HomeMy WebLinkAboutFile Documents.802 W Main St.0170.2018 (3).ARBK0170-2018-ARBK_BuildingComments_2 Page: File Name: Architectural Plans.802 West Main.2018.08 (Comments2)-Bluebeam.pdf Subject: PlanCheck Author: nickt Color: Special inspection agreement must be signed by owner and fabricator. Architectural Plans.802 West Main.2018.08 (Comments2)-Bluebeam.pdf (10) Page: 3.6 MAIN FLOOR REFLECTED CEILING PLAN File Name: Architectural Plans.802 West Main.2018.08 (Comments2)-Bluebeam.pdf Subject: PlanCheck Author: nickt Color: What are the "P"s on the RCPs? Provide in a legend. Show the location of smoke alarms and carbon monoxide detectors on the RCPs or floor plans per 2015 IBC 907.2.11 and Municipal Code Title 8. The above comment was asked previously. Page: 3.8 TRASH ENCLOSURE File Name: Architectural Plans.802 West Main.2018.08 (Comments2)-Bluebeam.pdf Subject: PlanCheck Author: nickt Color: 2 yard dumpsters require the trash enclosure to be sprinklered or be of Type I or IIA construction. Type IIA requires the roof and bearing columns to be 1 hour fire rated (2015 IBC table 601). All components must be non-combustible except where allowed by 2015 IBC 603 (which allows wood framing in the roof). -Provide a listed assembly for the roof. -Columns must be 1 hour fire rated; fire retardant treated wood does not typically achieve this. -Demonstrate how the composite materials are non-combustible. The above comment was asked previously. You have provided only a listed wall assembly. Please complete the rest. Page: 5.3 BUILDING SECTIONS File Name: Architectural Plans.802 West Main.2018.08 (Comments2)-Bluebeam.pdf Subject: PlanCheck Author: nickt Color: Detail the fire partition continuity at this location. 2015 IBC 708.4 COA AFFOR Special inspection agreement must be signed by owner and fabricator. 8 9 10 11 12 13 14 15 16 17 18 12345678 UP RGRGRGRGRGRGRGRGRGRGRG RGRGRGRGRGRGRGRGRGRG DW DW 9'-07/8" A.F.F. 9'-07/8"A.F.F. 9'-07/8"A.F.F. 9'-07/8"A.F.F. 9'-07/8" A.F.F. 9'-01/8"A.F.F. 9'-01/8"A.F.F. 9'-01/8"A.F.F. 10'-41/8"A.F.F. 9'-07/8"A.F.F. 9'-07/8"A.F.F. 9'-07/8" A.F.F. 9'-07/8" A.F.F. 10'-41/8"A.F.F. 9'-07/8"A.F.F. 9'-07/8"A.F.F. 9'-07/8"A.F.F. 9'-07/8"A.F.F. 8'-07/8"A.F.F. 8'-07/8" A.F.F. 8'-07/8"A.F.F. 8'-07/8"A.F.F.8'-07/8"A.F.F. 8'-07/8" A.F.F. 9'-07/8"A.F.F. 9'-07/8"A.F.F. 8'-07/8"A.F.F. 8'-07/8" A.F.F. 8'-07/8"A.F.F. 8'-07/8"A.F.F.8'-07/8"A.F.F. 8'-07/8" A.F.F.8'-0A.F.F 8'-07/8"A.F.F. 8'-07/8" A.F.F. 8'-07/8" A.F.F. 8'-07/8" A.F.F. 9'-07/8" A.F.F. 16.2 5.6 (8) RECESSED LIGHT ENCLOSURES @ THE LIVING/DINING CEILING ONLY- (8) RECESSED LIGHT ENCLOSURES @ THE LIVING/DINING CEILING ONLY- W3 W3 W5 W5 W5 W3 W3 W3. 1 W3 W5 W3 W6. 1 W3 W3 W4 W6. 1 W3. 1 W5W5 W4 P P P P P PP P P P P P BEDROOM102-1 ENTRY102-0 BATHROOM102-4 KITCHEN102-3 CL. 102-7 CL. 102-8 LIVING ROOM102-2 BEDROOM101-1 ENTRY101-0 BATHROOM 101-4 KITCHEN101-3 CL. 101-7 CL. 101-8 LIVING ROOM101-2 BEDROOM 105-1 ENTRY105-0 BATHROOM 105-4 KITCHEN 105-3 CL. 105-7 CL.105-8 BEDROOM104-1 ENTRY104-0 BATHROOM104-4 KITCHEN104-3CL.104-7 CL. 104-8 DRDR W W W DR DR REF DR W REF RE F RE F W 19 20 21 22 23 24 25RG 1 A 3 7 109 11 14125 E J G H C 2 B 8 D F K L 1346 9'-07/8" A.F.F. 9'-07/8"A.F.F. 8'-07/8"A.F.F.8'-07/8"A.F.F. A5.1 B5.1 C5.2 D5.2 E5.3 H5.5 W3. 1 W3. 