Loading...
HomeMy WebLinkAboutFile Documents.134 Maple Ln.0138.2019 (29).ARBKAl Beyer Design Inc. 410 N. Mill B-11 • Aspen, CO 81611 Phone 970.925.8339 • Fax 970.925.8392 Any dimensional descrepancy shall be brought commencement of work. All designs, ideas, arrangements and plans indicated by these drawings and specifications are the property and copyright of the Architect and shall neither be used on any other work nor be used by any other person for any use whatsoever without written permission. Written dimensions shall take precedence over scaled to the attention of the Architect prior to dimensions and shall be verifyed at the job site. CHECKED BY: REVISIONS ISSUE DATE: DRAWN BY: PROJECT NUMBER SHEET TITLE AND NUMBER AB/BK Jenny+James 04/11/19 Prelim Zoning + Smuggler 134 Maple Lane Aspen CO 81611 SITE PLAN A1 PID: 273707490134 Hamilton+Foerster 04/04/19 764 sq ft LOT 134 3470 SQ. FT. S TOP OF YPC = 7923.52 BENCH MARK TRANSFERED FROM CITY GPS POINT NO. 4 7 9 2 5 79 2 4 7 9 2 5 79 2 3 79 2 3 79 2 4 79 2 5 79 2 6 79 2 7 79 2 9 79 3 0 79 3 1 79 3 2 79 2 8 7930 7927 7932 7929 79 2 6 79 2 3 79 2 5 7932 79 2 6 A B D C 1 2 3 4 1 2 3 4 A B D C E x i s t i n g P e d e s t r i a n E a s e m e n t - s i d e w a l k Existing Floor Level = 100'-0 = 7926.75 Deck Garage T.O. ENTRY SLAB 97'-3 1/2" T.O. EXISTING SLAB 96'-9 1/2" 100'-0" T.O. PLY T.O. PLY 101'-2" Existing Shed Denotes ext. lighting = 4" d. recessed LED Elco #1499 (3) in LR soffit (1) in entry soffit 0 ' F R O N T Y A R D S E T B A C K 0' FRONT YARD SETBACK 5' R E A R Y A R D S E T B A C K 10' OTHER SIDE SETBA C K EXISTING BUILDING TO REMAIN REPLACEMENT + NEW CONSTRUCTION SHOWN w/ SQUARE HATCHING 91'-6" = 7918.25 T.O. SLABBASEMENT LEVEL Lightwell Mid Pt of Roof =7939.25 max. Lowest grade @ Mid Point = 7924.25± Project Mid. Pt. =7938.25 ± (1' lower than allowable) EXISTING EXISTING 3:12 1/2:12 Existing Membrane roof NEW Membrane roof 1/2±:12 3:12 1/2:121/2:12 1/2:12 Sidewalk Topo information taken from Hired Gun Survey LANDSCAPING NOTES: -Restore Site to pre construction vegetation or better -Preserve all existing trees and bushes -Limit Site disturbance and keep it looking good -No sprinkler system planned -Reseed with PitCo approved seed mix N E W S Materials storage in Garage and on existing Roof EXISTING EXISTING NEW PORCH ROOF 15 ' 1' - 6 1 / 2 " 13 ' - 5 1 / 2 " 10' 6'6' 13 ' - 3 3 / 4 " ABDC NEW METAL SIDING "BMP BOAT" average grade line = 98'-5 1/2" = 7,925.2' Max Roof line = 7,940.2 = 113'-5 1/2 Existing Floor = 7,926.75 = 100'-0 12' "standard roof" eave line existing LVL roof to remain Setback Line Existing trees preserved NOTE: Roof ht. is calculated by Smuggler Park based on 15' above