RD OD DN DN DN DN UP DN RD OD DN DNDNWP GFI J 50A2P WP RECEPTACLE FOR SPA. HR VIA GFI. AT ROOF DRAINS, WRA TWICE AND LOOP HEAT T INTO BU AT ROOF DRAINS, WRAP DRAIN TWICE AND LOOP HEAT TRACE 3' INTO BUILDING. F1-14,16 H-39,41 PARTIAL H-39,41 PARTIAL HT Circulation and Sanitation System, Location. Receptacles that provide power for water-pump motors or for other loads directly related to the circulation and sanitation system shall be located at least 1.83 m (6 ft) from the inside walls of the pool. T1 Provide time switch controls to control lights in all locations without occupancy sensors as called for by 2015 IECC C405.2.2. Provide occupancy sensor controls to control lights in all locations called for by 2015 IECC C405.2.1. The architecturals do not show a sauna. Provide full detail and demonstrate compliance with 2015 IMC sauna provisions or eliminate from landscapes. LL BE LOW VOLTAGE. THE MECHANICAL CHARACTERISTICS STEM PER THE REGARDLESS OF MPLETE AND OSS PROTECTION. NNECTS PROVIDED BY NTRACTOR. RIOR EQUIPMENT, NOR E CITY OF ASPEN NOISE O VERIFY COMPLIANCE. ARY HEATING. ERAL CONTRACTOR. Provide a mechanical comcheck for the mechanical equipment. Page: [2] 18009-M2-M-110 File Name: MECHANICAL.PDF Subject: PlanCheck Author: nickt Color: If this is to become a catering kitchen, provide shaft enclosure(s) for kitchen hood ducts. Page: [2] 18009-M2-M-110 File Name: MECHANICAL.PDF Subject: PlanCheck Author: nickt Color: Provide a fire damper where the outside air duct penetrates the dwelling separation. 2015 IBC 717. Page: [2] 18009-M2-M-110 File Name: MECHANICAL.PDF Subject: commercial ventilation Author: nickt Color: Indicate the CFM of outside air provided to each commercial unit. Provide calculations demonstrating compliance with 2015 IMC 403. Page: [4] 18009-M2-M-112 File Name: MECHANICAL.PDF Subject: PlanCheck Author: nickt Color: This electric unit heater penetrates the dwelling separation. Demonstrate how you will maintain the continuity of the 1 hour fire and STC 50 rating. 2015 IBC 420, 1207. Page: [4] 18009-P2-P-112 File Name: PLUMBING.PDF Subject: PlanCheck Author: nickt Color: These overflow drain outlets could be confused with the primary drain outlet location. The intent is for a building occupant to be able to notice if water is flowing from an overflow and know that there is a problem with the primary system. (2015 IPC 1108) PLUMBING.PDF (2) ALL BE ADJUSTABLE FROM NS WITH THE ARCHITECT. FDFDFD FD PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E SETBACK LINE SE T B A C K L I N E SE T B A C K L I N E MONARCH STREET EXISTING ADDITION EX I S T I N G AD D I T I O N BrassFaucetsStillnessK-T948-4 DN DN UP UP TV ABOVE UP FD FEC WH y FD FD FD B GFDCE MECH. 2 011 BATHROOM 006 MECH &STORAGE 005 BEDROOM 003 BEDROOM 002 RESTROOM 014 COMM.UNIT 5 016 AHU 004 COMM.UNIT 3 009STAIR #1 010 COMM. 3CORRIDOR 017 MECH. 1CHASE / EQUIP. RM. 008 RESTROOM 012 ELEVATOR 1 CATERINGKITCHEN 007 COURTYARD XXX COMM.UNIT 4 001 BrassFaucetsStillnessK-T948-4BrassFaucetsStillnessK-T948-4 HUH2EUH1 F 1 F2 F3 F 4 EF1 EF2 EF5 ERV 1 2" FLUE & 2" COMBUSTION AIR 2" FLUE & 2" COMBUSTION AIR 2" FLUE & 2" COMBUSTION AIR 2" FLUE & 2" COMBUSTION AIR 4" FLUE & 4" COMBUSTION AIR (2) 4" BOILER FLUE & 4" COMBUSTION AIR UP(2) 2" FURNACE FLUE & 2" COMBUSTION AIR UP (2) 2" FURNACE FLUE & 2" COMBUSTION AIR UP &(1) 4" BOILER FLUE & 4" COMBUSTION AIR UP B2 B3 WH1 B1 EF4 SF 4 A125-S18 x 3A115-S18 x 3 A 125-S18 x 3 8/8(10/10)12/8(14/10)16/10(18/12) 12/ 8 (1 4 / 1 0 ) 7"Ø (10"Ø) 7"Ø (10"Ø) 7"Ø (10"Ø) A 125-R18 x 