1 BEDROOM103-1 MUDROOM 103-5 ENTRY 103-0 CL. 103-7 CL. 103-6 BATHR 103 CL. A209 MUDROOM102-5 CL. 102-6 CL. 101-9 MUDROOM101-5 CL. 101-6 CL.105-9 MUDROOM 105-5 CL. 105-6 CL. 104-9 MUDROOM 104-5 CL.104-6 G5.5 What are the "P"s on the RCPs?Provide in a legend. Show the location of smoke alarms and carbon monoxidedetectors on the RCPs or floorplans per 2015 IBC 907.2.11 and Municipal Code Title 8. The above comment was asked previously. CO A A F F O R D A B L E H O U S I N G 80 2 W E S T M A I N S T . A S P E N , C O DRAWING ISSUE DRAWN BY:PROJECT No: 1702 PERMIT 06-14-18 CPF All ideas, designs, arrangements and plansindicated or represented by this drawing areowned by and are the property of David JohnstonArchitects, PC and developed for use and inconjunction with the specified project. Noneof the ideas, designs, arrangements or plansshall be used by or disclosed for any purposewhatsoever without the written authorizationof David Johnston Architects, PC. 119 South Spring St.Suite 203Aspen, CO 81611 970-925-3444 970-920-2186TELFAX 3.8 TRASH ENCLOSURE Sheet No. 2 2 1 1 A A C C B B 13.8 8'-6 " 1"7'-3"7'-3"1"14'-6" 6" 6" 1"6"6'-6"6"6'-6"6"1" 15'-0" 1'- 6 " 60" TURNING DIAMETER 2YD DUMPSTER 2YD DUMPSTER RECYCLING BINS EDGE OF ROOF EDGE OF ROOF EDG E O F R O O F ED G E O F R O O F A3.8 A3.833.8 23.843.8 13.8 C B A 1 2 A B C 2 1 6'-5 1/4" 8" 1'-41/4" NON COMBUSTABLEROOF ASSEMBLY NONCOMBUSTABLEWALL ASSEMBLYJH/FCS 60-01 NONCOMBUSTABLEMETAL COLUMNS R4 Division 07 – Thermal and Moisture Protection 07 46 00 Siding 07 46 46 Fiber-Cement Siding James Hardie Building Products JH/FCS 60-01 James Hardie Fiber Cement Siding ASTM E119, CAN/ULC S101 Non-Symmetrical, 1 Hour Non-Load-Bearing Wall Assembly (Rating applies to both sides) 1. STEEL STUDS: Min. 3-5/8 in. depth 20 GA (0.0359 in.) galvanized steel studs, spaced 24 in. on center (oc) max. 2. GYPSUM WALLBOARD, SIDE A: 5/8 in. Type X gypsum wallboard, oriented vertically and fastened with 1-1/4 in. Type S drywall screws, spaced 8 in. oc at board edges and 12 in. oc in field areas of the board. GYPSUM SHEATHING, SIDE B: 1/2 in. Type X or 5/8 in. Type X gypsum sheathing, oriented vertically with edge joints staggered from those of Side A, fastened with 1-1/4 in. Type S drywall screws spaced 24 in. oc. 3. WOOD SHEATHING (Optional): Install one layer of wood structural panel sheathing on or behind Item 2B. FURRING (Optional): xMin. 1-1/2 in. wide by 3/8 in. thick furring (Wood: Min. 0.42 s.g.; Metal: Corrosion Resistant min. 20 GA 33 ksi metal hat channel, z-girt or u-bar) or xMin. 4.574 in. wide by 3/4 in. thick James Hardie Horizontal Steel furring installed per manufacturer’s installation instructions (min. 18 GA 33 ksi metal). 4. CERTIFIED MANUFACTURER: James Hardie Building Products Inc. CERTIFIED PRODUCT: Titan, HardieBacker, HardiePanel Vertical Siding, Cempanel® Vertical Siding, Artisan® Lap Siding, Artisan® Siding with Lock Joint System, Pressed Hardie® Reveal™ Panel System, HardieReveal2.0™ Panel, Prevail Panel Siding, HardiePlank® Lap Siding, CemPlank® Lap Siding, and Prevail® Lap Siding. FIBRE CEMENT FACING, SIDE B: Min. 1/4 in. Titan (tapered edge) panel, HardieBacker (square edge) Backerboard, HardiePanel Vertical Siding, Cempanel® Vertical Siding, 7/16 in. thick Hardie® Reveal™ Panel System, 7/16 in. HardieReveal2.0™ Panel, 5/16 in. Prevail Panel Siding, or 5/16 in. HardiePlank® Lap Siding, 5/8 in. Artisan® Lap Siding, 5/8 in. Artisan® Siding with Lock Joint System, 5/16 in. CemPlank® Lap Siding, or 5/16 in. Prevail® Lap Siding applied vertically, with vertical edges staggered 24 in. from those of gypsum sheathing substrate. Panel, backerboard, or baseboard is fastened through gypsum sheathing to framing members with min. 1-5/8 in. long by 0.33 in. HD self-drilling ribbed bugle-head (or wafer-head) screws, located max. 8 in. oc. 0 1' 2' 4'SCALE: 1/2" = 1'-0"1 TRASH ENCLOSURE PLAN 0 1' 2' 4'SCALE: 1/2" = 1'-0"1 NORTH ELEVATION 0 1' 2' 4'SCALE: 1/2" = 1'-0"4 WEST ELEVATION 0 1' 2' 4'SCALE: 1/2" = 1'-0"3 SOUTH ELEVATION 0 1' 2' 4'SCALE: 1/2" = 1'-0"A BUILDING SECTION A 0 1' 2' 4'SCALE: 1/2" = 1'-0"2 EAST ELEVATION SCALE: 1:0.946NE PERSPECTIVE SCALE: 1:1.43BFire-Design-Listing-JH-FCS-60-01-1-hour 2 yard dumpsters require thetrash enclosure to be sprinkleredor be of Type I or IIAconstruction. Type IIA requiresthe roof and bearing columns tobe 1 hour fire rated (2015 IBCtable 601). All components mustbe non-combustible exceptwhere allowed by 2015 IBC 603(which allows wood framing inthe roof). -Provide a listed assembly forthe roof.