average site grade (those lines shown here)City of Aspen measures 15' to midpoint of 3:12 sloped roof which the original and current projects easily stay within Lowest Grade @ Bldg =7924.25 Max. Mid Pt. Elev. =7939.25 Project midpoint El = 7938.2 312 3 12 Pr o p e r t y L i n e MI D . P O I N T MI D . P O I N T H t . Field Verify Stairs/Handrail per code No limit to ridge Ht. per City Code. sill = 107'-11 1/2" NEW ROOF Max. Height = 12'-4 NEW WOOD SIDING SCALE: 3/16" = 1'-0" 2 SITE PLAN A1 SCALE: 3/16" = 1'-0" 3 BUILDING HEIGHT West A1 08/29/2019 Al Beyer Design Inc. 410 N. Mill B-11 • Aspen, CO 81611 Phone 970.925.8339 • Fax 970.925.8392 Any dimensional descrepancy shall be brought commencement of work. All designs, ideas, arrangements and plans indicated by these drawings and specifications are the property and copyright of the Architect and shall neither be used on any other work nor be used by any other person for any use whatsoever without written permission. Written dimensions shall take precedence over scaled to the attention of the Architect prior to dimensions and shall be verifyed at the job site. CHECKED BY: REVISIONS ISSUE DATE: DRAWN BY: PROJECT NUMBER SHEET TITLE AND NUMBER AB/BK Jenny+James 04/11/19 Prelim Zoning + Smuggler 134 Maple Lane Aspen CO 81611 LOWER/FOUND. A2 PID: 273707490134 Hamilton+Foerster 04/04/19 2-6 3/4x5-1/22-6 3/4x5-1/2 3- 3 / 4 x 4 - 6 1 / 2 16 ' 8' 22 ' 14'12'12' 16 ' 8' 4' 3' - 4 " 7'-4" 14'12'12' 3' 81/4"5'-3/4"11" 16 ' 6' - 8 " 6'-4"10'4' 6'-8" 51/2"3"3'-2"31/2"5'-2"8" 16'-8" 23'-4"8" 51/ 2 " 11 ' - 6 1/ 2 " 8" 4' 31/ 2 " 1' - 1 1 1/ 2 " 2' - 1 0 " 2' - 9 " 6" 2'-4"21'7'-53/4" 6'-6"5'-6"8'-10"8" 7'-6 1/16" 2'-4" 4'-7 1/2" 41/ 1 6 " 8 " 1 0 ' - 3 " 5'-7/8" 1' - 1 0 15 / 1 6 " 4' - 8 " 3334 3130 35 32 D30 40 41 42 A B D C 1 2 3 4 1 2 3 4 A B D C Up 91'-8" T.O. SLAB Existing Crawl Space Bathroom Egress Lightwell Stairwell Up Access Door BR#2 Rec Room Provide egress ladders rungs = 12" o.c. vert max. width = 16" min. Handrail @ + 34"-38" SG 91'-7±" T.O. DECK SUMP Open below stairs Boiler HW Zone Valves + pumps Maximize Bath Width Field Verify vs Existing Access Opening Location Or i g i n a l F o o t p r i n t 91'-8" T.O. SLAB BR #3 GARAGE ABOVE SLAB ON GRADE Dropped 9 1/2" LVL's slip into Existing Beam Ends N e w T H I C K E N E D S L A B E D G E F N D . NEW BASEMENT EXISTING BASEMENT Lightwell TOW 96'-6 TOF 91'-2 TOW 99' -9 1/2 TOF 97'-2 ALIGN Original Footprint Cantilevered Floor Above TOW 99' -9 1/2 TOF 95'-2± 1 1 2 2 1a 1a 3 3 2-8 3/4x4-6 1/2 2-8 3/4x4-6 1/2 6-3/4x2-1/22-8 3/4x2-1/2 5- 3 / 4 x 2 - 1 / 2 3-3/4x5-6 1/2 14'12'12' 14'12'12' 16 ' 3130 35 32 D30 1 2 3 4 1 2 3 4 Existing Crawl Space Existing Fnd Piers