HomeMy WebLinkAboutFile Documents.1001 E Cooper Ave.0078.2018 (12).ARBKEXISTING SIDEWALK
EXISTING SIDEWALK
EXISTING PARKING
EXISTING
TRASH
E. COOPER AVE
UNIT 2 UNIT 3 UNIT 4
UNIT 5 UNIT 6 UNIT 7 UNIT 8
UNIT 1
EXISTING DECK ABOVE
ALLOWABLE FLOOR AREA:
6,782
6,782
72
13,636
s.f.
s.f.
s.f.
s.f.
LOWER LEVEL
UPPER LEVEL
TRASH SHED
TOTAL POSSIBLE
NEIGHBOR
NEIGHBOR
PROPOSED WORK IS ENTIRELY
WITHIN UNIT 1 NO EXTERIOR
WORK IS VISIBLE FORM
STREET OR NEIGHBORING
PROPERTIES
15,000 s.f. TOTAL ALLOWABLE
HATCH INDICATES AREA
INSIDE OF PERIMETER
EXTERIOR WALLS
=6,782 S.F. PER FLOOR
2 FLOORS ALL UNITS
72 S.F.
1,364 s.f. FLOOR AREA AVAILABLE
TO PROPERTY IF ALL
UNITS WERE BUILT-OUT
TO PERIMETER OF
EXTERIOR WALLS
EXISTING SIDEWALK
NORTH
SEE 04-20-09 & 09-24-07 r+b
FLOOR AREA CALCULATION
LETTERS
POSSIBLE FLOOR AREA:
TOTAL POSSIBLE FLOOR AREA
IS LIMITED BY LOCATION OF
EXSTING PERIMETER WALLS
AND EXISTING ROOF
EXISTING CONDITIONS INFORMATION
TAKEN FROM IMPROVEMENT SURVEY
PREPARED BY HIGH COUNTRY
ENGINEERING AND ORIGINAL
CONDOMINIUM PLAT DRAWINGS
827.1 SF
Lower Level Floor Area
827.1 SF
Upper LEvel Floor Area
Scale
Plot Time
matadesign@mac.com
970. 274. 6011.
Project Address:
1001 E Cooper Ave
Aspen, CO
P R O J E C T T E A M:
Architect:
Martin Mata, Architect
Mata Design Company
970-274-6011 matadesign@mac.com
Mdesignmata
company
Owner:
KAHN
Aspen, CO
Legal Description:
Unit 1, The Villager
Townhouse Condominiums
1/8" = 1'-0"
18/03/15 12:55:52 AM
C:
\
U
s
e
r
s
\
M
D
C
-
B
O
X
X
-
1
\
D
r
o
p
b
o
x
\
8
-
K
a
h
n
\
R
E
V
I
T
S
c
h
e
m
e
s
\
1
8
0
3
0
1
K
a
h
n
P
e
rm
i
t
.
r
v
t
A100
Site Plan & Floor
Area Calculations
273718233504
Villager Unit 1
KAHN
14 March, 2018
DRB
Exemption
Parcel ID #
1/8" = 1'-0"1 Site Plan
#Revision DescriptionDate
1/8" = 1'-0"2 Level 1 Proposed
1/8" = 1'-0"3 Level 2 Proposed
Gross Floor Area -Post Development
Area Name Level
827.1 SF Lower Level Floor Area Level 1 Proposed
827.1 SF Upper LEvel Floor Area Level 2 Proposed
1654.3 SF (19.2 s.f. NEW FLOOR AREA)
04/10/2018
Existing Gross Floor Area
Scale
Pl
o
t
Ti
m
e
matadesign@mac.com
970. 274. 6011.
