Loading...
HomeMy WebLinkAboutFile Documents.754 Moore Dr.0193.2019 (29).ARBK0193.2019.ARBK_Zoning_2 Page: E1.1 - Supplemental Info Checkmark: Unchecked Author: jimp File Name: 754 Moore Dr - Electrical Supp Info Drawings_2020-02-06.pdf Please provide details on address lighting. Please note, all address markers must meet current City of Aspen outdoor lighting standards, including - being fully shielded and no back lit signs. 754 Moore Dr - Electrical Supp Info Drawings_2020-02-06.pdf (1) Page: L6-01 - Supplemental Info Checkmark: Unchecked Author: jimp File Name: 754 Moore Dr - Landscape Supp Info Drawings_2020-02-06.pdf Per the the City of Aspen Outdoor Lighting standards - 26.26.575.150.I, linear lighting is prohibited throughout the City. Please provide a different light for the address marker that meets both the Outdoor Lighting Code as well as the lighting standards in the Sign Code. 754 Moore Dr - Landscape Supp Info Drawings_2020-02-06.pdf (2) Page: L7-10 - Supplemental Info Checkmark: Unchecked Author: jimp File Name: 754 Moore Dr - Landscape Supp Info Drawings_2020-02-06.pdf Per the the City of Aspen Outdoor Lighting standards - 26.26.575.150.I, linear lighting is prohibited throughout the City. Please provide a different light for the address marker that meets both the Outdoor Lighting Code as well as the lighting standards in the Sign Code. J PROVIDE 20A, 120V POWER FOR ADDRESS MARKER LIGHTING. CONTRACTOR SHALL CONFIRM POWER REQUIREMENTS WITH REVIEWED MARKER LIGHTING SUBMITTAL PRIOR TO ROUGH-IN. PROVIDE (1) 1" CONDUIT FROM PANEL 'L1'. CONTRACTOR SHALL CONFIRM EXACT LOCATION OF ADDRESS MARKER LIGHTING PRIOR TO ROUGH-IN. P2-16P2-16 Please provide details on address lighting. Please note, all address markers must meet current City of Aspen outdoor lighting standards, including - being fully shielded and no back lit signs. X-UEW W W W SSSSSSSSSSSSSSSSSS CTV CTV CTV T T T EX-UE EX-UE EX-UE CTV CTV G 1 Pool Light (See Pool Drawings). 2 Spa Light (See Spa Drawings). 3 Trees to be illuminated with holiday lighting. Circuitry by others. See MEP Dwgs. 4 Landscape boxes for lighting drivers. Circuitry by others. See MEP Dwgs. 5 Wall mounted outlet with weather proof cover. See MEP Dwgs. 6 LED strip lights to illuminate the address lettering. 18 YP) Per the the City of Aspen Outdoor Lighting standards - 26.26.575.150.I, linear lighting is prohibited throughout the City. Please provide a different light for the address marker that meets both the Outdoor Lighting Code as well as the lighting standards in the Sign Code. A B C D E 1 2 3 4 5 6 7 8 SITE KEYNOTES: 1.0 PAVEMENTS, RAMPS, CURBS 1.1 Concrete Paving Type 1 - Snowmelt 2.0 JOINTING 2.1 Control Joint2.2 Expansion Joint 3.0 STEPS 3.1 4.0 SITE WALLS/ EMBANKMENTS 4.1 Concrete Wall Type 24.2 5.0 SITE FURNITURE NOT USED AT THIS TIME 6.0 RAILINGS, BARRIERS, FENCING 6.1 Cable Railing 7.0 SITE LIGHTING 8.0 DRAINAGE 8.1 Landscape Area Drain 9.0 PLANTING AND LANDSCAPE Refer