not shown Lightwell Stairwell Up Provide egress ladders rungs = 12" o.c. vert max. width = 16" min. Handrail @ + 34"-38" SG 91'-7±" T.O. DECK Crawl Space Boiler HW Zone Valves + pumps Or i g i n a l F o o t p r i n t GARAGE ABOVE SLAB ON GRADE Original Footprint 2 2 3 3 SCALE: 1/4" = 1'-0" 2 -1. Basement Plan A2 SCALE: 1/4" = 1'-0" 3 Existing Basement A2 08/29/2019 Al Beyer Design Inc. 410 N. Mill B-11 • Aspen, CO 81611 Phone 970.925.8339 • Fax 970.925.8392 Any dimensional descrepancy shall be brought commencement of work. All designs, ideas, arrangements and plans indicated by these drawings and specifications are the property and copyright of the Architect and shall neither be used on any other work nor be used by any other person for any use whatsoever without written permission. Written dimensions shall take precedence over scaled to the attention of the Architect prior to dimensions and shall be verifyed at the job site. CHECKED BY: REVISIONS ISSUE DATE: DRAWN BY: PROJECT NUMBER SHEET TITLE AND NUMBER AB/BK Jenny+James 04/11/19 Prelim Zoning + Smuggler 134 Maple Lane Aspen CO 81611 MAIN A3 PID: 273707490134 Hamilton+Foerster 04/04/19 2-6x5-6 2-10x1-6 1-8 3/4x4-0 8 - 0 x 2 - 5 5-0x2-6 4-0x3-11 1/4 RG F 16 ' 8' 22 ' 14'12'12'6'-91/2" 14'12'12' 16 ' 51/ 2 " 7' - 4 " 14 ' - 3 13 / 1 6 " 1' - 1/ 4 " 23 ' - 8 11 / 1 6 " 5 ' - 9 3 / 4 " 3 1 / 2 " 9 ' - 9 1 / 2 " 5 1 / 2 " 2 ' - 9 " 3 ' - 3 / 4 " 3 1 / 2 " 4'-93/16"3 1/2"4'-1 3/8"3 1/2"5'31/2"1'-4" 4'-93/16" 10'5 1/2" 1 1/2" 1'-8 3/4" 4 " 1 4 ' 30'-11 1/2" 19'-5 1/2"5 1 / 2 " 1 5 ' - 1 0 3 / 4 " 5 1 / 2 " 4'-21/8" 7' - 3 " 23/4"23/4"3'-11"31/2" 2"6'-6"51/2" 5'-2"2'-6"3"2'-10"7"2'-5 1/16"1'-3 3/16" 1 0 ' - 1 1 / 4 " 6 ' - 8 1 / 2 " 2'-10"3" 3 ' - 1 1 / 4 " 3 1 / 2 " 5.10° 78.11° 57.07° 90.00° 1 1 2 2 1a 1a 3 3 04 030102 D01 25 05 101'-2" T.O. PLY LIVING 101'-2 3/4" T.O. FF MUDROOM BATH A B D C 1 2 3 4 1 2 3 4 A B D C Down Bench WASHER DRYER Pantry DW BIKES WOODSTOVE Down Pantry N E W S LIGHTWELL GARAGE CLOSET CLOSET OFFICE KITCHEN DINING ENTRY PORCH RR T i e W a l l CLOSET 97'-3 1/2" T.O. Conc. 5' R E A R Y A R D S E T B A C K 10' OTHER SIDE SETBA C K Up Existing Floor Level 100'-0 = 7926.75 Top of Ply = 101'-2 = 7927.91 2R @ 7.5"- 101'-2" T.O. PLY 100'-0" T.O. PLY Fan min. parking space Floor Step 96'-9 1/2" T.O. Conc. SG SG SG SINK Linen CO # 1 -Entry Door swap w/ window -Bathroom fixtures rearranged (same ECU count) -MBR door shifted, new window - Mech equipment moved into Crawl Space -laundry to garage 18"-24" EX I S T I N G F e n c e Gate MBR LIGHTWELL Al i g n w / E x i s t i n g W a l l New Doors NORTH WALL PARALLELS P R O P E R T Y L I N E . F A C E O F F R A M I N G I S S E T B A C K 4 " VERIFY