-Columns must be 1 hour firerated; fire retardant treated wooddoes not typically achieve this.-Demonstrate how thecomposite materials arenon-combustible. The above comment was askedpreviously. You have providedonly a listed wall assembly.Please complete the rest. 1 7.3 3 7.6 3 OOM KITCHEN 3-1 202-3 W6 R3R2 W3 . 1 Detail the fire partition continuity at this location. 2015 IBC 708.4 3 See signed inspection agreement attached The P symbol is for a photoelectric smoke/CO combo detector. See the Abbreviations on the 1.0. The design for the trash enclosure has been revised. We used GA File # RC-2601 for the roof assembly and GA File # CM-1450 for the columns. The composite materials are the listed product in assembly B/3.8. See detail 4/7.6 for clarification. Detail has been called-out on section. 11/01/2018 Page: 5.5 BUILDING SECTIONS File Name: Architectural Plans.802 West Main.2018.08 (Comments2)-Bluebeam.pdf Subject: PlanCheck Author: nickt Color: Provide a callout to a detail at this location. Detail 3/7.6 conflicts with the roof framing plan which shows the roof joists spanning from grid K to grid G (bearing on the exterior wall. This wall must be a 1/2 hour fire partition protecting the egress balcony dead end travel condition. The wall must extend to the top of the roof sheathing (not possible with this structural configuration) or the wall must extend to the underside of a fire rated ceiling assembly. Coordinate with structural and provide detail callouts in section for clarity. 2015 IBC 708.4 Page: 6.1 WALL SECTIONS File Name: Architectural Plans.802 West Main.2018.08 (Comments2)-Bluebeam.pdf Subject: PlanCheck Author: nickt Color: Insulate the crawlspace walls now that they are part of the thermal envelope. See prescriptive R value requirements in 2015 IECC R402.1.2 Page: 7.6 ROOF ASSEMBLIES & DETAILS File Name: Architectural Plans.802 West Main.2018.08 (Comments2)-Bluebeam.pdf Subject: PlanCheck Author: nickt Color: For the 1/2 hour rated fire partition wall at detail 3/7.6 to terminate at the underside of the roof ceiling, both R3 and R2 need to also be minimum 1/2 hour fire rated. 8 9 10 11 12 13 14 15 167 2 7.3 SECOND LEVEL 110'-5" S 1 F5 F3 F1 BEDROOM BATHROOM KITCHEN LIVING ROOM BEDROOM BATHROOM KITCHEN LIVING ROOM 205-1 205-4 205-3 205-2 R2R3 W5 W1 W1 W5 W5 W8 Provide a callout to a detail at this location. Detail 3/7.6 conflicts with the roof framing plan which shows the roof joists spanning from grid K to grid G (bearing on the exterior wall. This wall must be a 1/2 hour fire partition protecting the egress balcony dead end travel condition. The wall must extend to the top of the roof sheathing (not possible with this structural configuration) or the wall must extend to the underside of a fire rated ceiling assembly. Coordinate with structural and provide detail callouts in section for clarity. 