HomeMy WebLinkAboutFile Documents.230 E Hopkins Ave.0089.2018 (4).ACBK0089-2018-ACBK_BuildingComments_3_Markup Summary File Name: 230 E. Hopkins_ComCheck-Comm Units_2019-07-26.pdf Subject: PlanCheck Author: nickt Color: Page Label: 1 Page Index: 1 Which P light is this in the cutsheet package? If P1, the fixture must be labeled by the manufacturer with a maximum wattage matching the comcheck. Note this on Comcheck or provide a cutsheet with max fixture wattage. 230 E. Hopkins_ComCheck-Comm Units_2019-07-26.pdf (3) File Name: 230 E. Hopkins_ComCheck-Comm Units_2019-07-26.pdf Subject: PlanCheck Author: nickt Color: Page Label: 1 Page Index: 1 P3 fixture must be labeled by the manufacturer with a maximum wattage matching the comcheck. Note this on Comcheck or provide a cutsheet with max fixture wattage. File Name: 230 E. Hopkins_ComCheck-Comm Units_2019-07-26.pdf Subject: PlanCheck Author: nickt Color: Page Label: 3 Page Index: 3 Fill out owner/agent File Name: 230 E. Hopkins_ComCheck-CommonAreas_2019-08-26.pdf Subject: PlanCheck Author: nickt Color: Page Label: 1 Page Index: 1 S6 cut sheet lists wattage as 2 x 40 = 80. 230 E. Hopkins_ComCheck-CommonAreas_2019-08-26.pdf (2) File Name: 230 E. Hopkins_ComCheck-CommonAreas_2019-08-26.pdf Subject: PlanCheck Author: nickt Color: Page Label: 2 Page Index: 2 Fill out owner/agent 4107Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures #2 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 322 sq.ft.) LED 9: R3: DOWNLIGHT: Other:1 3 12 36 LED 10: TR1 & TR2: TRACK LIGHT: Other:1 12 15 180 #3 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 655 sq.ft.) LED 11: R3: DOWNLIGHT: Other:1 13 12 156 LED 12: P: PENDANTS: Other:1 3 20 60 #4 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 1585 sq.ft.) LED 1: R3 & R4: DOWNLIGHT: Other:1 22 12 264 LED 2: P2: PENDENT AT BATHROOM: Other:1 4 60 240 LED 3: P3: PENDENT AT BATHROOM: Other:1 1 15 15 LED 4: T1: LED STRIP AT UTILITY: Other:1 1 32 32 LED 5: S2: SCONCE: Other:1 2 9 18 LED 5 copy 1: S3: SCONCE: Other:1 3 60 180 LED 6: TR1 &TR2: TRACK: Other:1 4 15 60 LED 7: C1: PENDANT AT POOL TABLE: Other:1 1 45 45 #5 COMMERCIAL ( Common Space Types:Office - Enclosed 133 sq.ft.) LED 18: T1: LED STRIP: Other:1 2 32 64 Project Title: Data filename: MOUNTAIN FORGE TENANT FINISH P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE TI LTG COMCHECK.cck 07/11/19Report date: 71 ofPage Which P light is this in the cutsheet package? If P1, the fixture must be labeled by the manufacturer with a maximum wattage matching the comcheck. Note this on Comcheck or provide a cutsheet with max fixture wattage. #2 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 322 sq.ft.) LED 9: R3: DOWNLIGHT: Other: LED 10: TR1 & TR2: TRACK LIGHT: Other: #3 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 655 sq.ft.) LED 11: R3: DOWNLIGHT: Other: LED 12: P: PENDANTS: Other: #4 COMMERCIAL UNIT ( Common Space Types:Office - Enclosed 1585 sq.ft.) LED 1: R3 & R4: DOWNLIGHT: Other: LED 2: P2: PENDENT AT BATHROOM: Other: LED 3: P3: PENDENT AT BATHROOM: Other: LED 4: T1: LED STRIP AT UTILITY: Other: LED 5: S2: SCONCE: Other: LED 5 copy 1: S3: SCONCE: Other: LED 6: TR1 &TR2: TRACK: Other: LED 7: C1: PENDANT AT POOL TABLE: Other: #5 COMMERCIAL ( Common Space Types:Office - Enclosed 133 sq.ft.) LED 18: T1: LED STRIP: Other: Project Title: Data filename: MOUNTAIN FORGE TENANT FINISH P:\Current Projects\18009.00 - Mountain Forge Building Renovation & Addition\Calculations\COMcheck\MOUNTAIN FORGE TI LTG COMCHECK.cck P3 fixture must be labeled by the manufacturer with a maximum wattage matching the comcheck. Note this on Comcheck or provide a cutsheet with max fixture wattage. COMcheck Software Version 4.1.1.0 Exterior Lighting Compliance Certificate 90.1 (2013) Standard Alteration Site: HOPKINS 81611 Owner/Agent:Designer/Contractor: Stanton Humphries AEC Avon, CO 970-748-8520 stan@aec-vail.com ormation MOUNTAIN FORGE TENANT FINISH 2 (Residential mixed use area)ng Zone xterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 0 0 600 e tradeoffs are only allowed between tradable areas/surfaces. Fill out owner/agent Watt.Fixture Fixtures e Types:Corridor/Transition <8 ft wide 2060 sq.ft.) 1 56 12 666 M: Other:1 2 60 120 M: Other:1 2 15 30 ther:1 6 28 168 her:1 9 6 57 her:1 2 20 40 1081Total Proposed Watts = tatement ed interior lighting alteration project represented in this document is consistent with the her calculations submitted with this permit application. The proposed interior lighting et the 90.1 (2013) Standard requirements in COMcheck Version 4.1.1.0 and to comply with ents listed in the Inspection Checklist. Signature Date EMODEL 18009.00 - Mountain Forge Building Renovation & 07/11/19Report date: 71 ofPage S6 cut sheet lists wattage as 2 x 40 = 80. COMcheck Software Version 4.1.1.0 Exterior Lighting Compliance Certificate 90.1 (2013) Standard Alteration e: OPKINS 1611 Owner/Agent:Designer/Contractor: Stanton Humphries AEC Avon, CO 970-748-8520 stan@aec-vail.com rmation MOUNTAIN FORGE REMODEL 2 (Residential mixed use area) Zone erior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / Unit D Tradable Wattage E Allowed Watts (B X C) L (Entry canopy)300 ft2 0.25 Yes 75 Entry canopy)600 ft2 0.25 Yes 150 (Walkway >= 10 feet wide)1809 ft2 0.14 Yes 253 Total Tradable Watts (a) =478 Fill out owner/agent P3 is ordered as a set of component parts. LED lamping at 120v from the factory is 4w. P3's note in the luminaire schedule is updated to require mfr label indicating "max 15w lamp" in order to comply wiht ComCheck calculation. We have provided for 3 j-boxes for a future tenant supplied pendant (tenant has not chosen this yet which is why these are labeled "P"). So wattages in commcheck are the max tenant will be allowed to install. Yes, this is correct. ComCheck has been updated All owner/agent fields have been updated. See updated ComChecks. All owner/agent fields have been updated. See updated ComChecks. 