NICHES 3- 3 / 4 x 6 - 1 / 2 2-6x2-4 8-3/4x6-6 1/26-3/4x6-6 1/2 3-1x2-6 1/2 4 - 4 x 2 - 8 2-8x4-0 7- 1 / 2 x 3 - 8 1 / 2 2-6x2-4 2- 6 x 3 - 6 5-3/4x2-6 1/2 3- 3 / 4 x 2 - 1 / 2 5-3/4x2-1/2 RG F 16 ' 8' 22 ' 14'12'12'6'-9 1/2" 14'12'12' 5 1 / 2 " 7' - 4 " 14 ' - 3 3 / 4 " 1' - 1 / 4 " 23 ' - 8 3 / 4 " 1' - 1 1 / 2 " 4 " 1 4 ' 30'-11 1/2" 19'-5 1/2" 4'-2" 7' - 3 " 2 3/4"2 3/4"3'-11"3 1/2"2"6'-6"5 1/2" 5° 90° 1 2 2 1a 3 3 04 54 030102 D01 5 5 25 53 52 05 101'-2" T.O. PLY LIVING 101'-2 3/4" T.O. FF MUDROOM BATH A B D C 1 2 3 4 1 2 3 4 Down WASHER DRYER Pantry DW BIKES WOODSTOVE Down MBR Pantry BR #1 N E W S LIGHTWELL GARAGE CLOSET CLOSET OFFICE SHED KITCHEN DINING ENTRY PORCH Walls to be removed are shown shaded CLOSET 97'-3 1/2" T.O. Conc. 5' R E A R Y A R D S E T B A C K 10' OTHER SIDE SETBA C K Up Existing Floor Level 100'-0 = 7926.75 Top of Ply = 101'-2 = 7927.91 2R @ 7.5"- 101'-2" T.O. PLY 100'-0" T.O. PLY Fan min. parking space Floor Step 96'-9 1/2" T.O. Conc. SG SG SG SINK Linen 18"-24" Gate LIGHTWELL Al i g n w / E x i s t i n g W a l l New Doors NORTH WALL PARALLELS P R O P E R T Y L I N E . F A C E O F F R A M I N G I S S E T B A C K 4 " VERIFY NICHES SCALE: 1/4" = 1'-0" 1 1. Main A3 SCALE: 1/4" = 1'-0" 5 Existing Plan A3 08/29/2019 Al Beyer Design Inc. 410 N. Mill B-11 • Aspen, CO 81611 Phone 970.925.8339 • Fax 970.925.8392 Any dimensional descrepancy shall be brought commencement of work. All designs, ideas, arrangements and plans indicated by these drawings and specifications are the property and copyright of the Architect and shall neither be used on any other work nor be used by any other person for any use whatsoever without written permission. Written dimensions shall take precedence over scaled to the attention of the Architect prior to dimensions and shall be verifyed at the job site. CHECKED BY: REVISIONS ISSUE DATE: DRAWN BY: PROJECT NUMBER SHEET TITLE AND NUMBER AB/BK Jenny+James 04/11/19 Prelim Zoning + Smuggler 134 Maple Lane Aspen CO 81611 ROOF A4 PID: 273707490134 Hamilton+Foerster 04/04/19 7- 1 / 2 x 2 - 9 250 sq ft 112 sq ft 55 sq ft 1 1 2 2 1a 1a 3 3 16 ' 8' 22 ' 14'12'12' 1'-4 Min. 30 ' m i n . 17'-4"6'-8" 17'-6"6'-6" 7' - 1 / 2 " 7 3 / 4 " 2'5'-5 3/4" 2'7'-10 3/4" 2'-5 1/4"5'-6" 5'-9 1/4" 2' 1'-1 1/4" 45° 60° 96° 66° 20 24 212322 A B D C 1 2 3 4 1 2 3 4 A B D C 3:12 1/2:12 NEW Membrane roof 1/2±:12 3:12 WQCV WEST: "BMP BOAT" below drip line + gutter/downspout for areas beyond drip access to remain with increased capacity as req'd by new calcs. Was 1056sf Draining to west, now with roof pitch change and additions Roof Area Draining to West = 1,779sf (88.9% of Total Drainage) WQCV EAST: Drip line flow to existing Bio-retention