to planting series drawings 10.0 MISCELLANEOUS ELEMENTS 10.1 Fire Feature 1.3 2.4 Stone Wall Cap Joint 10.210.3 Custom Grill 1.6 Pool and Spa Coping Type 1 Pool and Spa Coping Type 3 Stone Steps 2.3 8.2 Hardscape Area Drain Entry Marker 1.4 Pool and Spa Coping Type 2 Stone Paving Type 1 1.7 Concrete Wall Type 1 Reinforced Turf 1.8 2.5 Not used at this time 10.4 Pool Umbrella 8.3 Slot Drain 6.2 Fence6.3 Not Used at this Time 1.5 Stone Paving Type 2 - Snowmelt Stone Paving Joint Concrete Wall Type 34.3 10.5 Raised Tree Planter10.6 Snowmelt Manifold Access Hatch 1.2 Concrete Paving Type 2 - Snowmelt 7.1 Wall Light7.2 Sconce Light 6.4 Ski Access Gate6.5 Not Used at this Time Not Used at this Time1.9 1 ENTRY MARKER1" = 1' - 0" 10.3 PLAN ELEVATION A ELEVATION B STONE VENEER STONE VENEER STONE VENEER 1'-6 " 5'-0" 3'-6 " 5'-0" 1'-6" 3'-6 "12" METAL PLATE BELOWLETTERING, POWDERCOATED (ANCHOR TOCONCRETE) LINE OF CONCRETE CORE(BELOW) 12" METAL PLATE BELOW LETTERING, POWDERCOATED (ANCHOR TO CONCRETE) 4" 134" 3'-9" 1'-6" 3'-6 " MIN . FILTER FABRICCLEAN CRUSHED AGGREGATE 4" DIA. PERFORATED PIPE: ASREQUIRED BY CIVIL. SECTION 4" POURED-IN-PLACE, 8"CONCRETE WALL REINFORCEDW / #5@12" O.C., EW,CENTERED PITCH 4" M I N . 3'-6 " PITCH STONE VENEER DRAINAGE BOARDMORTAR SETTING BED ADJACENT SURFACE(SEE PLAN) CONTINUE GALVANIZED L 4" X4" X 14", ATTACH TO WALL W /1/2" DIA. EXPANSION ANCHORS@ 24" O.C., (3) MIN; 3" EMBED COMPACTED SUBGRADE 4" M I N . 6" 1" METAL LETTERING, POWDER COATED, TYP 4" EL E V A T I O N B ELEVATION A 1" 6" ANCHOR FOR 12" METAL PLATE 1" DOWEL TO MATCH VERTICALREINFORCEMENT10 " 16" W x 10" D CONCRETEFOOTING W / (3)#5 HORIZONTAL 6" 12" METAL PLATE BELOWLETTERING, POWDERCOATED (ANCHOR TOCONCRETE ) 112" CRUSHED COMPACTED AGGREGATE BASE METAL LETTERING,POWDER COATED, TYP STONE CAPCOPPER FLASHING 2" 12" STEEL PLATE, POWDER COATED,WITH EMBEDDED LED STRIP LIGHT,DOWNCAST (CIRCUITRY BY OTHERS) 1" 2" 2" METAL LETTERING,POWDER COATED, TYP 1'-334"114"114" AREA OF LED STRIP LIGHTS, TYP12" METAL PLATE ABOVE LETTERING, POWDERCOATED (ANCHOR TO CONCRETE) 4" 112" 12" STEEL PLATE, POWDER COATED(ANCHOR TO CONCRETE) 112"114"114" 114" 114" 4" 112" 2" ALIGN END OF TOP METALPLATE WITH END OF NUMBER 12" METAL PLATE ABOVELETTERING, POWDERCOATED WITHEMBEDDED LED STRIP(ANCHOR TO CONCRETE;CIRCUITRY BY OTHERS) METAL LETTERING,POWDER COATED, TYP AREA OF LED STRIPLIGHTS, TYP 112" 112" 6"6" 2" 12" METAL PLATE ABOVELETTERING, POWDER COATEDWITH EMBEDDED LED STRIP(ANCHOR TO CONCRETE;CIRCUITRY BY OTHERS) AREA OF LED STRIPLIGHTS, TYP PLAN VIEW REFER TO MANUFACTURER'SINSTRUCTIONS FOR COREBORE DRILL PATTERN FLUSH MOUNT (REFER TO EXTENSION POLEUMBRELLA MAST FLUSH MOUNT HINGED COVER W/ HITCH PIN 18 Per the the City of Aspen Outdoor Lightingstandards - 26.26.575.150.I, linear lighting isprohibited throughout the City. Please providea different light for the address marker thatmeets both the Outdoor Lighting Code as wellas the lighting standards in the Sign Code.