Project Address:
1001 E Cooper Ave
Aspen, CO
P R O J E C T T E A M:
Architect:
Martin Mata, Architect
Mata Design Company
970-274-6011 matadesign@mac.com
Mdesignmata
company
Owner:
KAHN
Aspen, CO
Legal Description:
Unit 1, The Villager
Townhouse Condominiums
12" = 1'-0"
18
/
0
3/
1
5
1
2
:
55
:
5
5
A
M
C:
\
U
s
e
r
s
\
M
D
C
-
B
O
X
X
-
1
\
D
r
o
p
b
o
x
\
8
-
K
a
h
n
\
R
E
V
I
T
S
c
h
e
m
e
s
\
1
8
0
3
0
1
K
a
h
n
P
e
rm
i
t
.
r
v
t
A101
Existing Conditions
Floor Plans
273718233504
Villager Unit 1
KAHN
14 March, 2018
DRB
Exemption
Parcel ID #
#Revision DescriptionDate
04/10/2018
Bedroom 2
Bedroom 3
Entry
Office
Exg Bath 2
Foyer
Stair
EXG C.S.
ACCESS
FURN
UP
DECK ABOVE
10' - 10 1/2"8' - 8 1/2"
3' - 6"
W/D
4'
-
0
"
LI
N
.
12
'
-
4
"
5"
NEW WALLS
EXISTING
WALLS TO
REMAIN
4' - 9 1/2"
W/C
Shower
New Bath 3
Closet
5'
-
0
"
4"
2'
-
6
"
MAIN
ENTRANCE
REMOVE
EXG WALLS
Master Bedroom
Steam Shower
Kitchen Dining Area
Living Area
DN
Stair
Deck
sk
y
l
i
g
h
t
a
b
v
3'
-
6
"
4"
7'
-
1
0
"
Ex'g M.Bath
se
a
t
6'
-
1
1
/
2
"
NEW
WALLS
EXISTING
WALLS TO
REMAIN
Closet
5'
-
0
"
2'
-
1
0
"
sh
e
l
v
e
s
REMOVE
EXG WALLS
Scale
Pl
o
t
Ti
m
e
matadesign@mac.com
970. 274. 6011.
Project Address:
1001 E Cooper Ave
Aspen, CO
P R O J E C T T E A M:
Architect:
Martin Mata, Architect
Mata Design Company
970-274-6011 matadesign@mac.com
Mdesignmata
company
Owner:
KAHN
Aspen, CO
Legal Description:
Unit 1, The Villager
Townhouse Condominiums
1/4" = 1'-0"
18
/
0
3/
1
5
1
2
:
55
:
5
7
A
M
C:
\
U
s
e
r
s
\
M
D
C
-
B
O
X
X
-
1
\
D
r
o
p
b
o
x
\
8
-
K
a
h
n
\
R
E
V
I
T
S
c
h
e
m
e
s
\
1
8
0
3
0
1
K
a
h
n
P
e
rm
i
t
.
r
v
t
A201
Proposed Floor
Plans
273718233504
Villager Unit 1
KAHN
14 March, 2018
DRB
Exemption
Parcel ID #
1/4" = 1'-0"1 Level 1 Proposed
1/4" = 1'-0"2 Level 2 Proposed
SCOPE OF WORK:
ELIMINATE EXISTING ANGLED WALLS IN MASTER & BRM 2
PATCH FLOORS, WALLS, ROOF AS NEEDED
REWORK LIGHTS AND OUTLETS IN BEDROOMS AS REQUIED
1 NEW BATH #3
COMPLETELY REMODELED MASTER BATH & BATH #2
2 NEW CLOSETS
NEW HOT WATER SYSTEM WITH RECIRCULATION LINE
RE-USE EXISTING FURNACE/ REROUTE DUCTS AS REQUIRED
A
B
C
D
E
F
G
H
#Revision DescriptionDate
04/10/2018
P
l
o
t
T
i
m
e
18
/
0
3/
1
5
1
2
:
55
:
5
8
A
M
C:
\
U
s
e
r
s
\
M
D
C
-
B
O
X
X
-
1
\
D
r
o
p
b
o
x
\
8
-
K
a
h
n
\
R
E
V
I
T
S
c
h
e
m
e
s
\
1
8
0
3
0
1
K
a
h
n
P
e
rm
i
t
.
r
v
t
04/10/2018