ditch w/ overflow in Yard. Conifer Canopy Conifer Canopy Deciduous Canopy Lot area = 3470 sf Impervious Area = 2,002.4 sf WQCV calculation Effective impervious Area = 2,002.4 - 362 (0.3) - 55(0.15) = 1885.6 Imperviousness = 54.34% WQCV = 0.105 watershed-inches 0.105 x 1/12 x 3,470 = 30.36 cf BMP west = .89 x 30.36 = 26.97 cf (201.8 gals) of WQCV in BMP Boat Increase existing BMP by 82 gallons or replace w/ larger BMP BOAT BMP east = .11 x 30.36 = 3.34 cf (25 gallons) of WQCV in ditch Ditch was designed and built to receive 74 Gallons so OK to leave as is was 419 SF ROOF AREA, Now 224 SF 16' long canoe x 2' avg width x 10.125" WQCV depth = 27 cf fill canoe to within 10.2" of lowest (extended) rim w/ sand/soil premix over filter fabric over 4" gravel w/ perf drain pipe to outlet. use valve at outlet as orifice control to retain WQCV for 12 hours. Alternative BMP Boats may be used to accomplish the same results. Verify Volume Calculations and assemblies of alternative BMP Boats. Pipe outlet and rim overflow runs onto/over existing grass swale buffer zone then into Smuggler collector system in Maple Lane D r a i n a g e 1:12 EX I S T I N G B u t t e r fl y R o of w / c e n t e r C r i c k e t Upper wall windows Membrane Roof BMP BOAT Sl o p e d B e a m p e r s t r u c t . Velux 2222 VCM U= .60 Max. Laminated glazing w/ min. .015" butyral inner layer overflow swale to tree well area Ex i s t i n g D r a i n a g e B M P p e r o r i g i n a l p e r m i t No w s e r v e s a s m a l l e r R o o f A r e a s o n o c h a n g e s r e q ' d low point/outlet for overflow ro o f d r a i n s t o y a r d , sh e e t fl o w t o b i o - r e t e n t i o n d i t c h M a i n t a i n e x i s t i n g s h e e t f l o w t o c u r b Roof drainage drops into BMP Boat Position BMP Boat to ensure all water from roofs is collected in the BMP Boat. add gutters or roof diverters as req'd. Field verify all systems work as planned or better Roof slopes to west RO O F P I T C H S Q U A R E TO 6 0 ° S P R I N G P O I N T Roof slopes to west 3.7 5 : 1 2 V A L L E Y NEW ROOF FRAMING OVER FRAME ROOF TO ALIGN W/ EXISTING LVL FRAMED ROOF NEW PORCH ROOF EXISTING LVL FRAMED ROOF TO REMAINWorth Noting the net added Rood Area = 311.1 sf and much of the increase in the West WQVC is the result of changing the roof pitches to better manage runoff. NEW + REPLACEMENT FRAMING @ GARAGE VA L L E Y @ F.O.Stud (SE T R A F T E R S @ 9 6 . 