HomeMy WebLinkAboutFile Documents.203 E Hallam St.0209.2019 (17).ARBK Z-Group Architects, P.C. • 411 East Main Street, Aspen, CO. 81611 • Telephone: 970-925-1832 • Fax: 970-925-1371 September 10, 2019 John Barker City of Aspen Community Development – Resubmission Re: 203 East Hallam John – Per your request, the following is a description of the changes made from the original permit submission and this current submission: The differences between the Permit Set submitted on 08/16/18 and 9/10/19 are as follows for the Architecture Drawings: 1. Modified the location of the roof deck to avoid mechanical equipment. The differences between the Permit Set submitted on 08/16/18 and 9/10/19 are as follows for the Landscape Architecture Drawings: Plan Sheets The areas in red below (water feature and two planters) have been removed. Additional hanging planters on the 42” high fence are proposed on the south west section of fence in the front yard 10/15/2019 Z-Group Architects, P.C. • 411 East Main Street, Aspen, CO. 81611 • Telephone: 970-925-1832 • Fax: 970-925-1371 Snowmelt Plan The area identified in red and magenta below are proposed to be snowmelted. The magenta area is on an existing patio, the red areas were previously not improved. - Detail Sheets and Enlargements L4.01 – There is an additional window of enlargement showing the proposed new hanging planters on the 42” high fence L4.02 – Enlargement of the south east side yard has been added to show additional dimensional detail around the trash enclosure L4.03 – Rooftop Plan Enlargement has been modified in coordination with the architectural layout. A horizontal rain screen has been added to the roof wings, the details of which are in the structural drawings. L5.02 – Detail 1, Rear View Fence Perspective was removed in favor of the more detailed information on L4.02 L5.03 – Detail 1, Planter detail was updated with a toe kick L5.04 – Detail 1, the hot tub now sits on the existing slab vs excavating and sinking the hot tub L5.05 – Detail 2 showing the planters has been removed and detail 2 now shows details for the portable step into the hot tub and the hot tub cover rack L5.06 – Detail 1 – the approved portable fire pit has replaced the Paloform Robata Civil Set Backgrounds updated to reflect the latest landscape plan (no water feature, no planters on side yard) with a drain inlet added next to the hot tub in the pebble area. 10/15/2019 Z-Group Architects, P.C. • 411 East Main Street, Aspen, CO. 81611 • Telephone: 970-925-1832 • Fax: 970-925-1371 Pet turf detail removed fromC1.002 as it was a duplicate of the detail on landscape drawings Lighting Set Backgrounds updated to reflect the latest landscape plan (no water feature, no planters on side yard). The lighting on the latest deck area was revised If you have any additional questions or need further clarification, please contact me. Sincerely, Z-GROUP ARCHITECTS Seth Hmielowski 10/15/2019