2015 IBC 708.4 BASEMENT/ FOUNDATIONS BASEME MAIN LEVEL 0" MAIN L 0" EXTERIOR SHEATHING SEALED TO FOUNDATION SEAL BOTTOM PLATE TO FOUNDATION Insulate the crawlspace walls now that they are part of the thermal envelope. See prescriptive R value requirements in 2015 IECC R402.1.2 5/ 8 " SE E S T R U C T . ALL/ROOF CONDITION W3 R23 W3.1 W3.2 For the 1/2 hour rated fire partition wall at detail 3/7.6 to terminate at the underside of the roof ceiling, both R3 and R2 need to also be minimum 1/2 hour fire rated. See detail 3/7.6 for clarification. Detail has been revised to show continuity to the roof sheathing. The structural drawings reflect this revision Walltype W2 shows exterior insulation at the foundation. This is the standard assembly for all foundation walls at the basebment and crawlspace. I have added the graphics to all sections. See detail 3/7.6 for clarification. Detail has been revised to show continuity to the roof sheathing. The structural drawings reflect this revision 11/01/2018 Page: G1.13 FIRE SEPERATION File Name: Architectural Plans.802 West Main.2018.08 (Comments2)-Bluebeam.pdf Subject: Group Author: nickt Color: My previous comment: This comment has not been addressed: Egress balcony must be 10' from lot line (2015 1021.4). Provide a 1 hour fire rated wall to protect it. The portion of the balcony within 10' of the lot line must also be 1 hour fire rated on the edge and underside. Let me elaborate: The egress balcony is within 10' of the property line (not permitted by 2015 IBC 1021.4). The portion of the balcony used for egress is greater than 10' away however the balcony as a whole is closer and is built of combustible construction. You could cut the balcony back but that would eliminate the unit's useful balcony area. Alternatively, you could protect the balcony with 1 hour fire rated construction (1 hr horizontal assembly) and wrap it up the side. Non-combustible decking. (Or extend the rated wall to protect the entire balcony and elminate or protect the opening). Page: G1.15 ACCESSIBILITY File Name: Architectural Plans.802 West Main.2018.08 (Comments2)-Bluebeam.pdf Subject: PlanCheck Author: nickt Color: You have provided the required 30" wide clearspace for forward approach to the side of the oven allowing the oven door to open. However, if you select a 30" base cabinet, you will need a filler strip to keep the adjacent countertop overhang from encroaching on the 30" clearspace. It would best to submit your cabinet shop drawings as a deferred submittal to verify compliance with kitchen dimension requirements. ICC A117.1-2009 section 1004.12.2.4. Page: G1.15 ACCESSIBILITY File Name: Architectural Plans.802 West Main.2018.08 (Comments2)-Bluebeam.pdf Subject: PlanCheck Author: nickt Color: Center line of sink to edge of adjacent countertop must be at least 24" Type B unit kitchen sinks must have the 30"x48" clearspace centered on the sink. Make this clear on the plans and dimension from centerline of sink to any walls or counters to the side. ICC A117.1-2009 section 1004.12.2.1. 1234567891011121314151617181920 UP DW DW RG DW DW DW 5'-1" W3 . 1 W3 W6W3 W5 W5 W5 W3.2 W5.2 W5 . 2 W3 W3 . 1 6 W6 . 1 W3 W3 W6 6 W5 . 2 W3.2 W W6 W6 W3. 1 W REF DR W 19 202122 2324 2526272829 3031 3233343536 1 A 3 7 109 11 14 15125 E J M G H C 2 B 8 D F K L 1346 DWDW DWDW WWWWWWW3.222222222WWWWWWW3.222222222 WWW666 DR W DWDW DWDW RGRGRGRGRGRGRGRGRGRG DW W REF My previous comment: This comment has not been addressed: Egress balcony must be 10' from lot line (2015 1021.4). Provide a 1 hour fire rated wall to protect it. The portion of the balcony within 10' of the lot line must also be 1 hour fire rated on the edge and underside. Let me elaborate: The egress balcony is within 10' of the property line (not permitted by 2015 IBC 1021.4). The portion of the balcony used for egress is greater than 10' away however the balcony as a whole is closer and is built of combustible construction. You could cut the balcony back but that would eliminate the unit's useful balcony area. Alternatively, you could protect the balcony with 1 hour fire rated construction (1 hr horizontal assembly) and wrap it up the side. Non-combustible decking. (Or extend the rated wall to protect the entire balcony and elminate or protect the opening). 