1 8 ° OFF V A L L E Y A N G L E ) 5' R E A R Y A R D S E T B A C K DEMO ROOF EXISTING ROOF STRUCTURE TO REMAIN SCALE: 1/4" = 1'-0" 1 ROOF + Drainage A4 08/29/2019 Al Beyer Design Inc. 410 N. Mill B-11 • Aspen, CO 81611 Phone 970.925.8339 • Fax 970.925.8392 Any dimensional descrepancy shall be brought commencement of work. All designs, ideas, arrangements and plans indicated by these drawings and specifications are the property and copyright of the Architect and shall neither be used on any other work nor be used by any other person for any use whatsoever without written permission. Written dimensions shall take precedence over scaled to the attention of the Architect prior to dimensions and shall be verifyed at the job site. CHECKED BY: REVISIONS ISSUE DATE: DRAWN BY: PROJECT NUMBER SHEET TITLE AND NUMBER AB/BK Jenny+James 04/11/19 Prelim Zoning + Smuggler 134 Maple Lane Aspen CO 81611 EXISTING ELEV A5 PID: 273707490134 Hamilton+Foerster 04/04/1987 sq ft 412 sq ft 15 ' A B DC average grade line = 98'-5 1/2" = 7,925.2' Max Roof line = 7,940.2 = 113'-5 1/2 Existing Grade Existing Floor = 7,926.75 = 100'-0DEMO AREA TOTAL AREA DEMO QUICK VIEW: WE ARE KEEPING MOST OF THE EXISTING HOUSE + JUST REPLACING THE REAR AND VISUALLY IT IS EASY TO SEE THIS IS CLEARLY NOT NEARLY >40% DEMO REPLACEKEEP 79 sq ft ABDC average grade line = 98'-5 1/2" = 7,925.2' Max Roof line = 7,940.2 = 113'-5 1/2 Existing Floor = 7,926.75 = 100'-0 12' "standard roof" eave line THIS WALL SHOWN ON NORTH ELEV. DEMO AREA 24.7 sq ft 376.7 sq ft 1 2 3 4 370.1 sq ft 466.7 sq ft 3.9 sq ft 3.5 sq ft 1234 Average grade line = 98'-5 1/2" = 7,925.2' Max Roof line = 7,940.2 = 113'-5 1/2 NOTE: Roof ht. is calculated by Smuggler Park based on 15' above average site grade (those lines shown here) 3 12 12' Above Average Grade Line DEMO AREA TOTAL AREA NOTE: Fill EXTENDED TO ACCOUNT FOR SKEWED VIEW 516.9 sq ft 7- 1 / 2 x 3 - 8 1 / 2 4-3/4x2-6 1/24-3/4x2-6 1/2 7-3/4x2-6 1/2 1 1 2 2 1a 1a 3 3 16 ' 8' 22 ' 14'12'12' 2'5'-55/8" 2'7'-1011/16" 2'-53/16" 5'-515/16" 5'-95/16" 2' 1'-11/4" 45.00° 60.00° 96.18° 66.18° 984.3 sq ft 729.7 sq ft 24 A B D C 1 2 3 4 1 2 3 4 A B D C Existing Membrane roof 1/2:121/2:12 EXISTING LVL FRAMED ROOF TO REMAIN @ F.O.Stud (SE T R A F T E R S @ 9 6 . 1 8 ° OFF V A L L E Y A N G L E ) 5' R E A R Y A R D S E T B A C K DEMO ROOF EXISTING ROOF STRUCTURE TO REMAIN TOTAL LOW ROOFS SCALE: 3/16" = 1'-0" 1 E ELEVATION A5 SCALE: 3/16" = 1'-0" 2 W ELEVATION A5 SCALE: 3/16" = 1'-0" 3 S ELEVATION (1) A5 SCALE: 3/16" = 1'-0" 4 N ELEVATION (1) A5 SCALE: 3/16" = 1'-0" 5 Existing Roof A5 08/29/2019 Al Beyer Design Inc. 410 N. Mill B-11 • Aspen, CO 81611 Phone 970.925.8339 • Fax 970.925.8392 Any dimensional descrepancy shall be brought commencement of work. All designs, ideas, arrangements and plans indicated by these drawings and specifications are the property and copyright of the Architect and shall neither be used on any other work nor be used by any other person