09/06/2019 File Name: 230 E. Hopkins_Drawings_Architectural--NICK_2019-08-07.pdf Subject: PlanCheck Author: nickt Color: Page Label: A2.0 PROPOSED BASEMENT FLOOR PLAN Page Index: 23 Provide more information on Commercial Unit 5. It now appears to be a commercial kitchen. What is the intended use and is it related/accessory to any other units? As a commercial kitchen, it is an employee work area only requiring an accessible entrance, turnaround, and exit. However, if it is a break room for another office, then it must be fully accessible (provide enlarged plan and elevations demonstrating compliance). If it is a commercial kitchen, exhaust is required and a type II and/or type I hood may be required depending on the equipment installed. If the dishwasher is a residential level model, and a hood is not required by the install instructions, then no hood will be required. It appears that it may be serving as a back of house kitchen to Unit 4. If unit 4 is to become a restaurant, provide seating layout and occupant calculations and update plumbing fixture calculations. In future, please provide a document outlining any changes you have made since the last round that are not in response to comments. 230 E. Hopkins_Drawings_Architectural--NICK_2019-08-07.pdf (6) File Name: 230 E. Hopkins_Drawings_Architectural--NICK_2019-08-07.pdf Subject: PlanCheck Author: nickt Color: Page Label: A2.0 PROPOSED BASEMENT FLOOR PLAN Page Index: 23 Provide enlarged plan and elevations with dimensions demonstrating accessibility at the Unit 4 bar. This includes: -Centerline of sink must be 24" from edge of dishwasher to allow for clearspace to be out of dishwasher door swing. -A portion of the bar seating must be accessible. Minimum 5' wide (to accommodate a companion) portion of the counter at 34" max height for full depth of counter with knee and toe clearance. File Name: 230 E. Hopkins_Drawings_Architectural--NICK_2019-08-07.pdf Subject: PlanCheck Author: nickt Color: Page Label: A5.1 PROPOSED BUILDING SECTIONS Page Index: 33 Provide an enlarged detail of this condition where the dwelling separation continuity is wrapped up to the underside of the floor sheathing without interruption by the joists or other structure. Provide details at any other similar conditions. ˆ )')' 83 83 %UDVV)DXFHWV6WLOOQHVV.7˝˙ '1 83 79$%29( 79 0(',$',63/$< 83 )' )(& :+\ )' )' )' )' )' *2/)6,08/$725 8&5()8&5()': )' ':8&,&( %8,/',1*$%29( (;, 6 7 % 8 , / ' , 1 * $ % 2 9 ( %8 , / ' , 1 * $ % 2 9 ( %8,/',1*$%29( %8 , / ' , 1 * $ % 2 9 ( :+ $($&')*% ˇ ˆ ˇˆ ˘ ˇ˙ 3523(57</,1( 352 3 ( 5 7 < / , 1 ( 3523(57</,1( 352 3 ( 5 7 < / , 1 ( ˘˙˙ 6(7%$&./,1( 6(7 % $ & . / , 1 ( 6(7%$&./,1( 6(7 % $ & . / , 1 ( 021$5&+675((7 +2 3 . , 1 6 $ 9 ( 1 8 ( $// ( < $˘ ˙˙ ˘˙˙˙ (;,67,1*$'',7,21 $˘ (;, 6 7 , 1 * $' ' , 7 , 2 1 (;, 6 7 , 1 * $' ' , 7 , 2 1 $˘ 6&$/(˛ 352326(' %$6(0(17)/2253/$1 ˇ $3/ 12 &20081,7 &2857<$5' &20081,7˘ˆ (/(9$725 5(675220 0(&+&+$6((48,350˙ &255,'25ˆ 67$,5 &20081,7ˇ ˝ $+8 1(: :,1'2::(//,1&5($6('(37+)25&2'(&203/,$17(*5(66 )520%('522066,//$70$;)520),1,6+)/225 ˙ &20081,7 ˇ &/ 2 6 ( 7 5(675220 0(&+ ˘ ˘ ˙˝ %('5220 %('5220 0(&+6725$*( ˘ $+8%$7+ ˇ ˆ ˆ˙ ˘ ˇ ˝ ˘ $ $%9 $%9 $%9 ˇ $%9(;,67&2/801 $%9 ˘ $%9 ˇ $%9 ˆ 726/$%˙˙˘˙ 0(&+ :˘$ˆ :ˆ$ˆ:$ˆ $ˇ˘ :$ˆ :)$ˆ:ˆ)$ˆ :˘6,0 $ˆ :˘6,0$ˆ : $ˆ :ˇ $ˆ :ˇ$ˆ:ˇ$ˆ +$// $ˇ 726/$%(˙˙˘˙ :$ˆ:$ˆ: $ˆ : $ˆ:$ˆ :$ˆ ') $ˇ $ˇ :˘$ˆ :˘$ˆ ),5(63.5 (175< ˇ˙ ˘ˇ ˘ˇ ˘˘˙˙˝ˇ˘˙ ˇ ˙ :$7(56(59,&((175<9$/9( :˙ $ˆ :ˇ$ˆ 5(/2&$7('(/(&3$1(/ 0,&523,/(:$// 0,&523,/(:$// 3/$ 1 7 , 1 * * $ 3 $ˇˆ *8$5'5$,/ $ˇˆ 72&2857<$5'˝˝˙ % ˝˝ &/26(7 ˝D 0(&+ ˝E ˙&/5 &2817(5$7 $)) $ˇˇ :$ˆ :ˇ$ˆ 0,& 5 2 3 , / ( : $ / / :' :25.7$%/( :25 . 7 $ % / ( :25 . 7$% / ( $ˆ ˆ )855,1*72$/,*1 :,7+$'-$&(17:$// :$ˆ &+$6($%29(:ˇ$ˆ 3$57<:$//;ˇ$,5*$3; $ˆˆ$ˆˆ ),(/'9(5,)<(;7(1762)(;,67&21&)'1:$//#/9/%($0 %($5,1*327(17,$/1(:&2/801 :$ˆ 6,0 6,0 $ˆˆ 6,0 (;,67&21&:$//72 5(0$,1 Provide more information on Commercial Unit 5. It now appears to be a commercial kitchen. What is the intended use and is it related/accessory to any other units? As a commercial kitchen, it is an employee work area only requiring an accessible entrance, turnaround, and exit. However, if it is a break room for another office, then it must be fully accessible (provide enlarged plan and elevations demonstrating compliance). If it is a commercial kitchen, exhaust is required and a type II and/or type I hood may be required depending on the equipment installed. If the dishwasher is a residential level model, and a hood is not required by the install instructions, then no hood will be required. It appears that it may be serving as a back of house kitchen to Unit 4. If unit 4 is to become a restaurant,provide seating layout and occupant calculationsand update plumbing fixture calculations.In future, please provide a document outliningany changes you have made since the last roundthat are not in response to comments. ˆ )')' '1 79$%29( 79 83 )' )(& :+\)' )' 8& 5() 8& 5() ': ':8& ,&( %8 , / ' , 1 * $ % 2 9 ( %8,/',1*$%29( 3523(57</,1( 35 2 3 ( 5 7 < / , 1 ( 6( 7 % $ & . / , 1 ( &20081,7 &2857<$5' &200 81,7˘ ˆ (/(9$725 &255,'25 ˆ 1(: :,1'2::(// ,1&5($6('(37+)2 &2'(&203/,$17(*5 )520%('52206 6,//$70$;)52 ),1,6+)/225 ˙ &20081,7 ˇ ˘ ˙˝ %('5220 % ˆ ˆ˙ ˘ $ $%9 $%9 $%9 ˇ $%9(;,67 &2/801 $%9 ˘ $%9 ˇ $%9 ˆ $ˇ˘:ˇ $ˆ :ˇ $ˆ $ˇ 726/$%( ˙˙˘˙ : $ˆ : $ˆ : $ˆ $ˇ :˘ $ˆ :˘ $ˆ :$7(56(59,&( (175<9$/9( 3/ $ 1 7 , 1 * * $ 3 $ˇˆ *8$5' 5$,/ $ˇˆ 72&2857<$5' ˝˝˙ % ˙&/ 5 &2817(5$7 $)): $ˆ :25.7$%/( :2 5 . 7 $ % / ( :2 5 . 7$ % / ( $ˆ : $ˆ 3$57<:$// ;ˇ $,5*$3 ; $ˆˆ$ˆˆ ),(/'9(5,)<(;7(176 2)(;,67&21&)'1 :$//#/9/%($0 %($5,1*327(17,$/ 1(:&2/801 : $ˆ 6,0 6,0 Provide enlarged plan and elevations with dimensions demonstrating accessibility at the Unit 4 bar. This includes: -Centerline of sink must be 24" from edge of dishwasher to allow for clearspace to be out of dishwasher door swing. -A portion of the bar seating must be accessible. Minimum 5' wide (to accommodate a companion) portion of the counter at 34" max height for full depth of counter with knee and toe clearance. 6&$/(˛ 352326('%8,/',1*6(&7,21 ˇ $˘ $//(< ˘˘ ˙ 723/</(9(/7:2( ˙ 72&21&%$6(0(17 ˙˙˘˙ 723/<522)(˙ ˆ˙ ˆ˙ 72522)'(&.$ ˙ 723$5$3(7 ˇˆ ˇ 35 2 3 ( 5 7 < / , 1 ( 6( 7 % $ & . 