Loading...
HomeMy WebLinkAboutFile Documents.747 S Galena St.0122.2019 (29).ARBK0122-2019-arbk_building comments_1 Subject: PlanCheck Page Label: 1 Page Index: 1 Author: tonyf Date: 6/10/2019 9:55:35 AM File Name: Plan Set.pdf Plan Set.pdf (4) Subject: PlanCheck Page Label: 3 Page Index: 3 Author: tonyf Date: 6/10/2019 10:52:12 AM File Name: Plan Set.pdf Provide documentation that 1-hr dwelling separation and STD rating will be maintained Subject: PlanCheck Page Label: 3 Page Index: 3 Author: tonyf Date: 6/10/2019 11:14:55 AM File Name: Plan Set.pdf Provide engineer letter verifying that no structural walls are being removed Subject: PlanCheck Page Label: 3 Page Index: 3 Author: tonyf Date: 6/10/2019 10:52:58 AM File Name: Plan Set.pdf Provide documentation that 1-hr dwelling separation and STD rating will be maintained BY REVISIONS DATEJob:SheetDate:Scale:Drawn: A1.01 5/7/2019Plotted On: 5/7/2019AS NOTED TI T L E S H E E T / GENERAL INFO D:\ ar c h i c a d p r o j e c t f o l d e r \Pe r s o n a l P r o j e c t s \170 Fasching\_New Project Template\Project PLN\PLN - BPN - BACKUPS\170 fasching.pln IF THE ABOVE DIMENSION DOESNOT MEASURE ONE INCH (1")EXACTLY, THIS DRAWING WILL HAVEBEEN ENLARGED OR REDUCED,AFFECTING ALL LABELED SCALES.1" ACTUAL 9:15 AM J.MFasching HAUS #170 747 S GALENA ST , ASPEN CO.FASCHING HAUS #170747 s galena stASPEN, COLORADOPROJECT DESCRIPTION:Parcel Id:LOT SIZE:SQ. FOOTAGE/ALLOWABLEFLOOR AREA:LAND USE ZONE:DESIGN CRITERIA:ground snow Load: 100 psfwind speed/exposure Category: 89/BSeismic Design: cWeathering: Severefrost line; 36"termite: none to slightdecay: none to slightwinter design temp: - 15 deg fsummer design Temp: 82 deg fice shield underlayment required: yesflood hazard:air freezing index: 2000mean annual temp: 40 degreesGENERAL CONTRACTOR:STRUCTURAL ENGINEER:R-3 DWELLING UNITTYPE v ERNEST KOLLAR ENGINEERS, INC.320 MAIN STREET, SUITE #203CARBONDALE, CO. 81623(970)963-3223 VOICE(970)963-9395 FAXerniekollar@sopris.netinterior remodel unit 170 faschingOCCUPANCY TYPE:CONSTRUCTION TYPE:r - 15273718278019doug Hayes ConstructionPhone: 970-618-6525dhayesconsturction@gmail.comBUILDING CODE ANALYSIS:ordinances: code questions: BUILDEROFTHEDAY@GMAIL.COM BUILDER OF THE DAY AT 970-429-2735 ENERGY CODE COMPLIANCE:2015 International Building Code Adopted appendicies C, E, I, J 2015 International Residential Code Chapters 1-10 Only!Adopted Appendices E, F, H, J, K, R, S, U 2015 International Energy Conservation Code 2015 International Plumbing Code 2015 International Mechanical Code 2015 International Fuel Gas Code 2015 International Fire Code 2015 International Existing Building Code 2015 International Swimming Pool and Spa Code 2015 International Solar EnergyProvisions ICC A117.1-2009 Accessible and Usable Buildings and FacilitiesTHE 2015 IECC perscriptive table2015 IECC existing buildings:FOR EXISTING cEILINGS, WALLS OR FLOORS CAVITIES SEE SECTION 101.4.3EXCEPTION #3EXCEPTIONS: THE FOLLOWING NEED NOT COMPLY PROVIDED THE ENERGY USE OFTHE BUILIDING IS NOT INCREASED:3.EXISTING CEILING, WALL OR FLOOR CAVITIES EXPOSED DURINGCONTRUCTION PROVIDED THAT THESE CAVITIES ARE FILLED WITH INSULATIONFor local amendments see Ordinance 40-20161,000 sq ft vicinity map DH permit 5/7/19 W/D bui be w/h and ab built in storage new vanity and toiletnt Provide documentation that 1-hr dwelling separation and STD rating will be maintained bedrm #2 new bath layout w/barn door tub/ Provide engineer letter verifying that no structural walls are being removed exit exit newframingclose existing bath door remove exist'g wall remove exist'g wall mster bedrm bedrm #2 fireplace new bath layout w/barn door shwr tub/ shwr new bath layout w/barn door clstclst close existing bath door existing wood burning firebox no change replace existing stone veneer facade with new tile ext no change toexterior fenistration SCA 1 FI Provide documentation that1-hr dwelling separation and STD rating will be maintained