Loading...
HomeMy WebLinkAboutFile Documents.802 W Main St.0170.2018 (4).ARBK0170-2018-ARBK_BuildingComments_4 Page: File Name: Architectural Plans.802 West Main.2018.010-BLUEBEAM.pdf Subject: PlanCheck Author: nickt Color: The special inspection agreement must be signed by the owner. Architectural Plans.802 West Main.2018.010-BLUEBEAM.pdf (4) Page: 5.2 BUILDING SECTIONS File Name: Architectural Plans.802 West Main.2018.010-BLUEBEAM.pdf Subject: PlanCheck Author: nickt Color: Wrap the edge of the balcony at this location to protect the side of the F5 assembly from fire from the adjacent property (this is an egress balcony). (Egress balcony must be 10' from lot line (2015 1021.4). The portion of the balcony within 10' of the lot line must also be 1 hour fire rated on the edge and underside). Page: 7.6 ROOF ASSEMBLIES & DETAILS File Name: Architectural Plans.802 West Main.2018.010-BLUEBEAM.pdf Subject: PlanCheck Author: nickt Color: In this location the joists do indeed run parallel to the wall, however there are 4 pack LVL beams that run perpendicular and must penetrate the membrane. Perhaps the APA rim board detail would work here? Page: G1.15 ACCESSIBILITY File Name: Architectural Plans.802 West Main.2018.010-BLUEBEAM.pdf Subject: PlanCheck Author: nickt Color: The 30" dimension is no longer aligned with the oven clearspace. NG 802 WEST MAIN ST The special inspection agreement must be signed by the owner. SECOND LEVEL 110'-5" Wrap the edge of the balcony at this location to protect the side of the F5 assembly from fire from the adjacent property (this is an egress balcony). (Egress balcony must be 10' from lot line (2015 1021.4). The portion of the balcony within 10' of the lot line must also be 1 hour fire rated on the edge and underside). 5/ 8 " 11 7/ 8 " 3 / 4 " 3" TYPICAL SL FIRE-RATED WALL/ROOF CONDITION T. O. SHEATHING SEE PLAN GL FIRE SEPARATION CONTINUES TO UNDERSIDE OF ROOF SHEATHING @ RATED WALLS AIRSEAL SOFFIT TO SHEATHING R2 W4 W6 In this location the joists do indeed run parallel to the wall, however there are 4 pack LVL beams that run perpendicular and must penetrate the membrane. Perhaps the APA rim board detail would work here? DW 2'-1" 2'- 6 " CL REF 2'-1"2'-1" CL RG K L 5' - 1 " 30"x48"<- 3 0 " x 4 8 " 30"x48 1 B AN TY The 30" dimension is no longer aligned with the oven clearspace. See the attached signed Special Inspection Form attached. Detail 4/7.3 shows protection on the side of the F5 assembly. We have revised the detail to show an APA rim joist. This condition applies for both detail 4&6/7.6. Detail 2/S3.3 coordinates with these details. The dimension has been moved to align with the oven clearspace. 12/06/2018