5 $ˆ 5 $ˆ ˙ *8(6768,7( ˝ *8(6768,7( ˇ )ˇ $ˆ )ˇ $ˆ ) $ˆ 6,0 $+8%$7+ ˇ 6/23('1 7233,1*6/$%21 &20326,7('(&. ˙˙ )ˆ $ˆ /,1(2)352326(' *5$'(5(˛&,9,/ 75$6+5(&<&/( %,16 $+8 ˝ ˘ $ˆ ) $ˆ ) $ˆ 8220 $+8%('5220 $+8 &20081,7 : $ˆ 723/</(9(/21(%<1' 723/</(9(/21($'8 ˝˝ˇ ˆ $ˆ6,02+ 0,&523,/(:$// 5(˛6+25,1* '(6,*1 ˙ 5 $ˆ Provide an enlarged detail of this condition where the dwelling separation continuity is wrapped up to the underside of the floor sheathing without interruption by the joists or other structure. Provide details at any other similar conditions. Sheet A9.5B has been added. Commercial Unit 5 is a staging facility only. No food preparation will be done in this room. An exhaust fan has been added. It will be rented as its own unit. See sheets A5.1 - A5.3 building sections - occupancy separation continuity details keyed at wall/floor transitions. See A7 series for enlarged detail info. See new details on sheet A7.07A. 09/06/2019 File Name: 230 E. Hopkins_Drawings_Architectural--NICK_2019-08-07.pdf Subject: PlanCheck Author: nickt Color: Page Label: A6.26 MECH. SHAFT DRAWINGS Page Index: 45 W9/A7.01 references UL U415 which is a vertical assembly. Systems tested vertically (walls) may not be used horizontally per UL general notes. File Name: 230 E. Hopkins_Drawings_Architectural--NICK_2019-08-07.pdf Subject: PlanCheck Author: nickt Color: Page Label: A6.26 MECH. SHAFT DRAWINGS Page Index: 45 The shaft details are complicated and do not appear to be constructible. Installing two layers of drywall with tape and mud on the inside of the shaft seems infeasible after rough ins have been installed. Why the double wall? Also, you are now enclosing the bottom of the shaft which relieves the need to rate the mechanical room. File Name: 230 E. Hopkins_Drawings_Architectural--NICK_2019-08-07.pdf Subject: PlanCheck Author: nickt Color: Page Label: A7.09 DETAILS Page Index: 59 Include detail 09 21 16.23.163 Shaft Wall Intermediate Floor Base Overhang in the plans and reference it here. File Name: 230 E. Hopkins_Drawings_Mechanical_2019-07-26.pdf Subject: PlanCheck Author: nickt Color: Page Label: M-110 BASEMENT HVAC PLAN Page Index: 2 Commerical unit 5 now appears to be a commercial kitchen. Provide appropriate ventilation and exhaust per requirements of 2015 IMC chapters 4 and 5. 230 E. Hopkins_Drawings_Mechanical_2019-07-26.pdf (1) File Name: 230 E. Hopkins_Drawings_Structural_2019-07-26.pdf Subject: PlanCheck Author: nickt Color: Page Label: S2.2 LEVEL TWO FLOOR FRAMING PLAN Page Index: 14 Fire rate all columns that support the roof joists that extending out from Grid 7 (this is for 2015 IBC 705.11 exception 4.2 parapet exception). Columns must be individually encapsulated per 2015 IBC 704.2. 