for any use whatsoever without written permission. Written dimensions shall take precedence over scaled to the attention of the Architect prior to dimensions and shall be verifyed at the job site. CHECKED BY: REVISIONS ISSUE DATE: DRAWN BY: PROJECT NUMBER SHEET TITLE AND NUMBER AB/BK Jenny+James 04/11/19 Prelim Zoning + Smuggler 134 Maple Lane Aspen CO 81611 ELEVATIONS A6 PID: 273707490134 Hamilton+Foerster 04/04/19 12 ' 3' 15 ' 2321 1234 NEW WOOD SIDING RECESSED METAL SKIRT NEW BR/BATH/GARAGE FORM Average grade line = 98'-5 1/2" = 7,925.2' Max Roof line = 7,940.2 = 113'-5 1/2 NOTE: Roof ht. is calculated by Smuggler Park based on 15' above average site grade (those lines shown here) 3 12 12' Above Average Grade Line 15 ' EXIISTING METAL SIDING A B DC 12 MEMBRANE ROOF 3 123 Repurposed Aluminum Siding average grade line = 98'-5 1/2" = 7,925.2' Max Roof line = 7,940.2 = 113'-5 1/2 Existing Grade Existing Floor = 7,926.75 = 100'-0 NEW WOOD SIDING TOTAL AREA DEMO QUICK VIEW: WE ARE KEEPING MOST OF THE EXISTING HOUSE + JUST REPLACING THE REAR AND VISUALLY IT IS EASY TO SEE THIS IS CLEARLY NOT NEARLY >40% DEMO 3' ± 1 2 3 4 BMP BOAT Recessed Lights NEW SIDING Existing Metal siding Cut-Away shows Stairwell + lower level of retaining New Entry Porch Roof (RDS compliant) wall beyond Recessed Lights 15 ' 1' - 6 1 / 2 " 13 ' - 5 1 / 2 " 6'6'ABDC NEW METAL SIDING "BMP BOAT" average grade line = 98'-5 1/2" = 7,925.2' Max Roof line = 7,940.2 = 113'-5 1/2 Existing Floor = 7,926.75 = 100'-0 12' "standard roof" eave line Fence beyond existing LVL roof to remain NOTE: Roof ht. is calculated by Smuggler Park based on 15' above average site grade (those lines shown here)City of Aspen measures 15' to midpoint of 3:12 sloped roof which the original and current projects easily stay within Lowest Grade @ Bldg =7924.25 Max. Mid Pt. Elev. =7939.25 Project midpoint El = 7938.2 312 3 12MI D . P O I N T MI D . P O I N T H t . Gutter + Downspout No limit to ridge Ht. per City Code. sill = 107'-11 1/2" NEW ROOF Max. Height = 12'-4 NEW WOOD SIDING EXISTING STRUCTURE TO REMAIN EXISTING STICK -BUILT STRUCTURE BATHMECH IN CRAWL SPACE BATH HALL CLOSET LVL ROOF FRAMING IS BAS I S F O R N E W R O O F P L A N E S 3:12 1:12 ± LIGHT WELL GARAGE SKEWED WALLS BEYONDNEW WOOD SIDING 100'-0" T.O. PLY 1 2 3 4 T.O. SLAB 91'-8" Property Line METAL FLASHING INSTALL METAL Z FLASHING -UP WALL 6", OUT OVER FND. INSUL. THEN DOWN TO BELOW GRADE 6" MIN. SCALE: 1/4" = 1'-0" 3 N ELEVATION A6 SCALE: 1/4" = 1'-0" 5 E ELEVATION A6 SCALE: 1/4" = 1'-0" 1 S ELEVATION A6 SCALE: 1/4" = 1'-0" 4 W ELEVATION A6 SCALE: 1/4" = 1'-0" 2 SOUTH SECTION/ELEVATION @ MBR A6 MBR SOUTH WALL BEYOND VIEW FROM MAPLE LANE 08/29/2019