3 A 125-R18 x 3 A 125-R18 x 3 5" OSA 7" OSA 7" OSA 7" OSA 9" OSA 14/10(17/13) 14x12 (17x15) OSA UP 4" DRYER EXHAUST UP 2 1 1 1 6" 6" 8" 10" Ø 12x10 UP 3 3 3 3 3 WH2 T F-1 TF-2 T F-3 12x12 (14x14)4 12x12 (14x14)4 12x12(14x14)44 12x12(14x14) 16x16 (18x18)5 16x16 (18x18)5 F/S F/S F/S 6 6 6 6 6 7 7 8 7 PERM NORTH BASEMENT HVAC PLAN SCALE: 1/4" = 1'0" If this is to become a catering kitchen, provide shaft enclosure(s) for kitchen hood ducts. PR O P E R T Y L I N E SE T B A C K L I N E AL L E Y EX I S T I N G AD D I T I O BrassFaucetsStillnessK-T948-4 UP 3 2 4 BATHROOM 006 MECH & STORAGE 005 AHU 004 BrassFaucetsStillnessK-T948-4BrassFaucetsStillnessK-T948-4 F 3 F 4 EF 5 ERV 1 2" FLUE & 2" COMBUSTION AIR 2" FLUE & 2" COMBUSTION AIR 4" FLUE & 4" COMBUSTION AIR B 1 A 125-S 18 x 3 12/8 (14/10) 16/10 (18/12) 12 / 8 (1 4 / 1 0 ) 7"Ø (10"Ø) 5" OSA 7" OSA 14x12 (17x15) OSA UP 2 1 3 3 3 12x12 (14x14)4 12x12 (14x14)4 F/S 6 6 6 7 8 Provide a fire damper where the outside air duct penetrates the dwelling separation. 2015 IBC 717. COMM. UNIT 4 001 Indicate the CFM of outside air provided to each commercial unit. Provide calculations demonstrating compliance with 2015 IMC 403. EXISTING ADDITION T/ROVDW FR. REF. MW UTILITY 215 ELEVATOR 1 JANITOR CLOSET 213 RESIDENTIAL KITCHEN STORAGE 214 ELEVATOR 1 CTS SIZED FOR SH. COILS, ZONE N AND SIZES EXH TO COMMON C-1. EXACT TH DOES NOT 10"Ø KITCHEN EXHAUST (BY OTHERS, SHOWN FOR REFERENCE, VERIFY SIZING W/KITCHEN CONSULTANT PRIOR TO INSTALLATION) AC 1 EUH 8 EUH 7 EF 13 BDD This electric unit heater penetrates the dwelling separation. Demonstrate how you will maintain the continuity of the 1 hour fire and STC 50 rating. 2015 IBC 420, 1207. 3"SD UP 3"OD UP 3"SD UP 3"OD UP DSN-1 DSN-1 DSN-1 DSN-1 4"SD 3"OD 4"SD 3"OD LEVEL ONE WAST These overflow drain outlets could be confused with the primary drain outlet location. The intent is for a building occupant to be able to notice if water is flowing from an overflow and know that there is a problem with the primary system. (2015 IPC 1108) Page: [5] 18009-P2-P-113 File Name: PLUMBING.PDF Subject: PlanCheck Author: nickt Color: Show where this overflow drains to. Must drain to a conspicuous above grade location. (2015 IPC 1108) Page: S4.0 DETAILS File Name: STRUCTURAL.PDF Subject: Micropiles Author: nickt Color: Provide micropile design drawings. If micropiles are to support a permanent load, they are permanent micropiles which must be designed with a minimum safety factor of 2 (2015 IBC 1810.3.3.1.7). STRUCTURAL.PDF (1) DN UP CLOSET FEC RES. 1 CLOSET 204 UTILITY 215 ELEVATOR 1 213 MECH. 5 207 CORRIDOR 2 216 C STAIR #1 212 ELEVATOR 1 9 FD-1 9 MS-1 8 212"V DN 112"V DN 112"V DN 112"W DN 2"V 3"RD UP 3"OD UP 3"SD UP 3" OD DN FD-1 2"V DN (INDEPENDENT) Show where this overflow drains to. Must drain to a conspicuous above grade location. (2015 IPC 1108) CONC WALL, RE: CONC WALL SCHEDULE CONC SOG, RE: PLAN CLR1 1/2" 3" #6 DOWEL TO MATCH OUTSIDE REINF VERT SPACING 3" FTG, RE: PLAN & SCHEDULE T/FTG MICROPILE WALL BY OTHERS T/SHEATHING RE: GEN NOTES WOOD FRAMING W/ SIMPSON HANGER, RE: PLAN & HANGER SCHEDULE RE: GEN NOTES CLASS B LAP SPLICE T/WALL EPOXY DOWEL #5 BAR TO CONC WALL, 6" MIN EMBED. MATCH REINF SPACING SCALE: SHEET TITLE: PROJECT NO: ©2018, KL&A, INC As indicated S4.0 B0551.000 DETAILS 3/4" = 1'-0" FOUNDATION DETAIL 07/31/2018 Provide micropile design drawings. If micropiles are to support a permanent load, they are permanent micropiles which must be designed with a minimum safety factor of 2 (2015 IBC 1810.3.3.1.7).