230 E. Hopkins_Drawings_Structural_2019-07-26.pdf (1) 1-HOU HORIZ FLOO ASSE F6 A7.02 SIM. F2 A7.02 COMM.UNIT 1 100 SHAFT ENCLOSURE SHAFT ENCLOSURE PENETRATIONS SHALL BE PROTECTED BY DAMPERS AS REQUIRED BY CODE - RE: MECHANICAL DOCUMENTATIONW10 A7.01 1-HOUR HORIZONTAL FLOOR/CEILING ASSEMBLY EXIST. FDN WALL TO REMAIN; 1-HOUR RATED NOTE: DUCTS RUNNING UP INTO SHAFT ENCLOSURE SHALL BE PROTECTED BY FIRE DAMPERS AT THIS LEVEL PER IBC 713.11.3. GARAGE 103 1-HOUR BARRIER (SHAFT WALL) INSTALL FROM SHAFT SIDE W9 A7.01 1-HOUR BARRIER (SHAFT WALL); INSTALL FROM SHAFT SIDE @ THIS LOCATION EXISTING WALL TO REMAIN; 1 HOUR FIRE RATED; COMPLETE INSTALL PRIOR TO INSTALL OF ADJACENT SHAFT WALL 1 H O U R S H A F T W A L L 1-HO BARR (SHA W9 A7.01 1-HOUR HORIZONTAL FLOOR/CEILING ASSEMBLY FACE OF STUD FRAMING TO ALIGN W/ FACE OF EXISTING GLU-LAM BEAM THIS SIDE TERMINATE SHAFT WALL @ CONC. FDN WALL PER UL REQ'S 1 A7.09 SIM. 3 1/4" +/- FLOOR OVERHANG (FIELD VERIFY) 1-HOUR HORIZONTAL ENCLOSURE @ BOTTOM OF SHAFT, INSTALL PER UL REQ'S W9 A7.01 FURRED WALL FURR 1-HOUR RATED WALL W9/A7.01 references UL U415 which is a vertical assembly. Systems tested vertically (walls) may not be used horizontally per UL general notes. T.O. PLY LEVEL TWO (E) 111'-1 3/8" 0 2 ISTING WALL TO MAIN; HOUR FIRE RATED; OMPLETE INSTALL IOR TO INSTALL OF HOUR BARRIER HAFT WALL) STALL FROM HAFT SIDE @ IS LOCATION HOUR HORIZONTAL OOR/CEILING SEMBLY HOUR BARRIER HAFT WALL) ONTINUOUS Revision: The shaft details are complicated and do not appear to be constructible. Installing two layers of drywall with tape and mud on the inside of the shaft seems infeasible after rough ins have been installed. Why the double wall? Also, you are now enclosing the bottom of the shaft which relieves the need to rate the mechanical room. Include detail 09 21 16.23.163 Shaft Wall Intermediate Floor Base Overhang in the plans and reference it here. FEC FD DW U/C ICE COMM. UNIT 5 007 1 MECH. 1 CHASE / EQUIP. 008 CORRIDOR 017 BEDROOM 002 BEDROOM 013 EH 1 F 2 2" FLUE & 2" COMBUSTION AIR B 2 WH 1 EF 4 SF 4 A 125-R 18 x 3 A 125-R 18 x 3 A 535-R 54 x 3 9" OSA 4" DRYER EXH 1 1 8" 8" Ø 12x10 UP 3 WH 2 TF-2 26x10 (28x12) 26 x 1 0 (2 8 x 1 2 ) F/S F/S 6 6 12BD D 8/8 (10/10) 8"Ø (11"Ø) (TYP. OF 3) 7"Ø (10"Ø) 7"Ø (10"Ø) BDD6" OSA 10 T EH-1 12" OSA 8" OSA 8 2 14 14 2" FLUE & 2" COMBUSTION AIR MD 9 M A 1810-R 24x24 Commerical unit 5 now appears to be a commercial kitchen. Provide appropriate ventilation and exhaust per requirements of 2015 IMC chapters 4 and 5. A 7 B C D E F 2 3 4 5 6 100'-0" 10'-5 1/4"18'-8"5'-8 1/8"26'-4 3/4"14'-8 1/2" 60'-0" 5'-5 3/8" 15'-0 3/4" 6'-7 1/4" 8'-1 3/8" 17'-11 1/4" 6'-10" (E) W10x22(E) W10x22(E) W10x22(E) W10x22 (E)W12x26 (E ) W 1 6 x 3 1 (E) 5.125x12 GLB(E) 5.125x12 GLB(E) 5.125x12 GLB(E) 8.75x18 GLB T/SHE 111'- T W14 14 " T J I 3 6 0 @ 1 6 " O C (3) 7 HS S4 x4x1 / 9 1/2 TJI 210@16"OC (E) 2x6@16"OC (E) 10" TJI@16"OC 9 1 / 2 T J I 2 1 0 @ 1 6 " O C (E) 10" TJI/35@16"OC (E) 12" TJI/35@16"OC H SS 4x4 x5 /1 6 H S S4 x4 x1 /4 HS S 4x 4x 1/4 MO M E N T F R A M E HSS 4x 4x1/4 H SS 4x4 x1/4 1 H SS 4x4 x5 /1 6 W1 8 x 3 5 1S4.2 11 7/8 TJI 210@16"OC (2) 9 1/2" LVL(2) 9 1 / 2 " L V L T/SHEATHING 111'-1 3/8" EXISTING T/SHEATHING 111'-1 3/8"A3 5S4.1 7S4.1 (2) 14" LVL (E) W18x65 H S S4 x4x1 /4 H SS 4 x4 x1/4 6S4.2 6" 44 K W1 4 x 6 1 49 K (E) W18x65 12K 47 K W14 x 6 1 27 K 2 6'-0 3/4" 9 1/2 TJI 210@16"OC 9 1/2" LVL@16"OC AT FIREPLACE A2 R H SS4 x4 x1 /4 2 A 18 13S4.2 2 2 22 HS S 4x 4x 1/4 HSS4x4x1/4 15S4.2 16S4.3 1S4.3 7 1/4" LVL@ 6S4.3 3 W1 110'-1 5K 6K W8x15 110'-5 7/8" 6K 6K W8x15 110'-5 7/8" 6K HS S4x4x1/4 (2) 11 7/8" LVL 11 7 / 8 " T J I 2 1 0 @ 1 6 " O C 16S4.3 (2) 11 7/8" LVL (E) 5.125x15 GLB H4 H4 H3 H3 H2 H3 H4 H10 H10 H10 H12 H12 H12 6 3/4" 17S4.3 17S4.3 1 1 HS S4x4x1/4 HS S 4 x 4 x 1 / 4 HSS4x4x1/4 (2) 7 1/4" LVL 1S4.4 H14 H14 2 4S4.4 (E ) W 1 8 x 6 5 T/CONC 111'-4" 4 SIM T/CMU 110'-11 1/8" B/CONC111'-0 5/8" (E ) W 1 2 x 2 6 (E ) W 1 2 x 2 6 11 7 / 8 " T J I 2 1 0 @ 1 6 " O C 11 7 / 8 " T J I 2 1 0 @ 1 6 " O C (2 ) 9 1 / 2 " L V L 5 Fire rate all columns that support the roof joists that extending out from Grid 7 (this is for 2015 IBC 705.11 exception 4.2 parapet exception). Columns must be individually encapsulated per 2015 IBC 704.2. Bottom of shaft has been designed to terminate at a mechanical room separated with 1 hour fire barriers. Enclosure at the bottom of the shaft has been removed as clarified in our telephone conversation. See sheet A6.26 Design of the shaft has been simplified for constructability. See sheets: A6.26 / A7.09 / A2.0 - A2.2 floor plan sheets. New shaft wall UL U415 System F (alternate) selected for the project. See sheet A7.0C & W9/A7.01 Shaft dwg info has been updated. See sheet A6.26 & A7.09 Floor/shaft wall junction details added - see sheet A7.0C Commercial Unit 5 is a staging facility only. An exhaust fan has been added. See building sections 1/A5.1 + 1/A5.2 for detail callouts and 1 hour encapsulation @ beams @ Level 2 and supporting structure See sheet A7.08 for enlarged details and 1 hour beam encapsulation See sheet A/2.1 Level 1 floor plan & A/2.0 Basement floor plan for supporting column 1 hour protection detail callouts See sheet A7.30D for Design No. X528 UL Design 263 UL 1 hour column protection 09/06/2019 File Name: 230 E. Hopkins_Lighting_Spec Package_2019-07-26.pdf Subject: PlanCheck Author: nickt Color: Page Label: D1 Page Index: 2 Provide cut sheet showing listing by a nationally recognized testing lab. 230 E. Hopkins_Lighting_Spec Package_2019-07-26.pdf (2) File Name: 230 E. Hopkins_Lighting_Spec Package_2019-07-26.pdf Subject: PlanCheck Author: nickt Color: Page Label: P2.1 Page Index: 4 Provide cut sheet showing listing by a nationally recognized testing lab. T1711BN tskirt Flush Mount ushed Nickel DETAILS Material: Aluminum Glass/Shade Descri Remote Included: N LAMPING Light Source: Integr Provide cut sheet showing listing by a nationally recognized testing lab. VIE Home / Catalogue / Pendant Light / Brompton, Size 2 Anthracite Glass Pendant U PRODUCTS ABOUT US NEWS CONTACT Provide cut sheet showing listing by a nationally recognized testing lab. Additional page added to lighting package indicating the fixture is ETL-Intertek listed Page P2.3 shows the UL listed label, pages 2.4 & 2.5 shows mfr. install instructions with UL label and max wattages. 09/06/2019