10'-0" DW1'-1159/64" 2'- 6 " 60" CLR. FROM PROJECTING FINISH OR APPLIANCE CL CL DR W REF CLCLCL CL RG J M H K L 2'-05/8"1'-3" 5'- 1 " <- 5 0 " x 4 8 " 60 " x 5 6 " - > 30"x48" 56"x48 30"x48"<- 3 0 " x 4 8 " 30"x48" 30"x48" 30"x48" 1 BEDROOM UNIT ANSI A117.1-2009 TYPE B, OPTION A 32 " m a x . 38 " m i n . each side and mended to mount 24" long additional 2" min. bottom recom- standard grab bar 30 " m a x . p r e f e r r e d inimum Reinforcing Behind Toilets Located Beside a Wall You have provided the required 30" wide clearspace for forward approach to the side of the oven allowing the oven door to open. However, if you select a 30" base cabinet, you will need a filler strip to keep the adjacent countertop overhang from encroaching on the 30" clearspace. It would best to submit your cabinet shop drawings as a deferred submittal to verify compliance with kitchen dimension requirements. ICC A117.1-2009 section 1004.12.2.4. DW1'-1159/64" 2'- 6 " 60" CLR. FROM PROJECTIN FINISH OR APPLIA CL CL DR REF CLCLCL CL RG N M K L 2'-05/8"1' 5'- 1 " 30"x48" 56 30"x48"<- 3 0 " x 4 8 " 30"x48" 30"x48" 30"x48" 1 BEDROOM UNIT ANSI A117.1-2009 TYPE B, OPTION A Center line of sink to edge of adjacent countertop must be at least 24" Type B unit kitchen sinks must have the 30"x48" clearspace centered on the sink. Make this clear on the plans and dimension from centerline of sink to any walls or counters to the side. ICC A117.1-2009 section 1004.12.2.1. Assembly F5 and R3 is a 1 HR rated listed assembly. This centerline has been revised and is shown 2'-1" from the counter or wall. All kitchens have been revised to show the countertop overhang at 1". Furthermore we have left additional space for filler panels etc. We can show shop drawings at a later date if need be. 11/01/2018 Page: [8] C7 DRAINAGE PLAN File Name: Civil Plans.802 West Main.2018.10 (Comments2).pdf Subject: PlanCheck Author: nickt Color: The area between the sloped surface and flat surface creates a variable height step. Riser heights must be a minimum of 4". Any less than this becomes a tripping hazard. Eliminate step areas less than 4". 2015 IBC 1011.5.2 The above comment was asked previously. Civil Plans.802 West Main.2018.10 (Comments2).pdf (1) Page: 1 File Name: CoverSheet.pdf Subject: Group Author: nickt Color: CoverSheet.pdf (1) Page: 1 File Name: Special Inspection.802 West Main.2018.05.pdf Subject: PlanCheck Author: nickt Color: special inspection agreement must be signed by owner and fabricator Special Inspection.802 West Main.2018.05.pdf (1) G The area between the sloped surface and flat surface creates a variable height step. Riser heights must be a minimum of 4". Any less than this becomes a tripping hazard. Eliminate step areas less than 4". 2015 IBC 1011.5.2 The above comment was asked previously. FIRE SPRINKLERS REQUIRED NFPA 13 (not 13R) sprinkler system required throughout entire building to allow for reduced travel distance in basement storage (2015 IBC table 1006.3.2(2). David Johnston Architects D. Brian Beazley 04-20-18 special inspection agreement must be signed by owner and fabricator These signatures have been included on pages 2&3 in the attached PDF. This wall has been raised and shows as 28.76' which is 8 7/8" above the tallest walking surface. 11/01/2018