Loading...
HomeMy WebLinkAboutFile Documents.754 Moore Dr.0193.2019 (34).ARBK0193-2019-ARBK_BuildingComments_2 Subject: PlanCheck Page: L3-02 - Supplemental Info Page Index: 3 Author: nickt Color: File Name: 754 Moore Dr - Landscape Supp Info Drawings_2020-02-06.pdf Install with clearances per manufacturer's instructions. 754 Moore Dr - Landscape Supp Info Drawings_2020-02-06.pdf (4) Subject: PlanCheck Page: L3-02 - Supplemental Info Page Index: 3 Author: nickt Color: File Name: 754 Moore Dr - Landscape Supp Info Drawings_2020-02-06.pdf Handrails required. 2015 IRC R311.7.8 Subject: PlanCheck Page: L4-02 - Supplemental Info Page Index: 5 Author: nickt Color: File Name: 754 Moore Dr - Landscape Supp Info Drawings_2020-02-06.pdf Provide handrails at all stairs with more than 3 risers. 2015 IRC R311.7.8 Subject: PlanCheck Page: L7-08 - Supplemental Info Page Index: 13 Author: nickt Color: File Name: 754 Moore Dr - Landscape Supp Info Drawings_2020-02-06.pdf Must comply with manufacturer's installation instructions, including clearances to combustibles and structure. H L MAIN HOME 4 1.3TYP. PA TYP. 10.1 TYP. 1.4 8.3 15 Install with clearances per manufacturer's instructions. G G G G G G L L H H H L L L L L PROPER T Y L I N E NT (TYP ) MAIN HOME BUILDIN G E N V E L O P E ( T Y P ) L7-12 3 PA PA PA PA 2 P. 4 6 1.3TYP. PA 10.5 8.3 TYP. 10.1 TYP. 10.2 TYP. .1 TYP. 8 8 1.4 3.1 11 10.4 PA PA 3.1 15 15 Handrails required. 2015 IRC R311.7.8 L L H H H L L L L L EQ. 10.00' EQ. 6.90' 9 . 2 8 ' 21.25' 6.37' 5 . 0 0 ' 2. 0 3 ' 10.64' 10.62' 2' 7 . 2 9 ' EQ F O R 4 2 . 6 5 ' E Q FO R 2 EQFO R 4 EQ F O R 3 6. 6 3 ' 2.00' PROPER T Y L I N E ( T Y P . ) YP) ) 2 OF WOR K ( T Y P ) 15 15 15 15 15 Provide handrails at all stairs with more than 3 risers. 2015 IRC R311.7.8 3 4 5 6 7 8 9 10.6 Snowmelt Manifold Access Hatch 3 / L7-11 10.1 C ELEVATION (A) 1'6"1' 2' STONE VENEER (PATTERN TO BE DETERMINED) STONE VENEER TOPPLATE (4" THICK) GAS FLANGE AND DECORATIVE BLACK KEYVALVE. CONNECT TO BURNER CONTROLS. ELECTRIC STARTER AND ENCLOSURE BOX.RECESS INTO STONE VENEER. TIE IN PERMANUFACTURER. LINE OF STONE VENEER (BEYOND) LINE OF CONCRETE CORE (BEYOND) METAL ANGLE. (TYP) BURNER INSERT TRAY ROCK INFILL. (TYP) ELECTRICAL JUNCTION BOX BELOW. (WATER PROOF) BURNER CONTROL BOX (PROVIDE X" GAS LINE SUPPLY TO) LINE OF CONCRETE BELOW 11 " 8" 11 " P. 1.2 2'- 0 " TYP.1.2 STONE VENEER (4" THICK) FLOOR DRAIN. CONNECT TO STORM DRAIN SYSTEM (PER CIVIL DWGS) FOOTING AS REQUIRED (SEE STRUCTURAL DWGS.) 12" EXPANSION BOARD CAST-IN-PLACE CONCRETE SUBSLAB PER STRUCTURAL METAL ANGLE AS REQUIRED TO SUPPORT MESH TRAY. (TYP) METAL SUPPORT ANGLE DRAINAGE BOARD MORTAR SETTING BED SECTION (B) 1.2 412" 7" 912" 4"MIN . 8'-6" 6'-8"11" TYP) RT TRAY BURNER CONTROL BOX. CONNECT TO GAS AND ELECTRIC PERMANUFACTURER AND MEP.REQUIREMENTS. VENT BLOCK-OUT THRU. CONC. SEE VENT ENLARGEMENT FOR DETAILED LOUVER PENETRATIONS. METAL MESH TRAYSUPPORTED BY ANGLE IRON.METAL ANGLE AS REQUIRED TO SUPPORT MESH TRAY. (TYP) TYP. CONDUIT FOR ELECTRICAL SERVICE GAS SERVICE LINE. COORDINATE PER MEP. 412" 7" 6" TYP. 12" T Y P . 12" T Y P . VENT BLOCK-OUT THRU. CONC. SHOWN HERE FOR LOCATION REF. WATER JET OR SIMILARPRECISION CUT THRU. HOLES AT(2) VENT LOCATIONS ON ONE SIDEPANEL OF STONE VENEER. VENTS TO FACE AWAY FROM HOME. VENT THRU. HOLES ENLARGEMENT SCALE: 3" = 1'-00" CONCRETE PER STRUCTURAL 15 NOTE: FIRE FEATURE TO BE DESIGN BUILD TO ACCOMMODATE A REQUEST FOR REDUCED HEIGHT TO 18 INCHES. 18 Must comply withmanufacturer's installation instructions, including clearances tocombustibles and structure.